#!/usr/bin/env python
"""
Pymodbus Synchronous Server Example to showcase Device Information
--------------------------------------------------------------------------

This server demonstrates the use of Device Information to provide information
to clients about the device. This is part of the MODBUS specification, and
uses the MEI 0x2B 0x0E request / response. This example creates an otherwise
empty server.
"""
# --------------------------------------------------------------------------- # 
# import the various server implementations
# --------------------------------------------------------------------------- # 
from pymodbus.server.sync import StartTcpServer
from pymodbus.server.sync import StartUdpServer
from pymodbus.server.sync import StartSerialServer

from pymodbus.device import ModbusDeviceIdentification
from pymodbus.datastore import ModbusSlaveContext, ModbusServerContext

from pymodbus.transaction import ModbusRtuFramer, ModbusBinaryFramer

# --------------------------------------------------------------------------- #
# import versions of libraries which we will use later on for the example
# --------------------------------------------------------------------------- #
from pymodbus import __version__ as pymodbus_version
from serial import __version__ as pyserial_version

# --------------------------------------------------------------------------- # 
# configure the service logging
# --------------------------------------------------------------------------- # 
import logging
FORMAT = ('%(asctime)-15s %(threadName)-15s'
          ' %(levelname)-8s %(module)-15s:%(lineno)-8s %(message)s')
logging.basicConfig(format=FORMAT)
log = logging.getLogger()
log.setLevel(logging.DEBUG)


def run_server():
    # ----------------------------------------------------------------------- #
    # initialize your data store
    # ----------------------------------------------------------------------- #
    store = ModbusSlaveContext()
    context = ModbusServerContext(slaves=store, single=True)
    
    # ----------------------------------------------------------------------- # 
    # initialize the server information
    # ----------------------------------------------------------------------- # 
    # If you don't set this or any fields, they are defaulted to empty strings.
    # ----------------------------------------------------------------------- # 
    identity = ModbusDeviceIdentification()
    identity.VendorName = 'Pymodbus'
    identity.ProductCode = 'PM'
    identity.VendorUrl = 'http://github.com/riptideio/pymodbus/'
    identity.ProductName = 'Pymodbus Server'
    identity.ModelName = 'Pymodbus Server'
    identity.MajorMinorRevision = '1.5'

    # ----------------------------------------------------------------------- #
    # Add an example which is long enough to force the ReadDeviceInformation
    # request / response to require multiple responses to send back all of the
    # information.
    # ----------------------------------------------------------------------- #

    identity[0x80] = "Lorem ipsum dolor sit amet, consectetur adipiscing " \
                     "elit. Vivamus rhoncus massa turpis, sit amet " \
                     "ultrices orci semper ut. Aliquam tristique sapien in " \
                     "lacus pharetra, in convallis nunc consectetur. Nunc " \
                     "velit elit, vehicula tempus tempus sed. "

    # ----------------------------------------------------------------------- #
    # Add an example with repeated object IDs. The MODBUS specification is
    # entirely silent on whether or not this is allowed. In practice, this
    # should be assumed to be contrary to the MODBUS specification and other
    # clients (other than pymodbus) might behave differently when presented
    # with an object ID occurring twice in the returned information.
    #
    # Use this at your discretion, and at the very least ensure that all
    # objects which share a single object ID can fit together within a single
    # ADU unit. In the case of Modbus RTU, this is about 240 bytes or so. In
    # other words, when the spec says "An object is indivisible, therefore
    # any object must have a size consistent with the size of transaction
    # response", if you use repeated OIDs, apply that rule to the entire
    # grouping of objects with the repeated OID.
    # ----------------------------------------------------------------------- #
    identity[0x81] = ['pymodbus {0}'.format(pymodbus_version),
                      'pyserial {0}'.format(pyserial_version)]

    # ----------------------------------------------------------------------- #
    # run the server you want
    # ----------------------------------------------------------------------- # 
    # Tcp:
    StartTcpServer(context, identity=identity, address=("localhost", 5020))

    # TCP with different framer
    # StartTcpServer(context, identity=identity,
    #                framer=ModbusRtuFramer, address=("0.0.0.0", 5020))

    # Udp:
    # StartUdpServer(context, identity=identity, address=("0.0.0.0", 5020))
    
    # Ascii:
    # StartSerialServer(context, identity=identity,
    #                    port='/dev/ttyp0', timeout=1)
    
    # RTU:
    # StartSerialServer(context, framer=ModbusRtuFramer, identity=identity,
    #                   port='/dev/ttyp0', timeout=.005, baudrate=9600)

    # Binary
    # StartSerialServer(context,
    #                   identity=identity,
    #                   framer=ModbusBinaryFramer,
    #                   port='/dev/ttyp0',
    #                   timeout=1)


if __name__ == "__main__":
    run_server()