1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123
|
.\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.44.1.
.TH MEASURE "1" "September 2014" "spotread" "User Commands"
.SH NAME
Measure \- Read Print Spot values.
.SH DESCRIPTION
Measure spot values, Version 1.6.3
.SH SYNOPSIS
.B spotread
.RB [\-options]\ [logfile]
.TP
\fB\-v\fR
Verbose mode
.TP
\fB\-s\fR
Print spectrum for each reading
.TP
\fB\-S\fR
Plot spectrum for each reading
.TP
\fB\-c\fR listno
Set communication port from the following list (default 1)
.IP
** No ports found **
.TP
\fB\-t\fR
Use transmission measurement mode
.TP
\fB\-e\fR
Use emissive measurement mode (absolute results)
.TP
\fB\-eb\fR
Use display white brightness relative measurement mode
.TP
\fB\-ew\fR
Use display white point relative chromatically adjusted mode
.TP
\fB\-p\fR
Use telephoto measurement mode (absolute results)
.TP
\fB\-pb\fR
Use projector white brightness relative measurement mode
.TP
\fB\-pw\fR
Use projector white point relative chromatically adjusted mode
.TP
\fB\-a\fR
Use ambient measurement mode (absolute results)
.TP
\fB\-f\fR
Use ambient flash measurement mode (absolute results)
.TP
\fB\-I\fR illum
Set simulated instrument illumination using FWA (def \fB\-i\fR illum):
M0, M1, M2, A, C, D50, D50M2, D65, F5, F8, F10 or file.sp]
.TP
\fB\-i\fR illum
Choose illuminant for computation of CIE XYZ from spectral data & FWA:
A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp
.TP
\fB\-Q\fR observ
Choose CIE Observer for spectral data or CCSS instrument:
1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2
(Choose FWA during operation)
.TP
\fB\-F\fR filter
Set filter configuration (if aplicable):
.TP
n
None
.TP
p
Polarising filter
.TP
6
D65
.TP
u
U.V. Cut
.TP
\fB\-E\fR extrafilterfile
Apply extra filter compensation file
.TP
\fB\-x\fR
Display Yxy instead of Lab
.TP
\fB\-h\fR
Display LCh instead of Lab
.TP
\fB\-V\fR
Show running average and std. devation from ref.
.TP
\fB\-T\fR
Display correlated color temperatures and CRI
.TP
\fB\-N\fR
Disable auto calibration of instrument
.TP
\fB\-H\fR
Start in high resolution spectrum mode (if available)
.TP
\fB\-X\fR file.ccmx
Apply Colorimeter Correction Matrix
.TP
\fB\-X\fR file.ccss
Use Colorimeter Calibration Spectral Samples for calibration
.TP
\fB\-Y\fR r|n
Override refresh, non\-refresh display mode
.TP
\fB\-Y\fR R:rate
Override measured refresh rate with rate Hz
.TP
\fB\-Y\fR A
Use non\-adaptive integration time mode (if available).
.TP
\fB\-W\fR n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
.TP
\fB\-D\fR [level]
Print debug diagnostics to stderr
.TP
logfile
Optional file to save reading results as text
|