1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159
|
<!DOCTYPE html PUBLIC "-//w3c//dtd html 4.0 transitional//en">
<html>
<head>
<meta http-equiv="Content-Type" content="text/html;
charset=windows-1252">
<meta http-equiv="content-type" content="text/html;
charset=windows-1252">
<meta name="GENERATOR" content="Mozilla/4.73 [en] (WinNT; I)
[Netscape]">
<title>Argyll XRGA conversion</title>
</head>
<body>
<br>
<h2> <u>Conversion to/from XRGA<br>
</u></h2>
After purchasing Gretag-Macbeth, X-Rite harmonized the subtly
different calibration standards the two companies were using for
their reflective measurement instruments, in order to minimize
changes with the introduction of new instruments. The result was the
<a href="http://www.xrite.com/xrite-graphic-arts-standard">XRGA
standard</a>, introduced in September 2010.<br>
<br>
Current X-Rite instruments are natively calibrated to XRGA, while
older instruments from X-Rite are calibrated to XRDI, and
Gretag-Macbeth instruments to GMDI standards. To smooth the
interchange of old and new instruments, a spectral <a
href="https://www.xrite.com/documents/literature/en/L7-462_XRGA_WhitePaper_en.pdf">conversion
is possible</a> between these different standards. While such a
conversion is not perfect, it reduces the discontinuities between
old instrument families and current X-Rite instruments.<br>
<br>
By default, Argyll will use the native calibration of Gretag-Macbeth
and X-Rite instruments. These are summarized here:<br>
<br>
<table cellspacing="2" cellpadding="2" border="0">
<tbody>
<tr>
<td valign="top"><a href="instruments.html#DTP20">DTP20
"Pulse"</a> <br>
</td>
<td valign="top">XRDI<br>
</td>
</tr>
<tr>
<td valign="top"><a href="instruments.html#DTP22">DTP22
Digital Swatchbook</a></td>
<td valign="top">XRDI<br>
</td>
</tr>
<tr>
<td valign="top"><a href="instruments.html#DTP41">DTP41</a></td>
<td valign="top">XRDI<br>
</td>
</tr>
<tr>
<td valign="top"><a href="instruments.html#dtp51">DTP51</a></td>
<td valign="top">XRDI<br>
</td>
</tr>
<tr>
<td valign="top"> <a href="instruments.html#sl">Spectrolino</a>/
<a href="instruments.html#ss">SpectroScan</a></td>
<td valign="top">GMDI<br>
</td>
</tr>
<tr>
<td valign="top"><a href="instruments.html#i1p">Eye-One Pro</a>
Rev A-D</td>
<td valign="top">GMDI<br>
</td>
</tr>
<tr>
<td valign="top"><a href="instruments.html#ColorMunki"><span
style="text-decoration: underline;">ColorMunki</span></a>
Design, Photo or i1Studio<br>
</td>
<td valign="top">XRGA<br>
</td>
</tr>
<tr>
<td valign="top"><a href="instruments.html#i1p2">Eye-One Pro2</a>
(Eye-One Pro Rev E)</td>
<td valign="top">XRGA<br>
</td>
</tr>
</tbody>
</table>
<br>
<br>
You can override this and force reflective data to be a particular
calibration standard in two ways:<br>
<br>
<a name="A"></a>Using the <b>-A</b> command line option in <a
href="spotread.html#A">spotread</a> and <a
href="chartread.html#A">chartread</a>:<br>
<br>
<b>-A </b>N|A|X|G<br>
<br>
The <b>N</b> argument sets
the calibration to Native.<br>
The <b>A</b> argument sets
the calibration to XRGA.<br>
The <b>X</b> argument sets
the calibration to XRDI.<br>
The <b>G</b> argument sets
the calibration to GMDI.<br>
<br>
<br>
Or by setting an environment variable:<br>
(Note that command line options will override this.)<br>
<br>
<br>
<span style="font-weight: bold;"><a name="ARGYLL_XRGA"></a>ARGYLL_XRGA</span><br>
<br>
<div style="margin-left: 40px;"> If the <span style="font-weight:
bold;">ARGYLL_XRGA </span> environment variable is set to:<br>
<br>
<b>XRGA</b>, then all Getag-MacBeth/X-Rite
reflective measurements will be converted to XRGA.<br>
<b> XRDI</b>, then all Getag-MacBeth/X-Rite
reflective measurements will be converted to XRDI.<br>
<b> GMDI</b>, then all Getag-MacBeth/X-Rite
reflective measurements will be converted to GMDI.<br>
<br>
If not set (or set to some other string), then the native
calibration will be used. Note that the values must be upper case.<br>
</div>
<span style="font-weight: bold;"></span><br>
All of the above except the <b>DTP51</b> can have a conversion
applied. <br>
(The DTP51 returns only colorimetric data, while the conversion
requires spectral data.)<br>
<br>
You can also convert from one standard to the other using <a
href="spec2cie.html#A">spec2cie</a>.<br>
<br>
For informational purposes, the native calibration of some other