File: cs_user_radiative_transfer.h

package info (click to toggle)
code-saturne 5.3.2%2Brepack-1
  • links: PTS, VCS
  • area: main
  • in suites: buster
  • size: 76,868 kB
  • sloc: ansic: 338,582; f90: 118,487; python: 65,227; makefile: 4,429; cpp: 3,826; xml: 3,078; sh: 1,205; lex: 170; yacc: 100
file content (294 lines) | stat: -rw-r--r-- 10,530 bytes parent folder | download
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
/*============================================================================
 * Code_Saturne documentation page
 *============================================================================*/

/*
  This file is part of Code_Saturne, a general-purpose CFD tool.

  Copyright (C) 1998-2018 EDF S.A.

  This program is free software; you can redistribute it and/or modify it under
  the terms of the GNU General Public License as published by the Free Software
  Foundation; either version 2 of the License, or (at your option) any later
  version.

  This program is distributed in the hope that it will be useful, but WITHOUT
  ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS
  FOR A PARTICULAR PURPOSE.  See the GNU General Public License for more
  details.

  You should have received a copy of the GNU General Public License along with
  this program; if not, write to the Free Software Foundation, Inc., 51 Franklin
  Street, Fifth Floor, Boston, MA 02110-1301, USA.
*/

/*----------------------------------------------------------------------------*/

/*!

  \page cs_user_radiative_transfer Examples of data settings for radiative transfers

  \section radiat_activ Activation of the module

  The module can be activated in the \ref usppmo routine in
  \ref cs_user_parameters.f90. The corresponding keyword is \c iirayo in the
  \ref cs_glob_rad_transfer_params structure.

  This member can take the values:
   - \ref radiat::iirayo "iirayo" = 0: module desactivated.
   - \ref radiat::iirayo "iirayo" = 1: the module is activated and the Discrete
                                       Ordinates Method is used.
   - \ref radiat::iirayo "iirayo" = 2: the module is activated and the P1 model
                                       is used.

  \section radiat_param Radiation module specific parameters.

  When the module is activated, its specific input parameters should be set in
  the \ref cs_user_radiative_transfer_parameters function of the
  \ref cs_user_radiative_transfer.c file.

  \section cs_user_radiative_transfer_h_cs_user_radiative_transfer_parameters Calculation options for the radiative transfer module.

  Radiative transfer parameters may be defined using the
  \ref cs_user_radiative_transfer_parameters function.

  \snippet cs_user_radiative_transfer.c cs_user_radiative_transfer_parameters

  \section cs_user_radiative_transfer_h_boundary_conditions Radiative transfer boundary conditions

\image html radiative_tr_sketch.gif "Sketch of thermal flux in boundary walls"


The radiative boundary condition is based on the calculation of a new wall
temperature. This temperature is  computed with a thermal flux balance:

\f[{ Q_{conduction} = Q_{convection} + (Q_{rayt_{absorption}} - Q_{rayt_{emission}}}) \f]

Therefore :

\f[ \dfrac{xlamp}{epap}  (T_{fluid} - T_{wall})
= h_{fluid}  (T_{fluid} - T_{wall}) + epsp  (Q_{incid} - \sigma * T_{wall}) \f]


 \note In \c Code_Saturne the flux is positive when it is oriented from inside to outside.


  |  Body                        |     Emissivity    |
  |------------------------------|------------------:|
  |  polished steel              |       0.06        |
  |  oxidized steel              |       0.80        |
  |  steel rough                 |       0.94        |
  |  polished aluminium          |       0.04        |
  |  oxidiezd aluminium (inside) |       0.09        |
  |  oxidized aluminium (wet air)|       0.90        |
  |  brick                       |       0.93        |
  |  concrete                    |       0.93        |
  |  paper                       |       0.8 to 0.9  |
  |  water                       |       0.96        |


  \subsection bound_faces Boundary faces identification

   Boundary faces may be identified using the \ref getfbr function,
   or preferrably, through boundary zones, defined using the
   GUI or the \ref cs_user_zones function..

\subsection init_fin Initialization and finalization

The following declaration and initialization block needs to be added
for the following examples:

\snippet cs_user_radiative_transfer_bcs.c loc_var

<b> Remaining initialisation</b>

ivar: number of the thermal variable

\snippet cs_user_radiative_transfer_bcs.c ivar

Min and Max values for the wall temperatures (clipping otherwise)

\f$ T_{min} \f$ and \f$T_{max} \f$ are given in Kelvin.

\snippet  cs_user_radiative_transfer_bcs.c temp

\subsection assign2 Assign boundary conditions to boundary wall

\section cs_user_radiative_transfer_bcs_zones  Zone definitions

For each boundary face face_id, a specific output (logging and
postprocessing) zone id may be assigned. This allows realizing balance
sheets by treating them separately for each zone. By default, the
output zone id is set to the general (input) zone id associated to a face.

To access output zone ids (both for reading and modifying), use the
\ref cs_rad_transfer_get_output_b_face_zone_ids function.
The zone id values are arbitrarily chosen by the user, but must be
positive integers; very high numbers may also lead to higher memory
consumption.

\paragraph wall_carac Wall characteristics

\warning The unit of the temperature is the Kelvin

\paragraph manda Mandatory data

  - \c isothp(ifac) boundary face type
              -  \c itpimp -> Gray wall with fixed inside temperature
              -  \c ipgrno -> Gray wall with fixed outside temperature
              -  \c iprefl -> Reflecting wall with fixed outside temperature
              -  \c ifgrno -> Gray wall with fixed conduction flux
              -  \c ifrefl -> Reflecting wall with fixed conduction flux

  - \c tintp(ifac) inside wall temperature (Kelvin)
                   initialize thwall at the first time step.
                   If \c isothp = \c itpimp, the value of thwall is fixed to \c tintp
                   In the other case, \c tintp is only for initialization.
\paragraph data Other data (depending of the isothp)

  - \c rcodcl = conduction flux
  - \c epsp   = emissivity
  - \c xlamp  = conductivity (\f$W.m^{-1}.K^{-1}\f$)
  - \c epap   = thickness (\f$m\f$)
  - \c textp  = outside temperature (\f$K\f$)


\subsection ex Examples of boundary conditions

Here is a list of examples:

  \subsubsection ex1 Gray or black wall with profil of fixed inside temperature

  For wall boundary faces, selection criteria: color 1  \n

  \snippet   cs_user_radiative_transfer_bcs.c  example_1


  \subsubsection ex2 Gray or black wall with fixed outside temperature \f$ T_{ext} \f$

  For wall boundary faces, selection criteria: color 2  \n

  \snippet  cs_user_radiative_transfer_bcs.c example_2


  \subsubsection ex3 Reflecting wall (\f$ epsp = 0 \f$) with fixed outside temperature \f$ T_{ext} \f$

  For wall boundary faces, selection criteria: color 3 \n

  \snippet  cs_user_radiative_transfer_bcs.c example_3


  \subsubsection ex4 Gray or black wall and fixed conduction flux through the wall

For wall boundary faces which have the color 4: \n

\f[
\begin{array}{rcl}
\frac{\texttt{xlamp}}{\texttt{epap}} \cdot (T_{wall} - T_{ext})
&=& \text{fixed conduction flux in } W.m^{-2} \\
&=& \texttt{rodcl(ifac,ivar,3)}
\end{array}
\f]

If the conduction flux is zero then the wall is adiabatic. The array \f$ \texttt{rcodcl(ifac,ivar,3)}\f$ has the value of the flux. \n
Flux density (< 0 if gain for the fluid)
 - For temperature \f$T\f$, in \f$ W.m^{-2}\f$:

 \f[ rcodcl(ifac,ivar,3)=C_p (viscls+\frac{visct}{\sigma})\cdot \grad{T}\cdot \vect{n} \f]

 - For enthalpy \f$h\f$, in \f$ W.m^{-2} \f$:
 \f[ RCODC(IFAC,IVAR,3)=(viscls+\frac{visct}{\sigma})\cdot \grad{H} \cdot \vect{n}\f]

\snippet  cs_user_radiative_transfer_bcs.c example_4


\subsubsection ex5 Reflecting wall and fixed conduction flux through the wall

For wall boundary faces which have the color 5:\n

\f[
\frac{xlamp}{epap} \cdot (T_{wall} - T_{ext}) = \text{fixed conduction flux}
\f]
and \f$ epsp = 0 \f$

If the conduction flux is zero then the wall is adiabatic.
 Flux density (< 0 if gain for the fluid)
  - For temperatures \f$T\f$,    in \f$ W.m^{-2} \f$:
    \f[  rcodcl(ifac,ivar,3) = C_p  (viscls+\frac{visct}{\sigma}) \cdot \grad{T}\cdot \vect{n} \f]
  - For enthalpies \f$h\f$,      in \f$ W.m^{-2} \f$:
    \f[  rcodcl(ifac,ivar,3) =    (viscls+\frac{visct}{\sigma})  \cdot \grad{H} \cdot \vect{n} \f]

\snippet  cs_user_radiative_transfer_bcs.c example_5

\subsubsection w Warning

For all boundary faces that are not wall it is MANDATORY to impose a number of
zone in the array \c izfrdp. For each zone, informations will be displayed in the listing.

\snippet cs_user_radiative_transfer_bcs.c w

Verification that all boundary faces have been treated

\snippet  cs_user_radiative_transfer_bcs.c check

\subsection end_loop End of the loop on the boundary faces

\snippet  cs_user_radiative_transfer_bcs.c end_radiative
\subsection format_radiative_trans Format
\snippet cs_user_radiative_transfer_bcs.c format_radiative

\section abso_flux Absorption coefficient and net radiation flux

The absorption coefficient and the net radiation flux for the radiative module
can be defined in \ref cs_user_radiative_transfer.c through the
\ref cs_user_rad_transfer_absorption
and \ref cs_user_rad_transfer_net_flux subroutines.

\subsection abso Absorption coefficient

The absorption coefficient is defined in \ref cs_user_rad_transfer_absorption.

\subsubsection arg Arguments of cs_user_rad_transfer_absorption

\snippet cs_user_radiative_transfer.c arg_1

\subsubsection var Local variables to be added

\snippet cs_user_radiative_transfer.c loc_var_dec_1

\subsubsection abso_coeff_computation Computation of the absorption coefficient

\snippet cs_user_radiative_transfer.c abso_coeff

\subsubsection format_1 Format

\snippet cs_user_radiative_transfer.c format_1

\subsection cs_user_rad_transfer_net_flux Net radiation flux

The net radiation flux is computed in \ref cs_user_rad_transfer_net_flux.

\subsubsection arg2 Arguments of cs_user_rad_transfer_net_flux

\snippet cs_user_radiative_transfer.c arg_2

\subsubsection var2 Local variables to be added

\snippet cs_user_radiative_transfer.c loc_var_dec_2

\subsubsection init Initialization

At the end of the subroutine, if \c iok is different from zero, some faces
have been forgotten and the calculation stops.

\snippet cs_user_radiative_transfer.c init

\subsubsection net_flux_computation Computation of the net radiation flux

\snippet cs_user_radiative_transfer.c net_flux

\subsubsection format_2 Format