1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196
|
#!/usr/bin/env python
import os, os.path
import sys
import getopt
import dbus, dbus.glib
import gobject
APPLICATION_DBUS_IFACE="org.conduit.Application"
SYNCSET_DBUS_IFACE="org.conduit.SyncSet"
CONDUIT_DBUS_IFACE="org.conduit.Conduit"
EXPORTER_DBUS_IFACE="org.conduit.Exporter"
DATAPROVIDER_DBUS_IFACE="org.conduit.DataProvider"
class Conduit(object):
def __init__(self, start):
self.bus = dbus.SessionBus()
self.loop = gobject.MainLoop()
if start:
self.get_conduit_app()
else:
obj = self.bus.get_object('org.freedesktop.DBus', '/org/freedesktop/DBus')
dbus_iface = dbus.Interface(obj, 'org.freedesktop.DBus')
if dbus_iface.NameHasOwner(APPLICATION_DBUS_IFACE):
self.get_conduit_app()
else:
raise Exception("Could not connect to conduit")
def get_conduit_app(self):
try:
remote_object = self.bus.get_object(APPLICATION_DBUS_IFACE,"/")
self.app = dbus.Interface(remote_object, APPLICATION_DBUS_IFACE)
except dbus.exceptions.DBusException:
raise Exception("Could not connect to conduit")
def list_dataproviders(self):
print "Available Dataproviders"
for dp in self.app.GetAllDataProviders():
print " *\t%s" % dp
def on_sync_progress(self, progress, uids):
print "Synchronization %2.2f%% complete" % (progress*100.0)
def on_sync_completed(self, abort, error, conflict):
if self.deleteConduitWhenFinished:
self.ss.DeleteConduit(self.conduit, dbus_interface=SYNCSET_DBUS_IFACE)
self.loop.quit()
print "Finished"
def do_sync(self):
print "Refreshing"
#and the normal iface to sync
self.conduit.Sync(dbus_interface=CONDUIT_DBUS_IFACE)
self.loop.run()
def sync(self, syncSet, sink, config, files, deleteConduitWhenFinished, twoWay):
#options
self.deleteConduitWhenFinished = deleteConduitWhenFinished
# create dataproviders
if twoWay:
source_path = self.app.GetDataProvider("FolderTwoWay")
else:
source_path = self.app.GetDataProvider("FileSource")
source_obj = self.bus.get_object(DATAPROVIDER_DBUS_IFACE, source_path)
sink_path = self.app.GetDataProvider(sink)
sink_obj = self.bus.get_object(DATAPROVIDER_DBUS_IFACE, sink_path)
self.sink = dbus.Interface(sink_obj, DATAPROVIDER_DBUS_IFACE)
if self.sink.IsPending():
raise Exception("Could not find dataprovider: %s" % sink)
#configure
if config != None:
self.sink.SetConfigurationXml(config)
if not self.sink.IsConfigured(False, twoWay):
self.sink.Configure()
# now create conduit
conduit_path = self.app.BuildConduit (source_path, sink_path)
self.conduit = self.bus.get_object(CONDUIT_DBUS_IFACE, conduit_path)
self.conduit.connect_to_signal("SyncProgress", self.on_sync_progress, dbus_interface=CONDUIT_DBUS_IFACE)
self.conduit.connect_to_signal("SyncCompleted", self.on_sync_completed, dbus_interface=CONDUIT_DBUS_IFACE)
#two way or not?
if twoWay:
self.conduit.EnableTwoWaySync(dbus_interface=CONDUIT_DBUS_IFACE)
#add the data
for f in files:
source_obj.AddData(f, dbus_interface=DATAPROVIDER_DBUS_IFACE)
#add the conduit to the syncset
self.ss = self.bus.get_object(SYNCSET_DBUS_IFACE, syncSet)
self.ss.AddConduit(self.conduit, dbus_interface=SYNCSET_DBUS_IFACE)
self.do_sync()
def usage():
print "Synchronizes files with a conduit dataprovider\n" + \
"Usage:\n\n" + \
"conduit-client -s SinkName [OPTIONS] files...\n\n" + \
"Options:\n\n" + \
" -h, --help Display Help\n" + \
" -c, --sink-configuration XML Configuration for the sink\n" + \
" -k, --keep Dont delete conduit after sync\n" + \
" -l, --list-dataproviders List available dataprovders\n" + \
" -x, --dont-start Dont start conduit (must be running)\n" + \
" -g, --gui Display in GUI\n" + \
" -t, --two-way Twoway Sync"
def error(msg):
print "\nERROR : %s" % msg
################################################################################
# Main
################################################################################
if __name__ == "__main__":
try:
opts, args = getopt.getopt(sys.argv[1:], "s:c:klxgth", ["sink=", "sink-configuration=", "keep", "list-dataproviders", "dont-start", "gui", "two-way", "help"])
except getopt.GetoptError:
usage()
sys.exit(1)
#Defaults
sinkName = None
sinkConfig = None
gui = False
keep = False
listDps = False
startConduit = True
syncSetPath = "/syncset/dbus"
twoWay = False
for o, a in opts:
if o in ("-s", "--sink"):
sinkName = a
if o in ("-c", "--sink-configuration"):
sinkConfig = a
if o in ("-k", "--keep"):
keep = True
if o in ("-l", "--list-dataproviders"):
listDps = True
if o in ("-x", "--dont-start"):
startConduit = False
if o in ("-g", "--gui"):
syncSetPath = "/syncset/gui"
if o in ("-t", "--two-way"):
twoWay = True
if o in ("-h", "--help"):
usage()
sys.exit()
if not listDps:
if None in [sinkName]:
usage()
error("Please specify all compulsory arguments")
sys.exit(1)
files = []
for a in args:
path = os.path.abspath(a)
if os.path.exists(path):
files.append(os.path.expanduser(path))
if len(files) == 0:
usage()
error("Please specify files to sync")
sys.exit(1)
if twoWay:
if len(files) == 1 and os.path.isdir(files[0]):
pass
else:
usage()
error("Twoway sync expects a folder as its only argument")
sys.exit(1)
#Connect to conduit
try:
conduit = Conduit(start=startConduit)
if listDps == True:
conduit.list_dataproviders()
sys.exit()
else:
conduit.sync(
syncSet=syncSetPath,
sink=sinkName,
config=sinkConfig,
files=files,
deleteConduitWhenFinished=not keep,
twoWay=twoWay
)
except Exception, err:
error(err.message)
sys.exit(1)
|