1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244
|
CHANGES-1.6.txt
---------------
CHANGES IN CUPS V1.6.4
- Removed some duplicate size definitions for some ISO sizes that were
causing problems (<rdar://problem/14722721>)
- The IPP backend did not add the "last-document" attribute
(<rdar://problem/114660379>)
- Added a SyncOnClose directive to cups-files.conf to force cupsd to
call fsync before closing any configuration/state files it writes
(<rdar://problem/14523043>)
- Added USB quirk rule for Lexmark E238 (<rdar://problem/14493054>)
- Closed server connections were still not always detected
(<rdar://problem/14484313>)
- The libusb-based USB backend now loads its list of quirks from files
in /usr/share/cups/usb instead of using a hardcoded table
(<rdar://problem/14442769>)
- The scheduler did not properly register ICC color profiles with
colord (<rdar://problem/14455625>)
CHANGES IN CUPS V1.6.3
- The configure script now prefers Clang over GCC.
- Fixed a compile problem on AIX (STR #4307)
- The default IPP version did not always get set before creating a new
IPP request message (<rdar://problem/14401718>)
- The lp, lpq, lpr, and lpstat now display an error message advising the
use of the /version=1.1 ServerName option (<rdar://problem/14290628>)
- Added documentation about the /version=1.1 option to ServerName in
client.conf (<rdar://problem/14216262>)
- httpStatus(HTTP_ERROR) did not return a useful error message
(<rdar://problem/14217326>)
- The lp, lpq, lpr, and lpstat commands incorrectly ignored the default
printer set in the lpoptions file (<rdar://problem/14216472>)
- Fixed a URI encoding issue for hostnames containing the ` (backquote)
character (<rdar://problem/14243133>)
- Added support for RFC 6874's IPv6 link local address format in URIs
(<rdar://problem/13979453>)
- The USB backend could crash on libusb-based systems if USB was
disabled in the BIOS (<rdar://problem/13875729>)
- Fixed a rounding error in the PWG media size mapping code
(<rdar://problem/13493241>)
- Fixed several ipptool test files that used old STATUS names.
- Kerberos credentials could get truncated when printing to a shared
printer.
- Printing using "ipps" URIs was not encrypted.
- Insecure ICC profiles prevented installation of user profiles for a
printer on OS X.
- Added more USB quirks for the libusb-based backend (STR #4311,
<rdar://problem/13736470>)
- The Russian web interface templates were broken (STR #4310)
- The scheduler no longer tries to do Kerberos authentication over the
loopback interface.
- The IPP backend could fail to pause a job for authentication
(STR #4298)
- Fixed a regression on the handling of auth keys on OS X if the
cups-files.conf was not present or did not contain a SystemAuthKey
value.
- The scheduler incorrectly did a reverse lookup of the server address
when HostNameLookups was turned off (STR #4302)
- The scheduler incorrectly computed the final content type value when
null filters were present.
CHANGES IN CUPS V1.6.2
- Documentation fixes (STR #4229, STR #4239, STR #4234, STR #4248,
STR #4259)
- Security: All file, directory, user, and group settings are now stored
in a separate cups-files.conf configuration file that cannot be set
through the CUPS web interface or APIs (STR #4223)
- Added a Czech localization (STR #4201)
- Added a French localization (STR #4247)
- Added a Russian localization (STR #4228, STR #4285)
- Updated the Catalan localization (STR #4202)
- Local certificate authentication did not guard against an empty
certification file (STR #4293)
- The scheduler did not reject device URIs with spaces.
- Added USB quirk rule for Epson Stylus Photo 750 (STR #4286)
- The IPP backend could crash if the printer disconnects early
(STR #4284)
- cupsGetPPD did not work with statically-configured CUPS shared
queues (STR #4178)
- The scheduler did not support long MIME media types (STR #4270)
- The cupsfilter command did not set the CHARSET environment variable
for the text filters (STR #4273)
- The lp command did not show errors for unknown "--foo" (STR #4261)
- Bad IPP responses could crash ipptool (STR #4262)
- Updated USB quirk rules for Canon and Xerox printers (STR #4217,
STR #4263)
- Added USB blacklisting for printers that require a custom backend
(STR #4218)
- The PPD compiler did not correctly JCL options (STR #4115, STR #4203)
- The ipptool program now supports DEFINE-MATCH and DEFINE-NO-MATCH
predicates for STATUS directives.
- Fixed a problem with local Kerberos authentication (STR #4140)
- Coverity scan: fixed some minor issues (STR #4242)
- The scheduler did not remove color profiles after deleting a printer
(STR #4232, STR #4276)
- The CUPS library did not always detect a timed out connection to the
server which could cause temporary loss of printing from applications
(STR #4187)
- The ipptool program now supports variable substitution in OPERATION
and DELAY directives (STR #4175)
- The IPP backend now stops queues when the server configuration
prevents successful job submission (STR #4125)
- The XML output of ipptool contained empty dictionaries (STR #4136)
- The scheduler did not delete job control backup files (STR #4244)
- cupsGetPPD3 could return a local PPD instead of the correct remote
PPD.
- The scheduler incorrectly advertised auth-info-required for local
queues needing local authentication (STR #4205)
- CUPS 1.6 clients using the ServerName directive in client.conf did not
work with CUPS 1.3.x or older servers (STR #4231, STR #4291)
- The SNMP backend now tries to work around broken printers that use a
newline to separate key/value pairs.
- The IPP backend did not send a cancel request to printers when a job
was canceled and the printer did not support Create-Job.
- Fixed EPM packaging files (STR #4199)
- OpenBSD build fix (STR #4195, STR #4196, STR #4197)
- The scheduler could crash when using Avahi (STR #4183, STR #4192,
STR #4200, STR #4213)
- The IPP backend could get stuck in an endless loop on certain network
errors (STR #4194)
- 32-bit builds failed on Debian (STR #4133)
- The scheduler no longer accepts or sends job description attributes.
- The IPP backend now works around some conformance issues for broken
printers (STR #4190)
- cupsBackendReport() now filters out all control characters from the
reported 1284 device IDs (STR #4124)
- The scheduler no longer allows job-name values that are not valid
network Unicode strings (STR #4072)
- The web interface did not preserve the order of classes, jobs, or
printers (STR #4170)
- The network backends now support disabling of SNMP supply level
queries via the "snmp" URI option (STR #4106)
- The IPP backend did not specify the compression used (STR #4181)
- ipptool did not support octetString values.
- The scheduler did not recognize dnssd: or ipps: URIs as Bonjour shared
queues (STR #4158)
- Applications could not get the PPD file for statically-configured
Bonjour-shared print queues (STR #4159)
- The cupsd.conf file included obsolete browsing directives (STR #4157)
- Fixed a USB backend compatibility issue on systems using libusb
(STR #4155, STR #4191)
- Some Bonjour features were not available on systems with Avahi
(STR #4156)
- CUPS now includes the port number in the Host: header for HTTP
requests.
- Fixed REPEAT-MATCH for STATUS and EXPECT - was incorrectly erroring
out.
CHANGES IN CUPS V1.6.1
- Documentation fix (STR #4149)
- RPM packaging fixes (STR #4129, #4145)
- The Japanese and English web interface headers were swapped
(STR #4148)
CHANGES IN CUPS V1.6.0
- Document changes (STR #4131)
- Added new Catalan (STR #4107) and Spanish (STR #4137) localizations.
CHANGES IN CUPS V1.6rc1
- Added a new Japanese localization (STR #4122)
- The SNMP backend no longer exits if it is unable to obtain an IPv6
socket (STR #4109)
- The LPD backend incorrectly used "localhost" in the control file
instead of the current hostname.
CHANGES IN CUPS V1.6b1
- Documentation updates (STR #3927, STR #3980, STR #4010, STR #4068)
- The scheduler now consolidates all PPD updates from filters at the
end of the job (STR #4075)
- CUPS now supports color management using colord (STR #3808)
- CUPS now supports Bonjour using Avahi (STR #3066)
- The PreserveJobFiles and PreserveJobHistory directives now support
specification of a time interval (STR #3143)
- PPD files can now be archived in (gzip'd) tar files to further reduce
the disk space used by PPD files (STR #3772)
- The network backends now deal with printers that report their levels
in percent but do not specify a maximum capacity of 100 (STR #3551)
- The network backends now report full/almost-full waste bins in
printers along with end-of-life for cleaning pads (STR #4017)
- Added a configure option to set the permissions of the installed
cupsd (STR #3459)
- Added a new WITH-ALL-VALUES directive to ipptool EXPECT predicates
(STR #3949)
- CUPS now supports a User directive in client.conf and the CUPS_USER
environment variable for overriding the default username (STR #3114)
- Now set the PJL USERNAME variable as needed (STR #3100)
- Added support for usernames and passwords longer than 32 characters
(STR #2856)
- Added a new MaxHoldTime directive to automatically cancel jobs that
have been held indefinitely after a specific number of seconds
(STR #2291)
- The LPD backend now uses the originating host name when it is not the
local system (STR #2053)
- CUPS now prefers the suffix "dpcm" when reporting resolution in dots-
per-centimeter (STR #4006)
- The configure script and build system no longer support building of
separate 32-bit and 64-bit libraries.
- The "brightness", "columns", "fitplot", "gamma", "hue",
"natural-scaling", "penwidth", "position", "ppi", "saturation", and
"scaling" options are not longer supported (STR #4010)
- The "page-bottom", "page-left", "page-right", "page-top",
"prettyprint", and "wrap" options have been deprecated (STR #4010)
- The scheduler now reports the standard "number-of-documents" attribute
instead of the CUPS-specific "document-count" attribute in
job objects.
- Added new destination connection and enumeration functions (STR #3924)
- Added new option, localization, and job submission functions that do
not depend on PPD files (STR #3925)
- Added a new MaxJobTime directive for cupsd that specifies the maximum
amount of time allowed for a job to complete before it is canceled.
- The default password callback now supports passwords up to 127
characters.
- The scheduler now supports a DefaultAuthType of "auto" to
automatically choose between Basic (username/password) and Negotiate
(Kerberos) authentication.
- cupsSideChannelSNMPGet/Walk now support OIDs and values up to 64k in
length.
- CUPS no longer supports automatic remote printers or implicit classes
via the CUPS, LDAP, or SLP protocols (STR #3922, STR #3923)
- The PPD APIs are now deprecated and will be removed in a future
version of CUPS (STR #3927)
- The default IPP version for requests is now 2.0 (STR #3929)
- The IPP APIs no longer expose the ipp_t or ipp_attribute_t structures
and instead provide accessor functions (STR #3928)
- The scheduler will no longer run programs with group write permission.
- The PHP module has been removed (STR #3932)
- The bannertops, commandtoescpx, commandtopclx, imagetops,
imagetoraster, pdftops, rastertoescpx, rastertopclx, and texttops
filters have been removed (STR #3930)
- The serial and parallel backends have been removed (STR 3935)
|