1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383
|
% DLT.CONF(5)
# NAME
**dlt.conf** - DLT daemon configuration file
# DESCRIPTION
The DLT daemon is the central application which gathers logs and traces from different applications, stores them temporarily or permanently and transfers them to a DLT client application, which could run directly on the COVESA system or more likely on some external tester device.
The configuration file dlt.conf allows one to configure the different
runtime behaviour of the dlt-daemon. It is loaded during startup of dlt-daemon.
# GENERAL OPTIONS
## Verbose
Start daemon in debug mode, so that all internal debug information is printed out on the console.
Default: Off
## Daemonize
If set to 1 DLT daemon is started in background as daemon. This option is only needed in System V init systems. In systemd based startup systems the daemon is started by spawning own process.
Default: 0
## SendSerialHeader
If set to 1 DLT daemon sends each DLT message to the client with prepanding the serial header "DLS0x01".
Default: 0
## SendContextRegistration
If set to 1 each context which is registered from an application in the DLT daemon generates a message to inform the DLT client about the new context.
Default: 1
## SendMessageTime
If set to 1 DLt daemon sends each second a DLT control message to the client with the current timestamp from the system.
Default: 0
## ECUId
This value sets the ECU Id, which is sent with each DLT message.
Default: ECU1
## SharedMemorySize
This value sets the size of the shared memory, which is used to exchange DLT messages between applications and daemon. This value is defined in bytes. If this value is changed the system must be rebooted to take effect.
Default: 100000
## PersistanceStoragePath
This is the directory path, where the DLT daemon stores its runtime configuration. Runtime configuration includes stored log levels, trace status and changed logging mode.
Default: /tmp
## LoggingMode
The logging console for internal logging of dlt-daemon. 0 = log to stdout, 1 = log to syslog, 2 = log to file (see LoggingFilename), 3 = log to stderr
Default: 0
## LoggingLevel
The internal log level, up to which logs are written. LOG_EMERG = 0, LOG_ALERT = 1, LOG_CRIT = 2, LOG_ERR = 3, LOG_WARNING = 4, LOG_NOTICE = 5, LOG_INFO = 6, LOG_DEBUG = 7
Default: 6
## LoggingFilename
If LoggingMode is set to 2 logs are written to the file path given here.
Default: /tmp/dlt.log
## EnableLoggingFileLimit
Only relevant for logging in file (LoggingMode = 2).
If EnableLoggingFileLimit is set to 0, the daemon logs to one logging file without any size limit.
If EnableLoggingFileLimit is set to 1, the daemon considers the size limits configured by LoggingFileSize and LoggingFileMaxSize. If the limits are configured accordingly, multiple log files are used.
Default: 0
## LoggingFileSize
Only considered for logging in file (LoggingMode = 2) and EnableLoggingFileLimit = 1. Maximum size in bytes of one logging file.
Default: 250000
## LoggingFileMaxSize
Only considered for logging in file (LoggingMode = 2) and EnableLoggingFileLimit = 1. Maximum size in bytes of all logging files.
Default: 1000000
## TimeOutOnSend
Socket timeout in seconds for sending to clients.
Default: 4
## RingbufferMinSize
The minimum size of the Ringbuffer, used for storing temporary DLT messages, until client is connected.
Default: 500000
## RingbufferMaxSize
The max size of the Ringbuffer, used for storing temporary DLT messages, until client is connected.
Default: 10000000
## RingbufferStepSize
The step size the Ringbuffer is increased, used for storing temporary DLT messages, until client is connected.
Default: 500000
## Daemon FIFOSize
The size of Daemon FIFO (MinSize: depend on pagesize of system, MaxSize: please check `/proc/sys/fs/pipe-max-size`)
This is only supported for Linux.
Default: 65536
## ContextLogLevel
Initial log-level that is sent when an application registers. DLT_LOG_OFF = 0, DLT_LOG_FATAL = 1, DLT_LOG_ERROR = 2, DLT_LOG_WARN = 3, DLT_LOG_INFO = 4, DLT_LOG_DEBUG = 5, DLT_LOG_VERBOSE = 6
Default: 4
## ContextTraceStatus
Initial trace-status that is sent when an application registers. DLT_TRACE_STATUS_OFF = 0, DLT_TRACE_STATUS_ON = 1
Default: 0
## ForceContextLogLevelAndTraceStatus
Force log level and trace status of contexts to not exceed "ContextLogLevel" and "ContextTraceStatus". If set to 1 (ON) whenever a context registers or changes the log-level it has to be lower or equal to ContextLogLevel.
Default: 0
## InjectionMode
If set to 0, the injection mode (see [here](./dlt_for_developers.md#DLT-Injection-Messages)) is disabled.
Default: 1
# GATEWAY CONFIGURATION
## GatewayMode
Enable Gateway mode
Default: 0
## GatewayConfigFile
Read gateway configuration from another location
Default: /etc/dlt_gateway.conf
# Permission configuration
DLT daemon runs with e.g.
User: covesa_dlt
Group: covesa_dlt
DLT user applications run with different user and group than dlt-daemon but with supplimentory group: dlt_user_apps_group
<basedir>/dlt FIFO will be created by dlt-daemon with
User: covesa_dlt
Group: dlt_user_apps_group
Permission: 620
so that only dlt-daemon can read and only processes in dlt_user_apps_group can write.
<basedir>/dltpipes will be created by dlt-daemon with
User: covesa_dlt
Group: covesa_dlt
Permission: 3733 (i.e Sticky bit and SGID turned on)
<basedir>/dltpipes/dlt<PID> FIFO will be created by dlt application (user lib) with
User: <user of the application>
Group: covesa_dlt (inherited from <basedir>dltpipes/ due to SGID)
Permission: 620
Thus DLT user applications (and also or attackers) can create the dlt<PID> FIFO
(for communication from dlt-daemon to DLT user application) under <basedir>/dltpipes/. Since sticky bit is set the applications who creates the FIFO can only rename/delete it.
Since SGID of <basedir>/dltpipes is set the group of dlt<PID> FIFO will be covesa_dlt which enables dlt daemon to have write permission on all the dlt<PID> FIFO.
One dlt user application cannot access dlt<PID> FIFO created by other dlt user application(if they run with different user).
Owner group of daemon FIFO directory(Default: /tmp/dlt) (If not set, primary group of dlt-daemon process is used).
Application should have write permission to this group for tracing into dlt. For this opton to work, dlt-daemon should have this group in it's supplementary group.
## DaemonFifoGroup
Owner group of daemon FIFO directory
(If not set, primary group of dlt-daemon process is used)
Application should have write permission to this group for tracing into dlt
For this opton to work, dlt-daemon should have this group in it's Supplementary group
Default: group of dlt-daemon process (/tmp/dlt)
# CONTROL APPLICATION OPTIONS
## ControlSocketPath
Path to control socket.
Default: /tmp/dlt-ctrl.sock
# OFFLINE TRACE OPTIONS
## OfflineTraceDirectory
Store DLT messages to local directory, if not set offline Trace is off.
Default: /tmp
## OfflineTraceFileSize
This value defines the max size of a offline trace file, if offline trace is enabled. This value is defined in bytes. If the files size of the current used log file is exceeded, a new log file is created.
Default: 1000000
## OfflineTraceMaxSize
This value defines the max offline Trace memory size, if offline trace is enabled. This value is defined in bytes. If the overall offline trace size is exceeded, the oldest log files are deleted, until a new trace file fits the overall offline trace max size.
Default: 4000000
## OfflineTraceFileNameTimestampBased
Filename timestamp based or index based. 1 = timestamp based, 0 = index based
Default: Function is disabled
# LOCAL CONSOLE OUTPUT OPTIONS
## PrintASCII
Prints each received DLT message from the application in ASCII to the local console. This option should only be anabled for debugging purpose.
Default: Function is disabled
## PrintHex
Prints each received DLT message from the application in ASCII to the local console. The payload is printed in Hex. This option should only be anabled for debugging purpose.
Default: Function is disabled
## PrintHeadersOnly
Prints each received DLT message from the application in ASCII to the local console. Only the header is printed. This option should only be anabled for debugging purpose.
Default: Function is disabled
# SERIAL CLIENT OPTIONS
## RS232DeviceName
If this value is set to a serial device name, e.g. /dev/ttyS0, a serial port is used for logging to a client.
Default: Serial port for logging is disabled
## RS232Baudrate
The used serial baud rate, if serial logging is enabled. The RS232DeviceName must be set to enable serial logging.
Default: 115200
## RS232SyncSerialHeader
If serial logging is enabled, each received DLT message is checked to contain a serial header. If the DLT message contains no serial header, the message is ignored.
Default: Function is disabled
# TCP CLIENT OPTIONS
## TCPSyncSerialHeader
Each received DLT message on a TCP connection is checked to contain a serial header. If the DLT message contains no serial header, the message is ignored.
Default: Function is disabled
# ECU SOFTWARE VERSION OPTIONS
## SendECUSoftwareVersion
Periodically send ECU version info. 0 = disabled, 1 = enabled
Default: Function is disabled
# PathToECUSoftwareVersion
Absolute path to file storing version information - if disabled the DLT version will be send.
Default: Function is disabled.
# TIMEZONE INFO OPTIONS
# SendTimezone
Periodically send timezone info. 0 = disabled, 1 = enabled
Default: Function is disabled
# OFFLINE LOGSTORAGE OPTIONS
## OfflineLogstorageMaxDevices
Maximum devices to be used as offline logstorage devices. 0 = disabled, 1 .. DLT_OFFLINE_LOGSTORAGE_MAX_DEVICES
Default: 0 (Function is disabled)
## OfflineLogstorageDirPath
Path to store DLT offline log storage messages.
Default: off
## OfflineLogstorageTimestamp
Appends timestamp in log file name. 0 = disabled, 1 = enabled
Default: 0
## OfflineLogstorageDelimiter
Appends delimiter in log file name, only punctuation characters allowed.
Default: _
## OfflineLogstorageMaxCounter
Wrap around value for log file count in file name.
Default: UINT_MAX
## OfflineLogstorageCacheSize
Maximal used memory for log storage cache in KB.
Default: 30000 KB
## UDPConnectionSetup
Enable or disable UDP connection. 0 = disabled, 1 = enabled
## UDPMulticastIPAddress
The address on which daemon multicasts the log messages
## UDPMulticastIPPort
The Multicase IP port. Default: 3491
# AUTHOR
Alexander Wenzel (alexander.aw.wenzel (at) bmw (dot) de)
# COPYRIGHT
Copyright (C) 2015 BMW AG. License MPL-2.0: Mozilla Public License version 2.0 <http://mozilla.org/MPL/2.0/>.
# BUGS
See Github issue: <https://github.com/COVESA/dlt-daemon/issues>
# SEE ALSO
**dlt-daemon(1)**, **dlt-system(1)**
|