1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2876 2877 2878 2879 2880 2881 2882 2883 2884 2885 2886 2887 2888 2889 2890 2891 2892 2893 2894 2895 2896 2897 2898 2899 2900 2901 2902 2903 2904 2905 2906 2907 2908 2909 2910 2911 2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923 2924 2925 2926 2927 2928 2929 2930 2931 2932 2933 2934 2935 2936 2937 2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981 2982 2983 2984 2985 2986 2987 2988 2989 2990 2991 2992 2993 2994 2995 2996 2997 2998 2999 3000 3001 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3013 3014 3015 3016 3017 3018 3019 3020 3021 3022 3023 3024 3025 3026 3027 3028 3029 3030 3031 3032 3033 3034 3035 3036 3037 3038 3039 3040 3041 3042 3043 3044 3045 3046 3047 3048 3049 3050 3051 3052 3053 3054 3055 3056 3057 3058 3059 3060 3061 3062 3063 3064 3065 3066 3067 3068 3069 3070 3071 3072 3073 3074 3075 3076 3077 3078 3079 3080 3081 3082 3083 3084 3085 3086 3087 3088 3089 3090 3091 3092 3093 3094 3095 3096 3097 3098 3099 3100 3101 3102 3103 3104 3105 3106 3107 3108 3109 3110 3111 3112 3113 3114 3115 3116 3117 3118 3119 3120 3121 3122 3123 3124 3125 3126 3127 3128 3129 3130 3131 3132 3133 3134 3135 3136 3137 3138 3139 3140 3141 3142 3143 3144 3145 3146 3147 3148 3149 3150 3151 3152 3153 3154 3155 3156 3157 3158 3159 3160 3161 3162 3163 3164 3165 3166 3167 3168 3169 3170 3171 3172 3173 3174 3175 3176 3177 3178 3179 3180 3181 3182 3183 3184 3185 3186 3187 3188 3189 3190 3191 3192 3193 3194 3195 3196 3197 3198 3199 3200 3201 3202 3203 3204 3205 3206 3207 3208 3209 3210 3211 3212 3213 3214 3215 3216 3217 3218 3219 3220 3221 3222 3223 3224 3225 3226 3227 3228 3229 3230 3231 3232 3233 3234 3235 3236 3237 3238 3239 3240 3241 3242 3243 3244 3245 3246 3247 3248 3249 3250 3251 3252 3253 3254 3255 3256 3257 3258 3259 3260 3261 3262 3263 3264 3265 3266 3267 3268 3269 3270 3271 3272 3273 3274 3275 3276 3277 3278 3279 3280 3281 3282 3283 3284 3285 3286 3287 3288 3289 3290 3291 3292 3293 3294 3295 3296 3297 3298 3299 3300 3301 3302 3303 3304 3305 3306 3307 3308 3309 3310 3311 3312 3313 3314 3315 3316 3317 3318 3319 3320 3321 3322 3323 3324 3325 3326 3327 3328 3329 3330 3331 3332 3333 3334 3335 3336 3337 3338 3339 3340 3341 3342 3343 3344 3345 3346 3347 3348 3349 3350 3351 3352 3353 3354 3355 3356 3357 3358 3359 3360 3361 3362 3363 3364 3365 3366 3367 3368 3369 3370 3371 3372 3373 3374 3375 3376 3377 3378 3379 3380 3381 3382 3383 3384 3385 3386 3387 3388 3389 3390 3391 3392 3393 3394 3395 3396 3397 3398 3399 3400 3401 3402 3403 3404 3405 3406 3407 3408 3409 3410 3411 3412 3413 3414 3415 3416 3417 3418 3419 3420 3421 3422 3423 3424 3425 3426 3427 3428 3429 3430 3431 3432 3433 3434 3435 3436 3437 3438 3439 3440 3441 3442 3443 3444 3445 3446 3447 3448 3449 3450 3451 3452 3453 3454 3455 3456 3457 3458 3459 3460 3461 3462 3463 3464 3465 3466 3467 3468 3469 3470 3471 3472 3473 3474 3475 3476 3477 3478 3479 3480 3481 3482 3483 3484 3485 3486 3487 3488 3489 3490 3491 3492 3493 3494 3495 3496 3497 3498 3499 3500 3501 3502 3503 3504 3505 3506 3507 3508 3509 3510 3511 3512 3513 3514 3515 3516 3517 3518 3519 3520 3521 3522 3523 3524 3525 3526 3527 3528 3529 3530 3531 3532 3533 3534 3535 3536 3537 3538 3539 3540 3541 3542 3543 3544 3545 3546 3547 3548 3549 3550 3551 3552 3553 3554 3555 3556 3557 3558 3559 3560 3561 3562 3563 3564 3565 3566 3567 3568 3569 3570 3571 3572 3573 3574 3575 3576 3577 3578 3579 3580 3581 3582 3583 3584 3585 3586 3587 3588 3589 3590 3591 3592 3593 3594 3595 3596 3597 3598 3599 3600 3601 3602 3603 3604 3605 3606 3607 3608 3609 3610 3611 3612 3613 3614 3615 3616 3617 3618 3619 3620 3621 3622 3623 3624 3625 3626 3627 3628 3629 3630 3631 3632 3633 3634 3635 3636 3637 3638 3639 3640 3641 3642 3643 3644 3645 3646 3647 3648 3649 3650 3651 3652 3653 3654 3655 3656 3657 3658 3659 3660 3661 3662 3663 3664 3665 3666 3667 3668 3669 3670 3671 3672 3673 3674 3675 3676 3677 3678 3679 3680 3681 3682 3683 3684 3685 3686 3687 3688 3689 3690 3691 3692 3693 3694 3695 3696 3697 3698 3699 3700 3701 3702 3703 3704 3705 3706 3707 3708 3709 3710 3711 3712 3713 3714 3715 3716 3717 3718 3719 3720 3721 3722 3723 3724 3725 3726 3727 3728 3729 3730 3731 3732 3733 3734 3735 3736 3737 3738 3739 3740 3741 3742 3743 3744 3745 3746 3747 3748 3749 3750 3751 3752 3753 3754 3755 3756 3757 3758 3759 3760 3761 3762 3763 3764 3765 3766 3767 3768 3769 3770 3771 3772 3773 3774 3775 3776 3777 3778 3779 3780 3781 3782 3783 3784 3785 3786 3787 3788 3789 3790 3791 3792 3793 3794 3795 3796 3797 3798 3799 3800 3801 3802 3803 3804 3805 3806 3807 3808 3809 3810 3811 3812 3813 3814 3815 3816 3817 3818 3819 3820 3821 3822 3823 3824 3825 3826 3827 3828 3829 3830 3831 3832 3833 3834 3835 3836 3837 3838 3839 3840 3841 3842 3843 3844 3845 3846 3847 3848 3849 3850 3851 3852 3853 3854 3855 3856 3857 3858 3859 3860 3861 3862 3863 3864 3865 3866 3867 3868 3869 3870 3871 3872 3873 3874 3875 3876 3877 3878 3879 3880 3881 3882 3883 3884 3885 3886 3887 3888 3889 3890 3891 3892 3893 3894 3895 3896 3897 3898 3899 3900 3901 3902 3903 3904 3905 3906 3907 3908 3909 3910 3911 3912 3913 3914 3915 3916 3917 3918 3919 3920 3921 3922 3923 3924 3925 3926 3927 3928 3929 3930 3931 3932 3933 3934 3935 3936 3937 3938 3939 3940 3941 3942 3943 3944 3945 3946 3947 3948 3949 3950 3951 3952 3953 3954 3955 3956 3957 3958 3959 3960 3961 3962 3963 3964 3965 3966 3967 3968 3969 3970 3971 3972 3973 3974 3975 3976 3977 3978 3979 3980 3981 3982 3983 3984 3985 3986 3987 3988 3989 3990 3991 3992 3993 3994 3995 3996 3997 3998 3999 4000 4001 4002 4003 4004 4005 4006 4007 4008 4009 4010 4011 4012 4013 4014 4015 4016 4017 4018 4019 4020 4021 4022 4023 4024 4025 4026 4027 4028 4029 4030 4031 4032 4033 4034 4035 4036 4037 4038 4039 4040 4041 4042 4043 4044 4045 4046 4047 4048 4049 4050 4051 4052 4053 4054 4055 4056 4057 4058 4059 4060 4061 4062 4063 4064 4065 4066 4067 4068 4069 4070 4071 4072 4073 4074 4075 4076 4077 4078 4079 4080 4081 4082 4083 4084 4085 4086 4087 4088 4089 4090 4091 4092 4093 4094 4095 4096 4097 4098 4099 4100 4101 4102 4103 4104 4105 4106 4107 4108 4109 4110 4111 4112 4113 4114 4115 4116 4117 4118 4119 4120 4121 4122 4123 4124 4125 4126 4127 4128 4129 4130 4131 4132 4133 4134 4135 4136 4137 4138 4139 4140 4141 4142 4143 4144 4145 4146 4147 4148 4149 4150 4151 4152 4153 4154 4155 4156 4157 4158 4159 4160 4161 4162 4163 4164 4165 4166 4167 4168 4169 4170 4171 4172 4173 4174 4175 4176 4177 4178 4179 4180 4181 4182 4183 4184 4185 4186 4187 4188 4189 4190 4191 4192 4193 4194 4195 4196 4197 4198 4199 4200 4201 4202 4203 4204 4205 4206 4207 4208 4209 4210 4211 4212 4213 4214 4215 4216 4217 4218 4219 4220 4221 4222 4223 4224 4225 4226 4227 4228 4229 4230 4231 4232 4233 4234 4235 4236 4237 4238 4239 4240 4241 4242 4243 4244 4245 4246 4247 4248 4249 4250 4251 4252 4253 4254 4255 4256 4257 4258 4259
|
Network Working Group K. Rehbehn
Request for Comments: 2954 Megisto Systems
Obsoletes: 1604 D. Fowler
Category: Standards Track Syndesis Limited
October 2000
Definitions of Managed Objects
for Frame Relay Service
Status of this Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
Copyright (C) The Internet Society (2000). All Rights Reserved.
Abstract
This memo defines an extension to the Management Information Base
(MIB) for use with network management protocols in Transmission
Control Protocol/Internet Protocol-based (TCP/IP) internets. In
particular, it defines objects for managing the frame relay service.
This document obsoletes RFC 1604.
Table of Contents
1 The SNMP Management Framework ................................ 2
2 Overview ..................................................... 3
2.1 Scope of MIB ............................................... 3
2.2 Transiting Multiple Frame Relay Networks ................... 5
2.3 Access Control ............................................. 5
2.4 Frame Relay Service MIB Terminology ........................ 6
2.5 Relation to Other MIBs ..................................... 8
2.5.1 System Group ............................................. 8
2.5.2 Interfaces Table (ifTable, ifXtable) ..................... 8
2.5.3 Stack Table for DS1/E1 Environment ....................... 12
2.5.4 Stack Table for V.35 Environments ........................ 14
2.5.5 The Frame Relay/ATM PVC Service Interworking MIB ......... 14
2.6 Textual Convention Change .................................. 15
3 Object Definitions ........................................... 15
3.1 The Frame Relay Service Logical Port ....................... 17
Rehbehn & Fowler Standards Track [Page 1]
RFC 2954 Frame Relay Service MIB October 2000
3.2 Frame Relay Management VC Signaling ........................ 22
3.3 Frame Relay PVC End-Points ................................. 32
3.4 Frame Relay PVC Connections ................................ 45
3.5 Frame Relay Accounting ..................................... 53
3.6 Frame Relay Network Service Notifications .................. 56
3.7 Conformance Information .................................... 57
4 Acknowledgments .............................................. 67
5 References ................................................... 67
6 Security Considerations ...................................... 69
7 Authors' Addresses ........................................... 70
APPENDIX A Update Information .................................. 71
Intellectual Property Rights ................................... 75
Full Copyright Statement ....................................... 76
1. The SNMP Management Framework
The SNMP Management Framework presently consists of five major
components:
o An overall architecture, described in RFC 2571 [1].
o Mechanisms for describing and naming objects and events for the
purpose of management. The first version of this Structure of
Management Information (SMI) is called SMIv1 and described in STD
16, RFC 1155 [2], STD 16, RFC 1212 [3] and RFC 1215 [4]. The
second version, called SMIv2, is described in STD 58, RFC 2578
[5], STD 58, RFC 2579 [6] and STD 58, RFC 2580 [7].
o Message protocols for transferring management information. The
first version of the SNMP message protocol is called SNMPv1 and
described in STD 15, RFC 1157 [8]. A second version of the SNMP
message protocol, which is not an Internet standards track
protocol, is called SNMPv2c and described in RFC 1901 [9] and RFC
1906 [10]. The third version of the message protocol is called
SNMPv3 and described in RFC 1906 [10], RFC 2572 [11] and RFC 2574
[12].
o Protocol operations for accessing management information. The
first set of protocol operations and associated PDU formats is
described in STD 15, RFC 1157 [8]. A second set of protocol
operations and associated PDU formats is described in RFC 1905
[13].
o A set of fundamental applications described in RFC 2573 [14] and
the view-based access control mechanism described in RFC 2575
[15].
Rehbehn & Fowler Standards Track [Page 2]
RFC 2954 Frame Relay Service MIB October 2000
A more detailed introduction to the current SNMP Management Framework
can be found in RFC 2570 [16].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. Objects in the MIB are
defined using the mechanisms defined in the SMI.
This memo specifies a MIB module that is compliant to the SMIv2. A
MIB conforming to the SMIv1 can be produced through the appropriate
translations. The resulting translated MIB must be semantically
equivalent, except where objects or events are omitted because no
translation is possible (use of Counter64). Some machine readable
information in SMIv2 will be converted into textual descriptions in
SMIv1 during the translation process. However, this loss of machine
readable information is not considered to change the semantics of the
MIB.
2. Overview
These objects are used to manage a frame relay Service. At present,
this applies to the following value of the ifType variable in the
IF-MIB [26]:
frameRelayService (44)
This section provides an overview and background of how to use this
MIB and other potential MIBs to manage a frame relay service.
2.1. Scope of MIB
The Frame Relay Service MIB supports Customer Network Management
(CNM) of a frame relay network service. Through the use of this and
other related MIBs, a frame relay service customer's NMS can monitor
the customer's UNI/NNI logical ports and PVCs. It provides customers
with access to configuration data, performance monitoring
information, and fault detection for the delivered frame relay
service. As an option, an SNMP agent supporting the Frame Relay
Service MIB may allow customer-initiated PVC management operations
such as creation, deletion, modification, activation, and
deactivation of individual PVCs. However, internal aspects of the
network (e.g., switching elements, line cards, and network routing
tables) are beyond the scope of this MIB.
The Frame Relay Service MIB models all interfaces and PVCs delivered
by a frame relay service within a single virtual SNMP system for the
purpose of comprehensively representing the customer's frame relay
service. The customer's interfaces and PVCs may physically exist on
one or more devices within the network topology. An SNMP agent
Rehbehn & Fowler Standards Track [Page 3]
RFC 2954 Frame Relay Service MIB October 2000
providing support for the Frame Relay Service MIB as well as other
appropriate MIBs to model a single virtual frame relay network
service is referred to as a Frame Relay Service (FRS) agent.
Internal communication mechanisms between the FRS agent and
individual devices within the frame relay network delivering the
service are implementation specific and beyond the scope of this MIB.
The customer's NMS will typically access the SNMP agent implementing
the Frame Relay Service MIB over a frame relay permanent virtual
connection (PVC). SNMP access over a frame relay PVC is achieved
through the use of SNMP over UDP over IP encapsulated in Frame Relay
according to STD 55, RFC2427 and ITU X.36 Annex D [23]. Alternate
access mechanisms and SNMP agent implementations are possible.
This MIB will NOT be implemented on user equipment (e.g., DTE). Such
devices are managed using the Frame Relay DTE MIB (RFC2115[18]).
However, concentrators may use the Frame Relay Service MIB instead of
the Frame Relay DTE MIB.
This MIB does not define managed objects for the physical layer.
Existing physical layer MIBs (e.g., DS1 MIB) and Interface MIB will
be used as needed in FRS Agent implementations.
This MIB supports frame relay PVCs. This MIB may be extended at a
later time to handle frame relay SVCs.
A switch implementation may support this MIB for the purpose of
configuration and control of the frame relay service beyond the scope
of traditional customer network management applications. A number of
objects (e.g. frLportTypeAdmin) support administrative actions that
impact the operation of frame relay switch equipment in the network.
This is reflected in the differences between the two MIB compliance
modules:
o the frame relay service compliance module
(frnetservCompliance), and
o the frame relay switch compliance module
(frnetSwitchCompliance).
The frame relay service compliance module does not support the
administrative control objects used for switch management.
Rehbehn & Fowler Standards Track [Page 4]
RFC 2954 Frame Relay Service MIB October 2000
2.2. Transiting Multiple Frame Relay Networks
This MIB is only used to manage a single frame relay service offering
from one network service provider. Therefore, if a customer PVC
traverses multiple networks, then the customer must poll a different
FRS agent within each frame relay network to retrieve the end-to-end
view of service.
Figure 1 illustrates a customer ("User B") NMS accessing FRS agents
in three different frame relay networks (I, J, and K).
+-------------------------------------+
| Customer Network Management Station |
| (SNMP based) |
+-------------------------------------+
^ ^ ^
| | |
| | |
UNI | NNI | NNI | UNI
| ^ | ^ | ^
| +-----------+ | +-----------+ | +-----------+ |
| | | | | | | | | |
Originating | | FR | | | FR | | | FR | |Terminating
+--------+ | | Network I | | | Network J | | | Network K | | +--------+
| | | | | | | | | | | | | |
| |---| |---| |---| |---| User B |
| | | | | | | | | | | | | |
| //////////////////////////////////////////////////////////// |
| | | | | | | | | | | | | |
+--------+ | +-----------+ | +-----------+ | +-----------+ | +--------+
| | | |
| | | |
| PVC Segment 1 | PVC Segment 2 | PVC Segment 3 |
|<------------->|<------------->|<------------->|
| |
| Multi-network PVC |
|<--------------------------------------------->|
| NNI = Network-to Network Interface |
UNI = User-to-Network Interface
Figure 1, Multi-network PVC
2.3. Access Control
A frame relay network is shared amongst many frame relay subscribers.
Each subscriber will only have access to their information (e.g.,
information with respect to their interfaces and PVCs). The FRS agent
should provide instance level granularity for MIB views.
Rehbehn & Fowler Standards Track [Page 5]
RFC 2954 Frame Relay Service MIB October 2000
2.4. Frame Relay Service MIB Terminology
Access Channel - An access channel generically refers to the DS1/E1
or DS3/E3-based UNI access channel or NNI access channel across which
frame relay data transits. An access channel is the access pathway
for a single stream of user data.
Within a given DS1 line, an access channel can denote any one of the
following:
o Unchannelized DS1 - the entire DS1 line is considered an access
channel. Each access channel is comprised of 24 DS0 time slots.
o Channelized DS1 - an access channel is any one of 24 channels.
Each access channel is comprised of a single DS0 time slot.
o Fractional DS1 - an access channel is a grouping of NxDS0 time
slots (NX56/64 Kbps, where N = 1-23 DS0 Time slots per Fractional
DS1 Access Channel) that may be assigned in consecutive or
non-consecutive order.
Within a given E1 line, a channel can denote any one of the following:
o Unchannelized E1 - the entire E1 line is considered a single
access channel. Each access channel is comprised of 31 E1 time
slots.
o Channelized E1 - an access channel is any one of 31 channels.
Each access channel is comprised of a single E1 time slot.
o Fractional E1 - an access channel is a grouping of N E1 time
slots (NX64 Kbps, where N = 1-30 E1 time slots per FE1 access
channel) that may be assigned in consecutive or non-consecutive
order.
Within a given unformatted line, the entire unformatted line is
considered an access channel. Examples include RS-232, V.35, V.36 and
X.21 (non-switched), and unframed E1 (G.703 without G.704).
Access Rate - The data rate of the access channel, expressed in
bits/second. The speed of the user access channel determines how
rapidly the end user can inject data into the network.
Bc - The Committed Burst Size (Bc) is the maximum amount of
subscriber data (expressed in bits) that the network agrees to
transfer, under normal conditions, during a time interval Tc.
Rehbehn & Fowler Standards Track [Page 6]
RFC 2954 Frame Relay Service MIB October 2000
Be - The Excess Burst Size (Be) is the maximum amount of subscriber
data (expressed in bits) in excess of Bc that the network will
attempt to deliver during the time interval Tc. This data (Be) is
delivered in general with a lower probability than Bc.
CIR - The Committed Information Rate (CIR) is the subscriber data
rate (expressed in bits/second) that the network commits to deliver
under normal network conditions. CIR is averaged over the time
interval Tc (CIR = Bc/Tc).
DLCI - Data Link Connection Identifier
Logical Port - This term is used to model the frame relay "interface"
on a device.
NNI - Network to Network Interface
Permanent Virtual Connection (PVC) - A virtual connection that has
its end-points and bearer capabilities defined at subscription time.
Time slot (E1) - An octet within the 256-bit information field in
each E1 frame is defined as a time slot. Time slots are position
sensitive within the 256-bit information field. Fractional E1 service
is provided in contiguous or non-contiguous time slot increments.
Time slot (DS0) - An octet within the 192-bit information field in
each DS1 frame is defined as a time slot. Time slots are position
sensitive within the 192-bit information field. Fractional DS1
service is provided in contiguous or non-contiguous time slot
increments.
UNI - User to Network Interface
N391 - Full status (status of all PVCs) polling counter
N392 - Error threshold
N393 - Monitored events count
T391 - Link integrity verification polling timer
T392 - Polling verification timer
nT3 - Status enquiry timer
nN3 - Maximum status enquiry counter
Rehbehn & Fowler Standards Track [Page 7]
RFC 2954 Frame Relay Service MIB October 2000
2.5. Relation to Other MIBs
2.5.1. System Group
Use the System Group of the SNMPv2-MIB [27] to describe the Frame
Relay Service (FRS) agent. The FRS agent may be monitoring many
frame relay devices in one network. The System Group does not
describe frame relay devices monitored by the FRS agent.
sysDescr: ASCII string describing the FRS agent.
Can be up to 255 characters long. This field is
generally used to indicate the network providers
identification and type of service offered.
sysObjectID: Unique OBJECT IDENTIFIER (OID) for the
FRS agent.
sysUpTime: Clock in the FRS agent; TimeTicks
in 1/100s of a second. Elapsed type since
the FRS agent came on line.
sysContact: Contact for the FRS agent.
ASCII string of up to 255 characters.
sysName: Domain name of the FRS agent, for example,
acme.com
sysLocation: Location of the FRS agent.
ASCII string of up to 255 characters.
sysServices: Services of the managed device. The value "2",
which implies that
the frame relay network is providing
a subnetwork level service, is recommended.
2.5.2. Interfaces Table (ifTable, ifXtable)
This specifies how the Interfaces Group defined in the IF MIB [26]
shall be used for the management of frame relay based interfaces, and
in conjunction with the Frame Relay Service MIB module. This memo
assumes the interpretation of the evolution of the Interfaces group
to be in accordance with: "The interfaces table (ifTable) contains
information on the managed resource's interfaces. Each sub-layer
below the internetwork layer of a network interface is considered an
interface." Thus, the ifTable allows the following frame relay-based
interfaces to be represented as table entries:
Rehbehn & Fowler Standards Track [Page 8]
RFC 2954 Frame Relay Service MIB October 2000
- Frame relay interfaces in equipment (e.g., switches, routers or
networks) supporting frame relay. This level is concerned with
generic frame counts and not with individual virtual connections.
In accordance with the guidelines of ifTable, frame counts per
virtual connection are not covered by ifTable, and are considered
interface specific and covered in the Frame Relay Service MIB module.
In order to interrelate the ifEntries properly, the Interfaces Stack
Group shall be supported.
Some specific interpretations of ifTable for frame relay follow.
Object Use for the generic Frame Relay layer
====== =============================================
ifIndex Each frame relay port is represented by an
ifEntry.
ifDescr Description of the frame relay interface.
ASCII string describing the UNI/NNI logical
port. Can be up to 255 characters long.
ifType The value allocated for Frame Relay Service
is equal to 44.
ifMtu Set to maximum frame size in octets for this
frame relay logical port.
ifSpeed Peak bandwidth in bits per second available
for use. This could be the speed of the
logical port and not the access rate. Actual
user information transfer rate (i.e., access
rate) of the UNI or NNI logical port in bits
per second (this is not the clocking speed).
For example, it is 1,536,000 bits per second
for a DS1-based UNI/NNI logical port and
1,984,000 bits per second for an E1-based
UNI/NNI logical port.
ifPhysAddress The primary address for this logical port
assigned by the frame relay interface
provider. An octet string of zero length if
no address is used for this logical port.
ifAdminStatus The desired administrative status of the
frame relay logical port.
Rehbehn & Fowler Standards Track [Page 9]
RFC 2954 Frame Relay Service MIB October 2000
ifOperStatus The current operational status of the Frame
Relay UNI or NNI logical port.
ifLastChange The value of sysUptime at the last
re-initialization of the logical port. The
value of sysUpTime at the time the logical
port entered its current operational state.
If the current state was entered prior to the
last re-initialization of the local network
management subsystem, then this object
contains a zero value.
ifInOctets The number of received octets. This counter
only counts octets from the beginning of the
frame relay header field to the end of user
data.
ifInUcastPkts The number of received unerrored, unicast
frames.
ifInDiscards The number of received frames discarded.
Specifically, frames discarded due to ingress
buffer congestion and traffic policing.
ifInErrors The number of received frames that are
discarded because of an error. Specifically,
frames that are too long or too short, frames
that are not a multiple of 8 bits in length,
frames with an invalid or unrecognized DLCI,
frames with an abort sequence, frames with
improper flag delimitation, and frame that
fail FCS.
ifInUnknownProtos The number of packets discarded because of an
unknown or unsupported protocol. For Frame
Relay Service interfaces, this counter will
always be zero.
ifOutOctets The number of transmitted octets. This
counter only counts octets from the beginning
of the frame relay header field to the end of
user data.
ifOutUcastpkts The number of unerrored, unicast frames sent.
ifOutDiscards The number of frames discarded in the egress
direction. Possible reasons are as follows:
policing, congestion.
Rehbehn & Fowler Standards Track [Page 10]
RFC 2954 Frame Relay Service MIB October 2000
ifOutErrors The number of frames discarded in the egress
direction because of an error. Specifically,
frames that are aborted due to a transmitter
underrun.
ifName This variable is not applicable for Frame
Relay Service interfaces, therefore, this
variable contains a zero-length string.
ifInMulticastPkts The number of received unerrored, multicast
frames.
ifInBroadcastPkts This variable is not applicable for Frame
Relay Service interfaces, therefore, this
counter is always zero.
ifOutMulticastPkts The number of sent unerrored, multicast
frames.
ifOutBroadcastPkts This variable is not applicable for Frame
Relay Service interfaces, therefore, this
counter is always zero.
ifHCInOctets Only used for DS3-based (and greater) Frame
Relay logical ports. The number of received
octets. This counter only counts octets
from the beginning of the frame relay header
field to the end of user data.
ifHCOutOctets Only used for DS3-based (and greater) Frame
Relay logical ports. The number of
transmitted octets. This counter only counts
octets from the beginning of the frame relay
header field to the end of user data.
ifLinkUpDownTrapEnable Set to true(1). It is recommended that the
underlying physical layer notifications be
disabled since both are not required.
Notifications are enabled at the frame relay
service layer specifically because PVC
notifications are not to be sent if the frame
relay interface fails. Without a
linkUp/linkDown notification, the management
station would receive no notification of the
failure.
Rehbehn & Fowler Standards Track [Page 11]
RFC 2954 Frame Relay Service MIB October 2000
ifHighSpeed Set to the user data rate of the frame relay
logical port in millions of bits per second.
If the user data rate is less than 1 Mbps,
then this value is zero.
ifPromiscuousMode Set to false(2).
ifConnectorPresent Set to false(2).
Frame relay network service interfaces support the Interface Stack
Group. Frame relay network service interfaces do not support any
other groups or objects in the Interfaces group of the IF MIB.
2.5.3. Stack Table for DS1/E1 Environment
This section describes by example how to use ifStackTable to
represent the relationship of frame relay service to ds0 and
ds0Bundles with ds1 interfaces [20].
Example: A frame relay service is being carried on 4 ds0s of a ds1.
+---------------------+
| Frame Relay Service |
+---------------------+
|
+---------------------+
| ds0Bundle |
+---------------------+
| | | |
+---+ +---+ +---+ +---+
|ds0| |ds0| |ds0| |ds0|
+---+ +---+ +---+ +---+
| | | |
+---------------------+
| ds1 |
+---------------------+
The assignment of the index values could for example be:
ifIndex Description
1 FrameRelayService (type 44)
2 ds0Bundle (type 82)
3 ds0 #1 (type 81)
4 ds0 #2 (type 81)
5 ds0 #3 (type 81)
6 ds0 #4 (type 81)
7 ds1 (type 18)
Rehbehn & Fowler Standards Track [Page 12]
RFC 2954 Frame Relay Service MIB October 2000
The ifStackTable is then used to show the relationships between the
various interfaces.
ifStackTable Entries
HigherLayer LowerLayer
0 1
1 2
2 3
2 4
2 5
2 6
3 7
4 7
5 7
6 7
7 0
In the case where the frame relay service is using a single ds0, then
the ds0Bundle is not required.
+---------------------+
| Frame Relay Service |
+---------------------+
|
+---+
|ds0|
+---+
|
+---------------------+
| ds1 |
+---------------------+
The assignment of the index values could for example be:
ifIndex Description
1 FrameRelayService (type 44)
2 ds0 (type 81)
3 ds1 (type 18)
The ifStackTable is then used to show the relationships between the
various interfaces.
Rehbehn & Fowler Standards Track [Page 13]
RFC 2954 Frame Relay Service MIB October 2000
ifStackTable Entries
HigherLayer LowerLayer
0 1
1 2
2 3
3 0
2.5.4. Stack Table for V.35 Environments
This section describes by example how to use ifStackTable to
represent the relationship of frame relay service with V.35
interfaces.
+---------------------+
| Frame Relay Service |
+---------------------+
|
+---------------------+
| v35 |
+---------------------+
An example of index values in this case could be:
ifIndex Description
1 FrameRelayService (type 44)
2 v35 (type 33)
Note type 33 (RS232-like MIB) is used instead of type 45 (V.35). V35
does not pertain to this environment.
The ifStackTable is then used to show the relationships between the
various interfaces.
ifStackTable Entries
HigherLayer LowerLayer
0 1
1 2
2 0
2.5.5. The Frame Relay/ATM PVC Service Interworking MIB
Connections between two frame relay endpoints are represented with an
entry in the frPVCConnectTable of this MIB. Both endpoints are
represented with rows in the frPVCEndptTable. The
frPVCEndptConnectIdentifier object of each endpoint points to the
frPVCConnectTable cross-connect table row for the connection.
Rehbehn & Fowler Standards Track [Page 14]
RFC 2954 Frame Relay Service MIB October 2000
In contrast, a connection that spans frame relay and ATM endpoints is
represented with an entry in the frAtmIwfConnectionTable of the
FR/ATM PVC Service Interworking MIB defined in [28].
In the case of an inter-worked connection, the
frPVCEndptConnectIdentifier object is set to zero. Instead, the
frPVCEndptAtmIwfConnIndex object is set to the index of the FR/ATM
IWF cross-connect table row.
The frame relay PVC cross-connect table (frPVCConnectTable) does not
contain an entry for the FR/ATM inter-worked connection.
2.6. Textual Convention Change
Version 1 of the Frame Relay Service MIB contains MIB objects defined
with the DisplayString textual convention. In version 2 of this MIB,
the syntax for these objects has been updated to use the (now
preferred) SnmpAdminString textual convention. The new TC provides
support for a greater variety of international character sets.
The working group realizes that this change is not strictly supported
by SMIv2. In our judgment, the alternative of deprecating the old
objects and defining new objects would have a more adverse impact on
backward compatibility and interoperability, given the particular
semantics of these objects.
3. Object Definitions
FRNETSERV-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE, transmission,
Counter32, Integer32 FROM SNMPv2-SMI
TimeStamp, RowStatus FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
InterfaceIndex, ifIndex FROM IF-MIB
SnmpAdminString FROM SNMP-FRAMEWORK-MIB;
frnetservMIB MODULE-IDENTITY
LAST-UPDATED "200009280000Z" -- September 28, 2000
ORGANIZATION "IETF Frame Relay Service MIB Working Group"
CONTACT-INFO
"WG Charter:
http://www.ietf.org/html.charters/frnetmib-charter
WG-email:
frnetmib@sunroof.eng.sun.com
Rehbehn & Fowler Standards Track [Page 15]
RFC 2954 Frame Relay Service MIB October 2000
Subscribe:
frnetmib-request@sunroof.eng.sun.com
Email Archive:
ftp://ftp.ietf.org/ietf-mail-archive/frnetmib
Chair: Andy Malis
Vivace Networks, Inc.
Email: Andy.Malis@vivacenetworks.com
WG editor: Kenneth Rehbehn
Megisto Systems, Inc.
Email: krehbehn@megisto.com
Co-author: David Fowler
Syndesis Limited,
EMail: fowler@syndesis.com"
DESCRIPTION
"The MIB module to describe generic objects for
Frame Relay Network Service."
--
-- Revision History
--
REVISION "200009280000Z"
DESCRIPTION
"Published as RFC 2954.
The major new features of this revision include:
o Support for read-write capability to
provision switch components providing service,
o Support for cross-connection via a frame relay
to ATM service interworking function,
o Support for frame relay fragmentation,
o Additional frame counters to track frame
loss.
Refer to Appendix A for a comprehensive list of
changes since RFC 1604."
REVISION "199311161200Z"
DESCRIPTION
"Published as RFC 1604."
::= { transmission 44 }
Rehbehn & Fowler Standards Track [Page 16]
RFC 2954 Frame Relay Service MIB October 2000
frnetservObjects
OBJECT IDENTIFIER ::= { frnetservMIB 1 }
frnetservTraps
OBJECT IDENTIFIER ::= { frnetservMIB 2 }
frnetservTrapsPrefix
OBJECT IDENTIFIER ::= { frnetservTraps 0 }
--
-- The Frame Relay Service Logical Port
--
frLportTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrLportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Logical Port Information table is
an interface-specific addendum to the generic
ifTable of the Interface MIB."
::= { frnetservObjects 1 }
frLportEntry OBJECT-TYPE
SYNTAX FrLportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay Logical Port
Information table."
INDEX { ifIndex }
::= { frLportTable 1 }
FrLportEntry ::=
SEQUENCE {
frLportNumPlan INTEGER,
frLportContact SnmpAdminString,
frLportLocation SnmpAdminString,
frLportType INTEGER,
frLportAddrDLCILen INTEGER,
frLportVCSigProtocol INTEGER,
frLportVCSigPointer OBJECT IDENTIFIER,
frLportDLCIIndexValue Integer32,
frLportTypeAdmin INTEGER,
frLportVCSigProtocolAdmin INTEGER,
frLportFragControl INTEGER,
frLportFragSize Integer32
}
Rehbehn & Fowler Standards Track [Page 17]
RFC 2954 Frame Relay Service MIB October 2000
frLportNumPlan OBJECT-TYPE
SYNTAX INTEGER {
other(1),
e164(2),
x121(3),
none(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the network
address numbering plan for this UNI/NNI logical
port. The network address is the object
ifPhysAddress. The value none(4) implies that
there is no ifPhysAddress. The FRS agent will
return an octet string of zero length for
ifPhysAddress. The value other(1) means that an
address has been assigned to this interface, but
the numbering plan is not enumerated here."
REFERENCE "E.164 [29]
X.121 [30]"
::= { frLportEntry 1 }
frLportContact OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the network
contact for this UNI/NNI logical port."
::= { frLportEntry 2 }
frLportLocation OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the frame
relay network location for this UNI/NNI logical
port."
::= { frLportEntry 3 }
frLportType OBJECT-TYPE
SYNTAX INTEGER {
uni(1),
nni(2)
}
MAX-ACCESS read-only
Rehbehn & Fowler Standards Track [Page 18]
RFC 2954 Frame Relay Service MIB October 2000
STATUS current
DESCRIPTION
"The value of this object identifies the type of
network interface for this logical port."
::= { frLportEntry 4 }
frLportAddrDLCILen OBJECT-TYPE
SYNTAX INTEGER {
twoOctets10Bits(1),
threeOctets10Bits(2),
threeOctets16Bits(3),
fourOctets17Bits(4),
fourOctets23Bits(5)
}
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Q.922
Address field length and DLCI length for this
UNI/NNI logical port."
REFERENCE "Q.922 [25]"
::= { frLportEntry 5 }
frLportVCSigProtocol OBJECT-TYPE
SYNTAX INTEGER {
none(1),
lmi(2),
ansiT1617D(3),
ansiT1617B(4),
ccittQ933A(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Local
In-Channel Signaling Protocol that is used for
this frame relay UNI/NNI logical port.
none(1): Interface does not use a PVC
signaling protocol
lmi(2): Interface operates the Stratacom/
Nortel/DEC Local Management
Interface Specification protocol
ansiT1617D(3): Interface operates the ANSI T1.617
Annex D PVC status protocol
Rehbehn & Fowler Standards Track [Page 19]
RFC 2954 Frame Relay Service MIB October 2000
ansiT1617B(4): Interface operates the ANSI
T1.617
Annex B procedures
ccittQ933A(5): Interface operates the ITU Q.933
Annex A PVC status protocol"
REFERENCE "LMI [24]
T1.617 Annex D [17],
Q.933 Annex A [22]"
::= { frLportEntry 6 }
frLportVCSigPointer OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The value of this object is used as a pointer to
the table that contains the Local In-Channel
Signaling Protocol parameters and errors for this
UNI/NNI logical port.
This object has been deprecated to reflect the
fact that the local in-channel signaling
parameters are accessed from a single table
(frMgtVCSigTable) that includes parameters for all
possible signaling protocols. Early design
anticipated multiple tables, one for each
signaling protocol."
::= { frLportEntry 7 }
frLportDLCIIndexValue OBJECT-TYPE
SYNTAX Integer32 (16..4194303)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains a hint to be used for
frPVCEndptDLCIIndex when creating entries in the
frPVCEndptTable. The SYNTAX of this object
matches the SYNTAX of the frPVCEndptDLCIIndex - an
object that is restricted to legal Q.922 DLCI
values for the size of the address field.
The value 0 indicates that no unassigned entries
are available.
To obtain the frPVCEndptDLCIIndex value for a new
entry, the manager issues a management protocol
retrieval operation to obtain the current value of
Rehbehn & Fowler Standards Track [Page 20]
RFC 2954 Frame Relay Service MIB October 2000
this object. After each retrieval, the agent must
modify the value to the next unassigned index to
prevent assignment of the same value to multiple
management systems.
A management system should repeat the read to
obtain a new value should an attempt to create the
new row using the previously returned hint fail."
REFERENCE "Q.922 [25]"
::= { frLportEntry 8 }
frLportTypeAdmin OBJECT-TYPE
SYNTAX INTEGER {
uni(1),
nni(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object desired identifies the
type of network interface for this logical port."
::= { frLportEntry 9 }
frLportVCSigProtocolAdmin OBJECT-TYPE
SYNTAX INTEGER {
none(1),
lmi(2),
ansiT1617D(3),
ansiT1617B(4),
ccittQ933A(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
Local In-Channel Signaling Protocol that is used
for this frame relay UNI/NNI logical port. This
value must be made the active protocol as soon as
possible on the device.
Refer to frLportVCSigProtocol for a description of
each signaling protocol choices."
REFERENCE "LMI [24]
T1.617 Annex D [17],
Q.933 Annex A [22]"
::= { frLportEntry 10 }
frLportFragControl OBJECT-TYPE
Rehbehn & Fowler Standards Track [Page 21]
RFC 2954 Frame Relay Service MIB October 2000
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the transmission and
reception of fragmentation frames for this UNI or
NNI interface.
on(1) Frames are fragmented using the interface
fragmentation format
Note: The customer side of the interface
must also be configured to fragment
frames.
off(2) Frames are not fragmented using the
interface fragmentation format."
REFERENCE "FRF.12 [21]"
DEFVAL { off }
::= { frLportEntry 11 }
frLportFragSize OBJECT-TYPE
SYNTAX Integer32 (0..4096)
UNITS "Octets"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object is the size in octets of
the maximum size of each fragment to be sent when
fragmenting. This object is only used by the
fragmentation transmitter, and the two sides of
the interface may differ. The fragment size
includes the octets for the frame relay header,
the UI octet, the NLPID, the fragmentation header,
and the fragment payload. If frLportFragControl is
set to off, this value should be zero."
REFERENCE "FRF.12 [21]"
DEFVAL { 0 }
::= { frLportEntry 12 }
--
-- Frame Relay Management VC Signaling
--
frMgtVCSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrMgtVCSigEntry
Rehbehn & Fowler Standards Track [Page 22]
RFC 2954 Frame Relay Service MIB October 2000
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Management VC Signaling
Parameters and Errors table."
::= { frnetservObjects 2 }
frMgtVCSigEntry OBJECT-TYPE
SYNTAX FrMgtVCSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay Management VC
Signaling Parameters Errors table."
INDEX { ifIndex }
::= { frMgtVCSigTable 1 }
FrMgtVCSigEntry ::=
SEQUENCE {
frMgtVCSigProced INTEGER,
frMgtVCSigUserN391 INTEGER,
frMgtVCSigUserN392 INTEGER,
frMgtVCSigUserN393 INTEGER,
frMgtVCSigUserT391 INTEGER,
frMgtVCSigNetN392 INTEGER,
frMgtVCSigNetN393 INTEGER,
frMgtVCSigNetT392 INTEGER,
frMgtVCSigNetnN4 INTEGER,
frMgtVCSigNetnT3 INTEGER,
frMgtVCSigUserLinkRelErrors Counter32,
frMgtVCSigUserProtErrors Counter32,
frMgtVCSigUserChanInactive Counter32,
frMgtVCSigNetLinkRelErrors Counter32,
frMgtVCSigNetProtErrors Counter32,
frMgtVCSigNetChanInactive Counter32,
frMgtVCSigProcedAdmin INTEGER,
frMgtVCSigUserN391Admin INTEGER,
frMgtVCSigUserN392Admin INTEGER,
frMgtVCSigUserN393Admin INTEGER,
frMgtVCSigUserT391Admin INTEGER,
frMgtVCSigNetN392Admin INTEGER,
frMgtVCSigNetN393Admin INTEGER,
frMgtVCSigNetT392Admin INTEGER,
frMgtVCSigNetnT3Admin INTEGER
}
frMgtVCSigProced OBJECT-TYPE
SYNTAX INTEGER {
Rehbehn & Fowler Standards Track [Page 23]
RFC 2954 Frame Relay Service MIB October 2000
u2nnet(1),
bidirect(2),
u2nuser(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the local
in-channel signaling procedural role that is used
for this UNI/NNI logical port. Bidirectional
procedures implies that both user-side and
network-side procedural roles are used.
u2nnet(1) Logical port operates user to network
procedure in the role of the network
side
bidirect(2) Logical port operates the
bidirectional procedure (both user
and network side roles)
u2nuser(3) Logical port operates user to network
procedure in the role of the user
side"
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
::= { frMgtVCSigEntry 1 }
frMgtVCSigUserN391 OBJECT-TYPE
SYNTAX INTEGER (1..255)
UNITS "Polls"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the User-side
N391 full status polling cycle value for this
UNI/NNI logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not instantiated and an
attempt to read will result in the noSuchInstance
exception response."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
DEFVAL { 6 }
::= { frMgtVCSigEntry 2 }
frMgtVCSigUserN392 OBJECT-TYPE
SYNTAX INTEGER (1..10)
Rehbehn & Fowler Standards Track [Page 24]
RFC 2954 Frame Relay Service MIB October 2000
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the User-side
N392 error threshold value for this UNI/NNI
logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
DEFVAL { 3 }
::= { frMgtVCSigEntry 3 }
frMgtVCSigUserN393 OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the User-side
N393 monitored events count value for this UNI/NNI
logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
DEFVAL { 4 }
::= { frMgtVCSigEntry 4 }
frMgtVCSigUserT391 OBJECT-TYPE
SYNTAX INTEGER (5..30)
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the User-side
T391 link integrity verification polling timer
value for this UNI/NNI logical port. If the
logical port is not performing user-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
DEFVAL { 10 }
::= { frMgtVCSigEntry 5 }
frMgtVCSigNetN392 OBJECT-TYPE
SYNTAX INTEGER (1..10)
Rehbehn & Fowler Standards Track [Page 25]
RFC 2954 Frame Relay Service MIB October 2000
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Network-
side N392 error threshold value (nN2 for LMI) for
this UNI/NNI logical port. If the logical port is
not performing network-side procedures, then this
object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
DEFVAL { 3 }
::= { frMgtVCSigEntry 6 }
frMgtVCSigNetN393 OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Network-
side N393 monitored events count value (nN3 for
LMI) for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
DEFVAL { 4 }
::= { frMgtVCSigEntry 7 }
frMgtVCSigNetT392 OBJECT-TYPE
SYNTAX INTEGER (5..30)
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Network-
side T392 polling verification timer value (nT2
for LMI) for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
DEFVAL { 15 }
::= { frMgtVCSigEntry 8 }
Rehbehn & Fowler Standards Track [Page 26]
RFC 2954 Frame Relay Service MIB October 2000
frMgtVCSigNetnN4 OBJECT-TYPE
SYNTAX INTEGER (5..5)
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Network-
side nN4 maximum status enquires received value
for this UNI/NNI logical port. If the logical
port is not performing network-side procedures or
is not performing LMI procedures, then this object
is not instantiated.
This object applies only to LMI and always has a
value of 5."
REFERENCE "LMI [24]"
::= { frMgtVCSigEntry 9 }
frMgtVCSigNetnT3 OBJECT-TYPE
SYNTAX INTEGER (5 | 10 | 15 | 20 | 25 | 30)
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Network-
side nT3 timer (for nN4 status enquires received)
value for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures or is not performing LMI procedures,
then this object is not instantiated.
This object applies only to LMI."
REFERENCE "LMI [24]"
DEFVAL { 20 }
::= { frMgtVCSigEntry 10 }
frMgtVCSigUserLinkRelErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Errors"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of user-side local in-channel
signaling link reliability errors (i.e., non-
receipt of Status/Status Enquiry messages or
invalid sequence numbers in a Link Integrity
Verification Information Element) for this UNI/NNI
logical port. If the logical port is not
Rehbehn & Fowler Standards Track [Page 27]
RFC 2954 Frame Relay Service MIB October 2000
performing user-side procedures, then this object
is not instantiated."
::= { frMgtVCSigEntry 11 }
frMgtVCSigUserProtErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Errors"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of user-side local in-channel
signaling protocol errors (i.e., protocol
discriminator, unnumbered information, message
type, call reference, and mandatory information
element errors) for this UNI/NNI logical port. If
the logical port is not performing user-side
procedures, then this object is not instantiated."
::= { frMgtVCSigEntry 12 }
frMgtVCSigUserChanInactive OBJECT-TYPE
SYNTAX Counter32
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the user-side channel was
declared inactive (i.e., N392 errors in N393
events) for this UNI/NNI logical port. If the
logical port is not performing user-side
procedures, then this object is not instantiated."
::= { frMgtVCSigEntry 13 }
frMgtVCSigNetLinkRelErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Errors"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of network-side local in-channel
signaling link reliability errors (i.e., non-
receipt of Status/Status Enquiry messages or
invalid sequence numbers in a Link Integrity
Verification Information Element) for this UNI/NNI
logical port."
::= { frMgtVCSigEntry 14 }
frMgtVCSigNetProtErrors OBJECT-TYPE
SYNTAX Counter32
Rehbehn & Fowler Standards Track [Page 28]
RFC 2954 Frame Relay Service MIB October 2000
UNITS "Errors"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of network-side local in-channel
signaling protocol errors (i.e., protocol
discriminator, message type, call reference, and
mandatory information element errors) for this
UNI/NNI logical port."
::= { frMgtVCSigEntry 15 }
frMgtVCSigNetChanInactive OBJECT-TYPE
SYNTAX Counter32
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the network-side channel was
declared inactive (i.e., N392 errors in N393
events) for this UNI/NNI logical port."
::= { frMgtVCSigEntry 16 }
frMgtVCSigProcedAdmin OBJECT-TYPE
SYNTAX INTEGER {
u2nnet(1),
bidirect(2),
u2nuser(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the local
in-channel signaling procedural role that is used
for this UNI/NNI logical port. Bidirectional
procedures implies that both user-side and
network-side procedural roles are used.
u2nnet(1) Logical port operates user to network
procedure in the role of the network
side
bidirect(2) Logical port operates the
bidirectional procedure (both user
and network side roles)
u2nuser(3) Logical port operates user to network
procedure in the role of the user
side"
Rehbehn & Fowler Standards Track [Page 29]
RFC 2954 Frame Relay Service MIB October 2000
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
DEFVAL { u2nnet }
::= { frMgtVCSigEntry 17 }
frMgtVCSigUserN391Admin OBJECT-TYPE
SYNTAX INTEGER (1..255)
UNITS "Polls"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
User-side N391 full status polling cycle value for
this UNI/NNI logical port. If the logical port is
not performing user-side (bidirectional)
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
::= { frMgtVCSigEntry 18 }
frMgtVCSigUserN392Admin OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
User-side N392 error threshold value for this
UNI/NNI logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
::= { frMgtVCSigEntry 19 }
frMgtVCSigUserN393Admin OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
User-side N393 monitored events count value for
this UNI/NNI logical port. If the logical port is
not performing user-side (bidirectional)
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
Rehbehn & Fowler Standards Track [Page 30]
RFC 2954 Frame Relay Service MIB October 2000
::= { frMgtVCSigEntry 20 }
frMgtVCSigUserT391Admin OBJECT-TYPE
SYNTAX INTEGER (5..30)
UNITS "Seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
User-side T391 link integrity verification polling
timer value for this UNI/NNI logical port. If the
logical port is not performing user-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
::= { frMgtVCSigEntry 21 }
frMgtVCSigNetN392Admin OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
Network-side N392 error threshold value (nN2 for
LMI) for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
::= { frMgtVCSigEntry 22 }
frMgtVCSigNetN393Admin OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
Network-side N393 monitored events count value
(nN3 for LMI) for this UNI/NNI logical port. If
the logical port is not performing network-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
::= { frMgtVCSigEntry 23 }
Rehbehn & Fowler Standards Track [Page 31]
RFC 2954 Frame Relay Service MIB October 2000
frMgtVCSigNetT392Admin OBJECT-TYPE
SYNTAX INTEGER (5..30)
UNITS "Seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
Network-side T392 polling verification timer value
(nT2 for LMI) for this UNI/NNI logical port. If
the logical port is not performing network-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
::= { frMgtVCSigEntry 24 }
frMgtVCSigNetnT3Admin OBJECT-TYPE
SYNTAX INTEGER (5 | 10 | 15 | 20 | 25 | 30)
UNITS "Seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
Network-side nT3 timer (for nN4 status enquires
received) value for this UNI/NNI logical port. If
the logical port is not performing network-side
procedures or is not performing LMI procedures,
then this object is not instantiated. This object
applies only to LMI."
REFERENCE "LMI [24]"
::= { frMgtVCSigEntry 25 }
--
-- Frame Relay PVC End-points
--
frPVCEndptTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrPVCEndptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay PVC End-Point table. This table
is used to model a PVC end-point. This table
contains the traffic parameters and statistics for
a PVC end-point.
This table is used to identify the traffic
parameters for a bi-directional PVC segment end-
Rehbehn & Fowler Standards Track [Page 32]
RFC 2954 Frame Relay Service MIB October 2000
point, and it also provides statistics for a PVC
segment end-point.
A PVC segment end-point is identified by a UNI/NNI
logical port index value and DLCI index value.
If the frame relay service provider allows the
frame relay CNM subscriber to create, modify or
delete PVCs using SNMP, then this table is used to
identify and reserve the requested traffic
parameters of each PVC segment end-point. The
Connection table is used to 'connect' the end-
points together. Not all implementations will
support the capability of
creating/modifying/deleting PVCs using SNMP as a
feature of frame relay CNM service.
Uni-directional PVCs are modeled with zero valued
traffic parameters in one of the directions (In or
Out direction) in this table.
To create a PVC, the following procedures shall be
followed:
1) Create the entries for the PVC segment
endpoints in the frPVCEndptTable by specifying
the traffic parameters for the bi-directional
PVC segment endpoints. As shown in figure 2, a
point-to-point PVC has two endpoints, thus two
entries in this table. Uni-directional PVCs
are modeled with zero valued traffic
parameters in one direction; all the `In'
direction parameters for one frame relay PVC
End-point or all the `Out' direction
parameters for the other frame relay PVC
Endpoint.
In _____________________________ Out
>>>>>>| |>>>>>>>>
______| Frame Relay Network |________
Out | | In
<<<<<<|_____________________________|<<<<<<<<
Frame Relay Frame Relay
PVC PVC
Endpoint Endpoint
Figure 2, PVC Terminology
Rehbehn & Fowler Standards Track [Page 33]
RFC 2954 Frame Relay Service MIB October 2000
2) Go to the Frame Relay Connection Group."
::= { frnetservObjects 3 }
frPVCEndptEntry OBJECT-TYPE
SYNTAX FrPVCEndptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay PVC Endpoint table."
INDEX { ifIndex, frPVCEndptDLCIIndex }
::= { frPVCEndptTable 1 }
FrPVCEndptEntry ::=
SEQUENCE {
frPVCEndptDLCIIndex Integer32,
frPVCEndptInMaxFrameSize Integer32,
frPVCEndptInBc Integer32,
frPVCEndptInBe Integer32,
frPVCEndptInCIR Integer32,
frPVCEndptOutMaxFrameSize Integer32,
frPVCEndptOutBc Integer32,
frPVCEndptOutBe Integer32,
frPVCEndptOutCIR Integer32,
frPVCEndptConnectIdentifier Integer32,
frPVCEndptRowStatus RowStatus,
frPVCEndptRcvdSigStatus INTEGER,
frPVCEndptInFrames Counter32,
frPVCEndptOutFrames Counter32,
frPVCEndptInDEFrames Counter32,
frPVCEndptInExcessFrames Counter32,
frPVCEndptOutExcessFrames Counter32,
frPVCEndptInDiscards Counter32,
frPVCEndptInOctets Counter32,
frPVCEndptOutOctets Counter32,
frPVCEndptInDiscardsDESet Counter32,
frPVCEndptInFramesFECNSet Counter32,
frPVCEndptOutFramesFECNSet Counter32,
frPVCEndptInFramesBECNSet Counter32,
frPVCEndptOutFramesBECNSet Counter32,
frPVCEndptInCongDiscards Counter32,
frPVCEndptInDECongDiscards Counter32,
frPVCEndptOutCongDiscards Counter32,
frPVCEndptOutDECongDiscards Counter32,
frPVCEndptOutDEFrames Counter32,
frPVCEndptAtmIwfConnIndex Integer32
}
Rehbehn & Fowler Standards Track [Page 34]
RFC 2954 Frame Relay Service MIB October 2000
frPVCEndptDLCIIndex OBJECT-TYPE
SYNTAX Integer32 (16..4194303)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the DLCI
value for this PVC end-point.
The values are restricted to the legal range for
the size of address field supported by the logical
port (frLportAddrDLCILen)."
REFERENCE "Q.922 [25]"
::= { frPVCEndptEntry 1 }
frPVCEndptInMaxFrameSize OBJECT-TYPE
SYNTAX Integer32 (1..4096)
UNITS "Octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is the size in octets of
the largest frame relay information field for this
PVC end-point in the ingress direction (into the
frame relay network). The value of
frPVCEndptInMaxFrameSize must be less than or
equal to the corresponding ifMtu for this frame
relay UNI/NNI logical port."
REFERENCE "FRF.1 [31]
Q.922 [25]
Q.933 [22]"
DEFVAL { 1600 }
::= { frPVCEndptEntry 2 }
frPVCEndptInBc OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the
committed burst size (Bc) parameter (measured in
bits) for this PVC end-point in the ingress
direction (into the frame relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (16383 *
10**6).
Rehbehn & Fowler Standards Track [Page 35]
RFC 2954 Frame Relay Service MIB October 2000
Note that the value is encoded in bits whilst the
Q.933 Link layer core parameters information
element encodes this information using octet
units."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 3 }
frPVCEndptInBe OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the excess
burst size (Be) parameter (measured in bits) for
this PVC end-point in the ingress direction (into
the frame relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (16383 *
10**6).
Note that the value is encoded in bits whilst the
Q.933 Link layer core parameters information
element encodes this information using octet
units."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 4 }
frPVCEndptInCIR OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits per Second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the
committed information rate (CIR) parameter
(measured in bits per second) for this PVC end-
point in the ingress direction (into the frame
relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (2047 *
10**6)."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 5 }
frPVCEndptOutMaxFrameSize OBJECT-TYPE
Rehbehn & Fowler Standards Track [Page 36]
RFC 2954 Frame Relay Service MIB October 2000
SYNTAX Integer32 (1..4096)
UNITS "Octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is the size in octets of
the largest frame relay information field for this
PVC end-point in the egress direction (out of the
frame relay network). The value of
frPVCEndptOutMaxFrameSize must be less than or
equal to the corresponding ifMtu for this frame
relay UNI/NNI logical port."
REFERENCE "FRF.1 [31]
Q.922 [25]
Q.933 [22]"
DEFVAL { 1600 }
::= { frPVCEndptEntry 6 }
frPVCEndptOutBc OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the
committed burst size (Bc) parameter (measured in
bits) for this PVC end-point in the egress
direction (out of the frame relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (16383 *
10**6).
Note that the value is encoded in bits whilst the
Q.933 Link layer core parameters information
element encodes this information using octet
units."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 7 }
frPVCEndptOutBe OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the excess
burst size (Be) parameter (measured in bits) for
Rehbehn & Fowler Standards Track [Page 37]
RFC 2954 Frame Relay Service MIB October 2000
this PVC end-point in the egress direction (out of
the frame relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (16383 *
10**6).
Note that the value is encoded in bits whilst the
Q.933 Link layer core parameters information
element encodes this information using octet
units."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 8 }
frPVCEndptOutCIR OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits per Second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the
committed information rate (CIR) parameter
(measured in bits per second) for this PVC end-
point in the egress direction (out of the frame
relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (2047 *
10**6)."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 9 }
frPVCEndptConnectIdentifier OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to associate PVC end-points
as being part of one PVC segment connection. This
value of this object is equal to the value of
frPVCConnectIndex, which is used as one of the
indices into the frPVCConnectTable.
A connection that has been cross-connected via the
FR/ATM PVC Service IWF cross-connect table will
return the value zero when this object is read. In
case of these interworked connections, the
frPVCEndptAtmIwfConnIndex object must be accessed
Rehbehn & Fowler Standards Track [Page 38]
RFC 2954 Frame Relay Service MIB October 2000
to select the entry in the FR/ATM PVC Service IWF
cross-connect table.
The value of this object is provided by the agent,
after the associated entries in the
frPVCConnectTable or frAtmIwfConnectionTable have
been created."
::= { frPVCEndptEntry 10 }
frPVCEndptRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create new rows in this
table, modify existing rows, and to delete
existing rows. To create a new PVC, the entries
for the PVC segment end-points in the
frPVCEndptTable must first be created. Next, the
frPVCConnectTable is used to associate the frame
relay PVC segment end-points. In order for the
manager to have the necessary error diagnostics,
the frPVCEndptRowStatus object must initially be
set to `createAndWait(5)'. While the
frPVCEndptRowStatus object is in the
`createAndWait(5)' state, the manager can set each
columnar object and get the necessary error
diagnostics. The frPVCEndptRowStatus object may
not be set to `active(1)' unless the following
columnar objects exist in this row:
frPVCEndptInMaxFrameSize, frPVCEndptInBc,
frPVCEndptInBe, frPVCEndptInCIR,
frPVCEndptOutMaxFrameSize, frPVCEndptOutBc,
frPVCEndptOutBe, and frPVCEndptOutCIR."
::= { frPVCEndptEntry 11 }
frPVCEndptRcvdSigStatus OBJECT-TYPE
SYNTAX INTEGER {
deleted(1),
active(2),
inactive(3),
none(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the PVC
status received via the local in-channel signaling
Rehbehn & Fowler Standards Track [Page 39]
RFC 2954 Frame Relay Service MIB October 2000
procedures for this PVC end-point. This object is
only pertinent for interfaces that perform the
bidirectional procedures.
Each value has the following meaning:
deleted(1): This PVC is not listed in the full
status reports received from the
user device. The object retains
this value for as long as the PVC
is not listed in the full status
reports
active(2): This PVC is reported as active, or
operational, by the user device.
inactive(3): This PVC is reported as inactive,
or non-operational, by the user
device.
none(4): This interface is only using the
network-side in-channel signaling
procedures, so this object does
not apply."
::= { frPVCEndptEntry 12 }
frPVCEndptInFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) for this PVC end-point. This includes
any frames discarded by the network due to
submitting more than Bc + Be data or due to any
network congestion recovery procedures."
::= { frPVCEndptEntry 13 }
frPVCEndptOutFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent by the network (egress)
regardless of whether they are Bc or Be frames for
this PVC end-point."
::= { frPVCEndptEntry 14 }
Rehbehn & Fowler Standards Track [Page 40]
RFC 2954 Frame Relay Service MIB October 2000
frPVCEndptInDEFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) with the DE bit set to (1) for this PVC
end-point."
::= { frPVCEndptEntry 15 }
frPVCEndptInExcessFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) for this PVC end-point which were
treated as excess traffic. Frames which are sent
to the network with DE set to zero are treated as
excess when more than Bc bits are submitted to the
network during the Committed Information Rate
Measurement Interval (Tc). Excess traffic may or
may not be discarded at the ingress if more than
Bc + Be bits are submitted to the network during
Tc. Traffic discarded at the ingress is not
recorded in frPVCEndptInExcessFrames. Frames
which are sent to the network with DE set to one
are also treated as excess traffic."
::= { frPVCEndptEntry 16 }
frPVCEndptOutExcessFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent by the network (egress)
for this PVC end-point which were treated as
excess traffic. (The DE bit may be set to one.)"
::= { frPVCEndptEntry 17 }
frPVCEndptInDiscards OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
Rehbehn & Fowler Standards Track [Page 41]
RFC 2954 Frame Relay Service MIB October 2000
DESCRIPTION
"The number of frames received by the network
(ingress) that were discarded due to traffic
enforcement for this PVC end-point. Congestion
discards are not counted in this object."
::= { frPVCEndptEntry 18 }
frPVCEndptInOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets received by the network
(ingress) for this PVC end-point. This counter
should only count octets from the beginning of the
frame relay header field to the end of user data.
If the network supporting frame relay can not
count octets, then this count should be an
approximation."
::= { frPVCEndptEntry 19 }
frPVCEndptOutOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets sent by the network (egress)
for this PVC end-point. This counter should only
count octets from the beginning of the frame relay
header field to the end of user data. If the
network supporting frame relay can not count
octets, then this count should be an
approximation."
::= { frPVCEndptEntry 20 }
frPVCEndptInDiscardsDESet OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) that were discarded with the DE bit set
due to traffic enforcement for this PVC end-point.
Congestion discards are not counted in this
object."
Rehbehn & Fowler Standards Track [Page 42]
RFC 2954 Frame Relay Service MIB October 2000
::= { frPVCEndptEntry 21 }
frPVCEndptInFramesFECNSet OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) that have the FECN bit set for this PVC
end-point."
::= { frPVCEndptEntry 22 }
frPVCEndptOutFramesFECNSet OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent by the network (egress)
that have the FECN bit set for this PVC end-
point."
::= { frPVCEndptEntry 23 }
frPVCEndptInFramesBECNSet OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) that have the BECN bit set for this PVC
end-point."
::= { frPVCEndptEntry 24 }
frPVCEndptOutFramesBECNSet OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent by the network (egress)
that have the BECN bit set for this PVC end-
point."
::= { frPVCEndptEntry 25 }
frPVCEndptInCongDiscards OBJECT-TYPE
SYNTAX Counter32
Rehbehn & Fowler Standards Track [Page 43]
RFC 2954 Frame Relay Service MIB October 2000
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) that were discarded due to input buffer
congestion, rather than traffic enforcement, for
this PVC end-point."
::= { frPVCEndptEntry 26 }
frPVCEndptInDECongDiscards OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames counted by
frPVCEndptInCongDiscards with the DE bit set to
(1)."
::= { frPVCEndptEntry 27 }
frPVCEndptOutCongDiscards OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent by the network (egress)
that were discarded due to output buffer
congestion for this PVC end-point."
::= { frPVCEndptEntry 28 }
frPVCEndptOutDECongDiscards OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames counted by
frPVCEndptOutCongDiscards with the DE bit set to
(1)."
::= { frPVCEndptEntry 29 }
frPVCEndptOutDEFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
Rehbehn & Fowler Standards Track [Page 44]
RFC 2954 Frame Relay Service MIB October 2000
DESCRIPTION
"The number of frames sent by the network (egress)
with the DE bit set to (1) for this PVC end-
point."
::= { frPVCEndptEntry 30 }
frPVCEndptAtmIwfConnIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the index value of the
FR/ATM cross-connect table entry used to link the
frame relay PVC with an ATM PVC.
Each row of the frPVCEndptTable that is not
cross-connected with an ATM PVC must return the
value zero when this object is read.
The value of this object is initialized by the
agent after the associated entries in the
frAtmIwfConnectionTable have been created.
The value of this object is reset to zero
following destruction of the associated entry in
the frAtmIwfConnectionTable"
::= { frPVCEndptEntry 31 }
--
-- Frame Relay PVC Connections
--
frPVCConnectIndexValue OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns a hint to be used for
frPVCConnectIndex when creating entries in the
frPVCConnectTable.
The value 0 indicates that no unassigned entries
are available.
To obtain the frPVCConnectIndex value for a new
entry, the manager issues a management protocol
retrieval operation to obtain the current value of
this object. After each retrieval, the agent must
Rehbehn & Fowler Standards Track [Page 45]
RFC 2954 Frame Relay Service MIB October 2000
modify the value to the next unassigned index to
prevent assignment of the same value to multiple
management systems.
A management system should repeat the read to
obtain a new value should an attempt to create the
new row using the previously returned hint fail."
::= { frnetservObjects 4 }
frPVCConnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrPVCConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay PVC Connect Table is used to
model the bi-directional PVC segment flows
including: point-to-point PVCs, point-to-
multipoint PVCs, and multipoint-to-multipoint
PVCs.
This table has read-create access and is used to
associate PVC end-points together as belonging to
one connection. The frPVCConnectIndex is used to
associate all the bi-directional flows. Not all
implementations will support the capability of
creating/modifying/deleting PVCs using SNMP as a
feature of frame relay CNM service.
Once the entries in the frPVCEndptTable are
created, the following step are used to associate
the PVC end-points as belonging to one PVC
connection:
1) Obtain a unique frPVCConnectIndex
using the frPVCConnectIndexValue object.
2) Connect the PVC segment endpoints together
with the applicable frPVCConnectIndex value
obtained via frPVCConnectIndexValue. The
entries in this table are created by using
the frPVCConnectRowStatus object.
3) The agent will provide the value of the
corresponding instances of
frPVCEndptConnectIdentifier with the
frPVCConnectIndex value.
4) Set frPVCConnectAdminStatus to `active(1)' in
Rehbehn & Fowler Standards Track [Page 46]
RFC 2954 Frame Relay Service MIB October 2000
all rows for this PVC segment to turn the
PVC on.
For example, the Frame Relay PVC Connection Group
models a bi-directional, point-to-point PVC
segment as one entry in this table.
Frame Relay Frame Relay
Network Network
Low Port High Port
__________________________________
| |
_____| >> from low to high PVC flow >> |_____
| << from high to low PVC flow << |
|__________________________________|
The terms low and high are chosen to represent
numerical ordering of a PVC segment's endpoints
for representation in this table. That is, the
endpoint with the lower value of ifIndex is termed
'low', while the opposite endpoint of the segment
is termed 'high'. This terminology is to provide
directional information; for example the
frPVCConnectL2hOperStatus and
frPVCConnectH2lOperStatus as illustrated above.
If the Frame Relay Connection table is used to
model a unidirectional PVC, then one direction
(either from low to high or from high to low) has
its Operational Status equal to down.
A PVC segment is a portion of a PVC that traverses
one Frame Relay Network, and a PVC segment is
identified by its two end-points (UNI/NNI logical
port index value and DLCI index value) through one
Frame Relay Network."
::= { frnetservObjects 5 }
frPVCConnectEntry OBJECT-TYPE
SYNTAX FrPVCConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay PVC Connect table.
This entry is used to model a PVC segment in two
directions."
INDEX { frPVCConnectIndex,
frPVCConnectLowIfIndex,
Rehbehn & Fowler Standards Track [Page 47]
RFC 2954 Frame Relay Service MIB October 2000
frPVCConnectLowDLCIIndex,
frPVCConnectHighIfIndex,
frPVCConnectHighDLCIIndex }
::= { frPVCConnectTable 1 }
FrPVCConnectEntry ::=
SEQUENCE {
frPVCConnectIndex Integer32,
frPVCConnectLowIfIndex InterfaceIndex,
frPVCConnectLowDLCIIndex Integer32,
frPVCConnectHighIfIndex InterfaceIndex,
frPVCConnectHighDLCIIndex Integer32,
frPVCConnectAdminStatus INTEGER,
frPVCConnectL2hOperStatus INTEGER,
frPVCConnectH2lOperStatus INTEGER,
frPVCConnectL2hLastChange TimeStamp,
frPVCConnectH2lLastChange TimeStamp,
frPVCConnectRowStatus RowStatus,
frPVCConnectUserName SnmpAdminString,
frPVCConnectProviderName SnmpAdminString
}
frPVCConnectIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the
frPVCConnectIndexValue obtained to uniquely
identify this PVC segment connection."
::= { frPVCConnectEntry 1 }
frPVCConnectLowIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to IF-MIB
ifIndex value of the UNI/NNI logical port for this
PVC segment. The term low implies that this PVC
segment end-point has the numerically lower
ifIndex value than the connected/associated PVC
segment end-point.
RFC 1604 permitted a zero value for this object to
identify termination at a non-frame relay
interface. However, this cross-connect table is
limited to frame relay connections. See the frame
Rehbehn & Fowler Standards Track [Page 48]
RFC 2954 Frame Relay Service MIB October 2000
relay/ATM IWF MIB [28] for the cross-connect table
used for those types of connections."
::= { frPVCConnectEntry 2 }
frPVCConnectLowDLCIIndex OBJECT-TYPE
SYNTAX Integer32 (16..4194303)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the DLCI
value for this end-point of the PVC segment."
REFERENCE "Q.922 [25]"
::= { frPVCConnectEntry 3 }
frPVCConnectHighIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to IF-MIB
ifIndex value for the UNI/NNI logical port for
this PVC segment. The term high implies that this
PVC segment end-point has the numerically higher
ifIndex value than the connected/associated PVC
segment end-point."
::= { frPVCConnectEntry 4 }
frPVCConnectHighDLCIIndex OBJECT-TYPE
SYNTAX Integer32 (16..4194303)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the egress
DLCI value for this end-point of the PVC segment."
REFERENCE "Q.922 [25]"
::= { frPVCConnectEntry 5 }
frPVCConnectAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2),
testing(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the desired
administrative status of this bi-directional PVC
Rehbehn & Fowler Standards Track [Page 49]
RFC 2954 Frame Relay Service MIB October 2000
segment. The active(1) state means the PVC
segment is currently operational; the inactive(2)
state means the PVC segment is currently not
operational; the testing(3) state means the PVC
segment is currently undergoing a test. This
state is set by an administrative entity. This
value affects the PVC status indicated across the
ingress NNI/UNI of both end-points of the bi-
directional PVC segment. When a PVC segment
connection is created using this table, this
object is initially set to `inactive(2)'. After
the frPVCConnectRowStatus object is set to
`active(1)' (and the corresponding/associated
entries in the frPVCEndptTable have their
frPVCEndptRowStatus object set to `active(1)'),
the frPVCConnectAdminStatus object may be set to
`active(1)' to turn on the PVC segment
connection."
::= { frPVCConnectEntry 6 }
frPVCConnectL2hOperStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2),
testing(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the current
operational status of the PVC segment connection
in one direction; (i.e., in the low to high
direction). This value affects the PVC status
indicated across the ingress NNI/UNI (low side) of
the PVC segment.
The values mean:
active(1) - PVC is currently operational
inactive(2) - PVC is currently not operational.
This may be because of an underlying
LMI or DS1 failure.
testing(3) - PVC is currently undergoing a test.
This may be because of an underlying
frLport or DS1 undergoing a test.
Rehbehn & Fowler Standards Track [Page 50]
RFC 2954 Frame Relay Service MIB October 2000
unknown(4) - the status of the PVC currently can
not be determined."
::= { frPVCConnectEntry 7 }
frPVCConnectH2lOperStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2),
testing(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the current
operational status of the PVC segment connection
in one direction; (i.e., in the high to low
direction).. This value affects the PVC status
indicated across the ingress NNI/UNI (high side)
of the PVC segment.
The values mean:
active(1) - PVC is currently operational
inactive(2) - PVC is currently not operational.
This may be because of an underlying
LMI or DS1 failure.
testing(3) - PVC is currently undergoing a test.
This may be because of an underlying
frLport or DS1 undergoing a test.
unknown(4) - the status of the PVC currently can
not be determined."
::= { frPVCConnectEntry 8 }
frPVCConnectL2hLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the Interface MIB's sysUpTime object
at the time this PVC segment entered its current
operational state in the low to high direction.
If the current state was entered prior to the last
re-initialization of the FRS agent, then this
object contains a zero value."
Rehbehn & Fowler Standards Track [Page 51]
RFC 2954 Frame Relay Service MIB October 2000
::= { frPVCConnectEntry 9 }
frPVCConnectH2lLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the Interface MIB's sysUpTime object
at the time this PVC segment entered its current
operational state in the high to low direction.
If the current state was entered prior to the last
re-initialization of the FRS agent, then this
object contains a zero value."
::= { frPVCConnectEntry 10 }
frPVCConnectRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this entry in the
frPVCConnectTable. This variable is used to
create new connections for the PVC end-points and
to change existing connections of the PVC end-
points. This object must be initially set to
`createAndWait(5)'. In this state, the agent
checks the parameters in the associated entries in
the frPVCEndptTable to verify that the PVC end-
points can be connected (i.e., the In parameters
for one PVC end-point are equal to the Out
parameters for the other PVC end-point). This
object can not be set to `active(1)' unless the
following columnar object exists in this row:
frPVCConnectAdminStatus. The agent also supplies
the associated value of frPVCConnectIndex for the
frPVCEndptConnectIdentifier instances. To turn on
a PVC segment connection, the
frPVCConnectAdminStatus is set to `active(1)'."
::= { frPVCConnectEntry 11 }
frPVCConnectUserName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is a service user assigned textual
representation of a PVC."
::= { frPVCConnectEntry 12 }
Rehbehn & Fowler Standards Track [Page 52]
RFC 2954 Frame Relay Service MIB October 2000
frPVCConnectProviderName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is a system supplied textual representation
of PVC. It is assigned by the service provider."
::= { frPVCConnectEntry 13 }
--
-- The Frame Relay Accounting
--
frAccountPVCTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrAccountPVCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Accounting PVC table. This table
is used to perform accounting on a PVC segment
end-point basis."
::= { frnetservObjects 6 }
frAccountPVCEntry OBJECT-TYPE
SYNTAX FrAccountPVCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay Accounting PVC
table."
INDEX { ifIndex,
frAccountPVCDLCIIndex }
::= { frAccountPVCTable 1 }
FrAccountPVCEntry ::=
SEQUENCE {
frAccountPVCDLCIIndex Integer32,
frAccountPVCSegmentSize Integer32,
frAccountPVCInSegments Counter32,
frAccountPVCOutSegments Counter32
}
frAccountPVCDLCIIndex OBJECT-TYPE
SYNTAX Integer32 (16..4194303)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the DLCI
Rehbehn & Fowler Standards Track [Page 53]
RFC 2954 Frame Relay Service MIB October 2000
value for this PVC segment end-point."
REFERENCE "Q.922 [25]"
::= { frAccountPVCEntry 1 }
frAccountPVCSegmentSize OBJECT-TYPE
SYNTAX Integer32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the Segment
Size for this PVC segment end-point."
::= { frAccountPVCEntry 2 }
frAccountPVCInSegments OBJECT-TYPE
SYNTAX Counter32
UNITS "Segments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the number
of segments received by this PVC segment end-
point."
::= { frAccountPVCEntry 3 }
frAccountPVCOutSegments OBJECT-TYPE
SYNTAX Counter32
UNITS "Segments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the number
of segments sent by this PVC segment end-point."
::= { frAccountPVCEntry 4 }
--
-- Accounting on a Frame Relay Logical Port
--
frAccountLportTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrAccountLportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Accounting Logical Port table.
This table is used to perform accounting on a
UNI/NNI Logical Port basis."
::= { frnetservObjects 7 }
Rehbehn & Fowler Standards Track [Page 54]
RFC 2954 Frame Relay Service MIB October 2000
frAccountLportEntry OBJECT-TYPE
SYNTAX FrAccountLportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay Accounting Logical
Port table."
INDEX { ifIndex }
::= { frAccountLportTable 1 }
FrAccountLportEntry ::=
SEQUENCE {
frAccountLportSegmentSize
Integer32,
frAccountLportInSegments
Counter32,
frAccountLportOutSegments
Counter32
}
frAccountLportSegmentSize OBJECT-TYPE
SYNTAX Integer32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the Segment
Size for this UNI/NNI logical port."
::= { frAccountLportEntry 1 }
frAccountLportInSegments OBJECT-TYPE
SYNTAX Counter32
UNITS "Segments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the number
of segments received by this UNI/NNI logical
port."
::= { frAccountLportEntry 2 }
frAccountLportOutSegments OBJECT-TYPE
SYNTAX Counter32
UNITS "Segments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the number
Rehbehn & Fowler Standards Track [Page 55]
RFC 2954 Frame Relay Service MIB October 2000
of segments sent by this UNI/NNI logical port."
::= { frAccountLportEntry 3 }
--
-- Frame Relay Network Service Notifications
--
frPVCConnectStatusChange NOTIFICATION-TYPE
OBJECTS { frPVCConnectIndex,
frPVCConnectLowIfIndex,
frPVCConnectLowDLCIIndex,
frPVCConnectHighIfIndex,
frPVCConnectHighDLCIIndex,
frPVCConnectL2hOperStatus,
frPVCConnectH2lOperStatus,
frPVCEndptRcvdSigStatus }
STATUS deprecated
DESCRIPTION
"Refer to the description of the
frPVCConnectStatusNotif notification that has
replaced this notification. The notification is
deprecated due to the incorrect inclusion of index
values and to take advantage of the trap prefix
for automatic conversion from SMIv2 to SMIv1 by
making the one but last sub-ID a zero (i.e. the
so-called trap prefix)."
::= { frnetservTraps 1 }
frPVCConnectStatusNotif NOTIFICATION-TYPE
OBJECTS { frPVCConnectL2hOperStatus,
frPVCConnectH2lOperStatus,
frPVCEndptRcvdSigStatus }
STATUS current
DESCRIPTION
"This notification indicates that the indicated
PVC has changed state.
This notification is not sent if an FR-UNI changes
state; a linkDown or linkUp notification should be
sent instead. The first instance of
frPVCEndptRcvdSigStatus is for the endpoint with
LowIfIndex, LowDLCIIndex. The second instance of
frPVCEndptRcvdSigStatus is for the endpoint with
HighIfIndex, HighDLCIIndex"
::= { frnetservTrapsPrefix 2 }
-- Conformance Information
Rehbehn & Fowler Standards Track [Page 56]
RFC 2954 Frame Relay Service MIB October 2000
frnetservConformance OBJECT IDENTIFIER
::= { frnetservMIB 3 }
frnetservGroups OBJECT IDENTIFIER
::= { frnetservConformance 1 }
frnetservCompliances OBJECT IDENTIFIER
::= { frnetservConformance 2 }
--
-- Service (Read-only) Modules
--
frnetservCompliance2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which
have Frame Relay Network Service Interfaces.
The distinction between 'service' and 'switch' is
that a 'switch' is configured via this MIB.
Hence, the various read/write objects have write
capability. A 'service' represents a passive
monitor-only customer network management
interface. The various read/write objects are
restricted to read-only capability."
MODULE -- this module
MANDATORY-GROUPS { frnetservLportGroup2,
frnetservMgtVCSigGroup,
frnetservPVCEndptGroup,
frnetservPVCEndptGroup2,
frnetservPVCConnectGroup,
frnetservPVCConnectNamesGroup,
frnetservPVCNotifGroup2 }
GROUP frnetservAccountPVCGroup
DESCRIPTION
"This group is optional for frame relay
interfaces. It is mandatory if and only if
accounting is performed on a PVC basis this frame
relay interface."
GROUP frnetservAccountLportGroup
DESCRIPTION
"This group is optional for frame relay
interfaces. It is mandatory if and only if
accounting is performed on a logical port basis
this frame relay interface."
OBJECT frPVCEndptInMaxFrameSize
Rehbehn & Fowler Standards Track [Page 57]
RFC 2954 Frame Relay Service MIB October 2000
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInBc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInBe
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInCIR
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutMaxFrameSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutBc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutBe
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutCIR
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptRowStatus
-- subset of RowStatus
SYNTAX INTEGER { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the
six enumerated values for the RowStatus textual
convention need be supported, specifically:
active(1)."
Rehbehn & Fowler Standards Track [Page 58]
RFC 2954 Frame Relay Service MIB October 2000
OBJECT frPVCConnectAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCConnectRowStatus
-- subset of RowStatus
SYNTAX INTEGER { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the
six enumerated values for the RowStatus textual
convention need be supported, specifically:
active(1)."
OBJECT frLportFragControl
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frLportFragSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCConnectUserName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCConnectProviderName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { frnetservCompliances 2 }
--
-- Switch (Configuration) Compliance
--
frnetSwitchCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which
have Frame Relay Network Switch objects.
The distinction between 'service' and 'switch' is
that a 'switch' is configured via this MIB.
Rehbehn & Fowler Standards Track [Page 59]
RFC 2954 Frame Relay Service MIB October 2000
Hence, the various read/write objects have write
capability. A 'service' represents a passive
monitor-only customer network management
interface. The various read/write objects are
restricted to read-only capability."
MODULE -- this module
MANDATORY-GROUPS { frnetservLportGroup2,
frnetservLportAdminGroup,
frnetservMgtVCSigGroup,
frnetservMgtVCSigAdminGroup,
frnetservPVCEndptGroup,
frnetservPVCEndptGroup2,
frnetservPVCConnectGroup,
frnetservPVCConnectNamesGroup,
frnetservPVCNotifGroup2 }
GROUP frnetservAccountPVCGroup
DESCRIPTION
"This group is optional for frame relay
interfaces. It is mandatory if and only if
accounting is performed on a PVC basis this frame
relay interface."
GROUP frnetservAccountLportGroup
DESCRIPTION
"This group is optional for frame relay
interfaces. It is mandatory if and only if
accounting is performed on a logical port basis
this frame relay interface."
::= { frnetservCompliances 3 }
--
-- Historical RFC 1604 Compliance Modules
--
frnetservCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for SNMP entities which
have Frame Relay Network Service Interfaces.
This compliance statement has been deprecated in
favor of frnetservCompliance2. The new compliance
module expands the mandatory groups to include
notification and other new objects."
MODULE -- this module
MANDATORY-GROUPS { frnetservLportGroup,
Rehbehn & Fowler Standards Track [Page 60]
RFC 2954 Frame Relay Service MIB October 2000
frnetservMgtVCSigGroup,
frnetservPVCEndptGroup,
frnetservPVCConnectGroup }
GROUP frnetservAccountPVCGroup
DESCRIPTION
"This group is optional for Frame Relay
interfaces. It is mandatory if and only if
accounting is performed on a PVC basis this Frame
Relay interface."
GROUP frnetservAccountLportGroup
DESCRIPTION
"This group is optional for Frame Relay
interfaces. It is mandatory if and only if
accounting is performed on a logical port basis
this Frame Relay interface."
OBJECT frPVCEndptInMaxFrameSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInBc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInBe
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInCIR
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutMaxFrameSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutBc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutBe
Rehbehn & Fowler Standards Track [Page 61]
RFC 2954 Frame Relay Service MIB October 2000
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutCIR
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptRowStatus
-- subset of RowStatus
SYNTAX INTEGER { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the
six enumerated values for the RowStatus textual
convention need be supported, specifically:
active(1)."
OBJECT frPVCConnectAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCConnectRowStatus
-- subset of RowStatus
SYNTAX INTEGER { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the
six enumerated values for the RowStatus textual
convention need be supported, specifically:
active(1)."
::= { frnetservCompliances 1 }
--
-- Frame Relay Service MIB Object Groups
--
frnetservLportGroup OBJECT-GROUP
OBJECTS { frLportNumPlan, frLportContact, frLportLocation,
frLportType,
frLportAddrDLCILen, frLportVCSigProtocol,
frLportVCSigPointer }
STATUS deprecated
DESCRIPTION
"A collection of objects providing information
applicable to a Frame Relay Logical Port. This
group has been deprecated to eliminate reference
Rehbehn & Fowler Standards Track [Page 62]
RFC 2954 Frame Relay Service MIB October 2000
to the object frLportVCSigPointer.
Use the new group frnetservLportGroup2 as a
replacement for this group."
::= { frnetservGroups 1 }
frnetservMgtVCSigGroup OBJECT-GROUP
OBJECTS { frMgtVCSigProced,
frMgtVCSigUserN391,
frMgtVCSigUserN392,
frMgtVCSigUserN393,
frMgtVCSigUserT391,
frMgtVCSigNetN392,
frMgtVCSigNetN393,
frMgtVCSigNetT392,
frMgtVCSigNetnN4,
frMgtVCSigNetnT3,
frMgtVCSigUserLinkRelErrors,
frMgtVCSigUserProtErrors,
frMgtVCSigUserChanInactive,
frMgtVCSigNetLinkRelErrors,
frMgtVCSigNetProtErrors,
frMgtVCSigNetChanInactive }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to the Local In-Channel Signaling
Procedures used for a UNI/NNI logical port."
::= { frnetservGroups 2 }
frnetservPVCEndptGroup OBJECT-GROUP
OBJECTS { frPVCConnectIndexValue,
frPVCEndptInMaxFrameSize,
frPVCEndptInBc,
frPVCEndptInBe,
frPVCEndptInCIR,
frPVCEndptOutMaxFrameSize,
frPVCEndptOutBc,
frPVCEndptOutBe,
frPVCEndptOutCIR,
frPVCEndptConnectIdentifier,
frPVCEndptRowStatus,
frPVCEndptRcvdSigStatus,
frPVCEndptInFrames,
frPVCEndptOutFrames,
frPVCEndptInDEFrames,
frPVCEndptInExcessFrames,
frPVCEndptOutExcessFrames,
Rehbehn & Fowler Standards Track [Page 63]
RFC 2954 Frame Relay Service MIB October 2000
frPVCEndptInDiscards,
frPVCEndptInOctets,
frPVCEndptOutOctets }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to a Frame Relay PVC end-point."
::= { frnetservGroups 3 }
frnetservPVCConnectGroup OBJECT-GROUP
OBJECTS { frPVCConnectAdminStatus,
frPVCConnectL2hOperStatus,
frPVCConnectH2lOperStatus,
frPVCConnectL2hLastChange,
frPVCConnectH2lLastChange,
frPVCConnectRowStatus }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to a Frame Relay PVC connection."
::= { frnetservGroups 4 }
frnetservAccountPVCGroup OBJECT-GROUP
OBJECTS { frAccountPVCSegmentSize,
frAccountPVCInSegments,
frAccountPVCOutSegments }
STATUS current
DESCRIPTION
"A collection of objects providing accounting
information application to a Frame Relay PVC end-
point."
::= { frnetservGroups 5 }
frnetservAccountLportGroup OBJECT-GROUP
OBJECTS { frAccountLportSegmentSize,
frAccountLportInSegments,
frAccountLportOutSegments }
STATUS current
DESCRIPTION
"A collection of objects providing accounting
information application to a Frame Relay logical
port."
::= { frnetservGroups 6 }
frnetservLportGroup2 OBJECT-GROUP
OBJECTS { frLportNumPlan,
frLportContact,
frLportLocation,
Rehbehn & Fowler Standards Track [Page 64]
RFC 2954 Frame Relay Service MIB October 2000
frLportType,
frLportAddrDLCILen,
frLportVCSigProtocol,
frLportFragControl,
frLportFragSize }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to a Frame Relay Logical Port.
This new version of the Logical Port Group
eliminates the frLportVCSigPointer and adds
support for fragmentation."
::= { frnetservGroups 7 }
frnetservPVCEndptGroup2 OBJECT-GROUP
OBJECTS { frPVCEndptInDiscardsDESet,
frPVCEndptInFramesFECNSet,
frPVCEndptOutFramesFECNSet,
frPVCEndptInFramesBECNSet,
frPVCEndptOutFramesBECNSet,
frPVCEndptInCongDiscards,
frPVCEndptInDECongDiscards,
frPVCEndptOutCongDiscards,
frPVCEndptOutDECongDiscards,
frPVCEndptOutDEFrames,
frPVCEndptAtmIwfConnIndex }
STATUS current
DESCRIPTION
"Additions to the PVC end-point group. These
additions provide new frame counters to track
frame loss. In addition, the new FR/ATM IWF MIB
cross-connect index is included."
::= { frnetservGroups 8 }
frnetservPVCConnectNamesGroup OBJECT-GROUP
OBJECTS { frPVCConnectUserName,
frPVCConnectProviderName }
STATUS current
DESCRIPTION
"Additions to the PVC Connect Group."
::= { frnetservGroups 9 }
frnetservLportAdminGroup OBJECT-GROUP
OBJECTS { frLportDLCIIndexValue,
frLportTypeAdmin,
frLportVCSigProtocolAdmin }
STATUS current
Rehbehn & Fowler Standards Track [Page 65]
RFC 2954 Frame Relay Service MIB October 2000
DESCRIPTION
"Administrative (R/W) objects for creating a
switch logical port."
::= { frnetservGroups 10 }
frnetservMgtVCSigAdminGroup OBJECT-GROUP
OBJECTS { frMgtVCSigProcedAdmin,
frMgtVCSigUserN391Admin,
frMgtVCSigUserN392Admin,
frMgtVCSigUserN393Admin,
frMgtVCSigUserT391Admin,
frMgtVCSigNetN392Admin,
frMgtVCSigNetN393Admin,
frMgtVCSigNetT392Admin,
frMgtVCSigNetnT3Admin }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to the Local In-Channel Signaling
Procedures used for a UNI/NNI logical port."
::= { frnetservGroups 11 }
frnetservPVCNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS { frPVCConnectStatusChange }
STATUS deprecated
DESCRIPTION
"Deprecated notification group. The
frPVCConnectStatusChange notification was flawed
because it included redundant indexes and was not
properly encoded for SMIv1 conversion."
::= { frnetservGroups 12 }
frnetservPVCNotifGroup2 NOTIFICATION-GROUP
NOTIFICATIONS { frPVCConnectStatusNotif }
STATUS current
DESCRIPTION
"A collection of notifications that apply to frame
relay PVC Connections "
::= { frnetservGroups 13 }
END
Rehbehn & Fowler Standards Track [Page 66]
RFC 2954 Frame Relay Service MIB October 2000
4. Acknowledgments
This document was produced by the Frame Relay Service MIB Working
Group.
The working group thanks Bert Wijnen, David Perkins, and Bob Stewart
for their assistance in reviewing the MIB.
5. References
[1] Harrington, D., Presuhn, R. and B. Wijnen, "An Architecture for
Describing SNMP Management Frameworks", RFC 2571, April 1999.
[2] Rose, M. and K. McCloghrie, "Structure and Identification of
Management Information for TCP/IP-based Internets", STD 16, RFC
1155, May 1990.
[3] Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16,
RFC 1212, March 1991.
[4] Rose, M., "A Convention for Defining Traps for use with the
SNMP", RFC 1215, March 1991.
[5] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
M. and S. Waldbusser, "Structure of Management Information
Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.
[6] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
M. and S. Waldbusser, "Textual Conventions for SMIv2", STD 58,
RFC 2579, April 1999.
[7] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
M. and S. Waldbusser, "Conformance Statements for SMIv2", STD
58, RFC 2580, April 1999.
[8] Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple
Network Management Protocol", STD 15, RFC 1157, May 1990.
[9] Case, J., McCloghrie, K., Rose M., and S. Waldbusser,
"Introduction to Community-based SNMPv2", RFC 1901, January
1996.
[10] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Transport
Mappings for Version 2 of the Simple Network Management Protocol
(SNMPv2)", RFC 1906, January 1996.
Rehbehn & Fowler Standards Track [Page 67]
RFC 2954 Frame Relay Service MIB October 2000
[11] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message
Processing and Dispatching for the Simple Network Management
Protocol (SNMP)", RFC 2572, April 1999.
[12] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM)
for version 3 of the Simple Network Management Protocol
(SNMPv3)", RFC 2574, April 1999.
[13] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol
Operations for Version 2 of the Simple Network Management
Protocol (SNMPv2)", RFC 1905, January 1996.
[14] Levi, D., Meyer, P. and B. Stewart, "SNMPv3 Applications", RFC
2573, April 1999.
[15] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access
Control Model (VACM) for the Simple Network Management Protocol
(SNMP)", RFC 2575, April 1999.
[16] Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction
to Version 3 of the Internet-standard Network Management
Framework", RFC 2570, April 1999.
[17] ANSI T1.617-1991, American National Standard for
Telecommunications - Integrated Services Digital Network (ISDN)
- Digital Subscriber Signaling System No. 1 (DSS1) - Signaling
Specification for Frame Relay Bearer Service.
[18] Brown, C. and F. Baker, "Management Information Base for Frame
Relay DTEs", RFC 2115, September 1997.
[19] Brown, C. and A. Malis, "Multi-Protocol Interconnect over Frame
Relay", STD 55, RFC 2427, September 1998.
[20] Fowler, D, "Definitions of Managed Objects for the DS0 and DS0
Bundle Interface Types", RFC 2494, January 1999.
[21] Frame Relay Forum, "Frame Relay Fragmentation Implementation
Agreement", FRF.12, December 1997.
[22] ITU-T Recommendation Q.933,Integrated Services Digital Network
(ISDN) Digital Subscriber Signalling System No. 1 (DSS 1) -
Signalling Specifications for Frame Mode Switched and Permanent
Virtual Connection Control and Status Monitoring, December 1995
Rehbehn & Fowler Standards Track [Page 68]
RFC 2954 Frame Relay Service MIB October 2000
[23] ITU-T Recommendation X.36, Interface Between Data Terminal
Equipment (DTE) and Data Circuit-Terminating Equipment (DCE) For
Public Data Networks Providing Frame Relay Data Transmission
Service By Dedicated Circuit, April 1995
[24] Digital Equipment Corporation, et. al., "Frame Relay
Specification with Extensions Based on Proposed T1S1 Standards",
Revision 1.0, September 18, 1990
[25] ITU-T Recommendation Q.922, Integrated Services Digital Network
(ISDN) Data Link Layer Specification For Frame Mode Bearer
Services, February 1992
[26] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB",
RFC 2863, June 2000.
[27] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
"Management Information Base for Version 2 of the Simple Network
Management Protocol (SNMPv2)", RFC 1907, January 1996.
[28] Rehbehn, K., Nicklass, O. and G. Mouradian, "Definitions of
Managed Objects for Monitoring and Controlling the Frame
Relay/ATM PVC Service Interworking Function", RFC 2955, October
2000.
[29] ITU-T Recommendation E.164/I.331, The International Public
Telecommunication Numbering Plan, May 1997
[30] ITU-T Recommendation X.121, International Numbering Plan For
Public Data Networks, October 1996
[31] Frame Relay Forum, "The Frame Relay Forum User-to-Network
Implementation Agreement (UNI)", FRF 1.2, July 2000.
6. Security Considerations
There are a number of management objects defined in this MIB that
have a MAX-ACCESS clause of read-write and/or read-create. Such
objects may be considered sensitive or vulnerable in some network
environments. The support for SET operations in a non-secure
environment without proper protection can have a negative effect on
network operations.
No managed objects in this MIB contain sensitive information.
Rehbehn & Fowler Standards Track [Page 69]
RFC 2954 Frame Relay Service MIB October 2000
SNMPv1 by itself is not a secure environment. Even if the network
itself is secure (for example by using IPSec), even then, there is no
control as to who on the secure network is allowed to access and
GET/SET (read/change/create/delete) the objects in this MIB.
It is recommended that the implementers consider the security
features as provided by the SNMPv3 framework. Specifically, the use
of the User-based Security Model RFC 2574 [12] and the View-based
Access Control Model RFC 2575 [15] is recommended.
It is then a customer/user responsibility to ensure that the SNMP
entity giving access to an instance of this MIB, is properly
configured to give access to the objects only to those principals
(users) that have legitimate rights to indeed GET or SET
(change/create/delete) them.
7. Authors' Addresses
Kenneth Rehbehn
Megisto Systems, Inc.
20251 Century Boulevard
Germantown, MD, USA 20874
Phone: (301) 515-3672
EMail: krehbehn@megisto.com
David Fowler
Syndesis Limited
28 Fulton Way
Richmond Hill, Ontario, Canada L4B 1J5
Phone: (905) 886-7818
EMail: fowler@syndesis.com
Rehbehn & Fowler Standards Track [Page 70]
RFC 2954 Frame Relay Service MIB October 2000
APPENDIX A Update Information
The changes from RFC 1604 are the following:
(1) Added the object frLportDLCIIndexValue to automatically generate
index values for new DLC rows.
(2) Add the following objects to support manager writing to objects:
Logical Port Objects
frLportTypeAdmin
frLportVCSigProtocolAdmin
VC Objects
frMgtVCSigProcedAdmin
frMgtVCSigUserN391Admin
frMgtVCSigUserN392Admin
frMgtVCSigUserN393Admin
frMgtVCSigUserT391Admin
frMgtVCSigNetN392Admin
frMgtVCSigNetN393Admin
frMgtVCSigNetT392Admin
frMgtVCSigNetnT3Admin
(3) Add objects to control fragmentation:
frLportFragControl frLportFragSize
(4) Added objects to track frames offered to network (in) and
delivered (out) for increased visibility into policing-driven
discards, congestion-driven discards, DE-bit setting, and
congestion bit setting:
frPVCEndptInDiscardsDESet
frPVCEndptInFramesFECNSet
frPVCEndptOutFramesFECNSet
frPVCEndptInFramesBECNSet
frPVCEndptOutFramesBECNSet
frPVCEndptInCongDiscards
frPVCEndptInDECongDiscards
frPVCEndptOutCongDiscards
frPVCEndptOutDECongDiscards
frPVCEndptOutDEFrames
(5) Added the PVC object frPVCEndptAtmIwfConnIndex to identify the
type of connection, frame relay or ATM IWF; and to identify the
cross-connect row of the FR/ATM IWF MIB.
Rehbehn & Fowler Standards Track [Page 71]
RFC 2954 Frame Relay Service MIB October 2000
(6) Added objects to provide printable names of the connection user
and service provider:
frPVCConnectUserName
frPVCConnectProviderName
(7) Added a new notification to correct flaws in the RFC1604 trap.
The flaws include improper OID suffix (SMIv1 compatibility
issue) and the inclusion of redundant index fields
(8) Updated compliance modules and object groups to reflect the new
objects and notification:
frnetservCompliance2 - New service-centric (read-only)
compliance module
frnetSwitchCompliance - New switch-centric (read-write)
compliance module
frnetservCompliance - Original RFC 1604 Module, now
deprecated
frnetservLportGroup - Original RFC 1604 logical port
group, now deprecated
frnetservLportGroup2 - Replacement logical port group
frnetservPVCEndptGroup2 - Extension objects with this
revision of the MIB
frnetservPVCConnectNamesGroup - New group w/ display names
for connections
frnetservLportAdminGroup - New group w/ read-write objects
for the logical port
frnetservMgtVCSigAdminGroup - New group w/ read-write objects
for the signaling protocol
frnetservPVCNotifGroup - Group deprecated to eliminate
obsolete frPVCConnectStatusChange
notification
frnetservPVCNotifGroup2 - New group added with w/
frPVCConnectStatusNotif
(9) Added UNITS and REFERENCE clauses for objects that needed the
clarification.
Rehbehn & Fowler Standards Track [Page 72]
RFC 2954 Frame Relay Service MIB October 2000
(10) Changed references to "proxy-agent" to "FRS agent" to avoid
confusion with other proxy-agent terminology.
(11) Changed objects using the DisplayString TC to use the
SnmpAdminString TC.
(12) frMgtVCSigProced - Expanded to include the u2nuser(3)
enumeration for the UNI protocol operation where the logical
port operates in the user role.
(13) DESCRIPTION text added to specify agent response when object is
not instantiated for the following objects:
frMgtVCSigUserN391
frMgtVCSigUserN393
frMgtVCSigUserT391
frMgtVCSigUserN392
frMgtVCSigNetN391
frMgtVCSigNetN393
frMgtVCSigNetT391
frMgtVCSigNetN392
frMgtVCSigNetnN4
frMgtVCSigNetnT3
frMgtVCSigUserLinkRelErrors
frMgtVCSigUserProtErrors
frMgtVCSigUserChanInactive
(14) DESCRIPTION text addressing case of logical port not performing
network-side procedures was removed from following objects:
frMgtVCSigNetLinkRelErrors
frMgtVCSigNetChanInactive
frMgtVCSigNetProtErrors
(15) frPVCEndptConnectIdentifier - Operation described for the case
of FR/ATM IWF cross-connect operation.
(16) frPVCEndptRcvdSigStatus - Added description of enumerated
values.
(17) frPVCEndptInDiscards - Clarified DESCRIPTION to state that
congestion discards are not counted by object.
(18) frPVCConnect{Low|High}IfIndex - Changed to use InterfaceIndex TC
and changed reference to MIB-II to the new IF-MIB. Removed
statement asserting that a zero value means the port is not a FR
logical port.
Rehbehn & Fowler Standards Track [Page 73]
RFC 2954 Frame Relay Service MIB October 2000
(19) frPVCConnectIndex - Added a range to the SYNTAX clause
(20) frPVCConnect{L2h|H2l}OperStatus - Added DESCRIPTION text for
each enumerated value.
(21) frAccountPVCDLCIIndex - Added a range to the SYNTAX clause
(22) frPVCCOnnectStatusChange Notification - STATUS change to
deprecated. Obsoleted to eliminate inappropriate inclusion of
index objects
(23) frPVCConnectStatusNotif Notification - Replaces
frPVCConnectStatusChange. In addition, the notification now
requires 2 instances of the frPVCEndptRcvdSigStatus object, one
for each endpoint of the connection.
(24) Guidance added to recommend ifLinkUpDownTrapEnable be set on.
(25) Behavior of the PVC status and endpoint signaling status is
clarified for the case of underlying layer failure.
(26) Overview text re-written for clarity.
(27) Clarified role of system group.
(28) Established maximum frame size of 4096 and default value of
1600.
(29) Clarified that DLC index range is restricted to valid range for
the specific length of address field used on the logical port.
(30) Figure 1 and accompanying text was removed to eliminate a
confusing "MIB stack" concept. See the section titled "Relation
to Other MIBs" for replacement text.
Rehbehn & Fowler Standards Track [Page 74]
RFC 2954 Frame Relay Service MIB October 2000
Intellectual Property Rights
The IETF takes no position regarding the validity or scope of any
intellectual property or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; neither does it represent that it
has made any effort to identify any such rights. Information on the
IETF's procedures with respect to rights in standards-track and
standards-related documentation can be found in BCP-11. Copies of
claims of rights made available for publication and any assurances of
licenses to be made available, or the result of an attempt made to
obtain a general license or permission for the use of such
proprietary rights by implementers or users of this specification can
be obtained from the IETF Secretariat.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights which may cover technology that may be required to practice
this standard. Please address the information to the IETF Executive
Director.
Rehbehn & Fowler Standards Track [Page 75]
RFC 2954 Frame Relay Service MIB October 2000
Full Copyright Statement
Copyright (C) The Internet Society (2000). All Rights Reserved.
This document and translations of it may be copied and furnished to
others, and derivative works that comment on or otherwise explain it
or assist in its implementation may be prepared, copied, published
and distributed, in whole or in part, without restriction of any
kind, provided that the above copyright notice and this paragraph are
included on all such copies and derivative works. However, this
document itself may not be modified in any way, such as by removing
the copyright notice or references to the Internet Society or other
Internet organizations, except as needed for the purpose of
developing Internet standards in which case the procedures for
copyrights defined in the Internet Standards process must be
followed, or as required to translate it into languages other than
English.
The limited permissions granted above are perpetual and will not be
revoked by the Internet Society or its successors or assigns.
This document and the information contained herein is provided on an
"AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Rehbehn & Fowler Standards Track [Page 76]
|