1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2876 2877 2878 2879 2880 2881 2882 2883 2884 2885 2886 2887 2888 2889 2890 2891 2892 2893 2894 2895 2896 2897 2898 2899 2900 2901 2902 2903 2904 2905 2906 2907 2908 2909 2910 2911 2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923 2924 2925 2926 2927 2928 2929 2930 2931 2932 2933 2934 2935 2936 2937 2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981 2982 2983 2984 2985 2986 2987 2988 2989 2990 2991 2992 2993 2994 2995 2996 2997 2998 2999 3000 3001 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3013 3014 3015 3016 3017 3018 3019 3020 3021 3022 3023 3024 3025 3026 3027 3028 3029 3030 3031 3032 3033 3034 3035 3036 3037 3038 3039 3040 3041 3042 3043 3044 3045 3046 3047 3048 3049 3050 3051 3052 3053 3054 3055 3056 3057 3058 3059 3060 3061 3062 3063 3064 3065 3066 3067 3068 3069 3070 3071 3072 3073 3074 3075 3076 3077 3078 3079 3080 3081 3082 3083 3084 3085 3086 3087 3088 3089 3090 3091 3092 3093 3094 3095 3096 3097 3098 3099 3100 3101 3102 3103 3104 3105 3106 3107 3108 3109 3110 3111 3112 3113 3114 3115 3116 3117 3118 3119 3120 3121 3122 3123 3124 3125 3126 3127 3128 3129 3130 3131 3132 3133 3134 3135 3136 3137 3138 3139 3140 3141 3142 3143 3144 3145 3146 3147 3148 3149 3150 3151 3152 3153 3154 3155 3156 3157 3158 3159 3160 3161 3162 3163 3164 3165 3166 3167 3168 3169 3170 3171 3172 3173 3174 3175 3176 3177 3178 3179 3180 3181 3182 3183 3184 3185 3186 3187 3188 3189 3190 3191 3192 3193 3194 3195 3196 3197 3198 3199 3200 3201 3202 3203 3204 3205 3206 3207 3208 3209 3210 3211 3212 3213 3214 3215 3216 3217 3218 3219 3220 3221 3222 3223 3224 3225 3226 3227 3228 3229 3230 3231 3232 3233 3234 3235 3236 3237 3238 3239 3240 3241 3242 3243 3244 3245 3246 3247 3248 3249 3250 3251 3252 3253 3254 3255 3256 3257 3258 3259 3260 3261 3262 3263 3264 3265 3266 3267 3268 3269 3270 3271 3272 3273 3274 3275 3276 3277 3278 3279 3280 3281 3282 3283 3284 3285 3286 3287 3288 3289 3290 3291 3292 3293 3294 3295 3296 3297 3298 3299 3300 3301 3302 3303 3304 3305 3306 3307 3308 3309 3310 3311 3312 3313 3314 3315 3316 3317 3318 3319 3320 3321 3322 3323 3324 3325 3326 3327 3328 3329 3330 3331 3332 3333 3334 3335 3336 3337 3338 3339 3340 3341 3342 3343 3344 3345 3346 3347 3348 3349 3350 3351 3352 3353 3354 3355 3356 3357 3358 3359 3360 3361 3362 3363 3364 3365 3366 3367 3368 3369 3370 3371 3372 3373 3374 3375 3376 3377 3378 3379 3380 3381 3382 3383 3384 3385 3386 3387 3388 3389 3390 3391 3392 3393 3394 3395 3396 3397 3398 3399 3400 3401 3402 3403 3404 3405 3406 3407 3408 3409 3410 3411 3412 3413 3414 3415 3416 3417 3418 3419 3420 3421 3422 3423 3424 3425 3426 3427 3428 3429 3430 3431 3432 3433 3434 3435 3436 3437 3438 3439 3440 3441 3442 3443 3444 3445 3446 3447 3448 3449 3450 3451 3452 3453 3454 3455 3456 3457 3458 3459 3460 3461 3462 3463 3464 3465 3466 3467 3468 3469
|
<pre>Network Working Group R. Price
Request for Comments: 3320 Siemens/Roke Manor
Category: Standards Track C. Bormann
TZI/Uni Bremen
J. Christoffersson
H. Hannu
Ericsson
Z. Liu
Nokia
J. Rosenberg
dynamicsoft
January 2003
<span class="h1">Signaling Compression (SigComp)</span>
Status of this Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
Copyright (C) The Internet Society (2003). All Rights Reserved.
Abstract
This document defines Signaling Compression (SigComp), a solution for
compressing messages generated by application protocols such as the
Session Initiation Protocol (SIP) (<a href="./rfc3261">RFC 3261</a>) and the Real Time
Streaming Protocol (RTSP) (<a href="./rfc2326">RFC 2326</a>). The architecture and
prerequisites of SigComp are outlined, along with the format of the
SigComp message.
Decompression functionality for SigComp is provided by a Universal
Decompressor Virtual Machine (UDVM) optimized for the task of running
decompression algorithms. The UDVM can be configured to understand
the output of many well-known compressors such as DEFLATE (<a href="./rfc1951">RFC-1951</a>).
<span class="grey">Price, et. al. Standards Track [Page 1]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-2" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Table of Contents
<a href="#section-1">1</a>. Introduction...................................................<a href="#page-2">2</a>
<a href="#section-2">2</a>. Terminology....................................................<a href="#page-3">3</a>
<a href="#section-3">3</a>. SigComp architecture...........................................<a href="#page-5">5</a>
<a href="#section-4">4</a>. SigComp dispatchers...........................................<a href="#page-15">15</a>
<a href="#section-5">5</a>. SigComp compressor............................................<a href="#page-18">18</a>
<a href="#section-6">6</a>. SigComp state handler.........................................<a href="#page-20">20</a>
<a href="#section-7">7</a>. SigComp message format........................................<a href="#page-23">23</a>
<a href="#section-8">8</a>. Overview of the UDVM..........................................<a href="#page-28">28</a>
<a href="#section-9">9</a>. UDVM instruction set..........................................<a href="#page-37">37</a>
<a href="#section-10">10</a>. Security Considerations.......................................<a href="#page-56">56</a>
<a href="#section-11">11</a>. IANA Considerations...........................................<a href="#page-58">58</a>
<a href="#section-12">12</a>. Acknowledgements..............................................<a href="#page-59">59</a>
<a href="#section-13">13</a>. References....................................................<a href="#page-59">59</a>
<a href="#section-14">14</a>. Authors' Addresses............................................<a href="#page-60">60</a>
<a href="#section-15">15</a>. Full Copyright Statement......................................<a href="#page-62">62</a>
<span class="h2"><a class="selflink" id="section-1" href="#section-1">1</a>. Introduction</span>
Many application protocols used for multimedia communications are
text-based and engineered for bandwidth rich links. As a result the
messages have not been optimized in terms of size. For example,
typical SIP messages range from a few hundred bytes up to two
thousand bytes or more [<a href="./rfc3261">RFC3261</a>].
With the planned usage of these protocols in wireless handsets as
part of 2.5G and 3G cellular networks, the large message size is
problematic. With low-rate IP connectivity the transmission delays
are significant. Taking into account retransmissions, and the
multiplicity of messages that are required in some flows, call setup
and feature invocation are adversely affected. SigComp provides a
means to eliminate this problem by offering robust, lossless
compression of application messages.
This document outlines the architecture and prerequisites of the
SigComp solution, the format of the SigComp message and the Universal
Decompressor Virtual Machine (UDVM) that provides decompression
functionality.
SigComp is offered to applications as a layer between the application
and an underlying transport. The service provided is that of the
underlying transport plus compression. SigComp supports a wide range
of transports including TCP, UDP and SCTP [<a href="./rfc2960" title=""Stream Control Transmission Protocol"">RFC-2960</a>].
<span class="grey">Price, et. al. Standards Track [Page 2]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-3" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h2"><a class="selflink" id="section-2" href="#section-2">2</a>. Terminology</span>
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in <a href="https://www.rfc-editor.org/bcp/bcp14">BCP 14</a>, <a href="./rfc2119">RFC 2119</a>
[<a href="./rfc2119" title=""Key words for use in RFCs to Indicate Requirement Levels"">RFC-2119</a>].
Application
Entity that invokes SigComp and performs the following tasks:
1. Supplying application messages to the compressor dispatcher
2. Receiving decompressed messages from the decompressor
dispatcher
3. Determining the compartment identifier for a decompressed
message.
Bytecode
Machine code that can be executed by a virtual machine.
Compressor
Entity that encodes application messages using a certain
compression algorithm, and keeps track of state that can be used
for compression. The compressor is responsible for ensuring that
the messages it generates can be decompressed by the remote UDVM.
Compressor Dispatcher
Entity that receives application messages, invokes a compressor,
and forwards the resulting SigComp compressed messages to a remote
endpoint.
UDVM Cycles
A measure of the amount of "CPU power" required to execute a UDVM
instruction (the simplest UDVM instructions require a single UDVM
cycle). An upper limit is placed on the number of UDVM cycles
that can be used to decompress each bit in a SigComp message.
Decompressor Dispatcher
Entity that receives SigComp messages, invokes a UDVM, and
forwards the resulting decompressed messages to the application.
<span class="grey">Price, et. al. Standards Track [Page 3]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-4" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Endpoint
One instance of an application, a SigComp layer, and a transport
layer for sending and/or receiving SigComp messages.
Message-based Transport
A transport that carries data as a set of bounded messages.
Compartment
An application-specific grouping of messages that relate to a peer
endpoint. Depending on the signaling protocol, this grouping may
relate to application concepts such as "session", "dialog",
"connection", or "association". The application allocates state
memory on a per-compartment basis, and determines when a
compartment should be created or closed.
Compartment Identifier
An identifier (in a locally chosen format) that uniquely
references a compartment.
SigComp
The overall compression solution, comprising the compressor, UDVM,
dispatchers and state handler.
SigComp Message
A message sent from the compressor dispatcher to the decompressor
dispatcher. In case of a message-based transport such as UDP, a
SigComp message corresponds to exactly one datagram. For a
stream-based transport such as TCP, the SigComp messages are
separated by reserved delimiters.
Stream-based transport
A transport that carries data as a continuous stream with no
message boundaries.
Transport
Mechanism for passing data between two endpoints. SigComp is
capable of sending messages over a wide range of transports
including TCP, UDP and SCTP [<a href="./rfc2960" title=""Stream Control Transmission Protocol"">RFC-2960</a>].
<span class="grey">Price, et. al. Standards Track [Page 4]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-5" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Universal Decompressor Virtual Machine (UDVM)
The machine architecture described in this document. The UDVM is
used to decompress SigComp messages.
State
Data saved for retrieval by later SigComp messages.
State Handler
Entity responsible for accessing and storing state information
once permission is granted by the application.
State Identifier
Reference used to access a previously created item of state.
<span class="h2"><a class="selflink" id="section-3" href="#section-3">3</a>. SigComp Architecture</span>
In the SigComp architecture, compression and decompression is
performed at two communicating endpoints. The layout of a single
endpoint is illustrated in Figure 1:
<span class="grey">Price, et. al. Standards Track [Page 5]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-6" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
+-------------------------------------------------------------------+
| |
| Local application |
| |
+-------------------------------------------------------------------+
| ^ |
Application message & | Decompressed | | Compartment
compartment identifier | message | | identifier
| | |
+-- -- -- -- -- -- -- --|-- -- -- -- -- -- -- --|--|-- -- -- -- -- -+
v | v
| +------------------------+ +----------------------+ |
| | | |
| +--| Compressor | | Decompressor |<-+ |
| | dispatcher | | dispatcher | |
| | | | | | | |
| +------------------------+ +----------------------+ |
| | ^ ^ ^ | |
| | | | |
| | | v | | |
| | +--------------+ +---------------+ | |
| | | | | | +-------+ | v | |
| | | Compressor 1 |<----->|State 1| | +--------------+ |
| | | | | | +-------+ | | | | |
| | +--------------+ | | | Decompressor | |
| | | | State handler |<-->| | | |
| | +--------------+ | | | (UDVM) | |
| | | | | | +-------+ | | | | |
| +->| Compressor 2 |<----->|State 2| | +--------------+ |
| | | | | +-------+ | | |
| +--------------+ +---------------+ SigComp layer |
| | | |
+-| -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --|-+
| |
| SigComp SigComp |
| message message |
v |
+-------------------------------------------------------------------+
| |
| Transport layer |
| |
+-------------------------------------------------------------------+
Figure 1: High-level architectural overview of one SigComp endpoint
<span class="grey">Price, et. al. Standards Track [Page 6]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-7" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Note that SigComp is offered to applications as a layer between the
application and the underlying transport, and so Figure 1 is an
endpoint when viewed from a transport layer perspective. From the
perspective of multi-hop application layer protocols however, SigComp
is applied on a per-hop basis.
The SigComp layer is further decomposed into the following entities:
1. Compressor dispatcher - the interface from the application. The
application supplies the compressor dispatcher with an application
message and a compartment identifier (see <a href="#section-3.1">Section 3.1</a> for further
details). The compressor dispatcher invokes a particular
compressor, which returns a SigComp message to be forwarded to the
remote endpoint.
2. Decompressor dispatcher - the interface towards the application.
The decompressor dispatcher receives a SigComp message and invokes
an instance of the Universal Decompressor Virtual Machine (UDVM).
It then forwards the resulting decompressed message to the
application, which may return a compartment identifier if it
wishes to allow state to be saved for the message.
3. One or more compressors - the entities that convert application
messages into SigComp messages. Distinct compressors are invoked
on a per-compartment basis, using the compartment identifiers
supplied by the application. A compressor receives an application
message from the compressor dispatcher, compresses the message,
and returns a SigComp message to the compressor dispatcher. Each
compressor chooses a certain algorithm to encode the data (e.g.,
DEFLATE).
4. UDVM - the entity that decompresses SigComp messages. Note that
since SigComp can run over an unsecured transport layer, a
separate instance of the UDVM is invoked on a per-message basis.
However, during the decompression process the UDVM may invoke the
state handler to access existing state or create new state.
5. State handler - the entity that can store and retrieve state.
State is information that is stored between SigComp messages,
avoiding the need to upload the data on a per-message basis. For
security purposes it is only possible to create new state with the
permission of the application. State creation and retrieval are
further described in Chapter 6.
<span class="grey">Price, et. al. Standards Track [Page 7]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-8" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
When compressing a bidirectional application protocol the choice to
use SigComp can be made independently in both directions, and
compression in one direction does not necessarily imply compression
in the reverse direction. Moreover, even when two communicating
endpoints send SigComp messages in both directions, there is no need
to use the same compression algorithm in each direction.
Note that a SigComp endpoint can decompress messages from multiple
remote endpoints at different locations in a network, as the
architecture is designed to prevent SigComp messages from one
endpoint interfering with messages from a different endpoint. A
consequence of this design choice is that it is difficult for a
malicious user to disrupt SigComp operation by inserting false
compressed messages on the transport layer.
<span class="h3"><a class="selflink" id="section-3.1" href="#section-3.1">3.1</a>. Requirements on the Application</span>
From an application perspective the SigComp layer appears as a new
transport, with similar behavior to the original transport used to
carry uncompressed data (for example SigComp/UDP behaves similarly to
native UDP).
Mechanisms for discovering whether an endpoint supports SigComp are
beyond the scope of this document.
All SigComp messages contain a prefix (the five most-significant bits
of the first byte are set to one) that does not occur in UTF-8
encoded text messages [<a href="./rfc2279" title=""UTF-8, a transformation format of ISO 10646"">RFC-2279</a>], so for applications which use this
encoding (or ASCII encoding) it is possible to multiplex uncompressed
application messages and SigComp messages on the same port.
Applications can still reserve a new port specifically for SigComp
however (e.g., as part of the discovery mechanism).
If a particular endpoint wishes to be stateful then it needs to
partition its decompressed messages into "compartments" under which
state can be saved. SigComp relies on the application to provide
this partition. So for stateful endpoints a new interface is
required to the application in order to leverage the authentication
mechanisms used by the application itself.
When the application receives a decompressed message it maps the
message to a certain compartment and supplies the compartment
identifier to SigComp. Each compartment is allocated a separate
compressor and a certain amount of memory to store state information,
so the application must assign distinct compartments to distinct
remote endpoints. However it is possible for a local endpoint to
establish several compartments that relate to the same remote
endpoint (this should be avoided where possible as it may waste
<span class="grey">Price, et. al. Standards Track [Page 8]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-9" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
memory and reduce the overall compression ratio, but it does not
cause messages to be incorrectly decompressed). In this case,
reliable stateful operation is possible only if the decompressor does
not lump several messages into one compartment when the compressor
expected them to be assigned different compartments.
The exact format of the compartment identifier is unimportant
provided that different identifiers are given to different
compartments.
Applications that wish to communicate using SigComp in a stateful
fashion should use an authentication mechanism to securely map
decompressed messages to compartment identifiers. They should also
agree on any limits to the lifetime of a compartment, to avoid the
case where an endpoint accesses state information that has already
been deleted.
<span class="h3"><a class="selflink" id="section-3.2" href="#section-3.2">3.2</a>. SigComp feedback mechanism</span>
If a signaling protocol sends SigComp messages in both directions and
there is a one-to-one relationship between the compartments
established by the applications on both ends ("peer compartments"),
the two endpoints can cooperate more closely. In this case, it is
possible to send feedback information that monitors the behavior of
an endpoint and helps to improve the overall compression ratio.
SigComp performs feedback on a request/response basis, so a
compressor makes a feedback request and receives some feedback data
in return. The procedure for requesting and returning feedback in
SigComp is illustrated in Figure 2:
<span class="grey">Price, et. al. Standards Track [Page 9]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-10" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
+---------------------+ +---------------------+
| +-----------------+ | | +-----------------+ |
-->| Compressor |------------------------>| UDVM |<->
| | sending to B | | SigComp message | | | |2
| +-----------------+ | requesting feedback | +-----------------+ |
| ^ 1,9 | | 3 | |
| | | | v |
| +-----------------+ | | +-----------------+ |
| | State | | | | State | |
| | handler | | | | handler | |
| +-----------------+ | | +-----------------+ |
| ^ 8 | | 4 | |
| | | | v |
| +-----------------+ | | +-----------------+ |
| | UDVM | | | | Compressor | |
<->| |<------------------------| sending to A |<--
6| +-----------------+ | SigComp message | +-----------------+ |
| 7 | returning feedback | 5 |
| Endpoint A | | Endpoint B |
+---------------------+ +---------------------+
Figure 2: Steps involved in the transmission of feedback data
The dispatchers, the application and the transport layer are omitted
from the diagram for clarity. Note that the decompressed messages
pass via the decompressor dispatcher to the application; moreover the
SigComp messages transmitted from the compressor to the remote UDVM
are sent via first the compressor dispatcher, followed by the
transport layer and finally the decompressor dispatcher.
The steps for requesting and returning feedback data are described in
more detail below:
1. The compressor that sends messages to Endpoint B piggybacks a
feedback request onto a SigComp message.
2. When the application receives the decompressed message, it may
return the compartment identifier for the message.
3. The UDVM in Endpoint B forwards the requested feedback data to the
state handler.
4. If the UDVM can supply a valid compartment identifier, then the
state handler forwards the feedback data to the appropriate
compressor (namely the compressor sending to Endpoint A).
5. The compressor returns the requested feedback data to Endpoint A
piggybacked onto a SigComp message.
<span class="grey">Price, et. al. Standards Track [Page 10]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-11" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
6. When the application receives the decompressed message, it may
return the compartment identifier for the message.
7. The UDVM in Endpoint A forwards the returned feedback data to the
state handler.
8. If the UDVM can supply a valid compartment identifier, then the
state handler forwards the feedback data to the appropriate
compressor (namely the compressor sending to Endpoint B).
9. The compressor makes use of the returned feedback data.
The detailed role played by each entity in the transmission of
feedback data is explained in subsequent chapters.
<span class="h3"><a class="selflink" id="section-3.3" href="#section-3.3">3.3</a>. SigComp Parameters</span>
An advantage of using a virtual machine for decompression is that
almost all of the implementation flexibility lies in the SigComp
compressors. When receiving SigComp messages an endpoint generally
behaves in a predictable manner.
Note however that endpoints implementing SigComp will typically have
a wide range of capabilities, each offering a different amount of
working memory, processing power etc. In order to support this wide
variation in endpoint capabilities, the following parameters are
provided to modify SigComp behavior when receiving SigComp messages:
decompression_memory_size
state_memory_size
cycles_per_bit
SigComp_version
locally available state (a set containing 0 or more state items)
Each parameter has a minimum value that MUST be offered by all
receiving SigComp endpoints. Moreover, endpoints MAY offer
additional resources if available; these resources can be advertised
to remote endpoints using the SigComp feedback mechanism.
Particular applications may also agree a-priori to offer additional
resources as mandatory (e.g., SigComp for SIP offers a dictionary of
common SIP phrases as a mandatory state item).
Each of the SigComp parameters is described in greater detail below.
<span class="grey">Price, et. al. Standards Track [Page 11]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-12" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h4"><a class="selflink" id="section-3.3.1" href="#section-3.3.1">3.3.1</a>. Memory Size and UDVM Cycles</span>
The decompression_memory_size parameter specifies the amount of
memory available to decompress one SigComp message. (Note that the
term "amount of memory" is used on a conceptual level in order to
specify decompressor behavior and allow resource planning on the side
of the compressor -- an implementation could require additional,
bounded amounts of actual memory resources or could even organize its
memory in a completely different way as long as this does not cause
decompression failures where the conceptual model would not.) A
portion of this memory is used to buffer a SigComp message before it
is decompressed; the remainder is given to the UDVM. Note that the
memory is allocated on a per-message basis and can be reclaimed after
the message has been decompressed. All endpoints implementing
SigComp MUST offer a decompression_memory_size of at least 2048
bytes.
The state_memory_size parameter specifies the number of bytes offered
to a particular compartment for the creation of state. This
parameter is set to 0 if the endpoint is stateless.
Unlike the other SigComp parameters, the state_memory_size is offered
on a per-compartment basis and may vary for different compartments.
The memory for a compartment is reclaimed when the application
determines that the compartment is no longer required.
The cycles_per_bit parameter specifies the number of "UDVM cycles"
available to decompress each bit in a SigComp message. Executing a
UDVM instruction requires a certain number of UDVM cycles; a complete
list of UDVM instructions and their cost in UDVM cycles can be found
in Chapter 9. An endpoint MUST offer a minimum of 16 cycles_per_bit.
Each of the three parameter values MUST be chosen from the limited
set given below, so that the parameters can be efficiently encoded
for transmission using the SigComp feedback mechanism.
The cycles_per_bit parameter is encoded using 2 bits, whilst the
decompression_memory_size and state_memory_size are both encoded
using 3 bits. The bit encodings and their corresponding values are
as follows:
<span class="grey">Price, et. al. Standards Track [Page 12]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-13" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Encoding: cycles_per_bit: Encoding: state_memory_size (bytes):
00 16 000 0
01 32 001 2048
10 64 010 4096
11 128 011 8192
100 16384
101 32768
110 65536
111 131072
The decompression_memory_size is encoded in the same manner as the
state_memory_size, except that the bit pattern 000 cannot be used (as
an endpoint cannot offer a decompression_memory_size of 0 bytes).
<span class="h4"><a class="selflink" id="section-3.3.2" href="#section-3.3.2">3.3.2</a>. SigComp Version</span>
The SigComp_version parameter specifies whether only the basic
version of SigComp is available, or whether an upgraded version is
available offering additional instructions etc. Within the UDVM, it
is available as a 2-byte value, generated by zero-extending the 1-
byte SigComp_version parameter (i.e., the first byte of the 2-byte
value is always zero).
The basic version of SigComp is Version 0x01, which is the version
described in this document.
To ensure backwards compatibility, if a SigComp message is
successfully decompressed by Version 0x01 of SigComp then it will be
successfully decompressed on upgraded versions. Similarly, if the
message triggers a manual decompression failure (see <a href="#section-8.7">Section 8.7</a>),
then it will also continue to do so.
However, messages that cause an unexpected decompression failure on
Version 0x01 of SigComp may be successfully decompressed by upgraded
versions.
The simplest way to upgrade SigComp in a backwards-compatible manner
is to add additional UDVM instructions, as this will not affect the
decompression of SigComp messages compatible with Version 0x01.
Reserved addresses in the UDVM memory (Useful Values, see <a href="#section-7.2">Section</a>
<a href="#section-7.2">7.2</a>) may also be assigned values in future versions of SigComp.
<span class="grey">Price, et. al. Standards Track [Page 13]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-14" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h4"><a class="selflink" id="section-3.3.3" href="#section-3.3.3">3.3.3</a>. Locally Available State Items</span>
A SigComp state item is an item of data that is retained between
SigComp messages. State items can be retrieved and loaded into the
UDVM memory as part of the decompression process, often significantly
improving the compression ratio as the same information does not have
to be uploaded on a per-message basis.
Each endpoint maintains a set of state items where every item is
composed of the following information:
Name: Type of data:
state_identifier 20-byte value
state_length 2-byte value
state_address 2-byte value
state_instruction 2-byte value
minimum_access_length 2-byte value from 6 to 20 inclusive
state_value String of state_length consecutive bytes
State items are typically created at an endpoint upon successful
decompression of a SigComp message. The remote compressor sending
the message makes a state creation request by invoking the
appropriate UDVM instruction, and the state is saved once permission
is granted by the application.
However, an endpoint MAY also wish to offer a set of locally
available state items that have not been uploaded as part of a
SigComp message. For example it might offer well-known decompression
algorithms, dictionaries of common phrases used in a specific
signaling protocol, etc.
Since these state items are established locally without input from a
remote endpoint, they are most useful if publicly documented so that
a wide collection of remote endpoints can determine the data
contained in each state item and how it may be used. Further
Internet Documents and RFCs may be published to describe particular
locally available state items.
Although there are no locally available state items that are
mandatory for every SigComp endpoint, certain state items can be made
mandatory in a specific environment (e.g., the dictionary of common
phrases for a specific signaling protocol could be made mandatory for
that signaling protocol's usage of SigComp). Also, remote endpoints
can indicate their interest in receiving a list of some of the state
items available locally at an endpoint using the SigComp feedback
mechanism.
<span class="grey">Price, et. al. Standards Track [Page 14]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-15" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
It is a matter of local decision for an endpoint what items of
locally available state it advertises; this decision has no influence
on interoperability, but may increase or decrease the efficiency of
the compression achievable between the endpoints.
<span class="h2"><a class="selflink" id="section-4" href="#section-4">4</a>. SigComp Dispatchers</span>
This chapter defines the behavior of the compressor and decompressor
dispatcher. The function of these entities is to provide an
interface between SigComp and its environment, minimizing the effort
needed to integrate SigComp into an existing protocol stack.
<span class="h3"><a class="selflink" id="section-4.1" href="#section-4.1">4.1</a>. Compressor Dispatcher</span>
The compressor dispatcher receives messages from the application and
passes the compressed version of each message to the transport layer.
Note that SigComp invokes compressors on a per-compartment basis, so
when the application provides a message to be compressed it must also
provide a compartment identifier. The compressor dispatcher forwards
the application message to the correct compressor based on the
compartment identifier (invoking a new compressor if a new
compartment identifier is encountered). The compressor returns a
SigComp message that can be passed to the transport layer.
Additionally, the application should indicate to the compressor
dispatcher when it wishes to close a particular compartment, so that
the resources taken by the corresponding compressor can be reclaimed.
<span class="h3"><a class="selflink" id="section-4.2" href="#section-4.2">4.2</a>. Decompressor Dispatcher</span>
The decompressor dispatcher receives messages from the transport
layer and passes the decompressed version of each message to the
application.
To ensure that SigComp can run over an unsecured transport layer, the
decompressor dispatcher invokes a new instance of the UDVM for each
new SigComp message. Resources for the UDVM are released as soon as
the message has been decompressed.
The dispatcher MUST NOT make more than one SigComp message available
to a given instance of the UDVM. In particular, the dispatcher MUST
NOT concatenate two SigComp messages to form a single message.
<span class="grey">Price, et. al. Standards Track [Page 15]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-16" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h4"><a class="selflink" id="section-4.2.1" href="#section-4.2.1">4.2.1</a>. Decompressor Dispatcher Strategies</span>
Once the UDVM has been invoked it is initialized using the SigComp
message of Chapter 7. The message is then decompressed by the UDVM,
returned to the decompressor dispatcher, and passed on to the
receiving application. Note that the UDVM has no awareness of
whether the underlying transport is message-based or stream-based,
and so it always outputs decompressed data as a stream. It is the
responsibility of the dispatcher to provide the decompressed message
to the application in the expected form (i.e., as a stream or as a
distinct, bounded message). The dispatcher knows that the end of a
decompressed message has been reached when the UDVM instruction END-
MESSAGE is invoked (see <a href="#section-9.4.9">Section 9.4.9</a>).
For a stream-based transport, two strategies are therefore possible
for the decompressor dispatcher:
1) The dispatcher collects a complete SigComp message and then
invokes the UDVM. The advantage is that, even in implementations
that have multiple incoming compressed streams, only one instance
of the UDVM is ever required.
2) The dispatcher collects the SigComp header (see <a href="#section-7">Section 7</a>) and
invokes the UDVM; the UDVM stays active while the rest of the
message arrives. The advantage is that there is no need to buffer
up the rest of the message; the message can be decompressed as it
arrives, and any decompressed output can be relayed to the
application immediately.
In general, which of the strategies is used is an implementation
choice.
However, the compressor may want to take advantage of strategy 2 by
expecting that some of the application message is passed on to the
application before the SigComp message is terminated, e.g., by
keeping the UDVM active while expecting the application to
continuously receive decompressed output. This approach ("continuous
mode") invalidates some assumptions of the SigComp security model and
can only be used if the transport itself can provide the required
protection against denial of service attacks. Also, since only
strategy 2 works in this approach, the use of continuous mode
requires previous agreement between the two endpoints.
<span class="h4"><a class="selflink" id="section-4.2.2" href="#section-4.2.2">4.2.2</a>. Record Marking</span>
For a stream-based transport, the dispatcher delimits messages by
parsing the compressed data stream for instances of 0xFF and taking
the following actions:
<span class="grey">Price, et. al. Standards Track [Page 16]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-17" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Occurs in data stream: Action:
0xFF 00 one 0xFF byte in the data stream
0xFF 01 same, but the next byte is quoted (could
be another 0xFF)
: :
0xFF 7F same, but the next 127 bytes are quoted
0xFF 80 to 0xFF FE (reserved for future standardization)
0xFF FF end of SigComp message
The combinations 0xFF01 to 0xFF7F are useful to limit the worst case
expansion of the record marking scheme: the 1 (0xFF01) to 127
(0xFF7F) bytes following the byte combination are copied literally by
the decompressor without taking any special action on 0xFF. (Note
that 0xFF00 is just a special case of this, where zero following
bytes are copied literally.)
In UDVM version 0x01, any occurrence of the combinations 0xFF80 to
0xFFFE that are not protected by quoting causes decompression
failure; the decompressor SHOULD close the stream-based transport in
this case.
<span class="h3"><a class="selflink" id="section-4.3" href="#section-4.3">4.3</a>. Returning a Compartment Identifier</span>
Upon receiving a decompressed message the application may supply the
dispatcher with a compartment identifier. Supplying this identifier
grants permission for the following:
1. Items of state accompanying the decompressed message can be saved
using the state memory reserved for the specified compartment.
2. The feedback data accompanying the decompressed message can be
trusted sufficiently that it can be used when sending SigComp
messages that relate to the compressor's equivalent for the
compartment.
The dispatcher passes the compartment identifier to the UDVM, where
it is used as per the END-MESSAGE instruction (see <a href="#section-9.4.9">Section 9.4.9</a>).
The application uses a suitable authentication mechanism to determine
whether the decompressed message belongs to a legitimate compartment
or not. If the application fails to authenticate the message with
sufficient confidence to allow state to be saved or feedback data to
be trusted, it supplies a "no valid compartment" error to the
dispatcher and the UDVM is terminated without creating any state or
forwarding any feedback data.
<span class="grey">Price, et. al. Standards Track [Page 17]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-18" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h2"><a class="selflink" id="section-5" href="#section-5">5</a>. SigComp Compressor</span>
An important feature of SigComp is that decompression functionality
is provided by a Universal Decompressor Virtual Machine (UDVM). This
means that the compressor can choose any algorithm to generate
compressed SigComp messages, and then upload bytecode for the
corresponding decompression algorithm to the UDVM as part of the
SigComp message.
To help with the implementation and testing of a SigComp endpoint,
further Internet Documents and RFCs may be published to describe
particular compression algorithms.
The overall requirement placed on the compressor is that of
transparency, i.e., the compressor MUST NOT send bytecode which
causes the UDVM to incorrectly decompress a given SigComp message.
The following more specific requirements are also placed on the
compressor (they can be considered particular instances of the
transparency requirement):
1. For robustness, it is recommended that the compressor supply some
form of integrity check (not necessarily of cryptographic
strength) over the application message to ensure that successful
decompression has occurred. A UDVM instruction is provided for
CRC verification; also, another instruction can be used to compute
a SHA-1 cryptographic hash.
2. The compressor MUST ensure that the message can be decompressed
using the resources available at the remote endpoint.
3. If the transport is message-based, then the compressor MUST map
each application message to exactly one SigComp message.
4. If the transport is stream-based but the application defines its
own internal message boundaries, then the compressor SHOULD map
each application message to exactly one SigComp message.
Message boundaries should be preserved over a stream-based transport
so that accidental or malicious damage to one SigComp message does
not affect the decompression of subsequent messages.
Additionally, if the state handler passes some requested feedback to
the compressor, then it SHOULD be returned in the next SigComp
message generated by the compressor (unless the state handler passes
some newer requested feedback before the older feedback has been
sent, in which case the older feedback is deleted).
<span class="grey">Price, et. al. Standards Track [Page 18]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-19" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
If present, the requested feedback item SHOULD be copied unmodified
into the returned_feedback_item field provided in the SigComp
message. Note that there is no need to transmit any requested
feedback item more than once.
The compressor SHOULD also upload the local SigComp parameters to the
remote endpoint, unless the endpoint has indicated that it does not
wish to receive these parameters or the compressor determines that
the parameters have already successfully arrived (see <a href="#section-5.1">Section 5.1</a> for
details of how this can be achieved). The SigComp parameters are
uploaded to the UDVM memory at the remote endpoint as described in
<a href="#section-9.4.9">Section 9.4.9</a>.
<span class="h3"><a class="selflink" id="section-5.1" href="#section-5.1">5.1</a>. Ensuring Successful Decompression</span>
A compressor MUST be certain that all of the data needed to
decompress a SigComp message is available at the receiving endpoint.
One way to ensure this is to send all of the needed information in
every SigComp message (including bytecode to decompress the message).
However, the compression ratio for this method will be relatively
low.
To obtain the best overall compression ratio the compressor needs to
request the creation of new state items at the remote endpoint. The
information saved in these state items can then be accessed by later
SigComp messages, avoiding the need to upload the data on a per-
message basis.
Before the compressor can access saved state however, it must ensure
that the SigComp message carrying the state creation request arrived
successfully at the receiving endpoint. For a reliable transport
(e.g., TCP or SCTP) this is guaranteed. For an unreliable transport
however, the compressor must provide a suitable mechanism itself (see
[<a href="./rfc3321" title=""Signaling Compression (SigComp) - Extended Operations"">RFC-3321</a>] for further details).
The compressor must also ensure that the state item it wishes to
access has not been rejected due to a lack of state memory. This can
be accomplished by checking the state_memory_size parameter using the
SigComp feedback mechanism (see <a href="#section-9.4.9">Section 9.4.9</a> for further details).
<span class="h3"><a class="selflink" id="section-5.2" href="#section-5.2">5.2</a>. Compression Failure</span>
The compressor SHOULD make every effort to successfully compress an
application message, but in certain cases this might not be possible
(particularly if resources are scarce at the receiving endpoint). In
this case a "compression failure" is called.
<span class="grey">Price, et. al. Standards Track [Page 19]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-20" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
If a compression failure occurs then the compressor informs the
dispatcher and takes no further action. The dispatcher MUST report
this failure to the application so that it can try other methods to
deliver the message.
<span class="h2"><a class="selflink" id="section-6" href="#section-6">6</a>. State Handling and Feedback</span>
This chapter defines the behavior of the SigComp state handler. The
function of the state handler is to retain information between
received SigComp messages; it is the only SigComp entity that is
capable of this function, and so it is of particular importance from
a security perspective.
<span class="h3"><a class="selflink" id="section-6.1" href="#section-6.1">6.1</a>. Creating and Accessing State</span>
To provide security against the malicious insertion or modification
of SigComp messages, a separate instance of the UDVM is invoked to
decompress each message. This ensures that damaged SigComp messages
do not prevent the successful decompression of subsequent valid
messages.
Note, however, that the overall compression ratio is often
significantly higher if messages can be compressed relative to the
information contained in previous messages. For this reason, it is
possible to create state items for access when a later message is
being decompressed. Both the creation and access of state are
designed to be secure against malicious tampering with the compressed
data. The UDVM can only create a state item when a complete message
has been successfully decompressed and the application has returned a
compartment identifier under which the state can be saved.
State access cannot be protected by relying on the application alone,
since the authentication mechanism may require information from the
decompressed message (which of course is not available until after
the state has been accessed). Instead, SigComp protects state access
by creating a state identifier that is a hash over the item of state
to be retrieved. This state_identifier must be supplied to retrieve
an item of state from the state handler.
Also note that state is not deleted when it is accessed. So even if
a malicious sender manages to access some state information,
subsequent messages compressed relative to this state can still be
successfully decompressed.
Each state item contains a state_identifier that is used to access
the state. One state identifier can be supplied in the SigComp
message header to initialize the UDVM (see Chapter 7); additional
state items can be retrieved using the STATE-ACCESS instruction. The
<span class="grey">Price, et. al. Standards Track [Page 20]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-21" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
UDVM can also request the creation of a new state item by using the
STATE-CREATE and END-MESSAGE instructions (see Chapter 9 for further
details).
<span class="h3"><a class="selflink" id="section-6.2" href="#section-6.2">6.2</a>. Memory Management</span>
The state handler manages state memory on a per-compartment basis.
Each compartment can store state up to a certain state_memory_size
(where the application may assign different values for the
state_memory_size parameter to different compartments).
As well as storing the state items themselves, the state handler
maintains a list of the state items created by a particular
compartment and ensures that no compartment exceeds its allocated
state_memory_size. For the purpose of calculation, each state item
is considered to cost (state_length + 64) bytes.
Each instance of the UDVM can pass up to four state creation requests
to the state handler, as well as up to four state free requests (the
latter are requests to free the memory taken by a state item in a
certain compartment). When the state handler receives a state
creation request from the UDVM it takes the following steps:
1. The state handler MUST reject all state creation requests that are
not accompanied by a valid compartment identifier, or if the
compartment is allocated 0 bytes of state memory. Note that if a
state creation request fails due to lack of state memory then it
does not mean that the corresponding SigComp message is damaged;
compressors will often make state creation requests in the first
SigComp message of a compartment, before they have discovered the
state_memory_size using the SigComp feedback mechanism.
2. If the state creation request needs more state memory than the
total state_memory_size for the compartment, the state handler
deletes all but the first (state_memory_size - 64) bytes from the
state_value. It sets the state_length to (state_memory_size -
64), and recalculates the state_identifier as defined in <a href="#section-9.4.9">Section</a>
<a href="#section-9.4.9">9.4.9</a>.
3. If the state creation request contains a state_identifier that
already exists then the state handler checks whether the requested
state item is identical to the established state item and counts
the state creation request as successful if this is the case. If
not then the state creation request is unsuccessful (although the
probability that this will occur is vanishingly small).
<span class="grey">Price, et. al. Standards Track [Page 21]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-22" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
4. If the state creation request exceeds the state memory allocated
to the compartment, sufficient items of state created by the same
compartment are freed until enough memory is available to
accommodate the new state. When a state item is freed, it is
removed from the list of states created by the compartment and the
memory cost of the state item no longer counts towards the total
cost for the compartment. Note, however, that identical state
items may be created by several different compartments, so a state
item must not be physically deleted unless the state handler
determines that it is no longer required by any compartment.
5. The order in which the existing state items are freed is
determined by the state_retention_priority, which is set when the
state items are created. The state_retention_priority of 65535 is
reserved for locally available states; these states must always be
freed first. Apart from this special case, states with the lowest
state_retention_priority are always freed first. In the event of
a tie, then the state item created first in the compartment is
also the first to be freed.
The state_retention_priority is always stored on a per-compartment
basis as part of the list of state items created by each compartment.
In particular, the same state item might have several priority values
if it has been created by several different compartments.
Note that locally available state items (as described in <a href="#section-3.3.3">Section</a>
<a href="#section-3.3.3">3.3.3</a>) need not be mapped to any particular compartment. However, if
they are created on a per-compartment basis, then they must not
interfere with the state created at the request of the remote
endpoint. The special state_retention_priority of 65535 is reserved
for locally available state items to ensure that this is the case.
The UDVM may also explicitly request the state handler to free a
specific state item in a compartment. In this case, the state
handler deletes the state item from the list of state items created
by the compartment (as before the state item itself must not be
physically deleted unless the state handler determines that it is not
longer required by any compartment).
The application should indicate to the state handler when it wishes
to close a particular compartment, so that the resources taken by the
corresponding state can be reclaimed.
<span class="grey">Price, et. al. Standards Track [Page 22]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-23" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h3"><a class="selflink" id="section-6.3" href="#section-6.3">6.3</a>. Feedback Data</span>
The SigComp feedback mechanism allows feedback data to be received by
a UDVM and forwarded via the state handler to the correct compressor.
Since this feedback data is retained between SigComp messages, it is
considered to be part of the overall state and can only be forwarded
if accompanied by a valid compartment identifier. If this is the
case, then the state handler forwards the feedback data to the
compressor responsible for sending messages that pertain to the peer
compartment of the specified compartment.
<span class="h2"><a class="selflink" id="section-7" href="#section-7">7</a>. SigComp Message Format</span>
This chapter describes the format of the SigComp message and how the
message is used to initialize the UDVM memory.
Note that the SigComp message is not copied into the UDVM memory as
soon as it arrives; instead, the UDVM indicates when it requires
compressed data using a specific instruction. It then pauses and
waits for the information to be supplied before executing the next
instruction. This means that the UDVM can begin to decompress a
SigComp message before the entire message has been received.
A consequence of the above behavior is that when the UDVM is invoked,
the size of the UDVM memory depends on whether the transport used to
provide the SigComp message is stream-based or message-based. If the
transport is message-based then sufficient memory must be available
to buffer the entire SigComp message before it is passed to the UDVM.
So if the message is n bytes long, then the UDVM memory size is set
to (decompression_memory_size - n), up to a maximum of 65536 bytes.
If the transport is stream-based however, then a fixed-size input
buffer is required to accommodate the stream, independently of the
size of each SigComp message. So, for simplicity, the UDVM memory
size is set to (decompression_memory_size / 2).
As a separate instance of the UDVM is invoked on a per-message basis,
each SigComp message must explicitly indicate its chosen
decompression algorithm as well as any additional information that is
needed to decompress the message (e.g., one or more previously
received messages, a dictionary of common SIP phrases etc.). This
information can either be uploaded as part of the SigComp message or
retrieved from an item of state.
<span class="grey">Price, et. al. Standards Track [Page 23]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-24" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
A SigComp message takes one of two forms depending on whether it
accesses a state item at the receiving endpoint. The two variants of
a SigComp message are given in Figure 3. (The T-bit controls the
format of the returned feedback item and is defined in <a href="#section-7.1">Section 7.1</a>.)
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
+---+---+---+---+---+---+---+---+ +---+---+---+---+---+---+---+---+
| 1 1 1 1 1 | T | len | | 1 1 1 1 1 | T | 0 |
+---+---+---+---+---+---+---+---+ +---+---+---+---+---+---+---+---+
| | | |
: returned feedback item : : returned feedback item :
| | | |
+---+---+---+---+---+---+---+---+ +---+---+---+---+---+---+---+---+
| | | code_len |
: partial state identifier : +---+---+---+---+---+---+---+---+
| | | code_len | destination |
+---+---+---+---+---+---+---+---+ +---+---+---+---+---+---+---+---+
| | | |
: remaining SigComp message : : uploaded UDVM bytecode :
| | | |
+---+---+---+---+---+---+---+---+ +---+---+---+---+---+---+---+---+
| |
: remaining SigComp message :
| |
+---+---+---+---+---+---+---+---+
Figure 3: Format of a SigComp message
Decompression failure occurs if the SigComp message is too short to
contain the expected fields (see <a href="#section-8.7">Section 8.7</a> for further details).
The fields except for the "remaining SigComp message" are referred to
as the "SigComp header" (note that this may include the uploaded UDVM
bytecode).
<span class="h3"><a class="selflink" id="section-7.1" href="#section-7.1">7.1</a>. Returned feedback item</span>
For both variants of the SigComp message, the T-bit is set to 1
whenever the SigComp message contains a returned feedback item. The
format of the returned feedback item is illustrated in Figure 4.
<span class="grey">Price, et. al. Standards Track [Page 24]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-25" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
+---+---+---+---+---+---+---+---+ +---+---+---+---+---+---+---+---+
| 0 | returned_feedback_field | | 1 | returned_feedback_length |
+---+---+---+---+---+---+---+---+ +---+---+---+---+---+---+---+---+
| |
: returned_feedback_field :
| |
+---+---+---+---+---+---+---+---+
Figure 4: Format of returned feedback item
Note that the returned feedback length specifies the size of the
returned feedback field (from 0 to 127 bytes). So the total size of
the returned feedback item lies between 1 and 128 bytes.
The returned feedback item is not copied to the UDVM memory; instead,
it is buffered until the UDVM has successfully decompressed the
SigComp message. It is then forwarded to the state handler with the
rest of the feedback data (see <a href="#section-9.4.9">Section 9.4.9</a> for further details).
<span class="h3"><a class="selflink" id="section-7.2" href="#section-7.2">7.2</a>. Accessing Stored State</span>
The len field of the SigComp message determines which fields follow
the returned feedback item. If the len field is non-zero, then the
SigComp message contains a state identifier to access a state item at
the receiving endpoint. All state items include a 20-byte state
identifier as per <a href="#section-3.3.3">Section 3.3.3</a>, but it is possible to transmit as
few as 6 bytes from the identifier if the sender believes that this
is sufficient to match a unique state item at the receiving endpoint.
The len field encodes the number of transmitted bytes as follows:
Encoding: Length of partial state identifier
01 6 bytes
10 9 bytes
11 12 bytes
The partial state identifier is passed to the state handler, which
compares it with the most significant bytes of the state_identifier
in every currently stored state item. Decompression failure occurs
if no state item is matched or if more than one state item is
matched.
<span class="grey">Price, et. al. Standards Track [Page 25]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-26" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Decompression failure also occurs if exactly one state item is
matched but the state item contains a minimum_access_length greater
than the length of the partial state identifier. This prevents
especially sensitive state items from being accessed maliciously by
brute force guessing of the state_identifier.
If a state item is successfully accessed then the state_value byte
string is copied into the UDVM memory beginning at state_address.
The first 32 bytes of UDVM memory are then initialized to special
values as illustrated in Figure 5.
0 7 8 15
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| UDVM_memory_size | 0 - 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| cycles_per_bit | 2 - 3
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| SigComp_version | 4 - 5
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| partial_state_ID_length | 6 - 7
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| state_length | 8 - 9
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| |
: reserved : 10 - 31
| |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
Figure 5: Initializing Useful Values in UDVM memory
The first five 2-byte words are initialized to contain some values
that might be useful to the UDVM bytecode (Useful Values). Note that
these values are for information only and can be overwritten when
executing the UDVM bytecode without any effect on the endpoint. The
MSBs of each 2-byte word are stored preceding the LSBs.
Addresses 0 to 5 indicate the resources available to the receiving
endpoint. The UDVM memory size is expressed in bytes modulo 2^16, so
in particular, it is set to 0 if the UDVM memory size is 65536 bytes.
The cycles_per_bit is expressed as a 2-byte integer taking the value
16, 32, 64 or 128. The SigComp_version is expressed as a 2-byte
value as per <a href="#section-3.3.2">Section 3.3.2</a>.
Addresses 6 to 9 are initialized to the length of the partial state
identifier, followed by the state_length from the retrieved state
item. Both are expressed as 2-byte values.
<span class="grey">Price, et. al. Standards Track [Page 26]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-27" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Addresses 10 to 31 are reserved and are initialized to 0 for Version
0x01 of SigComp. Future versions of SigComp can use these locations
for additional Useful Values, so a decompressor MUST NOT rely on
these values being zero.
Any remaining addresses in the UDVM memory that have not yet been
initialized MUST be set to 0.
The UDVM then begins executing instructions at the memory address
contained in state_instruction (which is part of the retrieved item
of state). Note that the remaining SigComp message is held by the
decompressor dispatcher until requested by the UDVM.
(Note that the Useful Values are only set at UDVM startup; there is
no special significance to this memory area afterwards. This means
that the UDVM bytecode is free to use these locations for any other
purpose a memory location might be used for; it just has to be aware
they are not necessarily initialized to zero.)
<span class="h3"><a class="selflink" id="section-7.3" href="#section-7.3">7.3</a>. Uploading UDVM bytecode</span>
If the len field is set to 0 then the bytecode needed to decompress
the SigComp message is supplied as part of the message itself. The
12-bit code_len field specifies the size of the uploaded UDVM
bytecode (from 0 to 4095 bytes inclusive); eight most significant
bits are in the first byte, followed by the four least significant
bits in the most significant bits in the second byte. The remaining
bits in the second byte are interpreted as a 4-bit destination field
that specifies the starting memory address to which the bytecode is
copied. The destination field is encoded as follows:
Encoding: Destination address:
0000 reserved
0001 2 * 64 = 128
0010 3 * 64 = 196
0011 4 * 64 = 256
: :
1111 16 * 64 = 1024
Note that the encoding 0000 is reserved for future SigComp versions,
and causes a decompression failure in Version 0x01.
<span class="grey">Price, et. al. Standards Track [Page 27]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-28" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
The UDVM memory is initialized as per Figure 5, except that addresses
6 to 9 inclusive are set to 0 because no state item has been
accessed. The UDVM then begins executing instructions at the memory
address specified by the destination field. As above, the remaining
SigComp message is held by the decompressor dispatcher until needed
by the UDVM.
<span class="h2"><a class="selflink" id="section-8" href="#section-8">8</a>. Overview of the UDVM</span>
Decompression functionality for SigComp is provided by a Universal
Decompressor Virtual Machine (UDVM). The UDVM is a virtual machine
much like the Java Virtual Machine but with a key difference: it is
designed solely for the purpose of running decompression algorithms.
The motivation for creating the UDVM is to provide flexibility when
choosing how to compress a given application message. Rather than
picking one of a small number of pre-negotiated algorithms, the
compressor implementer has the freedom to select an algorithm of
their choice. The compressed data is then combined with a set of
UDVM instructions that allow the original data to be extracted, and
the result is outputted as a SigComp message. Since the UDVM is
optimized specifically for running decompression algorithms, the code
size of a typical algorithm is small (often sub 100 bytes).
Moreover, the UDVM approach does not add significant extra processing
or memory requirements compared to running a fixed preprogrammed
decompression algorithm.
Figure 6 gives a detailed view of the interfaces between the UDVM and
its environment.
<span class="grey">Price, et. al. Standards Track [Page 28]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-29" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
+----------------+ +----------------+
| | Request compressed data | |
| |-------------------------------->| |
| |<--------------------------------| |
| | Provide compressed data | |
| | | |
| | Output decompressed data | Decompressor |
| |-------------------------------->| dispatcher |
| | | |
| | Indicate end of message | |
| |-------------------------------->| |
| |<--------------------------------| |
| UDVM | Provide compartment identifier | |
| | +----------------+
| |
| | +----------------+
| | Request state information | |
| |-------------------------------->| |
| |<--------------------------------| |
| | Provide state information | State |
| | | handler |
| | Make state creation request | |
| |-------------------------------->| |
| | Forward feedback information | |
+----------------+ +----------------+
Figure 6: Interfaces between the UDVM and its environment
Note that once the UDVM has been initialized, additional compressed
data and state information are only provided at the request of a
specific UDVM instruction.
This chapter describes the basic features of the UDVM including the
UDVM registers and the format of UDVM bytecode.
<span class="h3"><a class="selflink" id="section-8.1" href="#section-8.1">8.1</a>. UDVM Registers</span>
The UDVM registers are 2-byte words in the UDVM memory that have
special tasks, for example specifying the location of the stack used
by the CALL and RETURN instructions.
The UDVM registers are illustrated in Figure 7.
<span class="grey">Price, et. al. Standards Track [Page 29]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-30" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
0 7 8 15
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| byte_copy_left | 64 - 65
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| byte_copy_right | 66 - 67
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| input_bit_order | 68 - 69
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| stack_location | 70 - 71
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
Figure 7: Memory addresses of the UDVM registers
The MSBs of each register are always stored before the LSBs. So, for
example, the MSBs of byte_copy_left are stored at Address 64 whilst
the LSBs are stored at Address 65.
The use of each UDVM register is defined in the following sections.
(Note that the UDVM registers start at Address 64, that is 32 bytes
after the area reserved for Useful Values. The intention is that the
gap, i.e., the area between Address 32 and Address 63, will often be
used as scratch-pad memory that is guaranteed to be zero at UDVM
startup and is efficiently addressable in operand types reference ($)
and multitype (%).)
<span class="h3"><a class="selflink" id="section-8.2" href="#section-8.2">8.2</a>. Requesting Additional Compressed Data</span>
The decompressor dispatcher stores the compressed data from the
SigComp message before it is requested by the UDVM via one of the
INPUT instructions. When the UDVM bytecode is first executed, the
dispatcher contains the remaining SigComp message after the header
has been used to initialize the UDVM as per Chapter 7.
Note that the INPUT-BITS and INPUT-HUFFMAN instructions retrieve a
stream of individual compressed bits from the dispatcher. To provide
bitwise compatibility with various well-known compression algorithms,
the input_bit_order register can modify the order in which individual
bits are passed within a byte.
The input_bit_order register contains the following three flags:
0 7 8 15
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| reserved |F|H|P| 68 - 69
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
<span class="grey">Price, et. al. Standards Track [Page 30]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-31" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
The P-bit controls the order in which bits are passed from the
dispatcher to the INPUT instructions. If set to 0, it indicates that
the bits within an individual byte are passed to the INPUT
instructions in MSB to LSB order. If it is set to 1, the bits are
passed in LSB to MSB order.
Note that the input_bit_order register cannot change the order in
which the bytes themselves are passed to the INPUT instructions
(bytes are always passed in the same order as they occur in the
SigComp message).
The following diagram illustrates the order in which bits are passed
to the INPUT instructions for both cases:
MSB LSB MSB LSB MSB LSB MSB LSB
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
|0 1 2 3 4 5 6 7|8 9 ... | |7 6 5 4 3 2 1 0| ... 9 8|
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
Byte 0 Byte 1 Byte 0 Byte 1
P = 0 P = 1
Note that after one or more INPUT instructions the dispatcher may
hold a fraction of a byte (what used to be the LSBs if P = 0, or, the
MSBs, if P = 1). If an INPUT instruction is encountered and the P-
bit has changed since the last INPUT instruction, any fraction of a
byte still held by the dispatcher MUST be discarded (even if the
INPUT instruction requests zero bits). The first bit passed to the
INPUT instruction is taken from the subsequent byte.
When an INPUT instruction requests n bits of compressed data, it
interprets the received bits as an integer between 0 and 2^n - 1.
The F-bit and the H-bit specify whether the bits in these integers
are considered to arrive in MSB to LSB order (bit set to 0) or in LSB
to MSB order (bit set to 1).
If the F-bit is set to 0, the INPUT-BITS instruction interprets the
received bits as arriving MSBs first, and if it is set to 1, it
interprets the bits as arriving LSBs first. The H-bit performs the
same function for the INPUT-HUFFMAN instruction. Note that it is
possible to set these two bits to different values in order to use
different bit orders for the two instructions (certain algorithms
actually require this, e.g., DEFLATE [<a href="./rfc1951" title=""DEFLATE Compressed Data Format Specification version 1.3"">RFC-1951</a>]). (Note that there
are no special considerations for changing the F- or H-bit between
INPUT instructions, unlike the discard rule for the P-bit described
above.)
<span class="grey">Price, et. al. Standards Track [Page 31]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-32" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Decompression failure occurs if an INPUT-BITS or an INPUT-HUFFMAN
instruction is encountered and the input_bit_order register does not
lie between 0 and 7 inclusive.
<span class="h3"><a class="selflink" id="section-8.3" href="#section-8.3">8.3</a>. UDVM Stack</span>
Certain UDVM instructions make use of a stack of 2-byte words stored
at the memory address specified by the 2-byte word stack_location.
The stack contains the following words:
Name: Starting memory address:
stack_fill stack_location
stack[0] stack_location + 2
stack[1] stack_location + 4
stack[2] stack_location + 6
: :
The notation stack_location is an abbreviation for the contents of
the stack_location register, i.e., the 2-byte word at locations 70
and 71. The notation stack_fill is an abbreviation for the 2-byte
word at stack_location and stack_location+1. Similarly, the notation
stack[n] is an abbreviation for the 2-byte word at
stack_location+2*n+2 and stack_location+2*n+3. (As always, the
arithmetic is modulo 2^16.)
The stack is used by the CALL, RETURN, PUSH and POP instructions.
"Pushing" a value on the stack is an abbreviation for copying the
value to stack[stack_fill] and then increasing stack_fill by 1. CALL
and PUSH push values on the stack.
"Popping" a value from the stack is an abbreviation for decreasing
stack_fill by 1, and then using the value stored in
stack[stack_fill]. Decompression failure occurs if stack_fill is
zero at the commencement of a popping operation. POP and RETURN pop
values from the stack.
For both of these abstract operations, the UDVM first takes note of
the current value of stack_location and uses this value for both
sub-operations (accessing the stack and manipulating stack_fill),
i.e., overwriting stack_location in the course of the operation is
inconsequential for the operation.
<span class="grey">Price, et. al. Standards Track [Page 32]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-33" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h3"><a class="selflink" id="section-8.4" href="#section-8.4">8.4</a>. Byte copying</span>
A number of UDVM instructions require a string of bytes to be copied
to and from areas of the UDVM memory. This section defines how the
byte copying operation should be performed.
The string of bytes is copied in ascending order of memory address,
respecting the bounds set by byte_copy_left and byte_copy_right.
More precisely, if a byte is copied from/to Address m then the next
byte is copied from/to Address n where n is calculated as follows:
Set k := m + 1 (modulo 2^16)
If k = byte_copy_right then set n := byte_copy_left, else set n := k
Decompression failure occurs if a byte is copied from/to an address
beyond the UDVM memory.
Note that the string of bytes is copied one byte at a time. In
particular, some of the later bytes to be copied may themselves have
been written into the UDVM memory by the byte copying operation
currently being performed.
Equally, it is possible for a byte copying operation to overwrite the
instruction that invoked the byte copy. If this occurs, then the
byte copying operation MUST be completed as if the original
instruction were still in place in the UDVM memory (this also applies
if byte_copy_left or byte_copy_right are overwritten).
Byte copying is used by the following UDVM instructions:
SHA-1, COPY, COPY-LITERAL, COPY-OFFSET, MEMSET, INPUT-BYTES, STATE-
ACCESS, OUTPUT, END-MESSAGE
<span class="h3"><a class="selflink" id="section-8.5" href="#section-8.5">8.5</a>. Instruction operands and UDVM bytecode</span>
Each of the UDVM instructions in a piece of UDVM bytecode is
represented by a single byte, followed by 0 or more bytes containing
the operands required by the instruction.
During instruction execution, conceptually the UDVM first fetches the
first byte of the instruction, determines the number and types of
operands required for this instruction, and then decodes all the
operands in sequence before starting to act on the instruction.
(Note that the UDVM instructions have been designed in such a way
that this sequence remains conceptual in those cases where it would
result in an unreasonable burden on the implementation.)
<span class="grey">Price, et. al. Standards Track [Page 33]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-34" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
To reduce the size of typical UDVM bytecode, each operand for a UDVM
instruction is compressed using variable-length encoding. The aim is
to store more common operand values using fewer bytes than rarely
occurring values.
Four different types of operand are available: the literal, the
reference, the multitype and the address. Chapter 9 gives a complete
list of UDVM instructions and the operand types that follow each
instruction.
The UDVM bytecode for each operand type is illustrated in Figure 8 to
Figure 10, together with the integer values represented by the
bytecode.
Note that the MSBs in the bytecode are illustrated as preceding the
LSBs. Also, any string of bits marked with k consecutive "n"s is to
be interpreted as an integer N from 0 to 2^k - 1 inclusive (with the
MSBs of n illustrated as preceding the LSBs).
The decoded integer value of the bytecode can be interpreted in two
ways. In some cases it is taken to be the actual value of the
operand. In other cases it is taken to be a memory address at which
the 2-byte operand value can be found (MSBs found at the specified
address, LSBs found at the following address). The latter cases are
denoted by memory[X] where X is the address and memory[X] is the 2-
byte value starting at Address X.
The simplest operand type is the literal (#), which encodes a
constant integer from 0 to 65535 inclusive. A literal operand may
require between 1 and 3 bytes depending on its value.
Bytecode: Operand value: Range:
0nnnnnnn N 0 - 127
10nnnnnn nnnnnnnn N 0 - 16383
11000000 nnnnnnnn nnnnnnnn N 0 - 65535
Figure 8: Bytecode for a literal (#) operand
The second operand type is the reference ($), which is always used to
access a 2-byte value located elsewhere in the UDVM memory. The
bytecode for a reference operand is decoded to be a constant integer
from 0 to 65535 inclusive, which is interpreted as the memory address
containing the actual value of the operand.
<span class="grey">Price, et. al. Standards Track [Page 34]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-35" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Bytecode: Operand value: Range:
0nnnnnnn memory[2 * N] 0 - 65535
10nnnnnn nnnnnnnn memory[2 * N] 0 - 65535
11000000 nnnnnnnn nnnnnnnn memory[N] 0 - 65535
Figure 9: Bytecode for a reference ($) operand
Note that the range of a reference operand is always 0 - 65535
independently of how many bits are used to encode the reference,
because the operand always references a 2-byte value in the memory.
The third kind of operand is the multitype (%), which can be used to
encode both actual values and memory addresses. The multitype
operand also offers efficient encoding for small integer values (both
positive and negative) and for powers of 2.
Bytecode: Operand value: Range:
00nnnnnn N 0 - 63
01nnnnnn memory[2 * N] 0 - 65535
1000011n 2 ^ (N + 6) 64 , 128
10001nnn 2 ^ (N + 8) 256 , ... , 32768
111nnnnn N + 65504 65504 - 65535
1001nnnn nnnnnnnn N + 61440 61440 - 65535
101nnnnn nnnnnnnn N 0 - 8191
110nnnnn nnnnnnnn memory[N] 0 - 65535
10000000 nnnnnnnn nnnnnnnn N 0 - 65535
10000001 nnnnnnnn nnnnnnnn memory[N] 0 - 65535
Figure 10: Bytecode for a multitype (%) operand
The fourth operand type is the address (@). This operand is decoded
as a multitype operand followed by a further step: the memory address
of the UDVM instruction containing the address operand is added to
obtain the correct operand value. So if the operand value from
Figure 10 is D then the actual operand value of an address is
calculated as follows:
operand_value = (memory_address_of_instruction + D) modulo 2^16
Address operands are always used in instructions that control program
flow, because they ensure that the UDVM bytecode is position-
independent code (i.e., it will run independently of where it is
placed in the UDVM memory).
<span class="grey">Price, et. al. Standards Track [Page 35]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-36" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h3"><a class="selflink" id="section-8.6" href="#section-8.6">8.6</a>. UDVM Cycles</span>
Once the UDVM has been invoked it executes the instructions contained
in its memory consecutively unless otherwise indicated (for example
when the UDVM encounters a JUMP instruction). If the next
instruction to be executed lies outside the available memory then
decompression failure occurs (see <a href="#section-8.7">Section 8.7</a>).
To ensure that a SigComp message cannot consume excessive processing
resources, SigComp limits the number of "UDVM cycles" allocated to
each message. The number of available UDVM cycles is initialized to
1000 plus the number of bits in the SigComp header (as described in
<a href="#section-7">Section 7</a>); this sum is then multiplied by cycles_per_bit. Each time
an instruction is executed the number of available UDVM cycles is
decreased by the amount specified in Chapter 9. Additionally, if the
UDVM successfully requests n bits of compressed data using one of the
INPUT instructions then the number of available UDVM cycles is
increased by n * cycles_per_bit once the instruction has been
executed.
This means that the maximum number of UDVM cycles available for
processing an n-byte SigComp message is given by the formula:
maximum_UDVM_cycles = (8 * n + 1000) * cycles_per_bit
The reason that this total is not allocated to the UDVM when it is
invoked is that the UDVM can begin to decompress a message that has
only been partially received. So the total message size may not be
known when the UDVM is initialized.
Note that the number of UDVM cycles MUST NOT be increased if a
request for additional compressed data fails.
The UDVM stops executing instructions when it encounters an END-
MESSAGE instruction or if decompression failure occurs (see <a href="#section-8.7">Section</a>
<a href="#section-8.7">8.7</a> for further details).
<span class="h3"><a class="selflink" id="section-8.7" href="#section-8.7">8.7</a>. Decompression Failure</span>
If a compressed message given to the UDVM is corrupted (either
accidentally or maliciously), then the UDVM may terminate with a
decompression failure.
<span class="grey">Price, et. al. Standards Track [Page 36]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-37" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Reasons for decompression failure include the following:
1. A SigComp message contains an invalid header as per Chapter 7.
2. A SigComp message is larger than the decompression_memory_size.
3. An instruction costs more than the number of remaining UDVM
cycles.
4. The UDVM attempts to read from or write to a memory address beyond
its memory size.
5. An unknown instruction is encountered.
6. An unknown operand is encountered.
7. An instruction is encountered that cannot be processed
successfully by the UDVM (for example a RETURN instruction when no
CALL instruction has previously been encountered).
8. A request to access some state information fails.
9. A manual decompression failure is triggered using the
DECOMPRESSION-FAILURE instruction.
If a decompression failure occurs when decompressing a message then
the UDVM informs the dispatcher and takes no further action. It is
the responsibility of the dispatcher to decide how to cope with the
decompression failure. In general a dispatcher SHOULD discard the
compressed message (or the compressed stream if the transport is
stream-based) and any decompressed data that has been outputted but
not yet passed to the application.
<span class="h2"><a class="selflink" id="section-9" href="#section-9">9</a>. UDVM Instruction Set</span>
The UDVM currently understands 36 instructions, chosen to support the
widest possible range of compression algorithms with the minimum
possible overhead.
Figure 11 lists the different instructions and the bytecode values
used to encode the instructions. The cost of each instruction in
UDVM cycles is also given:
<span class="grey">Price, et. al. Standards Track [Page 37]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-38" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Instruction: Bytecode value: Cost in UDVM cycles:
DECOMPRESSION-FAILURE 0 1
AND 1 1
OR 2 1
NOT 3 1
LSHIFT 4 1
RSHIFT 5 1
ADD 6 1
SUBTRACT 7 1
MULTIPLY 8 1
DIVIDE 9 1
REMAINDER 10 1
SORT-ASCENDING 11 1 + k * (ceiling(log2(k)) + n)
SORT-DESCENDING 12 1 + k * (ceiling(log2(k)) + n)
SHA-1 13 1 + length
LOAD 14 1
MULTILOAD 15 1 + n
PUSH 16 1
POP 17 1
COPY 18 1 + length
COPY-LITERAL 19 1 + length
COPY-OFFSET 20 1 + length
MEMSET 21 1 + length
JUMP 22 1
COMPARE 23 1
CALL 24 1
RETURN 25 1
SWITCH 26 1 + n
CRC 27 1 + length
INPUT-BYTES 28 1 + length
INPUT-BITS 29 1
INPUT-HUFFMAN 30 1 + n
STATE-ACCESS 31 1 + state_length
STATE-CREATE 32 1 + state_length
STATE-FREE 33 1
OUTPUT 34 1 + output_length
END-MESSAGE 35 1 + state_length
Figure 11: UDVM instructions and corresponding bytecode values
Each UDVM instruction costs a minimum of 1 UDVM cycle. Certain
instructions may cost additional cycles depending on the values of
the instruction operands. Named variables in the cost expressions
refer to the values of the instruction operands with these names.
Note that for the SORT instructions, the formula ceiling(log2(k))
calculates the smallest value i such that k <= 2^i.
<span class="grey">Price, et. al. Standards Track [Page 38]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-39" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
The UDVM instruction set offers a mix of low-level and high-level
instructions. The high-level instructions can all be emulated using
combinations of low-level instructions, but given a choice it is
generally preferable to use a single instruction rather than a large
number of general-purpose instructions. The resulting bytecode will
be more compact (leading to a higher overall compression ratio) and
decompression will typically be faster because the implementation of
the high-level instructions can be more easily optimized.
All instructions are encoded as a single byte to indicate the
instruction type, followed by 0 or more bytes containing the operands
required by the instruction. The instruction specifies which of the
four operand types of <a href="#section-8.5">Section 8.5</a> is used in each case. For example
the ADD instruction is followed by two operands:
ADD ($operand_1, %operand_2)
When converted into bytecode the number of bytes required by the ADD
instruction depends on the value of each operand, and whether the
multitype operand contains the operand value itself or a memory
address where the actual value of the operand can be found.
Each instruction is explained in more detail below.
Whenever the description of an instruction uses the expression "and
then", the intended semantics is that the effect explained before
"and then" is completed before work on the effect explained after the
"and then" is commenced.
<span class="h3"><a class="selflink" id="section-9.1" href="#section-9.1">9.1</a>. Mathematical Instructions</span>
The following instructions provide a number of mathematical
operations including bit manipulation, arithmetic and sorting.
<span class="h4"><a class="selflink" id="section-9.1.1" href="#section-9.1.1">9.1.1</a>. Bit Manipulation</span>
The AND, OR, NOT, LSHIFT and RSHIFT instructions provide simple bit
manipulation on 2-byte words.
AND ($operand_1, %operand_2)
OR ($operand_1, %operand_2)
NOT ($operand_1)
LSHIFT ($operand_1, %operand_2)
RSHIFT ($operand_1, %operand_2)
<span class="grey">Price, et. al. Standards Track [Page 39]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-40" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
After the operation is complete, the value of the first operand is
overwritten with the result. (Note that since this operand is a
reference, it is the 2-byte word at the memory address specified by
the operand that is overwritten.)
The precise definitions of LSHIFT and RSHIFT are given below. Note
that m and n are the 2-byte values encoded by the operands, and that
floor(x) calculates the largest integer not greater than x:
LSHIFT (m, n) := m * 2^n (modulo 2^16)
RSHIFT (m, n) := floor(m / 2^n)
<span class="h4"><a class="selflink" id="section-9.1.2" href="#section-9.1.2">9.1.2</a>. Arithmetic</span>
The ADD, SUBTRACT, MULTIPLY, DIVIDE and REMAINDER instructions
perform arithmetic on 2-byte words.
ADD ($operand_1, %operand_2)
SUBTRACT ($operand_1, %operand_2)
MULTIPLY ($operand_1, %operand_2)
DIVIDE ($operand_1, %operand_2)
REMAINDER ($operand_1, %operand_2)
After the operation is complete, the value of the first operand is
overwritten with the result.
The precise definition of each instruction is given below:
ADD (m, n) := m + n (modulo 2^16)
SUBTRACT (m, n) := m - n (modulo 2^16)
MULTIPLY (m, n) := m * n (modulo 2^16)
DIVIDE (m, n) := floor(m / n)
REMAINDER (m, n) := m - n * floor(m / n)
Decompression failure occurs if a DIVIDE or REMAINDER instruction
encounters an operand_2 that is zero.
<span class="h4"><a class="selflink" id="section-9.1.3" href="#section-9.1.3">9.1.3</a>. Sorting</span>
The SORT-ASCENDING and SORT-DESCENDING instructions sort lists of 2-
byte words.
SORT-ASCENDING (%start, %n, %k)
SORT-DESCENDING (%start, %n, %k)
The start operand specifies the starting memory address of the block
of data to be sorted.
<span class="grey">Price, et. al. Standards Track [Page 40]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-41" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
The block of data itself is divided into n lists each containing k
2-byte words. The SORT-ASCENDING instruction applies a certain
permutation to the lists, such that the first list is sorted into
ascending order (treating each 2-byte word as an unsigned integer).
The same permutation is applied to all n lists, so lists other than
the first will not necessarily be sorted into order.
In the case that two words have the same value, the original ordering
of the list is preserved.
For example, the first list might contain a set of integers to be
sorted whilst the second list might be used to keep track of where
the integers appear in the sorted list:
Before sorting After sorting
List 1 List 2 List 1 List 2
8 1 1 2
1 2 1 3
1 3 3 4
3 4 8 1
The SORT-DESCENDING instruction behaves as above, except that the
first list is sorted into descending order.
<span class="h4"><a class="selflink" id="section-9.1.4" href="#section-9.1.4">9.1.4</a>. SHA-1</span>
The SHA-1 instruction calculates a 20-byte SHA-1 hash [<a href="./rfc3174" title=""US Secure Hash Algorithm 1 (SHA1)"">RFC-3174</a>] over
the specified area of UDVM memory.
SHA-1 (%position, %length, %destination)
The position and length operands specify the starting memory address
and the length of the byte string over which the SHA-1 hash is
calculated. Byte copying rules are enforced as per <a href="#section-8.4">Section 8.4</a>.
The destination operand gives the starting address to which the
resulting 20-byte hash will be copied. Byte copying rules are
enforced as above.
<span class="h3"><a class="selflink" id="section-9.2" href="#section-9.2">9.2</a>. Memory Management Instructions</span>
The following instructions are used to set up the UDVM memory, and to
copy byte strings from one memory location to another.
<span class="grey">Price, et. al. Standards Track [Page 41]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-42" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h4"><a class="selflink" id="section-9.2.1" href="#section-9.2.1">9.2.1</a>. LOAD</span>
The LOAD instruction sets a 2-byte word to a certain specified value.
The format of a LOAD instruction is as follows:
LOAD (%address, %value)
The first operand specifies the starting address of a 2-byte word,
whilst the second operand specifies the value to be loaded into this
word. As usual, MSBs are stored before LSBs in the UDVM memory.
<span class="h4"><a class="selflink" id="section-9.2.2" href="#section-9.2.2">9.2.2</a>. MULTILOAD</span>
The MULTILOAD instruction sets a contiguous block of 2-byte words in
the UDVM memory to specified values.
MULTILOAD (%address, #n, %value_0, ..., %value_n-1)
The first operand specifies the starting address of the contiguous
2-byte words, whilst the operands value_0 through to value_n-1
specify the values to load into these words (in the same order as
they appear in the instruction).
Decompression failure occurs if the set of 2-byte words set by the
instruction would overlap the memory locations held by the
instruction (including its operands) itself, i.e., if the instruction
would be self-modifying. (This restriction makes it simpler to
implement MULTILOAD step-by-step instead of having to decode all
operands before being able to copy data, as is implied by the
conceptual model of instruction execution.)
<span class="h4"><a class="selflink" id="section-9.2.3" href="#section-9.2.3">9.2.3</a>. PUSH and POP</span>
The PUSH and POP instructions read from and write to the UDVM stack
(as defined in <a href="#section-8.3">Section 8.3</a>).
PUSH (%value)
POP (%address)
The PUSH instruction pushes the value specified by its operand on the
stack.
The POP instruction pops a value from the stack and then copies the
value to the specified memory address. (Note that the expression
"and then" implies that the copying of the value is inconsequential
for the stack operation itself, which happens beforehand.)
See <a href="#section-8.3">Section 8.3</a> for possible error conditions.
<span class="grey">Price, et. al. Standards Track [Page 42]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-43" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h4"><a class="selflink" id="section-9.2.4" href="#section-9.2.4">9.2.4</a>. COPY</span>
The COPY instruction is used to copy a string of bytes from one part
of the UDVM memory to another.
COPY (%position, %length, %destination)
The position operand specifies the memory address of the first byte
in the string to be copied, and the length operand specifies the
number of bytes to be copied.
The destination operand gives the address to which the first byte in
the string will be copied.
Byte copying is performed as per the rules of <a href="#section-8.4">Section 8.4</a>.
<span class="h4"><a class="selflink" id="section-9.2.5" href="#section-9.2.5">9.2.5</a>. COPY-LITERAL</span>
A modified version of the COPY instruction is given below:
COPY-LITERAL (%position, %length, $destination)
The COPY-LITERAL instruction behaves as a COPY instruction except
that after copying is completed, the value of the destination operand
is replaced by the address to which the next byte of data would be
copied. More precisely it is replaced by the value n, derived as per
<a href="#section-8.4">Section 8.4</a> with m set to the destination address of the last byte to
be copied, if any (i.e., if the value of the length operand is zero,
the value of the destination operand is not changed).
<span class="h4"><a class="selflink" id="section-9.2.6" href="#section-9.2.6">9.2.6</a>. COPY-OFFSET</span>
A further version of the COPY-LITERAL instruction is given below:
COPY-OFFSET (%offset, %length, $destination)
The COPY-OFFSET instruction behaves as a COPY-LITERAL instruction
except that an offset operand is given instead of a position operand.
To derive the value of the position operand, starting at the memory
address specified by destination, the UDVM counts backwards a total
of offset memory addresses.
If the memory address specified in byte_copy_left is reached, the
next memory address is taken to be (byte_copy_right - 1) modulo 2^16.
<span class="grey">Price, et. al. Standards Track [Page 43]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-44" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
The COPY-OFFSET instruction then behaves as a COPY-LITERAL
instruction, taking the value of the position operand to be the last
memory address reached in the above step.
<span class="h4"><a class="selflink" id="section-9.2.7" href="#section-9.2.7">9.2.7</a>. MEMSET</span>
The MEMSET instruction initializes an area of UDVM memory to a
specified sequence of values. The format of a MEMSET instruction is
as follows:
MEMSET (%address, %length, %start_value, %offset)
The sequence of values used by the MEMSET instruction is specified by
the following formula:
Seq[n] := (start_value + n * offset) modulo 256
The values Seq[0] to Seq[length - 1] inclusive are each interpreted
as a single byte, and then concatenated to form a byte string where
the first byte has value Seq[0], the second byte has value Seq[1] and
so on up to the last byte which has value Seq[length - 1].
The string is then byte copied into the UDVM memory beginning at the
memory address specified as an operand to the MEMSET instruction,
obeying the rules of <a href="#section-8.4">Section 8.4</a>. (Note that the byte string may
overwrite the MEMSET instruction or its operands; as explained in
<a href="#section-8.5">Section 8.5</a>, the MEMSET instruction must be executed as if the
original operands were still in place in the UDVM memory.)
<span class="h3"><a class="selflink" id="section-9.3" href="#section-9.3">9.3</a>. Program Flow Instructions</span>
The following instructions alter the flow of UDVM code. Each
instruction jumps to one of a number of memory addresses based on a
certain specified criterion.
Note that certain I/O instructions (see <a href="#section-9.4">Section 9.4</a>) can also alter
program flow.
<span class="h4"><a class="selflink" id="section-9.3.1" href="#section-9.3.1">9.3.1</a>. JUMP</span>
The JUMP instruction moves program execution to the specified memory
address.
JUMP (@address)
Decompression failure occurs if the value of the address operand lies
beyond the overall UDVM memory size.
<span class="grey">Price, et. al. Standards Track [Page 44]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-45" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h4"><a class="selflink" id="section-9.3.2" href="#section-9.3.2">9.3.2</a>. COMPARE</span>
The COMPARE instruction compares two operands and then jumps to one
of three specified memory addresses depending on the result.
COMPARE (%value_1, %value_2, @address_1, @address_2, @address_3)
If value_1 < value_2 then the UDVM continues instruction execution at
the memory address specified by address 1. If value_1 = value_2 then
it jumps to the address specified by address_2. If value_1 > value_2
then it jumps to the address specified by address_3.
<span class="h4"><a class="selflink" id="section-9.3.3" href="#section-9.3.3">9.3.3</a>. CALL and RETURN</span>
The CALL and RETURN instructions provide support for compression
algorithms with a nested structure.
CALL (@address)
RETURN
Both instructions use the UDVM stack of <a href="#section-8.3">Section 8.3</a>. When the UDVM
reaches a CALL instruction, it finds the memory address of the
instruction immediately following the CALL instruction and pushes
this 2-byte value on the stack, ready for later retrieval. It then
continues instruction execution at the memory address specified by
the address operand.
When the UDVM reaches a RETURN instruction it pops a value from the
stack and then continues instruction execution at the memory address
just popped.
See <a href="#section-8.3">Section 8.3</a> for error conditions.
<span class="h4"><a class="selflink" id="section-9.3.4" href="#section-9.3.4">9.3.4</a>. SWITCH</span>
The SWITCH instruction performs a conditional jump based on the value
of one of its operands.
SWITCH (#n, %j, @address_0, @address_1, ... , @address_n-1)
When a SWITCH instruction is encountered the UDVM reads the value of
j. It then continues instruction execution at the address specified
by address j.
Decompression failure occurs if j specifies a value of n or more, or
if the address lies beyond the overall UDVM memory size.
<span class="grey">Price, et. al. Standards Track [Page 45]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-46" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h4"><a class="selflink" id="section-9.3.5" href="#section-9.3.5">9.3.5</a>. CRC</span>
The CRC instruction verifies a string of bytes using a 2-byte CRC.
CRC (%value, %position, %length, @address)
The actual CRC calculation is performed using the generator
polynomial x^16 + x^12 + x^5 + 1, which coincides with the 2-byte
Frame Check Sequence (FCS) of PPP [<a href="./rfc1662" title=""PPP in HDLC-like Framing"">RFC-1662</a>].
The position and length operands define the string of bytes over
which the CRC is evaluated. Byte copying rules are enforced as per
<a href="#section-8.4">Section 8.4</a>.
The CRC value is computed exactly as defined for the 16-bit FCS
calculation in [<a href="./rfc1662" title=""PPP in HDLC-like Framing"">RFC-1662</a>].
The value operand contains the expected integer value of the 2-byte
CRC. If the calculated CRC matches the expected value then the UDVM
continues instruction execution at the following instruction.
Otherwise the UDVM jumps to the memory address specified by the
address operand.
<span class="h3"><a class="selflink" id="section-9.4" href="#section-9.4">9.4</a>. I/O instructions</span>
The following instructions allow the UDVM to interface with its
environment. Note that in the overall SigComp architecture all of
these interfaces pass to the decompressor dispatcher or to the state
handler.
<span class="h4"><a class="selflink" id="section-9.4.1" href="#section-9.4.1">9.4.1</a>. DECOMPRESSION-FAILURE</span>
The DECOMPRESSION-FAILURE instruction triggers a manual decompression
failure. This is useful if the UDVM bytecode discovers that it
cannot successfully decompress the message (e.g., by using the CRC
instruction).
This instruction has no operands.
<span class="h4"><a class="selflink" id="section-9.4.2" href="#section-9.4.2">9.4.2</a>. INPUT-BYTES</span>
The INPUT-BYTES instruction requests a certain number of bytes of
compressed data from the decompressor dispatcher.
INPUT-BYTES (%length, %destination, @address)
<span class="grey">Price, et. al. Standards Track [Page 46]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-47" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
The length operand indicates the requested number of bytes of
compressed data, and the destination operand specifies the starting
memory address to which they should be copied. Byte copying is
performed as per the rules of <a href="#section-8.4">Section 8.4</a>.
If the instruction requests data that lies beyond the end of the
SigComp message, no data is returned. Instead the UDVM moves program
execution to the address specified by the address operand.
If the INPUT-BYTES is encountered after an INPUT-BITS or an INPUT-
HUFFMAN instruction has been used, and the dispatcher currently holds
a fraction of a byte, then the fraction MUST be discarded before any
data is passed to the UDVM. The first byte to be passed is the byte
immediately following the discarded data.
<span class="h4"><a class="selflink" id="section-9.4.3" href="#section-9.4.3">9.4.3</a>. INPUT-BITS</span>
The INPUT-BITS instruction requests a certain number of bits of
compressed data from the decompressor dispatcher.
INPUT-BITS (%length, %destination, @address)
The length operand indicates the requested number of bits.
Decompression failure occurs if this operand does not lie between 0
and 16 inclusive.
The destination operand specifies the memory address to which the
compressed data should be copied. Note that the requested bits are
interpreted as a 2-byte integer ranging from 0 to 2^length - 1, as
explained in <a href="#section-8.2">Section 8.2</a>.
If the instruction requests data that lies beyond the end of the
SigComp message, no data is returned. Instead the UDVM moves program
execution to the address specified by the address operand.
<span class="h4"><a class="selflink" id="section-9.4.4" href="#section-9.4.4">9.4.4</a>. INPUT-HUFFMAN</span>
The INPUT-HUFFMAN instruction requests a variable number of bits of
compressed data from the decompressor dispatcher. The instruction
initially requests a small number of bits and compares the result
against a certain criterion; if the criterion is not met, then
additional bits are requested until the criterion is achieved.
The INPUT-HUFFMAN instruction is followed by three mandatory operands
plus n additional sets of operands. Every additional set contains
four operands as shown below:
<span class="grey">Price, et. al. Standards Track [Page 47]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-48" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
INPUT-HUFFMAN (%destination, @address, #n, %bits_1, %lower_bound_1,
%upper_bound_1, %uncompressed_1, ... , %bits_n, %lower_bound_n,
%upper_bound_n, %uncompressed_n)
Note that if n = 0 then the INPUT-HUFFMAN instruction is ignored and
program execution resumes at the following instruction.
Decompression failure occurs if (bits_1 + ... + bits_n) > 16.
In all other cases, the behavior of the INPUT-HUFFMAN instruction is
defined below:
1. Set j := 1 and set H := 0.
2. Request bits_j compressed bits. Interpret the returned bits as an
integer k from 0 to 2^bits_j - 1, as explained in <a href="#section-8.2">Section 8.2</a>.
3. Set H := H * 2^bits_j + k.
4. If data is requested that lies beyond the end of the SigComp
message, terminate the INPUT-HUFFMAN instruction and move program
execution to the memory address specified by the address operand.
5. If (H < lower_bound_j) or (H > upper_bound_j) then set j := j + 1.
Then go back to Step 2, unless j > n in which case decompression
failure occurs.
6. Copy (H + uncompressed_j - lower_bound_j) modulo 2^16 to the
memory address specified by the destination operand.
<span class="h4"><a class="selflink" id="section-9.4.5" href="#section-9.4.5">9.4.5</a>. STATE-ACCESS</span>
The STATE-ACCESS instruction retrieves some previously stored state
information.
STATE-ACCESS (%partial_identifier_start, %partial_identifier_length,
%state_begin, %state_length, %state_address, %state_instruction)
The partial_identifier_start and partial_identifier_length operands
specify the location of the partial state identifier used to retrieve
the state information. This identifier has the same function as the
partial state identifier transmitted in the SigComp message as per
<a href="#section-7.2">Section 7.2</a>.
Decompression failure occurs if partial_identifier_length does not
lie between 6 and 20 inclusive. Decompression failure also occurs if
no state item matching the partial state identifier can be found, if
<span class="grey">Price, et. al. Standards Track [Page 48]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-49" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
more than one state item matches the partial identifier, or if
partial_identifier_length is less than the minimum_access_length of
the matched state item. Otherwise, a state item is returned from the
state handler.
If any of the operands state_address, state_instruction or
state_length is set to 0 then its value is taken from the returned
item of state instead.
Note that when calculating the number of UDVM cycles the STATE-ACCESS
instruction costs (1 + state_length) cycles. The value of
state_length MUST be taken from the returned item of state in the
case that the state_length operand is set to 0.
The state_begin and state_length operands define the starting byte
and number of bytes to copy from the state_value contained in the
returned item of state. Decompression failure occurs if bytes are
copied from beyond the end of the state_value. Note that
decompression failure will always occur if the state_length operand
is set to 0 but the state_begin operand is non-zero.
The state_address operand contains a UDVM memory address. The
requested portion of the state_value is byte copied to this memory
address using the rules of <a href="#section-8.4">Section 8.4</a>.
Program execution then resumes at the memory address specified by
state_instruction, unless this address is 0 in which case program
execution resumes at the next instruction following the STATE-ACCESS
instruction. Note that the latter case only occurs if both the
state_instruction operand and the state_instruction value from the
requested state are set to 0.
<span class="h4"><a class="selflink" id="section-9.4.6" href="#section-9.4.6">9.4.6</a>. STATE-CREATE</span>
The STATE-CREATE instruction requests the creation of a state item at
the receiving endpoint.
STATE-CREATE (%state_length, %state_address, %state_instruction,
%minimum_access_length, %state_retention_priority)
Note that the new state item cannot be created until a valid
compartment identifier has been returned by the application.
Consequently, when a STATE-CREATE instruction is encountered the UDVM
simply buffers the five supplied operands until the END-MESSAGE
instruction is reached. The steps taken at this point are described
in <a href="#section-9.4.9">Section 9.4.9</a>.
<span class="grey">Price, et. al. Standards Track [Page 49]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-50" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Decompression failure MUST occur if more than four state creation
requests are made before the END-MESSAGE instruction is encountered.
Decompression failure also occurs if the minimum_access_length does
not lie between 6 and 20 inclusive, or if the
state_retention_priority is 65535.
<span class="h4"><a class="selflink" id="section-9.4.7" href="#section-9.4.7">9.4.7</a>. STATE-FREE</span>
The STATE-FREE instruction informs the receiving endpoint that the
sender no longer wishes to use a particular state item.
STATE-FREE (%partial_identifier_start, %partial_identifier_length)
Note that the STATE-FREE instruction does not automatically delete a
state item, but instead reclaims the memory taken by the state item
within a certain compartment, which is generally not known before the
END-MESSAGE instruction is reached. So just as for the STATE-CREATE
instruction, when a STATE-FREE instruction is encountered the UDVM
simply buffers the two supplied operands until the END-MESSAGE
instruction is reached. The steps taken at this point are described
in <a href="#section-9.4.9">Section 9.4.9</a>.
Decompression failure MUST occur if more than four state free
requests are made before the END-MESSAGE instruction is encountered.
Decompression failure also occurs if partial_identifier_length does
not lie between 6 and 20 inclusive.
<span class="h4"><a class="selflink" id="section-9.4.8" href="#section-9.4.8">9.4.8</a>. OUTPUT</span>
The OUTPUT instruction provides successfully decompressed data to the
dispatcher.
OUTPUT (%output_start, %output_length)
The operands define the starting memory address and length of the
byte string to be provided to the dispatcher. Note that the OUTPUT
instruction can be used to output a partially decompressed message;
each time the instruction is encountered it provides a new byte
string that the dispatcher appends to the end of any bytes previously
passed to the dispatcher via the OUTPUT instruction.
The string of data is byte copied from the UDVM memory obeying the
rules of <a href="#section-8.4">Section 8.4</a>.
Decompression failure occurs if the cumulative number of bytes
provided to the dispatcher exceeds 65536 bytes.
<span class="grey">Price, et. al. Standards Track [Page 50]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-51" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Since there is technically a difference between outputting a 0-byte
decompressed message, and not outputting a decompressed message at
all, the OUTPUT instruction needs to distinguish between the two
cases. Thus, if the UDVM terminates before encountering an OUTPUT
instruction it is considered not to have outputted a decompressed
message. If it encounters one or more OUTPUT instructions, each of
which provides 0 bytes of data to the dispatcher, then it is
considered to have outputted a 0-byte decompressed message.
<span class="h4"><a class="selflink" id="section-9.4.9" href="#section-9.4.9">9.4.9</a>. END-MESSAGE</span>
The END-MESSAGE instruction successfully terminates the UDVM and
forwards the state creation and state free requests to the state
handler together with any supplied feedback data.
END-MESSAGE (%requested_feedback_location,
%returned_parameters_location, %state_length, %state_address,
%state_instruction, %minimum_access_length,
%state_retention_priority)
When the END-MESSAGE instruction is encountered, the decompressor
dispatcher indicates to the application that a complete message has
been decompressed. The application may return a compartment
identifier, which the UDVM forwards to the state handler together
with the state creation and state free requests and any supplied
feedback data.
The actual decompressed message is outputted separately using the
OUTPUT instruction; this conserves memory at the UDVM because there
is no need to buffer an entire decompressed message before it can be
passed to the dispatcher.
The END-MESSAGE instruction may pass up to four state creation
requests and up to four state free requests to the state handler.
The requests are passed to the state handler in the same order as
they are made; in particular it is possible for the state creation
requests and the state free requests to be interleaved.
The state creation requests are made by the STATE-CREATE instruction.
Note however that the END-MESSAGE can make one state creation request
itself using the supplied operands. If the specified
minimum_access_length does not lie between 6 and 20 inclusive, or if
the state_retention_priority is 65535 then the END-MESSAGE
instruction fails to make a state creation request of its own
(however decompression failure does not occur and the state creation
requests made by the STATE-CREATE instruction are still valid).
<span class="grey">Price, et. al. Standards Track [Page 51]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-52" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Note that there is a maximum limit of four state creation requests
per instance of the UDVM. Therefore, decompression failure occurs if
the END-MESSAGE instruction makes a state creation request and four
instances of the STATE-CREATE instruction have already been
encountered.
When creating a state item it is necessary to give the state_length,
state address, state_instruction and minimum_access_length; these are
supplied as operands in the STATE-CREATE instruction (or the END-
MESSAGE instruction). A complete item of state also requires a
state_value and a state_identifier, which are derived as follows:
The UDVM byte copies a string of state_length bytes from the UDVM
memory beginning at state_address (obeying the rules of <a href="#section-8.4">Section 8.4</a>).
This is the state_value.
The UDVM then calculates a 20-byte SHA-1 hash [<a href="./rfc3174" title=""US Secure Hash Algorithm 1 (SHA1)"">RFC-3174</a>] over the
byte string formed by concatenating the state_length, state_address,
state_instruction, minimum_access_length and state_value (in the
order given). This is the state_identifier.
The state_retention_priority is not part of the state item itself,
but instead determines the order in which state will be deleted when
the compartment exceeds its allocated state memory. The
state_retention_priority is supplied as an operand in the STATE-
CREATE or END-MESSAGE instruction and is passed to the state handler
as part of each state creation request.
The state free requests are made by the STATE-FREE instruction. Each
STATE-FREE instruction supplies the values partial_identifier_start
and partial_identifier_length; upon reaching the END-MESSAGE
instruction these values are used to byte copy a partial state
identifier from the UDVM memory. If no state item matching the
partial state identifier can be found or if more than one state item
in the compartment matches the partial state identifier, then the
state free request is ignored (this does not cause decompression
failure to occur). Otherwise, the state handler frees the matched
state item as specified in <a href="#section-6.2">Section 6.2</a>.
As well as forwarding the state creation and state free requests, the
END-MESSAGE instruction may also pass feedback data to the state
handler. Feedback data is used to inform the receiving endpoint
about the capabilities of the sending endpoint, which can help to
improve the overall compression ratio and to reduce the working
memory requirements of the endpoints.
<span class="grey">Price, et. al. Standards Track [Page 52]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-53" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Two types of feedback data are available: requested feedback and
returned feedback. The format of the requested feedback data is
given in Figure 12. As outlined in <a href="#section-3.2">Section 3.2</a>, the requested
feedback data can be used to influence the contents of the returned
feedback data in the reverse direction.
The returned feedback data is itself subdivided into a returned
feedback item and a list of returned SigComp parameters. The
returned feedback item is of sufficient importance to warrant its own
field in the SigComp header as described in <a href="#section-7.1">Section 7.1</a>. The
returned SigComp parameters are illustrated in Figure 13.
Note that the formats of Figure 12 and Figure 13 are only for local
presentation of the feedback data on the interface between the UDVM
and state handler. The formats do not mandate any bits on the wire;
the compressor can transmit the data in any form provided that it is
loaded into the UDVM memory at the correct addresses.
Moreover, the responsibility for ensuring that feedback data arrives
successfully over an unreliable transport lies with the sender. The
receiving endpoint always uses the last received value for each field
in the feedback data, even if the values are out of date due to
packet loss or misordering.
If the requested_feedback_location operand is set to 0, then no
feedback request is made; otherwise, it points to the starting memory
address of the requested feedback data as shown in Figure 12.
0 1 2 3 4 5 6 7
+---+---+---+---+---+---+---+---+
| reserved | Q | S | I | requested_feedback_location
+---+---+---+---+---+---+---+---+
| |
: requested feedback item : if Q = 1
| |
+---+---+---+---+---+---+---+---+
Figure 12: Format of requested feedback data
The reserved bits may be used in future versions of SigComp, and are
set to 0 in Version 0x01. Non-zero values should be ignored by the
receiving endpoint.
The Q-bit indicates whether a requested feedback item is present or
not. The compressor can set the requested feedback item to an
arbitrary value, which will then be transmitted unmodified in the
reverse direction as a returned feedback item. See Chapter 5 for
further details of how the requested feedback item is returned.
<span class="grey">Price, et. al. Standards Track [Page 53]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-54" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
The format of the requested feedback item is identical to the format
of the returned feedback item illustrated in Figure 4.
The compressor sets the S-bit to 1 if it does not wish (or no longer
wishes) to save state information at the receiving endpoint and also
does not wish to access state information that it has previously
saved. Consequently, if the S-bit is set to 1 then the receiving
endpoint can reclaim the state memory allocated to the remote
compressor and set the state_memory_size for the compartment to 0.
The compressor may change its mind and switch the S-bit back to 0 in
a later message. However, the receiving endpoint is under no
obligation to use the original state_memory_size for the compartment;
it may choose to allocate less memory to the compartment or possibly
none at all.
Similarly the compressor sets the I-bit to 1 if it does not wish (or
no longer wishes) to access any of the locally available state items
offered by the receiving endpoint. This can help to conserve
bandwidth because the list of locally available state items no longer
needs to be returned in the reverse direction. It may also conserve
memory at the receiving endpoint, as the state handler can delete any
locally available state items that it determines are no longer
required by any remote endpoint. Note that the compressor can set
the I-bit back to 0 in a later message, but it cannot access any
locally available state items that were previously offered by the
receiving endpoint unless they are subsequently re-announced.
If the returned_parameters_location operand is set to 0, then no
SigComp parameters are returned; otherwise, it points to the starting
memory address of the returned parameters as shown in Figure 13.
<span class="grey">Price, et. al. Standards Track [Page 54]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-55" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
0 1 2 3 4 5 6 7
+---+---+---+---+---+---+---+---+
| cpb | dms | sms | returned_parameters_location
+---+---+---+---+---+---+---+---+
| SigComp_version |
+---+---+---+---+---+---+---+---+
| length_of_partial_state_ID_1 |
+---+---+---+---+---+---+---+---+
| |
: partial_state_identifier_1 :
| |
+---+---+---+---+---+---+---+---+
: :
+---+---+---+---+---+---+---+---+
| length_of_partial_state_ID_n |
+---+---+---+---+---+---+---+---+
| |
: partial_state_identifier_n :
| |
+---+---+---+---+---+---+---+---+
Figure 13: Format of returned SigComp parameters
The first byte encodes the SigComp parameters cycles_per_bit,
decompression_memory_size and state_memory_size as per <a href="#section-3.3.1">Section 3.3.1</a>.
The byte can be set to 0 if the three parameters are not included in
the feedback data. (This may be useful to save bits in the
compressed message if the remote endpoint is already satisfied all
necessary information has reached the endpoint receiving the
message.)
The second byte encodes the SigComp_version as per <a href="#section-3.3.2">Section 3.3.2</a>.
Similar to the first byte, the second byte can be set to 0 if the
parameter is not included in the feedback data.
The remaining bytes encode a list of partial state identifiers for
the locally available state items offered by the sending endpoint.
Each state item is encoded as a 1-byte length field, followed by a
partial state identifier containing as many bytes as indicated in the
length field. The sender can choose to send as few as 6 bytes if it
believes that this is sufficient for the receiver to determine which
state item is being offered.
The list of state identifiers is terminated by a byte in the position
where the next length field would be expected that is set to a value
below 6 or above 20. Note that upgraded SigComp versions may append
additional items of data after the final length field.
<span class="grey">Price, et. al. Standards Track [Page 55]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-56" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h2"><a class="selflink" id="section-10" href="#section-10">10</a>. Security Considerations</span>
<span class="h3"><a class="selflink" id="section-10.1" href="#section-10.1">10.1</a>. Security Goals</span>
The overall security goal of the SigComp architecture is to not
create risks that are in addition to those already present in the
application protocols. There is no intention for SigComp to enhance
the security of the application, as it always can be circumvented by
not using compression. More specifically, the high-level security
goals can be described as:
1. Do not worsen security of existing application protocol
2. Do not create any new security issues
3. Do not hinder deployment of application security.
<span class="h3"><a class="selflink" id="section-10.2" href="#section-10.2">10.2</a>. Security Risks and Mitigation</span>
This section identifies the potential security risks associated with
SigComp, and explains how each risk is minimized by the scheme.
<span class="h4"><a class="selflink" id="section-10.2.1" href="#section-10.2.1">10.2.1</a>. Confidentiality Risks</span>
- Attacking SigComp by snooping into state of other users:
State is accessed by supplying a state identifier, which is a
cryptographic hash of the state being referenced. This implies that
the referencing message already needs knowledge about the state. To
enforce this, a state item cannot be accessed without supplying a
minimum of 48 bits from the hash. This also minimizes the
probability of an accidental state collision. A compressor can,
using the minimum_access_length operand of the STATE-CREATE and END-
MESSAGE instructions, increase the number of bits that need to be
supplied to access the state, increasing the protection against
attacks.
Generally, ways to obtain knowledge about the state identifier (e.g.,
passive attacks) will also easily provide knowledge about the
referenced state, so no new vulnerability results.
An endpoint needs to handle state identifiers with the same care it
would handle the state itself.
<span class="grey">Price, et. al. Standards Track [Page 56]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-57" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h4"><a class="selflink" id="section-10.2.2" href="#section-10.2.2">10.2.2</a>. Integrity Risks</span>
The SigComp approach assumes that there is appropriate integrity
protection below and/or above the SigComp layer. The state creation
mechanism provides some additional potential to compromise the
integrity of the messages; however, this would most likely be
detectable at the application layer.
- Attacking SigComp by faking state or making unauthorized changes to
state:
State cannot be destroyed by a malicious sender unless it can send
messages that the application identifies as belonging to the same
compartment the state was created under; this adds additional
security risks only when the application allows the installation of
SigComp state from a message where it would not have installed state
itself.
Faking or changing state is only possible if the hash allows
intentional collision.
<span class="h4"><a class="selflink" id="section-10.2.3" href="#section-10.2.3">10.2.3</a>. Availability Risks (Avoiding DoS Vulnerabilities)</span>
- Use of SigComp as a tool in a DoS attack to another target:
SigComp cannot easily be used as an amplifier in a reflection attack,
as it only generates one decompressed message per incoming compressed
message. This message is then handed to the application; the utility
as a reflection amplifier is therefore limited by the utility of the
application for this purpose.
However, it must be noted that SigComp can be used to generate larger
messages as input to the application than have to be sent from the
malicious sender; this therefore can send smaller messages (at a
lower bandwidth) than are delivered to the application. Depending on
the reflection characteristics of the application, this can be
considered a mild form of amplification. The application MUST limit
the number of packets reflected to a potential target - even if
SigComp is used to generate a large amount of information from a
small incoming attack packet.
<span class="grey">Price, et. al. Standards Track [Page 57]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-58" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
- Attacking SigComp as the DoS target by filling it with state:
Excessive state can only be installed by a malicious sender (or a set
of malicious senders) with the consent of the application. The
system consisting of SigComp and application is thus approximately as
vulnerable as the application itself, unless it allows the
installation of SigComp state from a message where it would not have
installed application state itself.
If this is desirable to increase the compression ratio, the effect
can be mitigated by making use of feedback at the application level
that indicates whether the state requested was actually installed -
this allows a system under attack to gracefully degrade by no longer
installing compressor state that is not matched by application state.
Obviously, if a stream-based transport is used, the streams
themselves constitute state that has to be handled in the same way
that the application itself would handle a stream-based transport; if
an application is not equipped for stream-based transport, it should
not allow SigComp connections on a stream-based transport. For the
alternative SigComp usage described as "continuous mode" in <a href="#section-4.2.1">Section</a>
<a href="#section-4.2.1">4.2.1</a>, an attacker could create any number of active UDVMs unless
there is some DoS protection at a lower level (e.g., by using TLS in
appropriate configurations).
- Attacking the UDVM by faking state or making unauthorized changes
to state:
This is covered in <a href="#section-10.2.2">Section 10.2.2</a>.
- Attacking the UDVM by sending it looping code:
The application sets an upper limit to the number of "UDVM cycles"
that can be used per compressed message and per input bit in the
compressed message. The damage inflicted by sending packets with
looping code is therefore limited, although this may still be
substantial if a large number of UDVM cycles are offered by the UDVM.
However, this would be true for any decompressor that can receive
packets over an unsecured transport.
<span class="h2"><a class="selflink" id="section-11" href="#section-11">11</a>. IANA Considerations</span>
SigComp requires a 1-byte name space, the SigComp_version, which has
been created by the IANA. Upgraded versions of SigComp must be
backwards-compatible with Version 0x01, described in this document.
Adding additional UDVM instructions and assigning values to the
reserved UDVM memory addresses are two possible upgrades for which
this is the case.
<span class="grey">Price, et. al. Standards Track [Page 58]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-59" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Following the policies outlined in [<a href="./rfc2434" title="">RFC-2434</a>], the IANA policy for
assigning a new value for the SigComp_version shall require a
Standards Action. Values are thus assigned only for Standards Track
RFCs approved by the IESG.
<span class="h2"><a class="selflink" id="section-12" href="#section-12">12</a>. Acknowledgements</span>
Thanks to
Abigail Surtees
Mark A West
Lawrence Conroy
Christian Schmidt
Max Riegel
Lars-Erik Jonsson
Stefan Forsgren
Krister Svanbro
Miguel Garcia
Christopher Clanton
Khiem Le
Ka Cheong Leung
Robert Sugar
for valuable input and review.
<span class="h2"><a class="selflink" id="section-13" href="#section-13">13</a>. References</span>
<span class="h3"><a class="selflink" id="section-13.1" href="#section-13.1">13.1</a>. Normative References</span>
[<a id="ref-RFC-1662">RFC-1662</a>] Simpson, W., "PPP in HDLC-like Framing", STD 51, <a href="./rfc1662">RFC</a>
<a href="./rfc1662">1662</a>, July 1994.
[<a id="ref-RFC-2119">RFC-2119</a>] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", <a href="https://www.rfc-editor.org/bcp/bcp14">BCP 14</a>, <a href="./rfc2119">RFC 2119</a>, March 1997.
[<a id="ref-RFC-3174">RFC-3174</a>] Eastlake, 3rd, D. and P. Jones, "US Secure Hash Algorithm
1 (SHA1)", <a href="./rfc3174">RFC 3174</a>, September 2001.
<span class="h3"><a class="selflink" id="section-13.2" href="#section-13.2">13.2</a>. Informative References</span>
[<a id="ref-RFC-1951">RFC-1951</a>] Deutsch, P., "DEFLATE Compressed Data Format
Specification version 1.3", <a href="./rfc1951">RFC 1951</a>, May 1996.
[<a id="ref-RFC-2026">RFC-2026</a>] Bradner, S., "The Internet Standards Process - Revision
3", <a href="https://www.rfc-editor.org/bcp/bcp9">BCP 9</a>, <a href="./rfc2026">RFC 2026</a>, October 1996.
[<a id="ref-RFC-2279">RFC-2279</a>] Yergeau, F., "UTF-8, a transformation format of ISO
10646", <a href="./rfc2279">RFC 2279</a>, January 1998.
<span class="grey">Price, et. al. Standards Track [Page 59]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-60" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
[<a id="ref-RFC-2326">RFC-2326</a>] Schulzrinne, H., Rao, A. and R. Lanphier, "Real Time
Streaming Protocol (RTSP)", <a href="./rfc2326">RFC 2326</a>, April 1998.
[<a id="ref-RFC-2434">RFC-2434</a>] Alvestrand, H. and T. Narten, "Guidelines for Writing an
IANA Considerations Section in RFCs", <a href="https://www.rfc-editor.org/bcp/bcp26">BCP 26</a>, <a href="./rfc2434">RFC 2434</a>,
October 1998.
[<a id="ref-RFC-2960">RFC-2960</a>] Stewart, R., Xie, Q., Morneault, K., Sharp, C.,
Schwartzbauer, H., Taylor, T., Rytina, I., Kalla, M.,
Zhang, L. and V. Paxson, "Stream Control Transmission
Protocol", <a href="./rfc2960">RFC 2960</a>, October 2000.
[<a id="ref-RFC-3261">RFC-3261</a>] Rosenberg, J., Schulzrinne, H., Camarillo, G., Johnston,
A., Peterson, J., Sparks, R., Handley, M. and E.
Schooler, "SIP: Session Initiation Protocol", <a href="./rfc3261">RFC 3261</a>,
June 2002.
[<a id="ref-RFC-3321">RFC-3321</a>] Hannu, H., Christoffersson, J., Forsgren, S., Leung,
K.-C., Liu, Z. and R. Price, "Signaling Compression
(SigComp) - Extended Operations", <a href="./rfc3321">RFC 3321</a>, January
2003.
<span class="h2"><a class="selflink" id="section-14" href="#section-14">14</a>. Authors' Addresses</span>
Richard Price
Roke Manor Research Ltd
Romsey, Hants, SO51 0ZN
United Kingdom
Phone: +44 1794 833681
EMail: richard.price@roke.co.uk
Carsten Bormann
Universitaet Bremen TZI
Postfach 330440
D-28334 Bremen, Germany
Phone: +49 421 218 7024
EMail: cabo@tzi.org
<span class="grey">Price, et. al. Standards Track [Page 60]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-61" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
Jan Christoffersson
Box 920
Ericsson AB
SE-971 28 Lulea, Sweden
Phone: +46 920 20 28 40
EMail: jan.christoffersson@epl.ericsson.se
Hans Hannu
Box 920
Ericsson AB
SE-971 28 Lulea, Sweden
Phone: +46 920 20 21 84
EMail: hans.hannu@epl.ericsson.se
Zhigang Liu
Nokia Research Center
6000 Connection Drive
Irving, TX 75039
Phone: +1 972 894-5935
EMail: zhigang.c.liu@nokia.com
Jonathan Rosenberg
dynamicsoft
72 Eagle Rock Avenue
First Floor
East Hanover, NJ 07936
EMail: jdrosen@dynamicsoft.com
<span class="grey">Price, et. al. Standards Track [Page 61]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-62" ></span>
<span class="grey"><a href="./rfc3320">RFC 3320</a> Signaling Compression (SigComp) January 2003</span>
<span class="h2"><a class="selflink" id="section-15" href="#section-15">15</a>. Full Copyright Statement</span>
Copyright (C) The Internet Society (2003). All Rights Reserved.
This document and translations of it may be copied and furnished to
others, and derivative works that comment on or otherwise explain it
or assist in its implementation may be prepared, copied, published
and distributed, in whole or in part, without restriction of any
kind, provided that the above copyright notice and this paragraph are
included on all such copies and derivative works. However, this
document itself may not be modified in any way, such as by removing
the copyright notice or references to the Internet Society or other
Internet organizations, except as needed for the purpose of
developing Internet standards in which case the procedures for
copyrights defined in the Internet Standards process must be
followed, or as required to translate it into languages other than
English.
The limited permissions granted above are perpetual and will not be
revoked by the Internet Society or its successors or assigns.
This document and the information contained herein is provided on an
"AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Price, et. al. Standards Track [Page 62]