1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613
|
<pre>Network Working Group B. Stewart, Editor
Request for Comments: 1318 Xyplex, Inc.
April 1992
<span class="h1">Definitions of Managed Objects</span>
<span class="h1">for Parallel-printer-like Hardware Devices</span>
Status of this Memo
This document specifies an IAB standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "IAB
Official Protocol Standards" for the standardization state and status
of this protocol. Distribution of this memo is unlimited.
<span class="h2"><a class="selflink" id="section-1" href="#section-1">1</a>. Abstract</span>
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in TCP/IP based internets.
In particular, it defines objects for the management of
parallel-printer-like devices.
<span class="h2"><a class="selflink" id="section-2" href="#section-2">2</a>. The Network Management Framework</span>
The Internet-standard Network Management Framework consists
of three components. They are:
<a href="./rfc1155">RFC 1155</a> which defines the SMI, the mechanisms used for
describing and naming objects for the purpose of management.
<a href="./rfc1212">RFC 1212</a> defines a more concise description mechanism, which
is wholly consistent with the SMI.
<a href="./rfc1156">RFC 1156</a> which defines MIB-I, the core set of managed
objects for the Internet suite of protocols. <a href="./rfc1213">RFC 1213</a>,
defines MIB-II, an evolution of MIB-I based on
implementation experience and new operational requirements.
<a href="./rfc1157">RFC 1157</a> which defines the SNMP, the protocol used for
network access to managed objects.
The Framework permits new objects to be defined for the
purpose of experimentation and evaluation.
<span class="h2"><a class="selflink" id="section-3" href="#section-3">3</a>. Objects</span>
Managed objects are accessed via a virtual information
store, termed the Management Information Base or MIB.
<span class="grey">Character MIB Working Group [Page 1]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-2" ></span>
<span class="grey"><a href="./rfc1318">RFC 1318</a> PARALLEL-PRINTER-LIKE-MIB April 1992</span>
Objects in the MIB are defined using the subset of Abstract
Syntax Notation One (ASN.1) [<a href="#ref-7" title=" International Organization for Standardization">7</a>] defined in the SMI. In
particular, each object has a name, a syntax, and an
encoding. The name is an object identifier, an
administratively assigned name, which specifies an object
type.
The object type together with an object instance serves to
uniquely identify a specific instantiation of the object.
For human convenience, we often use a textual string, termed
the OBJECT DESCRIPTOR, to also refer to the object type.
The syntax of an object type defines the abstract data
structure corresponding to that object type. The ASN.1
language is used for this purpose. However, the SMI [<a href="#ref-3" title=""Structure and Identification of Management Information for TCP/IP-based internets"">3</a>]
purposely restricts the ASN.1 constructs which may be used.
These restrictions are explicitly made for simplicity.
The encoding of an object type is simply how that object
type is represented using the object type's syntax.
Implicitly tied to the notion of an object type's syntax and
encoding is how the object type is represented when being
transmitted on the network.
The SMI specifies the use of the basic encoding rules of
ASN.1 [<a href="#ref-8" title=" International Standard 8825">8</a>], subject to the additional requirements imposed by
the SNMP.
<span class="h3"><a class="selflink" id="section-3.1" href="#section-3.1">3.1</a>. Format of Definitions</span>
<a href="#section-5">Section 5</a> contains the specification of all object types
contained in this MIB module. The object types are defined
using the conventions defined in the SMI, as amended by the
extensions specified in [<a href="#ref-9" title=""Concise MIB Definitions"">9</a>,<a href="#ref-10" title=""A Convention for Defining Traps for use with the SNMP"">10</a>].
<span class="h2"><a class="selflink" id="section-4" href="#section-4">4</a>. Overview</span>
The Parallel-printer-like Hardware Device MIB applies to
interface ports that might logically support the Interface
MIB, a Transmission MIB, or the Character MIB (most likely
the latter). The most common example is a Centronics or
Data Products type parallel printer port.
The Parallel-printer-like MIB is one of a set of MIBs
designed for complementary use. At this writing, the set
comprises:
<span class="grey">Character MIB Working Group [Page 2]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-3" ></span>
<span class="grey"><a href="./rfc1318">RFC 1318</a> PARALLEL-PRINTER-LIKE-MIB April 1992</span>
Character MIB
PPP MIB
RS-232-like MIB
Parallel-printer-like MIB
The RS-232-like MIB and the Parallel-printer-like MIB
represent the physical layer, providing service to higher
layers such as the Character MIB or PPP MIB. Further MIBs
may appear above these.
The following diagram shows two possible "MIB stacks", each
using the RS-232-like MIB.
.-----------------.
.-----------------. | Standard MIB |
| Telnet MIB | | Interface Group |
|-----------------| |-----------------|
| Character MIB | | PPP MIB |
|-----------------| |-----------------|
| RS-232-like MIB | | RS-232-like MIB |
`-----------------' `-----------------'
The intent of the model is for the physical-level MIBs to
represent the lowest level, regardless of the higher level
that may be using it. In turn, separate higher level MIBs
represent specific applications, such as a terminal (the
Character MIB) or a network connection (the PPP MIB).
The Parallel-printer-like MIB is mandatory for all systems
that have such a hardware port supporting services managed
through some other MIB, for example, the Character MIB.
The Parallel-printer-like MIB includes multiple similar
types of hardware, and as a result contains objects not
applicable to all of those types. Such objects are in a
separate branch of the MIB, which is required when
applicable and otherwise absent.
The Parallel-printer-like MIB includes Centronics, Data
Products, and other parallel physical links with a similar
set of control signals.
The MIB contains objects that relate to physical layer
connections. Such connections may provide interesting
hardware signals (other than for basic data transfer), such
as Power and PaperOut.
The MIB comprises one base object and three tables, detailed
<span class="grey">Character MIB Working Group [Page 3]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-4" ></span>
<span class="grey"><a href="./rfc1318">RFC 1318</a> PARALLEL-PRINTER-LIKE-MIB April 1992</span>
in the following sections. The tables contain objects for
ports and input and output control signals.
<span class="h2"><a class="selflink" id="section-5" href="#section-5">5</a>. Definitions</span>
<a href="./rfc1318">RFC1318</a>-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter
FROM <a href="./rfc1155">RFC1155</a>-SMI
transmission
FROM <a href="./rfc1213">RFC1213</a>-MIB
OBJECT-TYPE
FROM <a href="./rfc1212">RFC-1212</a>;
-- this is the MIB module for Parallel-printer-like
-- hardware devices
para OBJECT IDENTIFIER ::= { transmission 34 }
-- the generic Parallel-printer-like group
-- Implementation of this group is mandatory for all
-- systems that have Parallel-printer-like hardware
-- ports supporting higher level services such as
-- character streams
paraNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports (regardless of their current
state) in the Parallel-printer-like port table."
::= { para 1 }
-- the Parallel-printer-like Port table
paraPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParaPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of port entries. The number of entries is
given by the value of paraNumber."
::= { para 2 }
<span class="grey">Character MIB Working Group [Page 4]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-5" ></span>
<span class="grey"><a href="./rfc1318">RFC 1318</a> PARALLEL-PRINTER-LIKE-MIB April 1992</span>
paraPortEntry OBJECT-TYPE
SYNTAX ParaPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status and parameter values for a port."
INDEX { paraPortIndex }
::= { paraPortTable 1 }
ParaPortEntry ::=
SEQUENCE {
paraPortIndex
INTEGER,
paraPortType
INTEGER,
paraPortInSigNumber
INTEGER,
paraPortOutSigNumber
INTEGER
}
paraPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each port. Its value ranges
between 1 and the value of paraNumber. By
convention and if possible, hardware port numbers
map directly to external connectors. The value for
each port must remain constant at least from one
re-initialization of the network management agent to
the next."
::= { paraPortEntry 1 }
paraPortType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
centronics(2),
dataproducts(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port's hardware type."
::= { paraPortEntry 2 }
paraPortInSigNumber OBJECT-TYPE
<span class="grey">Character MIB Working Group [Page 5]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-6" ></span>
<span class="grey"><a href="./rfc1318">RFC 1318</a> PARALLEL-PRINTER-LIKE-MIB April 1992</span>
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of input signals for the port in the
input signal table (paraPortInSigTable). The table
contains entries only for those signals the software
can detect."
::= { paraPortEntry 3 }
paraPortOutSigNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of output signals for the port in the
output signal table (paraPortOutSigTable). The
table contains entries only for those signals the
software can assert."
::= { paraPortEntry 4 }
-- the Input Signal table
paraInSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParaInSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of port input control signal entries."
::= { para 3 }
paraInSigEntry OBJECT-TYPE
SYNTAX ParaInSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Input control signal status for a hardware port."
INDEX { paraInSigPortIndex, paraInSigName }
::= { paraInSigTable 1 }
ParaInSigEntry ::=
SEQUENCE {
paraInSigPortIndex
INTEGER,
paraInSigName
INTEGER,
paraInSigState
<span class="grey">Character MIB Working Group [Page 6]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-7" ></span>
<span class="grey"><a href="./rfc1318">RFC 1318</a> PARALLEL-PRINTER-LIKE-MIB April 1992</span>
INTEGER,
paraInSigChanges
Counter
}
paraInSigPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of paraPortIndex for the port to which
this entry belongs."
::= { paraInSigEntry 1 }
paraInSigName OBJECT-TYPE
SYNTAX INTEGER { power(1), online(2), busy(3),
paperout(4), fault(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identification of a hardware signal."
::= { paraInSigEntry 2 }
paraInSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current signal state."
::= { paraInSigEntry 3 }
paraInSigChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { paraInSigEntry 4 }
-- the Output Signal table
paraOutSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParaOutSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
<span class="grey">Character MIB Working Group [Page 7]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-8" ></span>
<span class="grey"><a href="./rfc1318">RFC 1318</a> PARALLEL-PRINTER-LIKE-MIB April 1992</span>
"A list of port output control signal entries."
::= { para 4 }
paraOutSigEntry OBJECT-TYPE
SYNTAX ParaOutSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Output control signal status for a hardware port."
INDEX { paraOutSigPortIndex, paraOutSigName }
::= { paraOutSigTable 1 }
ParaOutSigEntry ::=
SEQUENCE {
paraOutSigPortIndex
INTEGER,
paraOutSigName
INTEGER,
paraOutSigState
INTEGER,
paraOutSigChanges
Counter
}
paraOutSigPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of paraPortIndex for the port to which
this entry belongs."
::= { paraOutSigEntry 1 }
paraOutSigName OBJECT-TYPE
SYNTAX INTEGER { power(1), online(2), busy(3),
paperout(4), fault(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identification of a hardware signal."
::= { paraOutSigEntry 2 }
paraOutSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current signal state."
<span class="grey">Character MIB Working Group [Page 8]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-9" ></span>
<span class="grey"><a href="./rfc1318">RFC 1318</a> PARALLEL-PRINTER-LIKE-MIB April 1992</span>
::= { paraOutSigEntry 3 }
paraOutSigChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { paraOutSigEntry 4 }
END
<span class="h2"><a class="selflink" id="section-6" href="#section-6">6</a>. Acknowledgements</span>
Based on several private MIBs, this document was produced by the
Character MIB Working Group:
Anne Ambler, Spider
Charles Bazaar, Emulex
Christopher Bucci, Datability
Anthony Chung, Hughes LAN Systems
George Conant, Xyplex
John Cook, Chipcom
James Davin, MIT-LCS
Shawn Gallagher, DEC
Tom Grant, Xylogics
Frank Huang, Emulex
David Jordan, Emulex
Satish Joshi, SynOptics
Frank Kastenholz, Clearpoint
Ken Key, University of Tennessee
Jim Kinder, Fibercom
Rajeev Kochhar, 3Com
John LoVerso, Xylogics
Keith McCloghrie, Hughes LAN Systems
Donald Merritt, BRL
David Perkins, 3Com
Jim Reinstedler, Ungerman-Bass
Marshall Rose, PSI
Ron Strich, SSDS
Dean Throop, DG
Bill Townsend, Xylogics
Jesse Walker, DEC
David Waitzman, BBN
Bill Westfield, cisco
<span class="grey">Character MIB Working Group [Page 9]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-10" ></span>
<span class="grey"><a href="./rfc1318">RFC 1318</a> PARALLEL-PRINTER-LIKE-MIB April 1992</span>
<span class="h2"><a class="selflink" id="section-7" href="#section-7">7</a>. References</span>
[<a id="ref-1">1</a>] Cerf, V., "IAB Recommendations for the Development of Internet
Network Management Standards", <a href="./rfc1052">RFC 1052</a>, NRI, April 1988.
[<a id="ref-2">2</a>] Cerf, V., "Report of the Second Ad Hoc Network Management Review
Group", <a href="./rfc1109">RFC 1109</a>, NRI, August 1989.
[<a id="ref-3">3</a>] Rose M., and K. McCloghrie, "Structure and Identification of
Management Information for TCP/IP-based internets", <a href="./rfc1155">RFC 1155</a>,
Performance Systems International, Hughes LAN Systems, May 1990.
[<a id="ref-4">4</a>] McCloghrie K., and M. Rose, "Management Information Base for
Network Management of TCP/IP-based internets", <a href="./rfc1156">RFC 1156</a>, Hughes
LAN Systems, Performance Systems International, May 1990.
[<a id="ref-5">5</a>] Case, J., Fedor, M., Schoffstall, M., and J. Davin, Simple
Network Management Protocol", <a href="./rfc1157">RFC 1157</a>, SNMP Research,
Performance Systems International, Performance Systems
International, MIT Laboratory for Computer Science, May 1990.
[<a id="ref-6">6</a>] McCloghrie K., and M. Rose, Editors, "Management Information Base
for Network Management of TCP/IP-based internets", <a href="./rfc1213">RFC 1213</a>,
Performance Systems International, March 1991.
[<a id="ref-7">7</a>] Information processing systems - Open Systems Interconnection -
Specification of Abstract Syntax Notation One (ASN.1),
International Organization for Standardization, International
Standard 8824, December 1987.
[<a id="ref-8">8</a>] Information processing systems - Open Systems Interconnection -
Specification of Basic Encoding Rules for Abstract Notation One
(ASN.1), International Organization for Standardization,
International Standard 8825, December 1987.
[<a id="ref-9">9</a>] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
<a href="./rfc1212">RFC 1212</a>, Performance Systems International, Hughes LAN Systems,
March 1991.
[<a id="ref-10">10</a>] Rose, M., Editor, "A Convention for Defining Traps for use with
the SNMP", <a href="./rfc1215">RFC 1215</a>, Performance Systems International, March
1991.
<span class="h2"><a class="selflink" id="section-8" href="#section-8">8</a>. Security Considerations</span>
Security issues are not discussed in this memo.
<span class="grey">Character MIB Working Group [Page 10]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-11" ></span>
<span class="grey"><a href="./rfc1318">RFC 1318</a> PARALLEL-PRINTER-LIKE-MIB April 1992</span>
<span class="h2"><a class="selflink" id="section-9" href="#section-9">9</a>. Author's Address</span>
Bob Stewart
Xyplex, Inc.
330 Codman Hill Road
Boxborough, MA 01719
Phone: (508) 264-9900
EMail: rlstewart@eng.xyplex.com
Character MIB Working Group [Page 11]