1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2876 2877 2878 2879 2880 2881 2882 2883 2884 2885 2886 2887 2888 2889 2890 2891 2892 2893 2894 2895 2896 2897 2898 2899 2900 2901 2902 2903 2904 2905 2906 2907 2908 2909 2910 2911 2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923 2924 2925 2926 2927 2928 2929 2930 2931 2932 2933 2934 2935 2936 2937 2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981 2982 2983 2984 2985 2986 2987 2988 2989 2990 2991 2992 2993 2994 2995 2996 2997 2998 2999 3000 3001 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3013 3014 3015 3016 3017 3018 3019 3020 3021 3022 3023 3024 3025 3026 3027 3028 3029 3030 3031 3032 3033 3034 3035 3036 3037 3038 3039 3040 3041 3042 3043 3044 3045 3046 3047 3048 3049 3050 3051 3052 3053 3054 3055 3056 3057 3058 3059 3060 3061 3062 3063 3064 3065 3066 3067 3068 3069 3070 3071 3072 3073 3074 3075 3076 3077 3078 3079 3080 3081 3082 3083 3084 3085 3086 3087 3088 3089 3090 3091 3092 3093 3094 3095 3096 3097 3098 3099 3100 3101 3102 3103 3104 3105 3106 3107 3108 3109 3110 3111 3112 3113 3114 3115 3116 3117 3118 3119 3120 3121 3122 3123 3124 3125 3126 3127 3128 3129 3130 3131 3132 3133 3134 3135 3136 3137 3138 3139 3140 3141 3142 3143 3144 3145 3146 3147 3148 3149 3150 3151 3152 3153 3154 3155 3156 3157 3158 3159 3160 3161 3162 3163 3164 3165 3166 3167 3168 3169 3170 3171 3172 3173 3174 3175 3176 3177 3178 3179 3180 3181 3182 3183 3184 3185 3186 3187 3188 3189 3190 3191 3192 3193 3194 3195 3196 3197 3198 3199 3200 3201 3202 3203 3204 3205 3206 3207 3208 3209 3210 3211 3212 3213 3214 3215 3216 3217 3218 3219 3220 3221 3222 3223 3224 3225 3226 3227 3228 3229 3230 3231 3232 3233 3234 3235 3236 3237 3238 3239 3240 3241 3242 3243 3244 3245 3246 3247 3248 3249 3250 3251 3252 3253 3254 3255 3256 3257 3258 3259 3260 3261 3262 3263 3264 3265 3266 3267 3268 3269 3270 3271 3272 3273 3274 3275 3276 3277 3278 3279 3280 3281 3282 3283 3284 3285 3286 3287 3288 3289 3290 3291 3292 3293 3294 3295 3296 3297 3298 3299 3300 3301 3302 3303 3304 3305 3306 3307 3308 3309 3310 3311 3312 3313 3314 3315 3316 3317 3318 3319 3320 3321 3322 3323 3324 3325 3326 3327 3328 3329 3330 3331 3332 3333 3334 3335 3336 3337 3338 3339 3340 3341 3342 3343 3344 3345 3346 3347 3348 3349 3350 3351 3352 3353 3354 3355 3356 3357 3358 3359 3360 3361 3362 3363 3364 3365 3366 3367 3368 3369 3370 3371 3372 3373 3374 3375 3376 3377 3378 3379 3380 3381 3382 3383 3384 3385 3386 3387 3388 3389 3390 3391 3392 3393 3394 3395 3396 3397 3398 3399 3400 3401 3402 3403 3404 3405 3406 3407 3408 3409 3410 3411 3412 3413 3414 3415 3416 3417 3418 3419 3420 3421 3422 3423 3424 3425 3426 3427 3428 3429 3430 3431 3432 3433 3434 3435 3436 3437 3438 3439 3440 3441 3442 3443 3444 3445 3446 3447 3448 3449 3450 3451 3452 3453 3454 3455 3456 3457 3458 3459 3460 3461 3462 3463 3464 3465 3466 3467 3468 3469 3470 3471 3472 3473 3474 3475 3476 3477 3478 3479 3480 3481 3482 3483 3484 3485 3486 3487 3488 3489 3490 3491 3492 3493 3494 3495 3496 3497 3498 3499 3500 3501 3502 3503 3504 3505 3506 3507 3508 3509 3510 3511 3512 3513 3514 3515 3516 3517 3518 3519 3520 3521 3522 3523 3524 3525 3526 3527 3528 3529 3530 3531 3532 3533 3534 3535 3536 3537 3538 3539 3540 3541 3542 3543 3544 3545 3546 3547 3548 3549 3550 3551 3552 3553 3554 3555 3556 3557 3558 3559 3560 3561 3562 3563 3564 3565 3566 3567 3568 3569 3570 3571 3572 3573 3574 3575 3576 3577 3578 3579 3580 3581 3582 3583 3584 3585 3586 3587 3588 3589 3590 3591 3592 3593 3594 3595 3596 3597 3598 3599 3600 3601 3602 3603 3604 3605 3606 3607 3608 3609 3610 3611 3612 3613 3614 3615 3616 3617 3618 3619 3620 3621 3622 3623 3624 3625 3626 3627 3628 3629 3630 3631 3632 3633 3634 3635 3636 3637 3638 3639 3640 3641 3642 3643 3644 3645 3646 3647 3648 3649 3650 3651 3652 3653 3654 3655 3656 3657 3658 3659 3660 3661 3662 3663 3664 3665 3666 3667 3668 3669 3670 3671 3672 3673 3674 3675 3676 3677 3678 3679 3680 3681 3682 3683 3684 3685 3686 3687 3688 3689 3690 3691 3692 3693 3694 3695 3696 3697 3698 3699 3700 3701 3702 3703 3704 3705 3706 3707 3708 3709 3710 3711 3712 3713 3714 3715 3716 3717 3718 3719 3720 3721 3722 3723 3724 3725 3726 3727 3728 3729 3730 3731 3732 3733 3734 3735 3736 3737 3738 3739 3740 3741 3742 3743 3744 3745 3746 3747 3748 3749 3750 3751 3752 3753 3754 3755 3756 3757 3758 3759 3760 3761 3762 3763 3764 3765 3766 3767 3768 3769 3770 3771 3772 3773 3774 3775 3776 3777 3778 3779 3780 3781 3782 3783 3784 3785 3786 3787 3788 3789 3790 3791 3792 3793 3794 3795 3796 3797 3798 3799 3800 3801 3802 3803 3804 3805 3806 3807 3808 3809 3810 3811 3812 3813 3814 3815 3816 3817 3818 3819 3820 3821 3822 3823 3824 3825 3826 3827 3828 3829 3830 3831 3832 3833 3834 3835 3836 3837 3838 3839 3840 3841 3842 3843 3844 3845 3846 3847 3848 3849 3850 3851 3852 3853 3854 3855 3856 3857 3858 3859 3860 3861 3862 3863 3864 3865 3866 3867 3868 3869 3870 3871 3872 3873 3874 3875 3876 3877 3878 3879 3880 3881 3882 3883 3884 3885 3886 3887 3888 3889 3890 3891 3892 3893 3894 3895 3896 3897 3898 3899 3900 3901 3902 3903 3904 3905 3906 3907 3908 3909 3910 3911 3912 3913 3914 3915 3916 3917 3918 3919 3920 3921 3922 3923 3924 3925 3926 3927 3928 3929 3930 3931 3932 3933 3934 3935 3936 3937 3938 3939 3940 3941 3942 3943 3944 3945 3946 3947 3948 3949 3950 3951 3952 3953 3954 3955 3956 3957 3958 3959 3960 3961 3962 3963 3964 3965 3966 3967 3968 3969 3970 3971 3972 3973 3974 3975 3976 3977 3978 3979 3980 3981 3982 3983 3984 3985 3986 3987 3988 3989 3990 3991 3992 3993 3994 3995 3996 3997 3998 3999 4000 4001 4002 4003 4004 4005 4006 4007 4008 4009 4010 4011 4012 4013 4014 4015 4016 4017 4018 4019 4020 4021 4022 4023 4024 4025 4026 4027 4028 4029 4030 4031 4032 4033 4034 4035 4036 4037 4038 4039 4040 4041 4042 4043 4044 4045 4046 4047 4048 4049 4050 4051 4052 4053 4054 4055 4056 4057 4058 4059 4060 4061 4062 4063 4064 4065 4066 4067 4068 4069 4070 4071 4072 4073 4074 4075 4076 4077 4078 4079 4080 4081 4082 4083 4084 4085 4086 4087 4088 4089 4090 4091 4092 4093 4094 4095 4096 4097 4098 4099 4100 4101 4102 4103 4104 4105 4106 4107 4108 4109 4110 4111 4112 4113 4114 4115 4116 4117 4118 4119 4120 4121 4122 4123 4124 4125 4126 4127 4128 4129 4130 4131 4132 4133 4134 4135 4136 4137 4138 4139 4140 4141 4142 4143 4144 4145 4146 4147 4148 4149 4150 4151 4152 4153 4154 4155 4156 4157 4158 4159 4160 4161 4162 4163 4164 4165 4166 4167 4168 4169 4170 4171 4172 4173 4174 4175 4176 4177 4178 4179 4180 4181 4182 4183 4184 4185 4186 4187 4188 4189 4190 4191 4192 4193 4194 4195 4196 4197 4198 4199 4200 4201 4202 4203 4204 4205 4206 4207 4208 4209 4210 4211 4212 4213 4214 4215 4216 4217 4218 4219 4220 4221 4222 4223 4224 4225 4226 4227 4228 4229 4230 4231 4232 4233 4234 4235 4236 4237 4238 4239 4240 4241 4242 4243 4244 4245 4246 4247 4248 4249 4250 4251 4252 4253 4254 4255 4256 4257 4258 4259 4260 4261 4262 4263 4264 4265 4266 4267 4268 4269 4270 4271 4272 4273 4274 4275 4276 4277 4278 4279 4280 4281 4282 4283 4284 4285 4286 4287 4288 4289 4290 4291 4292 4293 4294 4295 4296 4297 4298 4299 4300 4301 4302 4303 4304 4305 4306 4307 4308 4309 4310 4311 4312 4313 4314 4315 4316 4317 4318 4319 4320 4321 4322 4323 4324 4325 4326 4327 4328 4329 4330 4331 4332 4333 4334 4335 4336 4337 4338 4339 4340 4341 4342 4343 4344 4345 4346 4347 4348 4349 4350 4351 4352 4353 4354 4355 4356 4357 4358 4359 4360 4361 4362 4363 4364 4365 4366 4367 4368 4369 4370 4371 4372 4373 4374 4375 4376 4377 4378 4379 4380 4381 4382 4383 4384 4385 4386 4387 4388 4389 4390 4391 4392 4393 4394 4395 4396 4397 4398 4399 4400 4401 4402 4403 4404 4405 4406 4407 4408 4409 4410 4411 4412 4413 4414 4415 4416 4417 4418 4419 4420 4421 4422 4423 4424 4425 4426 4427 4428 4429 4430 4431 4432 4433 4434 4435 4436 4437 4438 4439 4440 4441 4442 4443 4444 4445 4446 4447 4448 4449 4450 4451 4452 4453 4454 4455 4456 4457 4458 4459 4460 4461 4462 4463 4464 4465 4466 4467 4468 4469 4470 4471 4472 4473 4474 4475 4476 4477 4478 4479 4480 4481 4482 4483 4484 4485 4486 4487 4488 4489 4490 4491 4492 4493 4494 4495 4496 4497 4498 4499 4500 4501 4502 4503 4504 4505 4506 4507 4508 4509 4510 4511 4512 4513 4514 4515 4516 4517 4518 4519 4520 4521 4522 4523 4524 4525 4526 4527 4528 4529 4530 4531 4532 4533 4534 4535 4536 4537 4538 4539 4540 4541 4542 4543 4544 4545 4546 4547 4548 4549 4550 4551 4552 4553 4554 4555 4556 4557 4558 4559 4560 4561 4562 4563 4564 4565 4566 4567 4568 4569 4570 4571 4572 4573 4574 4575 4576 4577 4578 4579 4580 4581 4582 4583 4584 4585 4586 4587 4588 4589
|
<pre>Network Working Group K. de Graaf
Request for Comments: 2108 3Com Corporation
Obsoletes: <a href="./rfc1516">1516</a> D. Romascanu
Category: Standards Track Madge Networks (Israel) Ltd.
D. McMaster
Coloma Communications
K. McCloghrie
Cisco Systems Inc.
February 1997
<span class="h1">Definitions of Managed Objects</span>
<span class="h1">for IEEE 802.3 Repeater Devices</span>
<span class="h1">using SMIv2</span>
Status of this Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Abstract
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in the Internet community.
In particular, it defines objects for managing IEEE 802.3 10 and 100
Mb/second baseband repeaters based on IEEE Std 802.3 <a href="#section-30">Section 30</a>, "10
& 100 Mb/s Management," October 26, 1995.
Table of Contents
<a href="#section-1">1</a>. The SNMP Network Management Framework.................... <a href="#page-2">2</a>
<a href="#section-1.1">1.1</a>. Object Definitions..................................... <a href="#page-2">2</a>
<a href="#section-2">2</a>. Overview................................................. <a href="#page-2">2</a>
<a href="#section-2.1">2.1</a>. Relationship to <a href="./rfc1516">RFC 1516</a>............................... <a href="#page-2">2</a>
<a href="#section-2.2">2.2</a>. Repeater Management.................................... <a href="#page-3">3</a>
<a href="#section-2.3">2.3</a>. Structure of the MIB................................... <a href="#page-4">4</a>
<a href="#section-2.3.1">2.3.1</a>. Basic Definitions.................................... <a href="#page-4">4</a>
<a href="#section-2.3.2">2.3.2</a>. Monitor Definitions.................................. <a href="#page-4">4</a>
<a href="#section-2.3.3">2.3.3</a>. Address Tracking Definitions......................... <a href="#page-4">4</a>
<a href="#section-2.3.4">2.3.4</a>. Top N Definitions.................................... <a href="#page-4">4</a>
<a href="#section-2.4">2.4</a>. Relationship to Other MIBs............................. <a href="#page-4">4</a>
<a href="#section-2.4.1">2.4.1</a>. Relationship to MIB-II............................... <a href="#page-4">4</a>
<a href="#section-2.4.1.1">2.4.1.1</a>. Relationship to the 'system' group................. <a href="#page-5">5</a>
<a href="#section-2.4.1.2">2.4.1.2</a>. Relationship to the 'interfaces' group............. <a href="#page-5">5</a>
<a href="#section-3">3</a>. Definitions............................................... <a href="#page-6">6</a>
<span class="grey">de Graaf, et. al. Standards Track [Page 1]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-2" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
<a href="#section-4">4</a>. Topology Mapping......................................... <a href="#page-75">75</a>
<a href="#section-5">5</a>. Acknowledgements......................................... <a href="#page-79">79</a>
<a href="#section-6">6</a>. References............................................... <a href="#page-80">80</a>
<a href="#section-7">7</a>. Security Considerations.................................. <a href="#page-81">81</a>
<a href="#section-8">8</a>. Authors' Addresses....................................... <a href="#page-81">81</a>
<span class="h2"><a class="selflink" id="section-1" href="#section-1">1</a>. The SNMP Network Management Framework</span>
The SNMP Network Management Framework presently consists of three
major components. They are:
o the SMI, described in <a href="./rfc1902">RFC 1902</a> [<a href="#ref-6" title=""Structure of Management Information for version 2 of the Simple Network Management Protocol (SNMPv2)"">6</a>] - the mechanisms used
for describing and naming objects for the purpose of
management.
o the MIB-II, STD 17, <a href="./rfc1213">RFC 1213</a> [<a href="#ref-5" title=""Management Information Base for Network Management of TCP/IP-based internets: MIB-II"">5</a>] - the core set of
managed objects for the Internet suite of protocols.
o the protocol, STD 15, <a href="./rfc1157">RFC 1157</a> [<a href="#ref-10" title=""Simple Network Management Protocol"">10</a>] and/or <a href="./rfc1905">RFC 1905</a>
[<a href="#ref-9" title=""Protocol Operations for version 2 of the Simple Network Management Protocol (SNMPv2)"">9</a>] - the protocol used for accessing managed information.
Textual conventions are defined in <a href="./rfc1903">RFC 1903</a> [<a href="#ref-7" title=""Textual Conventions for version 2 of the Simple Network Management Protocol (SNMPv2)"">7</a>], and conformance
statements are defined in <a href="./rfc1904">RFC 1904</a> [<a href="#ref-8" title=""Conformance Statements for version 2 of the Simple Network Management Protocol (SNMPv2)"">8</a>].
The Framework permits new objects to be defined for the purpose of
experimentation and evaluation.
<span class="h3"><a class="selflink" id="section-1.1" href="#section-1.1">1.1</a>. Object Definitions</span>
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. Objects in the MIB are
defined using the subset of Abstract Syntax Notation one (ASN.1)
defined in the SMI. In particular, each object type is named by an
OBJECT IDENTIFIER, an administratively assigned name. The object
type together with an object instance serves to uniquely identify a
specific instantiation of the object. For human convenience, we
often use a textual string, termed the descriptor, to refer to the
object type.
<span class="h2"><a class="selflink" id="section-2" href="#section-2">2</a>. Overview</span>
<span class="h3"><a class="selflink" id="section-2.1" href="#section-2.1">2.1</a>. Relationship to <a href="./rfc1516">RFC 1516</a></span>
This MIB is intended as a superset of that defined by <a href="./rfc1516">RFC 1516</a> [<a href="#ref-11" title=""Definitions of Managed Objects for IEEE 802.3 Repeater Devices"">11</a>],
which will go to historic status. This MIB includes all of the
objects contained in that MIB, plus several new ones which provide
<span class="grey">de Graaf, et. al. Standards Track [Page 2]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-3" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
for significant additional capabilities. Implementors are encouraged
to support all applicable conformance groups in order to make the
best use of the new functionality provided by this MIB. The new
objects provide support for:
o multiple repeaters
o 100BASE-T management
o port TopN capability
o address search and topology mapping
Certain objects have been deprecated; in particular, those scalar
objects used for managing a single repeater are now of minimal use
since they are duplicated in the new multiple- repeater definitions.
Additional objects have been deprecated based on implementation
experience with <a href="./rfc1516">RFC 1516</a>.
<span class="h3"><a class="selflink" id="section-2.2" href="#section-2.2">2.2</a>. Repeater Management</span>
Instances of the object types defined in this memo represent
attributes of an IEEE 802.3 (Ethernet-like) repeater, as defined by
<a href="#section-9">Section 9</a>, "Repeater Unit for 10 Mb/s Baseband Networks" in the IEEE
802.3/ISO 8802-3 CSMA/CD standard [<a href="#ref-1">1</a>], and <a href="#section-27">Section 27</a>, "Repeater for
100 Mb/s Baseband Networks" in the IEEE Standard 802.3u-1995 [<a href="#ref-2" title=""MAC Parameters, Physical Layer, Medium Attachment Units and Repeater for 100 Mb/s Operation, Type 100BASE-T,"">2</a>].
These Repeater MIB objects may be used to manage non-standard
repeater-like devices, but defining objects to describe
implementation-specific properties of non-standard repeater- like
devices is outside the scope of this memo.
The definitions presented here are based on <a href="#section-30.4">Section 30.4</a>, "Layer
Management for 10 and 100 Mb/s Baseband Repeaters" and Annex 30A,
"GDMO Specificataions for 802.3 managed objects" of [<a href="#ref-3" title=""10 & 100 Mb/s Management,"">3</a>].
Implementors of these MIB objects should note that [<a href="#ref-3" title=""10 & 100 Mb/s Management,"">3</a>] explicitly
describes when, where, and how various repeater attributes are
measured. The IEEE document also describes the effects of repeater
actions that may be invoked by manipulating instances of the MIB
objects defined here.
The counters in this document are defined to be the same as those
counters in [<a href="#ref-3" title=""10 & 100 Mb/s Management,"">3</a>], with the intention that the same instrumentation can
be used to implement both the IEEE and IETF management standards.
<span class="grey">de Graaf, et. al. Standards Track [Page 3]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-4" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
<span class="h3"><a class="selflink" id="section-2.3" href="#section-2.3">2.3</a>. Structure of the MIB</span>
Objects in this MIB are arranged into packages, each of which
contains a set of related objects within a broad functional category.
Objects within a package are generally defined under the same OID
subtree. These packages are intended for organizational convenience
ONLY, and have no relation to the conformance groups defined later in
the document.
<span class="h4"><a class="selflink" id="section-2.3.1" href="#section-2.3.1">2.3.1</a>. Basic Definitions</span>
The basic definitions include objects which are applicable to all
repeaters: status, parameter and control objects for each repeater
within the managed system, for the port groups within the system, and
for the individual ports themselves.
<span class="h4"><a class="selflink" id="section-2.3.2" href="#section-2.3.2">2.3.2</a>. Monitor Definitions</span>
The monitor definitions include monitoring statistics for each
repeater within the system and for individual ports.
<span class="h4"><a class="selflink" id="section-2.3.3" href="#section-2.3.3">2.3.3</a>. Address Tracking Definitions</span>
This collection includes objects for tracking the MAC addresses of
the DTEs attached to the ports within the system and for mapping the
topology of a network.
Note: These definitions are based on a technology which has been
patented by Hewlett-Packard Company. HP has granted rights to this
technology to implementors of this MIB. See [<a href="#ref-12" title=""Conditional Grant of Rights to Specific Hewlett-Packard Patents In Conjunction With the Internet Engineering Task Force's Internet-Standard Network Management Framework"">12</a>] and [<a href="#ref-13" title="293">13</a>] for
details.
<span class="h4"><a class="selflink" id="section-2.3.4" href="#section-2.3.4">2.3.4</a>. Top N Definitions</span>
These objects may be used for tracking the ports with the most
activity within the system or within particular repeaters.
<span class="h3"><a class="selflink" id="section-2.4" href="#section-2.4">2.4</a>. Relationship to Other MIBs</span>
<span class="h4"><a class="selflink" id="section-2.4.1" href="#section-2.4.1">2.4.1</a>. Relationship to MIB-II</span>
It is assumed that a repeater implementing this MIB will also
implement (at least) the 'system' group defined in MIB-II [<a href="#ref-5" title=""Management Information Base for Network Management of TCP/IP-based internets: MIB-II"">5</a>].
<span class="grey">de Graaf, et. al. Standards Track [Page 4]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-5" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
<span class="h5"><a class="selflink" id="section-2.4.1.1" href="#section-2.4.1.1">2.4.1.1</a>. Relationship to the 'system' group</span>
In MIB-II, the 'system' group is defined as being mandatory for all
systems such that each managed entity contains one instance of each
object in the 'system' group. Thus, those objects apply to the
entity even if the entity's sole functionality is management of
repeaters.
<span class="h5"><a class="selflink" id="section-2.4.1.2" href="#section-2.4.1.2">2.4.1.2</a>. Relationship to the 'interfaces' group</span>
In MIB-II, the 'interfaces' group is defined as being mandatory for
all systems and contains information on an entity's interfaces, where
each interface is thought of as being attached to a 'subnetwork'.
(Note that this term is not to be confused with 'subnet' which refers
to an addressing partitioning scheme used in the Internet suite of
protocols.)
This Repeater MIB uses the notion of ports on a repeater. The
concept of a MIB-II interface has NO specific relationship to a
repeater's port. Therefore, the 'interfaces' group applies only to
the one (or more) network interfaces on which the entity managing the
repeater sends and receives management protocol operations, and does
not apply to the repeater's ports.
This is consistent with the physical-layer nature of a repeater. A
repeater is a bitwise store-and-forward device. It recognizes
activity and bits, but does not process incoming data based on any
packet-related information (such as checksum or addresses). A
repeater has no MAC address, no MAC implementation, and does not pass
packets up to higher-level protocol entities for processing.
(When a network management entity is observing a repeater, it may
appear as though the repeater is passing packets to a higher-level
protocol entity. However, this is only a means of implementing
management, and this passing of management information is not part of
the repeater functionality.)
<span class="grey">de Graaf, et. al. Standards Track [Page 5]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-6" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
<span class="h2"><a class="selflink" id="section-3" href="#section-3">3</a>. Definitions</span>
SNMP-REPEATER-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter32, Counter64, Integer32, Gauge32, TimeTicks,
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, mib-2
FROM SNMPv2-SMI
TimeStamp, DisplayString, MacAddress, TEXTUAL-CONVENTION,
RowStatus, TestAndIncr
FROM SNMPv2-TC
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
OwnerString
FROM IF-MIB;
snmpRptrMod MODULE-IDENTITY
LAST-UPDATED "9609140000Z"
ORGANIZATION "IETF HUB MIB Working Group"
CONTACT-INFO
"WG E-mail: hubmib@hprnd.rose.hp.com
Chair: Dan Romascanu
Postal: Madge Networks (Israel) Ltd.
Atidim Technology Park, Bldg. 3
Tel Aviv 61131, Israel
Tel: 972-3-6458414, 6458458
Fax: 972-3-6487146
E-mail: dromasca@madge.com
Editor: Kathryn de Graaf
Postal: 3Com Corporation
118 Turnpike Rd.
Southborough, MA 01772 USA
Tel: (508)229-1627
Fax: (508)490-5882
E-mail: kdegraaf@isd.3com.com"
DESCRIPTION
"Management information for 802.3 repeaters.
The following references are used throughout
this MIB module:
[IEEE 802.3 Std]
refers to IEEE 802.3/ISO 8802-3 Information
processing systems - Local area networks -
Part 3: Carrier sense multiple access with
<span class="grey">de Graaf, et. al. Standards Track [Page 6]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-7" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
collision detection (CSMA/CD) access method
and physical layer specifications (1993).
[IEEE 802.3 Mgt]
refers to IEEE 802.3u-1995, '10 Mb/s &
100 Mb/s Management, <a href="#section-30">Section 30</a>,'
Supplement to ANSI/IEEE 802.3.
The following terms are used throughout this
MIB module. For complete formal definitions,
the IEEE 802.3 standards should be consulted
wherever possible:
System - A managed entity compliant with this
MIB, and incorporating at least one managed
802.3 repeater.
Chassis - An enclosure for one managed repeater,
part of a managed repeater, or several managed
repeaters. It typically contains an integral
power supply and a variable number of available
module slots.
Repeater-unit - The portion of the repeater set
that is inboard of the physical media interfaces.
The physical media interfaces (MAUs, AUIs) may be
physically separated from the repeater-unit, or
they may be integrated into the same physical
package.
Trivial repeater-unit - An isolated port that can
gather statistics.
Group - A recommended, but optional, entity
defined by the IEEE 802.3 management standard,
in order to support a modular numbering scheme.
The classical example allows an implementor to
represent field-replaceable units as groups of
ports, with the port numbering matching the
modular hardware implementation.
System interconnect segment - An internal
segment allowing interconnection of ports
belonging to different physical entities
into the same logical manageable repeater.
Examples of implementation might be
backplane busses in modular hubs, or
chaining cables in stacks of hubs.
<span class="grey">de Graaf, et. al. Standards Track [Page 7]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-8" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
Stack - A scalable system that may include
managed repeaters, in which modularity is
achieved by interconnecting a number of
different chassis.
Module - A building block in a modular
chassis. It typically maps into one 'slot';
however, the range of configurations may be
very large, with several modules entering
one slot, or one module covering several
slots.
"
REVISION "9309010000Z"
DESCRIPTION
"Published as <a href="./rfc1516">RFC 1516</a>"
REVISION "9210010000Z"
DESCRIPTION
"Published as <a href="./rfc1368">RFC 1368</a>"
::= { snmpDot3RptrMgt 5 }
snmpDot3RptrMgt OBJECT IDENTIFIER ::= { mib-2 22 }
OptMacAddr ::= TEXTUAL-CONVENTION
DISPLAY-HINT "1x:"
STATUS current
DESCRIPTION
"Either a 6 octet address in the `canonical'
order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first
if a value is available or a zero length string."
REFERENCE
"See MacAddress in SNMPv2-TC. The only difference
is that a zero length string is allowed as a value
for OptMacAddr and not for MacAddress."
SYNTAX OCTET STRING (SIZE (0 | 6))
-- Basic information at the repeater, group, and port level.
rptrBasicPackage
OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 1 }
rptrRptrInfo
OBJECT IDENTIFIER ::= { rptrBasicPackage 1 }
rptrGroupInfo
<span class="grey">de Graaf, et. al. Standards Track [Page 8]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-9" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
OBJECT IDENTIFIER ::= { rptrBasicPackage 2 }
rptrPortInfo
OBJECT IDENTIFIER ::= { rptrBasicPackage 3 }
rptrAllRptrInfo
OBJECT IDENTIFIER ::= { rptrBasicPackage 4 }
-- Monitoring information at the repeater, group, and port level.
rptrMonitorPackage
OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 2 }
rptrMonitorRptrInfo
OBJECT IDENTIFIER ::= { rptrMonitorPackage 1 }
rptrMonitorGroupInfo
OBJECT IDENTIFIER ::= { rptrMonitorPackage 2 }
rptrMonitorPortInfo
OBJECT IDENTIFIER ::= { rptrMonitorPackage 3 }
rptrMonitorAllRptrInfo
OBJECT IDENTIFIER ::= { rptrMonitorPackage 4 }
-- Address tracking information at the repeater, group,
-- and port level.
rptrAddrTrackPackage
OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 3 }
rptrAddrTrackRptrInfo
OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 1 }
rptrAddrTrackGroupInfo
-- this subtree is currently unused
OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 2 }
rptrAddrTrackPortInfo
OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 3 }
-- TopN information.
rptrTopNPackage
OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 4 }
rptrTopNRptrInfo
-- this subtree is currently unused
OBJECT IDENTIFIER ::= { rptrTopNPackage 1 }
rptrTopNGroupInfo
-- this subtree is currently unused
OBJECT IDENTIFIER ::= { rptrTopNPackage 2 }
rptrTopNPortInfo
OBJECT IDENTIFIER ::= { rptrTopNPackage 3 }
-- Old version of basic information at the repeater level.
--
-- In a system containing a single managed repeater,
-- configuration, status, and control objects for the overall
-- repeater.
<span class="grey">de Graaf, et. al. Standards Track [Page 9]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-10" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
--
-- The objects contained under the rptrRptrInfo subtree are
-- intended for backwards compatibility with implementations of
-- <a href="./rfc1516">RFC 1516</a> [<a href="#ref-11" title=""Definitions of Managed Objects for IEEE 802.3 Repeater Devices"">11</a>]. In newer implementations (both single- and
-- multiple-repeater implementations) the rptrInfoTable should
-- be implemented. It is the preferred source of this information,
-- as it contains the values for all repeaters managed by the
-- agent. In all cases, the objects in the rptrRptrInfo subtree
-- are duplicates of the corresponding objects in the first entry
-- of the rptrInfoTable.
rptrGroupCapacity OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
The rptrGroupCapacity is the number of groups
that can be contained within the repeater. Within
each managed repeater, the groups are uniquely
numbered in the range from 1 to rptrGroupCapacity.
Some groups may not be present in the repeater, in
which case the actual number of groups present
will be less than rptrGroupCapacity. The number
of groups present will never be greater than
rptrGroupCapacity.
Note: In practice, this will generally be the
number of field-replaceable units (i.e., modules,
cards, or boards) that can fit in the physical
repeater enclosure, and the group numbers will
correspond to numbers marked on the physical
enclosure."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.1.3,
aRepeaterGroupCapacity."
::= { rptrRptrInfo 1 }
rptrOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- undefined or unknown
ok(2), -- no known failures
rptrFailure(3), -- repeater-related failure
groupFailure(4), -- group-related failure
portFailure(5), -- port-related failure
generalFailure(6) -- failure, unspecified type
<span class="grey">de Graaf, et. al. Standards Track [Page 10]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-11" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
The rptrOperStatus object indicates the
operational state of the repeater. The
rptrHealthText object may be consulted for more
specific information about the state of the
repeater's health.
In the case of multiple kinds of failures (e.g.,
repeater failure and port failure), the value of
this attribute shall reflect the highest priority
failure in the following order, listed highest
priority first:
rptrFailure(3)
groupFailure(4)
portFailure(5)
generalFailure(6)."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.1.5, aRepeaterHealthState."
::= { rptrRptrInfo 2 }
rptrHealthText OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
The health text object is a text string that
provides information relevant to the operational
state of the repeater. Agents may use this string
to provide detailed information on current
failures, including how they were detected, and/or
instructions for problem resolution. The contents
are agent-specific."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.1.6, aRepeaterHealthText."
::= { rptrRptrInfo 3 }
rptrReset OBJECT-TYPE
SYNTAX INTEGER {
noReset(1),
reset(2)
<span class="grey">de Graaf, et. al. Standards Track [Page 11]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-12" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
Setting this object to reset(2) causes a
transition to the START state of Fig 9-2 in
<a href="#section-9">section 9</a> [IEEE 802.3 Std] for a 10Mb/s repeater,
and the START state of Fig 27-2 in <a href="#section-27">section 27</a>
of that standard for a 100Mb/s repeater.
Setting this object to noReset(1) has no effect.
The agent will always return the value noReset(1)
when this object is read.
After receiving a request to set this variable to
reset(2), the agent is allowed to delay the reset
for a short period. For example, the implementor
may choose to delay the reset long enough to allow
the SNMP response to be transmitted. In any
event, the SNMP response must be transmitted.
This action does not reset the management counters
defined in this document nor does it affect the
portAdminStatus parameters. Included in this
action is the execution of a disruptive Self-Test
with the following characteristics: a) The nature
of the tests is not specified. b) The test resets
the repeater but without affecting management
information about the repeater. c) The test does
not inject packets onto any segment. d) Packets
received during the test may or may not be
transferred. e) The test does not interfere with
management functions.
After performing this self-test, the agent will
update the repeater health information (including
rptrOperStatus and rptrHealthText), and send a
rptrHealth trap."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.2.1, acResetRepeater."
::= { rptrRptrInfo 4 }
rptrNonDisruptTest OBJECT-TYPE
SYNTAX INTEGER {
noSelfTest(1),
selfTest(2)
<span class="grey">de Graaf, et. al. Standards Track [Page 12]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-13" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
Setting this object to selfTest(2) causes the
repeater to perform a agent-specific, non-
disruptive self-test that has the following
characteristics: a) The nature of the tests is
not specified. b) The test does not change the
state of the repeater or management information
about the repeater. c) The test does not inject
packets onto any segment. d) The test does not
prevent the relay of any packets. e) The test
does not interfere with management functions.
After performing this test, the agent will update
the repeater health information (including
rptrOperStatus and rptrHealthText) and send a
rptrHealth trap.
Note that this definition allows returning an
'okay' result after doing a trivial test.
Setting this object to noSelfTest(1) has no
effect. The agent will always return the value
noSelfTest(1) when this object is read."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.2.2,
acExecuteNonDisruptiveSelfTest."
::= { rptrRptrInfo 5 }
rptrTotalPartitionedPorts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
This object returns the total number of ports in
the repeater whose current state meets all three
of the following criteria: rptrPortOperStatus
does not have the value notPresent(3),
rptrPortAdminStatus is enabled(1), and
rptrPortAutoPartitionState is autoPartitioned(2)."
::= { rptrRptrInfo 6 }
<span class="grey">de Graaf, et. al. Standards Track [Page 13]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-14" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
-- Basic information at the group level.
--
-- Configuration and status objects for each
-- managed group in the system, independent
-- of whether there is one or more managed
-- repeater-units in the system.
rptrGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of descriptive and status information about
the groups of ports."
::= { rptrGroupInfo 1 }
rptrGroupEntry OBJECT-TYPE
SYNTAX RptrGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing information
about a single group of ports."
INDEX { rptrGroupIndex }
::= { rptrGroupTable 1 }
RptrGroupEntry ::=
SEQUENCE {
rptrGroupIndex
Integer32,
rptrGroupDescr
DisplayString,
rptrGroupObjectID
OBJECT IDENTIFIER,
rptrGroupOperStatus
INTEGER,
rptrGroupLastOperStatusChange
TimeTicks,
rptrGroupPortCapacity
Integer32
}
rptrGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the group within the
<span class="grey">de Graaf, et. al. Standards Track [Page 14]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-15" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
system for which this entry contains
information."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.2.1.1, aGroupID."
::= { rptrGroupEntry 1 }
rptrGroupDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
A textual description of the group. This value
should include the full name and version
identification of the group's hardware type and
indicate how the group is differentiated from
other types of groups in the repeater. Plug-in
Module, Rev A' or 'Barney Rubble 10BASE-T 4-port
SIMM socket Version 2.1' are examples of valid
group descriptions.
It is mandatory that this only contain printable
ASCII characters."
::= { rptrGroupEntry 2 }
rptrGroupObjectID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor's authoritative identification of the
group. This value may be allocated within the SMI
enterprises subtree (1.3.6.1.4.1) and provides a
straight-forward and unambiguous means for
determining what kind of group is being managed.
For example, this object could take the value
1.3.6.1.4.1.4242.1.2.14 if vendor 'Flintstones,
Inc.' was assigned the subtree 1.3.6.1.4.1.4242,
and had assigned the identifier
1.3.6.1.4.1.4242.1.2.14 to its 'Wilma Flintstone
6-Port FOIRL Plug-in Module.'"
::= { rptrGroupEntry 3 }
rptrGroupOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
<span class="grey">de Graaf, et. al. Standards Track [Page 15]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-16" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
operational(2),
malfunctioning(3),
notPresent(4),
underTest(5),
resetInProgress(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An object that indicates the operational status
of the group.
A status of notPresent(4) indicates that the group
is temporarily or permanently physically and/or
logically not a part of the repeater. It is an
implementation-specific matter as to whether the
agent effectively removes notPresent entries from
the table.
A status of operational(2) indicates that the
group is functioning, and a status of
malfunctioning(3) indicates that the group is
malfunctioning in some way."
::= { rptrGroupEntry 4 }
rptrGroupLastOperStatusChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
An object that contains the value of sysUpTime at
the time when the last of the following occurred:
1) the agent cold- or warm-started;
2) the row for the group was created (such
as when the group was added to the system); or
3) the value of rptrGroupOperStatus for the
group changed.
A value of zero indicates that the group's
operational status has not changed since the agent
last restarted."
::= { rptrGroupEntry 5 }
rptrGroupPortCapacity OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
<span class="grey">de Graaf, et. al. Standards Track [Page 16]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-17" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
STATUS current
DESCRIPTION
"The rptrGroupPortCapacity is the number of ports
that can be contained within the group. Valid
range is 1-2147483647. Within each group, the
ports are uniquely numbered in the range from 1 to
rptrGroupPortCapacity.
Some ports may not be present in the system, in
which case the actual number of ports present
will be less than the value of rptrGroupPortCapacity.
The number of ports present in the group will never
be greater than the value of rptrGroupPortCapacity.
Note: In practice, this will generally be the
number of ports on a module, card, or board, and
the port numbers will correspond to numbers marked
on the physical embodiment."
REFERENCE
"IEEE 802.3 Mgt, 30.4.2.1.2, aGroupPortCapacity."
::= { rptrGroupEntry 6 }
-- Basic information at the port level.
--
-- Configuration and status objects for
-- each managed repeater port in the system,
-- independent of whether there is one or more
-- managed repeater-units in the system.
rptrPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of descriptive and status information about
the repeater ports in the system. The number of
entries is independent of the number of repeaters
in the managed system."
::= { rptrPortInfo 1 }
rptrPortEntry OBJECT-TYPE
SYNTAX RptrPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing information
about a single port."
<span class="grey">de Graaf, et. al. Standards Track [Page 17]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-18" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
INDEX { rptrPortGroupIndex, rptrPortIndex }
::= { rptrPortTable 1 }
RptrPortEntry ::=
SEQUENCE {
rptrPortGroupIndex
Integer32,
rptrPortIndex
Integer32,
rptrPortAdminStatus
INTEGER,
rptrPortAutoPartitionState
INTEGER,
rptrPortOperStatus
INTEGER,
rptrPortRptrId
Integer32
}
rptrPortGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the group containing the
port for which this entry contains information."
::= { rptrPortEntry 1 }
rptrPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the port within the group
for which this entry contains information. This
identifies the port independently from the repeater
it may be attached to. The numbering scheme for
ports is implementation specific; however, this
value can never be greater than
rptrGroupPortCapacity for the associated group."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID."
::= { rptrPortEntry 2 }
rptrPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
<span class="grey">de Graaf, et. al. Standards Track [Page 18]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-19" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to disabled(2) disables the
port. A disabled port neither transmits nor
receives. Once disabled, a port must be
explicitly enabled to restore operation. A port
which is disabled when power is lost or when a
reset is exerted shall remain disabled when normal
operation resumes.
The admin status takes precedence over auto-
partition and functionally operates between the
auto-partition mechanism and the AUI/PMA.
Setting this object to enabled(1) enables the port
and exerts a BEGIN on the port's auto-partition
state machine.
(In effect, when a port is disabled, the value of
rptrPortAutoPartitionState for that port is frozen
until the port is next enabled. When the port
becomes enabled, the rptrPortAutoPartitionState
becomes notAutoPartitioned(1), regardless of its
pre-disabling state.)"
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.2, aPortAdminState
and 30.4.3.2.1, acPortAdminControl."
::= { rptrPortEntry 3 }
rptrPortAutoPartitionState OBJECT-TYPE
SYNTAX INTEGER {
notAutoPartitioned(1),
autoPartitioned(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The autoPartitionState flag indicates whether the
port is currently partitioned by the repeater's
auto-partition protection.
The conditions that cause port partitioning are
specified in partition state machine in Sections
9 and 27 of [IEEE 802.3 Std]. They are not
differentiated here."
REFERENCE
<span class="grey">de Graaf, et. al. Standards Track [Page 19]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-20" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
"[IEEE 802.3 Mgt], 30.4.3.1.3, aAutoPartitionState."
::= { rptrPortEntry 4 }
rptrPortOperStatus OBJECT-TYPE
SYNTAX INTEGER {
operational(1),
notOperational(2),
notPresent(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the port's operational
status. The notPresent(3) status indicates the
port is physically removed (note this may or may
not be possible depending on the type of port.)
The operational(1) status indicates that the port
is enabled (see rptrPortAdminStatus) and working,
even though it might be auto-partitioned (see
rptrPortAutoPartitionState).
If this object has the value operational(1) and
rptrPortAdminStatus is set to disabled(2), it is
expected that this object's value will soon change
to notOperational(2)."
::= { rptrPortEntry 5 }
rptrPortRptrId OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the repeater to
which this port belongs. The repeater
identified by a particular value of this object
is the same as that identified by the same
value of rptrInfoId. A value of zero
indicates that this port currently is not
a member of any repeater."
::= { rptrPortEntry 6 }
-- New version of basic information at the repeater level.
--
-- Configuration, status, and control objects for
-- each managed repeater in the system.
rptrInfoTable OBJECT-TYPE
<span class="grey">de Graaf, et. al. Standards Track [Page 20]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-21" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
SYNTAX SEQUENCE OF RptrInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information about each
non-trivial repeater. The number of entries
depends on the physical configuration of the
managed system."
::= { rptrAllRptrInfo 1 }
rptrInfoEntry OBJECT-TYPE
SYNTAX RptrInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing information
about a single non-trivial repeater."
INDEX { rptrInfoId }
::= { rptrInfoTable 1 }
RptrInfoEntry ::=
SEQUENCE {
rptrInfoId
Integer32,
rptrInfoRptrType
INTEGER,
rptrInfoOperStatus
INTEGER,
rptrInfoReset
INTEGER,
rptrInfoPartitionedPorts
Gauge32,
rptrInfoLastChange
TimeStamp
}
rptrInfoId OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the repeater for which
this entry contains information."
::= { rptrInfoEntry 1 }
rptrInfoRptrType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- undefined or unknown
<span class="grey">de Graaf, et. al. Standards Track [Page 21]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-22" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
tenMb(2),
onehundredMbClassI(3),
onehundredMbClassII(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The rptrInfoRptrType returns a value that identifies
the CSMA/CD repeater type."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.1.2, aRepeaterType."
::= { rptrInfoEntry 2 }
rptrInfoOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
failure(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The rptrInfoOperStatus object indicates the
operational state of the repeater."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.1.5, aRepeaterHealthState."
::= { rptrInfoEntry 3 }
rptrInfoReset OBJECT-TYPE
SYNTAX INTEGER {
noReset(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to reset(2) causes a
transition to the START state of Fig 9-2 in
<a href="#section-9">section 9</a> [IEEE 802.3 Std] for a 10Mb/s repeater,
and to the START state of Fig 27-2 in <a href="#section-27">section 27</a>
of that standard for a 100Mb/s repeater.
Setting this object to noReset(1) has no effect.
The agent will always return the value noReset(1)
when this object is read.
After receiving a request to set this variable to
reset(2), the agent is allowed to delay the reset
<span class="grey">de Graaf, et. al. Standards Track [Page 22]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-23" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
for a short period. For example, the implementor
may choose to delay the reset long enough to allow
the SNMP response to be transmitted. In any
event, the SNMP response must be transmitted.
This action does not reset the management counters
defined in this document nor does it affect the
portAdminStatus parameters. Included in this
action is the execution of a disruptive Self-Test
with the following characteristics: a) The nature
of the tests is not specified. b) The test resets
the repeater but without affecting management
information about the repeater. c) The test does
not inject packets onto any segment. d) Packets
received during the test may or may not be
transferred. e) The test does not interfere with
management functions.
After performing this self-test, the agent will
update the repeater health information (including
rptrInfoOperStatus), and send a rptrInfoResetEvent
notification."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.2.1, acResetRepeater."
::= { rptrInfoEntry 4 }
rptrInfoPartitionedPorts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the total number of ports in
the repeater whose current state meets all three
of the following criteria: rptrPortOperStatus
does not have the value notPresent(3),
rptrPortAdminStatus is enabled(1), and
rptrPortAutoPartitionState is autoPartitioned(2)."
::= { rptrInfoEntry 5 }
rptrInfoLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when any of the following
conditions occurred:
1) agent cold- or warm-started;
2) this instance of repeater was created
<span class="grey">de Graaf, et. al. Standards Track [Page 23]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-24" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
(such as when a device or module was
added to the system);
3) a change in the value of rptrInfoOperStatus;
4) ports were added or removed as members of
the repeater; or
5) any of the counters associated with this
repeater had a discontinuity."
::= { rptrInfoEntry 6 }
--
-- Old version of statistics at the repeater level.
--
-- Performance monitoring statistics for the repeater
--
-- In a system containing a single managed repeater-unit,
-- the statistics object for the repeater-unit.
-- The objects contained under the rptrMonitorRptrInfo subtree are
-- intended for backwards compatibility with implementations of
-- <a href="./rfc1516">RFC 1516</a> [<a href="#ref-11" title=""Definitions of Managed Objects for IEEE 802.3 Repeater Devices"">11</a>]. In newer implementations (both single- and
-- multiple-repeater implementations), the rptrMonitorTable will
-- be implemented. It is the preferred source of this information,
-- as it contains the values for all repeaters managed by the
-- agent. In all cases, the objects in the rptrMonitorRptrInfo
-- subtree are duplicates of the corresponding objects in the
-- first entry of the rptrMonitorTable.
rptrMonitorTransmitCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
For a clause 9 (10Mb/s) repeater, this counter
is incremented every time the repeater state
machine enters the TRANSMIT COLLISION state
from any state other than ONE PORT LEFT
(Ref: Fig 9-2 [IEEE 802.3 Std]).
For a clause 27 repeater, this counter is
incremented every time the repeater core state
diagram enters the Jam state as a result of
Activity(ALL) > 1 (fig 27-2 [IEEE 802.3 Std]).
<span class="grey">de Graaf, et. al. Standards Track [Page 24]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-25" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
The approximate minimum time for rollover of this
counter is 16 hours in a 10Mb/s repeater and 1.6
hours in a 100Mb/s repeater."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.1.8, aTransmitCollisions."
::= { rptrMonitorRptrInfo 1 }
-- Statistics at the group level.
--
-- In a system containing a single managed repeater-unit,
-- the statistics objects for each group.
rptrMonitorGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrMonitorGroupEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
Table of performance and error statistics for the
groups within the repeater. The number of entries
is the same as that in the rptrGroupTable."
::= { rptrMonitorGroupInfo 1 }
rptrMonitorGroupEntry OBJECT-TYPE
SYNTAX RptrMonitorGroupEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
An entry in the table, containing total
performance and error statistics for a single
group. Regular retrieval of the information in
this table provides a means of tracking the
performance and health of the networked devices
attached to this group's ports.
The counters in this table are redundant in the
sense that they are the summations of information
already available through other objects. However,
these sums provide a considerable optimization of
network management traffic over the otherwise
necessary retrieval of the individual counters
included in each sum.
Note: Group-level counters are
<span class="grey">de Graaf, et. al. Standards Track [Page 25]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-26" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
deprecated in this MIB. It is recommended
that management applications instead use
the repeater-level counters contained in
the rptrMonTable."
INDEX { rptrMonitorGroupIndex }
::= { rptrMonitorGroupTable 1 }
RptrMonitorGroupEntry ::=
SEQUENCE {
rptrMonitorGroupIndex
Integer32,
rptrMonitorGroupTotalFrames
Counter32,
rptrMonitorGroupTotalOctets
Counter32,
rptrMonitorGroupTotalErrors
Counter32
}
rptrMonitorGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
This object identifies the group within the
repeater for which this entry contains
information."
::= { rptrMonitorGroupEntry 1 }
rptrMonitorGroupTotalFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
The total number of frames of valid frame length
that have been received on the ports in this group
and for which the FCSError and CollisionEvent
signals were not asserted. This counter is the
summation of the values of the
rptrMonitorPortReadableFrames counters for all of
the ports in the group.
This statistic provides one of the parameters
necessary for obtaining the packet error rate.
<span class="grey">de Graaf, et. al. Standards Track [Page 26]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-27" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
The approximate minimum time for rollover of this
counter is 80 hours in a 10Mb/s repeater."
::= { rptrMonitorGroupEntry 2 }
rptrMonitorGroupTotalOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
The total number of octets contained in the valid
frames that have been received on the ports in
this group. This counter is the summation of the
values of the rptrMonitorPortReadableOctets
counters for all of the ports in the group.
This statistic provides an indicator of the total
data transferred. The approximate minimum time
for rollover of this counter is 58 minutes in a
10Mb/s repeater."
::= { rptrMonitorGroupEntry 3 }
rptrMonitorGroupTotalErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
The total number of errors which have occurred on
all of the ports in this group. This counter is
the summation of the values of the
rptrMonitorPortTotalErrors counters for all of the
ports in the group."
::= { rptrMonitorGroupEntry 4 }
-- Statistics at the port level.
--
rptrMonitorPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrMonitorPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of performance and error statistics for the
ports. The number of entries is the same as that
<span class="grey">de Graaf, et. al. Standards Track [Page 27]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-28" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
in the rptrPortTable.
The columnar object rptrMonitorPortLastChange
is used to indicate possible discontinuities
of counter type columnar objects in the table."
::= { rptrMonitorPortInfo 1 }
rptrMonitorPortEntry OBJECT-TYPE
SYNTAX RptrMonitorPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing performance and
error statistics for a single port."
INDEX { rptrMonitorPortGroupIndex, rptrMonitorPortIndex }
::= { rptrMonitorPortTable 1 }
RptrMonitorPortEntry ::=
SEQUENCE {
rptrMonitorPortGroupIndex
Integer32,
rptrMonitorPortIndex
Integer32,
rptrMonitorPortReadableFrames
Counter32,
rptrMonitorPortReadableOctets
Counter32,
rptrMonitorPortFCSErrors
Counter32,
rptrMonitorPortAlignmentErrors
Counter32,
rptrMonitorPortFrameTooLongs
Counter32,
rptrMonitorPortShortEvents
Counter32,
rptrMonitorPortRunts
Counter32,
rptrMonitorPortCollisions
Counter32,
rptrMonitorPortLateEvents
Counter32,
rptrMonitorPortVeryLongEvents
Counter32,
rptrMonitorPortDataRateMismatches
Counter32,
rptrMonitorPortAutoPartitions
Counter32,
rptrMonitorPortTotalErrors
<span class="grey">de Graaf, et. al. Standards Track [Page 28]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-29" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
Counter32,
rptrMonitorPortLastChange
TimeStamp
}
rptrMonitorPortGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the group containing the
port for which this entry contains information."
::= { rptrMonitorPortEntry 1 }
rptrMonitorPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the port within the group
for which this entry contains information."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID."
::= { rptrMonitorPortEntry 2 }
rptrMonitorPortReadableFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the number of frames of valid
frame length that have been received on this port.
This counter is incremented by one for each frame
received on this port whose OctetCount is greater
than or equal to minFrameSize and less than or
equal to maxFrameSize (Ref: IEEE 802.3 Std,
4.4.2.1) and for which the FCSError and
CollisionEvent signals are not asserted.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
This statistic provides one of the parameters
necessary for obtaining the packet error rate.
The approximate minimum time for rollover of this
counter is 80 hours at 10Mb/s."
REFERENCE
<span class="grey">de Graaf, et. al. Standards Track [Page 29]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-30" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
"[IEEE 802.3 Mgt], 30.4.3.1.4, aReadableFrames."
::= { rptrMonitorPortEntry 3 }
rptrMonitorPortReadableOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the number of octets contained in
valid frames that have been received on this port.
This counter is incremented by OctetCount for each
frame received on this port which has been
determined to be a readable frame (i.e., including
FCS octets but excluding framing bits and dribble
bits).
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
This statistic provides an indicator of the total
data transferred. The approximate minimum time
for rollover of this counter in a 10Mb/s repeater
is 58 minutes.
For ports receiving traffic at a maximum rate in
a 100Mb/s repeater, this counter can roll over
in less than 6 minutes. Since that amount of time
could be less than a management station's poll cycle
time, in order to avoid a loss of information a
management station is advised to also poll the
rptrMonitorPortUpper32Octets object, or to use the
64-bit counter defined by
rptrMonitorPortHCReadableOctets instead of the
two 32-bit counters."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.5, aReadableOctets."
::= { rptrMonitorPortEntry 4 }
rptrMonitorPortFCSErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one for each frame
received on this port with the FCSError signal
asserted and the FramingError and CollisionEvent
signals deasserted and whose OctetCount is greater
<span class="grey">de Graaf, et. al. Standards Track [Page 30]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-31" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
than or equal to minFrameSize and less than or
equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3
Std).
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
The approximate minimum time for rollover of this
counter is 80 hours at 10Mb/s."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.6,
aFrameCheckSequenceErrors."
::= { rptrMonitorPortEntry 5 }
rptrMonitorPortAlignmentErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one for each frame
received on this port with the FCSError and
FramingError signals asserted and CollisionEvent
signal deasserted and whose OctetCount is greater
than or equal to minFrameSize and less than or
equal to maxFrameSize (Ref: IEEE 802.3 Std,
4.4.2.1). If rptrMonitorPortAlignmentErrors is
incremented then the rptrMonitorPortFCSErrors
Counter shall not be incremented for the same
frame.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
The approximate minimum time for rollover of this
counter is 80 hours at 10Mb/s."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.7, aAlignmentErrors."
::= { rptrMonitorPortEntry 6 }
rptrMonitorPortFrameTooLongs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one for each frame
received on this port whose OctetCount is greater
<span class="grey">de Graaf, et. al. Standards Track [Page 31]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-32" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std).
If rptrMonitorPortFrameTooLongs is incremented
then neither the rptrMonitorPortAlignmentErrors
nor the rptrMonitorPortFCSErrors counter shall be
incremented for the frame.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
The approximate minimum time for rollover of this
counter is 61 days in a 10Mb/s repeater."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.8, aFramesTooLong."
::= { rptrMonitorPortEntry 7 }
rptrMonitorPortShortEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one for each
CarrierEvent on this port with ActivityDuration
less than ShortEventMaxTime. ShortEventMaxTime is
greater than 74 bit times and less than 82 bit
times. ShortEventMaxTime has tolerances included
to provide for circuit losses between a
conformance test point at the AUI and the
measurement point within the state machine.
Notes:
ShortEvents may indicate externally
generated noise hits which will cause the repeater
to transmit Runts to its other ports, or propagate
a collision (which may be late) back to the
transmitting DTE and damaged frames to the rest of
the network.
Implementors may wish to consider selecting the
ShortEventMaxTime towards the lower end of the
allowed tolerance range to accommodate bit losses
suffered through physical channel devices not
budgeted for within this standard.
The significance of this attribute is different
in 10 and 100 Mb/s collision domains. Clause 9
repeaters perform fragment extension of short
<span class="grey">de Graaf, et. al. Standards Track [Page 32]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-33" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
events which would be counted as runts on the
interconnect ports of other repeaters. Clause
27 repeaters do not perform fragment extension.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
The approximate minimum time for rollover of this
counter is 16 hours in a 10Mb/s repeater."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.9, aShortEvents."
::= { rptrMonitorPortEntry 8 }
rptrMonitorPortRunts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one for each
CarrierEvent on this port that meets one of the
following two conditions. Only one test need be
made. a) The ActivityDuration is greater than
ShortEventMaxTime and less than ValidPacketMinTime
and the CollisionEvent signal is deasserted. b)
The OctetCount is less than 64, the
ActivityDuration is greater than ShortEventMaxTime
and the CollisionEvent signal is deasserted.
ValidPacketMinTime is greater than or equal to 552
bit times and less than 565 bit times.
An event whose length is greater than 74 bit times
but less than 82 bit times shall increment either
the shortEvents counter or the runts counter but
not both. A CarrierEvent greater than or equal to
552 bit times but less than 565 bit times may or
may not be counted as a runt.
ValidPacketMinTime has tolerances included to
provide for circuit losses between a conformance
test point at the AUI and the measurement point
within the state machine.
Runts usually indicate collision fragments, a
normal network event. In certain situations
associated with large diameter networks a
percentage of collision fragments may exceed
ValidPacketMinTime.
<span class="grey">de Graaf, et. al. Standards Track [Page 33]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-34" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
The approximate minimum time for rollover of this
counter is 16 hours in a 10Mb/s repeater."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.10, aRunts."
::= { rptrMonitorPortEntry 9 }
rptrMonitorPortCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For a clause 9 repeater, this counter is
incremented by one for any CarrierEvent signal
on any port for which the CollisionEvent signal
on this port is asserted. For a clause 27
repeater port the counter increments on entering
the Collision Count Increment state of the
partition state diagram (fig 27-8 of
[IEEE 802.3 Std]).
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
The approximate minimum time for rollover of this
counter is 16 hours in a 10Mb/s repeater."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.11, aCollisions."
::= { rptrMonitorPortEntry 10 }
rptrMonitorPortLateEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For a clause 9 repeater port, this counter is
incremented by one for each CarrierEvent
on this port in which the CollIn(X)
variable transitions to the value SQE (Ref:
9.6.6.2, IEEE 802.3 Std) while the
ActivityDuration is greater than the
LateEventThreshold. For a clause 27 repeater
port, this counter is incremented by one on
entering the Collision Count Increment state
<span class="grey">de Graaf, et. al. Standards Track [Page 34]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-35" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
of the partition state diagram (fig 27-8)
while the ActivityDuration is greater than
the LateEvent- Threshold. Such a CarrierEvent
is counted twice, as both a collision and as a
lateEvent.
The LateEventThreshold is greater than 480 bit
times and less than 565 bit times.
LateEventThreshold has tolerances included to
permit an implementation to build a single
threshold to serve as both the LateEventThreshold
and ValidPacketMinTime threshold.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
The approximate minimum time for rollover of this
counter is 81 hours in a 10Mb/s repeater."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.12, aLateEvents."
::= { rptrMonitorPortEntry 11 }
rptrMonitorPortVeryLongEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For a clause 9 repeater port, this counter
is incremented by one for each CarrierEvent
whose ActivityDuration is greater than the
MAU Jabber Lockup Protection timer TW3
(Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std).
For a clause 27 repeater port, this counter
is incremented by one on entry to the
Rx Jabber state of the receiver timer state
diagram (fig 27-7). Other counters may
be incremented as appropriate.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.13, aVeryLongEvents."
::= { rptrMonitorPortEntry 12 }
rptrMonitorPortDataRateMismatches OBJECT-TYPE
<span class="grey">de Graaf, et. al. Standards Track [Page 35]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-36" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one for each
frame received by this port that meets all
of the conditions required by only one of the
following two measurement methods:
Measurement method A: 1) The CollisionEvent
signal is not asserted (10Mb/s operation) or
the Collision Count Increment state of the
partition state diagram (fig 27-8 of
[IEEE 802.3 Std]) has not been entered
(100Mb/s operation). 2) The ActivityDuration
is greater than ValidPacketMinTime. 3) The
frequency (data rate) is detectably mismatched
from the local transmit frequency.
Measurement method B: 1) The CollisionEvent
signal is not asserted (10Mb/s operation)
or the Collision Count Increment state of the
partition state diagram (fig 27-8 of
[IEEE 802.3 Std]) has not been entered
(100Mb/s operation). 2) The OctetCount is
greater than 63. 3) The frequency (data
rate) is detectably mismatched from the local
transmit frequency. The exact degree of
mismatch is vendor specific and is to be
defined by the vendor for conformance testing.
When this event occurs, other counters whose
increment conditions were satisfied may or may not
also be incremented, at the implementor's
discretion. Whether or not the repeater was able
to maintain data integrity is beyond the scope of
this standard.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.14, aDataRateMismatches."
::= { rptrMonitorPortEntry 13 }
rptrMonitorPortAutoPartitions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
<span class="grey">de Graaf, et. al. Standards Track [Page 36]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-37" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
STATUS current
DESCRIPTION
"This counter is incremented by one for
each time the repeater has automatically
partitioned this port.
The conditions that cause a clause 9
repeater port to partition are specified in
the partition state diagram in clause 9 of
[IEEE 802.3 Std]. They are not differentiated
here. A clause 27 repeater port partitions
on entry to the Partition Wait state of the
partition state diagram (fig 27-8 in
[IEEE 802.3 Std]).
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.15, aAutoPartitions."
::= { rptrMonitorPortEntry 14 }
rptrMonitorPortTotalErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of errors which have occurred on
this port. This counter is the summation of the
values of other error counters (for the same
port), namely:
rptrMonitorPortFCSErrors,
rptrMonitorPortAlignmentErrors,
rptrMonitorPortFrameTooLongs,
rptrMonitorPortShortEvents,
rptrMonitorPortLateEvents,
rptrMonitorPortVeryLongEvents,
rptrMonitorPortDataRateMismatches, and
rptrMonitorPortSymbolErrors.
This counter is redundant in the sense that it is
the summation of information already available
through other objects. However, it is included
specifically because the regular retrieval of this
object as a means of tracking the health of a port
provides a considerable optimization of network
management traffic over the otherwise necessary
<span class="grey">de Graaf, et. al. Standards Track [Page 37]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-38" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
retrieval of the summed counters.
Note that rptrMonitorPortRunts is not included
in this total; this is because runts usually
indicate collision fragments, a normal network
event.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes."
::= { rptrMonitorPortEntry 15 }
rptrMonitorPortLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the last of
the following occurred:
1) the agent cold- or warm-started;
2) the row for the port was created
(such as when a device or module was added
to the system); or
3) any condition that would cause one of
the counters for the row to experience
a discontinuity."
::= { rptrMonitorPortEntry 16 }
rptrMonitor100PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrMonitor100PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of additional performance and error
statistics for 100Mb/s ports, above and
beyond those parameters that apply to both
10 and 100Mbps ports. Entries exist only for
ports attached to 100Mbps repeaters.
The columnar object rptrMonitorPortLastChange
is used to indicate possible discontinuities
of counter type columnar objects in this table."
::= { rptrMonitorPortInfo 2 }
rptrMonitor100PortEntry OBJECT-TYPE
SYNTAX RptrMonitor100PortEntry
MAX-ACCESS not-accessible
STATUS current
<span class="grey">de Graaf, et. al. Standards Track [Page 38]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-39" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
DESCRIPTION
"An entry in the table, containing performance
and error statistics for a single 100Mb/s port."
INDEX { rptrMonitorPortGroupIndex, rptrMonitorPortIndex }
::= { rptrMonitor100PortTable 1 }
RptrMonitor100PortEntry ::=
SEQUENCE {
rptrMonitorPortIsolates
Counter32,
rptrMonitorPortSymbolErrors
Counter32,
rptrMonitorPortUpper32Octets
Counter32,
rptrMonitorPortHCReadableOctets
Counter64
}
rptrMonitorPortIsolates OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one each time that
the repeater port automatically isolates as a
consequence of false carrier events. The conditions
which cause a port to automatically isolate are
defined by the transition from the False Carrier
state to the Link Unstable state of the carrier
integrity state diagram (figure 27-9)
[IEEE 802.3 Standard].
Note: Isolates do not affect the value of
the PortOperStatus object.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.16, aIsolates."
::= { rptrMonitor100PortEntry 1 }
rptrMonitorPortSymbolErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one each time when
<span class="grey">de Graaf, et. al. Standards Track [Page 39]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-40" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
valid length packet was received at the port and
there was at least one occurrence of an invalid
data symbol. This can increment only once per valid
carrier event. A collision presence at any port of
the repeater containing port N, will not cause this
attribute to increment.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
The approximate minimum time for rollover of this
counter is 7.4 hours at 100Mb/s."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.17,
aSymbolErrorDuringPacket."
::= { rptrMonitor100PortEntry 2 }
rptrMonitorPortUpper32Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the number of octets contained in
valid frames that have been received on this port,
modulo 2**32. That is, it contains the upper 32
bits of a 64-bit octets counter, of which the
lower 32 bits are contained in the
rptrMonitorPortReadableOctets object.
This two-counter mechanism is provided for those
network management protocols that do not support
64-bit counters (e.g. SNMP V1) and are used to
manage a repeater type of 100Mb/s.
Conformance clauses for this MIB are defined such
that implementation of this object is not required
in a system which does not support 100Mb/s.
However, systems with mixed 10 and 100Mb/s ports
may implement this object across all ports,
including 10Mb/s. If this object is implemented,
it must be according to the definition in the first
paragraph of this description; that is, the value
of this object MUST be a valid count.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes."
<span class="grey">de Graaf, et. al. Standards Track [Page 40]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-41" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
::= { rptrMonitor100PortEntry 3 }
rptrMonitorPortHCReadableOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the number of octets contained in
valid frames that have been received on this port.
This counter is incremented by OctetCount for each
frame received on this port which has been
determined to be a readable frame (i.e., including
FCS octets but excluding framing bits and dribble
bits).
This statistic provides an indicator of the total
data transferred.
This counter is a 64-bit version of rptrMonitor-
PortReadableOctets. It should be used by network
management protocols which suppport 64-bit counters
(e.g. SNMPv2).
Conformance clauses for this MIB are defined such
that implementation of this object is not required
in a system which does not support 100Mb/s.
However, systems with mixed 10 and 100Mb/s ports
may implement this object across all ports,
including 10Mb/s. If this object is implemented,
it must be according to the definition in the first
paragraph of this description; that is, the value
of this object MUST be a valid count.
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.5, aReadableOctets."
::= { rptrMonitor100PortEntry 4 }
-- New version of statistics at the repeater level.
--
-- Statistics objects for each managed repeater
-- in the system.
rptrMonTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrMonEntry
<span class="grey">de Graaf, et. al. Standards Track [Page 41]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-42" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information about each
non-trivial repeater. The number of entries
in this table is the same as the number of
entries in the rptrInfoTable.
The columnar object rptrInfoLastChange is
used to indicate possible discontinuities of
counter type columnar objects in this table."
::= { rptrMonitorAllRptrInfo 1 }
rptrMonEntry OBJECT-TYPE
SYNTAX RptrMonEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing information
about a single non-trivial repeater."
INDEX { rptrInfoId }
::= { rptrMonTable 1 }
RptrMonEntry ::=
SEQUENCE {
rptrMonTxCollisions
Counter32,
rptrMonTotalFrames
Counter32,
rptrMonTotalErrors
Counter32,
rptrMonTotalOctets
Counter32
}
rptrMonTxCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For a clause 9 (10Mb/s) repeater, this counter
is incremented every time the repeater state
machine enters the TRANSMIT COLLISION state
from any state other than ONE PORT LEFT
(Ref: Fig 9-2 [IEEE 802.3 Std]).
For a clause 27 repeater, this counter is
incremented every time the repeater core state
<span class="grey">de Graaf, et. al. Standards Track [Page 42]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-43" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
diagram enters the Jam state as a result of
Activity(ALL) > 1 (fig 27-2 [IEEE 802.3 Std]).
The approximate minimum time for rollover of this
counter is 16 hours in a 10Mb/s repeater and 1.6
hours in a 100Mb/s repeater."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.1.8, aTransmitCollisions"
::= { rptrMonEntry 1 }
rptrMonTotalFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames of valid frame length
that have been received on the ports in this repeater
and for which the FCSError and CollisionEvent
signals were not asserted. If an implementation
can not obtain a count of frames as seen by
the repeater itself, this counter may be
implemented as the summation of the values of the
rptrMonitorPortReadableFrames counters for all of
the ports in the repeater.
This statistic provides one of the parameters
necessary for obtaining the packet error rate.
The approximate minimum time for rollover of this
counter is 80 hours in a 10Mb/s repeater."
::= { rptrMonEntry 3 }
rptrMonTotalErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of errors which have occurred on
all of the ports in this repeater. The errors
included in this count are the same as those listed
for the rptrMonitorPortTotalErrors counter. If an
implementation can not obtain a count of these
errors as seen by the repeater itself, this counter
may be implemented as the summation of the values of
the rptrMonitorPortTotalErrors counters for all of
the ports in the repeater."
::= { rptrMonEntry 4 }
rptrMonTotalOctets OBJECT-TYPE
<span class="grey">de Graaf, et. al. Standards Track [Page 43]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-44" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets contained in the valid
frames that have been received on the ports in
this group. If an implementation can not obtain
a count of octets as seen by the repeater itself,
this counter may be the summation of the
values of the rptrMonitorPortReadableOctets
counters for all of the ports in the group.
This statistic provides an indicator of the total
data transferred. The approximate minimum time
for rollover of this counter in a 10Mb/s repeater
is 58 minutes divided by the number of ports in
the repeater.
For 100Mb/s repeaters processing traffic at a
maximum rate, this counter can roll over in less
than 6 minutes divided by the number of ports in
the repeater. Since that amount of time could
be less than a management station's poll cycle
time, in order to avoid a loss of information a
management station is advised to also poll the
rptrMonUpper32TotalOctets object, or to use the
64-bit counter defined by rptrMonHCTotalOctets
instead of the two 32-bit counters."
::= { rptrMonEntry 5 }
rptrMon100Table OBJECT-TYPE
SYNTAX SEQUENCE OF RptrMon100Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of additional information about each
100Mb/s repeater, augmenting the entries in
the rptrMonTable. Entries exist in this table
only for 100Mb/s repeaters.
The columnar object rptrInfoLastChange is
used to indicate possible discontinuities of
counter type columnar objects in this table."
::= { rptrMonitorAllRptrInfo 2 }
rptrMon100Entry OBJECT-TYPE
SYNTAX RptrMon100Entry
MAX-ACCESS not-accessible
<span class="grey">de Graaf, et. al. Standards Track [Page 44]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-45" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
STATUS current
DESCRIPTION
"An entry in the table, containing information
about a single 100Mbps repeater."
INDEX { rptrInfoId }
::= { rptrMon100Table 1 }
RptrMon100Entry ::=
SEQUENCE {
rptrMonUpper32TotalOctets
Counter32,
rptrMonHCTotalOctets
Counter64
}
rptrMonUpper32TotalOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets contained in the valid
frames that have been received on the ports in
this repeater, modulo 2**32. That is, it contains
the upper 32 bits of a 64-bit counter, of which
the lower 32 bits are contained in the
rptrMonTotalOctets object. If an implementation
can not obtain a count of octets as seen
by the repeater itself, the 64-bit value
may be the summation of the values of the
rptrMonitorPortReadableOctets counters combined
with the corresponding rptrMonitorPortUpper32Octets
counters for all of the ports in the repeater.
This statistic provides an indicator of the total
data transferred within the repeater.
This two-counter mechanism is provided for those
network management protocols that do not support
64-bit counters (e.g. SNMP V1) and are used to
manage a repeater type of 100Mb/s.
Conformance clauses for this MIB are defined such
that implementation of this object is not required
in a system which does not support 100Mb/s.
However, systems with mixed 10 and 100Mb/s ports
may implement this object across all ports,
including 10Mb/s. If this object is implemented,
it must be according to the definition in the first
<span class="grey">de Graaf, et. al. Standards Track [Page 45]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-46" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
paragraph of this description; that is, the value
of this object MUST be a valid count."
::= { rptrMon100Entry 1 }
rptrMonHCTotalOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets contained in the valid
frames that have been received on the ports in
this group. If a implementation can not obtain
a count of octets as seen by the repeater itself,
this counter may be the summation of the
values of the rptrMonitorPortReadableOctets
counters for all of the ports in the group.
This statistic provides an indicator of the total
data transferred.
This counter is a 64-bit (high-capacity) version
of rptrMonUpper32TotalOctets and rptrMonTotalOctets.
It should be used by network management protocols
which support 64-bit counters (e.g. SNMPv2).
Conformance clauses for this MIB are defined such
that implementation of this object is not required
in a system which does not support 100Mb/s.
However, systems with mixed 10 and 100Mb/s ports
may implement this object across all ports,
including 10Mb/s. If this object is implemented,
it must be according to the definition in the first
paragraph of this description; that is, the value
of this object MUST be a valid count."
::= { rptrMon100Entry 2 }
--
-- The Repeater Address Search Table
--
-- This table provides an active address tracking
-- capability which can be also used to collect the
-- necessary information for mapping the topology
-- of a network. Note that an NMS is required to have
-- read-write access to the table in order to access
-- this function. <a href="#section-4">Section 4</a>, "Topology Mapping",
-- contains a description of an algorithm which can
-- make use of this table, in combination with the
<span class="grey">de Graaf, et. al. Standards Track [Page 46]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-47" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
-- forwarding databases of managed bridges/switches
-- in the network, to map network topology.
--
rptrAddrSearchTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrAddrSearchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one entry per repeater in the
system. It defines objects which allow a network
management application to instruct an agent to watch
for a given MAC address and report which port it
was seen on. Only one address search can be in
progress on each repeater at any one time. Before
starting an address search, a management application
should obtain 'ownership' of the entry in
rptrAddrSearchTable for the repeater that is to
perform the search. This is accomplished with the
rptrAddrSearchLock and rptrAddrSearchStatus as
follows:
try_again:
get(rptrAddrSearchLock, rptrAddrSearchStatus)
while (rptrAddrSearchStatus != notInUse)
{
/* Loop waiting for objects to be available*/
short delay
get(rptrAddrSearchLock, rptrAddrSearchStatus)
}
/* Try to claim map objects */
lock_value = rptrAddrSearchLock
if ( set(rptrAddrSearchLock = lock_value,
rptrAddrSearchStatus = inUse,
rptrAddrSearchOwner = 'my-IP-address)
== FAILURE)
/* Another manager got the lock */
goto try_again
/* I have the lock */
set (rptrAddrSearchAddress = <search target>)
wait for rptrAddrSearchState to change from none
if (rptrAddrSearchState == single)
get (rptrAddrSearchGroup, rptrAddrSearchPort)
<span class="grey">de Graaf, et. al. Standards Track [Page 47]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-48" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
/* release the lock, making sure not to overwrite
anyone else's lock */
set (rptrAddrSearchLock = lock_value+1,
rptrAddrSearchStatus = notInUse,
rptrAddrSearchOwner = '')
A management station first retrieves the values of
the appropriate instances of the rptrAddrSearchLock
and rptrAddrSearchStatus objects, periodically
repeating the retrieval if necessary, until the value
of rptrAddrSearchStatus is 'notInUse'. The
management station then tries to set the same
instance of the rptrAddrSearchLock object to the
value it just retrieved, the same instance of the
rptrAddrSearchStatus object to 'inUse', and the
corresponding instance of rptrAddrSearchOwner to a
value indicating itself. If the set operation
succeeds, then the management station has obtained
ownership of the rptrAddrSearchEntry, and the value
of rptrAddrSearchLock is incremented by the agent (as
per the semantics of TestAndIncr). Failure of the
set operation indicates that some other manager has
obtained ownership of the rptrAddrSearchEntry.
Once ownership is obtained, the management station
can proceed with the search operation. Note that the
agent will reset rptrAddrSearchStatus to 'notInUse'
if it has been in the 'inUse' state for an abnormally
long period of time, to prevent a misbehaving manager
from permanently locking the entry. It is suggested
that this timeout period be between one and five
minutes.
When the management station has completed its search
operation, it should free the entry by setting
the instance of the rptrAddrSearchLock object to the
previous value + 1, the instance of the
rptrAddrSearchStatus to 'notInUse', and the instance
of rptrAddrSearchOwner to a zero length string. This
is done to prevent overwriting another station's
lock."
::= { rptrAddrTrackRptrInfo 1 }
rptrAddrSearchEntry OBJECT-TYPE
SYNTAX RptrAddrSearchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
<span class="grey">de Graaf, et. al. Standards Track [Page 48]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-49" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
"An entry containing objects for invoking an address
search on a repeater."
INDEX { rptrInfoId }
::= { rptrAddrSearchTable 1 }
RptrAddrSearchEntry ::=
SEQUENCE {
rptrAddrSearchLock TestAndIncr,
rptrAddrSearchStatus INTEGER,
rptrAddrSearchAddress MacAddress,
rptrAddrSearchState INTEGER,
rptrAddrSearchGroup Integer32,
rptrAddrSearchPort Integer32,
rptrAddrSearchOwner OwnerString
}
rptrAddrSearchLock OBJECT-TYPE
SYNTAX TestAndIncr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used by a management station as an
advisory lock for this rptrAddrSearchEntry."
::= { rptrAddrSearchEntry 1 }
rptrAddrSearchStatus OBJECT-TYPE
SYNTAX INTEGER {
notInUse(1),
inUse(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to indicate that some management
station is currently using this rptrAddrSearchEntry.
Cooperating managers should set this object to
'notInUse' when they are finished using this entry.
The agent will automatically set the value of this
object to 'notInUse' if it has been set to 'inUse'
for an unusually long period of time."
::= { rptrAddrSearchEntry 2 }
rptrAddrSearchAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
<span class="grey">de Graaf, et. al. Standards Track [Page 49]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-50" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
"This object is used to search for a specified MAC
address. When this object is set, an address search
begins. This automatically sets the corresponding
instance of the rptrAddrSearchState object to 'none'
and the corresponding instances of the
rptrAddrSearchGroup and rptrAddrSearchPort objects to
0.
When a valid frame is received by this repeater with
a source MAC address which matches the current value
of rptrAddrSearchAddress, the agent will update the
corresponding instances of rptrAddrSearchState,
rptrAddrSearchGroup and rptrAddrSearchPort to reflect
the current status of the search, and the group and
port on which the frame was seen."
::= { rptrAddrSearchEntry 3 }
rptrAddrSearchState OBJECT-TYPE
SYNTAX INTEGER {
none(1),
single(2),
multiple(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the MAC address search on this
repeater. This object is initialized to 'none' when
the corresponding instance of rptrAddrSearchAddress
is set. If the agent detects the address on exactly
one port, it will set this object to 'single', and
set the corresponding instances of
rptrAddrSearchGroup and rptrAddrSearchPort to reflect
the group and port on which the address was heard.
If the agent detects the address on more than one
port, it will set this object to 'multiple'."
::= { rptrAddrSearchEntry 4 }
rptrAddrSearchGroup OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group from which an error-free frame whose
source address is equal to the corresponding instance
of rptrAddrSearchAddress has been received. The
value of this object is undefined when the
corresponding instance of rptrAddrSearchState is
<span class="grey">de Graaf, et. al. Standards Track [Page 50]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-51" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
equal to 'none' or 'multiple'."
::= { rptrAddrSearchEntry 5 }
rptrAddrSearchPort OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port rom which an error-free frame whose
source address is equal to the corresponding instance
of rptrAddrSearchAddress has been received. The
value of this object is undefined when the
corresponding instance of rptrAddrSearchState is
equal to 'none' or 'multiple'."
::= { rptrAddrSearchEntry 6 }
rptrAddrSearchOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The entity which currently has 'ownership' of this
rptrAddrSearchEntry."
::= { rptrAddrSearchEntry 7 }
--
-- The Port Address Tracking Table
--
-- This table provides a way for a network management
-- application to passively gather information (using
-- read-only privileges) about which network addresses
-- are connected to which ports of a repeater.
--
rptrAddrTrackTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrAddrTrackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of address mapping information about the
ports."
::= { rptrAddrTrackPortInfo 1 }
rptrAddrTrackEntry OBJECT-TYPE
SYNTAX RptrAddrTrackEntry
MAX-ACCESS not-accessible
STATUS current
<span class="grey">de Graaf, et. al. Standards Track [Page 51]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-52" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
DESCRIPTION
"An entry in the table, containing address mapping
information about a single port."
INDEX { rptrAddrTrackGroupIndex, rptrAddrTrackPortIndex }
::= { rptrAddrTrackTable 1 }
RptrAddrTrackEntry ::=
SEQUENCE {
rptrAddrTrackGroupIndex
INTEGER,
rptrAddrTrackPortIndex
INTEGER,
rptrAddrTrackLastSourceAddress -- DEPRECATED OBJECT
MacAddress,
rptrAddrTrackSourceAddrChanges
Counter32,
rptrAddrTrackNewLastSrcAddress
OptMacAddr,
rptrAddrTrackCapacity
Integer32
}
rptrAddrTrackGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the group containing the
port for which this entry contains information."
::= { rptrAddrTrackEntry 1 }
rptrAddrTrackPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the port within the group
for which this entry contains information."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID."
::= { rptrAddrTrackEntry 2 }
rptrAddrTrackLastSourceAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
<span class="grey">de Graaf, et. al. Standards Track [Page 52]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-53" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
This object is the SourceAddress of the last
readable frame (i.e., counted by
rptrMonitorPortReadableFrames) received by this
port.
This object has been deprecated because its value
is undefined when no frames have been observed on
this port. The replacement object is
rptrAddrTrackNewLastSrcAddress."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress."
::= { rptrAddrTrackEntry 3 }
rptrAddrTrackSourceAddrChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one for each time
that the rptrAddrTrackLastSourceAddress attribute
for this port has changed.
This may indicate whether a link is connected to a
single DTE or another multi-user segment.
A discontinuity may occur in the value when the
value of object rptrMonitorPortLastChange changes.
The approximate minimum time for rollover of this
counter is 81 hours in a 10Mb/s repeater."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.19, aSourceAddressChanges."
::= { rptrAddrTrackEntry 4 }
rptrAddrTrackNewLastSrcAddress OBJECT-TYPE
SYNTAX OptMacAddr
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the SourceAddress of the last
readable frame (i.e., counted by
rptrMonitorPortReadableFrames) received by this
port. If no frames have been received by this
port since the agent began monitoring the port
activity, the agent shall return a string of
length zero."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress."
<span class="grey">de Graaf, et. al. Standards Track [Page 53]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-54" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
::= { rptrAddrTrackEntry 5 }
rptrAddrTrackCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of addresses that can be
detected on this port. This value indicates
to the maximum number of entries in the
rptrExtAddrTrackTable relative to this port.
If this object has the value of 1, the agent
implements only the LastSourceAddress mechanism
described by <a href="./rfc1368">RFC 1368</a> or <a href="./rfc1516">RFC 1516</a>."
::= { rptrAddrTrackEntry 6 }
-- Table for multiple addresses per port
rptrExtAddrTrackTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrExtAddrTrackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table to extend the address tracking table (i.e.,
rptrAddrTrackTable) with a list of source MAC
addresses that were recently received on each port.
The number of ports is the same as the number
of entries in table rptrPortTable. The number of
entries in this table depends on the agent/repeater
implementation and the number of different
addresses received on each port.
The first entry for each port contains
the same MAC address that is given by the
rptrAddrTrackNewLastSrcAddress for that port.
Entries in this table for a particular port are
retained when that port is switched from one
repeater to another.
The ordering of MAC addresses listed for a
particular port is implementation dependent."
::= { rptrAddrTrackPortInfo 2 }
rptrExtAddrTrackEntry OBJECT-TYPE
SYNTAX RptrExtAddrTrackEntry
<span class="grey">de Graaf, et. al. Standards Track [Page 54]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-55" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the table of extended address tracking
information for ports. Entries can not be directly
created or deleted via SNMP operations."
INDEX { rptrAddrTrackGroupIndex,
rptrAddrTrackPortIndex,
rptrExtAddrTrackMacIndex }
::= { rptrExtAddrTrackTable 1 }
RptrExtAddrTrackEntry ::= SEQUENCE {
rptrExtAddrTrackMacIndex Integer32,
rptrExtAddrTrackSourceAddress MacAddress
}
rptrExtAddrTrackMacIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of a source MAC address seen on
the port.
The ordering of MAC addresses listed for a
particular port is implementation dependent.
There is no implied relationship between a
particular index and a particular MAC
address. The index for a particular MAC
address may change without notice."
::= { rptrExtAddrTrackEntry 1 }
rptrExtAddrTrackSourceAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source MAC address from a readable frame
(i.e., counted by rptrMonitorPortReadableFrames)
recently received by the port."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress."
::= { rptrExtAddrTrackEntry 2 }
-- The Repeater Top "N" Port Group
<span class="grey">de Graaf, et. al. Standards Track [Page 55]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-56" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
-- The Repeater Top N Port group is used to prepare reports that
-- describe a list of ports ordered by one of the statistics in the
-- Repeater Monitor Port Table. The statistic chosen by the
-- management station is sampled over a management
-- station-specified time interval, making the report rate based.
-- The management station also specifies the number of ports that
-- are reported.
--
-- The rptrTopNPortControlTable is used to initiate the generation
-- of a report. The management station may select the parameters
-- of such a report, such as which repeater, which statistic, how
-- many ports, and the start & stop times of the sampling. When
-- the report is prepared, entries are created in the
-- rptrTopNPortTable associated with the relevent
-- rptrTopNControlEntry. These entries are static for
-- each report after it has been prepared.
-- Note that counter discontinuities may appear in some
-- implementations if ports' assignment to repeaters changes
-- during the collection of data for a Top "N" report.
-- A management application could read the corresponding
-- rptrMonitorPortLastChange timestamp in order to check
-- whether a discontinuity occurred.
rptrTopNPortControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrTopNPortControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of control records for reports on the top `N'
ports for the rate of a selected counter. The number
of entries depends on the configuration of the agent.
The maximum number of entries is implementation
dependent."
::= { rptrTopNPortInfo 1 }
rptrTopNPortControlEntry OBJECT-TYPE
SYNTAX RptrTopNPortControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters that control the creation of a
report of the top N ports according to several metrics."
INDEX { rptrTopNPortControlIndex }
::= { rptrTopNPortControlTable 1 }
RptrTopNPortControlEntry ::= SEQUENCE {
<span class="grey">de Graaf, et. al. Standards Track [Page 56]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-57" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
rptrTopNPortControlIndex
Integer32,
rptrTopNPortRepeaterId
Integer32,
rptrTopNPortRateBase
INTEGER,
rptrTopNPortTimeRemaining
Integer32,
rptrTopNPortDuration
Integer32,
rptrTopNPortRequestedSize
Integer32,
rptrTopNPortGrantedSize
Integer32,
rptrTopNPortStartTime
TimeStamp,
rptrTopNPortOwner
OwnerString,
rptrTopNPortRowStatus
RowStatus
}
rptrTopNPortControlIndex OBJECT-TYPE
SYNTAX Integer32 (1 .. 65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
rptrTopNPortControl table. Each such entry defines
one top N report prepared for a repeater or system."
::= { rptrTopNPortControlEntry 1 }
rptrTopNPortRepeaterId OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Identifies the repeater for which a top N report will
be prepared (see rptrInfoId). If the value of this
object is positive, only ports assigned to this repeater
will be used to form the list in which to order the
Top N table. If this value is zero, all ports will be
eligible for inclusion on the list.
The value of this object may not be modified if the
associated rptrTopNPortRowStatus object is equal to
active(1).
<span class="grey">de Graaf, et. al. Standards Track [Page 57]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-58" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
If, for a particular row in this table, the repeater
specified by the value of this object goes away (is
removed from the rptrInfoTable) while the associated
rptrTopNPortRowStatus object is equal to active(1),
the row in this table is preserved by the agent but
the value of rptrTopNPortRowStatus is changed to
notInService(2), and the agent may time out the row
if appropriate. If the specified repeater comes
back (reappears in the rptrInfoTable) before the row
has been timed out, the management station must set
the value of the rptrTopNPortRowStatus object back
to active(1) if desired (the agent doesn't do this
automatically)."
::= { rptrTopNPortControlEntry 2 }
rptrTopNPortRateBase OBJECT-TYPE
SYNTAX INTEGER {
readableFrames(1),
readableOctets(2),
fcsErrors(3),
alignmentErrors(4),
frameTooLongs(5),
shortEvents(6),
runts(7),
collisions(8),
lateEvents(9),
veryLongEvents(10),
dataRateMismatches(11),
autoPartitions(12),
totalErrors(13),
isolates(14),
symbolErrors(15)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The monitored variable, which the rptrTopNPortRate
variable is based upon.
The value of this object may not be modified if
the associated rptrTopNPortRowStatus object has
a value of active(1)."
::= { rptrTopNPortControlEntry 3 }
rptrTopNPortTimeRemaining OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
<span class="grey">de Graaf, et. al. Standards Track [Page 58]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-59" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
DESCRIPTION
"The number of seconds left in the report
currently being collected. When this object
is modified by the management station, a new
collection is started, possibly aborting a
currently running report. The new value is
used as the requested duration of this report,
which is loaded into the associated
rptrTopNPortDuration object.
When this object is set to a non-zero value,
any associated rptrTopNPortEntries shall be
made inaccessible by the agent. While the value
of this object is non-zero, it decrements by one
per second until it reaches zero. During this
time, all associated rptrTopNPortEntries shall
remain inaccessible. At the time that this object
decrements to zero, the report is made accessible
in the rptrTopNPortTable. Thus, the rptrTopNPort
table needs to be created only at the end of the
collection interval.
If the value of this object is set to zero
while the associated report is running, the
running report is aborted and no associated
rptrTopNPortEntries are created."
DEFVAL { 0 }
::= { rptrTopNPortControlEntry 4 }
rptrTopNPortDuration OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that this report has
collected during the last sampling interval,
or if this report is currently being collected,
the number of seconds that this report is being
collected during this sampling interval.
When the associated rptrTopNPortTimeRemaining
object is set, this object shall be set by the
agent to the same value and shall not be modified
until the next time the rptrTopNPortTimeRemaining
is set.
This value shall be zero if no reports have been
requested for this rptrTopNPortControlEntry."
<span class="grey">de Graaf, et. al. Standards Track [Page 59]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-60" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
::= { rptrTopNPortControlEntry 5 }
rptrTopNPortRequestedSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of repeater ports requested
for the Top N Table.
When this object is created or modified, the
agent should set rptrTopNPortGrantedSize as close
to this object as is possible for the particular
implementation and available resources."
DEFVAL { 10 }
::= { rptrTopNPortControlEntry 6 }
rptrTopNPortGrantedSize OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of repeater ports in the
top N table.
When the associated rptrTopNPortRequestedSize object is
created or modified, the agent should set this object as
closely to the requested value as is possible for the
particular implementation and available resources. The
agent must not lower this value except as a result of a
set to the associated rptrTopNPortRequestedSize object."
::= { rptrTopNPortControlEntry 7 }
rptrTopNPortStartTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this top N report was
last started. In other words, this is the time that
the associated rptrTopNPortTimeRemaining object was
modified to start the requested report.
If the report has not yet been started, the value
of this object is zero."
::= { rptrTopNPortControlEntry 8 }
rptrTopNPortOwner OBJECT-TYPE
<span class="grey">de Graaf, et. al. Standards Track [Page 60]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-61" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is
using the resources assigned to it."
::= { rptrTopNPortControlEntry 9 }
rptrTopNPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this row.
If the value of this object is not equal to
active(1), all associated entries in the
rptrTopNPortTable shall be deleted by the
agent."
::= { rptrTopNPortControlEntry 10 }
-- Top "N" reports
rptrTopNPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrTopNPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of reports for the top `N' ports based on
setting of associated control table entries. The
maximum number of entries depends on the number
of entries in table rptrTopNPortControlTable and
the value of object rptrTopNPortGrantedSize for
each entry.
For each entry in the rptrTopNPortControlTable,
repeater ports with the highest value of
rptrTopNPortRate shall be placed in this table
in decreasing order of that rate until there is
no more room or until there are no more ports."
::= { rptrTopNPortInfo 2 }
rptrTopNPortEntry OBJECT-TYPE
SYNTAX RptrTopNPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
<span class="grey">de Graaf, et. al. Standards Track [Page 61]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-62" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
"A set of statistics for a repeater port that is
part of a top N report."
INDEX { rptrTopNPortControlIndex,
rptrTopNPortIndex }
::= { rptrTopNPortTable 1 }
RptrTopNPortEntry ::= SEQUENCE {
rptrTopNPortIndex
Integer32,
rptrTopNPortGroupIndex
Integer32,
rptrTopNPortPortIndex
Integer32,
rptrTopNPortRate
Gauge32
}
rptrTopNPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in
the rptrTopNPort table among those in the same
report. This index is between 1 and N, where N
is the number of entries in this report. Increasing
values of rptrTopNPortIndex shall be assigned to
entries with decreasing values of rptrTopNPortRate
until index N is assigned to the entry with the
lowest value of rptrTopNPortRate or there are no
more rptrTopNPortEntries.
No ports are included in a report where their
value of rptrTopNPortRate would be zero."
::= { rptrTopNPortEntry 1 }
rptrTopNPortGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifes the group containing
the port for this entry. (See also object
type rptrGroupIndex.)"
::= { rptrTopNPortEntry 2 }
rptrTopNPortPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
<span class="grey">de Graaf, et. al. Standards Track [Page 62]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-63" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the repeater port.
(See object type rptrPortIndex.)"
::= { rptrTopNPortEntry 3 }
rptrTopNPortRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of change in the selected variable
during this sampling interval for the identified
port. The selected variable is that port's
instance of the object selected by
rptrTopNPortRateBase."
::= { rptrTopNPortEntry 4 }
-- Notifications for use by Repeaters
rptrHealth NOTIFICATION-TYPE
OBJECTS { rptrOperStatus }
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
In a system containing a single managed repeater,
the rptrHealth notification conveys information
related to the operational status of the repeater.
It is sent either when the value of
rptrOperStatus changes, or upon completion of a
non-disruptive test.
The rptrHealth notification must contain the
rptrOperStatus object. The agent may optionally
include the rptrHealthText object in the varBind
list. See the rptrOperStatus and rptrHealthText
objects for descriptions of the information that
is sent.
The agent must throttle the generation of
consecutive rptrHealth traps so that there is at
least a five-second gap between traps of this
type. When traps are throttled, they are dropped,
not queued for sending at a future time. (Note
<span class="grey">de Graaf, et. al. Standards Track [Page 63]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-64" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
that 'generating' a trap means sending to all
configured recipients.)"
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.3.1, nRepeaterHealth
notification."
::= { snmpDot3RptrMgt 0 1 }
rptrGroupChange NOTIFICATION-TYPE
OBJECTS { rptrGroupIndex }
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
In a system containing a single managed repeater,
this notification is sent when a change occurs in the
group structure of the repeater. This occurs only
when a group is logically or physically removed
from or added to a repeater. The varBind list
contains the identifier of the group that was
removed or added.
The agent must throttle the generation of
consecutive rptrGroupChange traps for the same
group so that there is at least a five-second gap
between traps of this type. When traps are
throttled, they are dropped, not queued for
sending at a future time. (Note that 'generating'
a trap means sending to all configured
recipients.)"
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.3.3, nGroupMapChange
notification."
::= { snmpDot3RptrMgt 0 2 }
rptrResetEvent NOTIFICATION-TYPE
OBJECTS { rptrOperStatus }
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
In a system containing a single managed repeater-unit,
the rptrResetEvent notification conveys information
related to the operational status of the repeater.
This trap is sent on completion of a repeater
reset action. A repeater reset action is defined
as an a transition to the START state of Fig 9-2
in <a href="#section-9">section 9</a> [IEEE 802.3 Std], when triggered by a
management command (e.g., an SNMP Set on the
<span class="grey">de Graaf, et. al. Standards Track [Page 64]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-65" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
rptrReset object).
The agent must throttle the generation of
consecutive rptrResetEvent traps so that there is
at least a five-second gap between traps of this
type. When traps are throttled, they are dropped,
not queued for sending at a future time. (Note
that 'generating' a trap means sending to all
configured recipients.)
The rptrResetEvent trap is not sent when the agent
restarts and sends an SNMP coldStart or warmStart
trap. However, it is recommended that a repeater
agent send the rptrOperStatus object as an
optional object with its coldStart and warmStart
trap PDUs.
The rptrOperStatus object must be included in the
varbind list sent with this trap. The agent may
optionally include the rptrHealthText object as
well."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.3.2, nRepeaterReset
notification."
::= { snmpDot3RptrMgt 0 3 }
-- Notifications for repeaters in a multiple-repeater implementation.
-- An implementation may send either the single-repeater OR
-- multiple-repeater version of these notifications (1 or 4; 2 or 5)
-- but not both.
rptrInfoHealth NOTIFICATION-TYPE
OBJECTS { rptrInfoOperStatus }
STATUS current
DESCRIPTION
"In a system containing multiple managed repeaters,
the rptrInfoHealth notification conveys information
related to the operational status of a repeater.
It is sent either when the value of rptrInfoOperStatus
changes, or upon completion of a non-disruptive test.
The agent must throttle the generation of
consecutive rptrInfoHealth notifications for
the same repeater so that there is at least
a five-second gap between notifications of this type.
When notifications are throttled, they are dropped,
not queued for sending at a future time. (Note
<span class="grey">de Graaf, et. al. Standards Track [Page 65]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-66" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
that 'generating' a notification means sending
to all configured recipients.)"
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.3.1, nRepeaterHealth
notification."
::= { snmpDot3RptrMgt 0 4 }
rptrInfoResetEvent NOTIFICATION-TYPE
OBJECTS { rptrInfoOperStatus }
STATUS current
DESCRIPTION
"In a system containing multiple managed
repeaters, the rptrInfoResetEvent notification
conveys information related to the operational
status of a repeater. This notification is sent
on completion of a repeater reset action. A
repeater reset action is defined as a transition
to the START state of Fig 9-2 in <a href="#section-9">section 9</a> of
[IEEE 802.3 Std], when triggered by a management
command (e.g., an SNMP Set on the rptrInfoReset
object).
The agent must throttle the generation of
consecutive rptrInfoResetEvent notifications for
a single repeater so that there is at least
a five-second gap between notifications of
this type. When notifications are throttled,
they are dropped, not queued for sending at
a future time. (Note that 'generating' a
notification means sending to all configured
recipients.)
The rptrInfoResetEvent is not sent when the
agent restarts and sends an SNMP coldStart or
warmStart trap. However, it is recommended that
a repeater agent send the rptrInfoOperStatus
object as an optional object with its coldStart
and warmStart trap PDUs."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.3.2, nRepeaterReset
notification."
::= { snmpDot3RptrMgt 0 5 }
-- Conformance information
snmpRptrModConf
OBJECT IDENTIFIER ::= { snmpRptrMod 1 }
<span class="grey">de Graaf, et. al. Standards Track [Page 66]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-67" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
snmpRptrModCompls
OBJECT IDENTIFIER ::= { snmpRptrModConf 1 }
snmpRptrModObjGrps
OBJECT IDENTIFIER ::= { snmpRptrModConf 2 }
snmpRptrModNotGrps
OBJECT IDENTIFIER ::= { snmpRptrModConf 3 }
-- Object groups
snmpRptrGrpBasic1516 OBJECT-GROUP
OBJECTS { rptrGroupCapacity,
rptrOperStatus,
rptrHealthText,
rptrReset,
rptrNonDisruptTest,
rptrTotalPartitionedPorts,
rptrGroupIndex,
rptrGroupDescr,
rptrGroupObjectID,
rptrGroupOperStatus,
rptrGroupLastOperStatusChange,
rptrGroupPortCapacity,
rptrPortGroupIndex,
rptrPortIndex,
rptrPortAdminStatus,
rptrPortAutoPartitionState,
rptrPortOperStatus }
STATUS deprecated
DESCRIPTION
"********* THIS GROUP IS DEPRECATED **********
Basic group from RFCs 1368 and 1516.
NOTE: this object group is DEPRECATED and replaced
with snmpRptrGrpBasic."
::= { snmpRptrModObjGrps 1 }
snmpRptrGrpMonitor1516 OBJECT-GROUP
OBJECTS { rptrMonitorTransmitCollisions,
rptrMonitorGroupIndex,
rptrMonitorGroupTotalFrames,
rptrMonitorGroupTotalOctets,
rptrMonitorGroupTotalErrors,
<span class="grey">de Graaf, et. al. Standards Track [Page 67]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-68" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
rptrMonitorPortGroupIndex,
rptrMonitorPortIndex,
rptrMonitorPortReadableFrames,
rptrMonitorPortReadableOctets,
rptrMonitorPortFCSErrors,
rptrMonitorPortAlignmentErrors,
rptrMonitorPortFrameTooLongs,
rptrMonitorPortShortEvents,
rptrMonitorPortRunts,
rptrMonitorPortCollisions,
rptrMonitorPortLateEvents,
rptrMonitorPortVeryLongEvents,
rptrMonitorPortDataRateMismatches,
rptrMonitorPortAutoPartitions,
rptrMonitorPortTotalErrors }
STATUS deprecated
DESCRIPTION
"********* THIS GROUP IS DEPRECATED **********
Monitor group from RFCs 1368 and 1516.
NOTE: this object group is DEPRECATED and replaced
with snmpRptrGrpMonitor."
::= { snmpRptrModObjGrps 2 }
snmpRptrGrpAddrTrack1368 OBJECT-GROUP
OBJECTS { rptrAddrTrackGroupIndex,
rptrAddrTrackPortIndex,
rptrAddrTrackLastSourceAddress,
rptrAddrTrackSourceAddrChanges }
STATUS obsolete
DESCRIPTION
"Address tracking group from <a href="./rfc1368">RFC 1368</a>.
NOTE: this object group is OBSOLETE and replaced
with snmpRptrGrpAddrTrack1516."
::= { snmpRptrModObjGrps 3 }
snmpRptrGrpAddrTrack1516 OBJECT-GROUP
OBJECTS { rptrAddrTrackGroupIndex,
rptrAddrTrackPortIndex,
rptrAddrTrackLastSourceAddress,
rptrAddrTrackSourceAddrChanges,
rptrAddrTrackNewLastSrcAddress }
STATUS deprecated
DESCRIPTION
"********* THIS GROUP IS DEPRECATED **********
<span class="grey">de Graaf, et. al. Standards Track [Page 68]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-69" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
Address tracking group from <a href="./rfc1516">RFC 1516</a>.
NOTE: this object group is DEPRECATED and
replaced with snmpRptrGrpAddrTrack."
::= { snmpRptrModObjGrps 4 }
snmpRptrGrpBasic OBJECT-GROUP
OBJECTS { rptrGroupIndex,
rptrGroupObjectID,
rptrGroupOperStatus,
rptrGroupPortCapacity,
rptrPortGroupIndex,
rptrPortIndex,
rptrPortAdminStatus,
rptrPortAutoPartitionState,
rptrPortOperStatus,
rptrPortRptrId,
rptrInfoId,
rptrInfoRptrType,
rptrInfoOperStatus,
rptrInfoReset,
rptrInfoPartitionedPorts,
rptrInfoLastChange }
STATUS current
DESCRIPTION
"Basic group for a system with one or more
repeater-units in multi-segment (post-RFC 1516)
version of the MIB module."
::= { snmpRptrModObjGrps 5 }
snmpRptrGrpMonitor OBJECT-GROUP
OBJECTS { rptrMonitorPortGroupIndex,
rptrMonitorPortIndex,
rptrMonitorPortReadableFrames,
rptrMonitorPortReadableOctets,
rptrMonitorPortFCSErrors,
rptrMonitorPortAlignmentErrors,
rptrMonitorPortFrameTooLongs,
rptrMonitorPortShortEvents,
rptrMonitorPortRunts,
rptrMonitorPortCollisions,
rptrMonitorPortLateEvents,
rptrMonitorPortVeryLongEvents,
rptrMonitorPortDataRateMismatches,
rptrMonitorPortAutoPartitions,
rptrMonitorPortTotalErrors,
<span class="grey">de Graaf, et. al. Standards Track [Page 69]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-70" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
rptrMonitorPortLastChange,
rptrMonTxCollisions,
rptrMonTotalFrames,
rptrMonTotalErrors,
rptrMonTotalOctets }
STATUS current
DESCRIPTION
"Monitor group for a system with one or more
repeater-units in multi-segment (post-RFC 1516)
version of the MIB module."
::= { snmpRptrModObjGrps 6 }
snmpRptrGrpMonitor100 OBJECT-GROUP
OBJECTS { rptrMonitorPortIsolates,
rptrMonitorPortSymbolErrors,
rptrMonitorPortUpper32Octets,
rptrMonUpper32TotalOctets }
STATUS current
DESCRIPTION
"Monitor group for 100Mb/s ports and repeaters
in a system with one or more repeater-units in
multi-segment (post-RFC 1516) version of the MIB
module. Systems which support Counter64 should
also implement snmpRptrGrpMonitor100w64."
::= { snmpRptrModObjGrps 7 }
snmpRptrGrpMonitor100w64 OBJECT-GROUP
OBJECTS { rptrMonitorPortHCReadableOctets,
rptrMonHCTotalOctets }
STATUS current
DESCRIPTION
"Monitor group for 100Mb/s ports and repeaters in a
system with one or more repeater-units and support
for Counter64."
::= { snmpRptrModObjGrps 8 }
snmpRptrGrpAddrTrack OBJECT-GROUP
OBJECTS { rptrAddrTrackGroupIndex,
rptrAddrTrackPortIndex,
rptrAddrTrackSourceAddrChanges,
rptrAddrTrackNewLastSrcAddress,
rptrAddrTrackCapacity }
STATUS current
DESCRIPTION
"Passive address tracking group for post-RFC 1516
version of the MIB module."
<span class="grey">de Graaf, et. al. Standards Track [Page 70]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-71" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
::= { snmpRptrModObjGrps 9 }
snmpRptrGrpExtAddrTrack OBJECT-GROUP
OBJECTS { rptrExtAddrTrackMacIndex,
rptrExtAddrTrackSourceAddress }
STATUS current
DESCRIPTION
"Extended passive address tracking group for
a system with one or more repeater-units in
post-RFC 1516 version of the MIB module."
::= { snmpRptrModObjGrps 10 }
snmpRptrGrpRptrAddrSearch OBJECT-GROUP
OBJECTS { rptrAddrSearchLock,
rptrAddrSearchStatus,
rptrAddrSearchAddress,
rptrAddrSearchState,
rptrAddrSearchGroup,
rptrAddrSearchPort,
rptrAddrSearchOwner }
STATUS current
DESCRIPTION
"Active MAC address search group and topology
mapping support for repeaters."
::= { snmpRptrModObjGrps 11 }
snmpRptrGrpTopNPort OBJECT-GROUP
OBJECTS { rptrTopNPortControlIndex,
rptrTopNPortRepeaterId,
rptrTopNPortRateBase,
rptrTopNPortTimeRemaining,
rptrTopNPortDuration,
rptrTopNPortRequestedSize,
rptrTopNPortGrantedSize,
rptrTopNPortStartTime,
rptrTopNPortOwner,
rptrTopNPortRowStatus,
rptrTopNPortIndex,
rptrTopNPortGroupIndex,
rptrTopNPortPortIndex,
rptrTopNPortRate }
STATUS current
DESCRIPTION
"Top `N' group for repeater ports."
::= { snmpRptrModObjGrps 12 }
-- Compliances
<span class="grey">de Graaf, et. al. Standards Track [Page 71]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-72" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
snmpRptrModComplRFC1368 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Compliance for <a href="./rfc1368">RFC 1368</a>.
NOTE: this module compliance is OBSOLETE and
replaced by snmpRptrModComplRFC1516."
MODULE -- this module
MANDATORY-GROUPS { snmpRptrGrpBasic1516 }
GROUP snmpRptrGrpMonitor1516
DESCRIPTION
"Implementation of this optional group is
recommended for systems which have the
instrumentation to do performance monitoring."
GROUP snmpRptrGrpAddrTrack1368
DESCRIPTION
"Implementation of this group is
recommended for systems which have
the necessary instrumentation."
::= { snmpRptrModCompls 1 }
snmpRptrModComplRFC1516 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"********* THIS COMPLIANCE IS DEPRECATED **********
Compliance for <a href="./rfc1516">RFC 1516</a> and for backwards
compatibility with single-repeater,
10Mb/s-only implementations."
MODULE -- this module
MANDATORY-GROUPS { snmpRptrGrpBasic1516 }
GROUP snmpRptrGrpMonitor1516
DESCRIPTION
"Implementation of this optional group is
recommended for systems which have the
instrumentation to do performance monitoring."
GROUP snmpRptrGrpAddrTrack1516
DESCRIPTION
"Implementation of this group is
recommended for systems which have
the necessary instrumentation."
<span class="grey">de Graaf, et. al. Standards Track [Page 72]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-73" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
::= { snmpRptrModCompls 2 }
snmpRptrModCompl MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance for the multi-segment version of the
MIB module for a system with one or more
repeater-units."
MODULE -- this module
MANDATORY-GROUPS { snmpRptrGrpBasic,
snmpRptrGrpMonitor,
snmpRptrGrpAddrTrack }
GROUP snmpRptrGrpMonitor100
DESCRIPTION
"Implementation of this group is
mandatory for managed systems which
contain 100Mb/s repeaters."
GROUP snmpRptrGrpMonitor100w64
DESCRIPTION
"Implementation of this group is
mandatory for managed systems which
contain 100Mb/s repeaters and which
can support Counter64."
GROUP snmpRptrGrpExtAddrTrack
DESCRIPTION
"Implementation of this group is
recommended for systems which have
the necessary instrumentation to track
MAC addresses of multiple DTEs attached
to a single repeater port."
GROUP snmpRptrGrpRptrAddrSearch
DESCRIPTION
"Implementation of this group is
recommended for systems which allow
read-write access and which have
the necessary instrumentation to
search all incoming data streams
for a particular MAC address."
GROUP snmpRptrGrpTopNPort
DESCRIPTION
"Implementation of this group is
recommended for systems which have
<span class="grey">de Graaf, et. al. Standards Track [Page 73]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-74" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
the necessary resources to support
TopN statistics reporting."
::= { snmpRptrModCompls 3 }
END
<span class="grey">de Graaf, et. al. Standards Track [Page 74]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-75" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
<span class="h2"><a class="selflink" id="section-4" href="#section-4">4</a>. Topology Mapping</span>
The network mapping algorithm presented below takes information
available from network devices such as repeaters, bridges, and
switches, and creates a representation of the physical topology of
the network.
Networking devices connect to the network via one or more ports.
Through these ports, the device is capable of hearing network packets
sent by other devices. By looking the source address in the packet,
and identifying which port the packet was heard on, the device can
provide information to a Network Management System about the location
of an address in the network, relative to that device. For devices
such as bridges and switches, the association of address to port can
be retrieved via the forwarding data base part of the Bridge MIB.
For repeaters, the rptrAddrSearchTable may be used to perform the
association.
Given this information, it would be possible for the NMS to create a
topology of the network which represents the physical relationships
of the devices in the networks. The following is an example of how
this might be done:
Assume the network:
=============================
| | |
| | |
d1 d4 d7
/ \ |
/ \ |
d2 d3 d5
|
|
d6
The discovery process would first determine the existence of the
network devices and nodes in the network. In the above example, the
network devices discovered would be:
d1,d2,d3,d4,d5,d6,d7
From this list of discovered devices, select (arbitrarily or via some
heuristic) a device as the starting point. From that device,
determine where all other devices are located in the network with
respect to the selected device.
<span class="grey">de Graaf, et. al. Standards Track [Page 75]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-76" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
For example, if d1 is the selected device, the network in relation to
d1 would look like:
d1
/ | \
/ | \
d2 d3 d4,d5,d6,d7
So d1 sees d2 on one port, d3 on another port, and d4, d5, and d6 on
the third port. In other words, using the rptrAddrSearchTable (if d1
is a repeater) or the Forwarding Database (if it is a bridge or a
switch), d1 has located d2 on one port, d1 has located d3 on another
port, and finally, d1 has located d4, d5, d6, and d7 on yet another
port.
After the first step of the algorithm is accomplished, the next and
final step is a recursive one. Go to each of these temporary
'segments' (e.g., the segment connecting d1 and d2, or the segment
connecting d1 and d3, or the segment connecting d1, d4, d5, d6, and
d7) and determine which of these devices really belongs in that
segment.
As new segments are created due to this process, the recursive
algorithm visits them, and performs the exact same process.
In the example, the segments connecting d1 and d2, and connecting d1
and d3, require no further scrutiny, since there are only two nodes
in those segments. However, the segment connecting d1, d4, d5, d6,
and d7 may prove to be one or more segments, so we will investigate
it.
The purpose of this step is to determine which devices are really
connected to this segment, and which are actually connected
downstream. This is done by giving each of the child devices in the
segment (d4, d5, d6, and d7) a chance to eliminate each of the others
from the segment.
A device eliminates another device by showing that it hears the
parent device (in this case, d1) on one port, and the other device on
another port (different from the port on which it heard the parent).
If this is true, then it must mean that that device is _between_ the
parent device and the device which is being eliminated.
<span class="grey">de Graaf, et. al. Standards Track [Page 76]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-77" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
In the example, we can see that device d4 can eliminate both d5 and
d6, , but nobody can eliminate d4 and d7, because everybody hears
them on the same port that they hear the parent device (d1). So the
resulting topology looks like:
d1
/ | \
/ | \
d2 d3 d4,d7
|
|
d5,d6
Next the algorithm visits the next segment, which is the one
connecting d4, d5, and d6. Using the process stated above, d5 can
eliminate d6, since it hears d4 on a different port from where it
hears d6. Finally, the topology looks like:
d1
/ | \
/ | \
d2 d3 d4,d7
|
|
d5
|
|
d6
This is actually the topology shown at the beginning of the
description.
With this information about how the network devices are connected, it
is a relatively simple extension to then place nodes such as
workstations and PCs in the network. This can be done by placing the
node into a segment, then allowing the network devices to show that
the node is really not part of that segment.
This elimination can be done because the devices know what port
connects them to the segment on which the node is temporarily placed.
If they actually hear the node on a different port than that which
connects the device to the segment, then the node must be downstream,
and so it is moved onto the downstream segment. Then that segment is
evaluated, and so forth. Eventually, no device can show that the
node is connected downstream, and so it must be attached to that
segment.
<span class="grey">de Graaf, et. al. Standards Track [Page 77]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-78" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
For example, assume the network:
=============================
| | |
| | |
d1 d4 d7
/ \ |
/ \ |
d2 d3 d5
| |
| |
e1 d6
In this network, we are trying to place e1 where it belongs. We
begin by placing it arbitrarily into a segment:
==================================
| | | |
| | | |
e1 d1 d4 d7
/ \ |
/ \ |
d2 d3 d5
|
|
d6
In the above case, we would give d1, d4, and d7 a chance to show that
e1 is not really on that segment. d4 and d7 hear e1 on the same port
which connects them to that segment, so they cannot eliminate e1 from
the segment. However, d1 will hear e1 on a different port, so we
move e1 down onto the segment which is connected by that port. This
yields the following:
=============================
| | |
| | |
d1 d4 d7
/ \ |
/ \ |
d2 d3,e1 d5
|
|
d6
<span class="grey">de Graaf, et. al. Standards Track [Page 78]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-79" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
Now we give everyone in that segment (besides that parent device, d1)
a chance to eliminate e1. Only d3 can try, and it succeeds, so we
place e1 on segment which is connected by the port on which d3 heard
e1. There is no segment there (yet), so we create one, and end up
with the following:
=============================
| | |
| | |
d1 d4 d7
/ \ |
/ \ |
d2 d3 d5
| |
| |
e1 d6
which is the correct position.
<span class="h2"><a class="selflink" id="section-5" href="#section-5">5</a>. Acknowledgements</span>
This document was produced by the IETF Hub MIB Working Group, whose
efforts were greatly advanced by the contributions of the following
people:
Chuck Black
John Flick
Jeff Johnson
Leon Leong
Mike Lui
Dave Perkins
Geoff Thompson
Maurice Turcotte
Paul Woodruff
<span class="grey">de Graaf, et. al. Standards Track [Page 79]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-80" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
<span class="h2"><a class="selflink" id="section-6" href="#section-6">6</a>. References</span>
[<a id="ref-1">1</a>] IEEE 802.3/ISO 8802-3 Information processing systems -
Local area networks - Part 3: Carrier sense multiple
access with collision detection (CSMA/CD) access method
and physical layer specifications, 1993.
[<a id="ref-2">2</a>] IEEE 802.3u-1995, "MAC Parameters, Physical Layer, Medium
Attachment Units and Repeater for 100 Mb/s Operation,
Type 100BASE-T," Sections <a href="#section-21">21</a> through <a href="#section-29">29</a>, Supplement to
IEEE Std 802.3, October 26, 1995.
[<a id="ref-3">3</a>] IEEE 802.3u-1995, "10 & 100 Mb/s Management," <a href="#section-30">Section 30</a>,
Supplement to IEEE Std 802.3, October 26, 1995.
[<a id="ref-4">4</a>] de Graaf, K., D. Romascanu, D. McMaster, K. McCloghrie,
and S. Roberts, "Definitions of Managed Objects for IEEE
802.3 Medium Attachment Units (MAUs)", Work in Progress.
[<a id="ref-5">5</a>] McCloghrie, K., and M. Rose, Editors, "Management
Information Base for Network Management of TCP/IP-based
internets: MIB-II", STD 17, <a href="./rfc1213">RFC 1213</a>, Hughes LAN Systems,
Performance Systems International, March 1991.
[<a id="ref-6">6</a>] SNMPv2 Working Group, J. Case, K. McCloghrie, M. Rose,
and S. Waldbusser, "Structure of Management Information
for version 2 of the Simple Network Management Protocol
(SNMPv2)", <a href="./rfc1902">RFC 1902</a>, January 1996.
[<a id="ref-7">7</a>] SNMPv2 Working Group, J. Case, K. McCloghrie, M. Rose,
and S. Waldbusser, "Textual Conventions for version 2 of
the Simple Network Management Protocol (SNMPv2)", <a href="./rfc1903">RFC</a>
<a href="./rfc1903">1903</a>, January 1996.
[<a id="ref-8">8</a>] SNMPv2 Working Group, J. Case, K. McCloghrie, M. Rose,
and S. Waldbusser, "Conformance Statements for version 2
of the Simple Network Management Protocol (SNMPv2)", <a href="./rfc1904">RFC</a>
<a href="./rfc1904">1904</a>, January 1996.
[<a id="ref-9">9</a>] SNMPv2 Working Group, J. Case, K. McCloghrie, M. Rose,
and S. Waldbusser, "Protocol Operations for version 2 of
the Simple Network Management Protocol (SNMPv2)", <a href="./rfc1905">RFC</a>
<a href="./rfc1905">1905</a>, January 1996.
<span class="grey">de Graaf, et. al. Standards Track [Page 80]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-81" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
[<a id="ref-10">10</a>] Case, J., M. Fedor, M. Schoffstall, and J. Davin, "Simple
Network Management Protocol", STD 15, <a href="./rfc1157">RFC 1157</a>, SNMP
Research, Performance Systems International, MIT Laboratory
for Computer Science, May 1990.
[<a id="ref-11">11</a>] McMaster, D., and K. McCloghrie, "Definitions of Managed
Objects for IEEE 802.3 Repeater Devices", <a href="./rfc1516">RFC 1516</a>,
September 1993.
[<a id="ref-12">12</a>] McAnally, G., D. Gilbert, and J. Flick, "Conditional
Grant of Rights to Specific Hewlett-Packard Patents In
Conjunction With the Internet Engineering Task Force's
Internet-Standard Network Management Framework", <a href="./rfc1988">RFC 1988</a>,
August 1996.
[<a id="ref-13">13</a>] Hewlett-Packard Company, US Patents 5,293,635 and
5,421,024.
[<a id="ref-14">14</a>] McCloghrie, K., and F. Kastenholz, "Evolution of the
Interfaces Group of MIB-II", <a href="./rfc1573">RFC 1573</a>, January 1994.
<span class="h2"><a class="selflink" id="section-7" href="#section-7">7</a>. Security Considerations</span>
Security issues are not discussed in this memo.
<span class="h2"><a class="selflink" id="section-8" href="#section-8">8</a>. Authors' Addresses</span>
Kathryn de Graaf
3Com Corporation
118 Turnpike Rd.
Southborough, MA 01772 USA
Phone: (508)229-1627
Fax: (508)490-5882
EMail: kdegraaf@isd.3com.com
Dan Romascanu
Madge Networks (Israel) Ltd.
Atidim Technology Park, Bldg. 3
Tel Aviv 61131, Israel
Phone: 972-3-6458414, 6458458
Fax: 972-3-6487146
EMail: dromasca@madge.com
<span class="grey">de Graaf, et. al. Standards Track [Page 81]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-82" ></span>
<span class="grey"><a href="./rfc2108">RFC 2108</a> 802.3 Repeater MIB using SMIv2 February 1997</span>
Donna McMaster
Cisco Systems Inc.
170 West Tasman Drive
San Jose, CA 95134
Phone: (408) 526-5260
EMail: mcmaster@cisco.com
Keith McCloghrie
Cisco Systems Inc.
170 West Tasman Drive
San Jose, CA 95134
Phone: (408) 526-5260
EMail: kzm@cisco.com
de Graaf, et. al. Standards Track [Page 82]
</pre>
|