1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2876 2877 2878 2879 2880 2881 2882 2883 2884 2885 2886 2887 2888 2889 2890 2891 2892 2893 2894 2895 2896 2897 2898 2899 2900 2901 2902 2903 2904 2905 2906 2907 2908 2909 2910 2911 2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923 2924 2925 2926 2927 2928 2929 2930 2931 2932 2933 2934 2935 2936 2937 2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981 2982 2983 2984 2985 2986 2987 2988 2989 2990 2991 2992 2993 2994 2995 2996 2997 2998 2999 3000 3001 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3013 3014 3015 3016 3017 3018 3019 3020 3021 3022 3023 3024 3025 3026 3027 3028 3029 3030 3031 3032 3033 3034 3035 3036 3037 3038 3039 3040 3041 3042 3043 3044 3045 3046 3047 3048 3049 3050 3051 3052 3053 3054 3055 3056 3057 3058 3059 3060 3061 3062 3063 3064 3065 3066 3067 3068 3069 3070 3071 3072 3073 3074 3075 3076 3077
|
<pre>Network Working Group N. Brownlee
Request for Comments: 2720 The University of Auckland
Obsoletes: <a href="./rfc2064">2064</a> October 1999
Category: Standards Track
<span class="h1">Traffic Flow Measurement: Meter MIB</span>
Status of this Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
Copyright (C) The Internet Society (1999). All Rights Reserved.
Abstract
The RTFM Traffic Measurement Architecture provides a general
framework for describing and measuring network traffic flows. Flows
are defined in terms of their Address Attribute values and measured
by a 'Traffic Meter'.
This document defines a Management Information Base (MIB) for use in
controlling an RTFM Traffic Meter, in particular for specifying the
flows to be measured. It also provides an efficient mechanism for
retrieving flow data from the meter using SNMP. Security issues
concerning the operation of traffic meters are summarised.
Table of Contents
<a href="#section-1">1</a> Introduction . . . . . . . . . . . . . . . . . . . . . . . . . <a href="#page-2">2</a>
<a href="#section-2">2</a> The SNMP Management Framework . . . . . . . . . . . . . . . . <a href="#page-2">2</a>
<a href="#section-3">3</a> Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . <a href="#page-3">3</a>
<a href="#section-3.1">3.1</a> Scope of Definitions, Textual Conventions . . . . . . . . . <a href="#page-4">4</a>
<a href="#section-3.2">3.2</a> Usage of the MIB variables . . . . . . . . . . . . . . . . <a href="#page-4">4</a>
<a href="#section-4">4</a> Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . <a href="#page-6">6</a>
<a href="#section-5">5</a> Security Considerations . . . . . . . . . . . . . . . . . . . . <a href="#page-46">46</a>
<a href="#section-5.1">5.1</a> SNMP Concerns . . . . . . . . . . . . . . . . . . . . . . <a href="#page-46">46</a>
<a href="#section-5.2">5.2</a> Traffic Meter Concerns . . . . . . . . . . . . . . . . . . <a href="#page-46">46</a>
<a href="#section-6">6</a> IANA Considerations . . . . . . . . . . . . . . . . . . . . . . <a href="#page-48">48</a>
<a href="#section-7">7</a> <a href="#appendix-A">Appendix A</a>: Changes Introduced Since <a href="./rfc2064">RFC 2064</a> . . . . . . . . . <a href="#page-49">49</a>
<a href="#section-8">8</a> Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . <a href="#page-50">50</a>
<a href="#section-9">9</a> Intellectual Property Notice . . . . . . . . . . . . . . . . . <a href="#page-50">50</a>
<span class="grey">Brownlee Standards Track [Page 1]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-2" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
<a href="#section-10">10</a> References . . . . . . . . . . . . . . . . . . . . . . . . . . <a href="#page-50">50</a>
<a href="#section-11">11</a> Author's Address . . . . . . . . . . . . . . . . . . . . . . . <a href="#page-53">53</a>
<a href="#section-12">12</a> Full Copyright Statement . . . . . . . . . . . . . . . . . . . <a href="#page-54">54</a>
<span class="h2"><a class="selflink" id="section-1" href="#section-1">1</a> Introduction</span>
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in the Internet community.
In particular, it describes objects for managing and collecting data
from network Realtime Traffic Flow Meters, as described in [RTFM-
ARC].
The MIB is 'basic' in the sense that it provides more than enough
information for everyday traffic measurment. Furthermore, it can be
easily extended by adding new attributes as required. The RTFM
Working group is actively pursuing the development of the meter in
this way.
<span class="h2"><a class="selflink" id="section-2" href="#section-2">2</a> The SNMP Management Framework</span>
The SNMP Management Framework presently consists of five major
components:
- An overall architecture, described in <a href="./rfc2571">RFC 2571</a> [<a href="./rfc2571" title=""An Architecture for Describing SNMP Management Frameworks"">RFC2571</a>].
- Mechanisms for describing and naming objects and events for the
purpose of management. The first version of this Structure of
Management Information (SMI) is called SMIv1 and described in STD
16, <a href="./rfc1155">RFC 1155</a> [<a href="./rfc1155" title=""Structure and Identification of Management Information for TCP/IP-based Internets"">RFC1155</a>], STD 16, <a href="./rfc1212">RFC 1212</a> [<a href="./rfc1212" title=""Concise MIB Definitions"">RFC1212</a>] and <a href="./rfc1215">RFC 1215</a>
[<a href="./rfc1215" title=""A Convention for Defining Traps for use with the SNMP"">RFC1215</a>]. The second version, called SMIv2, is described in STD
58, <a href="./rfc2578">RFC 2578</a> [<a href="./rfc2578" title=""Structure of Management Information Version 2 (SMIv2)"">RFC2578</a>], <a href="./rfc2579">RFC 2579</a> [<a href="./rfc2579" title=""Textual Conventions for SMIv2"">RFC2579</a>] and <a href="./rfc2580">RFC 2580</a> [<a href="./rfc2580" title=""Conformance Statements for SMIv2"">RFC2580</a>].
- Message protocols for transferring management information. The
first version of the SNMP message protocol is called SNMPv1 and
described in STD 15, <a href="./rfc1157">RFC 1157</a> [<a href="./rfc1157" title=""Simple Network Management Protocol"">RFC1157</a>]. A second version of the
SNMP message protocol, which is not an Internet standards track
protocol, is called SNMPv2c and described in <a href="./rfc1901">RFC 1901</a> [<a href="./rfc1901" title=""Introduction to Community-based SNMPv2"">RFC1901</a>] and
<a href="./rfc1906">RFC 1906</a> [<a href="./rfc1906" title=""Transport Mappings for Version 2 of the Simple Network Management Protocol (SNMPv2)"">RFC1906</a>]. The third version of the message protocol is
called SNMPv3 and described in <a href="./rfc1906">RFC 1906</a> [<a href="./rfc1906" title=""Transport Mappings for Version 2 of the Simple Network Management Protocol (SNMPv2)"">RFC1906</a>], <a href="./rfc2572">RFC 2572</a>
[<a href="./rfc2572" title=""Message Processing and Dispatching for the Simple Network Management Protocol (SNMP)"">RFC2572</a>] and <a href="./rfc2574">RFC 2574</a> [<a href="./rfc2574" title=""User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)"">RFC2574</a>].
- Protocol operations for accessing management information. The
first set of protocol operations and associated PDU formats is
described in STD 15, <a href="./rfc1157">RFC 1157</a> [<a href="./rfc1157" title=""Simple Network Management Protocol"">RFC1157</a>]. A second set of protocol
operations and associated PDU formats is described in <a href="./rfc1905">RFC 1905</a>
[<a href="./rfc1905" title=""Protocol Operations for Version 2 of the Simple Network Management Protocol (SNMPv2)"">RFC1905</a>].
<span class="grey">Brownlee Standards Track [Page 2]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-3" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
- A set of fundamental applications described in <a href="./rfc2573">RFC 2573</a> [<a href="./rfc2573" title=""SNMPv3 Applications"">RFC2573</a>]
and the view-based access control mechanism described in <a href="./rfc2575">RFC 2575</a>
[<a href="./rfc2575" title=""View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)"">RFC2575</a>].
A more detailed introduction to the current SNMP Management Framework
can be found in [<a href="./rfc2570" title=""Introduction to Version 3 of the Internet-standard Network Management Framework"">RFC2570</a>].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. Objects in the MIB are
defined using the mechanisms defined in the SMI.
This memo specifies a MIB module that is compliant to the SMIv2. A
MIB conforming to the SMIv1 can be produced through the appropriate
translations. The resulting translated MIB must be semantically
equivalent, except where objects or events are omitted because no
translation is possible (use of Counter64). Some machine readable
information in SMIv2 will be converted into textual descriptions in
SMIv1 during the translation process. However, this loss of machine
readable information is not considered to change the semantics of the
MIB.
<span class="h2"><a class="selflink" id="section-3" href="#section-3">3</a> Overview</span>
Traffic Flow Measurement seeks to provide a well-defined method for
gathering traffic flow information from networks and internetworks.
The background for this is given in "Internet Accounting Background"
[<a href="#ref-ACT-BKG" title=""Internet Accounting Background"">ACT-BKG</a>]. The Realtime Traffic Flow Measurement (rtfm) Working Group
has produced a measurement architecture to achieve this goal; this is
documented in "Traffic Flow Measurement: Architecture" [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>].
The architecture defines three entities:
- METERS, which observe network traffic flows and build up a table of
flow data records for them,
- METER READERS, which collect traffic flow data from meters, and
- MANAGERS, which oversee the operation of meters and meter readers.
This memo defines the SNMP management information for a Traffic Flow
Meter (TFM). Work in this field was begun by the Internet Accounting
Working Group. It has been further developed and expanded by the
Realtime Traffic Flow Measurement Working Group.
<span class="grey">Brownlee Standards Track [Page 3]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-4" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
<span class="h3"><a class="selflink" id="section-3.1" href="#section-3.1">3.1</a> Scope of Definitions, Textual Conventions</span>
All objects defined in this memo are registered in a single subtree
within the mib-2 namespace [MIB-II, <a href="./rfc2578">RFC2578</a>], and are for use in
network devices which may perform a PDU forwarding or monitoring
function. For these devices, this MIB defines a group of objects
with an SMI Network Management MGMT Code [<a href="#ref-ASG-NBR" title=""Assigned Numbers"">ASG-NBR</a>] of 40, i.e.
flowMIB OBJECT IDENTIFIER ::= mib-2 40
as defined below.
The RTFM Meter MIB was first produced and tested using SNMPv1. It
was converted into SNMPv2 following the guidelines in [<a href="./rfc1908" title=""Coexistence between version 1 and version 2 of the Internet-standard Network Management Framework"">RFC1908</a>].
<span class="h3"><a class="selflink" id="section-3.2" href="#section-3.2">3.2</a> Usage of the MIB variables</span>
The MIB is organised in four parts - control, data, rules and
conformance statements.
The rules implement the set of packet-matching actions, as described
in the "Traffic Flow Measurment: Architecture" document [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>].
In addition they provide for BASIC-style subroutines, allowing a
network manager to dramatically reduce the number of rules required
to monitor a large network.
Traffic flows are identified by a set of attributes for each of their
end-points. Attributes include network addresses for each layer of
the network protocol stack, and 'subscriber ids', which may be used
to identify an accountable entity for the flow.
The conformance statements are set out as defined in [<a href="./rfc2580" title=""Conformance Statements for SMIv2"">RFC2580</a>]. They
explain what must be implemented in a meter which claims to conform
to this MIB.
To retrieve flow data one could simply do a linear scan of the flow
table. This would certainly work, but would require a lot of
protocol exchanges. To reduce the overhead in retrieving flow data
the flow table uses a TimeFilter variable, defined as a Textual
Convention in the RMON2 MIB [<a href="#ref-RMON2-MIB" title=""Remote Network Monitoring Management Information Base Version 2 using SMIv2"">RMON2-MIB</a>].
As an alternative method of reading flow data, the MIB provides a
view of the flow table called the flowDataPackageTable. This is
(logically) a four-dimensional array, subscripted by package
selector, RuleSet, activity time and starting flow number. The
package selector is a sequence of bytes which specifies a list of
flow attributes.
<span class="grey">Brownlee Standards Track [Page 4]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-5" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
A data package (as returned by the meter) is a sequence of values for
the attributes specified in its selector, encoded using the Basic
Encoding Rules [<a href="#ref-ASN-BER" title="International Organization for Standardization">ASN-BER</a>]. It allows a meter reader to retrieve all
the attribute values it requires in a single MIB object. This, when
used together with SNMPv2's GetBulk request, allows a meter reader to
scan the flow table and upload a specified set of attribute values
for flows which have changed since the last reading, and which were
created by a specified rule set.
One aspect of data collection which needs emphasis is that all the
MIB variables are set up to allow multiple independent meter readers
to work properly, i.e. the flow table indexes are stateless. An
alternative approach would have been to 'snapshot' the flow table,
which would mean that the meter readers would have to be
synchronized. The stateless approach does mean that two meter
readers will never return exactly the same set of traffic counts, but
over long periods (e.g. 15-minute collections over a day) the
discrepancies are acceptable. If one really needs a snapshot, this
can be achieved by switching to an identical rule set with a
different RuleSet number, hence asynchronous collections may be
regarded as a useful generalisation of synchronised ones.
The control variables are the minimum set required for a meter
reader. Their number has been whittled down as experience has been
gained with the MIB implementation. A few of them are 'general',
i.e. they control the overall behaviour of the meter. These are set
by a single 'master' manager, and no other manager should attempt to
change their values. The decision as to which manager is the '
master' must be made by the network operations personnel responsible;
this MIB does not attempt to define any interaction between managers.
There are three other groups of control variables, arranged into
tables in the same way as in the RMON2 MIB [<a href="#ref-RMON2-MIB" title=""Remote Network Monitoring Management Information Base Version 2 using SMIv2"">RMON2-MIB</a>]. They are used
as follows:
- RULE SET INFO: Before attempting to download a RuleSet, a manager
must create a row in the flowRuleSetInfoTable and set its
flowRuleInfoSize to a value large enough to hold the RuleSet. When
the rule set is ready the manager must set flowRuleInfoRulesReady
to 'true', indicating that the rule set is ready for use (but not
yet 'running').
- METER READER INFO: Any meter reader wishing to collect data
reliably for all flows from a RuleSet should first create a row in
the flowReaderInfoTable with flowReaderRuleSet set to that
RuleSet's index in the flowRuleSetInfoTable. It should write that
row's flowReaderLastTime object each time it starts a collection
<span class="grey">Brownlee Standards Track [Page 5]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-6" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
pass through the flow table. The meter will not recover a flow's
memory until every meter reader holding a row for that flow's
RuleSet has collected the flow's data.
- MANAGER INFO: Any manager wishing to run a RuleSet in the meter
must create a row in the flowManagerInfo table, specifying the
desired RuleSet to run and its corresponding 'standby' RuleSet (if
one is desired). A current RuleSet is 'running' if its
flowManagerRunningStandby value is false(2), similarly a standby
RuleSet is 'running' if flowManagerRunningStandby is true(1).
Times within the meter are in terms of its Uptime, i.e. centiseconds
since the meter started. For meters implemented as self-contained
SNMP agents this will be the same as sysUptime, but this may not be
true for meters implemented as subagents. Managers can read the
meter's Uptime when neccessary (e.g. to set a TimeFilter value) by
setting flowReaderLastTime, then reading its new value.
<span class="h2"><a class="selflink" id="section-4" href="#section-4">4</a> Definitions</span>
FLOW-METER-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Counter32, Counter64, Integer32, mib-2
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus, TimeStamp, TruthValue
FROM SNMPv2-TC
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
ifIndex
FROM IF-MIB
TimeFilter
FROM RMON2-MIB;
flowMIB MODULE-IDENTITY
LAST-UPDATED "9910250000Z" -- October 25, 1999
ORGANIZATION "IETF Realtime Traffic Flow Measurement Working Group"
CONTACT-INFO
"Nevil Brownlee, The University of Auckland
Postal: Information Technology Sytems & Services
The University of Auckland
Private Bag 92-019
Auckland, New Zealand
Phone: +64 9 373 7599 x8941
E-mail: n.brownlee@auckland.ac.nz"
<span class="grey">Brownlee Standards Track [Page 6]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-7" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
DESCRIPTION
"MIB for the RTFM Traffic Flow Meter."
REVISION "9910250000Z"
DESCRIPTION
"Initial Version, published as <a href="./rfc2720">RFC 2720</a>."
REVISION "9908301250Z"
DESCRIPTION
"UTF8OwnerString Textual Convention added, and used to
replace OwnerString. Conceptually the same as OwnerString,
but facilitating internationalisation by using UTF-8
encoding for its characters rather than US-ASCII."
REVISION "9908191010Z"
DESCRIPTION
"Changes to SIZE specification for two variables:
- flowRuleInfoName SIZE specified as (0..127)
- flowRuleIndex SIZE increased to (1..2147483647)"
REVISION "9712230937Z"
DESCRIPTION
"Two further variables deprecated:
- flowRuleInfoRulesReady (use flowRuleInfoStatus intead)
- flowDataStatus (contains no useful information)"
REVISION "9707071715Z"
DESCRIPTION
"Significant changes since <a href="./rfc2064">RFC 2064</a> include:
- flowDataPackageTable added
- flowColumnActivityTable deprecated
- flowManagerCounterWrap deprecated"
REVISION "9603080208Z"
DESCRIPTION
"Initial version of this MIB (<a href="./rfc2064">RFC 2064</a>)"
::= { mib-2 40 }
flowControl OBJECT IDENTIFIER ::= { flowMIB 1 }
flowData OBJECT IDENTIFIER ::= { flowMIB 2 }
flowRules OBJECT IDENTIFIER ::= { flowMIB 3 }
flowMIBConformance OBJECT IDENTIFIER ::= { flowMIB 4 }
-- Textual Conventions
<span class="grey">Brownlee Standards Track [Page 7]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-8" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
UTF8OwnerString ::= TEXTUAL-CONVENTION
DISPLAY-HINT "127t"
STATUS current
DESCRIPTION
"An administratively assigned name for the owner of a
resource, conceptually the same as OwnerString in the RMON
MIB [<a href="#ref-RMON-MIB" title=""Remote Network Monitoring Management Information Base"">RMON-MIB</a>].
To facilitate internationalisation, this name information
is represented using the ISO/IEC IS 10646-1 character set,
encoded as an octet string using the UTF-8 transformation
format described in the UTF-8 standard [<a href="#ref-UTF-8" title=""UTF-8, a transformation format of ISO 10646"">UTF-8</a>]."
SYNTAX OCTET STRING (SIZE (0..127))
PeerType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the type of a PeerAddress (see below). The values
used are from the 'Address Family Numbers' section of the
Assigned Numbers RFC [<a href="#ref-ASG-NBR" title=""Assigned Numbers"">ASG-NBR</a>]. Peer types from other address
families may also be used, provided only that they are
identified by their assigned Address Family numbers."
SYNTAX INTEGER {
ipv4(1),
ipv6(2),
nsap(3),
ipx(11),
appletalk(12),
decnet(13) }
PeerAddress ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the value of a peer address for various network
protocols. Address format depends on the actual protocol,
as indicated below:
IPv4: ipv4(1)
4-octet IpAddress (defined in the SNMPv2 SMI [<a href="./rfc2578" title=""Structure of Management Information Version 2 (SMIv2)"">RFC2578</a>])
IPv6: ipv6(2)
16-octet IpAddress (defined in the
IPv6 Addressing RFC [<a href="#ref-V6-ADDR" title=""IP Version 6 Addressing Architecture"">V6-ADDR</a>])
CLNS: nsap(3)
NsapAddress (defined in the SNMPv2 SMI [<a href="./rfc2578" title=""Structure of Management Information Version 2 (SMIv2)"">RFC2578</a>])
Novell: ipx(11)
<span class="grey">Brownlee Standards Track [Page 8]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-9" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
4-octet Network number,
6-octet Host number (MAC address)
AppleTalk: appletalk(12)
2-octet Network number (sixteen bits),
1-octet Host number (eight bits)
DECnet: decnet(13)
1-octet Area number (in low-order six bits),
2-octet Host number (in low-order ten bits)
"
SYNTAX OCTET STRING (SIZE (3..20))
AdjacentType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the type of an adjacent address. May be a medium
type or (if metering is taking place inside a tunnel) a
PeerType (see above).
The values used for IEEE 802 medium types are from the 'Network
Management Parameters (ifType definitions)' section of the
Assigned Numbers RFC [<a href="#ref-ASG-NBR" title=""Assigned Numbers"">ASG-NBR</a>]. Other medium types may also
be used, provided only that they are identified by their
assigned ifType numbers."
SYNTAX INTEGER {
ip(1),
nsap(3),
ethernet(7), -- ethernet-like [<a href="#ref-ENET-OBJ" title=""Definitions of Managed Objects for the Ethernet-like Interface Types"">ENET-OBJ</a>],
-- includes ethernet-csmacd(6)
tokenring(9),
ipx(11),
appletalk(12),
decnet(13),
fddi(15) }
AdjacentAddress ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the value of an adjacent address. May be a Medium
Access Control (MAC) address or (if metering is taking place
inside a tunnel) a PeerAddress (see above).
MAC Address format depends on the actual medium, as follows:
Ethernet: ethernet(7)
6-octet 802.3 MAC address in 'canonical' order
<span class="grey">Brownlee Standards Track [Page 9]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-10" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
Token Ring: tokenring(9)
6-octet 802.5 MAC address in 'canonical' order
FDDI: fddi(15)
FddiMACLongAddress, i.e. a 6-octet MAC address
in 'canonical' order (defined in [<a href="#ref-FDDI-MIB" title=""FDDI Management Information Base"">FDDI-MIB</a>])
"
SYNTAX OCTET STRING (SIZE (3..20))
TransportType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the type of a TransportAddress (see below). Values
will depend on the actual protocol; for IP they will be those
given in the 'Protocol Numbers' section of the Assigned Numbers
RFC [<a href="#ref-ASG-NBR" title=""Assigned Numbers"">ASG-NBR</a>], including icmp(1), tcp(6) and udp(17)."
SYNTAX Integer32 (1..255)
TransportAddress ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the value of a transport address for various
network protocols. Format as follows:
IP:
2-octet UDP or TCP port number
Other protocols:
2-octet port number
"
SYNTAX OCTET STRING (SIZE (2))
RuleAddress ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the value of an address. Is a superset of
MediumAddress, PeerAddress and TransportAddress."
SYNTAX OCTET STRING (SIZE (2..20))
FlowAttributeNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Uniquely identifies an attribute within a flow data record."
SYNTAX INTEGER {
flowIndex(1),
flowStatus(2),
flowTimeMark(3),
<span class="grey">Brownlee Standards Track [Page 10]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-11" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
sourceInterface(4),
sourceAdjacentType(5),
sourceAdjacentAddress(6),
sourceAdjacentMask(7),
sourcePeerType(8),
sourcePeerAddress(9),
sourcePeerMask(10),
sourceTransType(11),
sourceTransAddress(12),
sourceTransMask(13),
destInterface(14),
destAdjacentType(15),
destAdjacentAddress(16),
destAdjacentMask(17),
destPeerType(18),
destPeerAddress(19),
destPeerMask(20),
destTransType(21),
destTransAddress(22),
destTransMask(23),
pduScale(24),
octetScale(25),
ruleSet(26),
toOctets(27), -- Source-to-Dest
toPDUs(28),
fromOctets(29), -- Dest-to-Source
fromPDUs(30),
firstTime(31), -- Activity times
lastActiveTime(32),
sourceSubscriberID(33), -- Subscriber ID
destSubscriberID(34),
sessionID(35),
sourceClass(36), -- Computed attributes
destClass(37),
flowClass(38),
sourceKind(39),
destKind(40),
flowKind(41) }
RuleAttributeNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Uniquely identifies an attribute which may be tested in
<span class="grey">Brownlee Standards Track [Page 11]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-12" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
a rule. These include attributes whose values come directly
from (or are computed from) the flow's packets, and the five
'meter' variables used to hold an Attribute Number."
SYNTAX INTEGER {
null(0),
sourceInterface(4), -- Source Address
sourceAdjacentType(5),
sourceAdjacentAddress(6),
sourcePeerType(8),
sourcePeerAddress(9),
sourceTransType(11),
sourceTransAddress(12),
destInterface(14), -- Dest Address
destAdjacentType(15),
destAdjacentAddress(16),
destPeerType(18),
destPeerAddress(19),
destTransType(21),
destTransAddress(22),
sourceSubscriberID(33), -- Subscriber ID
destSubscriberID(34),
sessionID(35),
sourceClass(36), -- Computed attributes
destClass(37),
flowClass(38),
sourceKind(39),
destKind(40),
flowKind(41),
matchingStoD(50), -- Packet matching
v1(51), -- Meter variables
v2(52),
v3(53),
v4(54),
v5(55) }
ActionNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Uniquely identifies the action of a rule, i.e. the Pattern
Matching Engine's opcode number. Details of the opcodes
are given in the 'Traffic Flow Measurement: Architecture'
document [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>]."
SYNTAX INTEGER {
<span class="grey">Brownlee Standards Track [Page 12]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-13" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
ignore(1),
noMatch(2),
count(3),
countPkt(4),
return(5),
gosub(6),
gosubAct(7),
assign(8),
assignAct(9),
goto(10),
gotoAct(11),
pushRuleTo(12),
pushRuleToAct(13),
pushPktTo(14),
pushPktToAct(15),
popTo(16),
popToAct(17) }
--
-- Control Group: RuleSet Info Table
--
flowRuleSetInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowRuleSetInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An array of information about the RuleSets held in the
meter.
Any manager may configure a new RuleSet for the meter by
creating a row in this table with status active(1), and setting
values for all the objects in its rules. At this stage the new
RuleSet is available but not 'running', i.e. it is not being
used by the meter to produce entries in the flow table.
To actually 'run' a RuleSet a manager must create a row in
the flowManagerInfoTable, set it's flowManagerStatus to
active(1), and set either its CurrentRuleSet or StandbyRuleSet
to point to the RuleSet to be run.
Once a RuleSet is running a manager may not change any of the
objects within the RuleSet itself. Any attempt to do so should
result in a notWritable(17) SNMP error-status for such objects.
A manager may stop a RuleSet running by removing all
references to it in the flowManagerInfoTable (i.e. by setting
CurrentRuleSet and StandbyRuleSet values to 0). This provides
<span class="grey">Brownlee Standards Track [Page 13]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-14" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
a way to stop RuleSets left running if a manager fails.
For example, when a manager is started, it could search the
meter's flowManager table and stop all RuleSets having a
specified value of flowRuleInfoOwner.
To prevent a manager from interfering with variables belonging
to another manager, the meter should use MIB views [<a href="./rfc2575" title=""View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)"">RFC2575</a>] so
as to limit each manager's access to the meter's variables,
effectively dividing the single meter into several virtual
meters, one for each independent manager."
::= { flowControl 1 }
flowRuleSetInfoEntry OBJECT-TYPE
SYNTAX FlowRuleSetInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular RuleSet."
INDEX { flowRuleInfoIndex }
::= { flowRuleSetInfoTable 1 }
FlowRuleSetInfoEntry ::= SEQUENCE {
flowRuleInfoIndex Integer32,
flowRuleInfoSize Integer32,
flowRuleInfoOwner UTF8OwnerString,
flowRuleInfoTimeStamp TimeStamp,
flowRuleInfoStatus RowStatus,
flowRuleInfoName OCTET STRING,
flowRuleInfoRulesReady TruthValue,
flowRuleInfoFlowRecords Integer32
}
flowRuleInfoIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index which selects an entry in the flowRuleSetInfoTable.
Each such entry contains control information for a particular
RuleSet which the meter may run."
::= { flowRuleSetInfoEntry 1 }
flowRuleInfoSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of rules in this RuleSet. Setting this variable will
<span class="grey">Brownlee Standards Track [Page 14]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-15" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
cause the meter to allocate space for these rules."
::= { flowRuleSetInfoEntry 2 }
flowRuleInfoOwner OBJECT-TYPE
SYNTAX UTF8OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Identifies the manager which 'owns' this RuleSet. A manager
must set this variable when creating a row in this table."
::= { flowRuleSetInfoEntry 3 }
flowRuleInfoTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time this row's associated RuleSet was last changed."
::= { flowRuleSetInfoEntry 4 }
flowRuleInfoStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this flowRuleSetInfoEntry. If this value is
not active(1) the meter must not attempt to use the row's
associated RuleSet. Once its value has been set to active(1)
a manager may not change any of the other variables in the
row, nor the contents of the associated RuleSet. Any attempt
to do so should result in a notWritable(17) SNMP error-status
for such variables or objects.
To download a RuleSet, a manger could:
- Locate an open slot in the RuleSetInfoTable.
- Create a RuleSetInfoEntry by setting the status for this
open slot to createAndWait(5).
- Set flowRuleInfoSize and flowRuleInfoName as required.
- Download the rules into the row's rule table.
- Set flowRuleInfoStatus to active(1).
The RuleSet would then be ready to run. The manager is not
allowed to change the value of flowRuleInfoStatus from
active(1) if the associated RuleSet is being referenced by any
of the entries in the flowManagerInfoTable.
Setting RuleInfoStatus to destroy(6) destroys the associated
RuleSet together with any flow data collected by it."
<span class="grey">Brownlee Standards Track [Page 15]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-16" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
::= { flowRuleSetInfoEntry 5 }
flowRuleInfoName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..127))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An alphanumeric identifier used by managers and readers to
identify a RuleSet. For example, a manager wishing to run a
RuleSet named WWW-FLOWS could search the flowRuleSetInfoTable
to see whether the WWW-FLOWS RuleSet is already available on
the meter.
Note that references to RuleSets in the flowManagerInfoTable
use indexes for their flowRuleSetInfoTable entries. These may
be different each time the RuleSet is loaded into a meter."
::= { flowRuleSetInfoEntry 6 }
flowRuleInfoRulesReady OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Indicates whether the rules for this row's associated RuleSet
are ready for use. The meter will refuse to 'run' the RuleSet
unless this variable has been set to true(1).
While RulesReady is false(2), the manager may modify the
RuleSet, for example by downloading rules into it."
::= { flowRuleSetInfoEntry 7 }
flowRuleInfoFlowRecords OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of entries in the flow table for this RuleSet.
These may be current (waiting for collection by one or more
meter readers) or idle (waiting for the meter to recover
their memory)."
::= { flowRuleSetInfoEntry 8 }
--
-- Control Group: Interface Info Table
--
flowInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowInterfaceEntry
MAX-ACCESS not-accessible
<span class="grey">Brownlee Standards Track [Page 16]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-17" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
STATUS current
DESCRIPTION
"An array of information specific to each meter interface."
::= { flowControl 2 }
flowInterfaceEntry OBJECT-TYPE
SYNTAX FlowInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular interface."
INDEX { ifIndex }
::= { flowInterfaceTable 1 }
FlowInterfaceEntry ::= SEQUENCE {
flowInterfaceSampleRate Integer32,
flowInterfaceLostPackets Counter32
}
flowInterfaceSampleRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The parameter N for statistical counting on this interface.
Set to N to count 1/Nth of the packets appearing at this
interface. A sampling rate of 1 counts all packets.
A sampling rate of 0 results in the interface being ignored
by the meter.
A meter should choose its own algorithm to introduce variance
into the sampling so that exactly every Nth packet is counted.
The IPPM Working Group's RFC 'Framework for IP Performance
Metrics' [<a href="#ref-IPPM-FRM" title=""Framework for IP Performance Metrics"">IPPM-FRM</a>] explains why this should be done, and sets
out an algorithm for doing it."
DEFVAL { 1 }
::= { flowInterfaceEntry 1 }
flowInterfaceLostPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets the meter has lost for this interface.
Such losses may occur because the meter has been unable to
keep up with the traffic volume."
::= { flowInterfaceEntry 2 }
<span class="grey">Brownlee Standards Track [Page 17]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-18" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
--
-- Control Group: Meter Reader Info Table
--
-- Any meter reader wishing to collect data reliably for flows
-- should first create a row in this table. It should write that
-- row's flowReaderLastTime object each time it starts a collection
-- pass through the flow table.
-- If a meter reader (MR) does not create a row in this table, e.g.
-- because its MIB view [<a href="./rfc2575" title=""View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)"">RFC2575</a>] did not allow MR create access to
-- flowReaderStatus, collection can still proceed but the meter will
-- not be aware of meter reader MR. This could lead the meter to
-- recover flows before they have been collected by MR.
flowReaderInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowReaderInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An array of information about meter readers which have
registered their intent to collect flow data from this meter."
::= { flowControl 3 }
flowReaderInfoEntry OBJECT-TYPE
SYNTAX FlowReaderInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular meter reader."
INDEX { flowReaderIndex }
::= { flowReaderInfoTable 1 }
FlowReaderInfoEntry ::= SEQUENCE {
flowReaderIndex Integer32,
flowReaderTimeout Integer32,
flowReaderOwner UTF8OwnerString,
flowReaderLastTime TimeStamp,
flowReaderPreviousTime TimeStamp,
flowReaderStatus RowStatus,
flowReaderRuleSet Integer32
}
flowReaderIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
<span class="grey">Brownlee Standards Track [Page 18]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-19" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
"An index which selects an entry in the flowReaderInfoTable."
::= { flowReaderInfoEntry 1 }
flowReaderTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the maximum time (in seconds) between flow data
collections for this meter reader. If this time elapses
without a collection, the meter should assume that this meter
reader has stopped collecting, and delete this row from the
table. A value of zero indicates that this row should not be
timed out."
::= { flowReaderInfoEntry 2 }
flowReaderOwner OBJECT-TYPE
SYNTAX UTF8OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Identifies the meter reader which created this row."
::= { flowReaderInfoEntry 3 }
flowReaderLastTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time this meter reader began its most recent data collection.
This variable should be written by a meter reader as its first
step in reading flow data. The meter will set this LastTime
value to its current Uptime, and set its PreviousTime value
(below) to the old LastTime. This allows the meter to
recover flows which have been inactive since PreviousTime,
for these have been collected at least once.
If the meter reader fails to write flowLastReadTime, collection
may still proceed but the meter may not be able to recover
inactive flows until the flowReaderTimeout has been reached
for this entry."
::= { flowReaderInfoEntry 4 }
flowReaderPreviousTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
<span class="grey">Brownlee Standards Track [Page 19]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-20" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
DESCRIPTION
"Time this meter reader began the collection before last."
::= { flowReaderInfoEntry 5 }
flowReaderStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this FlowReaderInfoEntry. A value of active(1)
implies that the associated reader should be collecting data
from the meter. Once this variable has been set to active(1)
a manager may only change this row's flowReaderLastTime and
flowReaderTimeout variables."
::= { flowReaderInfoEntry 6 }
flowReaderRuleSet OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An index to the array of RuleSets. Specifies a set of rules
of interest to this meter reader. The reader will attempt to
collect any data generated by the meter for this RuleSet, and
the meter will not recover the memory of any of the RuleSet's
flows until this collection has taken place. Note that a
reader may have entries in this table for several RuleSets."
::= { flowReaderInfoEntry 7 }
--
-- Control Group: Manager Info Table
--
-- Any manager wishing to run a RuleSet must create a row in this
-- table. Once it has a table row, the manager may set the control
-- variables in its row so as to cause the meter to run any valid
-- RuleSet held by the meter.
-- A single manager may run several RuleSets; it must create a row
-- in this table for each of them. In short, each row of this table
-- describes (and controls) a 'task' which the meter is executing.
flowManagerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowManagerInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An array of information about managers which have
<span class="grey">Brownlee Standards Track [Page 20]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-21" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
registered their intent to run RuleSets on this meter."
::= { flowControl 4 }
flowManagerInfoEntry OBJECT-TYPE
SYNTAX FlowManagerInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular meter 'task.' By creating
an entry in this table and activating it, a manager requests
that the meter 'run' the indicated RuleSet.
The entry also specifies a HighWaterMark and a StandbyRuleSet.
If the meter's flow table usage exceeds this task's
HighWaterMark the meter will stop running the task's
CurrentRuleSet and switch to its StandbyRuleSet.
If the value of the task's StandbyRuleSet is 0 when its
HighWaterMark is exceeded, the meter simply stops running the
task's CurrentRuleSet. By careful selection of HighWaterMarks
for the various tasks a manager can ensure that the most
critical RuleSets are the last to stop running as the number
of flows increases.
When a manager has determined that the demand for flow table
space has abated, it may cause the task to switch back to its
CurrentRuleSet by setting its flowManagerRunningStandby
variable to false(2)."
INDEX { flowManagerIndex }
::= { flowManagerInfoTable 1 }
FlowManagerInfoEntry ::= SEQUENCE {
flowManagerIndex Integer32,
flowManagerCurrentRuleSet Integer32,
flowManagerStandbyRuleSet Integer32,
flowManagerHighWaterMark Integer32,
flowManagerCounterWrap INTEGER,
flowManagerOwner UTF8OwnerString,
flowManagerTimeStamp TimeStamp,
flowManagerStatus RowStatus,
flowManagerRunningStandby TruthValue
}
flowManagerIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
<span class="grey">Brownlee Standards Track [Page 21]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-22" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
"An index which selects an entry in the flowManagerInfoTable."
::= { flowManagerInfoEntry 1 }
flowManagerCurrentRuleSet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index to the array of RuleSets. Specifies which set of
rules is the 'current' one for this task. The meter will
be 'running' the current RuleSet if this row's
flowManagerRunningStandby value is false(2).
When the manager sets this variable the meter will stop using
the task's old current RuleSet and start using the new one.
Specifying RuleSet 0 (the empty set) stops flow measurement
for this task."
::= { flowManagerInfoEntry 2 }
flowManagerStandbyRuleSet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index to the array of RuleSets. After reaching HighWaterMark
(see below) the manager will switch to using the task's
StandbyRuleSet in place of its CurrentRuleSet. For this to be
effective the designated StandbyRuleSet should have a coarser
reporting granularity then the CurrentRuleSet. The manager may
also need to decrease the meter reading interval so that the
meter can recover flows measured by this task's CurrentRuleSet."
DEFVAL { 0 } -- No standby
::= { flowManagerInfoEntry 3 }
flowManagerHighWaterMark OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A value expressed as a percentage, interpreted by the meter
as an indication of how full the flow table should be before
it should switch to the standby RuleSet (if one has been
specified) for this task. Values of 0% or 100% disable the
checking represented by this variable."
::= { flowManagerInfoEntry 4 }
flowManagerCounterWrap OBJECT-TYPE
SYNTAX INTEGER { wrap(1), scale(2) }
<span class="grey">Brownlee Standards Track [Page 22]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-23" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Specifies whether PDU and octet counters should wrap when
they reach the top of their range (normal behaviour for
Counter64 objects), or whether their scale factors should
be used instead. The combination of counter and scale
factor allows counts to be returned as non-negative binary
floating point numbers, with 64-bit mantissas and 8-bit
exponents."
DEFVAL { wrap }
::= { flowManagerInfoEntry 5 }
flowManagerOwner OBJECT-TYPE
SYNTAX UTF8OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Identifies the manager which created this row."
::= { flowManagerInfoEntry 6 }
flowManagerTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time this row was last changed by its manager."
::= { flowManagerInfoEntry 7 }
flowManagerStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this row in the flowManagerInfoTable. A value
of active(1) implies that this task may be activated, by
setting its CurrentRuleSet and StandbyRuleSet variables.
Its HighWaterMark and RunningStandby variables may also be
changed."
::= { flowManagerInfoEntry 8 }
flowManagerRunningStandby OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set to true(1) by the meter to indicate that it has switched
to runnning this task's StandbyRuleSet in place of its
<span class="grey">Brownlee Standards Track [Page 23]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-24" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
CurrentRuleSet. To switch back to the CurrentRuleSet, the
manager may simply set this variable to false(2)."
DEFVAL { false }
::= { flowManagerInfoEntry 9 }
--
-- Control Group: General Meter Control Variables
--
flowFloodMark OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value expressed as a percentage, interpreted by the meter
as an indication of how full the flow table should be before
it should take some action to avoid running out of resources
to handle new flows, as discussed in <a href="#section-4.6">section 4.6</a> (Handling
Increasing Traffic Levels) of the RTFM Architecture RFC
[<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>].
Values of 0% or 100% disable the checking represented by
this variable."
DEFVAL { 95 } -- Enabled by default.
::= { flowControl 5 }
flowInactivityTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in seconds since the last packet seen, after which
a flow becomes 'idle.' Note that although a flow may be
idle, it will not be discarded (and its memory recovered)
until after its data has been collected by all the meter
readers registered for its RuleSet."
DEFVAL { 600 } -- 10 minutes
::= { flowControl 6 }
flowActiveFlows OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of flows which are currently in use."
::= { flowControl 7 }
flowMaxFlows OBJECT-TYPE
<span class="grey">Brownlee Standards Track [Page 24]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-25" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of flows allowed in the meter's
flow table. At present this is determined when the meter
is first started up."
::= { flowControl 8 }
flowFloodMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates that the meter has passed its FloodMark and is
not running in its normal mode.
When the manager notices this it should take action to remedy
the problem which caused the flooding. It should then monitor
flowActiveFlows so as to determine when the flood has receded.
At that point the manager may set flowFloodMode to false(2) to
resume normal operation."
::= { flowControl 9 }
--
-- The Flow Table
--
-- This is a table kept by a meter, with one flow data entry for every
-- flow being measured. Each flow data entry stores the attribute
-- values for a traffic flow. Details of flows and their attributes
-- are given in the 'Traffic Flow Measurement: Architecture'
-- document [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>].
-- From time to time a meter reader may sweep the flow table so as
-- to read counts. This is most effectively achieved by using the
-- TimeMark variable together with successive GetBulk requests to
-- retrieve the values of the desired flow attribute variables.
-- This scheme allows multiple meter readers to independently use the
-- same meter; the meter readers do not have to be synchronised and
-- they may use different collection intervals.
-- If identical sets of counts are required from a meter, a manager
-- could achieve this using two identical copies of a RuleSet in that
-- meter and switching back and forth between them. This is discussed
-- further in the RTFM Architecture document [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>].
<span class="grey">Brownlee Standards Track [Page 25]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-26" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
flowDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of all flows being measured."
::= { flowData 1 }
flowDataEntry OBJECT-TYPE
SYNTAX FlowDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The flow data record for a particular flow."
INDEX { flowDataRuleSet, flowDataTimeMark, flowDataIndex }
::= { flowDataTable 1 }
FlowDataEntry ::= SEQUENCE {
flowDataIndex Integer32,
flowDataTimeMark TimeFilter,
flowDataStatus INTEGER,
flowDataSourceInterface Integer32,
flowDataSourceAdjacentType AdjacentType,
flowDataSourceAdjacentAddress AdjacentAddress,
flowDataSourceAdjacentMask AdjacentAddress,
flowDataSourcePeerType PeerType,
flowDataSourcePeerAddress PeerAddress,
flowDataSourcePeerMask PeerAddress,
flowDataSourceTransType TransportType,
flowDataSourceTransAddress TransportAddress,
flowDataSourceTransMask TransportAddress,
flowDataDestInterface Integer32,
flowDataDestAdjacentType AdjacentType,
flowDataDestAdjacentAddress AdjacentAddress,
flowDataDestAdjacentMask AdjacentAddress,
flowDataDestPeerType PeerType,
flowDataDestPeerAddress PeerAddress,
flowDataDestPeerMask PeerAddress,
flowDataDestTransType TransportType,
flowDataDestTransAddress TransportAddress,
flowDataDestTransMask TransportAddress,
flowDataPDUScale Integer32,
flowDataOctetScale Integer32,
flowDataRuleSet Integer32,
<span class="grey">Brownlee Standards Track [Page 26]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-27" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
flowDataToOctets Counter64, -- Source->Dest
flowDataToPDUs Counter64,
flowDataFromOctets Counter64, -- Dest->Source
flowDataFromPDUs Counter64,
flowDataFirstTime TimeStamp, -- Activity times
flowDataLastActiveTime TimeStamp,
flowDataSourceSubscriberID OCTET STRING,
flowDataDestSubscriberID OCTET STRING,
flowDataSessionID OCTET STRING,
flowDataSourceClass Integer32,
flowDataDestClass Integer32,
flowDataClass Integer32,
flowDataSourceKind Integer32,
flowDataDestKind Integer32,
flowDataKind Integer32
}
flowDataIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Value of this flow data record's index within the meter's
flow table."
::= { flowDataEntry 1 }
flowDataTimeMark OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A TimeFilter for this entry. Allows GetNext and GetBulk
to find flow table rows which have changed since a specified
value of the meter's Uptime."
::= { flowDataEntry 2 }
flowDataStatus OBJECT-TYPE
SYNTAX INTEGER { inactive(1), current(2) }
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Status of this flow data record."
::= { flowDataEntry 3 }
flowDataSourceInterface OBJECT-TYPE
SYNTAX Integer32
<span class="grey">Brownlee Standards Track [Page 27]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-28" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the interface associated with the source address
for this flow. It's value is one of those contained in the
ifIndex field of the meter's interfaces table."
::= { flowDataEntry 4 }
flowDataSourceAdjacentType OBJECT-TYPE
SYNTAX AdjacentType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Adjacent address type of the source for this flow.
If metering is being performed at the network level,
AdjacentType will indicate the medium for the interface on
which the flow was observed and AdjacentAddress will be the
MAC address for that interface. This is the usual case.
If traffic is being metered inside a tunnel, AdjacentType will
be the peer type of the host at the end of the tunnel and
AdjacentAddress will be the peer address for that host."
::= { flowDataEntry 5 }
flowDataSourceAdjacentAddress OBJECT-TYPE
SYNTAX AdjacentAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Address of the adjacent device on the path for the source
for this flow."
::= { flowDataEntry 6 }
flowDataSourceAdjacentMask OBJECT-TYPE
SYNTAX AdjacentAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
comparing the adjacent source address for this flow."
::= { flowDataEntry 7 }
flowDataSourcePeerType OBJECT-TYPE
SYNTAX PeerType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
<span class="grey">Brownlee Standards Track [Page 28]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-29" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
"Peer address type of the source for this flow."
::= { flowDataEntry 8 }
flowDataSourcePeerAddress OBJECT-TYPE
SYNTAX PeerAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Address of the peer device for the source of this flow."
::= { flowDataEntry 9 }
flowDataSourcePeerMask OBJECT-TYPE
SYNTAX PeerAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
comparing the source peer address for this flow."
::= { flowDataEntry 10 }
flowDataSourceTransType OBJECT-TYPE
SYNTAX TransportType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transport address type of the source for this flow. The
value of this attribute will depend on the peer address type."
::= { flowDataEntry 11 }
flowDataSourceTransAddress OBJECT-TYPE
SYNTAX TransportAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transport address for the source of this flow."
::= { flowDataEntry 12 }
flowDataSourceTransMask OBJECT-TYPE
SYNTAX TransportAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
comparing the transport source address for this flow."
::= { flowDataEntry 13 }
flowDataDestInterface OBJECT-TYPE
SYNTAX Integer32
<span class="grey">Brownlee Standards Track [Page 29]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-30" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the interface associated with the dest address for
this flow. This value is one of the values contained in the
ifIndex field of the interfaces table."
::= { flowDataEntry 14 }
flowDataDestAdjacentType OBJECT-TYPE
SYNTAX AdjacentType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Adjacent address type of the destination for this flow."
::= { flowDataEntry 15 }
flowDataDestAdjacentAddress OBJECT-TYPE
SYNTAX AdjacentAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Address of the adjacent device on the path for the
destination for this flow."
::= { flowDataEntry 16 }
flowDataDestAdjacentMask OBJECT-TYPE
SYNTAX AdjacentAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
comparing the adjacent destination address for this flow."
::= { flowDataEntry 17 }
flowDataDestPeerType OBJECT-TYPE
SYNTAX PeerType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Peer address type of the destination for this flow."
::= { flowDataEntry 18 }
flowDataDestPeerAddress OBJECT-TYPE
SYNTAX PeerAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Address of the peer device for the destination of this flow."
<span class="grey">Brownlee Standards Track [Page 30]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-31" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
::= { flowDataEntry 19 }
flowDataDestPeerMask OBJECT-TYPE
SYNTAX PeerAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
comparing the destination peer type for this flow."
::= { flowDataEntry 20 }
flowDataDestTransType OBJECT-TYPE
SYNTAX TransportType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transport address type of the destination for this flow. The
value of this attribute will depend on the peer address type."
::= { flowDataEntry 21 }
flowDataDestTransAddress OBJECT-TYPE
SYNTAX TransportAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transport address for the destination of this flow."
::= { flowDataEntry 22 }
flowDataDestTransMask OBJECT-TYPE
SYNTAX TransportAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
comparing the transport destination address for this flow."
::= { flowDataEntry 23 }
flowDataPDUScale OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The scale factor applied to this particular flow. Indicates
the number of bits the PDU counter values should be moved left
to obtain the actual values."
::= { flowDataEntry 24 }
flowDataOctetScale OBJECT-TYPE
<span class="grey">Brownlee Standards Track [Page 31]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-32" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The scale factor applied to this particular flow. Indicates
the number of bits the octet counter values should be moved
left to obtain the actual values."
::= { flowDataEntry 25 }
flowDataRuleSet OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RuleSet number of the RuleSet which created this flow.
Allows a manager to use GetNext or GetBulk requests to find
flows belonging to a particular RuleSet."
::= { flowDataEntry 26 }
flowDataToOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of octets flowing from source to destination
for this flow."
::= { flowDataEntry 27 }
flowDataToPDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of packets flowing from source to destination
for this flow."
::= { flowDataEntry 28 }
flowDataFromOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of octets flowing from destination to source
for this flow."
::= { flowDataEntry 29 }
flowDataFromPDUs OBJECT-TYPE
SYNTAX Counter64
<span class="grey">Brownlee Standards Track [Page 32]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-33" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of packets flowing from destination to source
for this flow."
::= { flowDataEntry 30 }
flowDataFirstTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time at which this flow was first entered in the table"
::= { flowDataEntry 31 }
flowDataLastActiveTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last time this flow had activity, i.e. the time of
arrival of the most recent PDU belonging to this flow."
::= { flowDataEntry 32 }
flowDataSourceSubscriberID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Subscriber ID associated with the source address for this
flow. A Subscriber ID is an unspecified text string, used
to ascribe traffic flows to individual users. At this time
the means by which a Subscriber ID may be associated with a
flow is unspecified."
::= { flowDataEntry 33 }
flowDataDestSubscriberID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Subscriber ID associated with the destination address for
this flow. A Subscriber ID is an unspecified text string,
used to ascribe traffic flows to individual users. At this
time the means by which a Subscriber ID may be associated
with a flow is unspecified."
::= { flowDataEntry 34 }
<span class="grey">Brownlee Standards Track [Page 33]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-34" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
flowDataSessionID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Session ID for this flow. Such an ID might be allocated
by a network access server to distinguish a series of sessions
between the same pair of addresses, which would otherwise
appear to be parts of the same accounting flow."
::= { flowDataEntry 35 }
flowDataSourceClass OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Source class for this flow. Determined by the rules, set by
a PushRule action when this flow was entered in the table."
::= { flowDataEntry 36 }
flowDataDestClass OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Destination class for this flow. Determined by the rules, set
by a PushRule action when this flow was entered in the table."
::= { flowDataEntry 37 }
flowDataClass OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Class for this flow. Determined by the rules, set by a
PushRule action when this flow was entered in the table."
::= { flowDataEntry 38 }
flowDataSourceKind OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Source kind for this flow. Determined by the rules, set by
a PushRule action when this flow was entered in the table."
::= { flowDataEntry 39 }
flowDataDestKind OBJECT-TYPE
<span class="grey">Brownlee Standards Track [Page 34]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-35" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Destination kind for this flow. Determined by the rules, set
by a PushRule action when this flow was entered in the table."
::= { flowDataEntry 40 }
flowDataKind OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Class for this flow. Determined by the rules, set by a
PushRule action when this flow was entered in the table."
::= { flowDataEntry 41 }
--
-- The Activity Column Table
--
flowColumnActivityTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowColumnActivityEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Index into the Flow Table. Allows a meter reader to retrieve
a list containing the flow table indexes of flows which were
last active at or after a given time, together with the values
of a specified attribute for each such flow."
::= { flowData 2 }
flowColumnActivityEntry OBJECT-TYPE
SYNTAX FlowColumnActivityEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The Column Activity Entry for a particular attribute,
activity time and flow."
INDEX { flowColumnActivityAttribute, flowColumnActivityTime,
flowColumnActivityIndex }
::= { flowColumnActivityTable 1 }
FlowColumnActivityEntry ::= SEQUENCE {
flowColumnActivityAttribute FlowAttributeNumber,
flowColumnActivityTime TimeFilter,
flowColumnActivityIndex Integer32,
flowColumnActivityData OCTET STRING
<span class="grey">Brownlee Standards Track [Page 35]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-36" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
}
flowColumnActivityAttribute OBJECT-TYPE
SYNTAX FlowAttributeNumber
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Specifies the attribute for which values are required from
active flows."
::= { flowColumnActivityEntry 1 }
flowColumnActivityTime OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This variable is a copy of flowDataLastActiveTime in the
flow data record identified by the flowColumnActivityIndex
value of this flowColumnActivityTable entry."
::= { flowColumnActivityEntry 2 }
flowColumnActivityIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Index of a flow table entry which was active at or after
a specified flowColumnActivityTime."
::= { flowColumnActivityEntry 3 }
flowColumnActivityData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3..1000))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Collection of attribute data for flows active after
flowColumnActivityTime. Within the OCTET STRING is a
sequence of { flow index, attribute value } pairs, one for
each active flow. The end of the sequence is marked by a
flow index value of 0, indicating that there are no more
rows in this column.
The format of objects inside flowColumnFlowData is as follows.
All numbers are unsigned. Numbers and strings appear with
their high-order bytes leading. Numbers are fixed size, as
specified by their SYNTAX in the flow table (above), i.e. one
octet for flowAddressType and small constants, and four octets
for Counter and TimeStamp. Strings are variable-length, with
<span class="grey">Brownlee Standards Track [Page 36]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-37" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
the length given in a single leading octet.
The following is an attempt at an ASN.1 definition of
flowColumnActivityData:
flowColumnActivityData ::= SEQUENCE flowRowItemEntry
flowRowItemEntry ::= SEQUENCE {
flowRowNumber Integer32 (1..65535),
-- 0 indicates the end of this column
flowDataValue flowDataType -- Choice depends on attribute
}
flowDataType ::= CHOICE {
flowByteValue Integer32 (1..255),
flowShortValue Integer32 (1..65535),
flowLongValue Integer32,
flowStringValue OCTET STRING -- Length (n) in first byte,
-- n+1 bytes total length, trailing zeroes truncated
}"
::= { flowColumnActivityEntry 4 }
--
-- The Data Package Table
--
flowDataPackageTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowDataPackageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index into the Flow Table. Allows a meter reader to retrieve
a sequence containing the values of a specified set of
attributes for a flow which came from a specified RuleSet and
which was last active at or after a given time."
::= { flowData 3 }
flowDataPackageEntry OBJECT-TYPE
SYNTAX FlowDataPackageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The data package containing selected variables from
active rows in the flow table."
INDEX { flowPackageSelector,
flowPackageRuleSet, flowPackageTime, flowPackageIndex }
::= { flowDataPackageTable 1 }
FlowDataPackageEntry ::= SEQUENCE {
flowPackageSelector OCTET STRING,
<span class="grey">Brownlee Standards Track [Page 37]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-38" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
flowPackageRuleSet Integer32,
flowPackageTime TimeFilter,
flowPackageIndex Integer32,
flowPackageData OCTET STRING
}
flowPackageSelector OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies the attributes for which values are required from
an active flow. These are encoded as a sequence of octets
each containing a FlowAttribute number, preceded by an octet
giving the length of the sequence (not including the length
octet). For a flowPackageSelector to be valid, it must
contain at least one attribute."
::= { flowDataPackageEntry 1 }
flowPackageRuleSet OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies the index (in the flowRuleSetInfoTable) of the rule
set which produced the required flow."
::= { flowDataPackageEntry 2 }
flowPackageTime OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable is a copy of flowDataLastActiveTime in the
flow data record identified by the flowPackageIndex
value of this flowPackageTable entry."
::= { flowDataPackageEntry 3 }
flowPackageIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of a flow table entry which was active at or after
a specified flowPackageTime."
::= { flowDataPackageEntry 4 }
flowPackageData OBJECT-TYPE
<span class="grey">Brownlee Standards Track [Page 38]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-39" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A collection of attribute values for a single flow, as
specified by this row's indexes. The attribute values are
contained within a BER-encoded sequence [<a href="#ref-ASN-1" title="International Standard 8824">ASN-1</a>, <a href="#ref-ASN-BER" title="International Organization for Standardization">ASN-BER</a>],
in the order they appear in their flowPackageSelector.
For example, to retrieve a flowPackage containing values for
attributes 11, 18 and 29, for a flow in RuleSet 7, with flow
index 3447, one would GET the package whose Object Identifier
(OID) is
flowPackageData . 3.11.18.29 . 7. 0 . 3447
To get a package for the next such flow which had been
active since time 12345 one would GETNEXT the package whose
Object Identifier (OID) is
flowPackageData . 3.11.18.29 . 7. 12345 . 3447"
::= { flowDataPackageEntry 5 }
--
-- The Rule Table
--
-- This is an array of RuleSets; the 'running' ones are indicated
-- by the entries in the meter's flowManagerInfoTable. Several
-- RuleSets can be held in a meter so that the manager can change the
-- running RuleSets easily, for example with time of day. Note that
-- a manager may not change the rules in any RuleSet currently
-- referenced within the flowManagerInfoTable (either as 'current' or
-- 'standby')! See the 'Traffic Flow Measurement: Architecture'
-- document [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>] for details of rules and how they are used.
-- Space for a RuleSet is allocated by setting the value of
-- flowRuleInfoSize in the rule table's flowRuleSetInfoTable row.
-- Values for each row in the RuleSet (Selector, Mask, MatchedValue,
-- Action and Parameter) can then be set by the meter.
-- Although an individual rule within a RuleSet could be modified,
-- it is much safer to simply download a complete new RuleSet.
flowRuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains all the RuleSets which may be used by the meter."
<span class="grey">Brownlee Standards Track [Page 39]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-40" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
::= { flowRules 1 }
flowRuleEntry OBJECT-TYPE
SYNTAX FlowRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The rule record itself."
INDEX { flowRuleSet, flowRuleIndex }
::= { flowRuleTable 1 }
FlowRuleEntry ::= SEQUENCE {
flowRuleSet Integer32,
flowRuleIndex Integer32,
flowRuleSelector RuleAttributeNumber,
flowRuleMask RuleAddress,
flowRuleMatchedValue RuleAddress,
flowRuleAction ActionNumber,
flowRuleParameter Integer32
}
flowRuleSet OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Selects a RuleSet from the array of RuleSets."
::= { flowRuleEntry 1 }
flowRuleIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index into the Rule table. N.B: These values will
normally be consecutive, given the fall-through semantics
of processing the table."
::= { flowRuleEntry 2 }
flowRuleSelector OBJECT-TYPE
SYNTAX RuleAttributeNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the attribute to be matched.
null(0) is a special case; null rules always succeed.
<span class="grey">Brownlee Standards Track [Page 40]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-41" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
matchingStoD(50) is set by the meter's Packet Matching Engine.
Its value is true(1) if the PME is attempting to match the
packet with its addresses in Source-to-Destination order (i.e.
as they appear in the packet), and false(2) otherwise.
Details of how packets are matched are given in the 'Traffic
Flow Measurement: Architecture' document [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>].
v1(51), v2(52), v3(53), v4(54) and v5(55) select meter
variables, each of which can hold the name (i.e. selector
value) of an address attribute. When one of these is used
as a selector, its value specifies the attribute to be
tested. Variable values are set by an Assign action."
::= { flowRuleEntry 3 }
flowRuleMask OBJECT-TYPE
SYNTAX RuleAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The initial mask used to compute the desired value. If the
mask is zero the rule's test will always succeed."
::= { flowRuleEntry 4 }
flowRuleMatchedValue OBJECT-TYPE
SYNTAX RuleAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The resulting value to be matched for equality.
Specifically, if the attribute chosen by the flowRuleSelector
logically ANDed with the mask specified by the flowRuleMask
equals the value specified in the flowRuleMatchedValue, then
continue processing the table entry based on the action
specified by the flowRuleAction entry. Otherwise, proceed to
the next entry in the rule table."
::= { flowRuleEntry 5 }
flowRuleAction OBJECT-TYPE
SYNTAX ActionNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The action to be taken if this rule's test succeeds, or if
the meter's 'test' flag is off. Actions are opcodes for the
meter's Packet Matching Engine; details are given in the
'Traffic Flow Measurement: Architecture' document [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>]."
::= { flowRuleEntry 6 }
flowRuleParameter OBJECT-TYPE
<span class="grey">Brownlee Standards Track [Page 41]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-42" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A parameter value providing extra information for this rule's
action. Most of the actions use the parameter value to specify
which rule to execute after this rule's test has failed; details
are given in the 'Traffic Flow Measurement: Architecture'
document [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>]."
::= { flowRuleEntry 7 }
--
-- Traffic Flow Meter conformance statement
--
flowMIBCompliances
OBJECT IDENTIFIER ::= { flowMIBConformance 1 }
flowMIBGroups
OBJECT IDENTIFIER ::= { flowMIBConformance 2 }
flowControlGroup OBJECT-GROUP
OBJECTS {
flowRuleInfoSize, flowRuleInfoOwner,
flowRuleInfoTimeStamp, flowRuleInfoStatus,
flowRuleInfoName,
flowRuleInfoRulesReady,
flowRuleInfoFlowRecords,
flowInterfaceSampleRate,
flowInterfaceLostPackets,
flowReaderTimeout, flowReaderOwner,
flowReaderLastTime, flowReaderPreviousTime,
flowReaderStatus, flowReaderRuleSet,
flowManagerCurrentRuleSet, flowManagerStandbyRuleSet,
flowManagerHighWaterMark,
flowManagerCounterWrap,
flowManagerOwner, flowManagerTimeStamp,
flowManagerStatus, flowManagerRunningStandby,
flowFloodMark,
flowInactivityTimeout, flowActiveFlows,
flowMaxFlows, flowFloodMode }
STATUS deprecated
DESCRIPTION
"The control group defines objects which are used to control
an accounting meter."
::= {flowMIBGroups 1 }
flowDataTableGroup OBJECT-GROUP
<span class="grey">Brownlee Standards Track [Page 42]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-43" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
OBJECTS {
-- flowDataIndex, <- INDEX, not-accessible
flowDataStatus,
flowDataSourceInterface,
flowDataSourceAdjacentType,
flowDataSourceAdjacentAddress, flowDataSourceAdjacentMask,
flowDataSourcePeerType,
flowDataSourcePeerAddress, flowDataSourcePeerMask,
flowDataSourceTransType,
flowDataSourceTransAddress, flowDataSourceTransMask,
flowDataDestInterface,
flowDataDestAdjacentType,
flowDataDestAdjacentAddress, flowDataDestAdjacentMask,
flowDataDestPeerType,
flowDataDestPeerAddress, flowDataDestPeerMask,
flowDataDestTransType,
flowDataDestTransAddress, flowDataDestTransMask,
-- flowDataRuleSet, <- INDEX, not-accessible
flowDataToOctets, flowDataToPDUs,
flowDataFromOctets, flowDataFromPDUs,
flowDataFirstTime, flowDataLastActiveTime,
flowDataSourceClass, flowDataDestClass, flowDataClass,
flowDataSourceKind, flowDataDestKind, flowDataKind
}
STATUS deprecated
DESCRIPTION
"The flow table group defines objects which provide the
structure for the flow table, including the creation time
and activity time indexes into it. In addition it defines
objects which provide a base set of flow attributes for the
adjacent, peer and transport layers, together with a flow's
counters and times. Finally it defines a flow's class and
kind attributes, which are set by rule actions."
::= {flowMIBGroups 2 }
flowDataScaleGroup OBJECT-GROUP
OBJECTS {
flowManagerCounterWrap,
flowDataPDUScale, flowDataOctetScale
}
STATUS deprecated
DESCRIPTION
"The flow scale group defines objects which specify scale
factors for counters."
::= {flowMIBGroups 3 }
flowDataSubscriberGroup OBJECT-GROUP
OBJECTS {
<span class="grey">Brownlee Standards Track [Page 43]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-44" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
flowDataSourceSubscriberID, flowDataDestSubscriberID,
flowDataSessionID
}
STATUS current
DESCRIPTION
"The flow subscriber group defines objects which may be used
to identify the end point(s) of a flow."
::= {flowMIBGroups 4 }
flowDataColumnTableGroup OBJECT-GROUP
OBJECTS {
flowColumnActivityAttribute,
flowColumnActivityIndex,
flowColumnActivityTime,
flowColumnActivityData
}
STATUS deprecated
DESCRIPTION
"The flow column table group defines objects which can be used
to collect part of a column of attribute values from the flow
table."
::= {flowMIBGroups 5 }
flowDataPackageGroup OBJECT-GROUP
OBJECTS {
flowPackageData
}
STATUS current
DESCRIPTION
"The data package group defines objects which can be used
to collect a specified set of attribute values from a row of
the flow table."
::= {flowMIBGroups 6 }
flowRuleTableGroup OBJECT-GROUP
OBJECTS {
flowRuleSelector,
flowRuleMask, flowRuleMatchedValue,
flowRuleAction, flowRuleParameter
}
STATUS current
DESCRIPTION
"The rule table group defines objects which hold the set(s)
of rules specifying which traffic flows are to be accounted
for."
::= {flowMIBGroups 7 }
flowDataScaleGroup2 OBJECT-GROUP
<span class="grey">Brownlee Standards Track [Page 44]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-45" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
OBJECTS {
-- flowManagerCounterWrap, <- Deprecated
flowDataPDUScale, flowDataOctetScale
}
STATUS current
DESCRIPTION
"The flow scale group defines objects which specify scale
factors for counters. This group replaces the earlier
version of flowDataScaleGroup above (now deprecated)."
::= {flowMIBGroups 8}
flowControlGroup2 OBJECT-GROUP
OBJECTS {
flowRuleInfoSize, flowRuleInfoOwner,
flowRuleInfoTimeStamp, flowRuleInfoStatus,
flowRuleInfoName,
-- flowRuleInfoRulesReady, <- Deprecated
flowRuleInfoFlowRecords,
flowInterfaceSampleRate,
flowInterfaceLostPackets,
flowReaderTimeout, flowReaderOwner,
flowReaderLastTime, flowReaderPreviousTime,
flowReaderStatus, flowReaderRuleSet,
flowManagerCurrentRuleSet, flowManagerStandbyRuleSet,
flowManagerHighWaterMark,
-- flowManagerCounterWrap, <- Moved to DataScaleGroup
flowManagerOwner, flowManagerTimeStamp,
flowManagerStatus, flowManagerRunningStandby,
flowFloodMark,
flowInactivityTimeout, flowActiveFlows,
flowMaxFlows, flowFloodMode }
STATUS current
DESCRIPTION
"The control group defines objects which are used to control
an accounting meter. It replaces the earlier version of
flowControlGroup above (now deprecated)."
::= {flowMIBGroups 9 }
flowMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for a Traffic Flow Meter."
MODULE
MANDATORY-GROUPS {
flowControlGroup2,
flowDataTableGroup,
flowDataPackageGroup,
flowRuleTableGroup
<span class="grey">Brownlee Standards Track [Page 45]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-46" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
}
::= { flowMIBCompliances 1 }
END
<span class="grey">Brownlee Standards Track [Page 46]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-47" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
<span class="h2"><a class="selflink" id="section-5" href="#section-5">5</a> Security Considerations</span>
<span class="h3"><a class="selflink" id="section-5.1" href="#section-5.1">5.1</a> SNMP Concerns</span>
There are a number of management objects defined in this MIB that
have a MAX-ACCESS clause of read-write and/or read-create. Such
objects may be considered sensitive or vulnerable in some network
environments. The support for SET operations in a non-secure
environment without proper protection can have a negative effect on
network operations.
There are a number of managed objects in this MIB that may contain
sensitive information. These include all the objects in the Control
Group (since they control access to meter resources by Managers and
Meter Readers) and those in the Flow Table (since they hold the
collected traffic flow data).
It is thus important to control even GET access to these objects and
possibly to even encrypt the values of these object when sending them
over the network via SNMP. Not all versions of SNMP provide features
for such a secure environment.
SNMPv1 by itself is not a secure environment. Even if the network
itself is secure (for example by using IPSec), even then, there is no
control as to who on the secure network is allowed to access and
GET/SET (read/change/create/delete) the objects in this MIB.
It is recommended that the implementers consider the security
features as provided by the SNMPv3 framework. Specifically, the use
of the User-based Security Model [<a href="./rfc2574" title=""User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)"">RFC2574</a>] and the View-based Access
Control Model [<a href="./rfc2575" title=""View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)"">RFC2575</a>] is recommended.
It is then a customer/user responsibility to ensure that the SNMP
entity giving access to an instance of this MIB is properly
configured to give access to the objects only to those principals
(users) that have legitimate rights to indeed GET or SET
(change/create/delete) them.
<span class="h3"><a class="selflink" id="section-5.2" href="#section-5.2">5.2</a> Traffic Meter Concerns</span>
This MIB describes how an RTFM traffic meter is controlled, and
provides a way for traffic flow data to be retrieved from it by a
meter reader. This is essentially an application using SNMP as a
method of communication between co-operating hosts; it does not - in
itself - have any inherent security risks.
<span class="grey">Brownlee Standards Track [Page 47]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-48" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
Since, however, the traffic flow data can be extremely valuable for
network management purposes it is vital that sensible precautions be
taken to keep the meter and its data secure. In particular, an
attacker must not be permitted to write any of the meter's variables!
This requires that access to the meter for control purposes (e.g.
loading RuleSets and reading flow data) be restricted. Such
restriction could be achieved in many ways, for example:
- Physical Separation. Meter(s) and meter reader(s) could be
deployed so that control capabilities are kept within a separate
network, access to which is carefully controlled.
- Application-layer Security. A minimal level of security for SNMP
can be provided by using 'community' strings (which are essentially
clear-text passwords) with SNMPv2C [<a href="./rfc1157" title=""Simple Network Management Protocol"">RFC1157</a>]. Where stronger
security is needed, users should consider using the User-based
Security Model [<a href="./rfc2574" title=""User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)"">RFC2574</a>] and the View-based Access Control Model
[<a href="./rfc2575" title=""View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)"">RFC2575</a>].
- Lower-layer Security. Access to the meter can be protected using
encryption at the network layer. For example, one could run SNMP
to the meter through an encrypted TCP tunnel.
When implementing a meter it may be sensible to use separate network
interfaces for control and for metering. If this is done the control
network can be set up so that it doesn't carry any 'user' traffic,
and the metering interfaces can ignore any user attempts to take
control of the meter.
Users should also consider how they will address attempts to
circumvent a meter, i.e. to prevent it from measuring flows. Such
attempts are essentially denial-of-service attacks on the metering
interfaces. For example
- Port Scan attacks. The attacker sends packets to each of a very
large number of IP (Address : Port) pairs. Each of these packets
creates a new flow in the meter; if there are enough of them the
meter will recognise a 'flood' condition, and will probably stop
creating new flows. As a minimum, users (and implementors) should
ensure that meters can recover from flood conditions as soon as
possible after they occur.
- Counter Wrap attacks: The attacker sends enough packets to cause
the counters in a flow to wrap several times between meter
readings, thus causing the counts to be artificially low. The
change to using 64-bit counters in this MIB reduces this problem
significantly.
<span class="grey">Brownlee Standards Track [Page 48]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-49" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
Users can reduce the severity of both the above attacks by ensuring
that their meters are read often enough to prevent them being
flooded. The resulting flow data will contain a record of the
attacking packets, which may well be useful in determining where any
attack came from.
<span class="h2"><a class="selflink" id="section-6" href="#section-6">6</a> IANA Considerations</span>
The RTFM Architecture document [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>], has two sets of assigned
numbers: Opcodes for the PME (Pattern Matching Engine) and RTFM
Attribute numbers. All the assigned numbers used in the Meter MIB
appear in Textual Conventions. The numbers they use are derived as
follows:
The MIB's 'Type' textual conventions use names and numbers from the
Assigned Numbers RFC [<a href="#ref-ASG-NBR" title=""Assigned Numbers"">ASG-NBR</a>]:
MediumType Uses ifType Definitions
PeerType Uses Address Family Numbers
TransportType Uses Protocol Numbers
The MIB's 'AttributeNumber' textual conventions use RTFM Attribute
names and numbers from the RTFM Architecture document [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>], or
other numbers allocated according to that document's IANA
Considerations section:
FlowAttributeNumber Have values stored in a flow table row
RuleAttributeNumber May be tested in a rule
The MIB's ActionNumber textual convention uses RTFM PME Opcode names
and numbers from the RTFM Architecture document [<a href="#ref-RTFM-ARC" title=""Traffic Flow Measurement: Architecture"">RTFM-ARC</a>], or other
numbers allocated according to that document's IANA Considerations
section.
<span class="grey">Brownlee Standards Track [Page 49]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-50" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
<span class="h2"><a class="selflink" id="section-7" href="#section-7">7</a> <a href="#appendix-A">Appendix A</a>: Changes Introduced Since <a href="./rfc2064">RFC 2064</a></span>
The first version of the Meter MIB was published as <a href="./rfc2064">RFC 2064</a> in
January 1997. The most significant changes since then are summarised
below.
- TEXTUAL CONVENTIONS: Greater use is made of textual conventions to
describe the various types of addresses used by the meter.
- PACKET MATCHING ATTRIBUTES: Computed attributes (e.g. FlowClass and
FlowKind) may now be tested. This allows one to use these
variables to store information during packet matching.
A new attribute, MatchingStoD, has been added. Its value is 1
while a packet is being matched with its adresses in 'wire'
(source-to-destination) order.
- FLOOD MODE: This is now a read-write variable. Setting it to
false(2) switches the meter out of flood mode and back to normal
operation.
- CONTROL TABLES: Several variables have been added to the RuleSet,
Reader and Manager tables to provide more effective control of the
meter's activities.
- FLOW TABLE: 64-bit counters are used for octet and PDU counts.
This reduces the problems caused by the wrap-around of 32-bit
counters in earlier versions.
flowDataRuleSet is now used as an index to the flow table. This
allows a meter reader to collect only those flow table rows created
by a specified RuleSet.
- DATA PACKAGES: This is a new table, allowing a meter reader to
retrieve values for a list of attributes from a flow as a single
object (a BER-encoded sequence [<a href="#ref-ASN-1" title="International Standard 8824">ASN-1</a>, <a href="#ref-ASN-BER" title="International Organization for Standardization">ASN-BER</a>]). It provides an
efficient way to recover flow data, particularly when used with
SNMP GetBulk requests.
Earlier versions had a 'Column Activity Table'; using this it was
difficult to collect all data for a flow efficiently in a single
SNMP request.
<span class="grey">Brownlee Standards Track [Page 50]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-51" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
<span class="h2"><a class="selflink" id="section-8" href="#section-8">8</a> Acknowledgements</span>
An early draft of this document was produced under the auspices of
the IETF's Accounting Working Group with assistance from the SNMP
Working Group and the Security Area Advisory Group. Particular
thanks are due to Jim Barnes, Sig Handelman and Stephen Stibler for
their support and their assistance with checking early versions of
the MIB.
Stephen Stibler shared the development workload of producing the MIB
changes summarized in chapter 5 (above).
<span class="h2"><a class="selflink" id="section-9" href="#section-9">9</a> Intellectual Property Notice</span>
The IETF takes no position regarding the validity or scope of any
intellectual property or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; neither does it represent that it
has made any effort to identify any such rights. Information on the
IETF's procedures with respect to rights in standards-track and
standards-related documentation can be found in <a href="https://www.rfc-editor.org/bcp/bcp11">BCP-11</a>. Copies of
claims of rights made available for publication and any assurances of
licenses to be made available, or the result of an attempt made to
obtain a general license or permission for the use of such
proprietary rights by implementers or users of this specification can
be obtained from the IETF Secretariat."
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights which may cover technology that may be required to practice
this standard. Please address the information to the IETF Executive
Director.
<span class="h2"><a class="selflink" id="section-10" href="#section-10">10</a> References</span>
[<a id="ref-ACT-BKG">ACT-BKG</a>] Mills, C., Hirsch, G. and G. Ruth, "Internet Accounting
Background", <a href="./rfc1272">RFC 1272</a>, November 1991.
[<a id="ref-ASG-NBR">ASG-NBR</a>] Reynolds, J. and J. Postel, "Assigned Numbers", STD 2,
<a href="./rfc1700">RFC 1700</a>, ISI, October 1994.
[<a id="ref-ASN-1">ASN-1</a>] Information processing systems - Open Systems
Interconnection - Specification of Abstract Syntax
Notation One (ASN.1), International Organization for
Standardization, International Standard 8824, December
1987.
<span class="grey">Brownlee Standards Track [Page 51]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-52" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
[<a id="ref-ASN-BER">ASN-BER</a>] Information processing systems - Open Systems
Interconnection - Specification of Basic Encoding Rules
for Abstract Notation One (ASN.1), International
Organization for Standardization, International Standard
8825, December 1987.
[<a id="ref-ENET-OBJ">ENET-OBJ</a>] Kastenholz, F., "Definitions of Managed Objects for the
Ethernet-like Interface Types", <a href="./rfc1643">RFC 1643</a>, July 1994.
[<a id="ref-FDDI-MIB">FDDI-MIB</a>] Case, J. and A. Rijsinghani, "FDDI Management Information
Base", <a href="./rfc1512">RFC 1512</a>, September 1993.
[<a id="ref-IPPM-FRM">IPPM-FRM</a>] Paxson, V., Almes, G., Mahdavi, J. and M. Mathis,
"Framework for IP Performance Metrics", <a href="./rfc2330">RFC 2330</a>, May
1998.
[<a id="ref-MIB-II">MIB-II</a>] McCloghrie, K. and M. Rose, "Management Information Base
for Network Management of TCP/IP-based internets: MIB-
II", STD 17, <a href="./rfc1213">RFC 1213</a>, March 1991.
[<a id="ref-RFC1155">RFC1155</a>] Rose, M., and K. McCloghrie, "Structure and
Identification of Management Information for TCP/IP-based
Internets", STD 16, <a href="./rfc1155">RFC 1155</a>, May 1990
[<a id="ref-RFC1157">RFC1157</a>] Case, J., Fedor, M., Schoffstall, M. and J. Davin,
"Simple Network Management Protocol", STD 15, <a href="./rfc1157">RFC 1157</a>,
May 1990.
[<a id="ref-RFC1212">RFC1212</a>] Rose, M. and K. McCloghrie, "Concise MIB Definitions",
STD 16, <a href="./rfc1212">RFC 1212</a>, March 1991.
[<a id="ref-RFC1215">RFC1215</a>] Rose, M., "A Convention for Defining Traps for use with
the SNMP", <a href="./rfc1215">RFC 1215</a>, March 1991
[<a id="ref-RFC1901">RFC1901</a>] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
"Introduction to Community-based SNMPv2", <a href="./rfc1901">RFC 1901</a>,
January 1996.
[<a id="ref-RFC1905">RFC1905</a>] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
"Protocol Operations for Version 2 of the Simple Network
Management Protocol (SNMPv2)", <a href="./rfc1905">RFC 1905</a>, January 1996.
[<a id="ref-RFC1906">RFC1906</a>] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
"Transport Mappings for Version 2 of the Simple Network
Management Protocol (SNMPv2)", <a href="./rfc1906">RFC 1906</a>, January 1996.
<span class="grey">Brownlee Standards Track [Page 52]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-53" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
[<a id="ref-RFC1908">RFC1908</a>] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
"Coexistence between version 1 and version 2 of the
Internet-standard Network Management Framework", <a href="./rfc1908">RFC</a>
<a href="./rfc1908">1908</a>, January 1996.
[<a id="ref-RFC2570">RFC2570</a>] Case, J., Mundy, R., Partain, D. and B. Stewart,
"Introduction to Version 3 of the Internet-standard
Network Management Framework", <a href="./rfc2570">RFC 2570</a>, April 1999.
[<a id="ref-RFC2571">RFC2571</a>] Harrington, D., Presuhn, R. and B. Wijnen, "An
Architecture for Describing SNMP Management Frameworks",
<a href="./rfc2571">RFC 2571</a>, April 1999.
[<a id="ref-RFC2572">RFC2572</a>] Case, J., Harrington D., Presuhn R. and B. Wijnen,
"Message Processing and Dispatching for the Simple
Network Management Protocol (SNMP)", <a href="./rfc2572">RFC 2572</a>, April
1999.
[<a id="ref-RFC2573">RFC2573</a>] Levi, D., Meyer, P. and B. Stewart, "SNMPv3
Applications", <a href="./rfc2573">RFC 2573</a>, April 1999.
[<a id="ref-RFC2574">RFC2574</a>] Blumenthal, U. and B. Wijnen, "User-based Security Model
(USM) for version 3 of the Simple Network Management
Protocol (SNMPv3)", <a href="./rfc2574">RFC 2574</a>, April 1999.
[<a id="ref-RFC2575">RFC2575</a>] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based
Access Control Model (VACM) for the Simple Network
Management Protocol (SNMP)", <a href="./rfc2575">RFC 2575</a>, April 1999.
[<a id="ref-RFC2578">RFC2578</a>] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
Rose, M. and S. Waldbusser, "Structure of Management
Information Version 2 (SMIv2)", STD 58, <a href="./rfc2578">RFC 2578</a>, April
1999.
[<a id="ref-RFC2579">RFC2579</a>] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
Rose, M. and S. Waldbusser, "Textual Conventions for
SMIv2", STD 58, <a href="./rfc2579">RFC 2579</a>, April 1999.
[<a id="ref-RFC2580">RFC2580</a>] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
Rose, M. and S. Waldbusser, "Conformance Statements for
SMIv2", STD 58, <a href="./rfc2580">RFC 2580</a>, April 1999.
[<a id="ref-RMON-MIB">RMON-MIB</a>] Waldbusser, S., "Remote Network Monitoring Management
Information Base", <a href="./rfc1757">RFC 1757</a>, February 1995.
[<a id="ref-RMON2-MIB">RMON2-MIB</a>] Waldbusser, S., "Remote Network Monitoring Management
Information Base Version 2 using SMIv2", <a href="./rfc2021">RFC 2021</a>,
January 1997.
<span class="grey">Brownlee Standards Track [Page 53]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-54" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
[<a id="ref-RTFM-ARC">RTFM-ARC</a>] Brownlee, N., Mills, C. and Ruth, G., "Traffic Flow
Measurement: Architecture", <a href="./rfc722">RFC 722</a>, October 1999.
[<a id="ref-UTF-8">UTF-8</a>] Yergeau, F., "UTF-8, a transformation format of ISO
10646", <a href="./rfc2279">RFC 2279</a>, January 1998.
[<a id="ref-V6-ADDR">V6-ADDR</a>] Hinden, R. and S. Deering, "IP Version 6 Addressing
Architecture", <a href="./rfc2373">RFC 2373</a>, July 1998.
<span class="h2"><a class="selflink" id="section-11" href="#section-11">11</a> Author's Address</span>
Nevil Brownlee
Information Technology Systems & Services
The University of Auckland
Private Bag 92-019
Auckland, New Zealand
Phone: +64 9 373 7599 x8941
EMail: n.brownlee@auckland.ac.nz
<span class="grey">Brownlee Standards Track [Page 54]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-55" ></span>
<span class="grey"><a href="./rfc2720">RFC 2720</a> Traffic Flow Measurement: Meter MIB October 1999</span>
<span class="h2"><a class="selflink" id="section-12" href="#section-12">12</a> Full Copyright Statement</span>
Copyright (C) The Internet Society (1999). All Rights Reserved.
This document and translations of it may be copied and furnished to
others, and derivative works that comment on or otherwise explain it
or assist in its implementation may be prepared, copied, published
and distributed, in whole or in part, without restriction of any
kind, provided that the above copyright notice and this paragraph are
included on all such copies and derivative works. However, this
document itself may not be modified in any way, such as by removing
the copyright notice or references to the Internet Society or other
Internet organizations, except as needed for the purpose of
developing Internet standards in which case the procedures for
copyrights defined in the Internet Standards process must be
followed, or as required to translate it into languages other than
English.
The limited permissions granted above are perpetual and will not be
revoked by the Internet Society or its successors or assigns.
This document and the information contained herein is provided on an
"AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Brownlee Standards Track [Page 55]
</pre>
|