1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013
|
<pre>Network Working Group T. Murphy, Jr.
Request for Comments: 2877 P. Rieth
Category: Informational J. Stevens
Updates: <a href="./rfc1205">1205</a> IBM Corporation
July 2000
5250 Telnet Enhancements
Status of this Memo
This memo provides information for the Internet community. It does
not specify an Internet standard of any kind. Distribution of this
memo is unlimited.
Copyright Notice
Copyright (C) The Internet Society (2000). All Rights Reserved.
Abstract
This memo describes the interface to the IBM 5250 Telnet server that
allows client Telnet to request a Telnet terminal or printer session
using a specific device name. If a requested device name is not
available, a method to retry the request using a new device name is
described. Methods to request specific Telnet session settings and
auto-signon function are also described.
By allowing a Telnet client to select the device name, the 5250
Telnet server opens the door for applications to set and/or extract
useful information about the Telnet client. Some possibilities are
1) selecting a customized device name associated with a particular
user profile name for National Language Support or subsystem routing,
2) connecting PC and network printers as clients and 3) auto-signon
using clear-text or DES-encrypted password exchange.
Applications may need to use system API's on the AS/400 in order to
extract Telnet session settings from the device name description.
Refer to the Retrieve Device Description (QDCRDEVD) API described in
the AS/400 System API book [<a href="#ref-3" title=""AS/400 System API Reference"">3</a>] on how to extract information using
the DEVD0600 and DEVD1100 templates.
This memo describes how the IBM 5250 Telnet server supports Work
Station Function (WSF) printers using 5250 Display Station Pass-
Through. A response code is returned by the Telnet server to
indicate success or failure of the WSF printer session.
<span class="grey">Murphy, et al. Informational [Page 1]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-2" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
Table of Contents
<a href="#section-1">1</a>. Enhancing Telnet Negotiations...................... <a href="#page-3">3</a>
<a href="#section-2">2</a>. Standard Telnet Option Negotiation................. <a href="#page-3">3</a>
<a href="#section-3">3</a>. Enhanced Telnet Option Negotiation................. <a href="#page-4">4</a>
<a href="#section-4">4</a>. Enhanced Display Emulation Support................. <a href="#page-7">7</a>
5. Enhanced Display Auto-Signon and Password
Encryption......................................... <a href="#page-8">8</a>
<a href="#section-5.1">5.1</a> Password Substitutes Processing.............. <a href="#page-12">12</a>
<a href="#section-5.2">5.2</a> Handling passwords of length 9 and 10........ <a href="#page-14">14</a>
<a href="#section-5.3">5.3</a> Example Password Substitute Calculation...... <a href="#page-15">15</a>
<a href="#section-6">6</a>. Device Name Collision Processing................... <a href="#page-15">15</a>
<a href="#section-7">7</a>. Enhanced Printer Emulation Support................. <a href="#page-16">16</a>
<a href="#section-8">8</a>. Telnet Printer Terminal Types...................... <a href="#page-18">18</a>
9. Telnet Printer Startup Response Record for Printer
Emulators.......................................... <a href="#page-20">20</a>
<a href="#section-9.1">9.1</a> Example of a Success Response Record......... <a href="#page-20">20</a>
<a href="#section-9.2">9.2</a> Example of an Error Response Record.......... <a href="#page-21">21</a>
<a href="#section-9.3">9.3</a> Response Codes............................... <a href="#page-22">22</a>
<a href="#section-10">10</a>. Printer Steady-State Pass-Through Interface........ <a href="#page-23">23</a>
<a href="#section-10.1">10.1</a> Example of a Print Record.................... <a href="#page-25">25</a>
<a href="#section-10.2">10.2</a> Example of a Print Complete Record........... <a href="#page-27">27</a>
<a href="#section-10.3">10.3</a> Example of a Null Print Record............... <a href="#page-27">27</a>
<a href="#section-11">11</a>. End-to-End Print Example........................... <a href="#page-28">28</a>
<a href="#section-12">12</a>. Authors' Note...................................... <a href="#page-33">33</a>
<a href="#section-13">13</a>. References......................................... <a href="#page-33">33</a>
<a href="#section-14">14</a>. Security Considerations............................ <a href="#page-35">35</a>
<a href="#section-15">15</a>. Authors' Addresses................................. <a href="#page-35">35</a>
<a href="#section-16">16</a>. Relation to Other RFC's............................ <a href="#page-35">35</a>
<a href="#section-17">17</a>. Full Copyright Statement........................... <a href="#page-36">36</a>
LIST OF FIGURES
Figure 1. Example of a success status response
record....................................... <a href="#page-20">20</a>
Figure 2. Example of an error response record.......... <a href="#page-21">21</a>
Figure 3. Layout of the printer pass-through
header....................................... <a href="#page-23">23</a>
Figure 4. Server sending client data with a print
record....................................... <a href="#page-26">26</a>
Figure 5. Client sending server a print complete
record....................................... <a href="#page-27">27</a>
Figure 6. Server sending client a null print
record....................................... <a href="#page-28">28</a>
<span class="grey">Murphy, et al. Informational [Page 2]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-3" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
<span class="h2"><a class="selflink" id="section-1" href="#section-1">1</a>. Enhancing Telnet Negotiations</span>
The 5250 Telnet server enables clients to negotiate both terminal and
printer device names through Telnet Environment Options Negotiations,
defined in the Standards Track <a href="./rfc1572">RFC 1572</a> [<a href="#ref-13" title=""Telnet Environment Option"">13</a>].
The purpose of <a href="./rfc1572">RFC 1572</a> is to exchange environment information using
a set of standard or custom variables. By using a combination of
both standard VAR's and custom USERVAR's, the 5250 Telnet server
allows client Telnet to request a pre-defined specific device by
name.
If no pre-defined device exists then the device will be created, with
client Telnet having the option to negotiate device attributes, such
as the code page, character set, keyboard type, etc.
Since printers can now be negotiated as a device name, new terminal
types have been defined to request printers. For example, you can
now negotiate "IBM-3812-1" and "IBM-5553-B01" as valid TERMINAL-TYPE
options [<a href="#ref-11" title=""Telnet Terminal-Type Option"">11</a>].
Finally, the 5250 Telnet server will allow exchange of user profile
and password information, where the password may be in either clear-
text or encrypted form. If a valid combination of profile and
password is received, then the client is allowed to bypass the sign-
on panel. The setting of the QRMTSIGN system value must be either
*VERIFY or *SAMEPRF for the bypass of the sign-on panel to succeed.
<span class="h2"><a class="selflink" id="section-2" href="#section-2">2</a>. Standard Telnet Option Negotiation</span>
Telnet server option negotiation typically begins with the issuance,
by the server, of an invitation to engage in terminal type
negotiation with the Telnet client (DO TERMINAL-TYPE) [<a href="#ref-11" title=""Telnet Terminal-Type Option"">11</a>]. The
client and server then enter into a series of sub-negotiations to
determine the level of terminal support that will be used. After the
terminal type is agreed upon, the client and server will normally
negotiate a required set of additional options (EOR [<a href="#ref-12" title=""Telnet End of Record Option"">12</a>], BINARY
[<a href="#ref-10" title=""Telnet Binary Transmission"">10</a>], SGA [<a href="#ref-15" title=""Telnet Supress Go Ahead Option"">15</a>]) that are required to support "transparent mode" or
full screen 5250/3270 block mode support. As soon as the required
options have been negotiated, the server will suspend further
negotiations, and begin with initializing the actual virtual device
on the AS/400. A typical exchange might start like the following:
<span class="grey">Murphy, et al. Informational [Page 3]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-4" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
AS/400 Telnet server Enhanced Telnet client
-------------------------- -------------------------
IAC DO TERMINAL-TYPE -->
<-- IAC WILL TERMINAL-TYPE
IAC SB TERMINAL-TYPE SEND
IAC SE -->
IAC SB TERMINAL-TYPE IS
<-- IBM-5555-C01 IAC SE
IAC DO EOR -->
<-- IAC WILL EOR
<-- IAC DO EOR
IAC WILL EOR -->
.
.
(other negotiations) .
Actual bytes transmitted in the above example are shown in hex below.
AS/400 Telnet server Enhanced Telnet client
-------------------------- -------------------------
FF FD 18 -->
<-- FF FB 18
FF FA 18 01 FF F0 -->
FF FA 18 00 49 42 4D 2D
35 35 35 35 2D 43 30 31
<-- FF F0
FF FD 19 -->
<-- FF FB 19
<-- FF FD 19
FF FB 19 -->
.
.
(other negotiations) .
Some negotiations are symmetrical between client and server and some
are negotiated in one direction only. Also, it is permissible and
common practice to bundle more than one response or request, or
combine a request with a response, so the actual exchange may look
different in practice to what is shown above.
<span class="h2"><a class="selflink" id="section-3" href="#section-3">3</a>. Enhanced Telnet Option Negotiation</span>
In order to accommodate the new environment option negotiations, the
server will bundle an environment option invitation along with the
standard terminal type invitation request to the client.
<span class="grey">Murphy, et al. Informational [Page 4]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-5" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
A client should either send a negative acknowledgment (WONT NEW-
ENVIRON), or at some point after completing terminal-type
negotiations, but before completing the full set of negotiations
required for 5250 transparent mode, engage in environment option
sub-negotiation with the server. A maximum of 1024 bytes of
environment strings may be sent to the server. A recommended
sequence might look like the following:
AS/400 Telnet server Enhanced Telnet client
-------------------------- -------------------------
IAC DO NEW-ENVIRON
IAC DO TERMINAL-TYPE -->
(2 requests bundled)
<-- IAC WILL NEW-ENVIRON
IAC SB NEW-ENVIRON SEND
VAR IAC SE -->
IAC SB NEW-ENVIRON IS
VAR "USER" VALUE "JONES"
USERVAR "DEVNAME"
VALUE "MYDEVICE07"
<-- IAC SE
<-- IAC WILL TERMINAL-TYPE
(do the terminal type
sequence first)
IAC SB TERMINAL-TYPE SEND
IAC SE -->
IAC SB TERMINAL-TYPE IS
<-- IBM-5555-C01 IAC SE
(terminal type negotiations
completed)
IAC DO EOR -->
(server will continue
with normal transparent
mode negotiations)
<-- IAC WILL EOR
.
.
(other negotiations) .
Actual bytes transmitted in the above example are shown in hex below.
AS/400 Telnet server Enhanced Telnet client
-------------------------- -------------------------
FF FD 27
FF FD 18 -->
(2 requests bundled)
<-- FF FB 27
FF FA 27 01 00 FF F0 -->
<span class="grey">Murphy, et al. Informational [Page 5]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-6" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
FF FA 27 00 00 55 53 45
52 01 4A 4F 4E 45 53 03
44 45 56 4E 41 4D 45 01
4D 59 44 45 56 49 43 45
<-- 30 37 FF F0
<-- FF FB 18
(do the terminal type
sequence first)
FF FA 18 01 FF F0 -->
FF FA 18 00 49 42 4D 2D
35 35 35 35 2D 43 30 31
<-- FF F0
FF FD 19 -->
(server will continue
with normal transparent
mode negotiations)
<-- FF FB 19
.
.
(other negotiations) .
<a href="./rfc1572">RFC 1572</a> defines 6 standard VAR's: USER, JOB, ACCT, PRINTER,
SYSTEMTYPE, and DISPLAY. The USER standard VAR will hold the value
of the AS/400 user profile name to be used in auto-signon requests.
The Telnet server will make no direct use of the additional 5 VAR's,
nor are any of them required to be sent. All standard VAR's and
their values that are received by the Telnet server will be placed in
a buffer, along with any USERVAR's received (described below), and
made available to a registered initialization exit program to be used
for any purpose desired.
There are some reasons you may want to send NEW-ENVIRON negotiations
prior to TERMINAL-TYPE negotiations. With AS/400 TELNET server,
several virtual device modes can be negotiated: 1) VTxxx device 2)
3270 device 3) 5250 device (includes Network Station). The virtual
device mode selected depends on the TERMINAL-TYPE negotiated plus any
other TELNET option negotiations necessary to support those modes.
The AS/400 TELNET server will create the desired virtual device at
the first opportunity it thinks it has all the requested attributes
needed to create the device. This can be as early as completion of
the TERMINAL-TYPE negotiations.
For the case of Transparent mode (5250 device), then the moment
TERMINAL-TYPE, BINARY, and EOR options are negotiated the TELNET
server will go create the virtual device. Receiving any NEW-ENVIRON
negotiations after these option negotiations are complete will result
in the NEW-ENVIRON negotiations having no effect on device
attributes, as the virtual device will have already been created.
<span class="grey">Murphy, et al. Informational [Page 6]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-7" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
So, for Transparent mode, NEW-ENVIRON negotiations are effectively
closed once EOR is negotiated, since EOR is generally the last option
done.
For other devices modes (such as VTxxx or 3270), you cannot be sure
when the AS/400 TELNET server thinks it has all the attributes to
create the device. Recall that NEW-ENVIRON negotiations are
optional, and therefore the AS/400 TELNET server need not wait for
any NEW-ENVIRON options prior to creating the virtual device. It is
in the clients best interest to send NEW-ENVIRON negotiations as soon
as possible, preferably before TERMINAL-TYPE is negotiated. That
way, the client can be sure the requested attributes were received
before the virtual device is created.
<span class="h2"><a class="selflink" id="section-4" href="#section-4">4</a>. Enhanced Display Emulation Support</span>
<a href="./rfc1572">RFC 1572</a> style USERVAR variables have been defined to allow a
compliant Telnet client more control over the Telnet server virtual
device on the AS/400. These USERVAR's allow the client Telnet to
create or select a previously created virtual device. If the virtual
device does not exist and must be created, then the USERVAR variables
are used to create and initialize the device attributes. If the
virtual device already exists, the device attributes are modified.
The USERVAR's defined to accomplish this are:
USERVAR VALUE EXAMPLE DESCRIPTION
-------- ---------------- ---------------- -------------------
DEVNAME us-ascii char(x) MYDEVICE07 Display device name
KBDTYPE us-ascii char(3) USB Keyboard type
CODEPAGE us-ascii char(y) 437 Code page
CHARSET us-ascii char(y) 1212 Character set
x - up to a maximum of 10 characters
y - up to a maximum of 5 characters
For a description of the KBDTYPE, CODEPAGE and CHARSET parameters and
their permissible values, refer to Chapter 8 in the Communications
Configuration Reference [<a href="#ref-5" title=""AS/400 Communications Configuration"">5</a>] and also to <a href="#appendix-C">Appendix C</a> in National
Language Support [<a href="#ref-16" title=""AS/400 National Language Support"">16</a>].
The CODEPAGE and CHARSET USERVAR's must be associated with a KBDTYPE
USERVAR. If either CODEPAGE or CHARSET are sent without KBDTYPE,
they will default to system values. A default value for KBDTYPE can
be sent to force CODEPAGE and CHARSET values to be used.
<span class="grey">Murphy, et al. Informational [Page 7]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-8" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
AS/400 system objects such as device names, user profiles, clear-text
passwords, programs, libraries, etc. are required to be specified in
English Upper Case (EUC). This includes:
Any letter (A-Z), any number (0-9), special characters (# $ _ @)
Therefore, where us-ascii is specified for VAR or USERVAR values, it
is recommended that upper-cased ASCII values be sent, which will be
converted to EBCDIC by the Telnet server.
A special case occurs for encrypted passwords (described in the next
section), where both the initial password and user profile used to
build the encrypted password must be EBCDIC English Upper Case, in
order to be properly authenticated by the Telnet server.
<span class="h2"><a class="selflink" id="section-5" href="#section-5">5</a>. Enhanced Display Auto-Signon and Password Encryption</span>
Several 5250 Telnet server specific USERVAR's will be defined. One
will carry a random seed to be used in Data Encryption Standard (DES)
password encryption, and another will carry the encrypted copy of the
password. This would use the same 7-step DES-based password
substitution scheme as APPC and Client Access. For a description of
DES encryption, refer to Federal Information Processing Standards
Publications (FIPS) 46-2 [<a href="#ref-17" title="January 22">17</a>] and 81 [<a href="#ref-18" title="Federal Information Processing Standards Publication 81">18</a>], which can be found at the
Federal Information Processing Standards Publications link:
<a href="http://www.itl.nist.gov/div897/pubs/by-num.htm">http://www.itl.nist.gov/div897/pubs/by-num.htm</a>
For a description of the 7-step password substitution scheme, refer
to these IBM Customer Support FTP Server links:
<a href="ftp://ftp.networking.ibm.com/pub/standards/ciw/sig/sec/pwsubciw.ps">ftp://ftp.networking.ibm.com/pub/standards/ciw/sig/sec/pwsubciw.ps</a>
<a href="ftp://ftp.networking.ibm.com/pub/standards/ciw/sig/sec/pwsubciw.ps.Z">ftp://ftp.networking.ibm.com/pub/standards/ciw/sig/sec/pwsubciw.ps.Z</a>
<a href="ftp://ftp.networking.ibm.com/pub/standards/ciw/sig/sec/pwsubciw.zip">ftp://ftp.networking.ibm.com/pub/standards/ciw/sig/sec/pwsubciw.zip</a>
If encrypted password exchange is not required, clear-text password
exchange is permitted using the same USERVAR's defined for
encryption. For this case, the random client seed should be set to
either an empty value (<a href="./rfc1572">RFC 1572</a> preferred method) or to hexadecimal
zeros to indicate the password is not encrypted, but is clear-text.
It should be noted that security of clear-text password exchange
cannot be guaranteed unless the network is physically protected or a
trusted network (such as an intranet). If your network is vulnerable
to IP address spoofing or directly connected to the Internet, you
should engage in encrypted password exchange to validate a clients
identity.
<span class="grey">Murphy, et al. Informational [Page 8]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-9" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
Additional VAR's and USERVAR's have also been defined to allow an
auto-signon user greater control over their startup environment,
similar to what is supported using the Open Virtual Terminal
(QTVOPNVT) API [<a href="#ref-3" title=""AS/400 System API Reference"">3</a>].
The standard VAR's supported to accomplish this are:
VAR VALUE EXAMPLE DESCRIPTION
-------- ---------------- ---------------- -------------------
USER us-ascii char(x) USERXYZ User profile name
x - up to a maximum of 10 characters
The custom USERVAR's defined to accomplish this are:
USERVAR VALUE EXAMPLE DESCRIPTION
-------- ---------------- ---------------- -------------------
IBMRSEED binary(8) 8-byte hex field Random client seed
IBMSUBSPW binary(10) 10-byte hex field Substitute password
IBMCURLIB us-ascii char(x) QGPL Current library
IBMIMENU us-ascii char(x) MAIN Initial menu
IBMPROGRAM us-ascii char(x) QCMD Program to call
x - up to a maximum of 10 characters
In order to communicate the server random seed value to the client,
the server will request a USERVAR name made up of a fixed part (the 8
characters "IBMRSEED" immediately followed by an 8-byte hexadecimal
variable part, which is the server random seed. The client generates
its own 8-byte random seed value, and uses both seeds to encrypt the
password. Both the encrypted password and the client random seed
value are then sent to the server for authentication. <a href="./rfc1572">RFC 1572</a> rules
will need to be adhered to when transmitting the client random seed
and substituted password values to the server. Specifically, since a
typical environment string is a variable length hexadecimal field,
the hexadecimal fields are required to be escaped and/or byte stuffed
according to the <a href="./rfc854">RFC 854</a> [<a href="#ref-8" title=""Telnet Protocol Specification"">8</a>], where any single byte could be mis-
construed as a Telnet IAC or other Telnet option negotiation control
character. The client must escape and/or byte stuff any bytes which
could be seen as a <a href="./rfc1572">RFC 1572</a> [<a href="#ref-13" title=""Telnet Environment Option"">13</a>] option, specifically VAR, VALUE, ESC
and USERVAR.
<span class="grey">Murphy, et al. Informational [Page 9]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-10" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
The following illustrates the encrypted case:
AS/400 Telnet server Enhanced Telnet client
-------------------------- -------------------------------
IAC DO NEW-ENVIRON -->
<-- IAC WILL NEW-ENVIRON
IAC SB NEW-ENVIRON SEND
USERVAR "IBMRSEEDxxxxxxxx"
USERVAR "IBMSUBSPW"
VAR USERVAR IAC SE -->
IAC SB NEW-ENVIRON IS
VAR "USER" VALUE "DUMMYUSR"
USERVAR "IBMRSEED" VALUE "yyyyyyyy"
USERVAR "IBMSUBSPW" VALUE "zzzzzzzz"
<-- IAC SE
.
.
(other negotiations) .
In this example, "xxxxxxxx" is an 8-byte hexadecimal random server
seed, "yyyyyyyy" is an 8-byte hexadecimal random client seed and
"zzzzzzzz" is an 8-byte hexadecimal encrypted password. If the
password is not valid, then the sign-on panel is displayed. If the
password is expired, then the Change Password panel is displayed.
Actual bytes transmitted in the above example are shown in hex below,
where the server seed is "7D3E488F18080404", the client seed is
"4E4142334E414233" and the encrypted password is "DFB0402F22ABA3BA".
The user profile used to generate the encrypted password is
"44554D4D59555352" (DUMMYUSR), with a clear-text password of
"44554D4D595057" (DUMMYPW).
AS/400 Telnet server Enhanced Telnet client
-------------------------- -------------------------
FF FD 27 -->
<-- FF FB 27
FF FA 27 01 03 49 42 4D
52 53 45 45 44 7D 3E 48
8F 18 08 04 04 03 49 42
4D 53 55 42 53 50 57 03
00 FF F0 -->
FF FA 27 00 00 55 53 45
52 01 44 55 4D 4D 59 55
53 52 03 49 42 4D 52 53
45 45 44 01 4E 41 42 33
4E 41 42 33 03 49 42 4D
<span class="grey">Murphy, et al. Informational [Page 10]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-11" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
53 55 42 53 50 57 01 DF
B0 40 2F 22 AB A3 BA FF
<-- F0
The following illustrates the clear-text case:
AS/400 Telnet server Enhanced Telnet client
-------------------------- -------------------------
IAC DO NEW-ENVIRON -->
<-- IAC WILL NEW-ENVIRON
IAC SB NEW-ENVIRON SEND
USERVAR "IBMRSEEDxxxxxxxx"
USERVAR "IBMSUBSPW"
VAR USERVAR IAC SE -->
IAC SB NEW-ENVIRON IS
VAR "USER" VALUE "DUMMYUSR"
USERVAR "IBMRSEED" VALUE
USERVAR "IBMSUBSPW" VALUE "yyyyyyyy"
<-- IAC SE
.
.
(other negotiations) .
In this example, "xxxxxxxx" is an 8-byte hexadecimal random server
seed, "yyyyyyyyyy" is a 10-byte us-ascii client clear-text password.
If the password has expired, then the sign-on panel is displayed.
Actual bytes transmitted in the above example are shown in hex below,
where the server seed is "7D3E488F18080404", the client seed is empty
and the clear-text password is "44554D4D595057" (DUMMYPW). The user
profile used is "44554D4D59555352" (DUMMYUSR).
AS/400 Telnet server Enhanced Telnet client
-------------------------- -------------------------
FF FD 27 -->
<-- FF FB 27
FF FA 27 01 03 49 42 4D
52 53 45 45 44 7D 3E 48
8F 18 08 04 04 03 49 42
4D 53 55 42 53 50 57 03
00 FF F0 -->
FF FA 27 00 00 55 53 45
52 01 44 55 4D 4D 59 55
53 52 03 49 42 4D 52 53
45 45 44 01 03 49 42 4D
53 55 42 53 50 57 01 44
<-- 55 4D 4D 59 50 57 FF F0
<span class="grey">Murphy, et al. Informational [Page 11]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-12" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
<span class="h3"><a class="selflink" id="section-5.1" href="#section-5.1">5.1</a> Password Substitutes Processing</span>
Both APPC and Client Access use well-known DES encryption algorithms
to create encrypted passwords. A Network Station or Enhanced Client
can generate compatible encrypted passwords if they follow these
steps, details of which can be found in the Federal Information
Processing Standards 46-2 [<a href="#ref-17" title="January 22">17</a>].
1. Padded_PW = Left justified user password padded to the right with
'40'X to 8 bytes.
The users password must be left justified in an 8 byte variable
and padded to the right with '40'X up to an 8 byte length. If the
users password is 8 bytes in length, no padding would occur. For
computing password substitutes for passwords of length 9 and 10
see section "Handling passwords of length 9 and 10" below.
Passwords less than 1 byte or greater than 10 bytes in length are
not valid. Please note, if password is not in EBCDIC, it must be
converted to EBCDIC uppercase.
2. XOR_PW = Padded_PW xor '5555555555555555'X
The padded password is Exclusive OR'ed with 8 bytes of '55'X.
3. SHIFT_RESULT = XOR_PW << 1
The entire 8 byte result is shifted 1 bit to the left; the
leftmost bit value is discarded, and the rightmost bit value is
cleared to 0.
4. PW_TOKEN = DES_ECB_mode(SHIFT_RESULT, /* key */
userID_in_EBCDIC_uppercase /* data */ )
This shifted result is used as key to the Data Encryption Standard
(Federal Information Processing Standards 46-2 [<a href="#ref-17" title="January 22">17</a>]) to encipher
the user identifier. When the user identifier is less than 8
bytes, it is left justified in an 8 byte variable and padded to
the right with '40'X. When the user identifier is 9 or 10 bytes,
it is first padded to the right with '40'X to a length of 10
bytes. Then bytes 9 and 10 are "folded" into bytes 1-8 using the
following algorithm:
Bit 0 is the high-order bit (i.e. has value of '80'X).
Byte 1, bits 0 and 1 are replaced with byte 1, bits 0 and 1
Exclusive OR'ed with byte 9, bits 0 and 1.
Byte 2, bits 0 and 1 are replaced with byte 2, bits 0 and 1
Exclusive OR'ed with byte 9, bits 2 and 3.
<span class="grey">Murphy, et al. Informational [Page 12]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-13" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
Byte 3, bits 0 and 1 are replaced with byte 3, bits 0 and 1
Exclusive OR'ed with byte 9, bits 4 and 5.
Byte 4, bits 0 and 1 are replaced with byte 4, bits 0 and 1
Exclusive OR'ed with byte 9, bits 6 and 7.
Byte 5, bits 0 and 1 are replaced with byte 5, bits 0 and 1
Exclusive OR'ed with byte 10, bits 0 and 1.
Byte 6, bits 0 and 1 are replaced with byte 6, bits 0 and 1
Exclusive OR'ed with byte 10, bits 2 and 3.
Byte 7, bits 0 and 1 are replaced with byte 7, bits 0 and 1
Exclusive OR'ed with byte 10, bits 4 and 5.
Byte 8, bits 0 and 1 are replaced with byte 8, bits 0 and 1
Exclusive OR'ed with byte 10, bits 6 and 7.
User identifier greater than 10 bytes or less than 1 byte are not
the result of this encryption id known as PW_TOKEN in the paper.
5. Increment PWSEQs and store it.
Each LU must maintain a pair of sequence numbers for ATTACHs sent
and received on each session. Each time an ATTACH is generated,
(and password substitutes are in use on the session) the sending
sequence number, PWSEQs, is incremented and saved for the next
time. Both values are set to zero at BIND time. So the first use
of PWSEQs has the value of 1, and increases by one with each use.
A new field is added to the ATTACH to carry this sequence number.
However, in certain error conditions, it is possible for the
sending side to increment the sequence number and the receiver may
not increment it. When the sender sends a subsequent ATTACH, the
receiver will detect a missing sequence. This is allowed.
However the sequence number received must always be larger than
the previous one, even if some are missing.
The maximum number of consecutive missing sequence numbers allowed
is 16. If this is exceeded, the session is unbound with a
protocol violation.
Note: The sequence number must be incremented for every ATTACH
sent. However, the sequence number field is only required to be
included in the FMH5 if a password substitute is sent (byte 4, bit
3 on).
6. RDrSEQ = RDr + PWSEQs /* RDr is server seed. */
The current value of PWSEQs is added to RDr, the random value
received from the partner LU on this session, yielding RDrSEQ,
essentially a predictably modified value of the random value
received from the partner LU at BIND time.
<span class="grey">Murphy, et al. Informational [Page 13]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-14" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
7. PW_SUB = DES_CBC_mode(PW_TOKEN, /* key */
(RDrSEQ, /* 8 bytes */
RDs, /* 8 bytes */
ID xor RDrSEQ, /* 16 bytes */
PWSEQs, /* 8 bytes */
) /* data */
)
The PW_TOKEN is used as a key to the DES function to generate
a 8 bytes value for the following string of inputs. The DES
CBC mode Initialization Vector (IV) used is 8 bytes of '00'X.
RDrSEQ: the random data value received from the partner LU
plus the sequence number.
RDs: the random data value sent to the partner LU on BIND
for this session.
A 16 byte value created by:
- padding the user identifier with '40'X to a
length of 16 bytes.
- Exclusive OR the two 8 byte halves of the padded
user identifier with the RDrSEQ value.
Note: User ID must first be converted to EBCDIC
upper case.
PWSEQs: the sequence number.
This is similar to the process used on LU-LU verification as
described in the Enhanced LU-LU Bind Security. The resulting
enciphered random data is the 'password substitute'.
<span class="h3"><a class="selflink" id="section-5.2" href="#section-5.2">5.2</a> Handling passwords of length 9 and 10</span>
1. Generate PW_TOKENa by using characters 1 to 8 of the password and
steps 1-4 from the previous section.
2. Generate PW_TOKENb by using characters 9 and 10 and steps 1-4 from
the previous section. In this case Padded_PW from step 1 will be
characters 9 and 10 padded to the right with '40'X, for a total
length of 8.
3. PW_TOKEN = PW_TOKENa xor PW_TOKENb
<span class="grey">Murphy, et al. Informational [Page 14]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-15" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
4. Now compute PW_SUB by performing steps 5-7 from the previous
section.
<span class="h3"><a class="selflink" id="section-5.3" href="#section-5.3">5.3</a> Example Password Substitute Calculation</span>
ID: USER123
Password: ABCDEFG
Server seed: '7D4C2319F28004B2'X
Client seed: '08BEF662D851F4B1'X
PWSEQs: 1 (PWSEQs is a sequence number needed in the
7-step encryption, and it is always one)
Encrypted Password should be : '5A58BD50E4DD9B5F'X
<span class="h2"><a class="selflink" id="section-6" href="#section-6">6</a>. Device Name Collision Processing</span>
Device name collision occurs when a Telnet client sends the Telnet
server a virtual device name that it wants to use, but that device is
already in use on the server. When this occurs, the Telnet server
sends a request to the client asking it to try another device name.
The environment option negotiation uses the USERVAR name of DEVNAME
to communicate the virtual device name. The following shows how the
Telnet server will request the Telnet client to send a different
DEVNAME when device name collision occurs.
AS/400 Telnet server Enhanced Telnet client
-------------------------- -------------------------
IAC SB NEW-ENVIRON SEND
VAR USERVAR IAC SE -->
Server requests all environment variables be sent.
IAC SB NEW-ENVIRON IS USERVAR
"DEVNAME" VALUE "MYDEVICE1"
USERVAR "xxxxx" VALUE "xxx"
...
<-- IAC SE
Client sends all environment variables, including DEVNAME. Server
tries to select device MYDEVICE1. If the device is already in use,
server requests DEVNAME be sent again.
IAC SB NEW-ENVIRON SEND
USERVAR "DEVNAME" IAC SE -->
<span class="grey">Murphy, et al. Informational [Page 15]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-16" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
Server sends a request for a single environment variable: DEVNAME
IAC SB NEW-ENVIRON IS USERVAR
<-- "DEVNAME" VALUE "MYDEVICE2" IAC SE
Client sends one environment variable, calculating a new value of
MYDEVICE2. If MYDEVICE2 is different from the last request, then
server tries to select device MYDEVICE2, else server disconnects
client. If MYDEVICE2 is also in use, server will send DEVNAME
request again, and keep doing so until it receives a device that is
not in use, or the same device name twice in row.
<span class="h2"><a class="selflink" id="section-7" href="#section-7">7</a>. Enhanced Printer Emulation Support</span>
<a href="./rfc1572">RFC 1572</a> style USERVAR variables have been defined to allow a
compliant Telnet client more control over the Telnet server virtual
device on the AS/400. These USERVAR's allow the client Telnet to
select a previously created virtual device or auto-create a new
virtual device with requested attributes.
This makes the enhancements available to any Telnet client that
chonoses to support the new negotiations.
The USERVAR's defined to accomplish this are:
USERVAR VALUE EXAMPLE DESCRIPTION
------------- ---------------- ---------------- -------------------
DEVNAME us-ascii char(x) PRINTER1 Printer device name
IBMIGCFEAT us-ascii char(6) 2424J0 IGC feature (DBCS)
IBMMSGQNAME us-ascii char(x) QSYSOPR *MSGQ name
IBMMSGQLIB us-ascii char(x) QSYS *MSGQ library
IBMFONT us-ascii char(x) 12 Font
IBMFORMFEED us-ascii char(1) C | U | A Formfeed
IBMTRANSFORM us-ascii char(1) 1 | 0 Transform
IBMMFRTYPMDL us-ascii char(x) *IBM42023 Mfg. type and model
IBMPPRSRC1 binary(1) 1-byte hex field Paper source 1
IBMPPRSRC2 binary(1) 1-byte hex field Paper source 2
IBMENVELOPE binary(1) 1-byte hex field Envelope hopper
IBMASCII899 us-ascii char(1) 1 | 0 ASCII 899 support
IBMWSCSTNAME us-ascii char(x) *NONE WSCST name
IBMWSCSTLIB us-ascii char(x) *LIBL WSCST library
x - up to a maximum of 10 characters
The "IBM" prefix on the USERVAR's denotes AS/400 specific attributes.
The DEVNAME USERVAR is used both for displays and printers. The
IBMFONT and IBMASCII899 are used only for SBCS environments.
<span class="grey">Murphy, et al. Informational [Page 16]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-17" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
For a description of most of these parameters (drop the "IBM" from
the USERVAR) and their permissible values, refer to Chapter 8 in the
Communications Configuration Reference [<a href="#ref-5" title=""AS/400 Communications Configuration"">5</a>].
The IBMIGCFEAT supports the following variable DBCS language
identifiers in position 5 (positions 1-4 must be '2424', position 6
must be '0'):
'J' = Japanese 'K' = Korean
'C' = Traditional Chinese 'S' = Simplified Chinese
The IBMTRANSFORM and IBMASCII899 values correspond to:
'1' = Yes '2' = No
The IBMFORMFEED values correspond to:
'C' = Continuous 'U' = Cut 'A' = Autocut
The IBMPPRSRC1, IBMPPRSRC2 and IBMENVELOPE custom USERVAR's do not
map directly to their descriptions in Chapter 8 in the Communications
Configuration Reference [<a href="#ref-5" title=""AS/400 Communications Configuration"">5</a>]. To map these, use the index listed
here:
IBMPPRSRC1 HEX IBMPPRSRC2 HEX IBMENVELOPE HEX
---------- ----- ---------- ----- ----------- -----
*NONE 'FF'X *NONE 'FF'X *NONE 'FF'X
*MFRTYPMDL '00'X *MFRTYPMDL '00'X *MFRTYPMDL '00'X
*LETTER '01'X *LETTER '01'X *B5 '06'X
*LEGAL '02'X *LEGAL '02'X *MONARCH '09'X
*EXECUTIVE '03'X *EXECUTIVE '03'X *NUMBER9 '0A'X
*A4 '04'X *A4 '04'X *NUMBER10 '0B'X
*A5 '05'X *A5 '05'X *C5 '0C'X
*B5 '06'X *B5 '06'X *DL '0D'X
*CONT80 '07'X *CONT80 '07'X
*CONT132 '08'X *CONT132 '08'X
*A3 '0E'X *A3 '0E'X
*B4 '0F'X *B4 '0F'X
*LEDGER '10'X *LEDGER '10'X
Note 1: For IBMPPRSRC2, *CONT80 and *CONT132 support starts at V3R7.
Note 2: For IBMPPRSRC1 and IBMPPRSRC2, *A3, *B4 and *LEDGER support
starts at V3R7.
<span class="grey">Murphy, et al. Informational [Page 17]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-18" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
<span class="h2"><a class="selflink" id="section-8" href="#section-8">8</a>. Telnet Printer Terminal Types</span>
New Telnet options are defined for the printer pass-through mode of
operation. To enable printer pass-through mode, both the client and
server must agree to at least support the Transmit-Binary, End-Of-
Record, and Terminal-Type Telnet options. The following are new
terminal types for printers:
TERMINAL-TYPE DESCRIPTION
------------- -------------------
IBM-5553-B01 Double-Byte printer
IBM-3812-1 Single-Byte printer
Specific characteristics of the IBM-5553-B01 or IBM-3812-1 printers
are specified through the USERVAR IBMMFRTYPMDL, which specifies the
manufacturer type and model.
An example of a typical negotiation process to establish printer
pass-through mode of operation is shown below. In this example, the
server initiates the negotiation by sending the DO TERMINAL-TYPE
request.
For DBCS environments, if IBMTRANSFORM is set to 1 (use Host Print
Transform), then the virtual device created is 3812, not 5553.
Therefore, IBM-3812-1 should be negotiated for TERMINAL-TYPE, and not
IBM-5553-B01.
AS/400 Telnet server Enhanced Telnet client
-------------------------- --------------------------
IAC DO NEW-ENVIRON -->
<-- IAC WILL NEW-ENVIRON
IAC SB NEW-ENVIRON SEND
VAR USERVAR IAC SE -->
IAC SB NEW-ENVIRON IS
USERVAR "DEVNAME" VALUE "PCPRINTER"
USERVAR "IBMMSGQNAME" VALUE "QSYSOPR"
USERVAR "IBMMSGQLIB" VALUE "*LIBL"
USERVAR "IBMTRANSFORM" VALUE "0"
USERVAR "IBMFONT" VALUE "12"
USERVAR "IBMFORMFEED" VALUE "C"
USERVAR "IBMPPRSRC1" VALUE ESC '01'X
USERVAR "IBMPPRSRC2" VALUE '04'X
USERVAR "IBMENVELOPE" VALUE IAC 'FF'X
<-- IAC SE
IAC DO TERMINAL-TYPE -->
<-- IAC WILL TERMINAL-TYPE
IAC SB TERMINAL-TYPE SEND
IAC SE -->
<span class="grey">Murphy, et al. Informational [Page 18]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-19" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
IAC SB TERMINAL-TYPE IS IBM-3812-1
<-- IAC SE
IAC DO BINARY -->
<-- IAC WILL BINARY
IAC DO EOR -->
<-- IAC WILL EOR
Some points about the above example. The IBMPPRSRC1 value requires
escaping the value using ESC according to <a href="./rfc1572">RFC 1572</a> [<a href="#ref-13" title=""Telnet Environment Option"">13</a>]. The
IBMPPRSRC2 does not require an ESC character since '04'X has no
conflict with <a href="./rfc1572">RFC 1572</a> options. Finally, to send 'FF'X for the
IBMENVELOPE value, escape the 'FF'X value by using another 'FF'X
(called "doubling"), so as not to have the value interpreted as a
Telnet character per <a href="./rfc854">RFC 854</a> [<a href="#ref-8" title=""Telnet Protocol Specification"">8</a>].
Actual bytes transmitted in the above example are shown in hex below.
AS/400 Telnet server Enhanced Telnet client
-------------------------- --------------------------
FF FD 27 -->
<-- FF FB 27
FF FA 27 01 00 03 FF F0 -->
FF FA 27 00 03 44 45 56
4E 41 4D 45 01 50 43 50
52 49 4E 54 45 52 03 49
42 4D 4D 53 47 51 4E 41
4D 45 01 51 53 59 53 4F
50 52 03 49 42 4D 4D 53
47 51 4C 49 42 01 2A 4C
49 42 4C 03 49 42 4D 54
52 41 4E 53 46 4F 52 4D
01 30 03 49 42 4D 46 4F
4E 54 01 31 32 03 49 42
4D 46 4F 52 4D 46 45 45
44 01 43 03 49 42 4D 50
50 52 53 52 43 31 01 02
01 03 49 42 4D 50 50 52
53 52 43 32 01 04 03 49
42 4D 45 4E 56 45 4C 4F
<-- 50 45 01 FF FF FF F0
FF FD 18 -->
<-- FF FB 18
FF FA 18 01 FF F0 -->
FF FA 18 00 49 42 4D 2D
<-- 33 38 31 32 2D 31 FF F0
FF FD 00 -->
<-- FF FB 00
FF FD 19 -->
<span class="grey">Murphy, et al. Informational [Page 19]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-20" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
FF FB 19
<span class="h2"><a class="selflink" id="section-9" href="#section-9">9</a>. Telnet Printer Startup Response Record for Printer Emulators</span>
Once Telnet negotiation for a 5250 pass-through mode is completed,
the 5250 Telnet server will initiate a virtual printer power-on
sequence on behalf of the Telnet client. The Telnet server will
supply a Startup Response Record to the Telnet client with the status
of the printer power-on sequence, indicating success or failure of
the virtual printer power-on sequence.
This section shows an example of two Startup Response Records. The
source device is a type 3812 model 01 printer with name "PCPRINTER"
on the target system "TARGET".
Figure 1 shows an example of a successful response; Figure 2 shows an
example of an error response.
<span class="h3"><a class="selflink" id="section-9.1" href="#section-9.1">9.1</a> Example of a Success Response Record</span>
The response record in Figure 1 was sent by an AS/400 at Release
V4R2. It is an example of the target sending back a successful
Startup Response Record.
+------------------------------------------------------------------+
| +----- Pass-Through header |
| | +--- Response data |
| | | +---- Start diagnostic information|
| | | | |
| +----------++----------++--------------------------------------- |
| | || || |
| 004912A090000560060020C0003D0000C9F9F0F2E3C1D9C7C5E34040D7C3D7D9 |
| | | T A R G E T P C P R |
| +------+ |
| Response Code (I902) |
| |
| ---------------------------------------------------------------- |
| |
| C9D5E3C5D9400000000000000000000000000000000000000000000000000000 |
| I N T E R |
| |
| +------- End of diagnostic information |
| | |
| -----------------+ |
| | |
| 000000000000000000 |
+------------------------------------------------------------------+
Figure 1. Example of a success response record.
<span class="grey">Murphy, et al. Informational [Page 20]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-21" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
- '0049'X = Length pass-through data, including this length field
- '12A0'X = GDS LU6.2 header
- '90000560060020C0003D0000'X = Fixed value fields
- 'C9F9F0F2'X = Response Code (I902)
- 'E3C1D9C7C5E34040'X = System Name (TARGET)
- 'D7C3D7D9C9D5E3C5D940'X = Object Name (PCPRINTER)
<span class="h3"><a class="selflink" id="section-9.2" href="#section-9.2">9.2</a> Example of an Error Response Record</span>
The response record in Figure 2 is one that reports an error. The
virtual device named "PCPRINTER", is not available on the target
system "TARGET", because the device is not available. You would
normally see this error if the printer was already assigned to
another Telnet session.
+------------------------------------------------------------------+
| +----- Pass-Through header |
| | +--- Response data |
| | | +---- Start diagnostic information|
| | | | |
| +----------++----------++--------------------------------------- |
| | || || |
| 004912A09000056006008200003D0000F8F9F0F2E3C1D9C7C5E34040D7C3D7D9 |
| | | T A R G E T P C P R |
| +------+ |
| Response Code (8902) |
| |
| ---------------------------------------------------------------- |
| |
| C9D5E3C5D9400000000000000000000000000000000000000000000000000000 |
| I N T E R |
| |
| +------- End of diagnostic information |
| | |
| -----------------+ |
| | |
| 000000000000000000 |
+------------------------------------------------------------------+
Figure 2. Example of an error response record.
- '0049'X = Length pass-through data, including this length field
- '12A0'X = GDS LU6.2 header
- '90000560060020C0003D0000'X = Fixed value fields
- 'F8F9F0F2'X = Response Code (8902)
- 'E3C1D9C7C5E34040'X = System Name (TARGET)
- 'D7C3D7D9C9D5E3C5D940'X = Object Name (PCPRINTER)
<span class="grey">Murphy, et al. Informational [Page 21]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-22" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
<span class="h3"><a class="selflink" id="section-9.3" href="#section-9.3">9.3</a> Response Codes</span>
The Start-Up Response Record success response codes:
CODE DESCRIPTION
---- ------------------------------------------------------
I901 Virtual device has less function than source device
I902 Session successfully started
I906 Automatic sign-on requested, but not allowed.
Session still allowed; a sign-on screen will be
coming.
The Start-Up Response Record error response codes:
CODE DESCRIPTION
---- ------------------------------------------------------
2702 Device description not found.
2703 Controller description not found.
2777 Damaged device description.
8901 Device not varied on.
8902 Device not available.
8903 Device not valid for session.
8906 Session initiation failed.
8907 Session failure.
8910 Controller not valid for session.
8916 No matching device found.
8917 Not authorized to object.
8918 Job canceled.
8920 Object partially damaged.
8921 Communications error.
8922 Negative response received.
8923 Start-up record built incorrectly.
8925 Creation of device failed.
8928 Change of device failed.
8929 Vary on or vary off failed.
8930 Message queue does not exist.
8934 Start-up for S/36 WSF received.
8935 Session rejected.
8936 Security failure on session attempt.
8937 Automatic sign-on rejected.
8940 Automatic configuration failed or not allowed.
I904 Source system at incompatible release.
<span class="grey">Murphy, et al. Informational [Page 22]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-23" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
<span class="h2"><a class="selflink" id="section-10" href="#section-10">10</a>. Printer Steady-State Pass-Through Interface</span>
The information in this section applies to the passthrough session
after the receipt of startup confirmation records is complete.
Following is the printer header interface used by Telnet.
+------------------------------------------------------------------+
| +-- Length of structure (LLLL) |
| | |
| | +-- GDS identifier |
| | | |
| | | +-- Data flow record |
| | | | |
| | | | +-- Length of pass-through specific header (LL) |
| | | | | |
| | | | | +-- Flags |
| | | | | | |
| | | | | | +-- Printer operation code |
| | | | | | | |
| | | | | | | +-- Diagnostic field - zero pad to|
| | | | | | | | LL specified |
| | | | | | | | |
| | | | | | | | +-- Printer data |
| | | | | | | | | |
| +--+ +--+ +--+ ++ +--+ ++ +----------+ +----------------+ |
| | | | | | | || | | || | | | | |
| xxxx 12A0 xxxx xx xxxx xx xxxxxxxxxxxx ... print data ... |
| |
+------------------------------------------------------------------+
Figure 3. Layout of the printer pass-through header
BYTES 0-1: Length of structure including this field (LLLL)
BYTES 2-3: GDS Identifier ('12A0'X)
BYTE 4-5: Data flow record
This field contains flags that describe what type of
data pass-through should expect to find following this
header. Generally, bits 0-2 in the first byte are
mutually exclusive (that is, if one of them is set to '
1'B, the rest will be set to '0'B.) The bits, and their
meanings follow.
<span class="grey">Murphy, et al. Informational [Page 23]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-24" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
BIT DESCRIPTION
0 Start-Up confirmation
1 Termination record
2 Start-Up Record
3 Diagnostic information included
4 - 5 Reserved
6 Reserved
7 Printer record
8 - 13 Reserved
14 Client-originated (inbound) printer record
15 Server-originated (outbound) printer record
BYTE 6: Length printer pass-through header including this
field (LL)
BYTES 7-8: Flags
BYTE 7 BITS: xxxx x111 --> Reserved
xxxx 1xxx --> Last of chain
xxx1 xxxx --> First of chain
xx1x xxxx --> Printer now ready
x1xx xxxx --> Intervention Required
1xxx xxxx --> Error Indicator
BYTE 8 BITS: xxxx xxxx --> Reserved
BYTE 9: Printer operation code
'01'X Print/Print complete
'02'X Clear Print Buffers
BYTE 10-LL: Diagnostic information (1)
If BYTE 7 = xx1x xxxx then bytes 10-LL may contain:
Printer ready C9 00 00 00 02
If BYTE 7 = x1xx xxxx then bytes 10-LL may contain: (2)
Command/parameter not valid C9 00 03 02 2x
Print check C9 00 03 02 3x
Forms check C9 00 03 02 4x
Normal periodic condition C9 00 03 02 5x
Data stream error C9 00 03 02 6x
Machine/print/ribbon check C9 00 03 02 8x
If BYTE 7 = 1xxx xxxx then bytes 10-LL may contain: (3)
Cancel 08 11 02 00
Invalid print parameter 08 11 02 29
<span class="grey">Murphy, et al. Informational [Page 24]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-25" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
Invalid print command 08 11 02 28
Diagnostic information notes:
1. LL is the length of the structure defined in Byte 6. If no
additional data is present, the remainder of the structure must
be padded with zeroes.
2. These are printer SIGNAL commands. Further information on these
commands may be obtained from the 5494 Remote Control Unit
Functions Reference guide [<a href="#ref-2" title=""5494 Remote Control Unit, Functions Reference"">2</a>]. Refer to your AS/400 printer
documentation for more specific information on these data stream
exceptions. Some 3812 and 5553 errors that may be seen:
Machine check C9 00 03 02 11
Graphics check C9 00 03 02 26
Print check C9 00 03 02 31
Form jam C9 00 03 02 41
Paper jam C9 00 03 02 47
End of forms C9 00 03 02 50
Printer not ready C9 00 03 02 51
Data stream - class 1 C9 00 03 02 66 loss of text
Data stream - class 2 C9 00 03 02 67 text appearance
Data stream - class 3 C9 00 03 02 68 multibyte control error
Data stream - class 4 C9 00 03 02 69 multibyte control parm
Cover unexpectedly open C9 00 03 02 81
Machine check C9 00 03 02 86
Machine check C9 00 03 02 87
Ribbon check C9 00 03 02 88
3. These are printer negative responses. Further information on
these commands may be obtained from the 5494 Remote Control Unit
Functions Reference guide [<a href="#ref-2" title=""5494 Remote Control Unit, Functions Reference"">2</a>].
The print data will start in byte LL+1.
<span class="h3"><a class="selflink" id="section-10.1" href="#section-10.1">10.1</a> Example of a Print Record</span>
Figure 4 shows the server sending the client data with a print
record. This is normally seen following receipt of a Success
Response Record, such as the example in Figure 1.
<span class="grey">Murphy, et al. Informational [Page 25]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-26" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
+--------------------------------------------------------------------+
| +-- Length of structure (LLLL) |
| | +-- GDS identifier |
| | | +-- Data flow record |
| | | | +-- Length of pass-through specific header (LL) |
| | | | | +-- Flags |
| | | | | | +-- Printer operation code |
| | | | | | | +-- Zero pad to LL specified (0A) |
| | | | | | | | +-- Printer data |
| | | | | | | | | |
| +--+ +--+ +--+ ++ +--+ ++ +----------+ +---------------------------|
| | | | | | | || | | || | | | |
| 0085 12A0 0101 0A 1800 01 000000000000 34C4012BD20345FF2BD2044C0002|
| |
| ------------------------------------------------------------ |
| |
| 2BD2040D00002BD20A8501010201030204022BD20309022BD2061100014A |
| |
| ------------------------------------------------------------ |
| |
| 402BD20601010000012BD306F60000FFFF2BD20A48000001000000010100 |
| |
| ------------------------------------------------------------ |
| |
| 2BD10705000B0090012BD2044900F02BD206404A403DE02BD2041500F034 |
| |
| end of printer data |
| -------------------------+ |
| | |
| C4012BD10381FF002BC8034001 |
+--------------------------------------------------------------------+
Figure 4. Server sending client data with a print record
- '0085'X = Logical record length, including this byte (LLLL)
- '12A0'X = GDS LU6.2 header
- '0101'X = Data flow record (server to client)
- '0A'X = Length of pass-through specific header (LL)
- '1800'X = First of chain / Last of chain indicators
- '01'X = Print
- '000000000000'X = Zero pad header to LL specified
- '34C401'X = First piece of data for spooled data
- Remainder is printer data/commands/orders
<span class="grey">Murphy, et al. Informational [Page 26]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-27" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
<span class="h3"><a class="selflink" id="section-10.2" href="#section-10.2">10.2</a> Example of a Print Complete Record</span>
Figure 5 shows the client sending the server a print complete record.
This would normally follow receipt of a print record, such as the
example in Figure 4. This indicates successful completion of a print
request.
+-------------------------------------------------------------------+
| +-- Length of structure (LLLL) |
| | +-- GDS identifier |
| | | +-- Data flow record |
| | | | +-- Length of pass-through specific header (LL) |
| | | | | +-- Flags |
| | | | | | +-- Printer operation code |
| | | | | | | |
| +--+ +--+ +--+ ++ +--+ ++ |
| | | | | | | || | | || |
| 000A 12A0 0102 04 0000 01 |
+-------------------------------------------------------------------+
Figure 5. Client sending server a print complete record
- '000A'X = Logical record length, including this byte (LLLL)
- '12A0'X = GDS LU6.2 header
- '0102'X = Data flow response record (client to server)
- '04'X = Length of pass-through specific header (LL)
- '0000'X = Good Response
- '01'X = Print Complete
<span class="h3"><a class="selflink" id="section-10.3" href="#section-10.3">10.3</a> Example of a Null Print Record</span>
Figure 6 shows the server sending the client a null print record.
The null print record is the last print command the server sends to
the client for a print job, and indicates to the printer there is no
more data. The null data byte '00'X is optional, and in some cases
may be omitted (in particular, this scenario occurs in DBCS print
streams).
This example would normally follow any number of print records, such
as the example in Figure 4. This indicates successful completion of
a print job. The client normally responds to this null print record
with another print complete record, such as in Figure 5.
<span class="grey">Murphy, et al. Informational [Page 27]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-28" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
+------------------------------------------------------------------+
| +-- Length of structure (LLLL) |
| | +-- GDS identifier |
| | | +-- Data flow record |
| | | | +-- Length of pass-through specific header (LL) |
| | | | | +-- Flags |
| | | | | | +-- Printer operation code |
| | | | | | | +-- Zero pad to LL specified (0A) |
| | | | | | | | +-- Printer data |
| | | | | | | | | |
| +--+ +--+ +--+ ++ +--+ ++ +----------+ ++ |
| | | | | | | || | | || | | || |
| 0011 12A0 0101 0A 0800 01 000000000000 00 |
+------------------------------------------------------------------+
Figure 6. Server sending client a null print record
- '0011'X = Logical record length, including this byte
- '12A0'X = GDS LU6.2 header
- '0101'X = Data flow record
- '0A'X = Length of pass-through specific header (LL)
- '0800'X = Last of Chain
- '01'X = Print
- '000000000000'X = Zero pad header to LL specified
- '00'X = Null data byte
<span class="h2"><a class="selflink" id="section-11" href="#section-11">11</a>. End-to-End Print Example</span>
The next example shows a full print exchange between a Telnet client
and server for a 526 byte spooled file. Selective translation of the
hexadecimal streams into 1) Telnet negotiations and 2) ASCII/EBCDIC
characters are done to aid readability. Telnet negotiations are
delimited by '(' and ')' parenthesis characters; ASCII/EBCDIC
conversions are bracketed by '|' vertical bar characters.
AS/400 Telnet server Enhanced Telnet client
------------------------------- ---------------------------------
FFFD27 -->
(IAC DO NEW-ENVIRON)
<-- FFFB27
(IAC WILL NEW-ENVIRON)
FFFD18FFFA270103 49424D5253454544
7EA5DFDDFD300404 0003FFF0 -->
(IAC DO TERMINAL-TYPE
IAC SB NEW-ENVIRON SEND USERVAR
<span class="grey">Murphy, et al. Informational [Page 28]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-29" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
IBMRSEED xxxxxxxx VAR USERVAR
IAC SE)
<-- FFFB18
(IAC WILL TERMINAL-TYPE)
FFFA1801FFF0 -->
(IAC SB TERMINAL-TYPE SEND IAC
SE)
FFFA27000349424D 52534545447EA5DF
DDFD300404000344 45564E414D450144
554D4D5950525403 49424D4D5347514E
414D450151535953 4F50520349424D4D
5347514C4942012A 4C49424C0349424D
464F4E5401313103 49424D5452414E53
464F524D01310349 424D4D4652545950
4D444C012A485049 490349424D505052
5352433101020103 49424D5050525352
433201040349424D 454E56454C4F5045
01FFFF0349424D41 5343494938393901
<-- 30FFF0
(IAC SB NEW-ENVIRON IS USERVAR
IBMRSEED xxxxxxxx VAR
USERVAR DEVNAME VALUE DUMMYPRT
USERVAR IBMMSGQNAME VALUE QSYSOPR
USERVAR IBMMSGQLIB VALUE *LIBL
USERVAR IBMFONT VALUE 11
USERVAR IBMTRANSFORM VALUE 1
USERVAR IBMMFRTYPMDL VALUE *HPII
USERVAR IBMPPRSRC1 VALUE ESC '01'X
USERVAR IBMPPRSRC2 VALUE '04'X
USERVAR IBMENVELOPE VALUE IAC
USERVAR IBMASCII899 VALUE 0
IAC SE)
<-- FFFA180049424D2D 333831322D31FFF0
(IAC SB TERMINAL-TYPE IS
IBM-3812-1 IAC SE)
FFFD19 -->
(IAC DO EOR)
<-- FFFB19
<span class="grey">Murphy, et al. Informational [Page 29]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-30" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
(IAC WILL EOR)
FFFB19 -->
(IAC WILL EOR)
<-- FFFD19
(IAC DO EOR)
FFFD00 -->
(IAC DO BINARY)
<-- FFFB00
(IAC WILL BINARY)
FFFB00 -->
(IAC WILL BINARY)
<-- FFFD00
(IAC DO BINARY)
004912A090000560 060020C0003D0000 | - { |
C9F9F0F2C5D3C3D9 E3D7F0F6C4E4D4D4 |I902ELCRTP06DUMM| (EBCDIC)
E8D7D9E340400000 0000000000000000 |YPRT |
0000000000000000 0000000000000000 | |
0000000000000000 00FFEF --> | |
(73-byte startup success response
record ... IAC EOR)
00DF12A001010A18 0001000000000000 | |
03CD1B451B283130 551B287330703130 | E (10U (s0p10| (ASCII)
2E30306831327630 733062303033541B |.00h12v0s0b003T |
287330421B266440 1B266C304F1B266C |(s0B &d@ &l0O &l|
303038431B266C30 3035431B28733070 |008C &l005C (s0p|
31372E3130683130 7630733062303030 |17.10h10v0s0b000|
541B283130551B28 73307031372E3130 |T (10U (s0p17.10|
6831307630733062 303030541B287330 |h10v0s0b000T (s0|
421B2664401B266C 314F1B266C303035 |B &d@ &l1O &l005|
431B287330703137 2E31306831307630 |C (s0p17.10h10v0|
733062303030541B 266C314F1B287330 |s0b000T &l1O (s0|
7031372E31306831 3076307330623030 |p17.10h10v0s0b00|
30541B2873307031 372E313068313076 |0T (s0p17.10h10v|
3073306230303054 1B266C30303543FF |0s0b000T &l005C |
EF --> | |
(... 223-byte print record ...
... first of chain ...
... last of chain ... IAC EOR)
<span class="grey">Murphy, et al. Informational [Page 30]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-31" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
<-- 000A12A001020400 0001FFEF
(10-byte print complete header)
031012A001010A10 0001000000000000 | |
03FFFF1B451B2831 30551B2873307031 | E (10U (s0p1| (ASCII)
372E313068313076 3073306230303054 |7.10h10v0s0b000T|
1B287330421B2664 401B266C314F1B26 | (s0B &d@ &l1O &|
6C303035431B266C 31481B266C314F1B |l005C &l1H &l1O |
266C3032411B266C 31431B266C303030 |&l02A &l1C &l000|
38451B266C303038 431B266C30303439 |8E &l008C &l0049|
461B266130521B26 6C303035430A0A0A |F &a0R &l005C |
0A0A0A0A1B26612B 3030303130561B26 | &a+00010V &|
6C303035431B2661 2B30303231364820 |l005C &a+00216H |
2020202020202020 2020202020202020 | |
2020202020205072 696E74204B657920 | Print Key |
4F75747075742020 2020202020202020 |Output |
2020202020202020 2020202020202020 | |
2020202020205061 6765202020310D0A | Page 1 |
1B26612B30303231 3648202020203537 | &a+00216H 57|
3639535331205634 52334D3020393830 |69SS1 V4R3M0 980|
373203FFFF392020 2020202020202020 |72 9 |
202020202020454C 4352545030362020 | ELCRTP06 |
2020202020202020 202030332F33312F | 03/31/|
3939202031363A33 303A34350D0A1B26 |99 16:30:45 &|
612B303032313648 0D0A1B26612B3030 |a+00216H &a+00|
3231364820202020 446973706C617920 |216H Display |
4465766963652020 2E202E202E202E20 |Device . . . . |
2E203A2020515041 444556303033510D |. : QPADEV003Q |
0A1B26612B303032 3136482020202055 | &a+00216H U|
73657220202E202E 202E202E202E202E |ser . . . . . .|
202E202E202E202E 203A202052434153 | . . . . : RCAS|
54524F0D0A1B2661 2B3030323136480D |TRO &a+00216H |
0A1B26612B303032 313648204D41494E | &a+00216H MAIN|
2020202020202020 2020202020202020 | |
2020202020202020 20202041532F3430 | AS/40|
30204D61696E204D 656E750D0A1B2661 |0 Main Menu &a|
2B30303203FFFF31 3648202020202020 |+002 16H |
2020202020202020 2020202020202020 | |
2020202020202020 2020202020202020 | |
2020202020202020 2020202020202020 | |
2020202020202053 797374656D3A2020 | System: |
20454C4352545030 360D0A1B26612B30 | ELCRTP06 &a+0|
3032313648205365 6C656374206F6E65 |0216H Select one|
206F662074686520 666F6C6C6F77696E | of the followin|
673A0D0A1B26612B 3030323136480D0A |g: &a+00216H |
1B26612B30303231 3648202020202020 | &a+00216H |
312E205573657220 7461736B730D0A1B |1. User tasks |
26612B3030323136 4820202020202032 |&a+00216H 2|
<span class="grey">Murphy, et al. Informational [Page 31]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-32" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
2E204F6666696365 207461736B730D0A |. Office tasks |
1B26612B30303231 36480D0A1B26612B | &a+00216H &a+|
3030323136482020 20202020342E2046 |00216H 4. F|
696C65732C206C69 627261726965732C |iles, libraries,|
20616EFFEF | an |
(... 784-byte print record ...
... first of chain ... IAC EOR)
<-- 000A12A001020400 0001FFEF
(10-byte print complete header)
020312A001010A00 0001000000000000 | |
64206603FFFF6F6C 646572730D0A1B26 |d f olders &| (ASCII)
612B303032313648 0D0A1B26612B3030 |a+00216H &a+00|
3231364820202020 2020362E20436F6D |216H 6. Com|
6D756E6963617469 6F6E730D0A1B2661 |munications &a|
2B3030323136480D 0A1B26612B303032 |+00216H &a+002|
3136482020202020 20382E2050726F62 |16H 8. Prob|
6C656D2068616E64 6C696E670D0A1B26 |lem handling &|
612B303032313648 202020202020392E |a+00216H 9.|
20446973706C6179 2061206D656E750D | Display a menu |
0A1B26612B303032 3136482020202020 | &a+00216H |
31302E20496E666F 726D6174696F6E20 |10. Information |
417373697374616E 74206F7074696F6E |Assistant option|
730D0A1B26612B30 3032313648202020 |s &a+00216H |
202031312E20436C 69656E7420416363 | 11. Client Acc|
6573732F34303020 7461736B730D0A1B |ess/400 tasks |
26612B3030323136 480D0A1B26612B30 |&a+00216H &a+0|
303231364803ED20 2020202039302E20 |0216H 90. |
5369676E206F6666 0D0A1B26612B3030 |Sign off &a+00|
323136480D0A1B26 612B303032313648 |216H &a+00216H|
2053656C65637469 6F6E206F7220636F | Selection or co|
6D6D616E640D0A1B 26612B3030323136 |mmand &a+00216|
48203D3D3D3E0D0A 1B26612B30303231 |H ===> &a+0021|
36480D0A1B26612B 3030323136482046 |6H &a+00216H F|
333D457869742020 2046343D50726F6D |3=Exit F4=Prom|
707420202046393D 5265747269657665 |pt F9=Retrieve|
2020204631323D43 616E63656C202020 | F12=Cancel |
4631333D496E666F 726D6174696F6E20 |F13=Information |
417373697374616E 740D0A1B26612B30 |Assistant &a+0|
3032313648204632 333D53657420696E |0216H F23=Set in|
697469616C206D65 6E750D0A1B26612B |itial menu &a+|
3030323136480D0A 1B26612B30303231 |00216H &a+0021|
36480D0CFFEF |6H |
(... 515-byte print record ...
IAC EOR)
<span class="grey">Murphy, et al. Informational [Page 32]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-33" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
<-- 000A12A001020400 0001FFEF
(10-byte print complete header)
001412A001010A00 0001000000000000 | |
03021B45FFEF | E | (ASCII)
(... 20-byte print record ...
IAC EOR)
<-- 000A12A001020400 0001FFEF
(10-byte print complete header)
001112A001010A08 0001000000000000
00FFEF -->
(... 17-byte NULL print record ...
... last of chain ... IAC EOR)
<-- 000A12A001020400 0001FFEF
(10-byte print complete header)
<span class="h2"><a class="selflink" id="section-12" href="#section-12">12</a>. Authors' Note</span>
Discussion of this memo should occur in one of these mailing lists:
TN3270E List (Roger Fajman raf@cu.nih.gov). Send subscription
requests as e-mail with "subscribe tn3270e your_full_name" to
listserv@list.nih.gov.
Midrange-L List (David Gibbs david@midrange.com). Send
subscription requests as email with "subscribe midrange-l
your_internet_address" to majordomo@midrange.com.
Telnet Working Group Mailing List: Send subscription requests as
email with "subscribe telnet-ietf" to telnet-ietf-
request@bsdi.com.
<span class="h2"><a class="selflink" id="section-13" href="#section-13">13</a>. References</span>
[<a id="ref-1">1</a>] IBM, "IBM 5250 Information Display System, Functions Reference
Manual", SA21-9247-6, March 1987.
[<a id="ref-2">2</a>] IBM, "5494 Remote Control Unit, Functions Reference", SC30-
3533-04, August 1995.
[<a id="ref-3">3</a>] IBM, "AS/400 System API Reference", SC41-5801-01, February
1998.
<span class="grey">Murphy, et al. Informational [Page 33]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-34" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
[<a id="ref-4">4</a>] IBM, "AS/400 TCP/IP Configuration and Reference", SC41-5420-02,
September 1998.
[<a id="ref-5">5</a>] IBM, "AS/400 Communications Configuration", SC41-5401-00,
August 1997.
[<a id="ref-6">6</a>] IBM, "SNA Formats", GA27-3136-13, November 1993.
[<a id="ref-7">7</a>] IBM, "Using the Pageprinter 3812 with System/36 or System/38",
S544-3343-01, September 1997.
[<a id="ref-8">8</a>] Postel, J. and J. Reynolds, "Telnet Protocol Specification",
STD 8, <a href="./rfc854">RFC 854</a>, May 1983.
[<a id="ref-9">9</a>] Postel, J. and J. Reynolds, "Telnet Option Specifications", STD
8, <a href="./rfc855">RFC 855</a>, May 1983.
[<a id="ref-10">10</a>] Postel, J. and J. Reynolds, "Telnet Binary Transmission", STD
27, <a href="./rfc856">RFC 856</a>, May 1983.
[<a id="ref-11">11</a>] VanBokkeln, J., "Telnet Terminal-Type Option", <a href="./rfc1091">RFC 1091</a>,
February 1989.
[<a id="ref-12">12</a>] Postel, J. and J. Reynolds, "Telnet End of Record Option", <a href="./rfc885">RFC</a>
<a href="./rfc885">885</a>, December 1983.
[<a id="ref-13">13</a>] Alexander, S., "Telnet Environment Option", <a href="./rfc1572">RFC 1572</a>, January
1994.
[<a id="ref-14">14</a>] Chmielewski, P., "5250 Telnet Interface", <a href="./rfc1205">RFC 1205</a>, February
1991.
[<a id="ref-15">15</a>] Postel, J. and J. Reynolds, "Telnet Supress Go Ahead Option",
STD 29, <a href="./rfc858">RFC 858</a>, May 1983.
[<a id="ref-16">16</a>] IBM, "AS/400 National Language Support", SC41-5101-01, February
1998.
[<a id="ref-17">17</a>] Data Encryption Standard (DES), Federal Information Processing
Standards Publication 46-2, January 22, 1988.
[<a id="ref-18">18</a>] DES Modes of Operation, Federal Information Processing
Standards Publication 81, December 1980.
[<a id="ref-19">19</a>] Reynolds, J. and J. Postel, "Assigned Numbers", STD 2, <a href="./rfc1700">RFC</a>
<a href="./rfc1700">1700</a>, October 1994.
[<a id="ref-20">20</a>] IBM, "IBM Pageprinter 3812 Programming Reference", S544-3268.
<span class="grey">Murphy, et al. Informational [Page 34]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-35" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
<span class="h2"><a class="selflink" id="section-14" href="#section-14">14</a>. Security Considerations</span>
Security considerations of passwords are discussed in <a href="#section-6">Section 6</a>.
<span class="h2"><a class="selflink" id="section-15" href="#section-15">15</a>. Authors' Addresses</span>
Thomas E. Murphy, Jr.
IBM Corporation
1701 North Street
Endicott, NY 13760
Phone: (607) 752-5482
Fax: (607) 752-5421
EMail: murphyte@us.ibm.com
Paul F. Rieth
IBM Corporation
1701 North Street
Endicott, NY 13760
Phone: (607) 752-5474
Fax: (607) 752-5421
EMail: rieth@us.ibm.com
Jeffrey S. Stevens
IBM Corporation
1701 North Street
Endicott, NY 13760
Phone: (607) 752-5488
Fax: (607) 752-5421
EMail: jssteven@us.ibm.com
<span class="h2"><a class="selflink" id="section-16" href="#section-16">16</a>. Relation to Other RFC's</span>
UPDATES
This memo is an update to <a href="./rfc1205">RFC 1205</a> [<a href="#ref-14" title=""5250 Telnet Interface"">14</a>], which describes the 5250
Telnet Interface. This update enhances that description to
include device negotiation as well as printer support.
This memo makes use of <a href="./rfc1572">RFC 1572</a> [<a href="#ref-13" title=""Telnet Environment Option"">13</a>] to enhance communications
with 5250 Telnet clients. <a href="./rfc1572">RFC 1572</a> is currently on the Standards
Track as a Proposed Standard, and is listed in Assigned Numbers
[<a href="#ref-19" title=""Assigned Numbers"">19</a>].
<span class="grey">Murphy, et al. Informational [Page 35]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-36" ></span>
<span class="grey"><a href="./rfc2877">RFC 2877</a> 5250 Telnet Enhancements July 2000</span>
<span class="h2"><a class="selflink" id="section-17" href="#section-17">17</a>. Full Copyright Statement</span>
Copyright (C) The Internet Society (2000). All Rights Reserved.
This document and translations of it may be copied and furnished to
others, and derivative works that comment on or otherwise explain it
or assist in its implementation may be prepared, copied, published
and distributed, in whole or in part, without restriction of any
kind, provided that the above copyright notice and this paragraph are
included on all such copies and derivative works. However, this
document itself may not be modified in any way, such as by removing
the copyright notice or references to the Internet Society or other
Internet organizations, except as needed for the purpose of
developing Internet standards in which case the procedures for
copyrights defined in the Internet Standards process must be
followed, or as required to translate it into languages other than
English.
The limited permissions granted above are perpetual and will not be
revoked by the Internet Society or its successors or assigns.
This document and the information contained herein is provided on an
"AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Murphy, et al. Informational [Page 36]
</pre>
|