1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2876 2877 2878 2879 2880 2881 2882 2883 2884 2885 2886 2887 2888 2889 2890 2891 2892 2893 2894 2895 2896 2897 2898 2899 2900 2901 2902 2903 2904 2905 2906 2907 2908 2909 2910 2911 2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923 2924 2925 2926 2927 2928 2929 2930 2931 2932 2933 2934 2935 2936 2937 2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981 2982 2983 2984 2985 2986 2987 2988 2989 2990 2991 2992 2993 2994 2995 2996 2997 2998 2999 3000 3001 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3013 3014 3015 3016 3017 3018 3019 3020 3021
|
<pre>Internet Engineering Task Force (IETF) J. Parello
Request for Comments: 7326 B. Claise
Category: Informational Cisco Systems, Inc.
ISSN: 2070-1721 B. Schoening
Independent Consultant
J. Quittek
NEC Europe Ltd.
September 2014
<span class="h1">Energy Management Framework</span>
Abstract
This document defines a framework for Energy Management (EMAN) for
devices and device components within, or connected to, communication
networks. The framework presents a physical reference model and
information model. The information model consists of an Energy
Management Domain as a set of Energy Objects. Each Energy Object can
be attributed with identity, classification, and context. Energy
Objects can be monitored and controlled with respect to power, Power
State, energy, demand, Power Attributes, and battery. Additionally,
the framework models relationships and capabilities between Energy
Objects.
Status of This Memo
This document is not an Internet Standards Track specification; it is
published for informational purposes.
This document is a product of the Internet Engineering Task Force
(IETF). It represents the consensus of the IETF community. It has
received public review and has been approved for publication by the
Internet Engineering Steering Group (IESG). Not all documents
approved by the IESG are a candidate for any level of Internet
Standard; see <a href="./rfc5741#section-2">Section 2 of RFC 5741</a>.
Information about the current status of this document, any errata,
and how to provide feedback on it may be obtained at
<a href="http://www.rfc-editor.org/info/rfc7326">http://www.rfc-editor.org/info/rfc7326</a>.
<span class="grey">Parello, et al. Informational [Page 1]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-2" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Copyright Notice
Copyright (c) 2014 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to <a href="https://www.rfc-editor.org/bcp/bcp78">BCP 78</a> and the IETF Trust's Legal
Provisions Relating to IETF Documents
(<a href="http://trustee.ietf.org/license-info">http://trustee.ietf.org/license-info</a>) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Table of Contents
<a href="#section-1">1</a>. Introduction ....................................................<a href="#page-3">3</a>
<a href="#section-2">2</a>. Terminology .....................................................<a href="#page-4">4</a>
<a href="#section-3">3</a>. Target Devices ..................................................<a href="#page-9">9</a>
<a href="#section-4">4</a>. Physical Reference Model .......................................<a href="#page-10">10</a>
<a href="#section-5">5</a>. Areas Not Covered by the Framework .............................<a href="#page-11">11</a>
<a href="#section-6">6</a>. Energy Management Abstraction ..................................<a href="#page-12">12</a>
<a href="#section-6.1">6.1</a>. Conceptual Model ..........................................<a href="#page-12">12</a>
<a href="#section-6.2">6.2</a>. Energy Object (Class) .....................................<a href="#page-13">13</a>
<a href="#section-6.3">6.3</a>. Energy Object Attributes ..................................<a href="#page-15">15</a>
<a href="#section-6.4">6.4</a>. Measurements ..............................................<a href="#page-18">18</a>
<a href="#section-6.5">6.5</a>. Control ...................................................<a href="#page-19">19</a>
<a href="#section-6.6">6.6</a>. Relationships .............................................<a href="#page-25">25</a>
<a href="#section-7">7</a>. Energy Management Information Model ............................<a href="#page-29">29</a>
<a href="#section-8">8</a>. Modeling Relationships between Devices .........................<a href="#page-33">33</a>
<a href="#section-8.1">8.1</a>. Power Source Relationship .................................<a href="#page-33">33</a>
<a href="#section-8.2">8.2</a>. Metering Relationship .....................................<a href="#page-37">37</a>
<a href="#section-8.3">8.3</a>. Aggregation Relationship ..................................<a href="#page-38">38</a>
<a href="#section-9">9</a>. Relationship to Other Standards ................................<a href="#page-39">39</a>
<a href="#section-10">10</a>. Security Considerations .......................................<a href="#page-39">39</a>
<a href="#section-10.1">10.1</a>. Security Considerations for SNMP .........................<a href="#page-40">40</a>
<a href="#section-11">11</a>. IANA Considerations ...........................................<a href="#page-41">41</a>
<a href="#section-11.1">11.1</a>. IANA Registration of New Power State Sets ................<a href="#page-41">41</a>
<a href="#section-11.2">11.2</a>. Updating the Registration of Existing Power State Sets ...<a href="#page-42">42</a>
<a href="#section-12">12</a>. References ....................................................<a href="#page-43">43</a>
<a href="#section-12.1">12.1</a>. Normative References .....................................<a href="#page-43">43</a>
<a href="#section-12.2">12.2</a>. Informative References ...................................<a href="#page-44">44</a>
<a href="#section-13">13</a>. Acknowledgments ...............................................<a href="#page-45">45</a>
<a href="#appendix-A">Appendix A</a>. Information Model Listing .............................<a href="#page-46">46</a>
<span class="grey">Parello, et al. Informational [Page 2]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-3" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
<span class="h2"><a class="selflink" id="section-1" href="#section-1">1</a>. Introduction</span>
Network Management is often divided into the five main areas defined
in the ISO Telecommunications Management Network model: Fault,
Configuration, Accounting, Performance, and Security Management
(FCAPS) [<a href="#ref-X.700" title=""Management framework for Open Systems Interconnection (OSI) for CCITT applications"">X.700</a>]. Not covered by this traditional management model is
Energy Management, which is rapidly becoming a critical area of
concern worldwide, as seen in [<a href="#ref-ISO50001" title=""ISO 50001:2011 Energy management systems -- Requirements with guidance for use"">ISO50001</a>].
This document defines an Energy Management framework for devices
within, or connected to, communication networks, per the Energy
Management requirements specified in [<a href="./rfc6988" title=""Requirements for Energy Management"">RFC6988</a>]. The devices, or the
components of these devices (such as line cards, fans, and disks),
can then be monitored and controlled. Monitoring includes measuring
power, energy, demand, and attributes of power. Energy Control can
be performed by setting a device's or component's state. The devices
monitored by this framework can be either of the following:
o consumers of energy (such as routers and computer systems) and
components of such devices (such as line cards, fans, and disks)
o producers of energy (like an uninterruptible power supply or
renewable energy system) and their associated components (such as
battery cells, inverters, or photovoltaic panels)
This framework further describes how to identify, classify, and
provide context for such devices. While context information is not
specific to Energy Management, some context attributes are specified
in the framework, addressing the following use cases:
o How important is a device in terms of its business impact?
o How should devices be grouped for reporting and searching?
o How should a device role be described?
Guidelines for using context for Energy Management are described.
The framework introduces the concept of a Power Interface that is
analogous to a network interface. A Power Interface is defined as an
interconnection among devices where energy can be provided, received,
or both.
The most basic example of Energy Management is a single device
reporting information about itself. In many cases, however, energy
is not measured by the device itself but is measured upstream in the
power distribution tree. For example, a Power Distribution Unit
(PDU) may measure the energy it supplies to attached devices and
<span class="grey">Parello, et al. Informational [Page 3]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-4" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
report this to an Energy Management System. Therefore, devices often
have relationships to other devices or components in the power
network. An Energy Management System (EnMS) generally requires an
understanding of the power topology (who provides power to whom), the
Metering topology (who meters whom), and the potential Aggregation
(who aggregates values of others).
The relationships build on the Power Interface concept. The
different relationships among devices and components, as specified in
this document, include power source, Metering, and Aggregation
Relationships.
The framework does not cover non-electrical equipment, nor does it
cover energy procurement and manufacturing.
<span class="h2"><a class="selflink" id="section-2" href="#section-2">2</a>. Terminology</span>
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in <a href="./rfc2119">RFC 2119</a> [<a href="./rfc2119" title=""Key words for use in RFCs to Indicate Requirement Levels"">RFC2119</a>].
In this document, these words will appear with the above
interpretation only when in ALL CAPS. Lowercase uses of these words
are not to be interpreted as carrying the significance of <a href="./rfc2119">RFC 2119</a>
key words.
In this section, some terms have a NOTE that is not part of the
definition itself but accounts for differences between terminologies
of different standards organizations or further clarifies the
definition.
The terms are listed in an order that aids in reading where terms may
build off a previous term, as opposed to an alphabetical ordering.
Some terms that are common in electrical engineering or that describe
common physical items use a lowercase notation.
Energy Management
Energy Management is a set of functions for measuring, modeling,
planning, and optimizing networks to ensure that the network and
network-attached devices use energy efficiently and appropriately
for the nature of the application and the cost constraints of the
organization.
Reference: Adapted from [<a href="#ref-TMN" title=""TMN management functions"">TMN</a>].
<span class="grey">Parello, et al. Informational [Page 4]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-5" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
NOTES:
1. "Energy Management" refers to the activities, methods,
procedures, and tools that pertain to measuring, modeling,
planning, controlling, and optimizing the use of energy in
networked systems [<a href="#ref-NMF" title=""Network Management Fundamentals"">NMF</a>].
2. Energy Management is a management domain that is congruent to
any of the FCAPS areas of management in the ISO/OSI Network
Management Model [<a href="#ref-TMN" title=""TMN management functions"">TMN</a>]. Energy Management for communication
networks and attached devices is a subset or part of an
organization's greater Energy Management Policies.
Energy Management System (EnMS)
An Energy Management System is a combination of hardware and
software used to administer a network, with the primary purpose of
Energy Management.
NOTES:
1. An Energy Management System according to [<a href="#ref-ISO50001" title=""ISO 50001:2011 Energy management systems -- Requirements with guidance for use"">ISO50001</a>] (ISO-EnMS)
is a set of systems or procedures upon which organizations can
develop and implement an energy policy, set targets and action
plans, and take into account legal requirements related to
energy use. An ISO-EnMS allows organizations to improve energy
performance and demonstrate conformity to requirements,
standards, and/or legal requirements.
2. Example ISO-EnMS: Company A defines a set of policies and
procedures indicating that there should exist multiple
computerized systems that will poll energy measurements from
their meters and pricing / source data from their local
utility. Company A specifies that their CFO (Chief Financial
Officer) should collect information and summarize it quarterly
to be sent to an accounting firm to produce carbon accounting
reporting as required by their local government.
3. For the purposes of EMAN, the definition herein is the
preferred meaning of an EnMS. The definition from [<a href="#ref-ISO50001" title=""ISO 50001:2011 Energy management systems -- Requirements with guidance for use"">ISO50001</a>]
can be referred to as an ISO Energy Management System
(ISO-EnMS).
Energy Monitoring
Energy Monitoring is a part of Energy Management that deals with
collecting or reading information from devices to aid in Energy
Management.
<span class="grey">Parello, et al. Informational [Page 5]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-6" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Energy Control
Energy Control is a part of Energy Management that deals with
directing influence over devices.
electrical equipment
This is a general term that includes materials, fittings, devices,
appliances, fixtures, apparatus, machines, etc., that are used as
a part of, or in connection with, an electric installation.
Reference: [<a href="#ref-IEEE100" title=""The Authoritative Dictionary of IEEE Standards Terms"">IEEE100</a>].
non-electrical equipment (mechanical equipment)
This is a general term that includes materials, fittings, devices,
appliances, fixtures, apparatus, machines, etc., that are used as
a part of, or in connection with, non-electrical power
installations.
Reference: Adapted from [<a href="#ref-IEEE100" title=""The Authoritative Dictionary of IEEE Standards Terms"">IEEE100</a>].
device
A device is a piece of electrical or non-electrical equipment.
Reference: Adapted from [<a href="#ref-IEEE100" title=""The Authoritative Dictionary of IEEE Standards Terms"">IEEE100</a>].
component
A component is a part of electrical or non-electrical equipment
(device).
Reference: Adapted from [<a href="#ref-TMN" title=""TMN management functions"">TMN</a>].
power inlet
A power inlet (or simply "inlet") is an interface at which a
device or component receives energy from another device or
component.
power outlet
A power outlet (or simply "outlet") is an interface at which a
device or component provides energy to another device or
component.
energy
Energy is that which does work or is capable of doing work. As
used by electric utilities, it is generally a reference to
electrical energy and is measured in kilowatt-hours (kWh).
Reference: [<a href="#ref-IEEE100" title=""The Authoritative Dictionary of IEEE Standards Terms"">IEEE100</a>].
<span class="grey">Parello, et al. Informational [Page 6]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-7" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
NOTE:
1. Energy is the capacity of a system to produce external activity
or perform work [<a href="#ref-ISO50001" title=""ISO 50001:2011 Energy management systems -- Requirements with guidance for use"">ISO50001</a>].
power
Power is the time rate at which energy is emitted, transferred, or
received; power is usually expressed in watts (joules per second).
Reference: [<a href="#ref-IEEE100" title=""The Authoritative Dictionary of IEEE Standards Terms"">IEEE100</a>].
demand
Demand is the average value of power or a related quantity over a
specified interval of time. Note: Demand is expressed in
kilowatts, kilovolt-amperes, kilovars, or other suitable units.
Reference: [<a href="#ref-IEEE100" title=""The Authoritative Dictionary of IEEE Standards Terms"">IEEE100</a>].
NOTE:
1. While IEEE100 defines demand in kilo measurements, for EMAN we
use watts with any suitable metric prefix.
provide energy
A device (or component) "provides" energy to another device if
there is an energy flow from this device to the other one.
receive energy
A device (or component) "receives" energy from another device if
there is an energy flow from the other device to this one.
meter (energy meter)
A meter is a device intended to measure electrical energy by
integrating power with respect to time.
Reference: Adapted from [<a href="#ref-IEC60050" title=""International Electrotechnical Vocabulary"">IEC60050</a>].
battery
A battery is one or more cells (consisting of an assembly of
electrodes, electrolyte, container, terminals, and (usually)
separators) that are a source and/or store of electric energy.
Reference: Adapted from [<a href="#ref-IEC60050" title=""International Electrotechnical Vocabulary"">IEC60050</a>].
Power Interface
A Power Interface is a power inlet, outlet, or both.
<span class="grey">Parello, et al. Informational [Page 7]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-8" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Nameplate Power
The Nameplate Power is the nominal power of a device as specified
by the device manufacturer.
Power Attributes
Power Attributes are measurements of the electrical current,
voltage, phase, and frequencies at a given point in an electrical
power system.
Reference: Adapted from [<a href="#ref-IEC60050" title=""International Electrotechnical Vocabulary"">IEC60050</a>].
NOTE:
1. Power Attributes are not intended to provide any bounds or
recommended range for the value. They are simply the reading
of the value associated with the attribute in question.
Power Quality
"Power Quality" refers to characteristics of the electrical
current, voltage, phase, and frequencies at a given point in an
electric power system, evaluated against a set of reference
technical parameters. These parameters might, in some cases,
relate to the compatibility between electricity supplied in an
electric power system and the loads connected to that electric
power system.
Reference: [<a href="#ref-IEC60050" title=""International Electrotechnical Vocabulary"">IEC60050</a>].
NOTE:
1. Electrical characteristics representing Power Quality
information are typically required by customer facility Energy
Management Systems. Electrical characteristics are not
intended to satisfy the detailed requirements of Power Quality
monitoring. Standards typically also give ranges of allowed
values; the information attributes are the raw measurements,
not the "yes/no" determination by the various standards.
Reference: [<a href="#ref-ASHRAE-201">ASHRAE-201</a>].
<span class="grey">Parello, et al. Informational [Page 8]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-9" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Power State
A Power State is a condition or mode of a device (or component)
that broadly characterizes its capabilities, power, and
responsiveness to input.
Reference: Adapted from [<a href="#ref-IEEE1621" title=""Standard for User Interface Elements in Power Control of Electronic Devices Employed in Office/Consumer Environments"">IEEE1621</a>].
Power State Set
A Power State Set is a collection of Power States that comprises a
named or logical control grouping.
<span class="h2"><a class="selflink" id="section-3" href="#section-3">3</a>. Target Devices</span>
With Energy Management, there exists a wide variety of devices that
may be contained in the same deployment as a communication network
but comprise a separate facility, home, or power distribution
network.
Energy Management has special challenges because a power distribution
network supplies energy to devices and components, while a separate
communications network monitors and controls the power distribution
network.
The target devices for Energy Management are all devices that can be
monitored or controlled (directly or indirectly) by an Energy
Management System (EnMS). These target devices include, for example:
o Simple electrical appliances and fixtures
o Hosts, such as a PC, a server, or a printer
o Switches, routers, base stations, and other network equipment such
as middleboxes
o Components within devices, e.g., a line card inside a switch
o Batteries functioning as a device or component that is a store of
energy
o Devices or components that charge or produce energy, such as solar
cells, charging stations, or generators
o Power over Ethernet (PoE) endpoints
o Power Distribution Units (PDUs)
o Protocol gateway devices for Building Management Systems (BMS)
<span class="grey">Parello, et al. Informational [Page 9]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-10" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
o Electrical meters
o Sensor controllers with subtended sensors
Target devices include devices that communicate via the Internet
Protocol (IP) as well as devices using other means for communication.
The latter are managed through gateways or proxies that can
communicate using IP.
<span class="h2"><a class="selflink" id="section-4" href="#section-4">4</a>. Physical Reference Model</span>
The following reference model describes physical power topologies
that exist in parallel with a communication topology. While many
more topologies can be created with a combination of devices, the
following are some basic ones that show how Energy Management
topologies differ from Network Management topologies.
NOTE: "###" is used to denote a transfer of energy.
"- >" is used to denote a transfer of information.
Basic Energy Management:
+--------------------------+
| Energy Management System |
+--------------------------+
^ ^
monitoring | | control
v v
+---------+
| device |
+---------+
Basic Power Supply:
+-----------------------------------------+
| Energy Management System |
+-----------------------------------------+
^ ^ ^ ^
monitoring | | control monitoring | | control
v v v v
+--------------+ +-----------------+
| power source |########| device |
+--------------+ +-----------------+
<span class="grey">Parello, et al. Informational [Page 10]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-11" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Single Power Supply with Multiple Devices:
+---------------------------------------+
| Energy Management System |
+---------------------------------------+
^ ^ ^ ^
monitoring | | control monitoring | | control
v v v v
+--------+ +------------------+
| power |########| device 1 |
| source | # +------------------+-+
+--------+ #######| device 2 |
# +------------------+-+
#######| device 3 |
+------------------+
Multiple Power Supplies with Single Device:
+----------------------------------------------+
| Energy Management System |
+----------------------------------------------+
^ ^ ^ ^ ^ ^
mon. | | ctrl. mon. | | ctrl. mon. | | ctrl.
v v v v v v
+----------+ +----------+ +----------+
| power |######| device |######| power |
| source 1 | | | | source 2 |
+----------+ +----------+ +----------+
<span class="h2"><a class="selflink" id="section-5" href="#section-5">5</a>. Areas Not Covered by the Framework</span>
While this framework is intended as a framework for Energy Management
in general, there are some areas that are not covered.
Non-Electrical Equipment
The primary focus of this framework is the management of
electrical equipment. Non-electrical equipment, which is not
covered in this framework, could nevertheless be modeled by
providing interfaces that comply with the framework: for example,
using the same units for power and energy. Therefore,
non-electrical equipment that does not "convert to" or
"present as" an entity equivalent to electrical equipment is not
addressed.
<span class="grey">Parello, et al. Informational [Page 11]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-12" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Energy Procurement and Manufacturing
While an EnMS may be a central point for corporate reporting, cost
computation, environmental impact analysis, and regulatory
compliance reporting, Energy Management in this framework excludes
energy procurement and the environmental impact of energy use.
As such, the framework does not include:
o Cost in currency or environmental units of manufacturing a
device
o Embedded carbon or environmental equivalences of a device
o Cost in currency or environmental impact to dismantle or
recycle a device
o Supply chain analysis of energy sources for device deployment
o Conversion of the usage or production of energy to units
expressed from the source of that energy (such as the
greenhouse gas emissions associated with the transfer of energy
from a diesel source)
<span class="h2"><a class="selflink" id="section-6" href="#section-6">6</a>. Energy Management Abstraction</span>
This section describes a conceptual model of information that can be
used for Energy Management. The classes and categories of attributes
in the model are described, with a rationale for each.
<span class="h3"><a class="selflink" id="section-6.1" href="#section-6.1">6.1</a>. Conceptual Model</span>
This section describes an information model that addresses issues
specific to Energy Management and complements existing Network
Management models.
An information model for Energy Management will need to describe a
means to monitor and control devices and components. The model will
also need to describe the relationships among, and connections
between, devices and components.
This section defines a conceptual model for devices and components
that is similar to the model used in Network Management: devices,
components, and interfaces. This section then defines the additional
attributes specific to Energy Management for those entities that are
not available in existing Network Management models.
<span class="grey">Parello, et al. Informational [Page 12]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-13" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
For modeling the devices and components, this section describes three
classes denoted by a "(Class)" suffix: a Device (Class), a Component
(Class), and a Power Interface (Class). These classes are sub-types
of an abstract Energy Object (Class).
Summary of Notation for Modeling Physical Equipment
Physical Modeling (Metadata) Model Instance
---------------------------------------------------------
equipment Energy Object (Class) Energy Object
device Device (Class) Device
component Component (Class) Component
inlet/outlet Power Interface (Class) Power Interface
This section then describes the attributes of an Energy Object
(Class) for identification, classification, context, control, power,
and energy.
Since the interconnections between devices and components for Energy
Management may have no relation to the interconnections for Network
Management, the Energy Object (Classes) contain a separate
Relationships (Class) as an attribute to model these types of
interconnections.
The next sections describe each of the classes and categories of
attributes in the information model.
Not all of the attributes are mandatory for implementations.
Specifications describing implementations of the information model in
this framework need to be explicit about which are mandatory and
which are optional to implement.
The formal definitions of the classes and attributes are specified in
<a href="#section-7">Section 7</a>.
<span class="h3"><a class="selflink" id="section-6.2" href="#section-6.2">6.2</a>. Energy Object (Class)</span>
An Energy Object (Class) represents a piece of equipment that is
part of, or attached to, a communications network that is monitored
or controlled or that aids in the management of another device for
Energy Management.
<span class="grey">Parello, et al. Informational [Page 13]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-14" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
The Energy Object (Class) is an abstract class that contains the base
attributes to represent a piece of equipment for Energy Management.
There are three types of Energy Object (Class): Device (Class),
Component (Class), and Power Interface (Class).
<span class="h4"><a class="selflink" id="section-6.2.1" href="#section-6.2.1">6.2.1</a>. Device (Class)</span>
The Device (Class) is a subclass of Energy Object (Class) that
represents a physical piece of equipment.
A Device (Class) instance represents a device that is a consumer,
producer, meter, distributor, or store of energy.
A Device (Class) instance may represent a physical device that
contains other components.
<span class="h4"><a class="selflink" id="section-6.2.2" href="#section-6.2.2">6.2.2</a>. Component (Class)</span>
The Component (Class) is a subclass of Energy Object (Class) that
represents a part of a physical piece of equipment.
<span class="h4"><a class="selflink" id="section-6.2.3" href="#section-6.2.3">6.2.3</a>. Power Interface (Class)</span>
A Power Interface (Class) represents the interconnections (inlet,
outlet) among devices or components where energy can be provided,
received, or both.
The Power Interface (Class) is a subclass of Energy Object (Class)
that represents a physical inlet or outlet.
There are some similarities between Power Interfaces and network
interfaces. A network interface can be set to different states, such
as sending or receiving data on an attached line. Similarly, a Power
Interface can be receiving or providing energy.
A Power Interface (Class) instance can represent (physically) an AC
power socket, an AC power cord attached to a device, or an 8P8C
(RJ45) PoE socket, etc.
<span class="grey">Parello, et al. Informational [Page 14]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-15" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
<span class="h3"><a class="selflink" id="section-6.3" href="#section-6.3">6.3</a>. Energy Object Attributes</span>
This section describes categories of attributes for an Energy Object
(Class).
<span class="h4"><a class="selflink" id="section-6.3.1" href="#section-6.3.1">6.3.1</a>. Identification</span>
A Universally Unique Identifier (UUID) [<a href="./rfc4122" title=""A Universally Unique IDentifier (UUID) URN Namespace"">RFC4122</a>] is used to uniquely
and persistently identify an Energy Object.
Every Energy Object has an optional unique human-readable printable
name. Possible naming conventions are textual DNS name, Media Access
Control (MAC) address of the device, interface ifName, or a text
string uniquely identifying the Energy Object. As an example, in
the case of IP phones, the Energy Object name can be the device's
DNS name.
Additionally, an alternate key is provided to allow an Energy Object
to be optionally linked with models in different systems.
<span class="h4"><a class="selflink" id="section-6.3.2" href="#section-6.3.2">6.3.2</a>. Context: General</span>
In order to aid in reporting and in differentiation between Energy
Objects, each object optionally contains information establishing its
business, site, or organizational context within a deployment.
The Energy Object (Class) contains a category attribute that broadly
describes how an instance is used in a deployment. The category
indicates whether the Energy Object is primarily functioning as a
consumer, producer, meter, distributor, or store of energy.
Given the category and context of an object, an EnMS can summarize or
analyze measurements for the site.
<span class="h4"><a class="selflink" id="section-6.3.3" href="#section-6.3.3">6.3.3</a>. Context: Importance</span>
An Energy Object can provide an importance value in the range of 1 to
100 to help rank a device's use or relative value to the site. The
importance range is from 1 (least important) to 100 (most important).
The default importance value is 1.
For example, a typical office environment has several types of
phones, which can be rated according to their business impact. A
public desk phone has a lower importance (for example, 10) than a
business-critical emergency phone (for example, 100). As another
example, a company can consider that a PC and a phone for a customer
service engineer are more important than a PC and a phone for
lobby use.
<span class="grey">Parello, et al. Informational [Page 15]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-16" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Although EnMS and administrators can establish their own ranking, the
following example is a broad recommendation for commercial
deployments [<a href="#ref-CISCO-EW" title=""Cisco EnergyWise Design Guide"">CISCO-EW</a>]:
90 to 100 Emergency response
80 to 90 Executive or business-critical
70 to 79 General or average
60 to 69 Staff or support
40 to 59 Public or guest
1 to 39 Decorative or hospitality
<span class="h4"><a class="selflink" id="section-6.3.4" href="#section-6.3.4">6.3.4</a>. Context: Keywords</span>
The Energy Object (Class) contains an attribute with context
keywords.
An Energy Object can provide a set of keywords that is a list of tags
that can be used for grouping, summary reporting (within or between
Energy Management Domains), and searching. Potential examples are
IT, lobby, HumanResources, Accounting, StoreRoom, CustomerSpace,
router, phone, floor2, or SoftwareLab.
The specifics of how this tag is represented are left to the MIB
module or other object definition documents to be based on this
framework.
There is no default value for a keyword. Multiple keywords can be
assigned to an Energy Object.
<span class="h4"><a class="selflink" id="section-6.3.5" href="#section-6.3.5">6.3.5</a>. Context: Role</span>
The Energy Object (Class) contains a role attribute. The "role
description" string indicates the primary purpose the Energy Object
serves in the deployment. This could be a string representing the
purpose the Energy Object fulfills in the deployment.
The specifics of how this tag is represented are left to the MIB
module or other object definition documents to be based on this
framework.
Administrators can define any naming scheme for the role. As
guidance, a two-word role that combines the service the Energy Object
provides, along with type, can be used [<a href="#ref-IPENERGY" title=""IP-Enabled Energy Management: A Proven Strategy for Administering Energy as a Service"">IPENERGY</a>].
Example types of devices: Router, Switch, Light, Phone, WorkStation,
Server, Display, Kiosk, HVAC.
<span class="grey">Parello, et al. Informational [Page 16]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-17" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Example Services by Line of Business:
Line of Business Service
------------------------------------------------------
Education Student, Faculty, Administration,
Athletic
Finance Trader, Teller, Fulfillment
Manufacturing Assembly, Control, Shipping
Retail Advertising, Cashier
Support Helpdesk, Management
Medical Patient, Administration, Billing
Role as a two-word string: "Faculty Desktop", "Teller Phone",
"Shipping HVAC", "Advertising Display", "Helpdesk Kiosk",
"Administration Switch".
The specifics of how this tag is represented are left to the MIB
module or other object definition documents to be based on this
framework.
<span class="h4"><a class="selflink" id="section-6.3.6" href="#section-6.3.6">6.3.6</a>. Context: Domain</span>
The Energy Object (Class) contains a string attribute to indicate
membership in an Energy Management Domain. An Energy Management
Domain can be any collection of Energy Objects in a deployment, but
it is recommended to map 1:1 with a metered or sub-metered portion of
the site.
In building management, a meter refers to the meter provided by the
utility used for billing and measuring power to an entire building or
unit within a building. A sub-meter refers to a customer- or user-
installed meter that is not used by the utility to bill but is
instead used to get measurements from portions of a building.
The specifics of how this tag is represented are left to the MIB
module or other object definition documents to be based on this
framework.
An Energy Object MUST be a member of a single Energy Management
Domain; therefore, one attribute is provided.
<span class="grey">Parello, et al. Informational [Page 17]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-18" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
<span class="h3"><a class="selflink" id="section-6.4" href="#section-6.4">6.4</a>. Measurements</span>
The Energy Object (Class) contains attributes to describe power,
energy, and demand measurements.
An analogy for understanding power versus energy measurements can be
made to speed and distance in automobiles. Just as a speedometer
indicates the rate of change of distance (speed), a power measurement
indicates the rate of transfer of energy. The odometer in an
automobile measures the cumulative distance traveled; similarly, an
energy measurement indicates the accumulated energy transferred.
Demand measurements are averages of power measurements over time.
So, using the same analogy to an automobile: measuring the average
vehicle speed over multiple intervals of time for a given distance
traveled, demand is the average power measured over multiple time
intervals for a given energy value.
Within this framework, energy will only be quantified in units of
watt-hours. Physical devices measuring energy in other units must
convert values to watt-hours or be represented by Energy Objects that
convert to watt-hours.
<span class="h4"><a class="selflink" id="section-6.4.1" href="#section-6.4.1">6.4.1</a>. Measurements: Power</span>
The Energy Object (Class) contains a Nameplate Power Attribute that
describes the nominal power as specified by the manufacturer of the
device. The EnMS can use the Nameplate Power for provisioning,
capacity planning, and (potentially) billing.
The Energy Object (Class) has attributes that describe the present
power information, along with how that measurement was obtained or
derived (e.g., actual, estimated, or static).
A power measurement is qualified with the units, magnitude, and
direction of power flow and is qualified as to the means by which the
measurement was made.
Power measurement magnitude conforms to the [<a href="#ref-IEC61850" title=""Power Utility Automation"">IEC61850</a>] definition of
unit multiplier for the SI (System International) units of measure.
Measured values are represented in SI units obtained by BaseValue *
(10 ^ Scale). For example, if current power usage of an Energy
Object is 17, it could be 17 W, 17 mW, 17 kW, or 17 MW, depending on
the value of the scaling factor. 17 W implies that BaseValue = 17
and Scale = 0, whereas 17 mW implies that BaseValue = 17 and
ScaleFactor = -3.
<span class="grey">Parello, et al. Informational [Page 18]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-19" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
An Energy Object (Class) indicates how the power measurement was
obtained with a caliber and accuracy attribute that indicates:
o Whether the measurements were made at the device itself or at a
remote source.
o Description of the method that was used to measure the power and
whether this method can distinguish actual or estimated values.
o Accuracy for actual measured values.
<span class="h4"><a class="selflink" id="section-6.4.2" href="#section-6.4.2">6.4.2</a>. Measurements: Power Attributes</span>
The Energy Object (Class) contains an optional attribute that
describes Power Attribute information reflecting the electrical
characteristics of the measurement. These Power Attributes adhere to
the [<a href="#ref-IEC61850-7-2">IEC61850-7-2</a>] standard for describing AC measurements.
<span class="h4"><a class="selflink" id="section-6.4.3" href="#section-6.4.3">6.4.3</a>. Measurements: Energy</span>
The Energy Object (Class) contains optional attributes that represent
the energy used, received, produced, and/or stored. Typically, only
devices or components that can measure actual power will have the
ability to measure energy.
<span class="h4"><a class="selflink" id="section-6.4.4" href="#section-6.4.4">6.4.4</a>. Measurements: Demand</span>
The Energy Object (Class) contains optional attributes that represent
demand information over time. Typically, only devices or components
that can report actual power are capable of measuring demand.
<span class="h3"><a class="selflink" id="section-6.5" href="#section-6.5">6.5</a>. Control</span>
The Energy Object (Class) contains a Power State Set (Class)
attribute that represents the set of Power States a device or
component supports.
A Power State describes a condition or mode of a device or component.
While Power States are typically used for control, they may be used
for monitoring only.
A device or component is expected to support at least one set of
Power States consisting of at least two states: an on state and an
off state.
There are many existing standards describing device and component
Power States. The framework supports modeling a mixed set of Power
States defined in different standards. A basic example is given by
<span class="grey">Parello, et al. Informational [Page 19]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-20" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
the three Power States defined in IEEE1621 [<a href="#ref-IEEE1621" title=""Standard for User Interface Elements in Power Control of Electronic Devices Employed in Office/Consumer Environments"">IEEE1621</a>]: on, off, and
sleep. The Distributed Management Task Force (DMTF) standards
organization [<a href="#ref-DMTF" title=""Power State Management Profile"">DMTF</a>], Advanced Configuration and Power Interface
(ACPI) specification [<a href="#ref-ACPI" title=""Advanced Configuration and Power Interface Specification"">ACPI</a>], and Printer Working Group (PWG) all
define larger numbers of Power States.
The semantics of a Power State are specified by:
a) The functionality provided by an Energy Object in this state.
b) A limitation of the power that an Energy Object uses in this
state.
c) A combination of a) and b).
The semantics of a Power State should be clearly defined. Limitation
(curtailment) of the power used by an Energy Object in a state may be
specified by:
o An absolute power value.
o A percentage value of power relative to the Energy Object's
Nameplate Power.
o An indication of power relative to another Power State. For
example, specify that power in state A is less than in state B.
o For supporting Power State management, an Energy Object provides
statistics on Power States, including the time an Energy Object
spent in a certain Power State and the number of times an Energy
Object entered a Power State.
When requesting an Energy Object to enter a Power State, an
indication of the Power State's name or number can be used.
Optionally, an absolute or percentage of Nameplate Power can be
provided to allow the Energy Object to transition to a nearest or
equivalent Power State.
When an Energy Object is set to a particular Power State, the
represented device or component may be busy. The Energy Object
should set the desired Power State and then update the actual Power
State when the device or component changes. There are then two Power
State (Class) control attributes: actual and requested.
The following sections describe well-known Power States for devices
and components that should be modeled in the information model.
<span class="grey">Parello, et al. Informational [Page 20]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-21" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
<span class="h4"><a class="selflink" id="section-6.5.1" href="#section-6.5.1">6.5.1</a>. Power State Sets</span>
There are several standards and implementations of Power State Sets.
The Energy Object (Class) supports modeling one or multiple Power
State Set implementations on the device or component concurrently.
There are currently three Power State Sets specified by IANA:
IEEE1621 (256) - [<a href="#ref-IEEE1621" title=""Standard for User Interface Elements in Power Control of Electronic Devices Employed in Office/Consumer Environments"">IEEE1621</a>]
DMTF (512) - [<a href="#ref-DMTF" title=""Power State Management Profile"">DMTF</a>]
EMAN (768) - [<a href="./rfc7326">RFC7326</a>]
The respective specific states related to each Power State Set are
specified in the following sections. The guidelines for the
modification of Power State Sets are specified in the IANA
Considerations section.
<span class="h4"><a class="selflink" id="section-6.5.2" href="#section-6.5.2">6.5.2</a>. Power State Set: IEEE1621</span>
The IEEE1621 Power State Set [<a href="#ref-IEEE1621" title=""Standard for User Interface Elements in Power Control of Electronic Devices Employed in Office/Consumer Environments"">IEEE1621</a>] consists of three rudimentary
states: on, off, or sleep.
In IEEE1621, devices are limited to the three basic Power States --
on (2), sleep (1), and off (0). Any additional Power States are
variants of one of the basic states, rather than a fourth state
[<a href="#ref-IEEE1621" title=""Standard for User Interface Elements in Power Control of Electronic Devices Employed in Office/Consumer Environments"">IEEE1621</a>].
<span class="h4"><a class="selflink" id="section-6.5.3" href="#section-6.5.3">6.5.3</a>. Power State Set: DMTF</span>
The DMTF [<a href="#ref-DMTF" title=""Power State Management Profile"">DMTF</a>] standards organization has defined a power profile
standard based on the CIM (Common Information Model), which consists
of 15 Power States.
The DMTF standard is targeted for hosts and computers. Details of
the semantics of each Power State within the DMTF Power State Set can
be obtained from the DMTF Power State Management Profile
specification [<a href="#ref-DMTF" title=""Power State Management Profile"">DMTF</a>].
<span class="grey">Parello, et al. Informational [Page 21]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-22" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
The DMTF power profile extends ACPI Power States. The following
table provides a mapping between DMTF and ACPI Power State Sets:
DMTF ACPI
------------------------------------------------
Reserved (0)
Reserved (1)
ON (2) G0/S0
Sleep-Light (3) G1/S1 G1/S2
Sleep-Deep (4) G1/S3
Power Cycle (Off-Soft) (5) G2/S5
Off-Hard (6) G3
Hibernate (Off-Soft) (7) G1/S4
Off-Soft (8) G2/S5
Power Cycle (Off-Hard) (9) G3
Master Bus Reset (10) G2/S5
Diagnostic Interrupt (11) G2/S5
Off-Soft Graceful (12) G2/S5
Off-Hard Graceful (13) G3
MasterBus Reset Graceful (14) G2/S5
Power Cycle Off-Soft Graceful (15) G2/S5
Power Cycle Off-Hard Graceful (16) G3
<span class="h4"><a class="selflink" id="section-6.5.4" href="#section-6.5.4">6.5.4</a>. Power State Set: IETF EMAN</span>
The EMAN Power States are an expansion of the basic Power States as
defined in [<a href="#ref-IEEE1621" title=""Standard for User Interface Elements in Power Control of Electronic Devices Employed in Office/Consumer Environments"">IEEE1621</a>] plus the addition of the Power States defined
in [<a href="#ref-ACPI" title=""Advanced Configuration and Power Interface Specification"">ACPI</a>] and [<a href="#ref-DMTF" title=""Power State Management Profile"">DMTF</a>]. Therefore, in addition to the non-operational
states as defined in [<a href="#ref-ACPI" title=""Advanced Configuration and Power Interface Specification"">ACPI</a>] and [<a href="#ref-DMTF" title=""Power State Management Profile"">DMTF</a>] standards, several
intermediate operational states have been defined.
Physical devices and components are expected to support the EMAN
Power State Set or to be modeled via an Energy Object the supports
these states.
An Energy Object may implement fewer or more Power States than a
particular EMAN Power State Set specifies. In that case, the Energy
Object implementation can determine its own mapping to the predefined
EMAN Power States within the EMAN Power State Set.
There are twelve EMAN Power States that expand on [<a href="#ref-IEEE1621" title=""Standard for User Interface Elements in Power Control of Electronic Devices Employed in Office/Consumer Environments"">IEEE1621</a>]. The
expanded list of Power States is derived from [<a href="#ref-CISCO-EW" title=""Cisco EnergyWise Design Guide"">CISCO-EW</a>] and is
divided into six operational states and six non-operational states.
<span class="grey">Parello, et al. Informational [Page 22]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-23" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
The lowest non-operational state is 0, and the highest is 5. Each
non-operational state corresponds to an [<a href="#ref-ACPI" title=""Advanced Configuration and Power Interface Specification"">ACPI</a>] Global and System
state between G3 (hard-off) and G1 (sleeping). Each operational
state represents a performance state and may be mapped to [<a href="#ref-ACPI" title=""Advanced Configuration and Power Interface Specification"">ACPI</a>]
states P0 (maximum performance power) through P5 (minimum performance
and minimum power).
In each of the non-operational states (from mechoff(0) to ready(5)),
the Power State preceding it is expected to have a lower Power value
and a longer delay in returning to an operational state:
mechoff(0): An off state where no Energy Object features are
available. The Energy Object is unavailable. No energy is
being consumed, and the power connector can be removed.
softoff(1): Similar to mechoff(0), but some components remain
powered or receive trace power so that the Energy Object can be
awakened from its off state. In softoff(1), no context is
saved, and the device typically requires a complete boot when
awakened.
hibernate(2): No Energy Object features are available. The Energy
Object may be awakened without requiring a complete boot, but
the time for availability is longer than sleep(3). An example
for state hibernate(2) is a save-to-disk state where DRAM
context is not maintained. Typically, energy consumption is
zero or close to zero.
sleep(3): No Energy Object features are available, except for
out-of-band management, such as wake-up mechanisms. The time
for availability is longer than standby(4). An example for
state sleep(3) is a save-to-RAM state, where DRAM context is
maintained. Typically, energy consumption is close to zero.
standby(4): No Energy Object features are available, except for
out-of-band management, such as wake-up mechanisms. This mode
is analogous to cold-standby. The time for availability is
longer than ready(5). For example, processor context may not
be maintained. Typically, energy consumption is close to zero.
ready(5): No Energy Object features are available, except for
out-of-band management, such as wake-up mechanisms. This mode
is analogous to hot-standby. The Energy Object can be quickly
transitioned into an operational state. For example,
processors are not executing, but processor context is
maintained.
<span class="grey">Parello, et al. Informational [Page 23]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-24" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
lowMinus(6): Indicates that some Energy Object features may not be
available and the Energy Object has taken measures or selected
options to use less energy than low(7).
low(7): Indicates that some Energy Object features may not be
available and the Energy Object has taken measures or selected
options to use less energy than mediumMinus(8).
mediumMinus(8): Indicates that all Energy Object features are
available but the Energy Object has taken measures or selected
options to use less energy than medium(9).
medium(9): Indicates that all Energy Object features are available
but the Energy Object has taken measures or selected options to
use less energy than highMinus(10).
highMinus(10): Indicates that all Energy Object features are
available and the Energy Object has taken measures or selected
options to use less energy than high(11).
high(11): Indicates that all Energy Object features are available
and the Energy Object may use the maximum energy as indicated
by the Nameplate Power.
<span class="h4"><a class="selflink" id="section-6.5.5" href="#section-6.5.5">6.5.5</a>. Power State Sets Comparison</span>
A comparison of Power States from different Power State Sets can be
seen in the following tables:
Non-operational states:
IEEE1621 DMTF ACPI EMAN
--------------------------------------------------
off Off-Hard G3/S5 mechoff(0)
off Off-Soft G2/S5 softoff(1)
off Hibernate G1/S4 hibernate(2)
sleep Sleep-Deep G1/S3 sleep(3)
sleep Sleep-Light G1/S2 standby(4)
sleep Sleep-Light G1/S1 ready(5)
<span class="grey">Parello, et al. Informational [Page 24]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-25" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Operational states:
IEEE1621 DMTF ACPI EMAN
----------------------------------------------------
on on G0/S0/P5 lowMinus(6)
on on G0/S0/P4 low(7)
on on G0/S0/P3 mediumMinus(8)
on on G0/S0/P2 medium(9)
on on G0/S0/P1 highMinus(10)
on on G0/S0/P0 high(11)
<span class="h3"><a class="selflink" id="section-6.6" href="#section-6.6">6.6</a>. Relationships</span>
The Energy Object (Class) contains a set of Relationship (Class)
attributes to model the relationships between devices and components.
Two Energy Objects can establish an Energy Object Relationship to
model the deployment topology with respect to Energy Management.
Relationships are modeled with a Relationship (Class) that contains
the UUID of the other participant in the relationship and a name that
describes the type of relationship [<a href="#ref-CHEN" title=""The Entity-Relationship Model: Toward a Unified View of Data"">CHEN</a>]. The types of
relationships are Power Source, Metering, and Aggregations.
o A Power Source Relationship is a relationship where one Energy
Object provides power to one or more Energy Objects. The Power
Source Relationship gives a view of the physical wiring topology
-- for example, a data center server receiving power from two
specific Power Interfaces from two different PDUs.
Note: A Power Source Relationship may or may not change as the
direction of power changes between two Energy Objects. The
relationship may remain to indicate that the change of power
direction was unintended or an error condition.
o A Metering Relationship is a relationship where one Energy Object
measures power, energy, demand, or Power Attributes of one or more
other Energy Objects. The Metering Relationship gives the view of
the Metering topology. Physical meters can be placed anywhere in
a power distribution tree. For example, utility meters monitor
and report accumulated power consumption of the entire building.
Logically, the Metering topology overlaps with the wiring
topology, as meters are connected to the wiring topology. A
typical example is meters that clamp onto the existing wiring.
<span class="grey">Parello, et al. Informational [Page 25]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-26" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
o An Aggregation Relationship is a relationship where one Energy
Object aggregates Energy Management information of one or more
other Energy Objects. The Aggregation Relationship gives a model
of devices that may aggregate (sum, average, etc.) values for
other devices. The Aggregation Relationship is slightly different
compared to the other relationships, as this refers more to a
management function.
In some situations, it is not possible to discover the Energy Object
Relationships, and an EnMS or administrator must set them. Given
that relationships can be assigned manually, the following sections
describe guidelines for use.
<span class="h4"><a class="selflink" id="section-6.6.1" href="#section-6.6.1">6.6.1</a>. Relationship Conventions and Guidelines</span>
This Energy Management framework does not impose many "MUST" rules
related to Energy Object Relationships. There are always corner
cases that can be excluded by making stricter specifications for
relationships. However, the framework proposes a series of
guidelines, indicated with "SHOULD" and "MAY".
<span class="h4"><a class="selflink" id="section-6.6.2" href="#section-6.6.2">6.6.2</a>. Guidelines: Power Source</span>
Power Source Relationships are intended to identify the connections
between Power Interfaces. This is analogous to a Layer 2 connection
in networking devices (a "one-hop connection").
The preferred modeling would be for Power Interfaces to participate
in Power Source Relationships. In some cases, Energy Objects may not
have the capability to model Power Interfaces. Therefore, a Power
Source Relationship can be established between two Energy Objects or
two non-connected Power Interfaces.
Strictly speaking, while components and Power Interfaces on the same
Device do provide or receive energy from each other, the Power Source
Relationship is intended to show energy transfer between Devices.
Therefore, the relationship is implied when on the same Device.
An Energy Object SHOULD NOT establish a Power Source Relationship
with a component.
o A Power Source Relationship SHOULD be established with the next
known Power Interface in the wiring topology.
<span class="grey">Parello, et al. Informational [Page 26]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-27" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
o The next known Power Interface in the wiring topology would be the
next device implementing the framework. In some cases, the domain
of devices under management may include some devices that do not
implement the framework. In these cases, the Power Source
Relationship can be established with the next device in the
topology that implements the framework and logically shows the
Power Source of the device.
o Transitive Power Source Relationships SHOULD NOT be established.
For example, if Energy Object A has a Power Source Relationship
"Poweredby" with Energy Object B, and if Energy Object B has a
Power Source Relationship "Poweredby" with Energy Object C, then
Energy Object A SHOULD NOT have a Power Source Relationship
"Poweredby" with Energy Object C.
<span class="h4"><a class="selflink" id="section-6.6.3" href="#section-6.6.3">6.6.3</a>. Guidelines: Metering Relationship</span>
Metering Relationships are intended to show when one device acting as
a meter is measuring the power or energy at a point in a power
distribution system. Since one point of a power distribution system
may cover many devices within a wiring topology, this relationship
type can be seen as a set.
Some devices may include hardware that can measure power for
components, outlets, or the entire device. For example, some PDUs
may have the ability to measure power for each outlet and are
commonly referred to as metered-by-outlet. Others may be able to
control power at each power outlet but can only measure power at the
power inlet -- commonly referred to as metered-by-device.
While the Metering Relationship could be used to represent a device
as metered-by-outlet or metered-by-device, the Metering Relationship
SHOULD be used to model the relationship between a meter and all
devices covered by the meter downstream in the power distribution
system.
In general:
o A Metering Relationship MAY be established with any other Energy
Object, component, or Power Interface.
o Transitive Metering Relationships MAY be used.
o When there is a series of meters for one Energy Object, the Energy
Object MAY establish a Metering Relationship with one or more of
the meters.
<span class="grey">Parello, et al. Informational [Page 27]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-28" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
<span class="h4"><a class="selflink" id="section-6.6.4" href="#section-6.6.4">6.6.4</a>. Guidelines: Aggregation</span>
Aggregation Relationships are intended to identify when one device is
used to accumulate values from other devices. Typically, this is for
energy or power values among devices and not for components or Power
Interfaces on the same device.
The intent of Aggregation Relationships is to indicate when one
device is providing aggregate values for a set of other devices when
it is not obvious from the power source or simple containment within
a device.
Establishing Aggregation Relationships within the same device would
make modeling more complex, and the aggregated values can be implied
from the use of power inlets, outlet, and Energy Object values on the
same device.
Since an EnMS is naturally a point of Aggregation, it is not
necessary to model Aggregation for Energy Management Systems.
The Aggregation Relationship is intended for power and energy. It
MAY be used for Aggregation of other values from the information
model, but the rules and logical ability to aggregate each attribute
are out of scope for this document.
In general:
o A Device SHOULD NOT establish an Aggregation Relationship with
components contained on the same device.
o A Device SHOULD NOT establish an Aggregation Relationship with the
Power Interfaces contained on the same device.
o A Device SHOULD NOT establish an Aggregation Relationship with an
EnMS.
o Aggregators SHOULD log or provide notification in the case of
errors or missing values while performing Aggregation.
<span class="grey">Parello, et al. Informational [Page 28]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-29" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
<span class="h4"><a class="selflink" id="section-6.6.5" href="#section-6.6.5">6.6.5</a>. Energy Object Relationship Extensions</span>
This framework for Energy Management is based on three relationship
types: Aggregation, Metering, and Power Source.
This framework is defined with possible future extension of new
Energy Object Relationships in mind.
For example:
o Some Devices that may not be IP connected could be modeled with a
proxy relationship to an Energy Object within the domain. This
type of proxy relationship is left for further development.
o A Power Distribution Unit (PDU) that allows devices and components
like outlets to be "ganged" together as a logical entity for
simplified management purposes could be modeled with an extension
called a "gang relationship", whose semantics would specify the
Energy Objects' grouping.
<span class="h2"><a class="selflink" id="section-7" href="#section-7">7</a>. Energy Management Information Model</span>
This section presents an information model expression of the concepts
in this framework as a reference for implementers. The information
model is implemented as MIB modules in the different related IETF
EMAN documents. However, other programming structures with different
data models could be used as well.
Data modeling specifications of this information model may, where
needed, specify which attributes are required or optional.
Syntax
Unified Modeling
Language (UML)
Construct
[<a href="#ref-ISO-IEC-19501-2005">ISO-IEC-19501-2005</a>] Equivalent Notation
-------------------- ----------------------------------
Notes // Notes
Class
(Generalization) CLASS name {member..}
Subclass
(Specialization) CLASS subclass
EXTENDS superclass {member..}
Class Member
(Attribute) attribute : type
<span class="grey">Parello, et al. Informational [Page 29]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-30" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Model
CLASS EnergyObject {
// identification / classification
index : int
name : string
identifier : uuid
alternatekey : string
// context
domainName : string
role : string
keywords [0..n] : string
importance : int
// relationship
relationships [0..n] : Relationship
// measurements
nameplate : Nameplate
power : PowerMeasurement
energy : EnergyMeasurement
demand : DemandMeasurement
// control
powerControl [0..n] : PowerStateSet
}
CLASS PowerInterface EXTENDS EnergyObject {
eoIfType : enum { inlet, outlet, both }
}
CLASS Device EXTENDS EnergyObject {
eocategory : enum { producer, consumer, meter,
distributor, store }
powerInterfaces [0..n] : PowerInterface
components [0..n] : Component
}
CLASS Component EXTENDS EnergyObject {
eocategory : enum { producer, consumer, meter,
distributor, store }
powerInterfaces [0..n] : PowerInterface
components [0..n] : Component
}
<span class="grey">Parello, et al. Informational [Page 30]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-31" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
CLASS Nameplate {
nominalPower : PowerMeasurement
details : URI
}
CLASS Relationship {
relationshipType : enum { meters, meteredby, powers,
poweredby, aggregates, aggregatedby }
relationshipObject : uuid
}
CLASS Measurement {
multiplier : enum { -24..24 }
caliber : enum { actual, estimated, static }
accuracy : enum { 0..10000 } // hundreds of percent
}
CLASS PowerMeasurement EXTENDS Measurement {
value : long
units : "W"
powerAttribute : PowerAttribute
}
CLASS EnergyMeasurement EXTENDS Measurement {
startTime : time
units : "kWh"
provided : long
used : long
produced : long
stored : long
}
CLASS TimedMeasurement EXTENDS Measurement {
startTime : timestamp
value : Measurement
maximum : Measurement
}
CLASS TimeInterval {
value : long
units : enum { seconds, milliseconds,... }
}
<span class="grey">Parello, et al. Informational [Page 31]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-32" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
CLASS DemandMeasurement EXTENDS Measurement {
intervalLength : TimeInterval
intervals : long
intervalMode : enum { periodic, sliding, total }
intervalWindow : TimeInterval
sampleRate : TimeInterval
status : enum { active, inactive }
measurements [0..n] : TimedMeasurements
}
CLASS PowerStateSet {
powerSetIdentifier : int
name : string
powerStates [0..n] : PowerState
operState : int
adminState : int
reason : string
configuredTime : timestamp
}
CLASS PowerState {
powerStateIdentifier : int
name : string
cardinality : int
maximumPower : PowerMeasurement
totalTimeInState : time
entryCount : long
}
CLASS PowerAttribute {
acQuality : ACQuality
}
CLASS ACQuality {
acConfiguration : enum { SNGL, DEL, WYE }
avgVoltage : long
avgCurrent : long
thdCurrent : long
frequency : long
unitMultiplier : int
accuracy : int
totalActivePower : long
totalReactivePower : long
totalApparentPower : long
totalPowerFactor : long
}
<span class="grey">Parello, et al. Informational [Page 32]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-33" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
CLASS DelPhase EXTENDS ACQuality {
phaseToNextPhaseVoltage : long
thdVoltage : long
}
CLASS WYEPhase EXTENDS ACQuality {
phaseToNeutralVoltage : long
thdCurrent : long
thdVoltage : long
avgCurrent : long
}
<span class="h2"><a class="selflink" id="section-8" href="#section-8">8</a>. Modeling Relationships between Devices</span>
In this section, we give examples of how to use the EMAN information
model to model physical topologies. Where applicable, we show how
the framework can be applied when devices can be modeled with Power
Interfaces. We also show how the framework can be applied when
devices cannot be modeled with Power Interfaces but only monitored or
controlled as a whole. For instance, a PDU may only be able to
measure power and energy for the entire unit without the ability to
distinguish among the inlets or outlets.
<span class="h3"><a class="selflink" id="section-8.1" href="#section-8.1">8.1</a>. Power Source Relationship</span>
The Power Source Relationship is used to model the interconnections
between devices, components, and/or Power Interfaces to indicate the
source of energy for a device.
In the following examples, we show variations on modeling the
reference topologies using relationships.
Given for all cases:
Device W: A computer with one power supply. Power Interface 1 is an
inlet for Device W.
Device X: A computer with two power supplies. Power Interface 1 and
Power Interface 2 are both inlets for Device X.
Device Y: A PDU with multiple Power Interfaces numbered 0..10. Power
Interface 0 is an inlet, and Power Interfaces 1..10 are outlets.
Device Z: A PDU with multiple Power Interfaces numbered 0..10. Power
Interface 0 is an inlet, and Power Interfaces 1..10 are outlets.
<span class="grey">Parello, et al. Informational [Page 33]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-34" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Case 1: Simple Device with one Source
Physical Topology:
o Device W inlet 1 is plugged into Device Y outlet 8.
With Power Interfaces:
o Device W has an Energy Object representing the computer
itself as well as one Power Interface defined as an inlet.
o Device Y would have an Energy Object representing the PDU
itself (the Device), with Power Interface 0 defined as an
inlet and Power Interfaces 1..10 defined as outlets.
The interfaces of the devices would have a Power Source
Relationship such that:
Device W inlet 1 is powered by Device Y outlet 8.
+-------+------+ poweredBy +------+----------+
| PDU Y | PI 8 |-----------------| PI 1 | Device W |
+-------+------+ powers +------+----------+
Without Power Interfaces:
o Device W has an Energy Object representing the computer.
o Device Y would have an Energy Object representing the PDU.
The devices would have a Power Source Relationship such that:
Device W is powered by Device Y.
+----------+ poweredBy +------------+
| PDU Y |-----------------| Device W |
+----------+ powers +------------+
<span class="grey">Parello, et al. Informational [Page 34]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-35" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Case 2: Multiple Inlets
Physical Topology:
o Device X inlet 1 is plugged into Device Y outlet 8.
o Device X inlet 2 is plugged into Device Y outlet 9.
With Power Interfaces:
o Device X has an Energy Object representing the computer
itself. It contains two Power Interfaces defined as inlets.
o Device Y would have an Energy Object representing the PDU
itself (the Device), with Power Interface 0 defined as an
inlet and Power Interfaces 1..10 defined as outlets.
The interfaces of the devices would have a Power Source
Relationship such that:
Device X inlet 1 is powered by Device Y outlet 8.
Device X inlet 2 is powered by Device Y outlet 9.
+-------+------+ poweredBy+------+----------+
| | PI 8 |-----------------| PI 1 | |
| | |powers | | |
| PDU Y +------+ poweredBy+------+ Device X |
| | PI 9 |-----------------| PI 2 | |
| | |powers | | |
+-------+------+ +------+----------+
Without Power Interfaces:
o Device X has an Energy Object representing the computer.
Device Y has an Energy Object representing the PDU.
The devices would have a Power Source Relationship such that:
Device X is powered by Device Y.
+----------+ poweredBy +------------+
| PDU Y |-----------------| Device X |
+----------+ powers +------------+
<span class="grey">Parello, et al. Informational [Page 35]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-36" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Case 3: Multiple Sources
Physical Topology:
o Device X inlet 1 is plugged into Device Y outlet 8.
o Device X inlet 2 is plugged into Device Z outlet 9.
With Power Interfaces:
o Device X has an Energy Object representing the computer
itself. It contains two Power Interfaces defined as inlets.
o Device Y would have an Energy Object representing the PDU
itself (the Device), with Power Interface 0 defined as an
inlet and Power Interfaces 1..10 defined as outlets.
o Device Z would have an Energy Object representing the PDU
itself (the Device), with Power Interface 0 defined as an
inlet and Power Interfaces 1..10 defined as outlets.
The interfaces of the devices would have a Power Source
Relationship such that:
Device X inlet 1 is powered by Device Y outlet 8.
Device X inlet 2 is powered by Device Z outlet 9.
+-------+------+ poweredBy+------+----------+
| PDU Y | PI 8 |-----------------| PI 1 | |
| | |powers | | |
+-------+------+ +------+ |
| Device X |
+-------+------+ poweredBy+------+ |
| PDU Z | PI 9 |-----------------| PI 2 | |
| | |powers | | |
+-------+------+ +------+----------+
Without Power Interfaces:
o Device X has an Energy Object representing the computer.
Devices Y and Z would both have respective Energy Objects
representing each entire PDU.
<span class="grey">Parello, et al. Informational [Page 36]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-37" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
The devices would have a Power Source Relationship such that:
Device X is powered by Device Y and powered by Device Z.
+----------+ poweredBy +------------+
| PDU Y |---------------------| Device X |
+----------+ powers +------------+
+----------+ poweredBy +------------+
| PDU Z |---------------------| Device X |
+----------+ powers +------------+
<span class="h3"><a class="selflink" id="section-8.2" href="#section-8.2">8.2</a>. Metering Relationship</span>
A meter in a power distribution system can logically measure the
power or energy for all devices downstream from the meter in the
power distribution system. As such, a Metering Relationship can be
seen as a relationship between a meter and all of the devices
downstream from the meter.
We define in this case a Metering Relationship between a meter and
devices downstream from the meter.
+-----+---+ meteredBy +--------+ poweredBy +-------+
|Meter| PI|--------------| switch |-------------| phone |
+-----+---+ meters +--------+ powers +-------+
| |
| meteredBy |
+-------------------------------------------+
meters
In cases where the Power Source topology cannot be discovered or
derived from the information available in the Energy Management
Domain, the Metering topology can be used to relate the upstream
meter to the downstream devices in the absence of specific Power
Source Relationships.
<span class="grey">Parello, et al. Informational [Page 37]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-38" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
A Metering Relationship can occur between devices that are not
directly connected, as shown in the following figure:
+---------------+
| Device 1 |
+---------------+
| PI |
+---------------+
|
+---------------+
| Meter |
+---------------+
.
.
.
meters meters meters
+----------+ +----------+ +-----------+
| Device A | | Device B | | Device C |
+----------+ +----------+ +-----------+
An analogy to communications networks would be modeling connections
between servers (meters) and clients (devices) when the complete
Layer 2 topology between the servers and clients is not known.
<span class="h3"><a class="selflink" id="section-8.3" href="#section-8.3">8.3</a>. Aggregation Relationship</span>
Some devices can act as Aggregation points for other devices. For
example, a PDU controller device may contain the summation of power
and energy readings for many PDU devices. The PDU controller will
have aggregate values for power and energy for a group of PDU
devices.
This Aggregation is independent of the physical power or
communication topology.
The functions that the Aggregation point may perform include the
calculation of values such as average, count, maximum, median,
minimum, or the listing (collection) of the Aggregation values, etc.
Based on IETF experience gained on Aggregations [<a href="./rfc7015" title=""Flow Aggregation for the IP Flow Information Export (IPFIX) Protocol"">RFC7015</a>], the
Aggregation function in the EMAN framework is limited to the
summation.
When Aggregation occurs across a set of entities, values to be
aggregated may be missing for some entities. The EMAN framework does
not specify how these should be treated, as different implementations
may have good reason to take different approaches. One common
treatment is to define the Aggregation as missing if any of the
<span class="grey">Parello, et al. Informational [Page 38]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-39" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
constituent elements are missing (useful to be most precise).
Another is to treat the missing value as zero (useful to have
continuous data streams).
The specifications of Aggregation functions are out of the scope of
the EMAN framework but must be clearly specified by the equipment
vendor.
<span class="h2"><a class="selflink" id="section-9" href="#section-9">9</a>. Relationship to Other Standards</span>
This Energy Management framework uses, as much as possible, existing
standards, especially with respect to information modeling and data
modeling [<a href="./rfc3444" title=""On the Difference between Information Models and Data Models"">RFC3444</a>].
The data model for power- and energy-related objects is based on
[<a href="#ref-IEC61850" title=""Power Utility Automation"">IEC61850</a>].
Specific examples include:
o The scaling factor, which represents Energy Object usage
magnitude, conforms to the [<a href="#ref-IEC61850" title=""Power Utility Automation"">IEC61850</a>] definition of unit
multiplier for the SI (System International) units of measure.
o The electrical characteristics are based on the ANSI and IEC
Standards, which require that we use an accuracy class for power
measurement. ANSI and IEC define the following accuracy classes
for power measurement:
- IEC 62053-22 and 60044-1 classes 0.1, 0.2, 0.5, 1, and 3.
- ANSI C12.20 classes 0.2 and 0.5.
o The electrical characteristics and quality adhere closely to the
[<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] standard for describing AC measurements.
o The Power State definitions are based on the DMTF Power State
Profile and ACPI models, with operational state extensions.
<span class="h2"><a class="selflink" id="section-10" href="#section-10">10</a>. Security Considerations</span>
Regarding the data attributes specified here, some or all may be
considered sensitive or vulnerable in some network environments.
Reading or writing these attributes without proper protection such as
encryption or access authorization will have negative effects on
network capabilities. Event logs for audit purposes on configuration
and other changes should be generated according to current
<span class="grey">Parello, et al. Informational [Page 39]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-40" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
authorization, audit, and accounting principles to facilitate
investigations (compromise or benign misconfigurations) or any
reporting requirements.
The information and control capabilities specified in this framework
could be exploited, to the detriment of a site or deployment.
Implementers of the framework SHOULD examine and mitigate security
threats with respect to these new capabilities.
"User-based Security Model (USM) for version 3 of the Simple Network
Management Protocol (SNMPv3)" [<a href="./rfc3414" title=""User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)"">RFC3414</a>] presents a good description
of threats and mitigations for SNMPv3 that can be used as a guide for
implementations of this framework using other protocols.
<span class="h3"><a class="selflink" id="section-10.1" href="#section-10.1">10.1</a>. Security Considerations for SNMP</span>
Readable objects in MIB modules (i.e., objects with a MAX-ACCESS
other than not-accessible) may be considered sensitive or vulnerable
in some network environments. It is important to control GET and/or
NOTIFY access to these objects and possibly to encrypt the values of
these objects when sending them over the network via SNMP.
The support for SET operations in a non-secure environment without
proper protection can have a negative effect on network operations.
For example:
o Unauthorized changes to the Energy Management Domain or business
context of a device will result in misreporting or interruption of
power.
o Unauthorized changes to a Power State will disrupt the power
settings of the different devices and therefore the state of
functionality of the respective devices.
o Unauthorized changes to the demand history will disrupt proper
accounting of energy usage.
With respect to data transport, SNMP versions prior to SNMPv3 did not
include adequate security. Even if the network itself is secure (for
example, by using IPsec), there is still no secure control over who
on the secure network is allowed to access and GET/SET
(read/change/create/delete) the objects in these MIB modules.
It is recommended that implementers consider the security features as
provided by the SNMPv3 framework (see [<a href="./rfc3411" title=""An Architecture for Describing Simple Network Management Protocol (SNMP) Management Frameworks"">RFC3411</a>]), including full
support for the SNMPv3 cryptographic mechanisms (for authentication
and confidentiality).
<span class="grey">Parello, et al. Informational [Page 40]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-41" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Further, deployment of SNMP versions prior to SNMPv3 is not
recommended. Instead, it is recommended to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of these MIB modules is properly configured to give access
to the objects only to those principals (users) that have legitimate
rights to GET or SET (change/create/delete) them.
<span class="h2"><a class="selflink" id="section-11" href="#section-11">11</a>. IANA Considerations</span>
<span class="h3"><a class="selflink" id="section-11.1" href="#section-11.1">11.1</a>. IANA Registration of New Power State Sets</span>
This document specifies an initial set of Power State Sets. The list
of these Power State Sets with their numeric identifiers is given in
<a href="#section-6">Section 6</a>. IANA maintains the lists of Power State Sets.
New assignments for a Power State Set are administered by IANA
through Expert Review [<a href="./rfc5226" title="">RFC5226</a>], i.e., review by one of a group of
experts designated by an IETF Area Director. The group of experts
must check the requested state for completeness and accuracy of the
description. A pure vendor-specific implementation of a Power State
Set shall not be adopted, since it would lead to proliferation of
Power State Sets.
Power States in a Power State Set are limited to 255 distinct values.
A new Power State Set must be assigned the next available numeric
identifier that is a multiple of 256.
<span class="h4"><a class="selflink" id="section-11.1.1" href="#section-11.1.1">11.1.1</a>. IANA Registration of the IEEE1621 Power State Set</span>
This document specifies a set of values for the IEEE1621 Power State
Set [<a href="#ref-IEEE1621" title=""Standard for User Interface Elements in Power Control of Electronic Devices Employed in Office/Consumer Environments"">IEEE1621</a>]. The list of these values with their identifiers is
given in <a href="#section-6.5.2">Section 6.5.2</a>. IANA created a new registry for IEEE1621
Power State Set identifiers and filled it with the initial list of
identifiers.
New assignments (or, potentially, deprecation) for the IEEE1621 Power
State Set are administered by IANA through Expert Review [<a href="./rfc5226" title="">RFC5226</a>].
<span class="h4"><a class="selflink" id="section-11.1.2" href="#section-11.1.2">11.1.2</a>. IANA Registration of the DMTF Power State Set</span>
This document specifies a set of values for the DMTF Power State Set
[<a href="#ref-DMTF" title=""Power State Management Profile"">DMTF</a>]. The list of these values with their identifiers is given in
<a href="#section-6.5.3">Section 6.5.3</a>. IANA has created a new registry for DMTF Power State
Set identifiers and filled it with the initial list of identifiers.
New assignments (or, potentially, deprecation) for the DMTF Power
State Set are administered by IANA through Expert Review [<a href="./rfc5226" title="">RFC5226</a>].
<span class="grey">Parello, et al. Informational [Page 41]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-42" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
The group of experts must check for conformance with the DMTF
standard [<a href="#ref-DMTF" title=""Power State Management Profile"">DMTF</a>] in addition to checking for completeness and accuracy
of the description.
<span class="h4"><a class="selflink" id="section-11.1.3" href="#section-11.1.3">11.1.3</a>. IANA Registration of the EMAN Power State Set</span>
This document specifies a set of values for the EMAN Power State Set.
The list of these values with their identifiers is given in
<a href="#section-6.5.4">Section 6.5.4</a>. IANA has created a new registry for EMAN Power State
Set identifiers and filled it with the initial list of identifiers.
New assignments (or, potentially, deprecation) for the EMAN Power
State Set are administered by IANA through Expert Review [<a href="./rfc5226" title="">RFC5226</a>].
<span class="h3"><a class="selflink" id="section-11.2" href="#section-11.2">11.2</a>. Updating the Registration of Existing Power State Sets</span>
With the evolution of standards, over time, it may be important to
deprecate some of the existing Power State Sets, or to add or
deprecate some Power States within a Power State Set.
The registrant shall post an Internet-Draft with the clear
specification on deprecation of Power State Sets or Power States
registered with IANA. The deprecation or addition shall be
administered by IANA through Expert Review [<a href="./rfc5226" title="">RFC5226</a>], i.e., review by
one of a group of experts designated by an IETF Area Director. The
process should also allow for a mechanism for cases where others have
significant objections to claims regarding the deprecation of a
registration.
<span class="grey">Parello, et al. Informational [Page 42]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-43" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
<span class="h2"><a class="selflink" id="section-12" href="#section-12">12</a>. References</span>
<span class="h3"><a class="selflink" id="section-12.1" href="#section-12.1">12.1</a>. Normative References</span>
[<a id="ref-RFC2119">RFC2119</a>] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", <a href="https://www.rfc-editor.org/bcp/bcp14">BCP 14</a>, <a href="./rfc2119">RFC 2119</a>, March 1997.
[<a id="ref-RFC3411">RFC3411</a>] Harrington, D., Presuhn, R., and B. Wijnen, "An
Architecture for Describing Simple Network Management
Protocol (SNMP) Management Frameworks", STD 62, <a href="./rfc3411">RFC 3411</a>,
December 2002.
[<a id="ref-RFC3414">RFC3414</a>] Blumenthal, U. and B. Wijnen, "User-based Security Model
(USM) for version 3 of the Simple Network Management
Protocol (SNMPv3)", STD 62, <a href="./rfc3414">RFC 3414</a>, December 2002.
[<a id="ref-RFC3444">RFC3444</a>] Pras, A. and J. Schoenwaelder, "On the Difference between
Information Models and Data Models", <a href="./rfc3444">RFC 3444</a>,
January 2003.
[<a id="ref-RFC4122">RFC4122</a>] Leach, P., Mealling, M., and R. Salz, "A Universally
Unique IDentifier (UUID) URN Namespace", <a href="./rfc4122">RFC 4122</a>,
July 2005.
[<a id="ref-RFC5226">RFC5226</a>] Narten, T. and H. Alvestrand, "Guidelines for Writing an
IANA Considerations Section in RFCs", <a href="https://www.rfc-editor.org/bcp/bcp26">BCP 26</a>, <a href="./rfc5226">RFC 5226</a>,
May 2008.
[<a id="ref-RFC6933">RFC6933</a>] Bierman, A., Romascanu, D., Quittek, J., and M.
Chandramouli, "Entity MIB (Version 4)", <a href="./rfc6933">RFC 6933</a>,
May 2013.
[<a id="ref-RFC6988">RFC6988</a>] Quittek, J., Ed., Chandramouli, M., Winter, R., Dietz, T.,
and B. Claise, "Requirements for Energy Management",
<a href="./rfc6988">RFC 6988</a>, September 2013.
[<a id="ref-ISO-IEC-19501-2005">ISO-IEC-19501-2005</a>]
ISO/IEC 19501:2005, Information technology, Open
Distributed Processing -- Unified Modeling Language (UML)
Version 1.4.2, January 2005.
<span class="grey">Parello, et al. Informational [Page 43]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-44" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
<span class="h3"><a class="selflink" id="section-12.2" href="#section-12.2">12.2</a>. Informative References</span>
[<a id="ref-RFC3986">RFC3986</a>] Berners-Lee, T., Fielding, R., and L. Masinter, "Uniform
Resource Identifier (URI): Generic Syntax", STD 66,
<a href="./rfc3986">RFC 3986</a>, January 2005.
[<a id="ref-RFC7015">RFC7015</a>] Trammell, B., Wagner, A., and B. Claise, "Flow Aggregation
for the IP Flow Information Export (IPFIX) Protocol",
<a href="./rfc7015">RFC 7015</a>, September 2013.
[<a id="ref-ACPI">ACPI</a>] "Advanced Configuration and Power Interface
Specification", October 2006,
<<a href="http://www.acpi.info/spec30b.htm">http://www.acpi.info/spec30b.htm</a>>.
[<a id="ref-IEEE1621">IEEE1621</a>] "Standard for User Interface Elements in Power Control of
Electronic Devices Employed in Office/Consumer
Environments", IEEE 1621, December 2004.
[<a id="ref-NMF">NMF</a>] Clemm, A., "Network Management Fundamentals",
ISBN-10: 1-58720-137-2, Cisco Press, November 2006.
[<a id="ref-TMN">TMN</a>] International Telecommunication Union, "TMN management
functions", ITU-T Recommendation M.3400, February 2000.
[<a id="ref-IEEE100">IEEE100</a>] "The Authoritative Dictionary of IEEE Standards Terms",
<<a href="http://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=4116785">http://ieeexplore.ieee.org/xpl/</a>
<a href="http://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=4116785">mostRecentIssue.jsp?punumber=4116785</a>>.
[<a id="ref-ISO50001">ISO50001</a>] "ISO 50001:2011 Energy management systems -- Requirements
with guidance for use", June 2011, <<a href="http://www.iso.org/">http://www.iso.org/</a>>.
[<a id="ref-IEC60050">IEC60050</a>] "International Electrotechnical Vocabulary",
<<a href="http://www.electropedia.org/iev/iev.nsf/welcome?openform">http://www.electropedia.org/iev/iev.nsf/</a>
<a href="http://www.electropedia.org/iev/iev.nsf/welcome?openform">welcome?openform</a>>.
[<a id="ref-IEC61850">IEC61850</a>] "Power Utility Automation",
<<a href="http://www.iec.ch/smartgrid/standards/">http://www.iec.ch/smartgrid/standards/</a>>.
[<a id="ref-IEC61850-7-2">IEC61850-7-2</a>]
"Abstract communication service interface (ACSI)",
<<a href="http://www.iec.ch/smartgrid/standards/">http://www.iec.ch/smartgrid/standards/</a>>.
[<a id="ref-IEC61850-7-4">IEC61850-7-4</a>]
"Compatible logical node classes and data classes",
<<a href="http://www.iec.ch/smartgrid/standards/">http://www.iec.ch/smartgrid/standards/</a>>.
<span class="grey">Parello, et al. Informational [Page 44]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-45" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
[<a id="ref-DMTF">DMTF</a>] "Power State Management Profile", DMTF DSP1027
Version 2.0.0, December 2009,
<<a href="http://www.dmtf.org/sites/default/files/standards/documents/DSP1027_2.0.0.pdf">http://www.dmtf.org/sites/default/files/standards/</a>
<a href="http://www.dmtf.org/sites/default/files/standards/documents/DSP1027_2.0.0.pdf">documents/DSP1027_2.0.0.pdf</a>>.
[<a id="ref-IPENERGY">IPENERGY</a>] Aldrich, R. and J. Parello, "IP-Enabled Energy Management:
A Proven Strategy for Administering Energy as a Service",
2010, Wiley Publishing.
[<a id="ref-X.700">X.700</a>] CCITT Recommendation X.700, "Management framework for Open
Systems Interconnection (OSI) for CCITT applications",
September 1992.
[<a id="ref-ASHRAE-201">ASHRAE-201</a>]
"ASHRAE Standard Project Committee 201 (SPC 201) Facility
Smart Grid Information Model",
<<a href="http://spc201.ashraepcs.org">http://spc201.ashraepcs.org</a>>.
[<a id="ref-CHEN">CHEN</a>] Chen, P., "The Entity-Relationship Model: Toward a Unified
View of Data", ACM Transactions on Database Systems
(TODS), March 1976.
[<a id="ref-CISCO-EW">CISCO-EW</a>] Parello, J., Saville, R., and S. Kramling, "Cisco
EnergyWise Design Guide", Cisco Validated Design (CVD),
September 2011,
<<a href="http://www.cisco.com/en/US/docs/solutions/Enterprise/Borderless_Networks/Energy_Management/energywisedg.html">http://www.cisco.com/en/US/docs/solutions/</a>
<a href="http://www.cisco.com/en/US/docs/solutions/Enterprise/Borderless_Networks/Energy_Management/energywisedg.html">Enterprise/Borderless_Networks/Energy_Management/</a>
<a href="http://www.cisco.com/en/US/docs/solutions/Enterprise/Borderless_Networks/Energy_Management/energywisedg.html">energywisedg.html</a>>.
<span class="h2"><a class="selflink" id="section-13" href="#section-13">13</a>. Acknowledgments</span>
The authors would like to thank Michael Brown for his editorial work,
which improved the text dramatically. Thanks to Rolf Winter for his
feedback, and to Bill Mielke for his feedback and very detailed
review. Thanks to Bruce Nordman for brainstorming, with numerous
conference calls and discussions. Finally, the authors would like to
thank the EMAN chairs: Nevil Brownlee, Bruce Nordman, and Tom Nadeau.
<span class="grey">Parello, et al. Informational [Page 45]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-46" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
<span class="h2"><a class="selflink" id="appendix-A" href="#appendix-A">Appendix A</a>. Information Model Listing</span>
A. EnergyObject (Class):
r index Integer An [<a href="./rfc6933" title=""Entity MIB (Version 4)"">RFC6933</a>] entPhysicalIndex
w name String An [<a href="./rfc6933" title=""Entity MIB (Version 4)"">RFC6933</a>] entPhysicalName
r identifier uuid An [<a href="./rfc6933" title=""Entity MIB (Version 4)"">RFC6933</a>] entPhysicalUUID
rw alternatekey String A manufacturer-defined string
that can be used to identify the
Energy Object
rw domainName String The name of an Energy Management
Domain for the Energy Object
rw role String An administratively assigned name
to indicate the purpose an
Energy Object serves in the
network
rw keywords String A list of keywords or [0..n] tags
that can be used to group Energy
Objects for reporting or
searching
rw importance Integer Specifies a ranking of how
important the Energy Object is
(on a scale of 1 to 100) compared
with other Energy Objects
rw relationships Relationship A list of relationships between
[0..n] this Energy Object and other
Energy Objects
r nameplate Nameplate The nominal PowerMeasurement of
the Energy Object as specified by
the device manufacturer
r power PowerMeasurement The present power measurement of
the Energy Object
r energy EnergyMeasurement The present energy measurement
for the Energy Object
r demand DemandMeasurement The present demand measurement
for the Energy Object
<span class="grey">Parello, et al. Informational [Page 46]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-47" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
r powerControl PowerStateSet A list of Power States Sets the
[0..n] Energy Object supports
B. PowerInterface (Class) inherits from EnergyObject:
r eoIfType Enumeration Indicates whether the Power
Interface is an inlet, outlet,
or both
C. Device (Class) inherits from EnergyObject:
rw eocategory Enumeration Broadly indicates whether
the Device is a producer,
consumer, meter, distributor,
or store of energy
r powerInterfaces PowerInterface A list of PowerInterfaces
[0..n] contained in this Device
r components Component A list of components
[0..n] contained in this Device
D. Component (Class) inherits from EnergyObject:
rw eocategory Enumeration Broadly indicates whether the
component is a producer,
consumer, meter, distributor, or
store of energy
r powerInterfaces PowerInterface A list of PowerInterfaces
[0..n] contained in this component
r components Component A list of components contained
[0..n] in this component
<span class="grey">Parello, et al. Informational [Page 47]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-48" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
E. Nameplate (Class):
r nominalPower PowerMeasurement The nominal power of the Energy
as specified by the device
manufacturer
rw details URI An [<a href="./rfc3986" title=""Uniform Resource Identifier (URI): Generic Syntax"">RFC3986</a>] URI that links to
manufacturer information about
the nominal power of a device
F. Relationship (Class):
rw relationshipType Enumeration A description of the
relationship, indicating
meters, meteredby, powers,
poweredby, aggregates, or
aggregatedby
rw relationshipObject uuid An [<a href="./rfc6933" title=""Entity MIB (Version 4)"">RFC6933</a>] entPhysicalUUID
that indicates the other
participating Energy Object in
the relationship
G. Measurement (Class):
r multiplier Enumeration The magnitude of the Measurement
in the range -24..24
r caliber Enumeration Specifies how the Measurement was
obtained -- actual, estimated, or
static
r accuracy Enumeration Specifies the accuracy of the
measurement, if applicable, as
0..10000, indicating hundreds of
percent
H. PowerMeasurement (Class) inherits from Measurement:
r value Long A measurement value of
power
r units "W" The units of measure for
the power -- "Watts"
<span class="grey">Parello, et al. Informational [Page 48]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-49" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
r powerAttribute PowerAttribute Measurement of the electrical
current -- voltage, phase, and/or
frequencies for the
PowerMeasurement
I. EnergyMeasurement (Class) inherits from Measurement:
r startTime Time Specifies the start time of the
EnergyMeasurement interval
r units "kWh" The units of measure for the energy --
kilowatt-hours
r provided Long A measurement of energy provided
r used Long A measurement of energy used/consumed
r produced Long A measurement of energy produced
r stored Long A measurement of energy stored
J. TimedMeasurement (Class) inherits from Measurement:
r startTime timestamp A start time of a measurement
r value Measurement A measurement value
r maximum Measurement A maximum value measured since a previous
timestamp
K. TimeInterval (Class):
r value Long A value of time
r units Enumeration A magnitude of time, expressed as seconds
with an SI prefix (milliseconds, etc.)
L. DemandMeasurement (Class) inherits from Measurement:
rw intervalLength TimeInterval The length of time over which to
compute average energy
rw intervals Long The number of intervals that can
be measured
<span class="grey">Parello, et al. Informational [Page 49]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-50" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
rw intervalMode Enumeration The mode of interval
measurement -- periodic, sliding,
or total
rw intervalWindow TimeInterval The duration between the starting
time of one sliding window and
the next starting time
rw sampleRate TimeInterval The sampling rate at which to
poll power in order to compute
demand
rw status Enumeration A control to start or stop demand
measurement -- active or inactive
r measurements TimedMeasurement A collection of TimedMeasurements
[0..n] to compute demand
M. PowerStateSet (Class):
r powerSetIdentifier Integer An IANA-assigned value indicating
a Power State Set
r name String A Power State Set name
r powerStates PowerState A set of Power States for the
[0..n] given identifier
rw operState Integer The current operational Power
State
rw adminState Integer The desired Power State
rw reason String Describes the reason
for the adminState
r configuredTime timestamp Indicates the time of
the desired Power State
N. PowerState (Class):
r powerStateIdentifier Integer An IANA-assigned value
indicating a Power State
r name String A name for the Power State
<span class="grey">Parello, et al. Informational [Page 50]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-51" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
r cardinality Integer A value indicating an
ordering of the Power State
rw maximumPower PowerMeasurement Indicates the maximum power
for the Energy Object at
this Power State
r totalTimeInState Time Indicates the total time
an Energy Object has been
in this Power State since
the last reset
r entryCount Long Indicates the number of
times the Energy Object
has entered or changed to
this state
O. PowerAttribute (Class):
r acQuality ACQuality Describes AC Power Attributes for
a Measurement
P. ACQuality (Class):
r acConfiguration Enumeration Describes the physical
configuration of alternating
current as single phase (SNGL),
three-phase delta (DEL), or
three-phase Y (WYE)
r avgVoltage Long The average of the voltage measured
over an integral number of AC
cycles [<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'Vol'
r avgCurrent Long The current per phase
[<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'Amp'
r thdCurrent Long A calculated value for the current
Total Harmonic Distortion (THD).
The method of calculation is not
specified [<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'ThdAmp'
r frequency Long Basic frequency of the AC circuit
[<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'Hz'
r unitMultiplier Integer Magnitude of watts for the usage
value in this instance
<span class="grey">Parello, et al. Informational [Page 51]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-52" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
r accuracy Integer Percentage value in 100ths
of a percent, representing the
presumed accuracy of active,
reactive, and apparent power
in this instance
r totalActivePower Long A measured value of the actual
power delivered to or consumed by
the load [<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'TotW'
r totalReactivePower Long A measured value of the reactive
portion of the apparent power
[<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'TotVAr'
r totalApparentPower Long A measured value of the voltage
and current, which determines the
apparent power as the vector sum of
real and reactive power
[<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'TotVA'
r totalPowerFactor Long A measured value of the ratio of
the real power flowing to the load
versus the apparent power
[<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'TotPF'
Q. DelPhase (Class) inherits from ACQuality:
r phaseToNext Long A measured value of phase to
PhaseVoltage next phase voltages where the
next phase is [<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>]
'PPV'
r thdVoltage Long A calculated value for the
voltage Total Harmonic Distortion
(THD) for phase to next phase.
The method of calculation is not
specified [<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'ThdPPV'
<span class="grey">Parello, et al. Informational [Page 52]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-53" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
R. WYEPhase (Class) inherits from ACQuality:
r phaseToNeutral Long A measured value of phase to
Voltage neutral voltage [<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>]
'PhV'
r thdCurrent Long A calculated value for the current
Total Harmonic Distortion (THD).
The method of calculation is not
specified [<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'ThdA'
r thdVoltage Long A calculated value of the voltage
THD for phase to neutral
[<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'ThdPhV'
r avgCurrent Long A measured value of phase currents
[<a href="#ref-IEC61850-7-4">IEC61850-7-4</a>] 'A'
<span class="grey">Parello, et al. Informational [Page 53]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-54" ></span>
<span class="grey"><a href="./rfc7326">RFC 7326</a> EMAN Framework September 2014</span>
Authors' Addresses
John Parello
Cisco Systems, Inc.
3550 Cisco Way
San Jose, CA 95134
US
Phone: +1 408 525 2339
EMail: jparello@cisco.com
Benoit Claise
Cisco Systems, Inc.
De Kleetlaan 6a b1
Diegem 1813
BE
Phone: +32 2 704 5622
EMail: bclaise@cisco.com
Brad Schoening
44 Rivers Edge Drive
Little Silver, NJ 07739
US
EMail: brad.schoening@verizon.net
Juergen Quittek
NEC Europe Ltd.
Network Laboratories
Kurfuersten-Anlage 36
69115 Heidelberg
Germany
Phone: +49 6221 90511 15
EMail: quittek@netlab.nec.de
Parello, et al. Informational [Page 54]
</pre>
|