1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797
|
<pre>Internet Engineering Task Force (IETF) D. Kumar
Request for Comments: 7784 S. Salam
Category: Standards Track Cisco
ISSN: 2070-1721 T. Senevirathne
February 2016
<span class="h1">Transparent Interconnection of Lots of Links (TRILL)</span>
<span class="h1">Operations, Administration, and Maintenance (OAM) MIB</span>
Abstract
This document specifies the MIB for the OAM (Operations,
Administration, and Maintenance) objects for IETF TRILL (Transparent
Interconnection of Lots of Links).
Status of This Memo
This is an Internet Standards Track document.
This document is a product of the Internet Engineering Task Force
(IETF). It represents the consensus of the IETF community. It has
received public review and has been approved for publication by the
Internet Engineering Steering Group (IESG). Further information on
Internet Standards is available in <a href="./rfc5741#section-2">Section 2 of RFC 5741</a>.
Information about the current status of this document, any errata,
and how to provide feedback on it may be obtained at
<a href="http://www.rfc-editor.org/info/rfc7784">http://www.rfc-editor.org/info/rfc7784</a>.
Copyright Notice
Copyright (c) 2016 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to <a href="https://www.rfc-editor.org/bcp/bcp78">BCP 78</a> and the IETF Trust's Legal
Provisions Relating to IETF Documents
(<a href="http://trustee.ietf.org/license-info">http://trustee.ietf.org/license-info</a>) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
<span class="grey">Kumar, et al. Standards Track [Page 1]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-2" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
Table of Contents
<a href="#section-1">1</a>. Introduction ....................................................<a href="#page-2">2</a>
<a href="#section-2">2</a>. The Internet-Standard Management Framework ......................<a href="#page-3">3</a>
<a href="#section-3">3</a>. Conventions .....................................................<a href="#page-3">3</a>
<a href="#section-4">4</a>. Overview ........................................................<a href="#page-4">4</a>
<a href="#section-5">5</a>. Structure of the MIB Module .....................................<a href="#page-4">4</a>
<a href="#section-5.1">5.1</a>. Textual Conventions ........................................<a href="#page-4">4</a>
<a href="#section-5.2">5.2</a>. The TRILL OAM MIB Subtree ..................................<a href="#page-4">4</a>
<a href="#section-5.3.1">5.3.1</a>. The Notifications Subtree ...........................<a href="#page-5">5</a>
<a href="#section-5.3.2">5.3.2</a>. The Table Structures ................................<a href="#page-5">5</a>
<a href="#section-5.3.2.1">5.3.2.1</a>. trillOamMepTable Objects ...................<a href="#page-5">5</a>
<a href="#section-5.3.2.2">5.3.2.2</a>. trillOamMepFlowCfgTable Objects ............<a href="#page-6">6</a>
<a href="#section-5.3.2.3">5.3.2.3</a>. trillOamPtrTable Objects ...................<a href="#page-6">6</a>
<a href="#section-5.3.2.4">5.3.2.4</a>. trillOamMtvrTable Objects ..................<a href="#page-6">6</a>
<a href="#section-5.3.2.5">5.3.2.5</a>. trillOamMepDbTable Objects .................<a href="#page-6">6</a>
<a href="#section-6">6</a>. Relationship to Other MIB Modules ...............................<a href="#page-6">6</a>
<a href="#section-6.1">6.1</a>. Relationship to the IEEE8021-TC-MIB ........................<a href="#page-7">7</a>
<a href="#section-6.2">6.2</a>. Relationship to the IEEE8021-CFM-MIB .......................<a href="#page-7">7</a>
<a href="#section-6.3">6.3</a>. MIB Modules Required for IMPORTS ...........................<a href="#page-8">8</a>
<a href="#section-7">7</a>. Definitions .....................................................<a href="#page-8">8</a>
<a href="#section-8">8</a>. Security Considerations ........................................<a href="#page-44">44</a>
<a href="#section-9">9</a>. IANA Considerations ............................................<a href="#page-47">47</a>
<a href="#section-10">10</a>. References ....................................................<a href="#page-47">47</a>
<a href="#section-10.1">10.1</a>. Normative References .....................................<a href="#page-47">47</a>
<a href="#section-10.2">10.2</a>. Informative References ...................................<a href="#page-49">49</a>
Acknowledgments ...................................................<a href="#page-50">50</a>
Authors' Addresses ................................................<a href="#page-50">50</a>
<span class="h2"><a class="selflink" id="section-1" href="#section-1">1</a>. Introduction</span>
Overall, TRILL OAM meets the requirements given in [<a href="./rfc6905" title=""Requirements for Operations, Administration, and Maintenance (OAM) in Transparent Interconnection of Lots of Links (TRILL)"">RFC6905</a>]. The
general framework for TRILL OAM is specified in [<a href="./rfc7174" title=""Transparent Interconnection of Lots of Links (TRILL) Operations, Administration, and Maintenance (OAM) Framework"">RFC7174</a>]. The
details of the Fault Management (FM) solution, conforming to that
framework, are presented in [<a href="./rfc7455" title=""Transparent Interconnection of Lots of Links (TRILL): Fault Management"">RFC7455</a>]. The solution leverages the
message format defined in Ethernet Connectivity Fault Management
(CFM) [<a href="#ref-802.1Q" title=""IEEE Standard for Local and metropolitan area networks -- Media Access Control (MAC) Bridges and Virtual Bridge Local Area Networks"">802.1Q</a>] as the basis for the TRILL OAM message channel.
This document uses the CFM MIB modules defined in [<a href="#ref-802.1Q" title=""IEEE Standard for Local and metropolitan area networks -- Media Access Control (MAC) Bridges and Virtual Bridge Local Area Networks"">802.1Q</a>] as the
basis for TRILL OAM MIB and augments the existing tables to add new
TRILL managed objects required by TRILL. This document further
specifies a new table with associated managed objects for TRILL OAM-
specific capabilities.
<span class="grey">Kumar, et al. Standards Track [Page 2]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-3" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
<span class="h2"><a class="selflink" id="section-2" href="#section-2">2</a>. The Internet-Standard Management Framework</span>
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to <a href="./rfc3410#section-7">section 7 of
RFC 3410</a> [<a href="./rfc3410" title=""Introduction and Applicability Statements for Internet- Standard Management Framework"">RFC3410</a>].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies a MIB
module that is compliant to the SMIv2, which is described in STD 58,
<a href="./rfc2578">RFC 2578</a> [<a href="./rfc2578" title=""Structure of Management Information Version 2 (SMIv2)"">RFC2578</a>], STD 58, <a href="./rfc2579">RFC 2579</a> [<a href="./rfc2579" title=""Textual Conventions for SMIv2"">RFC2579</a>] and STD 58, <a href="./rfc2580">RFC 2580</a>
[<a href="./rfc2580" title=""Conformance Statements for SMIv2"">RFC2580</a>].
<span class="h2"><a class="selflink" id="section-3" href="#section-3">3</a>. Conventions</span>
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
"OPTIONAL" in this document are to be interpreted as described in <a href="./rfc2119">RFC</a>
<a href="./rfc2119">2119</a> [<a href="./rfc2119" title=""Key words for use in RFCs to Indicate Requirement Levels"">RFC2119</a>].
Abbreviations used in the document include the following:
CCM - Continuity Check Message [<a href="#ref-802.1Q" title=""IEEE Standard for Local and metropolitan area networks -- Media Access Control (MAC) Bridges and Virtual Bridge Local Area Networks"">802.1Q</a>]
EMS - Element Management System [<a href="#ref-Q.840.1" title=""Requirements and analysis for NMS-EMS management interface of Ethernet over Transport and Metro Ethernet Network (EoT/MEN)"">Q.840.1</a>]
MEP - Maintenance End Point [<a href="./rfc7174" title=""Transparent Interconnection of Lots of Links (TRILL) Operations, Administration, and Maintenance (OAM) Framework"">RFC7174</a>] [<a href="#ref-802.1Q" title=""IEEE Standard for Local and metropolitan area networks -- Media Access Control (MAC) Bridges and Virtual Bridge Local Area Networks"">802.1Q</a>]
MIP - Maintenance Intermediate Point [<a href="./rfc7174" title=""Transparent Interconnection of Lots of Links (TRILL) Operations, Administration, and Maintenance (OAM) Framework"">RFC7174</a>] [<a href="#ref-802.1Q" title=""IEEE Standard for Local and metropolitan area networks -- Media Access Control (MAC) Bridges and Virtual Bridge Local Area Networks"">802.1Q</a>]
MP - Maintenance Point [<a href="./rfc7174" title=""Transparent Interconnection of Lots of Links (TRILL) Operations, Administration, and Maintenance (OAM) Framework"">RFC7174</a>]
MTVM - Multi-destination Tree Verification Message [<a href="./rfc7455" title=""Transparent Interconnection of Lots of Links (TRILL): Fault Management"">RFC7455</a>]
MTVR - Multi-destination Tree Verification Reply [<a href="./rfc7455" title=""Transparent Interconnection of Lots of Links (TRILL): Fault Management"">RFC7455</a>]
NMS - Network Management System [<a href="#ref-Q.840.1" title=""Requirements and analysis for NMS-EMS management interface of Ethernet over Transport and Metro Ethernet Network (EoT/MEN)"">Q.840.1</a>]
PTM - Path Trace Message [<a href="./rfc7455" title=""Transparent Interconnection of Lots of Links (TRILL): Fault Management"">RFC7455</a>]
PTR - Path Trace Reply [<a href="./rfc7455" title=""Transparent Interconnection of Lots of Links (TRILL): Fault Management"">RFC7455</a>]
<span class="grey">Kumar, et al. Standards Track [Page 3]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-4" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
<span class="h2"><a class="selflink" id="section-4" href="#section-4">4</a>. Overview</span>
The TRILL OAM MIB module provides an overall framework for managing
TRILL OAM. It leverages the IEEE8021-CFM-MIB and IEEE8021-CFM-V2-MIB
modules defined in [<a href="#ref-802.1Q" title=""IEEE Standard for Local and metropolitan area networks -- Media Access Control (MAC) Bridges and Virtual Bridge Local Area Networks"">802.1Q</a>], and it augments the Maintenance End
Point (MEP) and MEP Db entries. It also adds a new table for
messages specific to TRILL OAM.
<span class="h2"><a class="selflink" id="section-5" href="#section-5">5</a>. Structure of the MIB Module</span>
Objects in this MIB module are arranged into subtrees. Each subtree
is organized as a set of related objects. The various subtrees are
shown below, supplemented with the required elements of the
IEEE8021-CFM-MIB module.
<span class="h3"><a class="selflink" id="section-5.1" href="#section-5.1">5.1</a>. Textual Conventions</span>
Textual conventions are defined to represent object types relevant to
the TRILL OAM MIB.
<span class="h3"><a class="selflink" id="section-5.2" href="#section-5.2">5.2</a>. The TRILL OAM MIB Subtree</span>
The TRILL OAM MIB tree described below consists of
trilloamNotifications (Traps) and trillOamMibObjects. The
trilloamNotifications are sent to the management entity whenever a
MEP loses/restores contact with its peer flow MEPs.
The TRILL OAM MIB per MEP Objects are defined in the
trillOamMepTable. The trillOamMepTable augments the
dot1agCfmMepEntry (please see <a href="#section-6.1">Section 6.1</a>) defined in
IEEE8021-CFM-MIB. It includes objects that are locally defined for
an individual MEP and its associated flow.
<span class="grey">Kumar, et al. Standards Track [Page 4]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-5" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
TRILL-OAM-MIB
|--trillOamNotifications (trillOamMib 0}
|--trillOamFaultAlarm
|--trillOamMibObjects {trillOamMib 1}
|--trillOamMep {trillOamMibObjects 1}
|--trillOamMepTable {trillOamMep 1} - Local TRLL config
|--trillOamMepFlowCfgTable
|--trillOamPtrTable
|--trillOamMtvrTable
|--trillOamMepDbTable
<span class="h4"><a class="selflink" id="section-5.3.1" href="#section-5.3.1">5.3.1</a>. The Notifications Subtree</span>
Notifications (fault alarms) are sent to the management entity with
the OID of the MEP that has detected the fault. Notifications are
generated whenever MEP loses/restores contact with its peer flow
MEPs.
<span class="h4"><a class="selflink" id="section-5.3.2" href="#section-5.3.2">5.3.2</a>. The Table Structures</span>
The TRILL OAM MIB per MEP Objects are defined in the
trillOamMepTable. The trillOamMepTable augments the
dot1agCfmMepEntry (please see <a href="#section-6.1">Section 6.1</a>) defined in
IEEE8021-CFM-MIB. It includes objects that are locally defined for
an individual MEP and its associated flow.
<span class="h5"><a class="selflink" id="section-5.3.2.1" href="#section-5.3.2.1">5.3.2.1</a>. trillOamMepTable Objects</span>
This table is an extension of the dot1agCfmMepTable. Rows are
automatically added or deleted from this table based upon row
creation and destruction of the dot1agCfmMepTable.
This table represents the local MEP TRILL OAM configuration table.
The primary purpose of this table is provide local parameters for the
TRILL OAM function found in [<a href="./rfc7455" title=""Transparent Interconnection of Lots of Links (TRILL): Fault Management"">RFC7455</a>] and instantiated at a MEP.
<span class="grey">Kumar, et al. Standards Track [Page 5]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-6" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
<span class="h5"><a class="selflink" id="section-5.3.2.2" href="#section-5.3.2.2">5.3.2.2</a>. trillOamMepFlowCfgTable Objects</span>
Each row in this table represents a Flow Configuration Entry for the
associated MEP. This table uses four indices. The first three
indices are the indices of the Maintenance Domain, MANET, and MEP
tables. The fourth index is the specific Flow Configuration Entry on
the selected MEP. Some writable objects in this table are only
applicable in certain cases (as described under each object below),
and attempts to write values for them in other cases will be ignored.
<span class="h5"><a class="selflink" id="section-5.3.2.3" href="#section-5.3.2.3">5.3.2.3</a>. trillOamPtrTable Objects</span>
Each row in this table represents a Path Trace Reply Entry for the
Defined MEP and Transaction. This table uses four indices. The
first three indices identify the MEP and the fourth index specifies
the Transaction Identifier. This Transaction Identifier uniquely
identifies the response for a MEP, which can have multiple flows.
<span class="h5"><a class="selflink" id="section-5.3.2.4" href="#section-5.3.2.4">5.3.2.4</a>. trillOamMtvrTable Objects</span>
This table includes managed objects for the Multi-destination Reply.
Each row in the table represents a Multi-destination Reply Entry for
the defined MEP and Transaction. This table uses the following five
indices: 1) Maintenance Domain, 2) MANET, 3) MEP tables, 4)
Transaction Identifier of selected MEP, and 5) receive order of
Multi-destination replies.
Some writable objects in this table are only applicable in certain
cases (as described under each object below), and attempts to write a
value for them in other cases will be ignored.
<span class="h5"><a class="selflink" id="section-5.3.2.5" href="#section-5.3.2.5">5.3.2.5</a>. trillOamMepDbTable Objects</span>
This table is an augmentation of the dot1agCfmMepDbTable, and rows
are automatically added or deleted from this table based upon row
creation and destruction of the dot1agCfmMepDbTable.
<span class="h2"><a class="selflink" id="section-6" href="#section-6">6</a>. Relationship to Other MIB Modules</span>
The IEEE8021-CFM-MIB [<a href="#ref-IEEE8021-CFM-MIB">IEEE8021-CFM-MIB</a>] and [<a href="#ref-LLDP-MIB" title=""Management Information Base module for LLDP configuration, statistics, local system data and remote systems data components"">LLDP-MIB</a>] contain
objects that are relevant to the TRILL OAM MIB. Management objects
contained in these modules are not duplicated here, to reduce overlap
to the extent possible. From the IEEE8021-CFM-MIB, the following
objects are imported:
o dot1agCfmMdIndex
o dot1agCfmMaIndex
<span class="grey">Kumar, et al. Standards Track [Page 6]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-7" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
o dot1agCfmMepIdentifier
o dot1agCfmMepEntry
o dot1agCfmMepDbEntry
o Dot1agCfmIngressActionFieldValue
o Dot1agCfmEgressActionFieldValue
o Dot1agCfmRemoteMepState
From the [<a href="#ref-LLDP-MIB" title=""Management Information Base module for LLDP configuration, statistics, local system data and remote systems data components"">LLDP-MIB</a>], the following objects are imported:
o LldpChassisId
o LldpChassisIdSubtype
o LldpPortId
<span class="h3"><a class="selflink" id="section-6.1" href="#section-6.1">6.1</a>. Relationship to the IEEE8021-TC-MIB</span>
In TRILL, traffic labeling can be done using either a 12-bit VLAN or
a 24-bit Fine-Grained Label (FGL) [<a href="./rfc7172" title=""Transparent Interconnection of Lots of Links (TRILL): Fine-Grained Labeling"">RFC7172</a>].
The IEEE8021-TC-MIB definition of IEEE8021ServiceSelectorType
includes the following two values:
- 1 representing a vlanId, and
- 2 representing a 24-bit isid
We have chosen to use value 2 for TRILL's FGL. As such, TRILL OAM
MIB will import IEEE8021ServiceSelectorType,
IEEE8021ServiceSelectorValueOrNone, and IEEE8021ServiceSelectorValue
from IEEE8021-TC-MIB.
<span class="h3"><a class="selflink" id="section-6.2" href="#section-6.2">6.2</a>. Relationship to the IEEE8021-CFM-MIB</span>
trillOamMepTable augments dot1agCfmMepEntry. Implementation of
IEEE8021-CFM-MIB is required as we are augmenting the IEEE-CFM-MIB
Table. Objects/Tables that are not applicable to a TRILL
implementation have to be handled by the TRILL implementation
backend, and appropriate default values, as described in
IEEE8021-CFM-MIB, have to be returned.
<span class="grey">Kumar, et al. Standards Track [Page 7]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-8" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
The TRILL OAM implementation doesn't support the Link Trace Message
or Link Trace Reply, since, as described in <a href="./rfc7455">RFC 7455</a>, the Path Trace
Message and Reply for unicast traffic and Multi-destination Tree
verification Message and Reply for multicast traffic have been
substituted for them. Statistics for these messages should default
as per IEEE8021-CFM-MIB.
<span class="h3"><a class="selflink" id="section-6.3" href="#section-6.3">6.3</a>. MIB Modules Required for IMPORTS</span>
The following MIB module IMPORTS objects from SNMPv2-SMI [<a href="./rfc2578" title=""Structure of Management Information Version 2 (SMIv2)"">RFC2578</a>],
SNMPv2-TC [<a href="./rfc2579" title=""Textual Conventions for SMIv2"">RFC2579</a>], SNMPv2-CONF [<a href="./rfc2580" title=""Conformance Statements for SMIv2"">RFC2580</a>], IEEE-8021-CFM-MIB, and
LLDP-MIB.
<span class="h2"><a class="selflink" id="section-7" href="#section-7">7</a>. Definitions</span>
TRILL-OAM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Counter32,
Unsigned32,
Integer32,
mib-2,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
RowStatus,
TruthValue,
TimeStamp,
MacAddress
FROM SNMPv2-TC
OBJECT-GROUP,
NOTIFICATION-GROUP,
MODULE-COMPLIANCE
FROM SNMPv2-CONF
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
dot1agCfmMepEntry,
dot1agCfmMepDbEntry,
Dot1agCfmIngressActionFieldValue,
Dot1agCfmEgressActionFieldValue,
Dot1agCfmRemoteMepState
FROM IEEE8021-CFM-MIB
LldpChassisId,
LldpChassisIdSubtype,
LldpPortId,
<span class="grey">Kumar, et al. Standards Track [Page 8]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-9" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
LldpPortIdSubtype
FROM LLDP-MIB;
trillOamMib MODULE-IDENTITY
LAST-UPDATED "201601141200Z"
ORGANIZATION "IETF TRILL WG"
CONTACT-INFO
"Email: trill@ietf.org"
DESCRIPTION
"This MIB module contains the management objects for the
management of TRILL Services Operations, Administration
and Maintenance.
Initial version. Published as <a href="./rfc7784">RFC 7784</a>.
Copyright (c) 2016 IETF Trust and the persons identified
as authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with
or without modification, is permitted pursuant to, and
subject to the license terms contained in, the Simplified
BSD License set forth in <a href="#section-4">Section 4</a>.c of the IETF Trust's
Legal Provisions Relating to IETF Documents
(<a href="http://trustee.ietf.org/license-info">http://trustee.ietf.org/license-info</a>).
<span class="grey">Kumar, et al. Standards Track [Page 9]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-10" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
-------------------------------------------------------------
Abbreviations Used
Term Definition
CFM Connectivity Fault Management
IEEE Institute of Electrical and Electronics
Engineers
IETF Internet Engineering Task Force
ITU-T International Telecommunication Union -
Telecommunication Standardization Bureau
FCOI The Final, Cross-Connect Error, Out-of-band,
and In-band flags from the TRILL OAM Application
Identifier TLV.
LBM Loopback Message
MA Maintenance Association (equivalent to a MEG)
MAC Media Access Control
MD Maintenance Domain (equivalent to an OAM
Domain in Metro Ethernet Forum (MEF) 17)
MEG Maintenance Entity Group (equivalent to a MA)
MEG Level Maintenance Entity Group Level (equivalent to
MD Level)
MEP Maintenance Association End Point
MIB Management Information Base
MIP Maintenance Domain Intermediate Point
MTVM Multi-destination Tree Verification Message
MTVR Multi-destination Tree Verification Reply
OAM Operations, Administration, and Maintenance
On-Demand OAM actions that are initiated via
manual intervention for a limited time to carry
out diagnostics. On-demand OAM can result in
singular or periodic OAM actions during the
diagnostic time interval.
PTM Path Trace Message
PTR Path Trace Reply
RFC Request for Comments
SNMP Simple Network Management Protocol
TLV Type-Length-Value, a method of encoding Objects
TRILL Transparent Interconnection of Lots of Links
VLAN Virtual LAN"
REVISION "201601141200Z"
DESCRIPTION
"Initial version. Published as <a href="./rfc7784">RFC 7784</a>."
::= { mib-2 238 }
--
<span class="grey">Kumar, et al. Standards Track [Page 10]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-11" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
-- *****************************************************************
-- Object Definitions in the TRILL OAM MIB Module
-- *****************************************************************
trillOamNotifications OBJECT IDENTIFIER
::= { trillOamMib 0 }
trillOamMibObjects OBJECT IDENTIFIER
::= { trillOamMib 1 }
trillOamMibConformance OBJECT IDENTIFIER
::= { trillOamMib 2 }
-- *****************************************************************
-- Groups in the TRILL OAM MIB Module
-- *****************************************************************
trillOamMep OBJECT IDENTIFIER
::= { trillOamMibObjects 1 }
-- *****************************************************************
-- TRILL OAM MEP Configuration
-- *****************************************************************
trillOamMepTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrillOamMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of the dot1agCfmMepTable and
rows are automatically added or deleted from this table
based upon row creation and destruction of the
dot1agCfmMepTable.
This table represents the local MEP TRILL OAM
configuration table. The primary purpose of this table
is provide local parameters for the TRILL OAM function
found in <a href="./rfc7455">RFC 7455</a> and instantiated at a MEP."
REFERENCE "<a href="./rfc7455">RFC 7455</a>"
::= { trillOamMep 1 }
trillOamMepEntry OBJECT-TYPE
SYNTAX TrillOamMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row of trillOamMepTable."
AUGMENTS { dot1agCfmMepEntry }
::= { trillOamMepTable 1 }
<span class="grey">Kumar, et al. Standards Track [Page 11]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-12" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
TrillOamMepEntry ::= SEQUENCE {
trillOamMepRName Unsigned32,
trillOamMepNextPtmTId Counter32,
trillOamMepNextMtvmTId Counter32,
trillOamMepPtrIn Counter32,
trillOamMepPtrInOutofOrder Counter32,
trillOamMepPtrOut Counter32,
trillOamMepMtvrIn Counter32,
trillOamMepMtvrInOutofOrder Counter32,
trillOamMepMtvrOut Counter32,
trillOamMepTxLbmDestRName Unsigned32,
trillOamMepTxLbmHC Unsigned32,
trillOamMepTxLbmReplyModeOob TruthValue,
trillOamMepTransmitLbmReplyIp OCTET STRING,
trillOamMepTxLbmFlowEntropy OCTET STRING,
trillOamMepTxPtmDestRName Unsigned32,
trillOamMepTxPtmHC Unsigned32,
trillOamMepTxPtmReplyModeOob TruthValue,
trillOamMepTransmitPtmReplyIp OCTET STRING,
trillOamMepTxPtmFlowEntropy OCTET STRING,
trillOamMepTxPtmStatus TruthValue,
trillOamMepTxPtmResultOK TruthValue,
trillOamMepTxPtmSeqNumber Unsigned32,
trillOamMepTxPtmMessages Integer32,
trillOamMepTxMtvmTree Unsigned32,
trillOamMepTxMtvmHC Unsigned32,
trillOamMepTxMtvmReplyModeOob TruthValue,
trillOamMepTransmitMtvmReplyIp OCTET STRING,
trillOamMepTxMtvmFlowEntropy OCTET STRING,
trillOamMepTxMtvmStatus TruthValue,
trillOamMepTxMtvmResultOK TruthValue,
trillOamMepTxMtvmMessages Integer32,
trillOamMepTxMtvmSeqNumber Unsigned32,
trillOamMepTxMtvmScopeList OCTET STRING,
trillOamMepDiscontinuityTime TimeStamp
}
trillOamMepRName OBJECT-TYPE
SYNTAX Unsigned32 (0..65471)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the RBridge Nickname field
of the TRILL RBridge as defined in <a href="./rfc6325#section-3.7">RFC 6325,
Section 3.7</a>."
REFERENCE "<a href="./rfc7455">RFC 7455</a> and <a href="./rfc6325#section-3.7">RFC 6325, Section 3.7</a>"
::= { trillOamMepEntry 1 }
<span class="grey">Kumar, et al. Standards Track [Page 12]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-13" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMepNextPtmTId OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Next Sequence Number / Transaction Identifier to be sent in
a Multi-destination message. This Sequence Number can be
zero because it wraps around. Implementation of this
identifier should be should provide a unique code value in
order to identify the Transaction Identifier for a MEP with
multiple flows."
REFERENCE "<a href="./rfc7455#section-10.1.1">RFC 7455, Section 10.1.1</a>"
::= { trillOamMepEntry 2 }
trillOamMepNextMtvmTId OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Next Sequence Number / Transaction Identifier to be sent
in a Multi-destination message. This Sequence Number can
be zero because it wraps around. An implementation should
be unique to identify Transaction Identifier for a MEP with
multiple flows."
REFERENCE "<a href="./rfc7455#section-11.2.1">RFC 7455, Section 11.2.1</a>"
::= { trillOamMepEntry 3 }
trillOamMepPtrIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of valid, in-order Path Trace Replies
received."
REFERENCE "<a href="./rfc7455#section-10">RFC 7455, Section 10</a>"
::= { trillOamMepEntry 4 }
trillOamMepPtrInOutofOrder OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of valid, out-of-order Path Trace Replies
received."
REFERENCE "<a href="./rfc7455#section-10">RFC 7455, Section 10</a>"
::= { trillOamMepEntry 5 }
<span class="grey">Kumar, et al. Standards Track [Page 13]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-14" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMepPtrOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of valid, Path Trace Replies
transmitted."
REFERENCE "<a href="./rfc7455#section-10">RFC 7455, Section 10</a>"
::= { trillOamMepEntry 6 }
trillOamMepMtvrIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of valid, in-order Multi-destination
Replies received."
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
::= { trillOamMepEntry 7 }
trillOamMepMtvrInOutofOrder OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of valid, out-of-order Multi-destination
Replies received."
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
::= { trillOamMepEntry 8 }
trillOamMepMtvrOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of valid, Multi-destination Replies
transmitted."
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
::= { trillOamMepEntry 9 }
trillOamMepTxLbmDestRName OBJECT-TYPE
SYNTAX Unsigned32 (0..65471)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Target Destination RBridge Nickname field, as
defined in <a href="./rfc6325#section-3.7">RFC 6325, Section 3.7</a>, to be transmitted."
REFERENCE "<a href="./rfc7455">RFC 7455</a> and <a href="./rfc6325#section-3.7">RFC 6325, Section 3.7</a>"
<span class="grey">Kumar, et al. Standards Track [Page 14]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-15" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
::= { trillOamMepEntry 10 }
trillOamMepTxLbmHC OBJECT-TYPE
SYNTAX Unsigned32(1..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Hop Count field to be transmitted."
REFERENCE "<a href="./rfc7455">RFC 7455</a>, Sections <a href="#section-3">3</a> and <a href="#section-9">9</a>"
::= { trillOamMepEntry 11 }
trillOamMepTxLbmReplyModeOob OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"True indicates that the Reply to an LBM is out of
band and the out-of-band IP Address TLV is to be
transmitted. False indicates that in-band reply is
transmitted."
REFERENCE "<a href="./rfc7455#section-9.2.1">RFC 7455, Section 9.2.1</a>"
::= { trillOamMepEntry 12 }
trillOamMepTransmitLbmReplyIp OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4..16))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP address for an out-of-band IP Address TLV
that is to be transmitted. Maximum length for IPv6
is 16 octets and IPv4 is 4 octets."
REFERENCE "<a href="./rfc7455#section-3">RFC 7455, Section 3</a>"
::= { trillOamMepEntry 13 }
trillOamMepTxLbmFlowEntropy OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (96))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"96-byte Flow Entropy, as defined in <a href="./rfc7455">RFC 7455</a>, to
be transmitted."
REFERENCE "<a href="./rfc7455#section-3">RFC 7455, Section 3</a>"
::= { trillOamMepEntry 14 }
trillOamMepTxPtmDestRName OBJECT-TYPE
SYNTAX Unsigned32 (0..65471)
MAX-ACCESS read-create
STATUS current
<span class="grey">Kumar, et al. Standards Track [Page 15]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-16" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
DESCRIPTION
"The Target Destination RBridge Nickname field,
as defined in <a href="./rfc6325#section-3.7">RFC 6325, Section 3.7</a>, to be transmitted."
REFERENCE "<a href="./rfc7455">RFC 7455</a> and <a href="./rfc6325#section-3.7">RFC 6325, Section 3.7</a>"
::= { trillOamMepEntry 15 }
trillOamMepTxPtmHC OBJECT-TYPE
SYNTAX Unsigned32 (1..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Hop Count field to be transmitted."
REFERENCE "<a href="./rfc7455#section-3">RFC 7455, Section 3</a>"
::= { trillOamMepEntry 16 }
trillOamMepTxPtmReplyModeOob OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"True indicates that a Reply to a PTM will be
out of band and the out-of-band IP Address TLV
is to be transmitted. False indicates that an
in-band reply is transmitted."
REFERENCE "<a href="./rfc7455#section-10">RFC 7455, Section 10</a>"
DEFVAL { false }
::= { trillOamMepEntry 17 }
trillOamMepTransmitPtmReplyIp OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4..16))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP address for an out-of-band IP Address TLV
to be transmitted. The maximum length for an
IPv6 address is 16 octets. The maximum length
for an IPv4 address is 4 octets."
REFERENCE "<a href="./rfc7455">RFC 7455</a>, Sections <a href="#section-3">3</a> and <a href="#section-10">10</a>"
::= { trillOamMepEntry 18 }
trillOamMepTxPtmFlowEntropy OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (96))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"96-byte Flow Entropy, as defined in <a href="./rfc7455">RFC 7455</a>, to be
transmitted."
REFERENCE "<a href="./rfc7455#section-3">RFC 7455, Section 3</a>"
<span class="grey">Kumar, et al. Standards Track [Page 16]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-17" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
::= { trillOamMepEntry 19 }
trillOamMepTxPtmStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A Boolean flag set to TRUE by the MEP Path Trace Initiator
State Machine or a MIB manager to indicate that another PTM
is being transmitted. This is reset to FALSE by the MEP
Initiator State Machine. The PTM managed objects in the MEP
table are used in a manner similar to that described for LBM
transmission in the dot1agCfmMepTable. As per <a href="./rfc7455#section-10">RFC 7455,
Section 10</a>, operation of the Path Trace Message is identical
to the Loopback message except that it is first transmitted
with a TRILL Header Hop Count field value of 1 and then
retransmitted with an incrementing Hop Count until a
response is received from the destination RBridge, or the
Hop Count reaches a configured maximum value. The
trillOamMepTxPtmStatus status is reset to FALSE by
the initiator when the last PTM is transmitted."
REFERENCE "<a href="./rfc7455#section-10">RFC 7455, Section 10</a>"
DEFVAL { false }
::= { trillOamMepEntry 20 }
trillOamMepTxPtmResultOK OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the following results of the operation:
- true indicates the Path Trace Message(s) will be
(or has been) sent.
- false indicates the Path Trace Message(s) will not
be sent."
REFERENCE "<a href="./rfc7455#section-10">RFC 7455, Section 10</a>"
DEFVAL { true }
::= { trillOamMepEntry 21 }
trillOamMepTxPtmSeqNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Path Trace Transaction Identifier of the first
PTM (to be) sent. The value returned is
undefined if trillOamMepTxPtmResultOK is false."
REFERENCE "<a href="./rfc7455#section-10">RFC 7455, Section 10</a>"
<span class="grey">Kumar, et al. Standards Track [Page 17]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-18" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
::= { trillOamMepEntry 22 }
trillOamMepTxPtmMessages OBJECT-TYPE
SYNTAX Integer32 (1..1024)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of Path Trace messages to be transmitted.
As per <a href="./rfc7455#section-10">RFC 7455, Section 10</a>, the first Path Trace
Message is transmitted with a Hop Count of 1; an
RBridge may continue to retransmit the request at
periodic intervals with an incrementing Hop Count
until a response is received from the destination
RBridge or the Hop Count reaches a configured
maximum value. The event of the Destination
response being received or the Hop Count reaching
its maximum is treated as a single Counter
increment of this object."
REFERENCE "<a href="./rfc7455#section-10">RFC 7455, Section 10</a>"
::= { trillOamMepEntry 23 }
trillOamMepTxMtvmTree OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Multi-destination Tree identifier, as
defined in <a href="./rfc6325">RFC 6325</a>, for an MTVM."
::= { trillOamMepEntry 24 }
trillOamMepTxMtvmHC OBJECT-TYPE
SYNTAX Unsigned32(1..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Hop Count field to be transmitted.
"
REFERENCE "<a href="./rfc7455#section-3">RFC 7455, Section 3</a>, and <a href="./rfc6325#section-3">RFC 6325, Section 3</a>"
::= { trillOamMepEntry 25 }
trillOamMepTxMtvmReplyModeOob OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"True indicates that the reply to an MTVM is out of
band and this out-of-band IP Address TLV is where the
reply is to be transmitted.
<span class="grey">Kumar, et al. Standards Track [Page 18]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-19" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
False indicates that an in-band reply is transmitted."
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
::= { trillOamMepEntry 26 }
trillOamMepTransmitMtvmReplyIp OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4..16))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP address for an out-of-band IP Address TLV that is
to be transmitted. The maximum length for IPv6 is 16
octets and IPv4 is 4 octets."
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
::= { trillOamMepEntry 27 }
trillOamMepTxMtvmFlowEntropy OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (96))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"96-byte Flow Entropy, as defined in <a href="./rfc7455">RFC 7455</a>, to be
transmitted."
REFERENCE "<a href="./rfc7455#section-3">RFC 7455, Section 3</a>"
::= { trillOamMepEntry 28 }
trillOamMepTxMtvmStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A Boolean flag set to TRUE by the MEP Multi-destination
Initiator State Machine or a MIB manager to indicate
that another MTVM is being transmitted.
Reset to FALSE by the MEP Initiator State Machine.
The MTVM-managed objects in the MEP table are used
in a manner similar to that described for LBM
transmission in the dot1agCfmMepTable. As per <a href="./rfc7455#section-11">RFC 7455,
Section 11</a>, operation of the MTVM is
identical to the Loopback message except that it is
first transmitted with a TRILL Header Hop Count
field value of 1 and it is retransmitted incrementing
the Hop Count until a response is received from the
destination RBridge or the Hop Count reaches a
configured maximum value. The trillOamMepTxMtvmStatus
Status is reset to FALSE by the initiator when the last
MTVM is transmitted."
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
DEFVAL { false }
<span class="grey">Kumar, et al. Standards Track [Page 19]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-20" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
::= { trillOamMepEntry 29 }
trillOamMepTxMtvmResultOK OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the result of the operation in
the following way:
- true indicates the Multi-destination Message(s) will be
(or has been) sent.
- false indicates the Multi-destination Message(s) will not
be sent."
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
DEFVAL { true }
::= { trillOamMepEntry 30 }
trillOamMepTxMtvmMessages OBJECT-TYPE
SYNTAX Integer32 (1..1024)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of Multi-destination messages to be transmitted.
The RBridge transmit the Multi-destination message
incrementing the session Identification Number at periodic
interval until this count expires."
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
::= { trillOamMepEntry 31 }
trillOamMepTxMtvmSeqNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Multi-destination Transaction Identifier of the
first MTVM (to be)
sent. The value returned is undefined if
trillOamMepTxMtvmResultOK is false."
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
::= { trillOamMepEntry 32 }
trillOamMepTxMtvmScopeList OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Multi-destination RBridge Scope list, which
requires 2 octets per RBridge."
<span class="grey">Kumar, et al. Standards Track [Page 20]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-21" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
::= { trillOamMepEntry 33 }
trillOamMepDiscontinuityTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of the value of the sysUpTime object at the
beginning of the latest period of continuity of the
statistical counters associated with this MEP."
::= { trillOamMepEntry 34 }
-- *****************************************************************
-- TRILL OAM Tx Measurement Configuration Table
-- *****************************************************************
trillOamMepFlowCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrillOamMepFlowCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes configuration objects and operations
for the TRILL OAM facilities in <a href="./rfc7455">RFC 7455</a>.
Each row in the table represents a Flow Configuration
Entry for the defined MEP. This table uses four indices.
The first three indices are the indices of the Maintenance
Domain, MANET, and MEP tables. The fourth index is the
specific Flow Configuration Entry on the selected MEP.
Some writable objects in this table are only applicable in
certain cases (as described under each object), and
attempts to write values for them in other cases
will be ignored."
REFERENCE "<a href="./rfc7455">RFC 7455</a>"
::= { trillOamMep 2 }
trillOamMepFlowCfgEntry OBJECT-TYPE
SYNTAX TrillOamMepFlowCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row of trillOamMepFlowCfgTable."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
<span class="grey">Kumar, et al. Standards Track [Page 21]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-22" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMepFlowCfgIndex
}
::= { trillOamMepFlowCfgTable 1 }
TrillOamMepFlowCfgEntry ::= SEQUENCE {
trillOamMepFlowCfgIndex Unsigned32,
trillOamMepFlowCfgFlowEntropy OCTET STRING,
trillOamMepFlowCfgDestRName Unsigned32,
trillOamMepFlowCfgFlowHC Unsigned32,
trillOamMepFlowCfgRowStatus RowStatus
}
trillOamMepFlowCfgIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index to the TRILL OAM MEP Flow Configuration table,
which indicates the specific flow for the MEP.
The index is never reused for other flow sessions on the
same MEP while this session is active. The index value
keeps increasing until it wraps to 0. This value can also be
used in the flow-identifier TLV <a href="./rfc7455">RFC 7455</a>."
REFERENCE "<a href="./rfc7455">RFC 7455</a>"
::= { trillOamMepFlowCfgEntry 1 }
trillOamMepFlowCfgFlowEntropy OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (96))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is 96 bytes of Flow Entropy as described in
TRILL OAM, <a href="./rfc7455">RFC 7455</a>."
REFERENCE "<a href="./rfc7455#section-3">RFC 7455, Section 3</a>"
::= { trillOamMepFlowCfgEntry 2 }
trillOamMepFlowCfgDestRName OBJECT-TYPE
SYNTAX Unsigned32 (0..65471)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Target Destination RBridge Nickname field, as
defined in <a href="./rfc6325#section-3.7">RFC 6325, Section 3.7</a>, to be transmitted."
REFERENCE "<a href="./rfc7455#section-3">RFC 7455, Section 3</a>, and <a href="./rfc6325#section-3.7">RFC 6325, Section 3.7</a>"
::= { trillOamMepFlowCfgEntry 3 }
<span class="grey">Kumar, et al. Standards Track [Page 22]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-23" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMepFlowCfgFlowHC OBJECT-TYPE
SYNTAX Unsigned32 (1..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Hop Count field to be transmitted."
REFERENCE "<a href="./rfc7455#section-3">RFC 7455, Section 3</a>, and <a href="./rfc6325#section-3.6">RFC 6325, Section 3.6</a>"
::= { trillOamMepFlowCfgEntry 4 }
trillOamMepFlowCfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row cannot be changed if the row
is active. All columns MUST have a valid value before a row
can be activated."
::= { trillOamMepFlowCfgEntry 5 }
-- ******************************************************************
-- TRILL OAM Path Trace Reply Table
-- ******************************************************************
trillOamPtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrillOamPtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Path Trace Reply objects and
operations for the TRILL OAM facilities as described
in <a href="./rfc7455">RFC 7455</a>.
Each row in the table represents a Path Trace Reply Entry for
the defined MEP and Transaction. This table uses four
indices. The first three indices are the indices of the
Maintenance Domain,
MANET, and MEP tables. The fourth index is the specific
Transaction Identifier on the selected MEP.
Some writable objects in this table are only applicable in
certain cases (as described under each object),
and attempts to
write values for them in other cases will be ignored."
REFERENCE "<a href="./rfc7455">RFC 7455</a>"
::= { trillOamMep 3 }
<span class="grey">Kumar, et al. Standards Track [Page 23]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-24" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamPtrEntry OBJECT-TYPE
SYNTAX TrillOamPtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row of trillOamPtrTable."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
trillOamMepPtrTransactionId
}
::= { trillOamPtrTable 1 }
TrillOamPtrEntry ::= SEQUENCE {
trillOamMepPtrTransactionId Unsigned32,
trillOamMepPtrHC Unsigned32,
trillOamMepPtrFlag Unsigned32,
trillOamMepPtrErrorCode Unsigned32,
trillOamMepPtrTerminalMep TruthValue,
trillOamMepPtrLastEgressId Unsigned32,
trillOamMepPtrIngress Dot1agCfmIngressActionFieldValue,
trillOamMepPtrIngressMac MacAddress,
trillOamMepPtrIngressPortIdSubtype LldpPortIdSubtype,
trillOamMepPtrIngressPortId LldpPortId,
trillOamMepPtrEgress Dot1agCfmEgressActionFieldValue,
trillOamMepPtrEgressMac MacAddress,
trillOamMepPtrEgressPortIdSubtype LldpPortIdSubtype,
trillOamMepPtrEgressPortId LldpPortId,
trillOamMepPtrChassisIdSubtype LldpChassisIdSubtype,
trillOamMepPtrChassisId LldpChassisId,
trillOamMepPtrOrganizationSpecificTlv OCTET STRING,
trillOamMepPtrNextHopNicknames OCTET STRING
}
trillOamMepPtrTransactionId OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sequence Number / Transaction Identifier returned by a
previous transmit path trace message command,
indicating which PTM's response is going to be returned."
REFERENCE "<a href="./rfc7455#section-10">RFC 7455, Section 10</a>"
::= { trillOamPtrEntry 1 }
<span class="grey">Kumar, et al. Standards Track [Page 24]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-25" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMepPtrHC OBJECT-TYPE
SYNTAX Unsigned32 (1..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hop Count field value for a returned PTR."
REFERENCE "<a href="./rfc7455">RFC 7455</a>"
::= { trillOamPtrEntry 2 }
trillOamMepPtrFlag OBJECT-TYPE
SYNTAX Unsigned32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FCOI (TRILL OAM Message TLV) field value for a
returned PTR."
REFERENCE "<a href="./rfc7455#section-8.4.3">RFC 7455, Section 8.4.3</a>"
::= { trillOamPtrEntry 3 }
trillOamMepPtrErrorCode OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Return Code and Return Sub-code value for a returned PTR."
REFERENCE "<a href="./rfc7455#section-8.4.3">RFC 7455, Section 8.4.3</a>"
::= { trillOamPtrEntry 4 }
trillOamMepPtrTerminalMep OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A boolean value stating whether the forwarded PTM reached a
MEP enclosing its MA, as returned in the Terminal MEP flag of
the Flags field."
REFERENCE "<a href="./rfc7455">RFC 7455</a>"
::= { trillOamPtrEntry 5 }
trillOamMepPtrLastEgressId OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Integer field holding the Last Egress Identifier returned
in the PTR Upstream RBridge Nickname TLV of the PTR.
The Last Egress Identifier identifies the Upstream Nickname."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
<span class="grey">Kumar, et al. Standards Track [Page 25]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-26" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
::= { trillOamPtrEntry 6 }
trillOamMepPtrIngress OBJECT-TYPE
SYNTAX Dot1agCfmIngressActionFieldValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value returned in the Ingress Action field of the PTR.
The value ingNoTlv(0) indicates that no Reply Ingress TLV was
returned in the PTM."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 7 }
trillOamMepPtrIngressMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address returned in the ingress MAC address field."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 8 }
trillOamMepPtrIngressPortIdSubtype OBJECT-TYPE
SYNTAX LldpPortIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ingress Port ID. The format of this object is determined by
the value of the trillOamMepPtrIngressPortIdSubtype object."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 9 }
trillOamMepPtrIngressPortId OBJECT-TYPE
SYNTAX LldpPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ingress Port ID. The format of this object is determined by
the value of the trillOamMepPtrIngressPortId object."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 10 }
trillOamMepPtrEgress OBJECT-TYPE
SYNTAX Dot1agCfmEgressActionFieldValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value returned in the Egress Action field of the PTR.
<span class="grey">Kumar, et al. Standards Track [Page 26]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-27" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
The value ingNoTlv(0) indicates that no Reply Egress TLV was
returned in the PTM."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 11 }
trillOamMepPtrEgressMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address returned in the egress MAC address field."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 12 }
trillOamMepPtrEgressPortIdSubtype OBJECT-TYPE
SYNTAX LldpPortIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress Port ID. The format of this object is determined by
the value of the trillOamMepPtrEgressPortIdSubtype object."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 13 }
trillOamMepPtrEgressPortId OBJECT-TYPE
SYNTAX LldpPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress Port ID. The format of this object is determined by
the value of the trillOamMepPtrEgressPortId object."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 14 }
trillOamMepPtrChassisIdSubtype OBJECT-TYPE
SYNTAX LldpChassisIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the format of the Chassis ID returned
in the Sender ID TLV of the PTR, if any. This value is
meaningless if the trillOamMepPtrChassisId
has a length of 0."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 15 }
<span class="grey">Kumar, et al. Standards Track [Page 27]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-28" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMepPtrChassisId OBJECT-TYPE
SYNTAX LldpChassisId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Chassis ID returned in the Sender ID TLV of the PTR, if
any. The format of this object is determined by the
value of the trillOamMepPtrChassisIdSubtype object."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 16 }
trillOamMepPtrOrganizationSpecificTlv OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0 | 4..1500))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All organization-specific TLVs returned in the PTR, if
any. Includes all octets including and following the TLV
Length field of each TLV, concatenated together."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 17 }
trillOamMepPtrNextHopNicknames OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0 | 4..1500))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Next hop RBridge List TLV returned in the PTR, if
any. Includes all octets including and following the TLV
Length field of each TLV, concatenated together."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamPtrEntry 18 }
-- ******************************************************************
-- TRILL OAM Multi-destination Reply Table
-- ******************************************************************
trillOamMtvrTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrillOamMtvrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Multi-destination Reply objects and
operations for the TRILL OAM facilities described in
<a href="./rfc7455">RFC 7455</a>.
Each row in the table represents a Multi-destination Reply
Entry for the defined MEP and Transaction. This table uses
<span class="grey">Kumar, et al. Standards Track [Page 28]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-29" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
five indices. The first three indices are the indices of the
Maintenance Domain, MANET, and MEP tables. The fourth index
is the specific Transaction Identifier on the selected MEP.
The fifth index is the receive order of Multi-destination
replies.
Some writable objects in this table are only applicable in
certain cases (as described under each object), and attempts
to write values for them in other cases will be ignored."
REFERENCE "<a href="./rfc7455">RFC 7455</a>"
::= { trillOamMep 4 }
trillOamMtvrEntry OBJECT-TYPE
SYNTAX TrillOamMtvrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row of trillOamMtvrTable."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
trillOamMepPtrTransactionId,
trillOamMepMtvrReceiveOrder
}
::= { trillOamMtvrTable 1 }
TrillOamMtvrEntry ::= SEQUENCE {
trillOamMepMtvrTransactionId Unsigned32,
trillOamMepMtvrReceiveOrder Unsigned32,
trillOamMepMtvrFlag Unsigned32,
trillOamMepMtvrErrorCode Unsigned32,
trillOamMepMtvrLastEgressId Unsigned32,
trillOamMepMtvrIngress Dot1agCfmIngressActionFieldValue,
trillOamMepMtvrIngressMac MacAddress,
trillOamMepMtvrIngressPortIdSubtype LldpPortIdSubtype,
trillOamMepMtvrIngressPortId LldpPortId,
trillOamMepMtvrEgress Dot1agCfmEgressActionFieldValue,
trillOamMepMtvrEgressMac MacAddress,
trillOamMepMtvrEgressPortIdSubtype LldpPortIdSubtype,
trillOamMepMtvrEgressPortId LldpPortId,
trillOamMepMtvrChassisIdSubtype LldpChassisIdSubtype,
trillOamMepMtvrChassisId LldpChassisId,
trillOamMepMtvrOrganizationSpecificTlv OCTET STRING,
trillOamMepMtvrNextHopNicknames OCTET STRING,
trillOamMepMtvrReceiverAvailability TruthValue,
trillOamMepMtvrReceiverCount TruthValue
}
<span class="grey">Kumar, et al. Standards Track [Page 29]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-30" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMepMtvrTransactionId OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sequence Number / Transaction Identifier returned by a
previously transmitted Multi-destination message command
indicating which MTVM's response is going to be returned."
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
::= { trillOamMtvrEntry 1 }
trillOamMepMtvrReceiveOrder OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index to distinguish among multiple MTVRs with same MTVR
Transaction Identifier field value.
trillOamMepMtvrReceiveOrder is assigned sequentially from 1,
in the order that the Multi-destination Tree Initiator
received the MTVRs."
REFERENCE "<a href="./rfc7455#section-11">RFC 7455, Section 11</a>"
::= { trillOamMtvrEntry 2 }
trillOamMepMtvrFlag OBJECT-TYPE
SYNTAX Unsigned32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FCOI (TRILL OAM Message TLV) field value for a
returned MTVR."
REFERENCE "<a href="./rfc7455#section-8.4.2">RFC 7455, Section 8.4.2</a>"
::= { trillOamMtvrEntry 3 }
trillOamMepMtvrErrorCode OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Return Code and Return Sub-code value for a returned MTVR."
REFERENCE "<a href="./rfc7455#section-8.4.2">RFC 7455, Section 8.4.2</a>"
::= { trillOamMtvrEntry 4 }
trillOamMepMtvrLastEgressId OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
<span class="grey">Kumar, et al. Standards Track [Page 30]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-31" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
DESCRIPTION
"An Integer field holding the Last Egress Identifier returned
in the MTVR Upstream RBridge Nickname TLV of the MTVR. The
Last Egress Identifier identifies the Upstream Nickname."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamMtvrEntry 5 }
trillOamMepMtvrIngress OBJECT-TYPE
SYNTAX Dot1agCfmIngressActionFieldValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value returned in the Ingress Action field of
the MTVR. The value ingNoTlv(0) indicates that no
Reply Ingress TLV was returned in the MTVM."
REFERENCE "<a href="./rfc7455#section-11.2.3">RFC 7455, Section 11.2.3</a>"
::= { trillOamMtvrEntry 6 }
trillOamMepMtvrIngressMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address returned in the ingress MAC address field."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamMtvrEntry 7 }
trillOamMepMtvrIngressPortIdSubtype OBJECT-TYPE
SYNTAX LldpPortIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ingress Port ID. The format of this object is
determined by the value of the
trillOamMepMtvrIngressPortIdSubtype object."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamMtvrEntry 8 }
trillOamMepMtvrIngressPortId OBJECT-TYPE
SYNTAX LldpPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ingress Port ID. The format of this object is determined by
the value of the trillOamMepMtvrIngressPortId object."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamMtvrEntry 9 }
<span class="grey">Kumar, et al. Standards Track [Page 31]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-32" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMepMtvrEgress OBJECT-TYPE
SYNTAX Dot1agCfmEgressActionFieldValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value returned in the Egress Action field of the MTVR.
The value ingNoTlv(0) indicates that no Reply Egress TLV was
returned in the MTVR."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamMtvrEntry 10 }
trillOamMepMtvrEgressMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address returned in the egress MAC address field."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamMtvrEntry 11 }
trillOamMepMtvrEgressPortIdSubtype OBJECT-TYPE
SYNTAX LldpPortIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress Port ID. The format of this object is determined by
the value of the trillOamMepMtvrEgressPortIdSubtype object."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamMtvrEntry 12 }
trillOamMepMtvrEgressPortId OBJECT-TYPE
SYNTAX LldpPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress Port ID. The format of this object is determined by
the value of the trillOamMepMtvrEgressPortId object."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamMtvrEntry 13 }
trillOamMepMtvrChassisIdSubtype OBJECT-TYPE
SYNTAX LldpChassisIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the format of the Chassis ID returned
in the Sender ID TLV of the MTVR, if any. This value is
meaningless if the trillOamMepMtvrChassisId has a
<span class="grey">Kumar, et al. Standards Track [Page 32]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-33" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
length of 0."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamMtvrEntry 14 }
trillOamMepMtvrChassisId OBJECT-TYPE
SYNTAX LldpChassisId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Chassis ID returned in the Sender ID TLV of the MTVR, if
any. The format of this object is determined by the
value of the trillOamMepMtvrChassisIdSubtype object."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamMtvrEntry 15 }
trillOamMepMtvrOrganizationSpecificTlv OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0 | 4..1500))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All organization-specific TLVs returned in the MTVR, if
any. Includes all octets including and following the TLV
Length field of each TLV, concatenated together."
REFERENCE "<a href="./rfc7455#section-8.4.1">RFC 7455, Section 8.4.1</a>"
::= { trillOamMtvrEntry 16 }
trillOamMepMtvrNextHopNicknames OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0 | 4..1500))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Next hop RBridge List TLV returned in the PTR, if
any. Includes all octets including and following the TLV
Length field of each TLV, concatenated together."
REFERENCE "<a href="./rfc7455#section-8.4.3">RFC 7455, Section 8.4.3</a>"
::= { trillOamMtvrEntry 17 }
trillOamMepMtvrReceiverAvailability OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value of true indicates that the MTVR response contained
Multicast receiver availability TLV."
REFERENCE "<a href="./rfc7455#section-8.4.10">RFC 7455, Section 8.4.10</a>"
::= { trillOamMtvrEntry 18 }
<span class="grey">Kumar, et al. Standards Track [Page 33]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-34" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMepMtvrReceiverCount OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of multicast receivers available on
the responding RBridge on the VLAN specified by the
diagnostic VLAN."
REFERENCE "<a href="./rfc7455#section-8.4.10">RFC 7455, Section 8.4.10</a>"
::= { trillOamMtvrEntry 19 }
-- *****************************************************************
-- TRILL OAM MEP Database Table
-- *****************************************************************
trillOamMepDbTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrillOamMepDbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of the dot1agCfmMepDbTable
and rows are automatically added to or deleted from
this table based upon row creation and destruction of the
dot1agCfmMepDbTable."
REFERENCE
"<a href="./rfc7455">RFC 7455</a>"
::= { trillOamMep 5 }
trillOamMepDbEntry OBJECT-TYPE
SYNTAX TrillOamMepDbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row of trillOamMepDbTable."
AUGMENTS {
dot1agCfmMepDbEntry
}
::= { trillOamMepDbTable 1 }
TrillOamMepDbEntry ::= SEQUENCE {
trillOamMepDbFlowIndex Unsigned32,
trillOamMepDbFlowEntropy OCTET STRING,
trillOamMepDbFlowState Dot1agCfmRemoteMepState,
trillOamMepDbFlowFailedOkTime TimeStamp,
trillOamMepDbRBridgeName Unsigned32,
trillOamMepDbLastGoodSeqNum Counter32
}
<span class="grey">Kumar, et al. Standards Track [Page 34]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-35" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMepDbFlowIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the flow. If the Flow Identifier TLV
is received, then the index received can also be used."
REFERENCE "<a href="./rfc7455">RFC 7455</a>"
::= {trillOamMepDbEntry 1 }
trillOamMepDbFlowEntropy OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (96))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"96 byte Flow Entropy."
REFERENCE "<a href="./rfc7455#section-3">RFC 7455, Section 3</a>"
::= {trillOamMepDbEntry 2 }
trillOamMepDbFlowState OBJECT-TYPE
SYNTAX Dot1agCfmRemoteMepState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state of the remote MEP (flow-based)
IFF State machines. State Machine is running now per
flow."
REFERENCE "<a href="./rfc7455">RFC 7455</a>"
::= {trillOamMepDbEntry 3 }
trillOamMepDbFlowFailedOkTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Time (sysUpTime) at which the Remote MEP flow state
machine last entered either the RMEP_FAILED or RMEP_OK
state."
REFERENCE "<a href="./rfc7455">RFC 7455</a>"
::= {trillOamMepDbEntry 4 }
trillOamMepDbRBridgeName OBJECT-TYPE
SYNTAX Unsigned32(0..65471)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote MEP RBridge Nickname."
REFERENCE "<a href="./rfc7455">RFC 7455</a> and <a href="./rfc6325#section-3">RFC 6325, Section 3</a>"
<span class="grey">Kumar, et al. Standards Track [Page 35]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-36" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
::= {trillOamMepDbEntry 5 }
trillOamMepDbLastGoodSeqNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last Sequence Number received."
REFERENCE "<a href="./rfc7455#section-13.1">RFC 7455, Section 13.1</a>"
::= {trillOamMepDbEntry 6}
-- ******************************************************************
-- TRILL OAM MIB NOTIFICATIONS (TRAPS)
-- This notification is sent to management entity whenever a
-- MEP loses/restores
-- contact with its peer flow MEPs
-- ******************************************************************
trillOamFaultAlarm NOTIFICATION-TYPE
OBJECTS { trillOamMepDbFlowState }
STATUS current
DESCRIPTION
"A MEP flow has a persistent defect condition.
A notification (fault alarm) is sent to the management
entity with the OID of the flow that has detected the fault.
The management entity receiving the notification can identify
the system from the network source address of the
notification and can identify the flow reporting the defect
by the indices in the OID of the trillOamMepFlowIndex and
trillOamFlowDefect variable in the notification:
dot1agCfmMdIndex - Also the index of the MEP's
Maintenance Domain table entry
(dot1agCfmMdTable).
dot1agCfmMaIndex - Also an index (with the MD table index)
of the MEP's Maintenance Association
network table entry
(dot1agCfmMaNetTable) and (with the MD
table index and component ID) of the
MEP's MA component table entry
(dot1agCfmMaCompTable).
dot1agCfmMepIdentifier - MEP Identifier and final index
into the MEP table (dot1agCfmMepTable).
trillOamMepFlowCfgIndex - Index identifies
indicates the specific flow for
the MEP"
REFERENCE "<a href="./rfc7455">RFC 7455</a>"
::= { trillOamNotifications 1 }
<span class="grey">Kumar, et al. Standards Track [Page 36]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-37" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
-- ******************************************************************
-- TRILL OAM MIB Module - Conformance Information
-- ******************************************************************
trillOamMibCompliances OBJECT IDENTIFIER
::= { trillOamMibConformance 1 }
trillOamMibGroups OBJECT IDENTIFIER
::= { trillOamMibConformance 2 }
-- ******************************************************************
-- TRILL OAM MIB Units of Conformance
-- ******************************************************************
trillOamMepMandatoryGroup OBJECT-GROUP
OBJECTS {
trillOamMepRName,
trillOamMepNextPtmTId,
trillOamMepNextMtvmTId,
trillOamMepPtrIn,
trillOamMepPtrInOutofOrder,
trillOamMepPtrOut,
trillOamMepMtvrIn,
trillOamMepMtvrInOutofOrder,
trillOamMepMtvrOut,
trillOamMepTxLbmDestRName,
trillOamMepTxLbmHC,
trillOamMepTxLbmReplyModeOob,
trillOamMepTransmitLbmReplyIp,
trillOamMepTxLbmFlowEntropy,
trillOamMepTxPtmDestRName,
trillOamMepTxPtmHC,
trillOamMepTxPtmReplyModeOob,
trillOamMepTransmitPtmReplyIp,
trillOamMepTxPtmFlowEntropy,
trillOamMepTxPtmStatus,
trillOamMepTxPtmResultOK,
trillOamMepTxPtmMessages,
trillOamMepTxPtmSeqNumber,
trillOamMepTxMtvmTree,
trillOamMepTxMtvmHC,
trillOamMepTxMtvmReplyModeOob,
trillOamMepTransmitMtvmReplyIp,
trillOamMepTxMtvmFlowEntropy,
trillOamMepTxMtvmStatus,
trillOamMepTxMtvmResultOK,
trillOamMepTxMtvmMessages,
trillOamMepTxMtvmSeqNumber,
<span class="grey">Kumar, et al. Standards Track [Page 37]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-38" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMepTxMtvmScopeList,
trillOamMepDiscontinuityTime
}
STATUS current
DESCRIPTION
"Mandatory objects for the TRILL OAM MEP group."
::= { trillOamMibGroups 1 }
trillOamMepFlowCfgTableGroup OBJECT-GROUP
OBJECTS {
trillOamMepFlowCfgFlowEntropy,
trillOamMepFlowCfgDestRName,
trillOamMepFlowCfgFlowHC,
trillOamMepFlowCfgRowStatus
}
STATUS current
DESCRIPTION
"TRILL OAM MEP Flow Configuration objects group."
::= { trillOamMibGroups 2 }
trillOamPtrTableGroup OBJECT-GROUP
OBJECTS {
trillOamMepPtrHC,
trillOamMepPtrFlag,
trillOamMepPtrErrorCode,
trillOamMepPtrTerminalMep,
trillOamMepPtrLastEgressId,
trillOamMepPtrIngress,
trillOamMepPtrIngressMac,
trillOamMepPtrIngressPortIdSubtype,
trillOamMepPtrIngressPortId,
trillOamMepPtrEgress,
trillOamMepPtrEgressMac,
trillOamMepPtrEgressPortIdSubtype,
trillOamMepPtrEgressPortId,
trillOamMepPtrChassisIdSubtype,
trillOamMepPtrChassisId,
trillOamMepPtrOrganizationSpecificTlv,
trillOamMepPtrNextHopNicknames
}
STATUS current
DESCRIPTION
"TRILL OAM MEP PTR objects group."
::= { trillOamMibGroups 3 }
<span class="grey">Kumar, et al. Standards Track [Page 38]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-39" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
trillOamMtvrTableGroup OBJECT-GROUP
OBJECTS {
trillOamMepMtvrFlag,
trillOamMepMtvrErrorCode,
trillOamMepMtvrLastEgressId,
trillOamMepMtvrIngress,
trillOamMepMtvrIngressMac,
trillOamMepMtvrIngressPortIdSubtype,
trillOamMepMtvrIngressPortId,
trillOamMepMtvrEgress,
trillOamMepMtvrEgressMac,
trillOamMepMtvrEgressPortIdSubtype,
trillOamMepMtvrEgressPortId,
trillOamMepMtvrChassisIdSubtype,
trillOamMepMtvrChassisId,
trillOamMepMtvrOrganizationSpecificTlv,
trillOamMepMtvrNextHopNicknames,
trillOamMepMtvrReceiverAvailability,
trillOamMepMtvrReceiverCount
}
STATUS current
DESCRIPTION
"TRILL OAM MEP MTVR objects group."
::= { trillOamMibGroups 4 }
trillOamMepDbGroup OBJECT-GROUP
OBJECTS {
trillOamMepDbFlowIndex,
trillOamMepDbFlowEntropy,
trillOamMepDbFlowState,
trillOamMepDbFlowFailedOkTime,
trillOamMepDbRBridgeName,
trillOamMepDbLastGoodSeqNum
}
STATUS current
DESCRIPTION
"TRILL OAM MEP DB objects group."
::= { trillOamMibGroups 5 }
trillOamNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { trillOamFaultAlarm }
STATUS current
DESCRIPTION
"A collection of objects describing notifications(traps)."
::= { trillOamMibGroups 6 }
<span class="grey">Kumar, et al. Standards Track [Page 39]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-40" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
-- ******************************************************************
-- TRILL OAM MIB Module Compliance Statements
-- ******************************************************************
trillOamMibCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the TRILL OAM MIB."
MODULE -- this module
MANDATORY-GROUPS {
trillOamMepMandatoryGroup,
trillOamMepFlowCfgTableGroup,
trillOamPtrTableGroup,
trillOamMtvrTableGroup,
trillOamMepDbGroup,
trillOamNotificationGroup
}
::= { trillOamMibCompliances 1 }
-- Compliance requirement for read-only implementation.
trillOamMibReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance requirement for implementations that only
provide read-only support for TRILL-OAM-MIB.
Such devices can be monitored but cannot be configured
using this MIB module."
MODULE -- this module
MANDATORY-GROUPS {
trillOamMepMandatoryGroup,
trillOamMepFlowCfgTableGroup,
trillOamPtrTableGroup,
trillOamMtvrTableGroup,
trillOamMepDbGroup,
trillOamNotificationGroup
}
-- trillOamMepTable
OBJECT trillOamMepTxLbmDestRName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxLbmHC
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
<span class="grey">Kumar, et al. Standards Track [Page 40]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-41" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
OBJECT trillOamMepTxLbmReplyModeOob
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTransmitLbmReplyIp
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxLbmFlowEntropy
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxPtmDestRName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxPtmHC
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxPtmReplyModeOob
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTransmitPtmReplyIp
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxPtmFlowEntropy
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxPtmStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
<span class="grey">Kumar, et al. Standards Track [Page 41]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-42" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
OBJECT trillOamMepTxPtmResultOK
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxPtmMessages
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxPtmSeqNumber
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxMtvmTree
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxMtvmHC
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxMtvmReplyModeOob
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTransmitMtvmReplyIp
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxMtvmFlowEntropy
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxMtvmStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
<span class="grey">Kumar, et al. Standards Track [Page 42]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-43" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
OBJECT trillOamMepTxMtvmResultOK
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxMtvmMessages
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxMtvmSeqNumber
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepTxMtvmScopeList
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
-- trillOamMepFlowCfgTable
OBJECT trillOamMepFlowCfgFlowEntropy
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepFlowCfgDestRName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepFlowCfgFlowHC
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT trillOamMepFlowCfgRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { trillOamMibCompliances 2 }
END
<span class="grey">Kumar, et al. Standards Track [Page 43]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-44" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
<span class="h2"><a class="selflink" id="section-8" href="#section-8">8</a>. Security Considerations</span>
This MIB relates to a system that will provide network connectivity
and packet-forwarding services. As such, improper manipulation of
the objects represented by this MIB may result in denial of service
to a large number of end users.
There are a number of management objects defined in this MIB module
with a MAX-ACCESS clause of read-create. Such objects may be
considered sensitive or vulnerable in some network environments. The
support for SET operations in a non-secure environment without proper
protection opens devices to attack. There are the tables and objects
and their sensitivity/vulnerability:
The following table and objects in the TRILL OAM MIB can be
manipulated to interfere with the operation of RBridges by causing
CPU use spikes:
o trillOamMepTransmitLbmReplyIp allows the reply from a Loopback
message to be transmitted to an IP address in the TLV, thus
allowing replies to be sent to any system to cause denial of
service.
o trillOamMepTransmitPtmReplyIp allows the reply from a Path Trace
message to be transmitted to an IP address in the TLV, thus
allowing replies to be sent to any system to cause denial of
service.
o trillOamMepTxPtmMessages allows the generation of PTMs and can be
used to generate lots of CPU-driven traffic.
o trillOamMepTransmitMtvmReplyIp allows a from reply from an MTVM to
be transmitted to an IP address in the TLV, thus allowing replies
to be sent to any system to cause denial of service.
o trillOamMepTxMtvmMessages allows the generation of MTVMs and can
be used to generate lots of CPU-driven traffic.
The following objects in the TRILL OAM MIB are read-create and can be
manipulated to interfere with the OAM operations of RBridges. If the
number of OAM frames generated in the network is high, this can cause
a CPU spike on destination RBridges if control-plane policing is not
properly implemented or configured on destination RBridges.
o trillOamMepTxLbmHC is used to set the Maximum Hop Count for the
LBM. As OAM frames don't leak out of the TRILL network, it has no
side effects.
<span class="grey">Kumar, et al. Standards Track [Page 44]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-45" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
o trillOamMepTxLbmReplyModeOob is used to indicate whether the reply
is in or out of band. This object's vulnerability is covered as
part of trillOamMepTransmitLbmReplyIp.
o trillOamMepTxLbmFlowEntropy is used to indicate the customer flow
and find the exact path in the network. The creation of valid
flows is its intended purpose. If invalid flows are created on
vulnerable system, they will be dropped in forwarding.
o trillOamMepTxLbmDestRName is read-create, but it's not vulnerable
as invalid-name routes won't be present and will be rejected by
the OAM application as part of normal processing.
o trillOamMepTxPtmHC is used to set the Maximum Hop Count for the
PTM. As OAM frames don't leak out of the TRILL network, it has no
side effect.
o trillOamMepTxPtmReplyModeOob is used to indicate whether the reply
is in or out of band. This object's vulnerability is covered as
part of trillOamMepTransmitPtmReplyIp.
o trillOamMepTxPtmFlowEntropy is used to indicate the customer flow
and find the exact path in the network. Creation of valid flows
is its intended purpose. If invalid flows are created on
vulnerable systems, they will be dropped in forwarding.
o trillOamMepTxPtmDestRName is read-create, but it's not vulnerable
as invalid-name routes won't be present and will be rejected by
the OAM application as part of normal processing.
o trillOamMepTxPtmStatus is required for normal PTM operation.
o trillOamMepTxPtmResultOK is required for normal PTM operation.
o trillOamMepTxPtmSeqNumber is required for normal PTM operation.
o trillOamMepTxPtmMessages is required for normal PTM operation.
o trillOamMepTxMtvmTree is required for normal MTVM operation.
o trillOamMepTxMtvmHC is used to set the Maximum Hop Count for the
MTVM. As OAM frames don't leak out of the TRILL network, it has
no side effect
o trillOamMepTxMtvmReplyModeOob is used to indicate whether the
reply is in or out of band. This object's vulnerability is
covered as part of trillOamMepTransmitMtmReplyIp
<span class="grey">Kumar, et al. Standards Track [Page 45]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-46" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
o trillOamMepTxMtvmFlowEntropy is used to indicate the customer flow
and find the exact path in the network. Creation of valid flows
is its intended purpose. If invalid flows are created on
vulnerable systems, they will be dropped in forwarding.
o trillOamMepTxMtvmStatus is required for normal MTVM operation.
o trillOamMepTxMtvmResultOK, trillOamMepTxMtvmMessages,
trillOamMepTxMtvmSeqNumber, and trillOamMepTxMtvmScopeList are
required for normal MTVM operation.
trillOamMepTransmitLbmReplyIp, trillOamMepTransmitPtmReplyIp, and
trillOamMepTransmitMtvmReplyIp allow setting of the IP address to
which reports are sent; thus, it can be used for denial of service
for that IP.
Some of the readable objects in this MIB module (i.e., objects with a
MAX-ACCESS other than not-accessible) may be considered sensitive or
vulnerable in some network environments. It is thus important to
control even GET and/or NOTIFY access to these objects and possibly
to even encrypt the values of these objects when sending them over
the network via SNMP. For example, Path Trace messages expose the
unicast topology of the network and Multi-destination Tree
Verification Messages expose the multicast tree topology of the
network. This information should not be available to all users of
the network.
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPsec),
there is no control as to who on the secure network is allowed to
access and GET/SET (read/change/create/delete) the objects in this
MIB module.
Implementation should provide the security features described by the
SNMPv3 framework (see [<a href="./rfc3410" title=""Introduction and Applicability Statements for Internet- Standard Management Framework"">RFC3410</a>]), and implementations claiming
compliance to the SNMPv3 standard MUST include full support for
authentication and privacy via the User-based Security Model (USM)
[<a href="./rfc3414" title=""User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)"">RFC3414</a>] with the AES cipher algorithm [<a href="./rfc3826" title=""The Advanced Encryption Standard (AES) Cipher Algorithm in the SNMP User-based Security Model"">RFC3826</a>]. Implementations
MAY also provide support for the Transport Security Model (TSM)
[<a href="./rfc5591" title=""Transport Security Model for the Simple Network Management Protocol (SNMP)"">RFC5591</a>] in combination with a secure transport such as SSH
[<a href="./rfc5592" title=""Secure Shell Transport Model for the Simple Network Management Protocol (SNMP)"">RFC5592</a>] or TLS/DTLS [<a href="./rfc6353" title=""Transport Layer Security (TLS) Transport Model for the Simple Network Management Protocol (SNMP)"">RFC6353</a>].
Further, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of this MIB module is properly configured to give only those
<span class="grey">Kumar, et al. Standards Track [Page 46]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-47" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
principals (users) that have legitimate rights to indeed GET or SET
(change/create/delete) them.
<span class="h2"><a class="selflink" id="section-9" href="#section-9">9</a>. IANA Considerations</span>
The MIB module in this document uses the following IANA-assigned
OBJECT IDENTIFIER value recorded in the SMI Numbers registry:
Descriptor OBJECT IDENTIFIER value
----------------------------------------
trillOamMIB { mib-2 238 }
<span class="h2"><a class="selflink" id="section-10" href="#section-10">10</a>. References</span>
<span class="h3"><a class="selflink" id="section-10.1" href="#section-10.1">10.1</a>. Normative References</span>
[<a id="ref-802.1Q">802.1Q</a>] IEEE, "IEEE Standard for Local and metropolitan area
networks -- Media Access Control (MAC) Bridges and
Virtual Bridge Local Area Networks", IEEE Std
802.1Q-2011, DOI 10.1109/IEEESTD.2011.6009146.
[<a id="ref-IEEE8021-CFM-MIB">IEEE8021-CFM-MIB</a>]
IEEE, "Connectivity Fault Management module for managing
IEEE 802.1ag", IEEE 802.1ag, October 2008,
<<a href="http://www.ieee802.org/1/files/public/MIBs/IEEE8021-CFM-MIB-200810150000Z.txt">http://www.ieee802.org/1/files/public/MIBs/IEEE8021-CFM-</a>
<a href="http://www.ieee802.org/1/files/public/MIBs/IEEE8021-CFM-MIB-200810150000Z.txt">MIB-200810150000Z.txt</a>>.
[<a id="ref-LLDP-MIB">LLDP-MIB</a>] IEEE, "Management Information Base module for LLDP
configuration, statistics, local system data and remote
systems data components", IEEE 802.1AB, May 2005,
<<a href="http://www.ieee802.org/1/files/public/MIBs/LLDP-MIB-200505060000Z.txt">http://www.ieee802.org/1/files/public/MIBs/</a>
<a href="http://www.ieee802.org/1/files/public/MIBs/LLDP-MIB-200505060000Z.txt">LLDP-MIB-200505060000Z.txt</a>>.
[<a id="ref-RFC2119">RFC2119</a>] Bradner, S., "Key words for use in RFCs to Indicate
Requirement
Levels", <a href="https://www.rfc-editor.org/bcp/bcp14">BCP 14</a>, <a href="./rfc2119">RFC 2119</a>, DOI 10.17487/RFC2119, March
1997, <<a href="http://www.rfc-editor.org/info/rfc2119">http://www.rfc-editor.org/info/rfc2119</a>>.
[<a id="ref-RFC2578">RFC2578</a>] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Structure of Management Information
Version 2 (SMIv2)", STD 58, <a href="./rfc2578">RFC 2578</a>,
DOI 10.17487/RFC2578, April 1999,
<<a href="http://www.rfc-editor.org/info/rfc2578">http://www.rfc-editor.org/info/rfc2578</a>>.
[<a id="ref-RFC2579">RFC2579</a>] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Textual Conventions for SMIv2", STD
58, <a href="./rfc2579">RFC 2579</a>, DOI 10.17487/RFC2579, April 1999,
<<a href="http://www.rfc-editor.org/info/rfc2579">http://www.rfc-editor.org/info/rfc2579</a>>.
<span class="grey">Kumar, et al. Standards Track [Page 47]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-48" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
[<a id="ref-RFC2580">RFC2580</a>] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Conformance Statements for SMIv2",
STD 58, <a href="./rfc2580">RFC 2580</a>, DOI 10.17487/RFC2580, April 1999,
<<a href="http://www.rfc-editor.org/info/rfc2580">http://www.rfc-editor.org/info/rfc2580</a>>.
[<a id="ref-RFC3414">RFC3414</a>] Blumenthal, U. and B. Wijnen, "User-based Security Model
(USM) for version 3 of the Simple Network Management
Protocol (SNMPv3)", STD 62, <a href="./rfc3414">RFC 3414</a>,
DOI 10.17487/RFC3414, December 2002,
<<a href="http://www.rfc-editor.org/info/rfc3414">http://www.rfc-editor.org/info/rfc3414</a>>.
[<a id="ref-RFC3826">RFC3826</a>] Blumenthal, U., Maino, F., and K. McCloghrie, "The
Advanced Encryption Standard (AES) Cipher Algorithm in
the SNMP User-based Security Model", <a href="./rfc3826">RFC 3826</a>,
DOI 10.17487/RFC3826, June 2004,
<<a href="http://www.rfc-editor.org/info/rfc3826">http://www.rfc-editor.org/info/rfc3826</a>>.
[<a id="ref-RFC5591">RFC5591</a>] Harrington, D. and W. Hardaker, "Transport Security Model
for the Simple Network Management Protocol (SNMP)",
STD 78, <a href="./rfc5591">RFC 5591</a>, DOI 10.17487/RFC5591, June 2009,
<<a href="http://www.rfc-editor.org/info/rfc5591">http://www.rfc-editor.org/info/rfc5591</a>>.
[<a id="ref-RFC5592">RFC5592</a>] Harrington, D., Salowey, J., and W. Hardaker, "Secure
Shell Transport Model for the Simple Network Management
Protocol (SNMP)", <a href="./rfc5592">RFC 5592</a>, DOI 10.17487/RFC5592, June
2009, <<a href="http://www.rfc-editor.org/info/rfc5592">http://www.rfc-editor.org/info/rfc5592</a>>.
[<a id="ref-RFC6325">RFC6325</a>] Perlman, R., Eastlake 3rd, D., Dutt, D., Gai, S., and A.
Ghanwani, "Routing Bridges (RBridges): Base Protocol
Specification", <a href="./rfc6325">RFC 6325</a>, DOI 10.17487/RFC6325, July
2011, <<a href="http://www.rfc-editor.org/info/rfc6325">http://www.rfc-editor.org/info/rfc6325</a>>.
[<a id="ref-RFC6353">RFC6353</a>] Hardaker, W., "Transport Layer Security (TLS) Transport
Model for the Simple Network Management Protocol (SNMP)",
STD 78, <a href="./rfc6353">RFC 6353</a>, DOI 10.17487/RFC6353, July 2011,
<<a href="http://www.rfc-editor.org/info/rfc6353">http://www.rfc-editor.org/info/rfc6353</a>>.
[<a id="ref-RFC7172">RFC7172</a>] Eastlake 3rd, D., Zhang, M., Agarwal, P., Perlman, R.,
and D. Dutt, "Transparent Interconnection of Lots of
Links (TRILL): Fine-Grained Labeling", <a href="./rfc7172">RFC 7172</a>,
DOI 10.17487/RFC7172, May 2014,
<<a href="http://www.rfc-editor.org/info/rfc7172">http://www.rfc-editor.org/info/rfc7172</a>>.
[<a id="ref-RFC7455">RFC7455</a>] Senevirathne, T., Finn, N., Salam, S., Kumar, D.,
Eastlake 3rd, D., Aldrin, S., and Y. Li, "Transparent
Interconnection of Lots of Links (TRILL): Fault
Management", <a href="./rfc7455">RFC 7455</a>, DOI 10.17487/RFC7455, March 2015,
<<a href="http://www.rfc-editor.org/info/rfc7455">http://www.rfc-editor.org/info/rfc7455</a>>.
<span class="grey">Kumar, et al. Standards Track [Page 48]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-49" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
<span class="h3"><a class="selflink" id="section-10.2" href="#section-10.2">10.2</a>. Informative References</span>
[<a id="ref-Q.840.1">Q.840.1</a>] ITU-T, "Requirements and analysis for NMS-EMS management
interface of Ethernet over Transport and Metro Ethernet
Network (EoT/MEN)", Recommendation Q.840.1, March 2007.
[<a id="ref-RFC3410">RFC3410</a>] Case, J., Mundy, R., Partain, D., and B. Stewart,
"Introduction and Applicability Statements for Internet-
Standard Management Framework", <a href="./rfc3410">RFC 3410</a>,
DOI 10.17487/RFC3410, December 2002,
<<a href="http://www.rfc-editor.org/info/rfc3410">http://www.rfc-editor.org/info/rfc3410</a>>.
[<a id="ref-RFC6905">RFC6905</a>] Senevirathne, T., Bond, D., Aldrin, S., Li, Y., and R.
Watve, "Requirements for Operations, Administration, and
Maintenance (OAM) in Transparent Interconnection of Lots
of Links (TRILL)", <a href="./rfc6905">RFC 6905</a>, DOI 10.17487/RFC6905, March
2013, <<a href="http://www.rfc-editor.org/info/rfc6905">http://www.rfc-editor.org/info/rfc6905</a>>.
[<a id="ref-RFC7174">RFC7174</a>] Salam, S., Senevirathne, T., Aldrin, S., and D. Eastlake
3rd, "Transparent Interconnection of Lots of Links
(TRILL) Operations, Administration, and Maintenance (OAM)
Framework", <a href="./rfc7174">RFC 7174</a>, DOI 10.17487/RFC7174, May 2014,
<<a href="http://www.rfc-editor.org/info/rfc7174">http://www.rfc-editor.org/info/rfc7174</a>>.
<span class="grey">Kumar, et al. Standards Track [Page 49]</span></pre>
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-50" ></span>
<span class="grey"><a href="./rfc7784">RFC 7784</a> TRILL OAM MIB February 2016</span>
Acknowledgments
We wish to thank members of the IETF TRILL WG and the MIB Doctors for
their comments and suggestions. Detailed comments were provided by
Sam Aldrin, Donald Eastlake, Tom Taylor, and Harrie Hazewinkel.
Authors' Addresses
Deepak Kumar
Cisco
510 McCarthy Blvd.
Milpitas, CA 95035
United States
Phone : +1 408-853-9760
Email: dekumar@cisco.com
Samer Salam
Cisco
595 Burrard St.
Suite 2123
Vancouver, BC V7X 1J1
Canada
Email: ssalam@cisco.com
Tissa Senevirathne
Consultant
Email: tsenevir@gmail.com
Kumar, et al. Standards Track [Page 50]
</pre>
|