1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409
|
.. SPDX-License-Identifier: BSD-3-Clause
Copyright(c) 2016 Cavium, Inc
ThunderX NICVF Poll Mode Driver
===============================
The ThunderX NICVF PMD (**librte_net_thunderx**) provides poll mode driver
support for the inbuilt NIC found in the **Cavium ThunderX** SoC family
as well as their virtual functions (VF) in SR-IOV context.
More information can be found at `Cavium, Inc Official Website
<http://www.cavium.com/ThunderX_ARM_Processors.html>`_.
Supported ThunderX SoCs
-----------------------
- CN88xx
- CN81xx
- CN83xx
Features
--------
Features of the ThunderX PMD are:
- Multiple queues for TX and RX
- Receive Side Scaling (RSS)
- Packet type information
- Checksum offload
- Promiscuous mode
- Multicast mode
- Port hardware statistics
- Jumbo frames
- Link state information
- Setting up link state.
- Scattered and gather for TX and RX
- VLAN stripping
- SR-IOV VF
- NUMA support
- Multi queue set support (up to 96 queues (12 queue sets)) per port
- Skip data bytes
Prerequisites
-------------
- Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
Driver compilation and testing
------------------------------
Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
for details.
Use config/arm/arm64-thunderx-linux-gcc as a meson cross-file when cross-compiling.
Linux
-----
SR-IOV: Prerequisites and sample Application Notes
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Current ThunderX NIC PF/VF kernel modules maps each physical Ethernet port
automatically to virtual function (VF) and presented them as PCIe-like SR-IOV device.
This section provides instructions to configure SR-IOV with Linux OS.
#. Verify PF devices capabilities using ``lspci``:
.. code-block:: console
lspci -vvv
Example output:
.. code-block:: console
0002:01:00.0 Ethernet controller: Cavium Networks Device a01e (rev 01)
...
Capabilities: [100 v1] Alternative Routing-ID Interpretation (ARI)
...
Capabilities: [180 v1] Single Root I/O Virtualization (SR-IOV)
...
Kernel driver in use: thunder-nic
...
.. note::
Unless ``thunder-nic`` driver is in use make sure your kernel config includes ``CONFIG_THUNDER_NIC_PF`` setting.
#. Verify VF devices capabilities and drivers using ``lspci``:
.. code-block:: console
lspci -vvv
Example output:
.. code-block:: console
0002:01:00.1 Ethernet controller: Cavium Networks Device 0011 (rev 01)
...
Capabilities: [100 v1] Alternative Routing-ID Interpretation (ARI)
...
Kernel driver in use: thunder-nicvf
...
0002:01:00.2 Ethernet controller: Cavium Networks Device 0011 (rev 01)
...
Capabilities: [100 v1] Alternative Routing-ID Interpretation (ARI)
...
Kernel driver in use: thunder-nicvf
...
.. note::
Unless ``thunder-nicvf`` driver is in use make sure your kernel config includes ``CONFIG_THUNDER_NIC_VF`` setting.
#. Pass VF device to VM context (PCIe Passthrough):
The VF devices may be passed through to the guest VM using qemu or
virt-manager or virsh etc.
Example qemu guest launch command:
.. code-block:: console
sudo qemu-system-aarch64 -name vm1 \
-machine virt,gic_version=3,accel=kvm,usb=off \
-cpu host -m 4096 \
-smp 4,sockets=1,cores=8,threads=1 \
-nographic -nodefaults \
-kernel <kernel image> \
-append "root=/dev/vda console=ttyAMA0 rw hugepagesz=512M hugepages=3" \
-device vfio-pci,host=0002:01:00.1 \
-drive file=<rootfs.ext3>,if=none,id=disk1,format=raw \
-device virtio-blk-device,scsi=off,drive=disk1,id=virtio-disk1,bootindex=1 \
-netdev tap,id=net0,ifname=tap0,script=/etc/qemu-ifup_thunder \
-device virtio-net-device,netdev=net0 \
-serial stdio \
-mem-path /dev/hugepages
#. Enable **VFIO-NOIOMMU** mode (optional):
.. code-block:: console
echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode
.. note::
**VFIO-NOIOMMU** is required only when running in VM context and should not be enabled otherwise.
#. Running testpmd:
Follow instructions available in the document
:ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
to run testpmd.
Example output:
.. code-block:: console
./<build_dir>/app/dpdk-testpmd -l 0-3 -n 4 -a 0002:01:00.2 \
-- -i --no-flush-rx \
--port-topology=loop
...
PMD: rte_nicvf_pmd_init(): librte_net_thunderx nicvf version 1.0
...
EAL: probe driver: 177d:11 rte_nicvf_pmd
EAL: using IOMMU type 1 (Type 1)
EAL: PCI memory mapped at 0x3ffade50000
EAL: Trying to map BAR 4 that contains the MSI-X table.
Trying offsets: 0x40000000000:0x0000, 0x10000:0x1f0000
EAL: PCI memory mapped at 0x3ffadc60000
PMD: nicvf_eth_dev_init(): nicvf: device (177d:11) 2:1:0:2
PMD: nicvf_eth_dev_init(): node=0 vf=1 mode=tns-bypass sqs=false
loopback_supported=true
PMD: nicvf_eth_dev_init(): Port 0 (177d:11) mac=a6:c6:d9:17:78:01
Interactive-mode selected
Configuring Port 0 (socket 0)
...
PMD: nicvf_dev_configure(): Configured ethdev port0 hwcap=0x0
Port 0: A6:C6:D9:17:78:01
Checking link statuses...
Port 0 Link Up - speed 10000 Mbps - full-duplex
Done
testpmd>
Multiple Queue Set per DPDK port configuration
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
There are two types of VFs:
- Primary VF
- Secondary VF
Each port consists of a primary VF and n secondary VF(s). Each VF provides 8 Tx/Rx queues to a port.
When a given port is configured to use more than 8 queues, it requires one (or more) secondary VF.
Each secondary VF adds 8 additional queues to the queue set.
During PMD initialization, the primary VF's are enumerated by checking the
specific flag (see sqs message in DPDK boot log - sqs indicates secondary queue set).
They are at the beginning of VF list (the remain ones are secondary VF's).
The primary VFs are used as master queue sets. Secondary VFs provide
additional queue sets for primary ones. If a port is configured for more then
8 queues than it will request for additional queues from secondary VFs.
Secondary VFs cannot be shared between primary VFs.
Primary VFs are present on the beginning of the 'Network devices using kernel
driver' list, secondary VFs are on the remaining on the remaining part of the list.
.. note::
The VNIC driver in the multiqueue setup works differently than other drivers like `ixgbe`.
We need to bind separately each specific queue set device with the ``usertools/dpdk-devbind.py`` utility.
.. note::
Depending on the hardware used, the kernel driver sets a threshold ``vf_id``. VFs that try to attached with an id below or equal to
this boundary are considered primary VFs. VFs that try to attach with an id above this boundary are considered secondary VFs.
LBK HW Access
~~~~~~~~~~~~~
Loopback HW Unit (LBK) receives packets from NIC-RX and sends packets back to NIC-TX.
The loopback block has N channels and contains data buffering that is shared across
all channels. Four primary VFs are reserved as loopback ports.
Example device binding
~~~~~~~~~~~~~~~~~~~~~~
If a system has three interfaces, a total of 18 VF devices will be created
on a non-NUMA machine.
.. note::
NUMA systems have 12 VFs per port and non-NUMA 6 VFs per port.
.. code-block:: console
# usertools/dpdk-devbind.py --status
Network devices using DPDK-compatible driver
============================================
<none>
Network devices using kernel driver
===================================
0000:01:10.0 'THUNDERX BGX (Common Ethernet Interface) a026' if= drv=thunder-BGX unused=vfio-pci
0000:01:10.1 'THUNDERX BGX (Common Ethernet Interface) a026' if= drv=thunder-BGX unused=vfio-pci
0001:01:00.0 'THUNDERX Network Interface Controller a01e' if= drv=thunder-nic unused=vfio-pci
0001:01:00.1 'Device a034' if=eth0 drv=thunder-nicvf unused=vfio-pci
0001:01:00.2 'Device a034' if=eth1 drv=thunder-nicvf unused=vfio-pci
0001:01:00.3 'Device a034' if=eth2 drv=thunder-nicvf unused=vfio-pci
0001:01:00.4 'Device a034' if=eth3 drv=thunder-nicvf unused=vfio-pci
0001:01:00.5 'Device a034' if=eth4 drv=thunder-nicvf unused=vfio-pci
0001:01:00.6 'Device a034' if=lbk0 drv=thunder-nicvf unused=vfio-pci
0001:01:00.7 'Device a034' if=lbk1 drv=thunder-nicvf unused=vfio-pci
0001:01:01.0 'Device a034' if=lbk2 drv=thunder-nicvf unused=vfio-pci
0001:01:01.1 'Device a034' if=lbk3 drv=thunder-nicvf unused=vfio-pci
0001:01:01.2 'Device a034' if= drv=thunder-nicvf unused=vfio-pci
0001:01:01.3 'Device a034' if= drv=thunder-nicvf unused=vfio-pci
0001:01:01.4 'Device a034' if= drv=thunder-nicvf unused=vfio-pci
0001:01:01.5 'Device a034' if= drv=thunder-nicvf unused=vfio-pci
0001:01:01.6 'Device a034' if= drv=thunder-nicvf unused=vfio-pci
0001:01:01.7 'Device a034' if= drv=thunder-nicvf unused=vfio-pci
0001:01:02.0 'Device a034' if= drv=thunder-nicvf unused=vfio-pci
0001:01:02.1 'Device a034' if= drv=thunder-nicvf unused=vfio-pci
0001:01:02.2 'Device a034' if= drv=thunder-nicvf unused=vfio-pci
Other network devices
=====================
0002:00:03.0 'Device a01f' unused=vfio-pci,uio_pci_generic
.. note::
Here total no of primary VFs = 5 (variable, depends on no of ethernet ports present) + 4 (fixed, loopback ports).
Ethernet ports are indicated as `if=eth0` while loopback ports as `if=lbk0`.
We want to bind two physical interfaces with 24 queues each device, we attach two primary VFs
and four secondary VFs. In our example we choose two 10G interfaces eth1 (0002:01:00.2) and eth2 (0002:01:00.3).
We will choose four secondary queue sets from the ending of the list (0001:01:01.2-0002:01:02.2).
#. Bind two primary VFs to the ``vfio-pci`` driver:
.. code-block:: console
usertools/dpdk-devbind.py -b vfio-pci 0002:01:00.2
usertools/dpdk-devbind.py -b vfio-pci 0002:01:00.3
#. Bind four primary VFs to the ``vfio-pci`` driver:
.. code-block:: console
usertools/dpdk-devbind.py -b vfio-pci 0002:01:01.7
usertools/dpdk-devbind.py -b vfio-pci 0002:01:02.0
usertools/dpdk-devbind.py -b vfio-pci 0002:01:02.1
usertools/dpdk-devbind.py -b vfio-pci 0002:01:02.2
The nicvf thunderx driver will make use of attached secondary VFs automatically during the interface configuration stage.
Thunder-nic VF's
~~~~~~~~~~~~~~~~
Use sysfs to distinguish thunder-nic primary VFs and secondary VFs.
.. code-block:: console
ls -l /sys/bus/pci/drivers/thunder-nic/
total 0
drwxr-xr-x 2 root root 0 Jan 22 11:19 ./
drwxr-xr-x 86 root root 0 Jan 22 11:07 ../
lrwxrwxrwx 1 root root 0 Jan 22 11:19 0001:01:00.0 -> '../../../../devices/platform/soc@0/849000000000.pci/pci0001:00/0001:00:10.0/0001:01:00.0'/
.. code-block:: console
cat /sys/bus/pci/drivers/thunder-nic/0001\:01\:00.0/sriov_sqs_assignment
12
0 0001:01:00.1 vfio-pci +: 12 13
1 0001:01:00.2 thunder-nicvf -:
2 0001:01:00.3 thunder-nicvf -:
3 0001:01:00.4 thunder-nicvf -:
4 0001:01:00.5 thunder-nicvf -:
5 0001:01:00.6 thunder-nicvf -:
6 0001:01:00.7 thunder-nicvf -:
7 0001:01:01.0 thunder-nicvf -:
8 0001:01:01.1 thunder-nicvf -:
9 0001:01:01.2 thunder-nicvf -:
10 0001:01:01.3 thunder-nicvf -:
11 0001:01:01.4 thunder-nicvf -:
12 0001:01:01.5 vfio-pci: 0
13 0001:01:01.6 vfio-pci: 0
14 0001:01:01.7 thunder-nicvf: 255
15 0001:01:02.0 thunder-nicvf: 255
16 0001:01:02.1 thunder-nicvf: 255
17 0001:01:02.2 thunder-nicvf: 255
18 0001:01:02.3 thunder-nicvf: 255
19 0001:01:02.4 thunder-nicvf: 255
20 0001:01:02.5 thunder-nicvf: 255
21 0001:01:02.6 thunder-nicvf: 255
22 0001:01:02.7 thunder-nicvf: 255
23 0001:01:03.0 thunder-nicvf: 255
24 0001:01:03.1 thunder-nicvf: 255
25 0001:01:03.2 thunder-nicvf: 255
26 0001:01:03.3 thunder-nicvf: 255
27 0001:01:03.4 thunder-nicvf: 255
28 0001:01:03.5 thunder-nicvf: 255
29 0001:01:03.6 thunder-nicvf: 255
30 0001:01:03.7 thunder-nicvf: 255
31 0001:01:04.0 thunder-nicvf: 255
Every column that ends with 'thunder-nicvf: number' can be used as secondary VF.
In printout above all entres after '14 0001:01:01.7 thunder-nicvf: 255' can be used as secondary VF.
Debugging Options
-----------------
EAL command option to change log level
.. code-block:: console
--log-level=pmd.net.thunderx.driver:info
or
--log-level=pmd.net.thunderx.driver,7
Runtime Configuration
---------------------
skip_data_bytes
~~~~~~~~~~~~~~~
This feature is used to create a hole between HEADROOM and actual data. Size of hole is specified
in bytes as module param("skip_data_bytes") to PMD.
This scheme is useful when application would like to insert vlan header without disturbing HEADROOM.
Example:
.. code-block:: console
-a 0002:01:00.2,skip_data_bytes=8
Limitations
-----------
CRC stripping
~~~~~~~~~~~~~
The ThunderX SoC family NICs strip the CRC for every packets coming into the
host interface irrespective of the offload configuration.
Maximum packet length
~~~~~~~~~~~~~~~~~~~~~
The ThunderX SoC family NICs support a maximum of a 9K jumbo frame. The value
is fixed and cannot be changed. So, even when the ``rxmode.mtu``
member of ``struct rte_eth_conf`` is set to a value lower than 9200, frames
up to 9200 bytes can still reach the host interface.
Maximum packet segments
~~~~~~~~~~~~~~~~~~~~~~~
The ThunderX SoC family NICs support up to 12 segments per packet when working
in scatter/gather mode. So, setting MTU will result with ``EINVAL`` when the
frame size does not fit in the maximum number of segments.
skip_data_bytes
~~~~~~~~~~~~~~~