1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100
|
#!/bin/sh
# (C) Copyright 2005- ECMWF.
#
# This software is licensed under the terms of the Apache Licence Version 2.0
# which can be obtained at http://www.apache.org/licenses/LICENSE-2.0.
#
# In applying this licence, ECMWF does not waive the privileges and immunities granted to it by
# virtue of its status as an intergovernmental organisation nor does it submit to any jurisdiction.
#
. ./include.ctest.sh
label="grib_cmp_paramtype_test"
tempGrib=temp.$label.grib
tempFilt=temp.$label.filt
sample_grib2=$ECCODES_SAMPLES_PATH/GRIB2.tmpl
# wave_spectra
cat >$tempFilt<<EOF
set setLocalDefinition=1;
set class='e6';
set tablesVersion=34;
set productDefinitionTemplateNumber=99;
write;
EOF
${tools_dir}/grib_filter -o $tempGrib $tempFilt $sample_grib2
grib_check_key_equals $tempGrib paramtype "wave_spectra"
# wave
cat >$tempFilt<<EOF
set setLocalDefinition=1;
set class='e6';
set tablesVersion=34;
set discipline=10;
set parameterCategory=0;
set parameterNumber=3;
write;
EOF
${tools_dir}/grib_filter -o $tempGrib $tempFilt $sample_grib2
grib_check_key_equals $tempGrib paramtype "wave"
# chem in ERA6 as paramtype base
cat >$tempFilt<<EOF
set setLocalDefinition=1;
set class='e6';
set tablesVersion=34;
set productDefinitionTemplateNumber=50;
write;
EOF
${tools_dir}/grib_filter -o $tempGrib $tempFilt $sample_grib2
grib_check_key_equals $tempGrib paramtype "base"
# chem in CAMS as paramtype chemical
cat >$tempFilt<<EOF
set setLocalDefinition=1;
set class='mc';
set tablesVersion=34;
set productDefinitionTemplateNumber=50;
write;
EOF
${tools_dir}/grib_filter -o $tempGrib $tempFilt $sample_grib2
grib_check_key_equals $tempGrib paramtype "chemical"
# chem/optical in ERA6 as paramtype optical
cat >$tempFilt<<EOF
set setLocalDefinition=1;
set class='e6';
set tablesVersion=34;
set productDefinitionTemplateNumber=48;
write;
EOF
${tools_dir}/grib_filter -o $tempGrib $tempFilt $sample_grib2
grib_check_key_equals $tempGrib paramtype "optical"
# chem/optical in CAMS as paramtype chemical_optical
cat >$tempFilt<<EOF
set setLocalDefinition=1;
set class='mc';
set tablesVersion=34;
set productDefinitionTemplateNumber=48;
write;
EOF
${tools_dir}/grib_filter -o $tempGrib $tempFilt $sample_grib2
grib_check_key_equals $tempGrib paramtype "chemical_optical"
# base
cat >$tempFilt<<EOF
set setLocalDefinition=1;
set class='e6';
set tablesVersion=34;
set productDefinitionTemplateNumber=0;
write;
EOF
${tools_dir}/grib_filter -o $tempGrib $tempFilt $sample_grib2
grib_check_key_equals $tempGrib paramtype "base"
# Clean up
rm -f $tempGrib $tempFilt
|