File: test_h2o_125_hf.sh

package info (click to toggle)
ergo 3.5-1
  • links: PTS, VCS
  • area: main
  • in suites: buster, stretch
  • size: 17,044 kB
  • ctags: 6,813
  • sloc: cpp: 91,488; ansic: 15,728; sh: 6,416; makefile: 1,287; yacc: 123; lex: 108
file content (157 lines) | stat: -rwxr-xr-x 3,625 bytes parent folder | download
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
#!/bin/sh

# Run each test in a separate directory, to allow "make check -j" to work properly.
currtestdirname=tmpdir_test_h2o_125_hf

rm -rf $currtestdirname
mkdir $currtestdirname
cd $currtestdirname

if [ "$top_builddir" = "" ] || [ "$top_builddir" = ".." ] ; then
    top_builddir=../..
fi
if [ "$top_srcdir" = "" ] || [ "$top_srcdir" = ".." ] ; then
    top_srcdir=../..
fi

if test `"$top_builddir"/source/ergo -e precision` = single; then
    echo SKIPPED
    exit 0
fi

. "$top_srcdir"/test/functions

errorfilename=ergoscf.out.error.h2o_125

guess_input='
basis = "STO-2G";
use_simple_starting_guess=1;
J_K.threshold_2el_J = 1e-6;
J_K.threshold_2el_K = 1e-6;
J_K.fmm_box_size = 10.0;
scf.convergence_threshold = 1e-2;
run "HF";
'

echo

echo Testing h2o_125_1 HF/6-31G**
rm -f ergoscf.out
echo getting starting guess...
echo $guess_input | "$top_builddir"/source/ergo -m "$top_srcdir"/mol/h2o_125_1.xyz > /dev/null
rm -f ergoscf.out
echo running HF/6-31Gss...
"$top_builddir"/source/ergo -m ../mol/h2o_125_1.xyz <<EOINPUT > /dev/null
enable_memory_usage_output = 1
basis = "6-31Gss"
initial_density = "density.bin"
J_K.threshold_2el_J = 1e-10
J_K.threshold_2el_K = 1e-10
scf.convergence_threshold = 1e-5
run "HF"
EOINPUT
if 
check_final_energy -9502.8355138 2e-6 ; 
then
echo OK
grep CONVERGED ergoscf.out
mv ergoscf.out ergoscf.out.1
else
echo ERROR
mv ergoscf.out $errorfilename
echo output file saved as $errorfilename
exit 1
fi

echo Testing h2o_125_2 HF/6-31G**
rm -f ergoscf.out
echo getting starting guess...
echo $guess_input | "$top_builddir"/source/ergo -m "$top_srcdir"/mol/h2o_125_2.xyz > /dev/null
rm -f ergoscf.out
echo running HF/6-31Gss...
"$top_builddir"/source/ergo -m ../mol/h2o_125_2.xyz <<EOINPUT > /dev/null
enable_memory_usage_output = 1
basis = "6-31Gss"
initial_density = "density.bin"
J_K.threshold_2el_J = 1e-10
J_K.threshold_2el_K = 1e-10
scf.convergence_threshold = 1e-5
run "HF"
EOINPUT
if 
check_final_energy -9502.8404831 2e-6 ;
then
echo OK
grep CONVERGED ergoscf.out
mv ergoscf.out ergoscf.out.2
else
echo ERROR
mv ergoscf.out $errorfilename
echo output file saved as $errorfilename
exit 1
fi

echo Testing h2o_125_3 HF/6-31G**
rm -f ergoscf.out
echo getting starting guess...
echo $guess_input | "$top_builddir"/source/ergo -m "$top_srcdir"/mol/h2o_125_3.xyz > /dev/null
rm -f ergoscf.out
echo running HF/6-31Gss...
"$top_builddir"/source/ergo -m ../mol/h2o_125_3.xyz <<EOINPUT > /dev/null
enable_memory_usage_output = 1
basis = "6-31Gss"
initial_density = "density.bin"
J_K.threshold_2el_J = 1e-10
J_K.threshold_2el_K = 1e-10
scf.convergence_threshold = 1e-5
run "HF"
EOINPUT
if 
check_final_energy -9502.8284608 2e-6 ;
then
echo OK
grep CONVERGED ergoscf.out
mv ergoscf.out ergoscf.out.3
else
echo ERROR
mv ergoscf.out $errorfilename
echo output file saved as $errorfilename
exit 1
fi

echo Testing h2o_125_4 HF/6-31G**
rm -f ergoscf.out
echo getting starting guess...
echo $guess_input | "$top_builddir"/source/ergo -m "$top_srcdir"/mol/h2o_125_4.xyz > /dev/null
rm -f ergoscf.out
echo running HF/6-31Gss...
"$top_builddir"/source/ergo -m ../mol/h2o_125_4.xyz <<EOINPUT > /dev/null
enable_memory_usage_output = 1
basis = "6-31Gss"
initial_density = "density.bin"
J_K.threshold_2el_J = 1e-10
J_K.threshold_2el_K = 1e-10
scf.convergence_threshold = 1e-5
run "HF"
EOINPUT
if 
check_final_energy -9502.8359906 2e-6 ;
then
echo OK
grep CONVERGED ergoscf.out
mv ergoscf.out ergoscf.out.4
else
echo ERROR
mv ergoscf.out $errorfilename
echo output file saved as $errorfilename
exit 1
fi



cd ..
rm -r $currtestdirname

echo
echo h2o_125 Hartree-Fock tests completed successfully!
echo