File: snmp_notification_mib.html

package info (click to toggle)
erlang-doc-html 1%3A11.b.2-1
  • links: PTS
  • area: main
  • in suites: etch, etch-m68k
  • size: 23,284 kB
  • ctags: 10,724
  • sloc: erlang: 505; ansic: 323; makefile: 62; perl: 61; sh: 45
file content (177 lines) | stat: -rw-r--r-- 4,630 bytes parent folder | download
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<!-- This document was generated using DocBuilder 3.3.3 -->
<HTML>
<HEAD>
  <TITLE>snmp_notification_mib</TITLE>
  <SCRIPT type="text/javascript" src="../../../../doc/erlresolvelinks.js">
</SCRIPT>
  <STYLE TYPE="text/css">
<!--
    .REFBODY     { margin-left: 13mm }
    .REFTYPES    { margin-left: 8mm }
-->
  </STYLE>
</HEAD>
<BODY BGCOLOR="#FFFFFF" TEXT="#000000" LINK="#0000FF" VLINK="#FF00FF"
      ALINK="#FF0000">
<!-- refpage -->
<CENTER>
<A HREF="http://www.erlang.se">
  <IMG BORDER=0 ALT="[Ericsson AB]" SRC="min_head.gif">
</A>
<H1>snmp_notification_mib</H1>
</CENTER>

<H3>MODULE</H3>
<DIV CLASS=REFBODY>
snmp_notification_mib
</DIV>

<H3>MODULE SUMMARY</H3>
<DIV CLASS=REFBODY>
Instrumentation Functions for
SNMP-NOTIFICATION-MIB
</DIV>

<H3>DESCRIPTION</H3>
<DIV CLASS=REFBODY>

<P>The module <CODE>snmp_notification_mib</CODE> implements the
instrumentation functions for the
SNMP-NOTIFICATION-MIB, and functions for configuring the database.


<P>The configuration files are described in the SNMP User's Manual.

</DIV>

<H3>EXPORTS</H3>

<P><A NAME="configure/1"><STRONG><CODE>configure(ConfDir) -&#62; void()</CODE></STRONG></A><BR>

<DIV CLASS=REFBODY><P>Types:
  <DIV CLASS=REFTYPES>
<P>
<STRONG><CODE>ConfDir = string()</CODE></STRONG><BR>

  </DIV>
</DIV>

<DIV CLASS=REFBODY>

<P>This function is called from the supervisor at system
        start-up.

        
<P>Inserts all data in the configuration files into the
        database and destroys all old rows with StorageType
        <CODE>volatile</CODE>. The rows created from the configuration file
        will have StorageType <CODE>nonVolatile</CODE>.

        
<P>If an error is found in the configuration file, it is
         reported using the function <CODE>config_err/2</CODE> of the 
         error report module,
         and the function fails with reason <CODE>configuration_error</CODE>.

        
<P><CODE>ConfDir</CODE> is a string which points to the directory
        where the configuration files are found.


<P>The configuration file read is: <CODE>notify.conf</CODE>.


</DIV>

<P><A NAME="reconfigure/1"><STRONG><CODE>reconfigure(ConfDir) -&#62; void()</CODE></STRONG></A><BR>

<DIV CLASS=REFBODY><P>Types:
  <DIV CLASS=REFTYPES>
<P>
<STRONG><CODE>ConfDir = string()</CODE></STRONG><BR>

  </DIV>
</DIV>

<DIV CLASS=REFBODY>

<P>Inserts all data in the configuration files into the
        database and destroys all old data, including the rows with
        StorageType <CODE>nonVolatile</CODE>. The rows created from the
        configuration file will have StorageType <CODE>nonVolatile</CODE>.


<P>Thus, the data in the SNMP-NOTIFICATION-MIB, after this
         function has been called, is from the configuration files.

        
<P>If an error is found in the configuration file, it is
         reported using the function <CODE>config_err/2</CODE> of the 
         error report module,
         and the function fails with reason <CODE>configuration_error</CODE>.

        
<P><CODE>ConfDir</CODE> is a string which points to the directory
        where the configuration files are found.


<P>The configuration file read is: <CODE>notify.conf</CODE>.

        <A NAME="add_notify"><!-- Empty --></A> 


</DIV>

<P><A NAME="add_notify/3"><STRONG><CODE>add_notify(Name, Tag, Type) -&#62; Ret</CODE></STRONG></A><BR>

<DIV CLASS=REFBODY><P>Types:
  <DIV CLASS=REFTYPES>
<P>
<STRONG><CODE>Name = string()</CODE></STRONG><BR>
<STRONG><CODE>Tag = string()</CODE></STRONG><BR>
<STRONG><CODE>Type = trap | inform</CODE></STRONG><BR>
<STRONG><CODE>Ret = {ok, Key} | {error, Reason}</CODE></STRONG><BR>
<STRONG><CODE>Key = term()</CODE></STRONG><BR>
<STRONG><CODE>Reason = term()</CODE></STRONG><BR>

  </DIV>
</DIV>

<DIV CLASS=REFBODY>

<P>Adds a notify definition to the agent config. 
         Equivalent to one line in the <CODE>notify.conf</CODE> file.<A NAME="delete_notify"><!-- Empty --></A>
</DIV>

<P><A NAME="delete_notify/1"><STRONG><CODE>delete_notify(Key) -&#62; Ret</CODE></STRONG></A><BR>

<DIV CLASS=REFBODY><P>Types:
  <DIV CLASS=REFTYPES>
<P>
<STRONG><CODE>Key = term()</CODE></STRONG><BR>
<STRONG><CODE>Ret = ok | {error, Reason}</CODE></STRONG><BR>
<STRONG><CODE>Reason = term()</CODE></STRONG><BR>

  </DIV>
</DIV>

<DIV CLASS=REFBODY>

<P>Delete a notify definition from the agent config.
</DIV>

<H3>AUTHORS</H3>
<DIV CLASS=REFBODY>
Martin Bjrklund - support@erlang.ericsson.se<BR>

</DIV>
<CENTER>
<HR>
<SMALL>snmp 4.8.2<BR>
Copyright &copy; 1991-2006
<A HREF="http://www.erlang.se">Ericsson AB</A><BR>
</SMALL>
</CENTER>
</BODY>
</HTML>