1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178
|
%%
%% %CopyrightBegin%
%%
%% Copyright Ericsson AB 1996-2009. All Rights Reserved.
%%
%% The contents of this file are subject to the Erlang Public License,
%% Version 1.1, (the "License"); you may not use this file except in
%% compliance with the License. You should have received a copy of the
%% Erlang Public License along with this software. If not, it can be
%% retrieved online at http://www.erlang.org/.
%%
%% Software distributed under the License is distributed on an "AS IS"
%% basis, WITHOUT WARRANTY OF ANY KIND, either express or implied. See
%% the License for the specific language governing rights and limitations
%% under the License.
%%
%% %CopyrightEnd%
%%
-module(supervisor_bridge_SUITE).
-export([all/1,starting/1,mini_terminate/1,mini_die/1,badstart/1]).
-export([client/1,init/1,internal_loop_init/1,terminate/2]).
-include("test_server.hrl").
-define(bridge_name,supervisor_bridge_SUITE_server).
-define(work_bridge_name,work_supervisor_bridge_SUITE_server).
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
all(suite) -> [starting,mini_terminate,mini_die,badstart].
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
starting(suite) -> [];
starting(Config) when is_list(Config) ->
process_flag(trap_exit,true),
?line ignore = start(1),
?line {error,testing} = start(2),
ok.
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
mini_terminate(suite) -> [];
mini_terminate(Config) when is_list(Config) ->
miniappl(1),
ok.
mini_die(suite) -> [];
mini_die(Config) when is_list(Config) ->
miniappl(2),
ok.
miniappl(N) ->
process_flag(trap_exit,true),
?line {ok,Server} = start(3),
?line Client = spawn_link(?MODULE,client,[N]),
?line Handle = test_server:timetrap(2000),
?line miniappl_loop(Client,Server),
?line test_server:timetrap_cancel(Handle).
miniappl_loop([],[]) ->
ok;
miniappl_loop(Client,Server) ->
io:format("Client ~p, Server ~p\n",[Client,Server]),
receive
{'EXIT',Client,_} ->
?line miniappl_loop([],Server);
{'EXIT',Server,killed} -> %% terminate
?line miniappl_loop(Client,[]);
{'EXIT',Server,died} -> %% die
?line miniappl_loop(Client,[]);
{dying,_Reason} ->
?line miniappl_loop(Client, Server);
Other ->
?line exit({failed,Other})
end.
%%%%%%%%%%%%%%%%%%%%
% Client
client(N) ->
io:format("Client starting...\n"),
ok = public_request(),
case N of
1 -> public_kill();
2 -> ?work_bridge_name ! die
end,
io:format("Killed server, terminating client...\n"),
exit(fine).
%%%%%%%%%%%%%%%%%%%%
% Non compliant server
start(N) ->
supervisor_bridge:start_link({local,?bridge_name},?MODULE,N).
public_request() ->
?work_bridge_name ! {non_compliant_message,self()},
io:format("Client waiting for answer...\n"),
receive
non_compliant_answer ->
ok
end,
io:format("Client got answer...\n").
public_kill() ->
%% This func knows about supervisor_bridge
exit(whereis(?work_bridge_name),kill).
init(1) ->
ignore;
init(2) ->
{error,testing};
init(3) ->
%% This func knows about supervisor_bridge
InternalPid = spawn_link(?MODULE,internal_loop_init,[self()]),
receive
{InternalPid,init_done} ->
{ok,InternalPid,self()}
end.
internal_loop_init(Parent) ->
register(?work_bridge_name, self()),
Parent ! {self(),init_done},
internal_loop({Parent,self()}).
internal_loop(State) ->
receive
{non_compliant_message,From} ->
io:format("Got request from ~p\n",[From]),
From ! non_compliant_answer,
internal_loop(State);
die ->
exit(died)
end.
terminate(Reason,{Parent,Worker}) ->
%% This func knows about supervisor_bridge
io:format("Terminating bridge...\n"),
exit(kill,Worker),
Parent ! {dying,Reason},
anything.
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
badstart(suite) -> [];
badstart(doc) -> "Test various bad ways of starting a supervisor bridge.";
badstart(Config) when is_list(Config) ->
?line Dog = test_server:timetrap(test_server:minutes(1)),
%% Various bad arguments.
?line {'EXIT',_} =
(catch supervisor_bridge:start_link({xxx,?bridge_name},?MODULE,1)),
?line {'EXIT',_} =
(catch supervisor_bridge:start_link({local,"foo"},?MODULE,1)),
?line {'EXIT',_} =
(catch supervisor_bridge:start_link(?bridge_name,?MODULE,1)),
?line [] = test_server:messages_get(), % No messages waiting
%% Already started.
?line process_flag(trap_exit, true),
?line {ok,Pid} =
supervisor_bridge:start_link({local,?bridge_name},?MODULE,3),
?line {error,{already_started,Pid}} =
supervisor_bridge:start_link({local,?bridge_name},?MODULE,3),
?line public_kill(),
%% We used to wait 1 ms before retrieving the message queue,
%% but that might not always be enough if the machine is overloaded.
?line receive
{'EXIT', Pid, killed} -> ok
end,
?line test_server:timetrap_cancel(Dog),
ok.
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|