1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850
|
! autopilot.f90
!********************************************************************************
! autopilot.f90 Copyright (c) 2005 Targacept, Inc.
!********************************************************************************
! The Autopilot Feature suite is a user level enhancement that enables the
! following features:
! automatic restart of a job;
! preconfiguration of job parameters;
! on-the-fly changes to job parameters;
! and pausing of a running job.
!
! For more information, see README.AUTOPILOT in document directory.
!
! This program is free software; you can redistribute it and/or modify it under
! the terms of the GNU General Public License as published by the Free Software
! Foundation; either version 2 of the License, or (at your option) any later version.
! This program is distributed in the hope that it will be useful, but WITHOUT ANY
! WARRANTY; without even the implied warranty of MERCHANTABILITY FOR A PARTICULAR
! PURPOSE. See the GNU General Public License at www.gnu.or/copyleft/gpl.txt for
! more details.
!
! THERE IS NO WARRANTY FOR THE PROGRAM, TO THE EXTENT PERMITTED BY APPLICABLE LAW.
! EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND/OR OTHER PARTIES
! PROVIDE THE PROGRAM "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED,
! INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
! FITNESS FOR A PARTICULAR PURPOSE. THE ENTIRE RISK AS TO THE QUALITY AND THE
! PERFORMANCE OF THE PROGRAM IS WITH YOU. SHOULD THE PROGRAM PROVE DEFECTIVE,
! YOU ASSUME THE COST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION.
!
! IN NO EVENT UNLESS REQUIRED BY APPLICABLE LAW OR AGREED TO IN WRITING,
! WILL ANY COPYRIGHT HOLDER, OR ANY OTHER PARTY WHO MAY MODIFY AND/OR REDISTRIBUTE
! THE PROGRAM AS PERMITTED ABOVE, BE LIABLE TO YOU FOR DAMAGES, INCLUDING ANY
! GENERAL, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR
! INABILITY TO USE THE PROGRAM (INCLUDING BUT NOT LIMITED TO LOSS OF DATA OR DATA
! BEING RENDERED INACCURATE OR LOSSES SUSTAINED BY YOU OR THIRD PARTIES OR A
! FAILURE OF THE PROGRAM TO OPERATE WITH ANY OTHER PROGRAMS), EVEN IF SUCH HOLDER
! OR OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
!
! You should have received a copy of the GNU General Public License along with
! this program; if not, write to the
! Free Software Foundation, Inc.,
! 51 Franklin Street,
! Fifth Floor,
! Boston, MA 02110-1301, USA.
!
! Targacept's address is
! 200 East First Street, Suite 300
! Winston-Salem, North Carolina USA 27101-4165
! Attn: Molecular Design.
! Email: atp@targacept.com
!
! This work was supported by the Advanced Technology Program of the
! National Institute of Standards and Technology (NIST), Award No. 70NANB3H3065
!
!********************************************************************************
MODULE autopilot
!---------------------------------------------------------------------------
!
! This module handles the Autopilot Feature Suite
! Written by Lee Atkinson, with help from the ATP team at Targacept, Inc
! Created June 2005
! Modified by Yonas Abraham, Sept 2006
!
! The address for Targacept, Inc. is:
! 200 East First Street, Suite
! 300, Winston-Salem, North Carolina 27101;
! Attn: Molecular Design.
!
! See README.AUTOPILOT in the Doc directory for more information.
!---------------------------------------------------------------------------
USE kinds
USE parser, ONLY : read_line
IMPLICIT NONE
SAVE
INTEGER, parameter :: MAX_INT = huge(1)
INTEGER, parameter :: max_event_step = 32 !right now there can be upto 32 Autopilot Events
INTEGER, parameter :: n_auto_vars = 10 !right now there are only 10 Autopilot Variables
INTEGER :: n_events
INTEGER :: event_index = 0
INTEGER :: max_rules = 320 !(max_event_step * n_auto_vars)
INTEGER :: n_rules
INTEGER :: event_step(max_event_step)
INTEGER :: current_nfi
LOGICAL :: pilot_p = .FALSE. ! pilot property
LOGICAL :: restart_p = .FALSE. ! restart property
LOGICAL :: pause_p = .FALSE. ! pause property
INTEGER :: pilot_unit = 42 ! perhaps move this to io_files
CHARACTER(LEN=256) :: pilot_type
! AUTOPILOT VARIABLES
! These are the variable tables which change the actual variable
! dynamically during the course of a simulation. There are many
! parameters which govern a simulation, yet only these are allowed
! to be changed using the event rule mechanism.
! Each of these tables are ytped according to their variable
! and begin with event_
! &CONTROL
INTEGER :: rule_isave(max_event_step)
INTEGER :: rule_iprint(max_event_step)
REAL(DP) :: rule_dt(max_event_step)
! &SYSTEM
! &ELECTRONS
REAL(DP) :: rule_emass(max_event_step)
CHARACTER(LEN=80) :: rule_electron_dynamics(max_event_step)
REAL(DP) :: rule_electron_damping(max_event_step)
! &IONS
CHARACTER(LEN=80) :: rule_ion_dynamics(max_event_step)
REAL(DP) :: rule_ion_damping(max_event_step)
CHARACTER(LEN=80) :: rule_ion_temperature(max_event_step)
REAL(DP) :: rule_tempw(max_event_step)
! &CELL
! &PHONON
! Each rule also needs to be correlated (flagged) against the event time table
! This is used to flag the a given variable is to be changed on an
! event. Initially all set to false, a rule against an event makes it true
! Each of these flags are LOGICALs and begin with event_
! &CONTROL
LOGICAL :: event_isave(max_event_step)
LOGICAL :: event_iprint(max_event_step)
LOGICAL :: event_dt(max_event_step)
! &SYSTEM
! &ELECTRONS
LOGICAL :: event_emass(max_event_step)
LOGICAL :: event_electron_dynamics(max_event_step)
LOGICAL :: event_electron_damping(max_event_step)
! &IONS
LOGICAL :: event_ion_dynamics(max_event_step)
LOGICAL :: event_ion_damping(max_event_step)
LOGICAL :: event_ion_temperature(max_event_step)
LOGICAL :: event_tempw(max_event_step)
! &CELL
! &PHONON
PRIVATE
PUBLIC :: auto_check, init_autopilot, card_autopilot, add_rule, &
& assign_rule, restart_p, max_event_step, event_index, event_step, rule_isave, &
& rule_iprint, rule_dt, rule_emass, rule_electron_dynamics, rule_electron_damping, &
& rule_ion_dynamics, rule_ion_damping, rule_ion_temperature, rule_tempw, &
& event_isave, event_iprint, event_dt, event_emass, &
& event_electron_dynamics, event_electron_damping, event_ion_dynamics, &
& current_nfi, pilot_p, pilot_unit, pause_p,auto_error, parse_mailbox, &
& event_ion_damping, event_ion_temperature, event_tempw
CONTAINS
!----------------------------------------------------------------------------
SUBROUTINE auto_error( calling_routine, message)
!----------------------------------------------------------------------------
! This routine calls errore based upon the pilot property flag.
! If the flag is TRUE, the simulation will not stop,
! but the pause property flag is set to TRUE,
! causing pilot to force a state of sleep,
! until the user can mail proper commands.
! Otherwise, its assumed that dynamics have not started
! and this call is an indirect result of read_cards.
! Thus the simulation will stop.
! Either way errore will always issues a warning message.
USE io_global, ONLY : ionode_id
USE mp, ONLY : mp_bcast
USE mp_world, ONLY : world_comm
IMPLICIT NONE
!
CHARACTER(LEN=*), INTENT(IN) :: calling_routine, message
! the name of the calling calling_routinee
! the output message
INTEGER :: ierr
! the error flag
IF (pilot_p) THEN
! if ierr < 0 errore writes the message but does not stop
ierr = -1
pause_p = .TRUE.
!call mp_bcast(pause_p, ionode_id, world_comm)
ELSE
! if ierr > 0 it stops
ierr = 1
ENDIF
CALL errore( calling_routine, message, ierr )
END SUBROUTINE auto_error
!-----------------------------------------------------------------------
! AUTO (restart) MODE
!
! Checks if restart files are present, just like what readfile_cp does,
! which calls cp_readfile which create a path to restart.xml.
! This could be checked with inquire, as in check_restartfile.
! If restart_mode=auto, and restart.xml is present,
! then restart_mode="restart", else its "from_scratch".
! Set other associated vars, appropriately.
!
! Put this in setcontrol_flags on the select statement
!-----------------------------------------------------------------------
LOGICAL FUNCTION auto_check (ndr, outdir)
USE io_global, ONLY: ionode, ionode_id
USE mp, ONLY : mp_bcast
USE mp_world, ONLY : world_comm
IMPLICIT NONE
INTEGER, INTENT(IN) :: ndr ! I/O unit number
CHARACTER(LEN=*), INTENT(IN) :: outdir
CHARACTER(LEN=256) :: dirname, filename
CHARACTER (LEN=6), EXTERNAL :: int_to_char
LOGICAL :: restart_p = .FALSE.
INTEGER :: strlen
! right now cp_readfile is called with outdir = ' '
! so, in keeping with the current design,
! the responsibility of setting
! ndr and outdir is the calling program
IF (ionode) THEN
dirname = 'RESTART' // int_to_char( ndr )
IF ( LEN( outdir ) > 1 ) THEN
strlen = index(outdir,' ') - 1
dirname = outdir(1:strlen) // '/' // dirname
END IF
filename = TRIM( dirname ) // '/' // 'restart.xml'
INQUIRE( FILE = TRIM( filename ), EXIST = restart_p )
auto_check = restart_p
END IF
CALL mp_bcast(auto_check, ionode_id, world_comm)
return
END FUNCTION auto_check
!-----------------------------------------------------------------------
! INITIALIZE AUTOPILOT
!
! Must be done, even if not in use.
! Add this as a call in read_cards.f90 sub: card_default_values
!-----------------------------------------------------------------------
SUBROUTINE init_autopilot
IMPLICIT NONE
integer :: event
pause_p = .FALSE.
! Initialize all events to an iteration that should never occur
DO event=1,max_event_step
event_step(event) = MAX_INT
ENDDO
n_events = 0
n_rules = 0
event_index = 1
! Initialize here
! &CONTROL
event_isave(:) = .false.
event_iprint(:) = .false.
event_dt(:) = .false.
! &SYSTEM
! &ELECTRONS
event_emass(:) = .false.
event_electron_dynamics(:) = .false.
event_electron_damping(:) = .false.
! &IONS
event_ion_dynamics(:) = .false.
event_ion_damping(:) = .false.
event_ion_temperature(:) = .false.
event_tempw(:) = .false.
! &CELL
! &PHONON
rule_isave(:) = 0
rule_iprint(:) = 0
rule_dt(:) = 0.0_DP
rule_emass(:) = 0.0_DP
rule_electron_dynamics(:) = 'NONE'
rule_electron_damping(:) = 0.0_DP
rule_ion_dynamics(:) = 'NONE'
rule_ion_damping(:) = 0.0_DP
rule_ion_temperature(:) = 'NOT_CONTROLLED'
rule_tempw(:) = 0.01_DP
END SUBROUTINE init_autopilot
!-----------------------------------------------------------------------
! subroutine CARD_AUTOPILOT
!
! called in READ_CARDS and in PARSE_MAILBOX
!-----------------------------------------------------------------------
SUBROUTINE card_autopilot( input_line )
USE io_global, ONLY: ionode, ionode_id
USE mp, ONLY : mp_bcast
USE mp_world, ONLY : world_comm
IMPLICIT NONE
INTEGER :: i, j, linelen
CHARACTER(LEN=256) :: input_line
LOGICAL :: process_this_line = .FALSE.
LOGICAL :: endrules = .FALSE.
LOGICAL :: tend = .FALSE.
LOGICAL, SAVE :: tread = .FALSE.
LOGICAL, EXTERNAL :: matches
CHARACTER(LEN=1), EXTERNAL :: capital
!ASU: copied this here since it seems not to be executed during each
! call of the routine. Needed for multiple rules in same block
process_this_line = .FALSE.
endrules = .FALSE.
tend = .FALSE.
tread = .FALSE.
! This is so we do not read a autopilot card twice from the input file
IF (( .NOT. pilot_p ) .and. tread ) THEN
CALL errore( ' card_autopilot ', ' two occurrences', 2 )
END IF
! If this routined has been called from parse_mailbox
! the pilot_type should be set
IF ( pilot_p ) THEN
! IF its MANUAL then process this line first!
! other skip this line and get the next
IF (TRIM(pilot_type) .eq. 'MANUAL') THEN
process_this_line = .TRUE.
ELSE IF (TRIM(pilot_type) .eq. 'PILOT') THEN
process_this_line = .FALSE.
ELSE IF (TRIM(pilot_type) .eq. 'AUTO') THEN
process_this_line = .FALSE.
ELSE
IF( ionode ) WRITE(*,*) 'AUTOPILOT: UNRECOGNIZED PILOT TYPE!', TRIM(pilot_type), '===='
GO TO 10
END IF
ELSE
! this routine is called from read_cards
pilot_type = 'AUTO'
process_this_line = .FALSE.
END IF
j=0
! must use a local (j) since n_rules may not get updated correctly
DO WHILE ((.NOT. endrules) .and. j<=max_rules)
j=j+1
IF (j > max_rules) THEN
CALL auto_error( ' AutoPilot ','Maximum Number of Dynamic Rules May Have Been Execced!')
go to 10
END IF
! Assume that pilot_p is an indicator and that
! this call to card_autopilot is from parse_mailbox
! and not from read_cards
IF(pilot_p) THEN
IF ( .NOT. process_this_line ) THEN
! get the next one
CALL read_line( input_line, end_of_file = tend)
END IF
ELSE
! from read_cards
CALL read_line( input_line, end_of_file = tend)
END IF
linelen = LEN_TRIM( input_line )
DO i = 1, linelen
input_line( i : i ) = capital( input_line( i : i ) )
END DO
! If ENDRULES isnt found, add_rule will fail
! and we run out of line anyway
IF ( tend .or. matches( 'ENDRULES', input_line ) ) GO TO 10
! Assume this is a rule
CALL ADD_RULE(input_line)
! now, do not process this line anymore
! make sure we get the next one
process_this_line = .FALSE.
END DO
IF( ionode ) WRITE(*,*) 'AUTOPILOT SET'
10 CONTINUE
END SUBROUTINE card_autopilot
!-----------------------------------------------------------------------
! ADD RULE
!-----------------------------------------------------------------------
SUBROUTINE add_rule( input_line )
USE io_global, ONLY: ionode, ionode_id
IMPLICIT NONE
integer :: i, j, linelen
integer :: eq1_pos, eq2_pos, plus_pos, colon_pos
CHARACTER(LEN=256) :: input_line
CHARACTER(LEN=32) :: var_label
CHARACTER(LEN=32) :: value_str
INTEGER :: on_step, now_step, plus_step
integer :: ios
integer :: event
LOGICAL, EXTERNAL :: matches
CHARACTER(LEN=1), EXTERNAL :: capital
! this is a temporary local variable
event = n_events
! important for parsing
i=0
j=0
eq1_pos = 0
eq2_pos = 0
plus_pos = 0
colon_pos = 0
linelen=LEN_TRIM( input_line )
! Attempt to get PLUS SYMBOL
i = 1
do while( (plus_pos .eq. 0) .and. (i <= linelen) )
i = i + 1
if(input_line( i : i ) .eq. '+') then
plus_pos = i
endif
end do
! Attempt to get a colon
i = 1
do while( (colon_pos .eq. 0) .and. (i <= linelen) )
i = i + 1
if(input_line( i : i ) .eq. ':') then
colon_pos = i
endif
end do
! Attempt to get first equals
i = 1
do while( (eq1_pos .eq. 0) .and. (i <= linelen) )
i = i + 1
if(input_line( i : i ) .eq. '=') then
eq1_pos = i
endif
end do
! Attempt to get second equals
if ((eq1_pos .ne. 0) .and. (eq1_pos < colon_pos)) then
i = colon_pos + 1
do while( (eq2_pos .eq. 0) .and. (i <= linelen) )
i = i + 1
if(input_line( i : i ) .eq. '=') then
eq2_pos = i
endif
end do
endif
! Complain if there is a bad parse
if (colon_pos .eq. 0) then
call auto_error( ' AutoPilot ','Missing colon separator')
go to 20
endif
if (eq1_pos .eq. 0) then
call auto_error( ' AutoPilot ','Missing equals sign')
go to 20
endif
if ((plus_pos > 0) .and. (eq1_pos < colon_pos)) then
call auto_error( ' AutoPilot ','equals and plus found prior to colon')
go to 20
endif
!================================================================================
! Detect events
IF ( (pilot_type .eq. 'MANUAL') .or. (pilot_type .eq. 'PILOT') ) THEN
!-------------------------------------------
!Do the equivalent of the following:
!READ(input_line, *) now_label, plus_label1, plus_step, colon_label, var_label, eq_label2, value_str
!Format:
! [NOW [+ plus_step] :] var_label = value_str
!-------------------------------------------
! if there is a NOW, get it and try to get plus and plus_step
IF ( matches( 'NOW', input_line ) ) THEN
! Attempt to get PLUS_STEP
plus_step = 0
! if all is non-trivial, read a PLUS_STEP
if ((plus_pos > 0) .and. (colon_pos > plus_pos)) then
! assume a number lies between
read(input_line(plus_pos+1:colon_pos-1),*,iostat=ios) plus_step
if(ios .ne. 0) then
CALL auto_error( ' AutoPilot ','Value Type Mismatch on NOW line!')
go to 20
end if
end if
! set NOW event
now_step = current_nfi + plus_step
ELSE
! set NOW event
now_step = current_nfi
END IF
!================================================================================
! set event
!
! Heres where it get interesting
! We may have a new event , or not! :)
IF ( ((event-1) .gt. 0) .and. ( now_step .lt. event_step(event-1)) ) THEN
IF( ionode ) write(*,*) ' AutoPilot: current input_line', input_line
CALL auto_error( ' AutoPilot ','Dynamic Rule Event Out of Order!')
go to 20
ENDIF
IF ( (event .eq. 0) .or. ( now_step .gt. event_step(event)) ) THEN
! new event
event = event + 1
IF (event > max_event_step) THEN
IF( ionode ) write(*,*) ' AutoPilot: current input_line', input_line
CALL auto_error( ' AutoPilot ','Maximum Number of Dynamic Rule Event Exceeded!')
go to 20
ENDIF
event_step(event) = now_step
n_events = event
ENDIF
ELSE IF ( matches( 'ON_STEP', input_line ) ) THEN
! Assuming pilot_type is AUTO
! if it isnt and ON_STEP these rules wont take anyway
!-------------------------------------------
!Do the equivalent of the following:
!READ(input_line, *) on_step_label, eq_label1, on_step, colon_label, var_label, eq_label2, value_str
!Format:
! ON_STEP = on_step : var_label = value_str
!-------------------------------------------
IF( ionode ) write(*,*) 'ADD_RULE: POWER STEERING'
! Attempt to get ON_STEP
on_step = MAX_INT
! if all is non-trivial, read a PLUS_STEP
if ((eq1_pos > 0) .and. (colon_pos > eq1_pos)) then
! assume a number lies between
read(input_line(eq1_pos+1:colon_pos-1),*,iostat=ios) on_step
if(ios .ne. 0) then
CALL auto_error( ' AutoPilot ','Value Type Mismatch on ON_STEP line!')
go to 20
end if
end if
!================================================================================
! set event
!
! Heres where it get interesting
! We may have a new event , or not! :)
IF ( ((event-1) .gt. 0) .and. ( on_step .lt. event_step(event-1)) ) THEN
IF( ionode ) write(*,*) ' AutoPilot: current input_line', input_line
CALL auto_error( ' AutoPilot ','Dynamic Rule Event Out of Order!')
go to 20
ENDIF
IF ( (event .eq. 0) .or. (on_step .gt. event_step(event)) ) THEN
! new event
event = event + 1
IF (event > max_event_step) THEN
IF( ionode ) write(*,*) ' AutoPilot: current input_line', input_line
CALL auto_error( ' AutoPilot ','Maximum Number of Dynamic Rule Event Exceeded!')
go to 20
ENDIF
event_step(event) = on_step
n_events = event
ENDIF
END IF ! Event Detection Complete
!-------------------------------------
! Now look for a label and a value
!-------------------------------------
if (eq2_pos .eq. 0) then
var_label = input_line(colon_pos+1: eq1_pos-1)
read( input_line(eq1_pos+1:linelen), *, iostat=ios) value_str
if(ios .ne. 0) then
CALL auto_error( ' AutoPilot ','Value Type Mismatch on NOW_STEP line!')
go to 20
end if
else
var_label = input_line(colon_pos+1: eq2_pos-1)
read( input_line(eq2_pos+1:linelen), *, iostat=ios) value_str
if(ios .ne. 0) then
CALL auto_error( ' AutoPilot ','Value Type Mismatch on ON_STEP line!')
go to 20
end if
endif
! The Assignment must lie outside the new event scope since
! there can exists more than one rule per event
IF ( (n_rules+1) .gt. max_rules) THEN
IF( ionode ) write(*,*) ' AutoPilot: current n_rules', n_rules
CALL auto_error( ' AutoPilot ', ' invalid number of rules ')
go to 20
END IF
call assign_rule(event, var_label, value_str)
!IF( ionode ) write(*,*) ' Number of rules: ', n_rules
CALL flush_unit(6)
20 CONTINUE
END SUBROUTINE add_rule
!-----------------------------------------------------------------------
! ASSIGN_RULE
!-----------------------------------------------------------------------
SUBROUTINE assign_rule(event, var, value)
USE input_parameters, ONLY : isave, iprint, dt, tempw
USE io_global, ONLY: ionode, ionode_id
IMPLICIT NONE
INTEGER :: i, event, varlen
CHARACTER(LEN=32) :: var
CHARACTER(LEN=32) :: value
INTEGER :: int_value
REAL :: real_value
REAL(DP) :: realDP_value
LOGICAL :: assigned
LOGICAL, EXTERNAL :: matches
CHARACTER(LEN=1), EXTERNAL :: capital
var = TRIM(var)
varlen = LEN_TRIM(var)
DO i = 1, varlen
var( i : i ) = capital( var( i : i ) )
END DO
IF( ionode ) write(*,'(" Reading rule: ",A20,A20)' ) var, value
assigned = .TRUE.
IF ( matches( "ISAVE", var ) ) THEN
read(value, *) int_value
rule_isave(event) = int_value
event_isave(event) = .true.
ELSEIF ( matches( "IPRINT", var ) ) THEN
read(value, *) int_value
rule_iprint(event) = int_value
event_iprint(event) = .true.
ELSEIF ( matches( "DT", var ) ) THEN
read(value, *) real_value
rule_dt(event) = real_value
event_dt(event) = .true.
!IF( ionode ) write(*,*) 'RULE_DT', rule_dt(event), 'EVENT', event
ELSEIF ( matches( "EMASS", var ) ) THEN
read(value, *) realDP_value
rule_emass(event) = realDP_value
event_emass(event) = .true.
ELSEIF ( matches( "ELECTRON_DYNAMICS", var ) ) THEN
read(value, *) value
if ((value .ne. 'SD') .and. (value .ne. 'VERLET') .and. (value .ne. 'DAMP') .and. (value .ne. 'NONE')) then
call auto_error(' autopilot ',' unknown electron_dynamics '//trim(value) )
assigned = .FALSE.
go to 40
endif
rule_electron_dynamics(event) = value
event_electron_dynamics(event) = .true.
ELSEIF ( matches( "ELECTRON_DAMPING", var ) ) THEN
read(value, *) realDP_value
rule_electron_damping(event) = realDP_value
event_electron_damping(event) = .true.
ELSEIF ( matches( "ION_DYNAMICS", var ) ) THEN
read(value, *) value
if ((value .ne. 'SD') .and. (value .ne. 'VERLET') .and. (value .ne. 'DAMP') .and. (value .ne. 'NONE')) then
call auto_error(' autopilot ',' unknown ion_dynamics '//trim(value) )
assigned = .FALSE.
go to 40
endif
rule_ion_dynamics(event) = value
event_ion_dynamics(event) = .true.
ELSEIF ( matches( "ION_DAMPING", var ) ) THEN
read(value, *) realDP_value
rule_ion_damping(event) = realDP_value
event_ion_damping(event) = .true.
ELSEIF ( matches( "ION_TEMPERATURE", var ) ) THEN
read(value, *) value
if ((value .ne. 'NOSE') .and. (value .ne. 'NOT_CONTROLLED') .and. (value .ne. 'RESCALING')) then
call auto_error(' autopilot ',' unknown ion_temperature '//trim(value) )
assigned = .FALSE.
go to 40
endif
rule_ion_temperature(event) = value
event_ion_temperature(event) = .true.
ELSEIF ( matches( "TEMPW", var ) ) THEN
read(value, *) realDP_value
rule_tempw(event) = realDP_value
event_tempw(event) = .true.
ELSE
CALL auto_error( 'autopilot', ' ASSIGN_RULE: FAILED '//trim(var)//' '//trim(value) )
END IF
40 if (assigned) then
n_rules = n_rules + 1
else
IF( ionode ) write(*,*) ' Autopilot: Rule Assignment Failure '
CALL auto_error( 'autopilot', ' ASSIGN_RULE: FAILED '//trim(var)//' '//trim(value) )
endif
END SUBROUTINE assign_rule
!-----------------------------------------------------------------------
! PARSE_MAILBOX
!
! Read the mailbox with a mailbox parser
! if it starts with ON_STEP, then apply to event table etc
! if not the try to establish that its a variable to set right now
!-----------------------------------------------------------------------
SUBROUTINE parse_mailbox ()
USE io_global, ONLY: ionode, ionode_id
USE mp, ONLY : mp_bcast, mp_barrier
USE mp_world, ONLY : world_comm
IMPLICIT NONE
INTEGER :: i
CHARACTER(LEN=256) :: input_line
LOGICAL :: tend
CHARACTER(LEN=1), EXTERNAL :: capital
LOGICAL, EXTERNAL :: matches
! we can use this parser routine, since parse_unit=pilot_unit
CALL read_line( input_line, end_of_file=tend )
IF (tend) GO TO 50
DO i = 1, LEN_TRIM( input_line )
input_line( i : i ) = capital( input_line( i : i ) )
END DO
! This conditional implements the PAUSE feature calling init_auto_pilot,
! will reset this modules global PAUSE_P variable to FALSE
IF ( matches( "PAUSE", input_line ) .or. &
matches( "SLEEP", input_line ) .or. &
matches( "HOVER", input_line ) .or. &
matches( "WAIT", input_line ) .or. &
matches( "HOLD", input_line ) ) THEN
IF( ionode ) write(*,*) 'SLEEPING'
IF( ionode ) write(*,*) 'INPUT_LINE=', input_line
pause_p = .TRUE.
! now you can pass continue to resume
ELSE IF (matches( "CONTINUE", input_line ) .or. &
matches( "RESUME", input_line ) ) THEN
IF( ionode ) write(*,*) 'RUNNING'
IF( ionode ) write(*,*) 'INPUT_LINE=', input_line
pause_p = .FALSE.
! Now just quit this subroutine
ELSE
! Also, We didnt see a PAUSE cmd!
pause_p = .FALSE.
! now lets detect the mode for card_autopilot
! even though this line will be passed to it the first time
IF ( matches( "AUTOPILOT", TRIM(input_line) ) ) THEN
IF( ionode ) WRITE(*,*) ' New autopilot course detected'
pilot_type ='AUTO'
ELSE IF (matches( "PILOT", TRIM(input_line) ) ) THEN
IF( ionode ) WRITE(*,*) ' Relative pilot course correction detected'
pilot_type ='PILOT'
ELSE IF (matches( "NOW", TRIM(input_line) ) ) THEN
IF( ionode ) WRITE(*,*) ' Manual piloting detected'
pilot_type ='MANUAL'
ELSE
! Well lets just pause since this guys is throwing trash
IF( ionode ) WRITE(*,*) ' Mailbox contents not understood: pausing'
pause_p = .TRUE.
ENDIF
END IF
IF (pause_p) GO TO 50
! ok if one adds a rule during steering`
! event table must be cleared (from steer point) forward
!
! Every nodes gets this (and the call to card_autopilot
! which calls add_rule, which calls assign_rule, etc
! In this way we sync the event table
! Then we shouldn't have to sync employ_rules variable
! changes, or their subroutine side effects (like ions_nose_init)
CALL init_autopilot()
CALL card_autopilot( input_line )
50 CONTINUE
end subroutine parse_mailbox
END MODULE autopilot
|