1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72
|
<!doctype html>
<title>WebSockets : Boundary-value tests for the 'Extended payload length' field in RFC6455 section5.2 'Base Framing Protocol'</title>
<meta name=timeout content=long>
<script src=/resources/testharness.js></script>
<script src=/resources/testharnessreport.js></script>
<script src=constants.sub.js></script>
<meta name="variant" content="?default">
<meta name="variant" content="?wss">
<meta name="variant" content="?wpt_flags=h2">
<div id=log></div>
<script>
async_test(function(t){
var ws = new WebSocket(SCHEME_DOMAIN_PORT+'/echo');
var datasize = 125;
var data = null;
ws.onopen = t.step_func(function(e) {
data = new Array(datasize + 1).join('a');
ws.send(data);
});
ws.onmessage = t.step_func(function(e) {
assert_equals(e.data, data);
t.done();
});
ws.onclose = t.unreached_func('close event should not fire');
}, "Application data is 125 byte which means any 'Extended payload length' field isn't used at all.");
async_test(function(t){
var ws = new WebSocket(SCHEME_DOMAIN_PORT+'/echo');
var datasize = 126;
var data = null;
ws.onopen = t.step_func(function(e) {
data = new Array(datasize + 1).join('a');
ws.send(data);
});
ws.onmessage = t.step_func(function(e) {
assert_equals(e.data, data);
t.done();
});
ws.onclose = t.unreached_func('close event should not fire');
}, "Application data is 126 byte which starts to use the 16 bit 'Extended payload length' field.");
async_test(function(t){
var ws = new WebSocket(SCHEME_DOMAIN_PORT+'/echo');
var datasize = 0xFFFF;
var data = null;
ws.onopen = t.step_func(function(e) {
data = new Array(datasize + 1).join('a');
ws.send(data);
});
ws.onmessage = t.step_func(function(e) {
assert_equals(e.data, data);
t.done();
});
ws.onclose = t.unreached_func('close event should not fire');
}, "Application data is 0xFFFF byte which means the upper bound of the 16 bit 'Extended payload length' field.");
async_test(function(t){
var ws = new WebSocket(SCHEME_DOMAIN_PORT+'/echo');
var datasize = 0xFFFF + 1;
var data = null;
ws.onopen = t.step_func(function(e) {
data = new Array(datasize + 1).join('a');
ws.send(data);
});
ws.onmessage = t.step_func(function(e) {
assert_equals(e.data, data);
t.done();
});
ws.onclose = t.unreached_func('close event should not fire');
}, "Application data is (0xFFFF + 1) byte which starts to use the 64 bit 'Extended payload length' field");
</script>
|