1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128
|
Usage: scanimage [OPTION]...
Start image acquisition on a scanner device and write PNM image data to
standard output.
-d, --device-name=DEVICE use a given scanner device (e.g. hp:/dev/scanner)
--format=pnm|tiff file format of output file
-i, --icc-profile=PROFILE include this ICC profile into TIFF file
-L, --list-devices show available scanner devices
-f, --formatted-device-list=FORMAT similar to -L, but the FORMAT of the output
can be specified: %d (device name), %v (vendor),
%m (model), %t (type), and %i (index number)
-b, --batch[=FORMAT] working in batch mode, FORMAT is `out%d.pnm' or
`out%d.tif' by default depending on --format
--batch-start=# page number to start naming files with
--batch-count=# how many pages to scan in batch mode
--batch-increment=# increase number in filename by an amount of #
--batch-double increment page number by two for 2sided originals
being scanned in a single sided scanner
--batch-prompt ask for pressing a key before scanning a page
--accept-md5-only only accept authorization requests using md5
-p, --progress print progress messages
-n, --dont-scan only set options, don't actually scan
-T, --test test backend thoroughly
-h, --help display this help message and exit
-v, --verbose give even more status messages
-B, --buffer-size change default input buffersize
-V, --version print version information
Options specific to device `net:esche:epson:libusb:001:006':
Scan Mode:
--mode Binary|Gray|Color [Binary]
Selects the scan mode (e.g., lineart, monochrome, or color).
--depth 8 [inactive]
Number of bits per sample, typical values are 1 for "line-art" and 8
for multibit scans.
--halftoning None|Halftone A (Hard Tone)|Halftone B (Soft Tone)|Halftone C (Net Screen)|Dither A (4x4 Bayer)|Dither B (4x4 Spiral)|Dither C (4x4 Net Screen)|Dither D (8x4 Net Screen)|Text Enhanced Technology|Download pattern A|Download pattern B [Halftone A (Hard Tone)]
Selects the halftone.
--dropout None|Red|Green|Blue [None]
Selects the dropout.
--brightness -4..3 [0]
Selects the brightness.
--sharpness -2..2 [0]
--gamma-correction Default|User defined|High density printing|Low density printing|High contrast printing [Default]
Selects the gamma correction value from a list of pre-defined devices
or the user defined table, which can be downloaded to the scanner
--color-correction No Correction|User defined|Impact-dot printers|Thermal printers|Ink-jet printers|CRT monitors [CRT monitors]
Sets the color correction table for the selected output device.
--resolution 50|60|72|75|80|90|100|120|133|144|150|160|175|180|200|216|240|266|300|320|350|360|400|480|600|720|800|900|1200|1600|1800|2400dpi [50]
Sets the resolution of the scanned image.
--threshold 0..255 [128]
Select minimum-brightness to get a white point
Advanced:
--mirror[=(yes|no)] [no]
Mirror the image.
--speed[=(yes|no)] [no]
Determines the speed at which the scan proceeds.
--auto-area-segmentation[=(yes|no)] [yes]
--short-resolution[=(yes|no)] [no]
Display short resolution list
--zoom 50..200 [inactive]
Defines the zoom factor the scanner will use
--red-gamma-table 0..255,... [inactive]
Gamma-correction table for the red band.
--green-gamma-table 0..255,... [inactive]
Gamma-correction table for the green band.
--blue-gamma-table 0..255,... [inactive]
Gamma-correction table for the blue band.
--wait-for-button[=(yes|no)] [no]
After sending the scan command, wait until the button on the scanner
is pressed to actually start the scan process.
Color correction coefficients:
--cct-1 -127..127 [inactive]
Controls green level
--cct-2 -127..127 [inactive]
Adds to red based on green level
--cct-3 -127..127 [inactive]
Adds to blue based on green level
--cct-4 -127..127 [inactive]
Adds to green based on red level
--cct-5 -127..127 [inactive]
Controls red level
--cct-6 -127..127 [inactive]
Adds to blue based on red level
--cct-7 -127..127 [inactive]
Adds to green based on blue level
--cct-8 -127..127 [inactive]
Adds to red based on blue level
--cct-9 -127..127 [inactive]
Controls blue level
Preview:
--preview[=(yes|no)] [no]
Request a preview-quality scan.
--preview-speed[=(yes|no)] [no]
Geometry:
-l 0..215.9mm [0]
Top-left x position of scan area.
-t 0..297.18mm [0]
Top-left y position of scan area.
-x 0..215.9mm [215.9]
Width of scan-area.
-y 0..297.18mm [297.18]
Height of scan-area.
--quick-format CD|A5 portrait|A5 landscape|Letter|A4|Max [Max]
Optional equipment:
--source Flatbed [inactive]
Selects the scan source (such as a document-feeder).
--auto-eject[=(yes|no)] [inactive]
Eject document after scanning
--film-type Positive Film|Negative Film [inactive]
--focus-position Focus on glass|Focus 2.5mm above glass [inactive]
Sets the focus position to either the glass or 2.5mm above the glass
--bay 1 | 2 | 3 | 4 | 5 | 6 [inactive]
Select bay to scan
--eject [inactive]
Eject the sheet in the ADF
--adf_mode Simplex|Duplex [inactive]
Selects the ADF mode (simplex/duplex)
Type ``scanimage --help -d DEVICE'' to get list of all options for DEVICE.
List of available devices:
net:esche:epson:libusb:001:006
|