File: epson1200

package info (click to toggle)
gscan2pdf 1.2.6-1
  • links: PTS, VCS
  • area: main
  • in suites: jessie, jessie-kfreebsd
  • size: 3,560 kB
  • ctags: 445
  • sloc: perl: 16,714; xml: 32; makefile: 5
file content (128 lines) | stat: -rw-r--r-- 5,839 bytes parent folder | download | duplicates (8)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
Usage: scanimage [OPTION]...

Start image acquisition on a scanner device and write PNM image data to
standard output.

-d, --device-name=DEVICE   use a given scanner device (e.g. hp:/dev/scanner)
    --format=pnm|tiff      file format of output file
-i, --icc-profile=PROFILE  include this ICC profile into TIFF file
-L, --list-devices         show available scanner devices
-f, --formatted-device-list=FORMAT similar to -L, but the FORMAT of the output
                           can be specified: %d (device name), %v (vendor),
                           %m (model), %t (type), and %i (index number)
-b, --batch[=FORMAT]       working in batch mode, FORMAT is `out%d.pnm' or
                           `out%d.tif' by default depending on --format
    --batch-start=#        page number to start naming files with
    --batch-count=#        how many pages to scan in batch mode
    --batch-increment=#    increase number in filename by an amount of #
    --batch-double         increment page number by two for 2sided originals
                           being scanned in a single sided scanner
    --batch-prompt         ask for pressing a key before scanning a page
    --accept-md5-only      only accept authorization requests using md5
-p, --progress             print progress messages
-n, --dont-scan            only set options, don't actually scan
-T, --test                 test backend thoroughly
-h, --help                 display this help message and exit
-v, --verbose              give even more status messages
-B, --buffer-size          change default input buffersize
-V, --version              print version information

Options specific to device `net:esche:epson:libusb:001:006':
  Scan Mode:
    --mode Binary|Gray|Color [Binary]
        Selects the scan mode (e.g., lineart, monochrome, or color).
    --depth 8 [inactive]
        Number of bits per sample, typical values are 1 for "line-art" and 8
        for multibit scans.
    --halftoning None|Halftone A (Hard Tone)|Halftone B (Soft Tone)|Halftone C (Net Screen)|Dither A (4x4 Bayer)|Dither B (4x4 Spiral)|Dither C (4x4 Net Screen)|Dither D (8x4 Net Screen)|Text Enhanced Technology|Download pattern A|Download pattern B [Halftone A (Hard Tone)]
        Selects the halftone.
    --dropout None|Red|Green|Blue [None]
        Selects the dropout.
    --brightness -4..3 [0]
        Selects the brightness.
    --sharpness -2..2 [0]

    --gamma-correction Default|User defined|High density printing|Low density printing|High contrast printing [Default]
        Selects the gamma correction value from a list of pre-defined devices
        or the user defined table, which can be downloaded to the scanner
    --color-correction No Correction|User defined|Impact-dot printers|Thermal printers|Ink-jet printers|CRT monitors [CRT monitors]
        Sets the color correction table for the selected output device.
    --resolution 50|60|72|75|80|90|100|120|133|144|150|160|175|180|200|216|240|266|300|320|350|360|400|480|600|720|800|900|1200|1600|1800|2400dpi [50]
        Sets the resolution of the scanned image.
    --threshold 0..255 [128]
        Select minimum-brightness to get a white point
  Advanced:
    --mirror[=(yes|no)] [no]
        Mirror the image.
    --speed[=(yes|no)] [no]
        Determines the speed at which the scan proceeds.
    --auto-area-segmentation[=(yes|no)] [yes]

    --short-resolution[=(yes|no)] [no]
        Display short resolution list
    --zoom 50..200 [inactive]
        Defines the zoom factor the scanner will use
    --red-gamma-table 0..255,... [inactive]
        Gamma-correction table for the red band.
    --green-gamma-table 0..255,... [inactive]
        Gamma-correction table for the green band.
    --blue-gamma-table 0..255,... [inactive]
        Gamma-correction table for the blue band.
    --wait-for-button[=(yes|no)] [no]
        After sending the scan command, wait until the button on the scanner
        is pressed to actually start the scan process.
  Color correction coefficients:
    --cct-1 -127..127 [inactive]
        Controls green level
    --cct-2 -127..127 [inactive]
        Adds to red based on green level
    --cct-3 -127..127 [inactive]
        Adds to blue based on green level
    --cct-4 -127..127 [inactive]
        Adds to green based on red level
    --cct-5 -127..127 [inactive]
        Controls red level
    --cct-6 -127..127 [inactive]
        Adds to blue based on red level
    --cct-7 -127..127 [inactive]
        Adds to green based on blue level
    --cct-8 -127..127 [inactive]
        Adds to red based on blue level
    --cct-9 -127..127 [inactive]
        Controls blue level
  Preview:
    --preview[=(yes|no)] [no]
        Request a preview-quality scan.
    --preview-speed[=(yes|no)] [no]

  Geometry:
    -l 0..215.9mm [0]
        Top-left x position of scan area.
    -t 0..297.18mm [0]
        Top-left y position of scan area.
    -x 0..215.9mm [215.9]
        Width of scan-area.
    -y 0..297.18mm [297.18]
        Height of scan-area.
    --quick-format CD|A5 portrait|A5 landscape|Letter|A4|Max [Max]

  Optional equipment:
    --source Flatbed [inactive]
        Selects the scan source (such as a document-feeder).
    --auto-eject[=(yes|no)] [inactive]
        Eject document after scanning
    --film-type Positive Film|Negative Film [inactive]

    --focus-position Focus on glass|Focus 2.5mm above glass [inactive]
        Sets the focus position to either the glass or 2.5mm above the glass
    --bay  1 | 2 | 3 | 4 | 5 | 6  [inactive]
        Select bay to scan
    --eject [inactive]
        Eject the sheet in the ADF
    --adf_mode Simplex|Duplex [inactive]
        Selects the ADF mode (simplex/duplex)

Type ``scanimage --help -d DEVICE'' to get list of all options for DEVICE.

List of available devices:
    net:esche:epson:libusb:001:006