1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
|
:: RESTful Interface Tool Sample Script for HPE iLO Products ::
:: Copyright 2014, 2020 Hewlett Packard Enterprise Development LP ::
:: Description: This is a sample batch script to update the ::
:: Integrated Lights-Out(iLO) firmware. ::
:: NOTE: You will need to replace the USER_LOGIN and PASSWORD ::
:: values with values that are appropriate for your ::
:: environment and you will need to change the value of the ::
:: IMAGE_LOCATION to point to the new binary firmware image ::
:: you wish to use for the firmware update. ::
:: The Unit ID light flashes when the server is engaged in ::
:: an activity that can not or should not be interrupted ::
:: (such as updating iLO firmware or an active Remote ::
:: Console session). The Unit ID light should flash while ::
:: this script is updating the firmware. ::
:: The Lights-Out device will automatically reset itself to ::
:: have the new firmware take effect at the end of the ::
:: firmware flash. ::
:: Firmware support information for this script: ::
:: iLO 5 - All versions ::
:: iLO 4 - All versions ::
@echo off
set argC=0
for %%x in (%*) do Set /A argC+=1
if %argC% EQU 3 goto :remote
if %argC% EQU 0 goto :local
goto :error
:local
ilorest login -u USER_LOGIN -p PASSWORD
ilorest firmwareupdate https://IMAGE_LOCATION.bin
:: Use the line below instead if your server uses TPM: ::
::ilorest firmwareupdate https://IMAGE_LOCATION.bin --tpmenabled -u USER_LOGIN -p PASSWORD ::
ilorest logout
goto :exit
:remote
ilorest login %1 -u %2 -p %3
ilorest firmwareupdate https://IMAGE_LOCATION.bin
:: Use the line below instead if your server uses TPM: ::
::ilorest firmwareupdate https://IMAGE_LOCATION.bin --tpmenabled --url=%1 -u %2 -p %3 ::
ilorest logout
goto :exit
:error
echo Usage:
echo remote: Update_Firmware.bat ^<iLO url^> ^<iLO username^> ^<iLO password^>
echo local: Update_Firmware.bat
:exit
|