1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2876 2877 2878 2879 2880 2881 2882 2883 2884 2885 2886 2887 2888 2889 2890 2891 2892 2893 2894 2895 2896 2897 2898 2899 2900 2901 2902 2903 2904 2905 2906 2907 2908 2909 2910 2911 2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923 2924 2925 2926 2927 2928 2929 2930 2931 2932 2933 2934 2935 2936 2937 2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981 2982 2983 2984 2985 2986 2987 2988 2989 2990 2991 2992 2993 2994 2995 2996 2997 2998 2999 3000 3001 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3013 3014 3015 3016 3017 3018 3019 3020 3021 3022 3023 3024 3025 3026 3027 3028 3029 3030 3031 3032 3033 3034 3035 3036 3037 3038 3039 3040 3041 3042 3043 3044 3045 3046 3047 3048 3049 3050 3051 3052 3053 3054 3055 3056 3057 3058 3059 3060 3061 3062 3063 3064 3065 3066 3067 3068 3069 3070 3071 3072 3073 3074 3075 3076 3077 3078 3079 3080 3081 3082 3083 3084 3085 3086 3087 3088 3089 3090 3091 3092 3093 3094 3095 3096 3097 3098 3099 3100 3101 3102 3103 3104 3105 3106 3107 3108 3109 3110 3111 3112 3113 3114 3115 3116 3117 3118 3119 3120 3121 3122 3123 3124 3125 3126 3127 3128 3129 3130 3131 3132 3133 3134 3135 3136 3137 3138 3139 3140 3141 3142 3143 3144 3145 3146 3147 3148 3149 3150 3151 3152 3153 3154 3155 3156 3157 3158 3159 3160 3161 3162 3163 3164 3165 3166 3167 3168 3169 3170 3171 3172 3173 3174 3175 3176 3177 3178 3179 3180 3181 3182 3183 3184 3185 3186 3187 3188 3189 3190 3191 3192 3193 3194 3195 3196 3197 3198 3199 3200 3201 3202 3203 3204 3205 3206 3207 3208 3209 3210 3211 3212 3213 3214 3215 3216 3217 3218 3219 3220 3221 3222 3223 3224 3225 3226 3227 3228 3229 3230 3231 3232 3233 3234 3235 3236 3237 3238 3239 3240 3241 3242 3243 3244 3245 3246 3247 3248 3249 3250 3251 3252 3253 3254 3255 3256 3257 3258 3259 3260 3261 3262 3263 3264 3265 3266 3267 3268 3269 3270 3271 3272 3273 3274 3275 3276 3277 3278 3279 3280 3281 3282 3283 3284 3285 3286 3287 3288 3289 3290 3291 3292 3293 3294 3295 3296 3297 3298 3299 3300 3301 3302 3303 3304 3305 3306 3307 3308 3309 3310 3311 3312 3313 3314 3315 3316 3317 3318 3319 3320 3321 3322 3323 3324 3325 3326 3327 3328 3329 3330 3331 3332 3333 3334 3335 3336 3337 3338 3339 3340 3341 3342 3343 3344 3345 3346 3347 3348 3349 3350 3351 3352 3353 3354 3355 3356 3357 3358 3359 3360 3361 3362 3363 3364 3365 3366 3367 3368 3369 3370 3371 3372 3373 3374 3375 3376 3377 3378 3379 3380 3381 3382 3383 3384 3385 3386 3387 3388 3389 3390 3391 3392 3393 3394 3395 3396 3397 3398 3399 3400 3401 3402 3403 3404 3405 3406 3407 3408 3409 3410 3411 3412 3413 3414 3415 3416 3417 3418 3419 3420 3421 3422 3423 3424 3425 3426 3427 3428 3429 3430 3431 3432 3433 3434 3435 3436 3437 3438 3439 3440 3441 3442 3443 3444 3445 3446 3447 3448 3449 3450 3451 3452 3453 3454 3455 3456 3457 3458 3459 3460 3461 3462 3463 3464 3465 3466 3467 3468 3469 3470 3471 3472 3473 3474 3475 3476 3477 3478 3479 3480 3481 3482 3483 3484 3485 3486 3487 3488 3489 3490 3491 3492 3493 3494 3495 3496 3497 3498 3499 3500 3501 3502 3503 3504 3505 3506 3507 3508 3509 3510 3511 3512 3513 3514 3515 3516 3517 3518 3519 3520 3521 3522 3523 3524 3525 3526 3527 3528 3529 3530 3531 3532 3533 3534 3535 3536 3537 3538 3539 3540 3541 3542 3543 3544 3545 3546 3547 3548 3549 3550 3551 3552 3553 3554 3555 3556 3557 3558 3559 3560 3561 3562 3563 3564 3565 3566 3567 3568 3569 3570 3571 3572 3573 3574 3575 3576 3577 3578 3579 3580 3581 3582 3583 3584 3585 3586 3587 3588 3589 3590 3591 3592 3593 3594 3595 3596 3597 3598 3599 3600 3601 3602 3603 3604 3605 3606 3607 3608 3609 3610 3611 3612 3613 3614 3615 3616 3617 3618 3619 3620 3621 3622 3623 3624 3625 3626 3627 3628 3629 3630 3631 3632 3633 3634 3635 3636 3637 3638 3639 3640 3641 3642 3643 3644 3645 3646 3647 3648 3649 3650 3651 3652 3653 3654 3655 3656 3657 3658 3659 3660 3661 3662 3663 3664 3665 3666 3667 3668 3669 3670 3671 3672 3673 3674 3675 3676 3677 3678 3679 3680 3681 3682 3683 3684 3685 3686 3687 3688 3689 3690 3691 3692 3693 3694 3695 3696 3697 3698 3699 3700 3701 3702 3703 3704 3705 3706 3707 3708 3709 3710 3711 3712 3713 3714 3715 3716 3717 3718 3719 3720 3721 3722 3723 3724 3725 3726 3727 3728 3729 3730 3731 3732 3733 3734 3735 3736 3737 3738 3739 3740 3741 3742 3743 3744 3745 3746 3747 3748 3749 3750 3751 3752 3753 3754 3755 3756 3757 3758 3759 3760 3761 3762 3763 3764 3765 3766 3767 3768 3769 3770 3771 3772 3773 3774 3775 3776 3777 3778 3779 3780 3781 3782 3783 3784 3785 3786 3787 3788 3789 3790 3791 3792 3793 3794 3795 3796 3797 3798 3799 3800 3801 3802 3803 3804 3805 3806 3807 3808 3809 3810 3811 3812 3813 3814 3815 3816 3817 3818 3819 3820 3821 3822 3823 3824 3825 3826 3827 3828 3829 3830 3831 3832 3833 3834 3835 3836 3837 3838 3839 3840 3841 3842 3843 3844 3845 3846 3847 3848 3849 3850 3851 3852 3853 3854 3855 3856 3857 3858 3859 3860 3861 3862 3863 3864 3865 3866 3867 3868 3869 3870 3871 3872 3873 3874 3875 3876 3877 3878 3879 3880 3881 3882 3883 3884 3885 3886 3887 3888 3889 3890 3891 3892 3893 3894 3895 3896 3897 3898 3899 3900 3901 3902 3903 3904 3905 3906 3907 3908 3909 3910 3911 3912 3913 3914 3915 3916 3917 3918 3919 3920 3921 3922 3923 3924 3925 3926 3927 3928 3929 3930 3931 3932 3933 3934 3935 3936 3937 3938 3939 3940 3941 3942 3943 3944 3945 3946 3947 3948 3949 3950 3951 3952 3953 3954 3955 3956 3957 3958 3959 3960 3961 3962 3963 3964 3965 3966 3967 3968 3969 3970 3971 3972 3973 3974 3975 3976 3977 3978 3979 3980 3981 3982 3983 3984 3985 3986 3987 3988 3989 3990 3991 3992 3993 3994 3995 3996 3997 3998 3999 4000 4001 4002 4003 4004 4005 4006 4007 4008 4009 4010 4011 4012 4013 4014 4015 4016 4017 4018 4019 4020 4021 4022 4023 4024 4025 4026 4027 4028 4029 4030 4031 4032 4033 4034 4035 4036 4037 4038 4039 4040 4041 4042 4043 4044 4045 4046 4047 4048 4049 4050 4051 4052 4053 4054 4055 4056 4057 4058 4059 4060 4061 4062 4063 4064 4065 4066 4067 4068 4069 4070 4071 4072 4073 4074 4075 4076 4077 4078 4079 4080 4081 4082 4083 4084 4085 4086 4087 4088 4089 4090 4091 4092 4093 4094 4095 4096 4097 4098 4099 4100 4101 4102 4103 4104 4105 4106 4107 4108 4109 4110 4111 4112 4113 4114 4115 4116 4117 4118 4119 4120 4121 4122 4123 4124 4125 4126 4127 4128 4129 4130 4131 4132 4133 4134 4135 4136 4137 4138 4139 4140 4141 4142 4143 4144 4145 4146 4147 4148 4149 4150 4151 4152 4153 4154 4155 4156 4157 4158 4159 4160 4161 4162 4163 4164 4165 4166 4167 4168 4169 4170 4171 4172 4173 4174 4175 4176 4177 4178 4179 4180 4181 4182 4183 4184 4185 4186 4187 4188 4189 4190 4191 4192 4193 4194 4195 4196 4197 4198 4199 4200 4201 4202 4203 4204 4205 4206 4207 4208 4209 4210 4211 4212 4213 4214 4215 4216 4217 4218 4219 4220 4221 4222 4223 4224 4225 4226 4227 4228 4229 4230 4231 4232 4233 4234 4235 4236 4237 4238 4239 4240 4241 4242 4243 4244 4245 4246 4247 4248 4249 4250 4251 4252 4253 4254 4255 4256 4257 4258 4259 4260 4261 4262 4263 4264 4265 4266 4267 4268 4269 4270 4271 4272 4273 4274 4275 4276 4277 4278 4279 4280 4281 4282 4283 4284 4285 4286 4287 4288 4289 4290 4291 4292 4293 4294 4295 4296 4297 4298 4299 4300 4301 4302 4303 4304 4305 4306 4307 4308 4309 4310 4311 4312 4313 4314 4315 4316 4317 4318 4319 4320 4321 4322 4323 4324 4325 4326 4327 4328 4329 4330 4331 4332 4333 4334 4335 4336 4337 4338 4339 4340 4341 4342 4343 4344 4345 4346 4347 4348 4349 4350 4351 4352 4353 4354 4355 4356 4357 4358 4359 4360 4361 4362 4363 4364 4365 4366 4367 4368 4369 4370 4371 4372 4373 4374 4375 4376 4377 4378 4379 4380 4381 4382 4383 4384 4385 4386 4387 4388 4389 4390 4391 4392 4393 4394 4395 4396 4397 4398 4399 4400 4401 4402 4403 4404 4405 4406 4407 4408 4409 4410 4411 4412 4413 4414 4415 4416 4417 4418 4419 4420 4421 4422 4423 4424 4425 4426 4427 4428 4429 4430 4431 4432 4433 4434 4435 4436 4437 4438 4439 4440 4441 4442 4443 4444 4445 4446 4447 4448 4449 4450 4451 4452 4453 4454 4455 4456 4457 4458 4459 4460 4461 4462 4463 4464 4465 4466 4467 4468 4469 4470 4471 4472 4473 4474 4475 4476 4477 4478 4479 4480 4481 4482 4483 4484 4485 4486 4487 4488 4489 4490 4491 4492 4493 4494 4495 4496 4497 4498 4499 4500 4501 4502 4503 4504 4505 4506 4507 4508 4509 4510 4511 4512 4513 4514 4515 4516 4517 4518 4519 4520 4521 4522 4523 4524 4525 4526 4527 4528 4529 4530 4531 4532 4533 4534 4535 4536 4537 4538 4539 4540 4541 4542 4543 4544 4545 4546 4547 4548 4549 4550 4551 4552 4553 4554 4555 4556 4557 4558 4559 4560 4561 4562 4563 4564 4565 4566 4567 4568 4569 4570 4571 4572 4573 4574 4575 4576 4577 4578 4579 4580 4581 4582 4583 4584 4585 4586 4587 4588 4589 4590 4591 4592 4593 4594 4595 4596 4597 4598 4599 4600 4601 4602 4603 4604 4605 4606 4607 4608 4609 4610 4611 4612 4613 4614 4615 4616 4617 4618 4619 4620 4621 4622 4623 4624 4625 4626 4627 4628 4629 4630 4631 4632 4633 4634 4635 4636 4637 4638 4639 4640 4641 4642 4643 4644 4645 4646 4647 4648 4649 4650 4651 4652 4653 4654 4655 4656 4657 4658 4659 4660 4661 4662 4663 4664 4665 4666 4667 4668 4669 4670 4671 4672 4673 4674 4675 4676 4677 4678 4679 4680 4681 4682 4683 4684 4685 4686 4687 4688 4689 4690 4691 4692 4693 4694 4695 4696 4697 4698 4699 4700 4701 4702 4703 4704 4705 4706 4707 4708 4709 4710 4711 4712 4713 4714 4715 4716 4717 4718 4719 4720 4721 4722 4723 4724 4725 4726 4727 4728 4729 4730 4731 4732 4733 4734 4735 4736 4737 4738 4739 4740 4741 4742 4743 4744 4745 4746 4747 4748 4749 4750 4751 4752 4753 4754 4755 4756 4757 4758 4759 4760 4761 4762 4763 4764 4765 4766 4767 4768 4769 4770 4771 4772 4773 4774 4775 4776 4777 4778 4779 4780 4781 4782 4783 4784 4785 4786 4787 4788 4789 4790 4791 4792 4793 4794 4795 4796 4797 4798 4799 4800 4801 4802 4803 4804 4805 4806 4807 4808 4809 4810 4811 4812 4813 4814 4815 4816 4817 4818 4819 4820 4821 4822 4823 4824 4825 4826 4827 4828 4829 4830 4831 4832 4833 4834 4835 4836 4837 4838 4839 4840 4841 4842 4843 4844 4845 4846 4847 4848 4849 4850 4851 4852 4853 4854 4855 4856 4857 4858 4859 4860 4861 4862 4863 4864 4865 4866 4867 4868 4869 4870 4871 4872 4873 4874 4875 4876 4877 4878 4879 4880 4881 4882 4883 4884 4885 4886 4887 4888 4889 4890 4891 4892 4893 4894 4895 4896 4897 4898 4899 4900 4901 4902 4903 4904 4905 4906 4907 4908 4909 4910 4911 4912 4913 4914 4915 4916 4917 4918 4919 4920 4921 4922 4923 4924 4925 4926 4927 4928 4929 4930 4931 4932 4933 4934 4935 4936 4937 4938 4939 4940 4941 4942 4943 4944 4945 4946 4947 4948 4949 4950 4951 4952 4953 4954 4955 4956 4957 4958 4959 4960 4961 4962 4963 4964 4965 4966 4967 4968 4969 4970 4971 4972 4973 4974 4975 4976 4977 4978 4979 4980 4981 4982 4983 4984 4985 4986 4987 4988 4989 4990 4991 4992 4993 4994 4995 4996 4997 4998 4999 5000 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 5011 5012 5013 5014 5015 5016 5017 5018 5019 5020 5021 5022 5023 5024 5025 5026 5027 5028 5029 5030 5031 5032 5033 5034 5035 5036 5037 5038 5039 5040 5041 5042 5043 5044 5045 5046 5047 5048 5049 5050 5051 5052 5053 5054 5055 5056 5057 5058 5059 5060 5061 5062 5063 5064 5065 5066 5067 5068 5069 5070 5071 5072 5073 5074 5075 5076 5077 5078 5079 5080 5081 5082 5083 5084 5085 5086 5087 5088 5089 5090 5091 5092 5093 5094 5095 5096 5097 5098 5099 5100 5101 5102 5103 5104 5105 5106 5107 5108 5109 5110 5111 5112 5113 5114 5115 5116 5117 5118 5119 5120 5121 5122 5123 5124 5125 5126 5127 5128 5129 5130 5131 5132 5133 5134 5135 5136 5137 5138 5139 5140 5141 5142 5143 5144 5145 5146 5147 5148 5149 5150 5151 5152 5153 5154 5155 5156 5157 5158 5159 5160 5161 5162 5163 5164 5165 5166 5167 5168 5169 5170 5171 5172 5173 5174 5175 5176 5177 5178 5179 5180 5181 5182 5183 5184 5185 5186 5187 5188 5189 5190 5191 5192 5193 5194 5195 5196 5197 5198 5199 5200 5201 5202 5203 5204 5205 5206 5207 5208 5209 5210 5211 5212 5213 5214 5215 5216 5217 5218 5219 5220 5221 5222 5223 5224 5225 5226 5227 5228 5229 5230 5231 5232 5233 5234 5235 5236 5237 5238 5239 5240 5241 5242 5243 5244 5245 5246 5247 5248 5249 5250 5251 5252 5253 5254 5255 5256 5257 5258 5259 5260 5261 5262 5263 5264 5265 5266 5267 5268 5269 5270 5271 5272 5273 5274 5275 5276 5277 5278 5279 5280 5281 5282 5283 5284 5285 5286 5287 5288 5289 5290 5291 5292 5293 5294 5295 5296 5297 5298 5299 5300 5301 5302 5303 5304 5305 5306 5307 5308 5309 5310 5311 5312 5313 5314 5315 5316 5317 5318 5319 5320 5321 5322 5323 5324 5325 5326 5327 5328 5329 5330 5331 5332 5333 5334 5335 5336 5337 5338 5339 5340 5341 5342 5343 5344 5345 5346 5347 5348 5349 5350 5351 5352 5353 5354 5355 5356 5357 5358 5359 5360 5361 5362 5363 5364 5365 5366 5367 5368 5369 5370 5371 5372 5373 5374 5375 5376 5377 5378 5379 5380 5381 5382 5383 5384 5385 5386 5387 5388 5389 5390 5391 5392 5393 5394 5395 5396 5397 5398 5399 5400 5401 5402 5403 5404 5405 5406 5407 5408 5409 5410 5411 5412 5413 5414 5415 5416 5417 5418 5419 5420 5421 5422 5423 5424 5425 5426 5427 5428 5429 5430 5431 5432 5433 5434 5435 5436 5437 5438 5439 5440 5441 5442 5443 5444 5445 5446 5447 5448 5449 5450 5451 5452 5453 5454 5455 5456 5457 5458 5459 5460 5461 5462 5463 5464 5465 5466 5467 5468 5469 5470 5471 5472 5473 5474 5475 5476 5477 5478 5479 5480 5481 5482 5483 5484 5485 5486 5487 5488 5489 5490 5491 5492 5493 5494 5495 5496 5497 5498 5499 5500 5501 5502 5503 5504 5505 5506 5507 5508 5509 5510 5511 5512 5513 5514 5515 5516 5517 5518 5519 5520 5521 5522 5523 5524 5525 5526 5527 5528 5529 5530 5531 5532 5533 5534 5535 5536 5537 5538 5539 5540 5541 5542 5543 5544 5545 5546 5547 5548 5549 5550 5551 5552 5553 5554 5555 5556 5557 5558 5559 5560 5561 5562 5563 5564 5565 5566 5567 5568 5569 5570 5571 5572 5573 5574 5575 5576 5577 5578 5579 5580 5581 5582 5583 5584 5585 5586 5587 5588 5589 5590 5591 5592 5593 5594 5595 5596 5597 5598 5599 5600 5601 5602 5603 5604 5605 5606 5607 5608 5609 5610 5611 5612 5613 5614 5615 5616 5617 5618 5619 5620 5621 5622 5623 5624 5625 5626 5627 5628 5629 5630 5631 5632 5633 5634 5635 5636 5637 5638 5639 5640 5641 5642 5643 5644 5645 5646 5647 5648 5649 5650 5651 5652 5653 5654 5655 5656 5657 5658 5659 5660 5661 5662 5663 5664 5665 5666 5667 5668 5669 5670 5671 5672 5673 5674 5675 5676 5677 5678 5679 5680 5681 5682 5683 5684 5685 5686 5687 5688 5689 5690 5691 5692 5693 5694 5695 5696 5697 5698 5699 5700 5701 5702 5703 5704 5705 5706 5707 5708 5709 5710 5711 5712 5713 5714 5715 5716 5717 5718 5719 5720 5721 5722 5723 5724 5725 5726 5727 5728 5729 5730 5731 5732 5733 5734 5735 5736 5737 5738 5739 5740 5741 5742 5743 5744 5745 5746 5747 5748 5749 5750 5751 5752 5753 5754 5755 5756 5757 5758 5759 5760 5761 5762 5763 5764 5765 5766 5767 5768 5769 5770 5771 5772 5773 5774 5775 5776 5777 5778 5779 5780 5781 5782 5783 5784 5785 5786 5787 5788 5789 5790 5791 5792 5793 5794 5795 5796 5797 5798 5799 5800 5801 5802 5803 5804 5805 5806 5807 5808 5809 5810 5811 5812 5813 5814 5815 5816 5817 5818 5819 5820 5821 5822 5823 5824 5825 5826 5827 5828 5829 5830 5831 5832 5833 5834 5835 5836 5837 5838 5839 5840 5841 5842 5843 5844 5845 5846 5847 5848 5849 5850 5851 5852 5853 5854 5855 5856 5857 5858 5859 5860 5861 5862 5863 5864 5865 5866 5867 5868 5869 5870 5871 5872 5873 5874 5875 5876 5877 5878 5879 5880 5881 5882 5883 5884 5885 5886 5887 5888 5889 5890 5891 5892 5893 5894 5895 5896 5897 5898 5899 5900 5901 5902 5903 5904 5905 5906 5907 5908 5909 5910 5911 5912 5913 5914 5915 5916 5917 5918 5919 5920 5921 5922 5923 5924 5925 5926 5927 5928 5929 5930 5931 5932 5933 5934 5935 5936 5937 5938 5939 5940 5941 5942 5943 5944 5945 5946 5947 5948 5949 5950 5951 5952 5953 5954 5955 5956 5957 5958 5959 5960 5961 5962 5963 5964 5965 5966 5967 5968 5969 5970 5971 5972 5973 5974 5975 5976 5977 5978 5979 5980 5981 5982 5983 5984 5985 5986 5987 5988 5989 5990 5991 5992 5993 5994 5995 5996 5997 5998 5999 6000 6001 6002 6003 6004 6005 6006 6007 6008 6009 6010 6011 6012 6013 6014 6015 6016 6017 6018 6019 6020 6021 6022 6023 6024 6025 6026 6027 6028 6029 6030 6031 6032 6033 6034 6035 6036 6037 6038 6039 6040 6041 6042 6043 6044 6045 6046 6047 6048 6049 6050 6051 6052 6053 6054 6055 6056 6057 6058 6059 6060 6061 6062 6063 6064 6065 6066 6067 6068 6069 6070 6071 6072 6073 6074 6075 6076 6077 6078 6079 6080 6081 6082 6083 6084 6085 6086 6087 6088 6089 6090 6091 6092 6093 6094 6095 6096 6097 6098 6099 6100 6101 6102 6103 6104 6105 6106 6107 6108 6109 6110 6111 6112 6113 6114 6115 6116 6117 6118 6119 6120 6121 6122 6123 6124 6125 6126 6127 6128 6129 6130 6131 6132 6133 6134 6135 6136 6137 6138 6139 6140 6141 6142 6143 6144 6145 6146 6147 6148 6149 6150 6151 6152 6153 6154 6155 6156 6157 6158 6159 6160 6161 6162 6163 6164 6165 6166 6167 6168 6169 6170 6171 6172 6173 6174 6175 6176 6177 6178 6179 6180 6181 6182 6183 6184 6185 6186 6187 6188 6189 6190 6191 6192 6193 6194 6195 6196 6197 6198 6199 6200 6201 6202 6203 6204 6205 6206 6207 6208 6209 6210 6211 6212 6213 6214 6215 6216 6217 6218 6219 6220 6221 6222 6223 6224 6225 6226 6227 6228 6229 6230 6231 6232 6233 6234 6235 6236 6237 6238 6239 6240 6241 6242 6243 6244 6245 6246 6247 6248 6249 6250 6251 6252 6253 6254 6255 6256 6257 6258 6259 6260 6261 6262 6263 6264 6265 6266 6267 6268 6269 6270 6271 6272 6273 6274 6275 6276 6277 6278 6279 6280 6281 6282 6283 6284 6285 6286 6287 6288 6289 6290 6291 6292 6293 6294 6295 6296 6297 6298 6299 6300 6301 6302 6303 6304 6305 6306 6307 6308 6309 6310 6311 6312 6313 6314 6315 6316 6317 6318 6319 6320 6321 6322 6323 6324 6325 6326 6327 6328 6329 6330 6331 6332 6333 6334 6335 6336 6337 6338 6339 6340 6341 6342 6343 6344 6345 6346 6347 6348 6349 6350 6351 6352 6353 6354 6355 6356 6357 6358 6359 6360 6361 6362 6363 6364 6365 6366 6367 6368 6369 6370 6371 6372 6373 6374 6375 6376 6377 6378 6379 6380 6381 6382 6383 6384 6385 6386 6387 6388 6389 6390 6391 6392 6393 6394 6395 6396 6397 6398 6399 6400 6401 6402 6403 6404 6405 6406 6407 6408 6409 6410 6411 6412 6413 6414 6415 6416 6417 6418 6419 6420 6421 6422 6423 6424 6425 6426 6427 6428 6429 6430 6431 6432 6433 6434 6435 6436 6437 6438 6439 6440 6441 6442 6443 6444 6445 6446 6447 6448 6449 6450 6451 6452 6453 6454 6455 6456 6457 6458 6459 6460 6461 6462 6463 6464 6465 6466 6467 6468 6469 6470 6471 6472 6473 6474 6475 6476 6477 6478 6479 6480 6481 6482 6483 6484 6485 6486 6487 6488 6489 6490 6491 6492 6493 6494 6495 6496 6497 6498 6499 6500 6501 6502 6503 6504 6505 6506 6507 6508 6509 6510 6511 6512 6513 6514 6515 6516 6517 6518 6519 6520 6521 6522 6523 6524 6525 6526 6527 6528 6529 6530 6531 6532 6533 6534 6535 6536 6537 6538 6539 6540 6541 6542 6543 6544 6545 6546 6547 6548 6549 6550 6551 6552 6553 6554 6555 6556 6557 6558 6559 6560 6561 6562 6563 6564 6565 6566 6567 6568 6569 6570 6571 6572 6573 6574 6575 6576 6577 6578 6579 6580 6581 6582 6583 6584 6585 6586 6587 6588 6589 6590 6591 6592 6593 6594 6595 6596 6597 6598 6599 6600 6601 6602 6603 6604 6605 6606 6607 6608 6609 6610 6611 6612 6613 6614 6615 6616 6617 6618 6619 6620 6621 6622 6623 6624 6625 6626 6627 6628 6629 6630 6631 6632 6633 6634 6635 6636 6637 6638 6639 6640 6641 6642 6643 6644 6645 6646 6647 6648 6649 6650 6651 6652 6653 6654 6655 6656 6657 6658 6659 6660 6661 6662 6663 6664 6665 6666 6667 6668 6669 6670 6671 6672 6673 6674 6675 6676 6677 6678 6679 6680 6681 6682 6683 6684 6685 6686 6687 6688 6689 6690 6691 6692 6693 6694 6695
|
IPMIUTIL USER GUIDE
VERSION 3.2.1
An easy-to-use IPMI server management utility
------------------------
CONTENTS
------------------------
1.0 Overview
1.1 Features
2.0 Dependencies
2.1 Configuration
2.2 References
3.0 Utility Man Pages
3.1 IPMIUTIL (ipmiutil)
3.2 IALARMS (ipmiutil alarms)
3.3 ICMD (ipmiutil cmd)
3.4 ICONFIG (ipmiutil config)
3.5 IDISCOVER (ipmiutil discover)
3.6 IEVENTS (ipmiutil events)
3.7 IFRU (ipmiutil fru)
3.8 IGETEVENT (ipmiutil getevt)
3.9 IHEALTH (ipmiutil health)
3.10 ILAN (ipmiutil lan)
3.11 IRESET (ipmiutil reset)
3.12 ISEL (ipmiutil sel)
3.13 ISENSOR (ipmiutil sensor)
3.14 ISERIAL (ipmiutil serial)
3.15 ISOL (ipmiutil sol)
3.16 IWDT (ipmiutil wdt)
3.17 IFRUSET (ifruset)
3.18 IPMI_PORT (ipmi_port)
3.19 IPICMG (ipmiutil picmg)
3.20 IFIREWALL (ipmiutil ifirewall)
3.21 IFWUM (ipmiutil fwum)
3.22 IHPM (ipmiutil hpm)
3.23 ISUNOEM (ipmiutil sunoem)
3.24 IEKANALYZER (ipmiutil ekanalyzer, deprecated)
3.25 ITSOL (ipmiutil tsol)
3.26 IDELLOEM (ipmiutil delloem)
3.27 IDCMI (ipmiutil dcmi)
3.28 ISMCOEM (ipmiutil smcoem)
3.29 ISELTIME (iseltime)
3.30 IUSER (ipmiutil user)
4.0 Use Cases
4.1 Usage of IPMI utilities for sensor thresholds
4.2 Usage to configure a system for IPMI LAN
4.3 Usage of IPMI utilities for Automated IPMI LAN configuration
4.4 Usage of IPMI utilities to Set Watchdog timer
4.5 Usage of kernel panic handler code
4.6 Interpreting BMC LAN SNMP Traps from Platform Events
4.7 Interpreting newer PECI sensors for CPU Thermal Margin
4.8 How to configure a system for IPMI Serial-Over-LAN Console
4.9 Using ipmiutil Library APIs for custom programs
4.10 How to configure a system for SNMP Traps via IPMI PEF rules
5.0 IPMI Utilities on Windows
5.1 Windows Install Instructions
5.2 Windows Build Instructions
5.3 Windows Command Usage
6.0 Sample output
7.0 Problems
7.1 Error Return Codes
7.2 IPMI Completion Codes
8.0 Building IPMI Utilities
8.1 Building ipmiutil on Linux
8.2 Building ipmiutil on Windows
8.3 Building ipmiutil on Solaris
8.4 Building ipmiutil on FreeBSD
8.5 Building ipmiutil on ARM (Android)
9.0 IPMIUtil Library APIs
10.0 Related Information
9.1 History
9.2 Links
------------------------
1.0 OVERVIEW
------------------------
The IPMI Specification provides a standard way to do both simple and complex
server management functions. Everything from remote reset/power-off to sending
an SNMP alert from a sensor event even if the OS is down. Being able to
perform these tasks in Baseboard Management Controller (BMC) firmware allows
OS-independent management. What many integrators need, however, is a set of
utilities and/or sample code to perform these functions within their
enterprise management subsystem without a learning curve.
The IPMI Management Utilities project provides a series of utilities that
perform common IPMI server management functions, such as viewing the firmware
log, or configuring the BMC LAN & PEF features.
The utilities are designed for end-users, so that they should not require
intimate knowledge of how to build IPMI commands. Each of the utilities detects or reasonably assigns default values so that a working configuration can be
easily obtained. More detailed options allow changes to these default values.
These utilities can be used separately, or merged with a larger server
management subsystem. The source license is BSD and ipmiutil compiles under
Linux (Makefile) and Windows (buildwin.cmd). There are also corresponding
SA Forum HPI standard utilities that run with two different HPI
implementations, including OpenHPI. These were the basis of the current
openhpi/clients.
This project includes both IPMI utilities and a kernel patch for
panic handler enhancements. See the project web site for binaries
and documentation at http://ipmiutil.sourceforge.net.
The ipmiutil IPMI utilities below allow the user to access the firmware
System Event Log and configure the Platform Event Filter table for the new
'OS Critical Stop' records, as well as other common IPMI system management
functions.
ipmiutil - a meta-command to invoke all of the below as sub-commands
ievents - a standalone utility to interpret IPMI and PET event data
isel - show/set the firmware System Event Log records
isensor - show Sensor Data Records, sensor readings, and thresholds
ireset - cause the BMC to hard reset or power down the system
ilan - show and configure the BMC LAN port and Platform Event Filter
table to allow BMC LAN alerts from firmware events and
OS Critical Stop messages,
iserial - show and configure the BMC Serial port for various modes,
such as Terminal Mode.
ifru - show the FRU chassis, board, and product inventory data,
and optionally write a FRU asset tag.
ialarms - show and set front panel alarms (LEDs and relays)
iwdt - show and set watchdog timer parameters
igetevent - receive any IPMI events and display them
ihealth - check and report the basic health of the IPMI BMC
iconfig - list/save/restore the BMC configuration parameters
icmd - send specific IPMI commands to the BMC,
mainly for testing and debug purposes.
idiscover - discover the available IPMI LAN nodes on a subnet
isol - start/stop an IPMI Serial-Over-LAN Console session
ipicmg - show/set the IPMI PICMG parameters
ifirewall - show/set the IPMI firmware firewall configuration
iekanalyzer - run FRU-EKeying analyzer on FRU files
ifwum - OEM firmware update manager extensions
ihpm - HPM firmware update manager extensions
isunoem - Sun OEM functions
idelloem - Dell OEM functions
itsol - Tyan SOL console start/stop session
idcmi - get/set DCMI parameters, if supporting the DCMI spec
Other supporting files:
checksel = cron script using ipmiutil sel to check the SEL, write new
events to the OS system log, and clear the SEL if nearly full.
ipmi_port = daemon to bind the RMCP port and sleep to prevent
Linux portmap from stealing the RMCP port
ipmi_port.sh = init script to reserve the RMCP port from portmap,
this also restores saved sensor thresholds, if any.
ipmiutil_wdt = init script to restart watchdog timer every 60 sec via cron
ipmiutil_asy = init script runs 'ipmiutil getevt -a' for remote shutdown
ipmiutil_evt = init script runs 'ipmiutil getevt -s' for monitoring events
evt.sh = sample script which can be invoked by ipmiutil_evt
ipmi_if.sh = script using dmidecode to determine the IPMI Interface Type
bmclanpet.mib = SNMP MIB for BMC LAN Platform Event Traps
test/* = scripts and utilities used in testing ipmiutil/panicsel
kern/* = kernel patches for panic handling
The kernel panic handler patch (kern/bmcpanic.patch) adds additional
features to the Linux Panic Handler so that more information can be
saved and passed along if a Linux panic condition occurs.
bmc_panic features:
1. Write an OS Critical Stop event to firmware System Event Log (SEL)
This is in bmcpanic.patch, in OpenIPMI and in Intel IMB.
2. Send SNMP trap via BMC LAN Alerting mechanism
Accomplished by configuring the BMC with 'ipmiutil lan'.
3. Turn on the Critical Alarm LED on the Telco Alarms Panel
This is in bmcpanic.patch, but not in OpenIPMI due to
platform-specific issues with the alarms panel.
The kernel portion of this, except item 3, is now included in the OpenIPMI
project with the CONFIG_IPMI_PANIC_EVENT option, and the OpenIPMI
driver has merged into Linux kernel 2.4.21 and beyond.
The latest version of the OpenIPMI driver can be obtained from
http://openipmi.sourceforge.net.
This patch is also included in the Intel IMB IPMI driver v28 and greater,
for any Linux kernel. This Intel IMB IPMI driver can be obtained from
http://downloadcenter.intel.com/Product_Search.aspx?Prod_nm=imbsrc or
a copy is cached on http://ipmiutil.sf.net also.
------------------------
1.1 FEATURES
------------------------
These are the key strengths, user features and functions that are
supported by ipmiutil.
Key Strengths = supports any IPMI server platforms,
top-down user-friendly IPMI functions,
only IPMI project to support Windows natively,
detection, portability,
incorporates fixes and new features quickly
Target Market = Administrators, Developers, and OEMs
License = BSD (supports open or proprietary use)
OS Support = Linux, Windows, Solaris, FreeBSD, and MacOSX
(supports Windows natively for local or remote interface)
Drivers = For Linux: openipmi, imb, valinux ipmikcs, lan, lanplus,
landesk, and driverless direct KCS or SSIF
For Windows: Intel IMB and Microsoft IPMI drivers
For Solaris: bmc
For FreeBSD: openipmi, driverless KCS or SSIF
For MacOSX: remote only
Discrete sensors = Show interpreted meaning or raw value instead of 'na'
LEDs = Show/set ATCA LEDs, set identify LED, Intel Telco Alarm LEDs
health = show overall health and product information
discovery = find all IPMI LAN servers on a given subnet
fru = Display all FRU and SPD inventory data, also
Set some FRU product fields (asset tag, serial number)
sensor = Show SDRs and sensor readings, also set sensor thresholds
getevent = Receive any IPMI events and decode them,
The IPMI event monitoring service is automated in Linux via
the ipmiutil_evt init script.
reset = IPMI local and remote reset/power-control,
IPMI boot device selection.
remote soft-boot = Perform a remote OS shutdown/restart request, soft-shutdown
using ipmiutil getevt -a and invoking ipmiutil reset -o.
This async bridge service is automated in Linux via the
ipmiutil_asy init script, without requiring acpid.
cmd = Execute raw IPMI commands locally or remotely
lan = Show/set IPMI LAN and PEF configuration parameters,
adds more PEF rules, or can add a custom PEF rule
serial = Show/set IPMI serial configuration parameters
sel = Show decoded System Event Log records, clear SEL,
see the checksel cron script to automate SEL management.
sol console = Start/stop an SOL console session
watchdog = Show, set, and reset the IPMI watchdog timer and its actions,
The watchdog timer service can be automated in Linux via the
ipmiutil_wdt init script.
save/restore = save and restore all BMC configuration parameters
ievents = Standalone app to decode IPMI or PET event data,
especially useful at the management station for interpreting
IPMI PET SNMP traps. See also SNMP PET MIB (bmclanpet.mib).
picmg = Support IPMI PICMG functions
firewall = Support IPMI firmware firewall functions
Through various services, ipmiutil allows automatic management of common
IPMI tasks:
ipmi_port = Automatically prevent Linux port mapper from stealing
the RMCP port 623 used by IPMI LAN firmware.
checksel = a cron script to daily write new SEL records to syslog, and
clear the SEL if nearly full.
ipmiutil_asy = A Linux init script using the ipmiutil getevt -a service to
enable receiving soft-shutdown requests from ipmiutil reset -o
ipmiutil_wdt = A Linux init script to reset the watchdog timer every 60 sec.
ipmiutil_evt = A Linux init script using the ipmiutil getevt -s service to
monitor IPMI events, log them, and optionally run a script.
------------------------
2.0 DEPENDENCIES
------------------------
The IPMI Utilities will run on Linux, Windows Solaris, or FreeBSD, and should
be portable to other OSs, if an IPMI driver for that OS can be obtained.
The IPMI Utilities and Panic Handler Enhancements currently work with
platforms that support the IPMI standard. If the platform does not
support IPMI, these changes are inert. The Service Availability Forum
has developed a Hardware Platform Interface (HPI) specification that
can be used to group IPMI and other system management interfaces
together. A set of comparable HPI utilities is included in the
ipmiutil project source as hpiutil/*.
The Panic Handler kernel enhancements (via kern/bmcpanic.patch) are now
included in the Intel IMB driver v28 and later, and in the OpenIPMI driver
via the CONFIG_IPMI_PANIC_EVENT and CONFIG_IPMI_PANIC_STRING parameters in
the kernel config file (/usr/src/linux/.config) with kernels 2.4.21 or greater.
If run locally, the ipmiutil utilities must be run as
superuser/Administrator and an IPMI driver must be used.
For Linux, these IPMI drivers are supported:
. the MontaVista OpenIPMI driver (/dev/ipmi0),
. the Intel IMB IPMI driver (/dev/imb, via 'ipmidrvr' or 'ipmi_imb'),
. the valinux IPMI Driver (/dev/ipmikcs),
. the LANDesk ldipmi daemon,
. or direct user-space I/Os to the IPMI KCS or SSIF/SMBus interfaces,
if no other driver is detected.
For Windows, these drivers are supported:
. the Intel IMB IPMI driver (imbdrv.sys) for any Windows Server OS,
. the Microsoft IPMI driver (ipmidrv.sys) for Win2003R2 or Win2008.
For Solaris, these drivers are supported:
. the Sun bmc driver (/dev/bmc) for Solaris 10 and greater
For FreeBSD, these drivers are supported:
. the FreeBSD 7.x OpenIPMI driver port (kldload ipmi, /dev/ipmi0)
. direct user-space I/Os to the IPMI KCS or SSIF/SMBus interfaces
Each of the IPMI management utilities will detect which IPMI driver
is present, and in Linux, if none are found, it will attempt to use direct
KCS or SSIF I/Os to communicate with the IPMI BMC.
If using the IPMI LAN interface, neither the local or remote system requires
any IPMI driver, but the remote target system must have had IPMI LAN enabled,
(e.g. via ipmiutil lan) which is done locally on the target system.
Note that the IPMI LAN session password is sent with either MD5 or MD2
encryption by default.
See http://openipmi.sourceforge.net for the OpenIPMI driver.
See http://downloadcenter.intel.com/Product_Search.aspx?Prod_nm=imbsrc for Intel IMB driver
See http://cvs.sf.net/cgi-bin/viewcvs.cgi/ipmitools/ipmitools/kernel/kcs/patches/2.4.x/ for the valinux driver.
See http://www.landesk.com/ or the CD supplied with your server for LANDesk.
List of companies that have adopted IPMI (over 198):
http://www.intel.com/design/servers/ipmi/adopterlist.htm
Example IPMI Server Platforms tested with ipmiutil, by BMC manufacturer:
Intel RackMount Servers (various, both 32-bit and 64-bit)
Intel ATCA (MPCMM0001 and MPBL00xx)
Kontron CRMS servers and KTC5520
Dell PowerEdge 18xx, 19xx, 2800
SuperMicro with AOC-IPMI20 (by LMC)
SuperMicro with AOC-SIMSO (by Peppercon)
Sun (product id 0x4701)
Tyan (product id 0x14e9)
NSC (product id 0x4311, National SemiConductor)
NEC (product id 0x024b)
Tatung TS-2552 (product id 0x09f8)
AMI IPMI MegaRAC
------------------------
2.1 CONFIGURATION
------------------------
To find the base address of the IPMI KCS interface, or to find the IPMI
SSIF/SMBus slave address, you can use the 'dmidecode' utility provided
with most Linux distributions. See also http://www.nongnu.org/dmidecode.
The ipmi_if.sh script can determine the IPMI Interface Type, and the
resulting /usr/share/ipmiutil/ipmi_if.txt file can be edited if needed.
The ipmiutil binary uses the same mechanism to detect the IPMI KCS or
SSIF interface parameters by default if no driver is loaded.
For some IPMI systems, a minimum firmware version may be needed to
support the BMC LAN/PEF feature. On an Intel TSRLT2 system, for instance,
these are the minimum levels:
BMC Firmware ver 54 or greater
Systems with IPMI versions prior to 1.5 do not support BMC LAN or PEF features
By default, the ipmiutil IPMI utilities rpm does not set the panic timeout.
If a different kernel panic timeout is desired, add the kernel parameter
"panic=10" in grub.conf/lilo.conf, or do "echo 10 >/proc/sys/kernel/panic"
in one of the /etc/init.d scripts to set it to 10 seconds, for instance.
The ipmiutil lan (ilan) utility can be used to configure the BMC LAN
Alerting while the OS is running. It has additional PEF rules and LAN
parameter detection logic beyond what most other utilities provide.
The ipmiutil serial (iserial) utility is intended to configure the EMP
serial port on the server for shared access between BMC/IPMI functions
and BIOS Console Redirection. Some older platforms only support only Basic
Mode for BMC/IPMI functions. Basic Mode requires a remote client application
to utilize it (Windows ISC Console/DPC applet, or a special modified Linux
telnet). There are many platforms which implement Terminal Mode via IPMI v1.5
Appendix E to make remote management with character commands available
on the serial port without a special remote client application.
Notes about BMC Users:
Most IPMI 1.5 systems support at least 3 users, numbered 1,2,3, where
user 1 is the default and has a null username. Users 2 and 3 are
alternate users whose usernames can be set. For ipmiutil, these are
currently implemented by default as follows:
user 1: used by default for BMC LAN and Serial (ilan & iserial)
user 2: set for BMC LAN if ipmiutil lan -u is specified
user 3: set for BMC Serial/EMP if ipmiutil serial -u is specified
Also note that the -q option can be used to set different users by number.
Note that the checksel script will be copied to /etc/cron.daily when
the Linux ipmiutil rpm is installed, so that ipmiutil sel will automatically
save SEL records to syslog and clear the SEL if it gets nearly full.
If you do not want this to happen automatically, remove the checksel
script from the /etc/cron.daily directory.
In order for the ipmiutil sel -w function to work cleanly on a Windows system,
the showselmsg.dll should be copied to %SystemRoot%\system32, and the
showsel.reg should be run to set up the corresponding EventLog service
registry values. See install.cmd to perform these functions.
The BSD License in the COPYING file applies to all source files
herein, except for
* util/md5.c (Aladdin unrestricted license, compatible with BSD)
* util/md2.h (GPL)
* util/ipmi_ioctls.h (GPL)
While the BSD License allows code reuse in both open and non-open
applications, the md2.h and ipmi_ioctls.h files would have to be removed
if used in a non-open application. The default ipmiutil build omits GPL code.
There is a ALLOW_GPL compile flag for this that is disabled by default, but
can be enabled for open-source by running "./configure --enable-gpl".
See the INSTALL file for build instructions for various configurations.
------------------------
2.2 REFERENCES
------------------------
The IPMI 1.5 spec, Table 36-3 defines the sensor types for SEL records,
as used by ipmiutil sel.
The IPMI 1.5 spec, Table 15-2 defines the Platform Event Filter table
entries, as used by ipmiutil lan.
The IPMI 1.5 spec, Table 19-4 defines the LAN Configuration Parameters,
as used by ipmiutil lan.
The IPMI 2.0 spec, Section 15 defines the Serial-Over-LAN functionality.
The enterprises.3183 SNMP traps come from the BMC firmware, and are defined in
bmclan*.mib files in the ipmiutil project. Details about the format of these
Platform Event Traps are available in section 12.2 through 12.5 of the ISM
(Intel Server Management) 5.x Technical Product Specification at
http://www.intel.com/support/motherboards/server/isc/sb/cs-008024.htm
The enterprises.343 SNMP traps come from ISM or SNMPSA and are defined in
basebrd*.mib or mapbase*.mib files on the platform CD.
The enterprises.412 SNMP traps come from ISM/DMTF, defined in dmtf*.mib files
on the platform CD.
------------------------
3.0 UTILITY MAN PAGES
------------------------
--------------------------------------
3.1 IPMIUTIL (ipmiutil)
IPMIUTIL(8) IPMIUTIL(8)
NAME
ipmiutil - a meta-command to invoke various IPMI functions.
SYNOPSIS
ipmiutil <command> [-x -NUPREFJTVY] [other command options]
DESCRIPTION
This utility performs various IPMI functions. Each of the individual
commands in the ipmiutil project can be invoked via this meta-command.
The <command> is one of the following:
alarms show/set the front panel alarm LEDs and relays
leds show/set the front panel alarm LEDs and relays
cmd send a specified raw IPMI command to the BMC
config list/save/restore BMC configuration parameters
dcmi get/set DCMI parameters
discover discover all IPMI servers on this LAN
ekanalyzer run FRU-EKeying analyzer on FRU files (deprecated, see fru)
events decode IPMI events and display them
firewall show/set firmware firewall functions
fru show decoded FRU inventory data, write asset tag
fwum OEM firmware update manager extensions
getevt get IPMI events and display them, event daemon
getevent get IPMI events and display them, event daemon
health check and show the basic health of the IPMI BMC
hpm HPM firmware update manager extensions
lan show/set IPMI LAN parameters and PEF table
picmg show/set picmg extended functions
reset cause the BMC to reset or power down the system
sel show/clear firmware System Event Log records
sensor show Sensor Data Records, readings, thresholds
serial show/set IPMI Serial & Terminal Mode parameters
sol start/stop an SOL console session
smcoem SuperMicro OEM functions
sunoem Sun OEM functions
delloem Dell OEM functions
tsol Tyan SOL console start/stop session
wdt show/set/reset the watchdog timer
For help on each command (e.g. ’sel’), enter:
ipmiutil sel -?
For man pages on each command, its man page is named "i<command>", or
refer to SEE ALSO below.
This utility can use either the /dev/ipmi0 driver from OpenIPMI, the
/dev/imb driver from Intel, the /dev/ipmikcs driver from valinux,
direct user-space IOs, or the IPMI LAN interface if -N is used.
OPTIONS
Command options are described in the man page for each command. Below
are a few of the common options.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
EXAMPLES
ipmiutil sel
Shows the IPMI System Event Log entries.
ipmiutil wdt
Shows the watchdog timer values.
SEE ALSO
ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8) ifirewall(8)
ifru(8) ifruset(8) ifwum(8) igetevent(8) ihealth(8) ihpm(8) ilan(8)
ipicmg(8) ireset(8) isel(8) isensor(8) iserial(8) isol(8) isunoem(8)
iwdt(8) ipmiutil(8) ipmi_port(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.2 IALARMS (ipmiutil alarms)
IALARMS(8) IALARMS(8)
NAME
ipmiutil_alarms - display and set alarm indicators
SYNOPSIS
ipmiutil alarms [-abcdimnoprx -N node -U user -P/-R pswd -EFJTVY]
DESCRIPTION
ipmiutil alarms is a program that uses IPMI commands to display and set
alarm indicators, which are usually LEDs on the system chassis front
panel. This utility can use either the /dev/ipmi0 driver from
OpenIPMI, the /dev/imb driver from Intel, the /dev/ipmikcs driver from
valinux, direct user-space IOs, or the IPMI LAN interface if -N. Note
that a LAN user must have Administrative privileges to read or write
the alarm LEDs.
Note that this utility may not be the only logic setting alarm states.
The BMC firmware, system management software, or cluster fault manager
may also want to set alarm states. Intel provides a Telco Alarms Man-
ager API which presents a consolidated interface for all alarm manage-
ment applications.
OPTIONS
Command line options are described below.
-r Read-only. Show the alarms status, but do not set any states.
This is also the default mode if no parameters are specified.
-iN Sets the Chassis Identify feature, which can be an LED or some
other alarm. If N=0, turn off the Chassis ID, otherwise turn
the ID on for N seconds. N=255 will turn on the ID indefi-
nitely, if it is IPMI 2.0.
-aN Sets Disk A Fault LED. If N=0, turn it off. If N=1, turn it
on. Used only for TIGPT1U platform.
-bN Sets Disk B Fault LED. If N=0, turn it off. If N=1, turn it
on. Used only for TIGPT1U platform.
-dXN Sets Disk X Fault LED, where X=0-6. If N=0, turn it off. If
N=1, turn it on. Used only for NSC2U platform.
-cN Sets the Critical Alarm. If N=0, turn it off. If N=1, turn it
on.
-mN Sets the Major Alarm. If N=0, turn it off. If N=1, turn it on.
-nN Sets the Minor Alarm. If N=0, turn it off. If N=1, turn it on.
-pN Sets the Power Alarm. If N=0, turn it off. If N=1, turn it on.
Note that the Power LED is also wired to the System Fault LED in
the back of the system, so this state may be off for Power, but
the LED could be lit for a System Fault reason instead. Refer
to the system Technical Product Specification for System Faults.
-o Sets all alarms off, including the Chassis ID.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use this IPMI LAN Authentication Type: 0=None, 1=MD2, 2=MD5,
4=Straight Password, 5=OEM.
-V Use this IPMI LAN privilege level. 1=Callback level, 2=User
level, 3=Operator level, 4=Administrator level (default), 5=OEM
level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
SEE ALSO
ipmiutil(8) iconfig(8) icmd(8) idiscover(8) ievents(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.3 ICMD (ipmiutil cmd)
ICMD(8) ICMD(8)
NAME
ipmiutil_cmd - a tool to send specific IPMI commands via the command
line.
SYNOPSIS
ipmiutil cmd [-qsx -NUPREFJTVY] bus rsSa netFn/lun cmd [data bytes]
DESCRIPTION
This ipmiutil cmd tool sends specific IPMI commands to the firmware.
The commands are composed as hex values on the command line. This tool
was written to allow in-band use to match the DOS CMDTOOL.EXE or IPMI-
TOOL.EXE program which is distributed with many Intel servers. Certain
scripts or pre-written commands may have been supplied for the DOS tool
that can now be used while the system is running Linux or Windows.
This utility can use either the /dev/ipmi0 driver from OpenIPMI, the
/dev/imb driver from Intel, the /dev/ipmikcs driver from valinux,
direct user-space IOs, or the IPMI LAN interface if -N.
This tool should only be used if you are familiar with the IPMI 1.5
specification, or you have specific pre-written commands to send.
OPTIONS
Command line options are described below.
-q Quiet mode. Show only minimal header information.
-s Skips the GetDeviceID command
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
PARAMETERS
The following parameters are used by icmd. Each is represented as a
two-digit hex byte. The parameters have no default values.
bus This byte contains the bus number for this command, usually 00.
rsSa This is the resource slave address, usually 0x20 for the BMC.
netFn/lun
This byte combines the net Function and Lun. The 2 low-order
bits are the Lun and the 6 high-order bits are the net Function.
This representation is consistent with the DOS CMDTOOL/IPMITOOL.
cmd This byte contains the IPMI command.
[data bytes]
This is a sequence of zero to 16 bytes that represent data bytes
specific to this command.
EXAMPLES
icmd 00 20 18 01
Sends the GetDevice ID command to the BMC.
icmd 00 20 28 43 00 00 ff ff 00 ff
Sends a Get SEL entry command for the last entry in the firmware log.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) idiscover(8) ievents(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.4 ICONFIG (ipmiutil config)
ICONFIG(8) ICONFIG(8)
NAME
ipmiutil_config - list, save, and restore BMC configuration parameters
SYNOPSIS
ipmiutil config [-lpxLNUPREFJTVY] [-r file] [-s file]
DESCRIPTION
ipmiutil config is a program that uses an IPMI driver to send IPMI com-
mands which list, save and restore BMC configuration parameters for
LAN, Serial, PEF, SOL, User, Channel. This combines the functionality
of ipmiutil lan (ilan) and ipmiutil serial (iserial). Note that some
of the LAN parameters cannot be restored remotely over the IPMI LAN,
changing the configuration that is in use. This utility can use either
the /dev/ipmi0 driver from OpenIPMI, the /dev/imb driver from Intel,
the /dev/ipmikcs driver from valinux, direct user-space IOs, or the
IPMI LAN interface if -N.
OPTIONS
Command line options are described below.
-l Lists BMC configuration parameters with a keyword, index, and
its hex values. This is the default behavior if no options are
specified.
-r config_file
Restores BMC configuration from config_file, which was produced
with -s below.
-s config_file
Saves BMC configuration to config_file. This file could be
edited, in certain cases, such as to vary the BMC IP address
(LanParam 3), or to use the UserPassword records. Note that
lines beginning with ’#’ are comments and are ignored. For
editing UserPassword records, convert your text value to hex
format; for example "echo ’mypassword’ |od -t x1", and leave off
the trailing 0a.
-x Causes extra debug messages to be displayed.
-p password_to_set
This specifies the firmware password to set for BMC LAN access
for all users during the restore. If not specified, the pass-
word configuration will not be changed, unless a valid UserPass-
word record is present in the file to be restored. Note that
user passwords are write-only via standard IPMI commands.
-L lan_ch_num
This specifies the IPMI LAN channel number used for BMC LAN.
This varies by platform, and can be found in the platform tech-
nical specifications. By default, bmcconfig scans all IPMI
channels to find a LAN channel for BMC LAN.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
SEE ALSO
ipmiutil(8) ialarms(8) icmd(8) idiscover(8) ievents(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.5 IDISCOVER (ipmiutil discover)
IDISCOVER(8) IDISCOVER(8)
NAME
ipmiutil_discover - discover IPMI LAN-enabled nodes
SYNOPSIS
idiscover [-abegisx]
DESCRIPTION
idiscover is a program that uses IPMI LAN commands to discover any
nodes on the LAN that are available, by probing the RMCP port (623.)
on those nodes. This utility uses IPMI LAN, so no IPMI drivers are
needed. There are three methods that can be used:
-a = broadcast RMCP ping method (default)
-g = GetChannelAuthCap command method
else = specific RMCP ping method
A beginning IP address can be specified with -b for broadcast and spe-
cific methods. An ending IP can be specified for non-broadcast methods.
OPTIONS
Command line options are described below.
-a All nodes, use the broadcast ping method. This is the default
if no options are specified. This will detect the first enabled
ethernet interface, and defaults to the broadcast address
x.x.x.255 (where x.x.x.x is IP address) unless -b is used to
specify otherwise.
-b <ip>
Beginning IP address, required, unless using broadcast with
defaults. This could be a specific IP address, or a broadcast
address, ending in 255, if the broadcast method (-a) is used.
-e <ip>
Endign IP address of the range. Not used for broadcast method.
If this is not specified, a range of one IP address matching the
beginning IP is assumed.
-g Use the GetChannelAuthenticationCapabilities command method over
IPMI LAN instead of the RMCP ping. Not compatible with broad-
cast. This may be useful if the vendor BMC does not support
RMCP ping for some reason.
-i eth0
The interface name to use when sending the probes. The default
is to detect the first enabled ethernet interface (e.g. eth0).
-m shows MAC address. Uses the broadcast ping method, but uses a
raw socket so that the MAC address can be displayed. This
detects the first enabled ethernet interface, and defaults to
the broadcast address 255.255.255.255 like -a. Using -m with
raw sockets requires root privilege.
-r N Repeat the ping N times to each node. Default is to send 1 ping
per node.
-x Causes extra debug messages to be displayed.
EXAMPLES
idiscover -a -b 192.168.1.255
Sends a broadcast RMCP ping to discover IPMI LAN nodes on the specified
subnet.
idiscover -b 192.168.1.100 -e 192.168.1.254
Sends RMCP pings to a range of IP addresses.
idiscover -g -b 192.168.1.100 -e 192.168.1.254
Sends GetChannelAuthCap commands to a range of IP addresses.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) ievents(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.6 IEVENTS (ipmiutil events)
IEVENTS(8) IEVENTS(8)
NAME
ievents - decode IPMI and PET event data
SYNOPSIS
ievents [-bfhnprsx] 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10
DESCRIPTION
ievents is a standalone utility delivered with ipmiutil, used to inter-
pret raw hex data from IPMI events or from IPMI PET SNMP trap varbind
data. This utility uses the same interpretation logic as is used by
"ipmiutil sel" (showsel) and "ipmiutil getevt" (getevents).
The data bytes in the input are always assumed to be in hex form.
This could be useful if a utility other than "ipmiutil sel" were used
to obtain IPMI SEL records or events and interpretation is needed.
This would also be needed at an enterprise management station to inter-
pret the PET SNMP trap hex data into human-readable form, see option
-p.
OPTIONS
-b bin_file
Interpret a file containing raw binary/hex SEL data dumped in
binary form, such as that produced by "ipmitool sel writeraw
bin_file". Each set of 16 bytes in the file will be interpreted
as an IPMI event. (same as -h)
-f sel_file
Interpret a file containing raw ascii text SEL data captured
with ipmiutil sel -r, or some other similar utility. Each line
in the file should be in this form, with no leading spaces:
04 00 02 76 a9 4a 47 20 00 04 10 09 6f 42 0f ff
If this option is not specified, the default is to use the 16
bytes taken from the command-line arguments. (same as -r)
-h bin_file
Interpret a file containing raw binary/hex SEL data dumped in
binary form, such as that produced by "ipmitool sel writeraw
bin_file". Each set of 16 bytes in the file will be interpreted
as an IPMI event. (same as -b)
-n This option generates a New IPMI platform event, using 9 bytes
of input. The input bytes are the same as the last 9 bytes of
an IPMI event.
-p Decode as PET event bytes, where the input is 34 PET hex data
bytes, skipping the first 8 of the 47-byte PET data. The
default without -p assumes that the input is a 16-byte IPMI
event.
-r sel_file
Interpret a file containing raw ascii text SEL data captured
with ipmiutil sel -r, or some other similar utility. (same as
-f)
-s sensor_file
Sensor file with the output of "ipmiutil sensor", used to get
the PET sensor_type from the sensor_num. The default is
/usr/share/ipmiutil/sensor_out.txt as generated during the
ipmiutil package installation. This is only needed with PET
interpretation (-p).
-x show eXtra debug messages
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.7 IFRU (ipmiutil fru)
IFRU(8) IFRU(8)
NAME
ipmiutil_fru - show Field Replacable Unit configuration data
SYNOPSIS
ipmiutil fru [-abcdeikmsvx -N node -U user -P/-R pswd -EFJTVY]
DESCRIPTION
ipmiutil fru is a program that uses IPMI commands to show FRU configu-
ration data and optionally write an asset tag string into the FRU data.
Setting the asset tag is a function that can be used to uniquely iden-
tify the unit, even if the storage devices are removed or changed.
This utility can use either the /dev/ipmi0 driver from OpenIPMI, the
/dev/imb driver from Intel, the /dev/ipmikcs driver from valinux,
direct user-space IOs, or the IPMI LAN interface if -N.
OPTIONS
Command line options are described below.
-a asset_string
This option specifies an asset tag string to be written to the
baseboard FRU Product area. The asset tag length is limited by
the existing FRU Product data, but is usually allowed up to 16
characters. The default is to not modify this FRU field.
-b Only show the Baseboard FRU data. The default behavior is to
also scan for any SDR FRU data or DIMM SPD data referenced by
the SDRs.
-c Show FRU output in a canonical format, with a default delimiter
of '|'.
-d file
Dump binary FRU data to the specified file.
-e Show Every FRU output in a bladed chassis, including those under
child MCs. The default is to show FRUs referred to by just the
target MC.
-i 00 This option specifies a specific FRU ID to show. The input
value should be in hex (0b, 1a, etc.), as shown from the sensor
SDR output. By default, all FRU IDs that are specified in the
FRU locator SDRs are shown.
-k <setsn | setmfgdate | nextboot>
These Kontron OEM functions set FRU data based on existing data
stored elsewhere. The setsn option sets the FRU Board and Prod-
uct serial number, and the setmfgdate option sets the FRU Board
Mfg DateTime. The nextboot option specifies the boot device for
the next boot: BIOS, FDD, HDD, CDROM, or network. These options
are only supported on Kontron ATCA boards which have this func-
tionality.
-m 002000
Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). This
could be used for PICMG or ATCA blade systems. The trailing
character, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-s serial_num
This option specifies a serial number string to be written to
the baseboard FRU Product area. The serial number can be any
string up to 16 characters. The default is to not modify this
FRU field.
-v prod_ver
This option specifies a product version number string to be
written to the baseboard FRU Product area. The version number
can be any string up to 16 characters. The default is to not
modify this FRU field.
-x Causes eXtra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.8 IGETEVENT (ipmiutil getevt)
IGETEVENT(8) IGETEVENT(8)
NAME
ipmiutil_getevt - wait for IPMI events
SYNOPSIS
ipmiutil getevt [-abosx -t secs -N node -U user -P/-R pswd -EFJTVY]
DESCRIPTION
ipmiutil getevt is a program that uses IPMI commands to wait for IPMI
events sent from the BMC firmware. These events are also sent to the
IPMI System Event Log (SEL). This utility can use either the
/dev/ipmi0 driver from OpenIPMI, the /dev/imb driver from Intel, the
/dev/ipmikcs driver from valinux, direct user-space IOs, or the IPMI
LAN interface if -N.
Some server management functions want to trigger custom actions or
alerts when IPMI hardware-related events occur, but do not want to
track all events, just newly occurring events. This utility waits a
specified timeout period for any events, and returns interpreted output
for each event. It is designed as a scriptable command-line utility,
but if the timeout is infinite (-t 0), then this code could be used for
a sample service as well.
There are several methods to do this which are implemented here.
The SEL method:
This method polls the SEL once a second, keeps track of the last SEL
event read, and only new events are processed. This ensures that in a
series of rapid events, all events are received in order, however, some
transition-to-OK events may not be configured to write to the SEL on
certain platforms. This method is used if getevent -s is specified.
This is the only method supported over IPMI LAN, i.e. with -N.
The ReadEventMessageBuffer method:
This uses an IPMI Message Buffer in the BMC firmware to read each new
event. This receives any event, but if two events occur nearly simul-
taneously, only the most recent of the two will be returned with this
method. An example of simultaneous events might be, if a fan
stops/fails, both the non-critical and critical fan threshold events
would occur at that time. This is the default method for getevent.
The OpenIPMI custom method:
Different IPMI drivers may have varying behavior. For instance, the
OpenIPMI driver uses the IPMI GetMessage commands internally and does
not allow client programs to use those commands. It has its own custom
mechanism, see getevent_mv(). This method is used if the OpenIPMI
driver is detected, and no other method is specified.
The Async Event method:
This only gets certain Asynchronous requests from the BMC to an SMS OS
service, like a remote OS shutdown, and get_software_id. This method
is disabled by default and only turned on if the getevent -a option is
specified. This method is only supported via the Intel IMB and
OpenIPMI driver interfaces. There is an init script provided with
ipmiutil to automate the task of starting this async event daemon.
# chkconfig --add ipmiutil_asy (skip this if no chkconfig)
# /etc/init.d/ipmiutil_asy start
This listens for IPMI LAN requests for soft-shutdown, and logs the out-
put to /var/log/ipmiutil_asy.log
OPTIONS
Command line options are described below.
-a Use the Async request method, which receives SMS OS requests
from the BMC using the IMB or OpenIPMI driver interface. This
services remote SMS bridge agent requests, like remote OS shut-
down and get software_id.
-b Run in Background as a daemon. If this option is specified,
normal output will be redirected to /var/log/ipmiu-
til_getevt.log. The default is to run in foreground.
-c Show output in a canonical format, with a delimiter of '|'.
-e N Wait for a specific event sensor type N. The parameter can be
in hex (0x23) or decimal (35). The default is 0xFF which means
wait for any event.
-r F Run script file F when an event occurs. The filename can
include a full path. The script will be passed the event
description as a parameter. A sample evt.sh script is included
with the ipmiutil package.
-o Only run one pass to wait for the first event. Default is to
loop for multiple events for the timeout period.
-s Use the SEL method to get events. This polls the SEL once a
second for new events. The last SEL record read is saved in
/usr/share/ipmiutil/evt.idx. Otherwise, the default is to use
the ReadEventMessageBuffer method to get new events.
-t N Set the timeout period to N seconds. Default is 120 seconds. A
timeout of 0 means an infinite period.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.9 IHEALTH (ipmiutil health)
IHEALTH(8) IHEALTH(8)
NAME
ipmiutil_health- show IPMI health
SYNOPSIS
ipmiutil health [-ifhglmnopqsx -N node -U user -P/-R pswd -EFJTVY]
DESCRIPTION
ipmiutil health is a program that uses IPMI commands to show the health
of the BMC. This utility can use either the /dev/ipmi0 driver from
OpenIPMI, the /dev/imb driver from Intel, the /dev/ipmikcs driver from
valinux, direct user-space IOs, or the IPMI LAN interface if -N.
OPTIONS
Command line options are described below.
-c Show canonical, delimited output.
-f Show the FRUSDR version also.
-g Show the IPMI GUID of this system. The GUID is a read-only
unique identifier.
-h Check the health of the HotSwap Controller also.
-l Show the IPMI LAN channel statistics also.
-m 002000
Target a specific MC (e.g. bus 00, sa 20, lun 00). This could
be used for PICMG or ATCA blade systems. The trailing charac-
ter, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-n string
Set the System Name to this string in the IPMI System Informa-
tion.
-o string
Set the Primary Operating System to this string in the IPMI Sys-
tem Information.
-p 1 Set the chassis Power restore policy, governing the desired
behavior when power was lost and is restored. Values: 0 = stay
off, 1 = last state, 2 = always on.
-q string
Set the Secondary Operating System to this string in the IPMI
System Information.
-s Show the IPMI Session information also.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) igetevent(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.10 ILAN (ipmiutil lan)
ILAN(8) ILAN(8)
NAME
ipmiutil_lan - show and configure BMC LAN parameters and set up a PEF
entry to send BMC LAN Alerts for OS Critical Stop log events
SYNOPSIS
ipmiutil lan [-abcdefghijklmnopq#rstuvwxyzBDQK -i eth1 ]
[-I ipadr -M macadr -S subnet -B baud_sol ]
[-G gwyip -H gwymac -L lan_channel_num ]
[-A alertip -X alertmac -C community ]
[-u user_to_set -p password_to_set ]
[-N nodename -U username -Fimb ]
[-P/-R rmt_node_pswd -EFJTVY ]
DESCRIPTION
ipmiutil lan shows or sets all of the IPMI LAN Parameters to enable
remote LAN sessions or BMC LAN Alerts. The IP address and MAC address
of the local system, the default gateway, and the alert destination can
be defaulted to those specified in Linux, or can be overridden by user
parameters. It also creates a new Platform Event Filter table entry
for an OS Critical Stop (0x20) SEL firmware log event, so that it will
be enabled to send a BMC LAN Alert. This utility will skip the PEF
records if the system does not support IPMI 1.5 or greater. This util-
ity can use either the /dev/ipmi0 driver from OpenIPMI, the /dev/imb
driver from Intel, the /dev/ipmikcs driver from valinux, direct user-
space IOs, or the IPMI LAN interface if -N.
OPTIONS
Command line options are described below. Note that without options,
ipmiutil lan behaves as if option -r were used. To configure IPMI LAN
& PEF, use option -e.
-a alertnum
Specify which PEF alert number is to be used. Default is 1.
This would only be used if extra PEF alert destinations had been
set.
-b authmask
Specify a certain authtype mask in hex to use when configuring
this channel. The default mask is 0x16, so to include authtype
None (bit 0), it would require entering ’-b 17’.
-c Show Canonical output, which shows only interpreted text and
streamlines the parameters shown, using a common delimiter.
-d This option disables the IPMI LAN and PEF parameters, so as not
to allow BMC LAN connections or alerts. This option also sets
the IP address to zeros.
-e This option enables the BMC LAN configuration and PEF event
alerts. The utility will attempt to obtain the default BMC LAN
parameters from the OS automatically, or they can be specified
with command options below.
-f Set the ARP control parameter to 1 = gratuituous ARPs, 2 = ARP
responses, or 3 = both grat ARP and ARP responses. The default
is 1.
-g This specifies the secondary gateway IP address to use for the
BMC LAN. The default is to omit this parameter and only use the
default gateway. See also -G.
-h Set the IPMI VLAN ID to this value. Setting to a value >=4096
disables the VLAN ID. The default behavior is not to set this
parameter.
-i ethif
By default, the eth0 interface is used to find IP and MAC
addresses. Sometimes, however, the first ethernet port on the
baseboard may be represented by Linux as eth1 or eth2 instead.
If so, use this option to indicate the correct ethernet inter-
face to use. By default, ipmiutil lan will scan up to 32 eth
interfaces for the onboard one that BMC LAN uses.
-j This sets a custom PEF rule as the last PEF entry. The input is
a series of 10 hex bytes, forming the PEF entry. For example,
this sample PEF entry would perform a power down action if the
Baseboard Temp reached its threshold.
"ipmiutil lan -e -j020110ffff013001950a"
-k This causes ipmiutil lan to also insert two rules to send alerts
for transition-to-OK events, including Power Redundancy OK and
Temperature OK.
-l This option enables the BMC LAN configuration, but not PEF
events. The utility will attempt to obtain the default BMC LAN
parameters from the OS automatically, or they can be specified
with command options below.
-n num By default, the new PEF entry for OS Critical Stop is inserted
at offset 12 into the table. This can be changed to insert it
at an offset > 12 if another entry already exists at offset 12.
-o Disable Only SOL. This could be used after the IPMI LAN was
configured, to disable Serial-Over-LAN console access but still
allow other IPMI LAN access.
-p password_to_set
This specifies the firmware password to set for BMC LAN access.
If not specified, the user and password configuration will not
be changed.
-q Specify an alternate user number for the LAN username from the
-u option. This is normally user number 2, 3, or 4, where 2 is
the default. The maximum number of users is 15. Same as -#
below.
-# Specify an alternate user number for the LAN username from the
-u option. Same as -q above.
-r This option just reads the configuration without writing any BMC
LAN parameters or writing any new entries to the PEF table.
-s This option will also display some of the Serial parameters.
-t Test if the BMC LAN has already been configured. Returns 0 if
so.
-u username_to_set
This specifies the firmware username to set for BMC LAN access.
If a username is specified, user 3 will be set. If not speci-
fied, the default user 1 will be used.
-v priv
Set a specific access priVilege for this user, where priv can
be: 1=Callback, 2=User, 3=Operator, 4=Admin, 5=OEM, 15=NoAccess
The default if not specified or specified in error, is to use
4=Admin.
-w N Set the Gratuitous ARP Interval to N seconds. This has no
effect if the firmware does not support Grat-ARP, as shown in
Lan Param 10. If not set, the interval remains at the firmware
default.
-x Causes extra debug messages to be displayed.
-y N Set the OEM LAN Failover parameter to N. Values for N with
Intel Romley/S2600 baseboards: 1 = enable, 0 = disable. Val-
ues for N with SuperMicro baseboards: 2 = failover, 1 = lan1 , 0
= dedicated.
-z Also show the IPMI LAN Statistics
-A alert_ip_addr
This specifies the SNMP Alert Destination IP address to use for
the BMC LAN. By default, this utility will attempt to obtain
this from the /etc/snmp/snmpd.conf file, via the trapsink param-
eter. The alert destination will see the BMC LAN traps with the
enterprises.3183.1.1 OID. If no alert IP address is specified
in either snmpd.conf or this parameter, or if that IP address
does not respond, the other SNMP parameters for BMC LAN will be
skipped.
-B baud_sol
This specifies the Baud rate for SerialOverLan. The possible
values are: 9600, 19.2k, 38.4k, 57.6k, and 115.2k. The default
is 19.2k.
-C snmp_community
This specifies the SNMP Community name to use for BMC LAN
Alerts. The default community string is "public". This parame-
ter is ignored if there is no Alert IP address.
-D This causes the local IP address to be determined by DHCP
instead of a static IP address.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-G gwy_ip_addr
This specifies the default gateway IP address to use for the BMC
LAN. The default is to automatically obtain this from the Linux
route table.
-H gwy_mac_addr
This specifies the default gateway MAC address to use for the
BMC LAN. The format can be either 11:22:33:44:55:66 or
11-22-33-44-55-66. The default is to try to automatically
obtain this by sending an arp request from an OS LAN eth inter-
face: the default one, or as specified by -i.
-K hostname
This specifies the IPMI hostname to set, for Kontron servers
only. This enables the firmware to properly map the IP address
to a hostname, especially with the web interface. The default
is not to set this parameter, and use IP address only.
-I ip_addr
This specifies the local IP address to use for the BMC LAN on
eth0. The default is to automatically obtain this from the
Linux ifconfig.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-L lan_ch_num
This specifies the IPMI LAN channel number used for BMC LAN.
This varies by platform, and can be found in the platform tech-
nical specifications. For instance, Intel platforms usually use
channels 1 & 2 for onboard NICs, and channel 3 for optional RMM
NICs. By default, ipmiutil lan scans all IPMI channels to find
the first LAN channel for BMC LAN. To just list all IPMI chan-
nels to see what is available, use the string ’list’ instead of
a LAN channel number. This will list the channels and exit.
-M mac_addr
This specifies the local MAC address to use for the BMC LAN on
eth0. The format can be either 11:22:33:44:55:66 or
11-22-33-44-55-66. The default is to automatically obtain this
from the Linux ifconfig.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P rmt_pswd
Remote password for the nodename given. The default is a null
password. Same as -R below.
-Q Set the IPMI VLAN Priority. The default priority is 0.
-R rmt_pswd
Remote password for the nodename given. The default is a null
password. Same as -P above.
-S subnet
This specifies the local subnet mask to use for the BMC LAN on
eth0. The default is to automatically obtain this from the
Linux ifconfig.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-X alert_mac_addr
This specifies the SNMP Alert Destinations’s MAC address to use
for the BMC LAN. The format can be either 11:22:33:44:55:66 or
11-22-33-44-55-66. The default is to attempt to obtain this
from the Linux arp cache. This parameter is ignored if there is
no Alert IP address.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
EXAMPLES
To read existing settings:
ipmiutil lan -r
To enable IPMI LAN with default settings detected, assuming shared
MAC/IP:
ipmiutil lan -e
To set up IPMI LAN for a unique IP address and set PEF SNMP Alerts:
ipmiutil lan -e -I 192.168.1.1 -A 192.168.1.10
To set the IPMI LAN password for the default user:
ipmiutil lan -e -p mypassword
To disable access to the IPMI LAN channel:
ipmiutil lan -d
SAMPLE PEF TABLE
These 11 PEF table entries are configured from the factory for various
Intel Sahalee BMC systems, and will be applied as the defaults for a
system with an empty PEF table:
PEF(01): 01 Temperature Sensor event - enabled for alert
01 c0 01 01 00 ff ff 01 ff 01 95 0a 00 00 00 00 00 00 00 00 00
PEF(02): 02 Voltage Sensor event - enabled for alert
02 c0 01 01 00 ff ff 02 ff 01 95 0a 00 00 00 00 00 00 00 00 00
PEF(03): 04 Fan Failure event - enabled for alert
03 c0 01 01 00 ff ff 04 ff 01 95 0a 00 00 00 00 00 00 00 00 00
PEF(04): 05 Chassis Intrusion event - enabled for alert
04 c0 01 01 00 ff ff 05 05 6f 01 00 00 00 00 00 00 00 00 00 00
PEF(05): 08 Power Supply Fault event - enabled for alert
05 c0 01 01 00 ff ff 08 ff 6f 06 00 00 00 00 00 00 00 00 00 00
PEF(06): 0c Memory ECC Error event - enabled for alert
06 c0 01 01 00 ff ff 0c 08 6f 02 00 00 00 00 00 00 00 00 00 00
PEF(07): 0f FRB Failure event - enabled for alert
07 c0 01 01 00 ff ff 0f 06 6f 01 00 00 00 00 00 00 00 00 00 00
PEF(08): 07 BIOS POST Error event - enabled for alert
08 c0 01 01 00 ff ff 07 ff 6f 1c 00 00 00 00 00 00 00 00 00 00
PEF(09): 13 Fatal NMI event - enabled for alert
09 c0 01 01 00 ff ff 13 ff 6f 3e 03 00 00 00 00 00 00 00 00 00
PEF(10): 23 Watchdog Timer Reset event - enabled for alert
0a c0 01 01 00 ff ff 23 03 6f 0e 00 00 00 00 00 00 00 00 00 00
PEF(11): 12 System Restart event - enabled for alert
0b c0 01 01 00 ff ff 12 ff 6f 02 00 00 00 00 00 00 00 00 00 00
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) igetevent(8) ihealth(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.11 IRESET (ipmiutil reset)
IRESET(8) IRESET(8)
NAME
ipmiutil_reset - perform a hardware reset on the system
SYNOPSIS
ipmiutil reset [-bcdDefhijmnoprsuwxy -N node -U user -P/-R pswd
-EFJTVY]
DESCRIPTION
ipmiutil reset is a program that uses IPMI commands to perform a hard-
ware reset of the chassis, or boot to a specific device. This utility
can use either the /dev/ipmi0 driver from OpenIPMI, the /dev/imb driver
from Intel, the /dev/ipmikcs driver from valinux, direct user-space
IOs, or the IPMI LAN interface if -N.
OPTIONS
Command line options are described below.
-c Power Cycle the system chassis
-d Power Down the system chassis
-n Send NMI to the system
-u Power Up the system chassis
-r Hard Reset the system chassis
-D Do a soft shutdown of the OS, and then power down. Note that
remote soft shutdown (-D -N) for Intel S5000 baseboard requires
ipmiutil getevt -a running on the target server.
-o Do a soft shutdown of the OS, and then reset. Note that remote
soft shutdown (-o -N) for Intel S5000 baseboard requires ipmiu-
til getevt -a running on the target server.
-k Do a cold reset to restart the BMC firmware.
-m 002000s
Perform these function for a specific MC (e.g. bus 00, sa 20,
lun 00). The trailing character, if present, indicates SMI
addressing if ’s’, or IPMB addressing if ’i’ or not present.
-b Do a hard reset and reboot to the BIOS Setup menu, for this
reboot only.
-e Do a hard reset to EFI, if IPMI EFI boot is enabled, for this
reboot only.
-f Do a hard reset to Floppy/Removable, for this reboot only.
-h Do a hard reset to a Hard Disk, for this reboot only.
-i Set the boot Initiator mailbox string, usually for PXE use. The
string must be less than 78 characters.
-j Set the IANA number used for the boot Initiator mailbox string.
-p Do a hard reset and network boot to PXE server, for this reboot
only.
-s Do a hard reset and reboot to the Service/Diagnostic Partition,
for this reboot only. Reboots to the default if no service par-
tition is configured.
-v Do a hard reset to DVD/CDROM Media, for this reboot only.
-w Wait for BMC ready after a reset before exiting the utility.
-x Causes extra debug messages to be displayed.
-y Yes, try to persist any boot options used [-befhprsv]. This
requires the IPMI firmware to ask the BIOS to change boot order
settings, so it may not be supported by all BMC firmware ven-
dors.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) igetevent(8) ihealth(8) ilan(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.12 ISEL (ipmiutil sel)
ISEL(8) ISEL(8)
NAME
ipmiutil_sel - show firmware System Event Log records
SYNOPSIS
ipmiutil sel [-abcflswvx -N node -P/-R pswd -U user -EFJTVY]
DESCRIPTION
ipmiutil sel is a program that uses IPMI commands to to read and dis-
play the System Event Log (SEL) which is stored by the BMC firmware.
IPMI commands are issued to read each record, and, if specified, incre-
mentally write records that have not previously been read into the
Linux syslog (/var/log/messages). This utility can use either the
/dev/ipmi0 driver from OpenIPMI, the /dev/imb driver from Intel, the
/dev/ipmikcs driver from valinux, direct user-space IOs, or the IPMI
LAN interface if -N.
OPTIONS
Command line options are described below.
-a string
Add a SEL record with a string of up to 13 characters. Longer
strings will be truncated. Note that this should be used spar-
ingly, but would be useful for changes made to the hardware or
firmware environment, like "Fan replaced" or "flash FW2.1".
-b bin_file
Interpret a file containing raw binary/hex SEL data dumped in
binary form, such as that produced by "ipmitool sel writeraw
bin_file". Each set of 16 bytes in the file will be interpreted
as an IPMI event.
-c Show output in a canonical format, with a default delimiter of
'|'. (same as -n).
-d Deletes/Clears the SEL of all records. If the SEL becomes full
(free space = 0), it no longer accepts new records, so the SEL
should be cleared periodically (use checksel cron script).
-e Show Extended sensor descriptions for events if run locally.
This option will attempt to get the full sensor description from
/var/lib/ipmiutil/sensor_out.txt, and also use its SDR to decode
any raw threshold values in the event, if present.
-f sel_file
Interpret a file containing raw ascii text SEL data captured
with ipmiutil sel -r, or some other similar utility. Each line
in the file should be in this form, with no leading spaces:
04 00 02 76 a9 4a 47 20 00 04 10 09 6f 42 0f ff
Lines not in this format will be ignored.
-l N Show last N SEL records, in reverse order (newest first). For
some BMC implementations, this may not show all N records speci-
fied.
-n Show output in a nominal/canonical format, with a default delim-
iter of '|'. (same as -c).
-r Show the 16 raw hex bytes for each SEL entry. The default is to
display interpreted entries, and include relevant hex event
bytes.
-p By default, all SEL records are displayed. This option causes
only the Panic events with sensor_type = 0x20 (OS Critical Stop)
to be displayed.
-s N Show only SEL events with severity N or greater. Severity
0=INF, 1=MIN, 2=MAJ, 3=CRT. The default is to show all SEL
events.
-u Show the SEL time as UTC and also get the SEL Time UTC offset if
that command is supported. The default is to convert the SEL
Time to local time.
-v Only show the version information. This shows: the ipmiutil
sel utility version, the BMC version, the IPMI version, the SEL
version, and the amount of free space in the SEL.
-w This option writes SEL records to the Linux syslog
(/var/log/messages) or Windows Application Log. It only writes
SEL records that have timestamps newer than the last record
written to syslog. It saves the last timestamp in an index file
named /usr/share/ipmiutil/sel.idx (.\sel.idx in Windows).
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) igetevent(8) ihealth(8) ilan(8) ireset(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.13 ISENSOR (ipmiutil sensor)
ISENSOR(8) ISENSOR(8)
NAME
ipmiutil_sensor - show Sensor Data Records
SYNOPSIS
ipmiutil sensor [-abcdefgjkmpqrstuvwxL -i id -n snum -h tval -l tval
-NUPREFJTVY]
DESCRIPTION
ipmiutil sensor is a program that uses IPMI commands to show and decode
Sensor Data Records and current sensor readings for all sensors in the
system. This utility can use either the /dev/ipmi0 driver from
OpenIPMI, the /dev/imb driver from Intel, the /dev/ipmikcs driver from
valinux, direct user-space IOs, or the IPMI LAN interface if -N.
Note that this utility by default only displays Sensor Data Records
reported by from the Baseboard Management Controller. To show sensors
for other controllers, see options -b and -m below.
OPTIONS
Command line options are described below.
-a snum
ReArms the sensor number for events
-b Shows SDRs for Bladed (PICMG or ATCA) systems by traversing the
child MCs (same as -e).
-c Show sensor list in a simpler/Canonical format without uninter-
preted binary values. Only the user-friendly interpreted sensor
information is shown. (same as -s).
-d <file>
Dump the SDRs to a specified binary file. This file can be used
with -j to jumpstart getting the sensor readings.
-e Show Every SDR in a bladed system by traversing the child MCs
(same as -b).
-f <file>
Restore the SDRs from the specified binary File. This is nor-
mally only done with the initial factory provisioning.
-g sens_type
Shows only those SDRs matching the given sensor type group. The
sens_type string can be "fan", "temp", "voltage", or any string
or substring matching those in the IPMI 2.0 Table 42-3 for Sen-
sor Types. Multiple types can be listed, separated by a comma
(,) but no spaces.
-h tval
Highest threshold value to set for the specified sensor. This
tval can be in decimal, or of the form 0x1a, to match the raw
reading value shown by sensor following the " = ". The value
passed is set as the non-critical threshold value, with the more
critical ones set by the utility as incrementally lower. This
simplifies the interface and ensures that the threshold values
do not get out of order. This requires specifying the sensor
number via -n.
-i ID Show or set only the sensor Index corresponding to ID, where ID
is the hex ID of the SDR as shown in the sensor output under
"_ID_". The ID argument can be one hex number (e.g. 0x0e or
0e), or a range of hex numbers (e.g. 0e-1a or 1a,2a or
0x0e-0x2a). This is useful to repeatedly view just a few sensor
readings for changes, or to set just one sensor quickly without
reading all of the SDRs.
-j file
Jump-start by caching the SDRs from a file. This uses an SDR
binary file to read the SDRs, so that only the sensor readings
need to be read from the firmware. This avoids getting the SDR
reservation and reading each SDR, so it makes getting the sensor
readings more efficient. The SDR binary file can be created
using the -d option to dump the SDRs to a file, or -j will try
to create the file if not there.
-k K
When looping with -L, wait K seconds between loops. Default is
1 second.
-l tval
Lowest threshold value to set for the specified sensor. This
tval can be in decimal, or of the form 0x1a, to match the raw
reading value shown by sensor following the " = ". The value
passed is set as the non-critical threshold value, with the more
critical ones set by the utility as incrementally higher. This
simplifies the interface and ensures that the threshold values
do not get out of order. This requires specifying the sensor
number via -n.
-m 002000s
Show SDRs for a specific MC (e.g. bus 00, sa 20, lun 00). This
could be used for PICMG or ATCA blade systems. The trailing
character, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-n snum
Number of the sensor to set. This num can be in decimal, or of
the form 0x1a, to match the value shown by sensor following the
"snum" tag. This is required if setting hi/lo thresholds via
-h/-l.
-o Output the memory DIMM information from SMBIOS, including size.
Not available if using IPMI LAN via -N. Sample output:
Memory Device (0,0): DIMM_A1 : size=2048MB
Memory Device (0,1): DIMM_A2 : not present
-p Persist the threshold being set (as specified via -l or -h).
This writes a "sensor -i" script line to the file
/usr/share/ipmiutil/thresholds.sh, which can then be executed at
each reboot by starting the /etc/init.d/ipmi_port service for
the desired runlevels. For Windows, the filename is thresh-
olds.cmd.
-q Show threshold values in d:d:d format. Thresholds are shown for
each sensor in short format with ’:’ delimiters, which is useful
as an example for setting thresholds with ’-u’.
-r Show Raw SDR bytes also.
-s Show sensor list in a simpler/canonical format without uninter-
preted binary values. Only the user-friendly interpreted sensor
information is shown. (same as -c).
-t Show any Thresholds for each sensor also, in text format.
-u Set unique threshold values. The values are specified in a
string of threshold values. It can be in raw hex characters or
in float values. All 6 possible thresholds must be specified,
but only the ones that are valid for this sensor will be
applied. These values are validated for ordering. For example:
-u 6:5:4:60:65:69 (float) or
-u 0x0605043c4145 (raw hex)
would mean 0x06=noncrit_lo, 0x05=crit_lo, 0x04=nonrec_lo,
0x3c=noncrit_hi, 0x41=crit_hi, 0x45=nonrec_hi.
-v Show Verbose output, including volatile thresholds, SDR thresh-
olds, max/min, hysteresis, and BMC_TAM decoding.
-w Wrap the threshold data onto the same line as the sensor. This
may be convenient for scripting.
-x Causes eXtra debug messages to be displayed.
-L n Loop n times every K seconds. Default is one loop and K defaults
to 1 second. See option -k to change K seconds if desired.
This is useful along with -i or -g to read some sensors as they
change. Using -j with this option makes run it quicker.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
EXAMPLES
ipmiutil sensor sample output is below.
ipmiutil ver 2.21
sensor: version 2.21
-- BMC version 0.17, IPMI version 2.0
_ID_ SDR_Type_xx ET Own Typ S_Num Sens_Description Hex & Interp Read-
ing
000b SDR Full 01 01 20 a 01 snum 30 Baseboard Temp = 2e OK 46.00
degrees C
000e SDR Full 01 01 20 m 04 snum 50 Fan 1A = 6f OK 7659.00
RPM
0042 SDR Comp 02 6f 20 a 21 snum e0 DIMM 1A = 00 c0 04 00
Present
004e SDR FRU 11 1b dev: 20 03 80 00 0a 01 Pwr Supply 1 FRU
0050 SDR IPMB 12 1b dev: 20 00 bf 07 01 Basbrd Mgmt Ctlr
0051 SDR OEM c0 09 Intel: 02 02 00 01 70 71
0065 SDR OEM c0 11 Intel: SDR Package 17
[...]
Output Columns:
_ID_: This is an SDR ID or index number, in hex. This may vary from
chassis to chassis.
SDR_Type_xx: This shows the SDR Type and its hex representation. Some
SDR types have a custom display. The OEM SDRs only show the OEM vendor
by IANA number and then usually the data is listed in hex.
ET: For Full or Comp SDRs, this shows the Event Type. For other SDRs,
this shows the size of the SDR entry in hex (Sz).
Own: This is the hex slave address of the SDR Owner, usually 20 if BMC.
a/m: This indicates whether this sensor is either automatically or man-
ually rearmed, respectively.
Typ: This is the Sensor Type as defined in Table 42-3 of the IPMI 2.0
spec. (01 = Temperature, 02 = Voltage, 03 = Current, 04 = Fan, etc.)
S_Num: This is the sensor number in hex. This remains consistent
across baseboards of the same type. The output can be parsed with the
"snum" delimiter to extract this value.
Sens_Description: This is the text description of this SDR, which is
stored within the SDR on the BMC.
Hex & Interp Reading: This is the raw hex value returned by GetSensor-
Reading, and its interpreted meaning.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.14 ISERIAL (ipmiutil serial)
ISERIAL(8) ISERIAL(8)
NAME
ipmiutil_serial - configure a system for Serial/EMP management func-
tions, such as Terminal Mode, and optionally share the port with the
Serial Console.
SYNOPSIS
ipmiutil serial [-bcdeflq#rsvxB -m0 -m1 -n ser_chan -u user -p passwd
-NUPREFJTVY]
DESCRIPTION
ipmiutil serial is a program that uses an IPMI driver to send IPMI com-
mands which configure a system to enable EMP/serial Terminal Mode man-
agement functions within the firmware, so that an administrator can use
command-line character commands via the serial port to power cycle the
system and perform other functions, even if the system is not running
an OS. This level of access needs to be protected by a username/pass-
word login, which can be specified with this utility. This utility can
use either the /dev/ipmi0 driver from OpenIPMI, the /dev/imb driver
from Intel, the /dev/ipmikcs driver from valinux, direct user-space
IOs, or the IPMI LAN interface if -N.
OPTIONS
Command line options are described below.
-b Set up and enable the Serial Port EMP parameters for Basic Mode
management functions. This does not set a username or password.
-c Configure and enable the Serial Port EMP parameters for Terminal
Mode management functions, shared with BIOS Console Redirection.
Setting a new username and password for serial access via -u and
-p is recommended for security.
-d Disable the serial port access for IPMI commands. The serial
port is then only available for BIOS console and OS functions.
A side-effect of this option is that it sets the default user
(1) back to admin access.
-e Enable EMP Terminal Mode without shared BIOS console. The
serial port is then only available for EMP Terminal Mode func-
tions.
-f Specifies the Flow Control for the Serial EMP. 0 means no flow
control, and 1 means RTS/CTS flow control (default). This must
match the BIOS Serial Console setting.
-l Show LAN Parameters. This option reads and displays the LAN
Parameter configuration also.
-m0 Switch the Serial Port MUX to Baseboard/BIOS Console operation.
Set no other configuration parameters.
-m1 Switch the Serial Port MUX to Terminal Mode management. Set no
other configuration parameters.
-n ser_chan
Sets the IPMI channel number to use for the EMP serial channel
(often 4). Note that the IPMI channels for LAN, Serial, etc.
are numbered differently on each platform type. The default is
to detect the first available IPMI serial channel.
-# Same as -q below.
-q Specify an alternate user number for the EMP Username from the
-u option. This is normally user number 2, 3, or 4, where 3 is
the default. The maximum number of users is 15.
-r Read Only. This option just reads the Serial Parameter configu-
ration without writing any values.
-s Set up and enable the Serial Port EMP parameters for Shared
operation between Basic Mode management functions and Baseboard
(BIOS) Remote Console. This option switches the Serial Port MUX
to Baseboard Console operation.
-t Configure and enable the Serial Port EMP parameters for Terminal
Mode management functions, shared with BIOS Console Redirection.
Same as -c, but easier to remember.
-u username
This specifies a username for the EMP Terminal Mode login. It
can be any string, up to 15 characters. If -u is not used, the
default user 1 (null) will be assumed. The username, if speci-
fied, will be set for user 3, unless option -q is specified.
-p password
This specifies a password for the EMP Terminal Mode login. It
can be any string, up to 15 characters. A null password is used
if none is specified. This password applies to user 3 if -u is
used, to user 1 otherwise.
-v priv
Set a specific access priVilege for this user, where priv can
be: 1=Callback, 2=User, 3=Operator, 4=Admin, 5=OEM, 15=NoAccess
The default if not specified or specified in error, is to use
4=Admin.
-x Causes extra debug messages to be displayed.
-B Set the Baud rate of the serial port to one of the following:
9600, 19,2K, 38.4K, 57.6K, or 115.2K. The default is 19.2K bps.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
EXAMPLES
ipmiutil serial -t (or -c)
Enables Terminal Mode management functions, shared with BIOS
Serial Console redirection. The user can switch between serial
console operations and IPMI Terminal Mode commands by typing ESC
’)’ and ESC ’Q’.
ipmiutil serial -s
Enables Basic Mode management functions shared with BIOS Serial
Console redirection. The user can switch between serial console
operations and IPMI Basic Mode management programs on the same
serial port.
ipmiutil serial -d
Disables the serial port management functions. This would be
used if only the BIOS Serial Console were used and no BMC serial
management functions.
How to login to a Terminal Mode console:
ESC ( (switch to Terminal mode)
[SYS PWD -N ] (login for default user, null psw)
[SYS PWD -U ROOT -N PASSWORD] (syntax example for user 3)
[SYS 000157 ACTIVATE] (activate advanced commands)
[SYS HEALTH QUERY]
[SYS HELP]
[SYS PWD] (logoff)
ESC Q (switch to BIOS console)
See IPMI 1.5 Spec, Appendix E, and Intel TIGPR2U TPS for more informa-
tion.
DEPENDENCIES
The ipmiutil serial utility is intended to configure the EMP serial
port on the server for shared access between BMC/IPMI functions and
BIOS Console Redirection. Some platforms only support only Basic Mode
for BMC/IPMI functions. Basic Mode requires a remote client applica-
tion to utilize it (Windows ISC Console/DPC, or a special modified
Linux telnet). There are some platforms which implement Terminal Mode
via IPMI v1.5 Appendix E to make remote management with character com-
mands available on the serial port without a special remote client
application.
For example, Intel TSRLT2 systems would use "ipmiutil serial -s" for
Basic Mode shared functions, but Intel TIGPR2U systems could use
"ipmiutil serial -c" to configure Terminal Mode functions. On your
system, run "ipmiutil serial -r" to check whether Serial Param(29):
"Terminal Mode Config" is supported. If not, configure Basic Mode via
"ipmiutil serial -s".
PLATFORM SERIAL PORT CONFIGURATION EXAMPLES
First, enter BIOS Setup for Serial Console Redirection parameters:
(these vary by platform)
Console Redirection = Serial Port B
ACPI Redirection = Disabled
Baud Rate = 115.2K
Flow Control = CTS/RTS
Terminal Type = VT100
Legacy Redirection = Enabled
Note that the Baud Rate can vary, but it must match in all locations
where it is used (BIOS, IPMI, and Linux).
For some non-Intel platforms, the serial console would be COM1 instead
of COM2, but should be enabled in BIOS.
From Linux, run "ipmiutil serial -c" for Terminal Mode shared configu-
ration.
Or, on older Intel TSRLT2 platforms: From Linux, run "ipmiutil serial
-s" for Basic Mode Shared configuration.
LINUX CONFIGURATION FOR SERIAL CONSOLE
If using lilo, in /etc/lilo.conf, add
append="console=ttyS1,19200n8 console=tty0"
(and comment out the "message=" line because it includes graphics)
Note that the append line can be placed in the global section and
removed from each kernel section if there are no other differences.
Or, if using grub, edit /boot/grub/grub.conf as follows:
#Omit the splashimage or gfxmenu
# splashimage=(hd0,0)/grub/splash.xpm.gz
#The serial and terminal lines are not usually needed
# serial --unit=1 --speed=19200 --word=8 --parity=no --stop=1
# terminal --timeout=10 serial console
#Add the console=ttyS* parameter to the kernel line
kernel (hd0,0) /vmlinuz root=/dev/sda2 console=ttyS1,19200n8
Add this line to /etc/initab, if ttyS1 is not already there:
co:2345:respawn:/sbin/agetty ttyS1 19200 vt100
Add this line to /etc/securetty, if ttyS1 is not already there:
ttyS1
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.15 ISOL (ipmiutil sol)
ISOL(8) ISOL(8)
NAME
ipmiutil_sol - an IPMI Serial-Over-LAN Console application
SYNOPSIS
ipmiutil sol [-acdeilorsvwxz -NUPREFJTVY]
DESCRIPTION
This utility starts an IPMI Serial-Over-LAN console session. A Serial-
over-LAN console allows the client to see and modify functions before
the OS boots, such as BIOS setup, grub, etc. This utility uses either
the IPMI LAN 1.5 or 2.0 SOL interface. The 1.5 SOL interface is spe-
cific to Intel BMCs, while any IPMI 2.0 BMC should support 2.0 SOL.
The target system/node must first have these parameters configured
before SOL sessions can be started:
- [BIOS] serial console redirection parameters,
- [IPMI] lan and SOL parameters (see ipmiutil lan or ilan), and
- [OS] For Linux, edit grub.conf, inittab, and securetty parameters.
Be sure that the baud rate matches in all of the above places. See the
ipmiutil UserGuide section 4.8 for details.
OPTIONS
-a Activate the SOL Console session, and enter console mode. Use
the escape sequence (’~.’) to exit the session.
-c ’^’ Set the escape Character to ’^’, or another ANSI character.
This changes the default two-character escape sequence (’~.’) to
the specified single escape character, which will end the SOL
session.
-d Deactivate the SOL Console session. Use this if the previous
session was aborted abnormally and starting a new session gives
an error.
-e Turn Encryption off in negotiation when activating a session.
By default, encryption is on for Serial-Over-LAN console ses-
sions.
-l Use Legacy BIOS mapping for Enter key (CR+LF) instead of just
LF. This is needed for BIOS Setup menus and DOS, but causes an
extra LF to occur in Linux. So, only use this option if doing
BIOS or DOS changes. This should be seldom be needed since now
the default is to automatically detect these menus with colored
backgrounds and change the mapping.
-i input_file
Use this file as an input script. The input_file will be read
after the session is established. This can be used to automate
certain tasks. The input_file is read one line at a time. If
the input_file does not have an escape character (~) to end the
session, then the input is returned to the keyboard when the
file ends.
-o output_file
Use a Trace log. The output_file is created and all SOL screen
output is written to the file, including VT100 escape sequences.
If the output_file exists, the output is appended to it. This
can be used to log what the user has done in an SOL session.
-r Use Raw terminal I/O instead of custom VT100 to ANSI translation
(in Windows). Use this option if the server is configured in
BIOS and BMC for ANSI and the utility is being invoked from Win-
dows.
-s NNN For a slow link with high latency, this adds a delay of NNN
microseconds between sending and receiving SOL packets. The
default is 100 microseconds.
-w (Windows only) Do not use the Windows Console buffer, but use
Windows stdio instead. This does not handle cursor positioning
correctly in some cases, however.
-v log_file
Causes debug messages to be displayed to the specified debug
log_file. The default log_file is isoldbg.log in the current
directory.
-x Causes debug messages to be displayed to the debug log file.
-z Causes more verbose debug messages to be displayed to the debug
log file.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any supported
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
EXAMPLES
ipmiutil sol -a -N nodename -U username -P password
Starts an SOL console session to the nodename. Detect the lan proto-
col.
ipmiutil sol -a -N nodename -U username -P password -Flan2
Starts an SOL console session to the nodename. Force lan protocol to
2.0.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8)
iserial(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.16 IWDT (ipmiutil wdt)
IWDT(8) IWDT(8)
NAME
ipmiutil_wdt- display and set WatchDog Timer parameters
SYNOPSIS
ipmiutil wdt [-acdelrtx -N node -P/-R pswd -U user -EFJTVY]
DESCRIPTION
ipmiutil wdt is a program that uses IPMI commands to display and set
WatchDog Timer parameters.
This utility can use either any available IPMI driver, or direct user-
space IOs, or the IPMI LAN interface if -N.
This utility is an example of how to access the IPMI watchdog parame-
ters directly, which allows changing the timer configuration.
There is an init script provided with ipmiutil to automate the task of
managing the watchdog timer in user-space.
# chkconfig --add ipmiutil_wdt (skip this if no chkconfig)
# /etc/init.d/ipmiutil_wdt start
This sets the watchdog timer to reset the system if the wdt is not
restarted within 90 seconds. It creates an /etc/cron.d/wdt file to
restart wdt every 60 seconds. See also ipmiutil UserGuide section 4.4
for more information.
OPTIONS
Command line options are described below.
-a N Set watchdog event Action to N. Values: 0 = No action, 1 = Hard
Reset(default), 2 = Power down, 3 = Power cycle.
-c Show watchdog output in a canonical format, with a default
delimiter of '|'.
-d Disables the watchdog timer.
-e Enables the watchdog timer. The timer is not actually started,
however, until the timer is reset. The pre-timeout action is
not enabled.
-l Set the watchdog dontLog bit to not log watchdog events in the
SEL.
-p N Set watchdog Pretimeout event action to N. Values: 0 = No
action(default), 1 = SMI, 2 = NMI, 3 = Messaging Interrupt. If
this is set to an action other than 0, the pretimeout will also
be set to 90% of the timeout. However, if the timeout is less
than 20 seconds, the pretimeout will not be enabled.
-q S Set watchdog pretimeout value to S seconds, rather than 90% of
the timeout as in -p. The pretimeout value must be >= 5 and at
least 5 seconds less than the timeout value.
-r Resets the watchdog timer. This should be done every N seconds
if the timer is running to prevent the watchdog action (usually
a system reset) from occurring.
-tN Set the watchdog Timeout to N seconds. The default is 120 sec-
onds (2 minutes).
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
SEE ALSO
ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8) ifirewall(8)
ifru(8) ifruset(8) ifwum(8) igetevent(8) ihealth(8) ihpm(8) ilan(8)
ipicmg(8) ireset(8) isel(8) isensor(8) iserial(8) isol(8) isunoem(8)
iwdt(8) ipmiutil(8) ipmi_port(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.17 IFRUSET (ifruset)
IFRUSET(8) IFRUSET(8)
NAME
ifruset - show/set Field Replacable Unit configuration data
SYNOPSIS
ifruset [-bcimx -unpvsafo -N node -U user -P/-R pswd -EFJTVY]
DESCRIPTION
ifruset is a program that uses IPMI commands to show FRU configuration
data and optionally write any Product area fields into the FRU data.
Setting the FRU Product area fields is a function that might be done by
a manufacturer or system integrator. This utility can use either the
/dev/ipmi0 driver from OpenIPMI, the /dev/imb driver from Intel, the
/dev/ipmikcs driver from valinux, direct user-space IOs, or the IPMI
LAN interface if -N.
This program is not built or installed by default. Integrators who
wish to use it should build ipmiutil from source, then do ’cd util;
make ifruset’.
OPTIONS
Command line options are described below.
-u manuf
This option specifies a product manufacturer string to be writ-
ten to the baseboard FRU Product area field 0. This field can
be any string up to 20 characters. The default is to not modify
this FRU field.
-n name
This option specifies a product name string to be written to the
baseboard FRU Product area field 1. This field can be any
string up to 20 characters. The default is to not modify this
FRU field.
-p partnum
This option specifies a product part number string to be written
to the baseboard FRU Product area field 2. This field can be
any string up to 20 characters. The default is to not modify
this FRU field.
-v prod_ver
This option specifies a product version number string to be
written to the baseboard FRU Product area field 3. The version
number can be any string up to 20 characters. The default is to
not modify this FRU field.
-s serial_num
This option specifies a serial number string to be written to
the baseboard FRU Product area field 4. The serial number can
be any string up to 20 characters. The default is to not modify
this FRU field.
-a asset_string
This option specifies an asset tag string to be written to the
baseboard FRU Product area field 5. The asset tag length is
limited by the existing FRU Product data, but is usually allowed
up to 20 characters. The default is to not modify this FRU
field.
-f fruid
This option specifies a product FRU file ID string to be written
to the baseboard FRU Product area field 6. This field can be
any string up to 20 characters.
-o oem This option specifies a product OEM field string to be written
to the baseboard FRU Product area field 7. This field can be
any string up to 20 characters.
-b Only show the Baseboard FRU data. The default behavior is to
also scan for any SDR FRU data or DIMM SPD data referenced by
the SDRs.
-c Show FRU output in a canonical format, with a default delimiter
of '|'.
-i 00 This option specifies a specific FRU ID to show. The input
value should be in hex (0b, 1a, etc.), as shown from the sensor
SDR output. By default, all FRU IDs that are specified in the
FRU locator SDRs are shown.
-m 002000
Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). This
could be used for PICMG or ATCA blade systems. The trailing
character, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-x Causes eXtra debug messages to be displayed.
-y Ignore the check for FRU size overflow, and update the FRU any-
way.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.18 IPMI_PORT (ipmi_port)
IPMI_PORT(8) IPMI_PORT(8)
NAME
ipmi_port - a daemon to bind RMCP port 623 to prevent portmap from
using it
SYNOPSIS
ipmi_port [-bx]
DESCRIPTION
This ipmi_port service starts and binds port 623, then sleeps forever,
so that the portmap service will not try to reuse port 623, which it
otherwise might try to do. Since the IPMI firmware snoops the NIC
channel and grabs any traffic destined for RMCP port 623, any applica-
tion in the OS which tried to use port 623 would fail.
OPTIONS
Command line options are described below.
-b Background mode. Convert to a daemon and run in background.
Without specifying this option, ipmi_port will run in fore-
ground.
-x Causes eXtra debug messages to be displayed.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) idiscover(8) ievents(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.19 IPICMG (ipmiutil picmg)
IPICMG(8) IPICMG(8)
NAME
ipmiutil_picmg - send specific PICMG extended IPMI commands
SYNOPSIS
ipmiutil picmg [-mixNUPREFJTVY] parameters
DESCRIPTION
This ipmiutil picmg subcommand sends specific PICMG/ATCA extended IPMI
commands to the firmware.
This utility can use either the /dev/ipmi0 driver from OpenIPMI, the
/dev/imb driver from Intel, the /dev/ipmikcs driver from valinux,
direct user-space IOs, or the IPMI LAN interface if -N.
OPTIONS
Command line options are described below.
-i 00 This option specifies a specific FRU ID to show. The input
value should be in hex (0b, 1a, etc.), as shown from the sensor
SDR output. The default FRU ID is zero (0).
-m 002000
Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). This
could be used for PICMG or ATCA blade systems. The trailing
character, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
PARAMETERS
picmg parameters
properties
Get PICMG properties may be used to obtain and print
Extension major version information, PICMG identifier,
FRU Device ID and Max FRU Device ID.
addrinfo
Get address information. This command may return infor-
mation on the Hardware address, IPMB-0 Address, FRU ID,
Site/Entity ID, and Site/Entity Type.
frucontrol fru id options
Set various control options:
0x00 - Cold Reset
0x01 - Warm Reset
0x02 - Graceful Reboot
0x03 - Issue Diagnostic Interrupt
0x04 - Quiesce [AMC only]
0x05-0xFF - Cold Reset
activate fru id
Activate the specified FRU.
deactivate fru id
Deactivate the specified FRU.
policy get fru id
Get FRU activation policy.
policy set fru id lockmask lock
Set FRU activation policy. lockmask is 1 or 0 to indi-
cate action on the deactivation or activation locked bit
respectively. lock is 1 or 0 to set/clear locked bit.
portstate set|getall|getgranted|getdenied parameters
Get or set various port states. See usage for parameter
details.
EXAMPLES
ipmiutil picmg properties
Gets PICMG properties from the default target address (slave address
0x20).
ipmiutil picmg -N 192.168.1.1 -U root -P pswd addrinfo
Gets PICMG Address Information from the specified IP address.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) idiscover(8) ievents(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.20 IFIREWALL (ipmiutil firewall)
IFIREWALL(8) IFIREWALL(8)
NAME
ipmiutil_firewall - configure the IPMI firmware firewall functions
SYNOPSIS
ipmiutil firewall [-mxNUPREFJTVY] parameters
DESCRIPTION
This ipmiutil firewall command supports the IPMI Firmware Firewall
capability. It may be used to add or remove security-based restric-
tions on certain commands/command sub-functions or to list the current
firmware firewall restrictions set on any commands. For each firmware
firewall command listed below, parameters may be included to cause the
command to be executed with increasing granularity on a specific LUN,
for a specific NetFn, for a specific IPMI Command, and finally for a
specific command’s sub-function. See Appendix H in the IPMI 2.0 Speci-
fication for a listing of any sub-function numbers that may be associ-
ated with a particular command.
This utility can use either the /dev/ipmi0 driver from OpenIPMI, the
/dev/imb driver from Intel, the /dev/ipmikcs driver from valinux,
direct user-space IOs, or the IPMI LAN interface if -N.
OPTIONS
Command line options are described below.
-m 002000
Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). This
could be used for PICMG or ATCA blade systems. The trailing
character, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
PARAMETERS
Parameter syntax and dependencies are as follows:
firewall [channel H] [lun L [ netfn N [command C [subfn S]]]]
Note that if "netfn N" is specified, then "lun L" must also be speci-
fied; if "command C" is specified, then "netfn N" (and therefore "lun
L") must also be specified, and so forth.
"channel H" is an optional and standalone parameter. If not specified,
the requested operation will be performed on the current channel. Note
that command support may vary from channel to channel.
Firmware firewall commands:
info [(Parms as described above)]
List firmware firewall information for the specified LUN,
NetFn, and Command (if supplied) on the current or speci-
fied channel. Listed information includes the support,
configurable, and enabled bits for the specified command
or commands.
Some usage examples:
info [channel H] [lun L]
This command will list firmware firewall informa-
tion for all NetFns for the specified LUN on
either the current or the specified channel.
info [channel H] [lun L [ netfn N ]
This command will print out all command informa-
tion for a single LUN/NetFn pair.
info [channel H] [lun L [ netfn N [command C] ]]
This prints out detailed, human-readable informa-
tion showing the support, configurable, and
enabled bits for the specified command on the
specified LUN/NetFn pair. Information will be
printed about each of the command subfunctions.
info [channel H] [lun L [ netfn N [command C [subfn S]]]]
Print out information for a specific sub-func-
tion.
enable [(Parms as described above)]
This command is used to enable commands for a given
NetFn/LUN combination on the specified channel.
disable [(Parms as described above)] [force]
This command is used to disable commands for a given
NetFn/LUN combination on the specified channel. Great
care should be taken if using the "force" option so as
not to disable the "Set Command Enables" command.
reset [(Parms as described above)]
This command may be used to reset the firmware firewall
back to a state where all commands and command sub-func-
tions are enabled.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) idiscover(8) ievents(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.21 IFWUM (ipmiutil fwum)
IFWUM(8) IFWUM(8)
NAME
ipmiutil_fwum - Update IPMC using Kontron OEM Firmware Update Manager
SYNOPSIS
ipmiutil fwum [-mixNUPREFJTVY] parameters
DESCRIPTION
This ipmiutil fwum subcommand updates IPMC firmware using Kontron OEM
Firmware Update Manager.
This utility can use either the /dev/ipmi0 driver from OpenIPMI, the
/dev/imb driver from Intel, the /dev/ipmikcs driver from valinux,
direct user-space IOs, or the IPMI LAN interface if -N.
OPTIONS
Command line options are described below.
-i 00 This option specifies a specific FRU ID to show. The input
value should be in hex (0b, 1a, etc.), as shown from the sensor
SDR output. The default FRU ID is zero (0).
-m 002000
Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). This
could be used for PICMG or ATCA blade systems. The trailing
character, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
PARAMETERS
fwum parameters
info
Show information about current firmware.
status
Show status of each firmware bank present in the hard-
ware.
download filename
Download the specified firmware image.
upgrade [filename]
Install firmware upgrade. If the filename is specified,
the file is downloaded first, otherwise the last firmware
downloaded is used.
rollback
Ask IPMC to rollback to previous version.
tracelog
Show the firmware upgrade log.
EXAMPLES
ipmiutil fwum info
Gets Firmware information
ipmiutil fwum -N 192.168.1.1 -U root -P pswd download firmware.img
Downloads the firmware version contained in firmware.img over IPMI LAN.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) idiscover(8) ievents(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.22 IHPM (ipmiutil hpm)
IHPM(8) IHPM(8)
NAME
ipmiutil_hpm - PICMG HPM.1 Upgrade Agent
SYNOPSIS
ipmiutil hpm [-mxNUPREFJTVY] parameters
DESCRIPTION
This ipmiutil hpm subcommand updates HPM components using PICMG HPM.1
file
This utility can use either the /dev/ipmi0 driver from OpenIPMI, the
/dev/imb driver from Intel, the /dev/ipmikcs driver from valinux,
direct user-space IOs, or the IPMI LAN interface if -N.
OPTIONS
Command line options are described below.
-m 002000
Target a specific MC (e.g. bus 00, sa 20, lun 00). This could
be used for PICMG or ATCA blade systems. The trailing charac-
ter, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
PARAMETERS
hpm parameters
check
Check the target information.
check filename
Display both the existing target version and image ver-
sion on the screen.
download filename
Download specified firmware.
upgrade filename [all] [component x] [activate]
Upgrade the firmware using a valid HPM.1 image file. If
no option is specified, the firmware versions are checked
first and the firmware is upgraded only if they are dif-
ferent.
all
Upgrade all components even if the firmware ver-
sions are the same (use this only after using
"check" command).
component x
Upgrade only given component from the given file.
component 0 - BOOT
component 1 - RTK
activate
Activate new firmware right away.
activate
Activate the newly uploaded firmware.
targetcap
Get the target upgrade capabilities.
compprop id opt
Get the specified component properties. Valid component
id: 0-7. Opt can be one of following:
0 - General properties
1 - Current firmware version
2 - Description string
3 - Rollback firmware version
4 - Deferred firmware version
abort
Abort the on-going firmware upgrade.
upgstatus
Show status of the last long duration command.
rollback
Perform manual rollback on the IPM Controller firmware.
rollbackstatus
Show the rollback status.
selftestresult
Query the self test results.
EXAMPLES
ipmiutil hpm targetcap
Gets HPM target capabilities
ipmiutil hpm -N 192.168.1.1 -U root -P pswd download firmware.img
Downloads the HPM firmware version contained in firmware.img over IPMI
LAN.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) idiscover(8) ievents(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.23 ISUNOEM (ipmiutil sunoem)
ISUNOEM(8) ISUNOEM(8)
NAME
ipmiutil_sunoem - OEM commands for Sun servers
SYNOPSIS
ipmiutil sunoem [-mx -NPRUEFJTVY] commands
DESCRIPTION
ipmiutil sunoem commands is a program that uses Sun OEM IPMI commands
to perform platform-specific functions.
OPTIONS
-m 002000
Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). This
could be used for PICMG or ATCA blade systems. The trailing
character, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
COMMANDS
led
These commands provide a way to get and set the status of LEDs
on a Sun Microsystems server. Use ’sdr list generic’ to get a
list of devices that are controllable LEDs. The ledtype parame-
ter is optional and not necessary to provide on the command line
unless it is required by hardware.
get sensorid [ledtype]
Get status of a particular LED described by a Generic
Device Locator record in the SDR. A sensorid of all will
get the status of all available LEDS.
set sensorid ledmode [ledtype]
Set status of a particular LED described by a Generic
Device Locator record in the SDR. A sensorid of all will
set the status of all available LEDS to the specified
ledmode and ledtype.
LED Mode is required for set operations:
OFF Off
ON Steady On
STANDBY 100ms on 2900ms off blink rate
SLOW 1HZ blink rate
FAST 4HZ blink rate
LED Type is optional:
OK2RM Ok to Remove
SERVICE Service Required
ACT Activity
LOCATE Locate
fan speed 0-100
Set system fan speed (PWM duty cycle).
sshkey
set userid keyfile
This command will allow you to specify an SSH key
to use for a particular user on the Service Pro-
cessor. This key will be used for CLI logins to
the SP and not for IPMI sessions. View available
users and their userids with the ’user list’ com-
mand.
del userid
This command will delete the SSH key for a speci-
fied userid.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8)
iserial(8) isol(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.24 IEKANALYZER (ipmiutil ekanalyzer)
IEKANALYZER(8) IEKANALYZER(8)
NAME
ipmiutil_ekanalyzer - run FRU-Ekeying analyzer with FRU files
SYNOPSIS
ipmiutil ekanalyzer [-mx -NPRUEFJTVY] commands (deprecated, see ifru
instead)
DESCRIPTION
ipmiutil ekanalyzer is a program that analyzes FRU Ekeying information
from files saved from PICMG IPMI systems.
ekanalyzer command xx=filename1 xx=filename2 [rc=filename3]
NOTE: This command can support a maximum of 8 files per command line
filename1
binary file that stores FRU data of a Carrier or an AMC module
filename2
binary file that stores FRU data of an AMC module. These binary
files can be generated from this command:
ipmiutil fru -i id -d filename
filename3
configuration file used for configuring On-Carrier Device ID or
OEM GUID. This file is optional.
xx indicates the type of the file. It can take the following value:
oc : On-Carrier device
a1 : AMC slot A1
a2 : AMC slot A2
a3 : AMC slot A3
a4 : AMC slot A4
b1 : AMC slot B1
b2 : AMC slot B2
b3 : AMC slot B3
b4 : AMC slot B4
sm : Shelf Manager
OPTIONS
-m 002000
Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). This
could be used for PICMG or ATCA blade systems. The trailing
character, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
COMMANDS
The available commands for ekanalyzer are:
print [carrier | power | all]
carrier (default) oc=filename1 oc=filename2 ...
Display point to point physical connectivity between carriers
and AMC modules.
Example:
# ipmiutil ekanalyzer print carrier oc=fru oc=carrierfru
From Carrier file: fru
Number of AMC bays supported by Carrier: 2
AMC slot B1 topology:
Port 0 =====> On Carrier Device ID 0, Port 16
Port 1 =====> On Carrier Device ID 0, Port 12
Port 2 =====> AMC slot B2, Port 2
AMC slot B2 topology:
Port 0 =====> On Carrier Device ID 0, Port 3
Port 2 =====> AMC slot B1, Port 2
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
From Carrier file: carrierfru
On Carrier Device ID 0 topology:
Port 0 =====> AMC slot B1, Port 4
Port 1 =====> AMC slot B1, Port 5
Port 2 =====> AMC slot B2, Port 6
Port 3 =====> AMC slot B2, Port 7
AMC slot B1 topology:
Port 0 =====> AMC slot B2, Port 0
AMC slot B1 topology:
Port 1 =====> AMC slot B2, Port 1
Number of AMC bays supported by Carrier: 2
power xx=filename1 xx=filename2 ...
Display power supply information between carrier and AMC
modules.
all xx=filename xx=filename ...
Display both physical connectivity and power supply of each car-
rier and AMC modules.
frushow xx=filename
Convert a binary FRU file into human readable text format. Use -v
option to get more display information.
summary [match | unmatch | all]
match (default) xx=filename xx=filename ...
Display only matched results of Ekeying match between an On-Car-
rier device and an AMC module or between 2 AMC modules. Example:
# ipmiutil ekanalyzer summary match oc=fru b1=amcB1 a2=amcA2
On-Carrier Device vs AMC slot B1
AMC slot B1 port 0 ==> On-Carrier Device 0 port 16
Matching Result
- From On-Carrier Device ID 0
-Channel ID 11 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet
link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot B1
-Channel ID 0 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet
link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
AMC slot B1 port 1 ==> On-Carrier Device 0 port 12
Matching Result
- From On-Carrier Device ID 0
-Channel ID 6 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet
link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot B1
-Channel ID 1 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet
link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
On-Carrier Device vs AMC slot A2
AMC slot A2 port 0 ==> On-Carrier Device 0 port 3
Matching Result
- From On-Carrier Device ID 0
-Channel ID 9 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet
link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot A2
-Channel ID 0 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet
link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
AMC slot B1 vs AMC slot A2
AMC slot A2 port 2 ==> AMC slot B1 port 2
Matching Result
- From AMC slot B1
-Channel ID 2 || Lane 0: enable
-Link Type: AMC.3 Storage
-Link Type extension: Serial Attached SCSI (SAS/SATA)
-Link Group ID: 0 || Link Asym. Match: FC or SAS interface
{exact match}
- To AMC slot A2
-Channel ID 2 || Lane 0: enable
-Link Type: AMC.3 Storage
-Link Type extension: Serial Attached SCSI (SAS/SATA)
-Link Group ID: 0 || Link Asym. Match: FC or SAS interface
{exact match}
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
unmatch xx=filename xx=filename ...
Display the unmatched results of Ekeying match between an On-
Carrier device and an AMC module or between 2 AMC modules
all xx=filename xx=filename ...
Display both matched result and unmatched results of Ekeying
match between two cards or two modules.
SEE ALSO
ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8) ifirewall(8)
ifru(8) ifruset(8) ifwum(8) igetevent(8) ihealth(8) ihpm(8) ilan(8)
ipicmg(8) ireset(8) isel(8) isensor(8) iserial(8) isol(8) isunoem(8)
iwdt(8) ipmiutil(8) ipmi_port(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.25 ITSOL (ipmiutil tsol)
ITSOL(8) ITSOL(8)
NAME
ipmiutil_tsol - Tyan IPMIv1.5 Serial-Over-LAN Console application
SYNOPSIS
ipmiutil tsol [recvip] [port=NUM] [ro|rw] [rows=NUM] [cols=NUM] [alt-
term]
DESCRIPTION
This command allows Serial-over-LAN sessions to be established with
Tyan IPMIv1.5 SMDC such as the M3289 or M3290. The default command run
with no arguments will establish default SOL session back to local IP
address. Optional arguments may be supplied in any order.
OPTIONS
<recv ipaddr>
Send receiver IP address to SMDC which it will use to send
serial traffic to. By default this detects the local IP
address and establishes two-way session. Format of ipaddr is
XX.XX.XX.XX
port Configure UDP port to receive serial traffic on. By default
this is 6230.
ro|rw Confiure SOL session as read-only or read-write. Sessions
are read-write by default.
rows Set terminal rows [default: rows=24]
cols Set terminal columns [default: cols=80]
altterm
Alternate terminal setup [default is off]
EXAMPLES
ipmiutil tsol 192.168.1.1
Starts a Tyan SOL console session to the IP address.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8)
iserial(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.26 IDELLOEM (ipmiutil delloem)
IDELLOEM(8) IDELLOEM(8)
NAME
ipmiutil_delloem - OEM commands for Dell servers
SYNOPSIS
ipmiutil delloem [-mx -NPRUEFJTVY] commands
DESCRIPTION
ipmiutil delloem commands is a program that uses Dell OEM IPMI commands
to perform platform-specific functions.
OPTIONS
-m 002000
Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). This
could be used for PICMG or ATCA blade systems. The trailing
character, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
COMMANDS
mac list
Lists the MAC address of LOMs
mac get <NIC number>
Shows the MAC address of specified LOM. 0-7 System LOM, 8-
DRAC/iDRAC.
lan set <Mode>
Sets the NIC Selection Mode (dedicated, shared,
shared with failover lom2, shared with Failover all
loms).
lan get
Returns the current NIC Selection Mode (dedicated, shared,
shared with failover lom2, shared with Failover all loms).
lan get active
Returns the current active NIC (dedicated, LOM1, LOM2, LOM3,
LOM4).
powermonitor
Shows power tracking statistics
powermonitor clear cumulativepower
Reset cumulative power reading
powermonitor clear peakpower
Reset peak power reading
powermonitor powerconsumption
Displays power consumption in <watt|btuphr>
powermonitor powerconsumptionhistory <watt|btuphr>
Displays power consumption history
powermonitor getpowerbudget
Displays power cap in <watt|btuphr>
powermonitor setpowerbudget <val> <watt|btuphr|percent>
Allows user to set the power cap in <watt|BTU/hr|percentage>
powermonitor enablepowercap
To enable set power cap
powermonitor disablepowercap
To disable set power cap
windbg start
Starts the windbg session (Cold Reset & SOL Activation)
windbg end
Ends the windbg session (SOL Deactivation)
vFlash info Card
Shows Extended SD Card information
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8)
iserial(8) isol(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.27 IDCMI (ipmiutil dcmi)
IDCMI(8) IDCMI(8)
NAME
ipmiutil_dcmi - handle DCMI functions
SYNOPSIS
ipmiutil dcmi [-admsx -NUPREFTVY] <function>
DESCRIPTION
This ipmiutil dcmi subcommand handles DCMI command functions according
to the DCMI specification.
This utility can use either the /dev/ipmi0 driver from OpenIPMI, the
/dev/imb driver from Intel, the /dev/ipmikcs driver from valinux,
direct user-space IOs, or the IPMI LAN interface if -N.
OPTIONS
Command line options are described below.
-a string
Set the DCMI Asset Tag to this string.
-d string
Set the DCMI MC ID to this string.
-m 002000
Target a specific MC (e.g. bus 00, sa 20, lun 00). This could
be used for PICMG or ATCA blade systems. The trailing charac-
ter, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-s When getting info, also get the DCMI sensor information.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
FUNCTIONS
info Get DCMI Capabilities, MC ID, and Asset Tag. This is the default
function if no function was specified.
power Get DCMI Power reading and DCMI Power limit, if supported in the
DCMI capabilties.
power set_limit
Set Power limit
power set_action <action>
Set Power limit exception action (where action = no_action |
power_off | log_sel)
power set_correction
Set Power limit correction time (in ms)
power set_sample
Set Power limit sampling period (in sec)
power activate
Activate Power limit
power deactivate
Deactivate Power limit
thermal
Get/Set DCMI Thermal parameters. This requires DCMI 1.5 sup-
port.
config Get/Set DCMI Configuration parameters. This requires DCMI 1.5
support.
help Show the help (usage) message
EXAMPLES
ipmiutil dcmi info -s
Gets DCMI information, plus DCMI sensor information
ipmiutil dcmi -N 192.168.1.1 -U root -P pswd
Gets DCMI information over IPMI LAN.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) idiscover(8) ievents(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.28 ISMCOEM (ipmiutil smcoem)
ISMCOEM(8) ISMCOEM(8)
NAME
ipmiutil_smcoem - OEM commands for SuperMicro servers
SYNOPSIS
ipmiutil smcoem [-mx -NPRUEFJTVY] commands
DESCRIPTION
ipmiutil smcoem is a function that uses SuperMicro OEM IPMI commands to
perform platform-specific functions.
OPTIONS
-m 002000
Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). This
could be used for PICMG or ATCA blade systems. The trailing
character, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
COMMANDS
intrusion
This command resets any chassis intrusion condition that may
have occurred.
bmcstatus [enable|disable]
This command gets or sets the BMC service status. Alone, with-
out arguments, it gets the BMC status as either enabled or dis-
abled. With an argument of either enable or disable, it will
also set the BMC status as specified.
firmware
This command gets the extra firmware version information, if
available.
lanport [dedicated|lan1|failover]
This command gets or sets the IPMI LAN interface port. If set
to dedicated, only the dedicated IPMI NIC can be configured for
IPMI LAN. If set to lan1, only the first onboard NIC (LAN1) can
be configured for IPMI LAN. If set to failover, both the dedi-
cated and onboard LAN1 port would be configured for IPMI LAN,
with the same IP address.
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
ifru(8) igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8)
iserial(8) isol(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.29 ISELTIME (iseltime)
ISELTIME(8) ISELTIME(8)
NAME
iseltime - synchronize BIOS RTC and firmware SEL time from system time
SYNOPSIS
iseltime [-sx -N node -U user -P/-R pswd -EFJTVYZ]
DESCRIPTION
iseltime is a program that allows synchronizing the hardware time val-
ues for RTC (BIOS Real-Time-Clock) and SEL (IPMI firmware SEL time)
with the OS system time. Run without options, iseltime shows each of
these times to show whether they are the same or not.
The OS system time should be in sync with the BIOS Real-Time-Clock.
The OS system time may also be kept from drifting via an NTP server.
Normally the BIOS will set the firmware SEL time from the RTC during
boot, but running this command may be necessary periodically if the
system does not reboot for a long time, for instance. Note that some
applications may not handle setting the time backward well. Note that
this command should not be run too frequently to avoid firmware timing
issues. It should not be set more than once per day.
OPTIONS
Command line options are described below.
-s Set the RTC and IPMI firmware SEL time to match the system time.
This should not be performed more often than once a day.
-x Causes eXtra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
-Z Set the slave address for a local MC
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------------------
3.30 IUSER (ipmiutil user)
IUSER(8) IUSER(8)
NAME
ipmiutil_user - handle user functions
SYNOPSIS
ipmiutil user [-cmsx -NUPREFTVY] <function>
DESCRIPTION
This ipmiutil user subcommand handles IPMI LAN user functions sepa-
rately.
These functions can also be handled from ipmiutil lan -q, -u, -p, -v.
This utility can use either the /dev/ipmi0 driver from OpenIPMI, the
/dev/imb driver from Intel, the /dev/ipmikcs driver from valinux,
direct user-space IOs, or the IPMI LAN interface if -N.
OPTIONS
Command line options are described below.
-c Canonical, delimited output format
-m 002000
Target a specific MC (e.g. bus 00, sa 20, lun 00). This could
be used for PICMG or ATCA blade systems. The trailing charac-
ter, if present, indicates SMI addressing if ’s’, or IPMB
addressing if ’i’ or not present.
-s When getting info, also get the DCMI sensor information.
-x Causes extra debug messages to be displayed.
-N nodename
Nodename or IP address of the remote target system. If a node-
name is specified, IPMI LAN interface is used. Otherwise the
local system management interface is used.
-U rmt_user
Remote username for the nodename given. The default is a null
username.
-P/-R rmt_pswd
Remote password for the nodename given. The default is a null
password.
-E Use the remote password from Environment variable IPMI_PASSWORD.
-F drv_t
Force the driver type to one of the followng: imb, va, open,
gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means
lan2 with intelplus. The default is to detect any available
driver type and use it.
-J Use the specified LanPlus cipher suite (0 thru 17):
0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none,
3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40,
6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
-T Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2,
2=MD5, 4=Straight Password, 5=OEM.
-V Use a specified IPMI LAN privilege level. 1=Callback level,
2=User level, 3=Operator level, 4=Administrator level (default),
5=OEM level.
-Y Yes, do prompt the user for the IPMI LAN remote password.
Alternatives for the password are -E or -P.
FUNCTIONS
list [channel]
List the IPMI LAN users with enabled status, privilege level,
and username. Optionally specify a channel number.
enable <user_num> [channel]
Enable the specified user number and optionally specify an IPMI
LAN channel number.
disable <user_num>]
Disable the specified user number, so that it has ’No access’.
set <user_num> name <username>
Set the username for a specified user number.
set <user_num> password <password>
Set the password for a specified user number.
set <user_num> priv <priv_level> [channel]
Set the privilege level for a specified user number, where the
privilege level is 4=Admin, 3=Operator, 2=User. Also optionally
specify a channel number.
help Show the help (usage) message
EXAMPLES
ipmiutil user set 2 name user2
Sets the username for user 2 to "user2".
SEE ALSO
ipmiutil(8) ialarms(8) iconfig(8) idiscover(8) ievents(8) ifru(8)
igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8)
isol(8) iwdt(8)
WARNINGS
See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil
and any bug fix list.
--------------------------
4.0 USE CASES
--------------------------
----------------------------------------------------------------
4.1 Usage of IPMI utilities for sensor thresholds
----------------------------------------------------------------
Get and set the Baseboard Temperature sensor threshold with
the 'sensor' utility like this:
# ipmiutil sensor -t
[...]
000e SDR Full 01 39 20 sensnum 30 Baseboard Temp = 1d OK 29.00 degrees C
hi-crit 65.00 hi-noncr 60.00 lo-noncr 10.00 lo-crit 5.00
[...]
Using sensor number 30, index 000e, and the hex raw reading (1d) as a
baseline from above, we can set the lower threshold above the current
reading, i.e. 0x1e or 30 C.
# ipmiutil sensor -i 0e -t -n 0x30 -l 30
sensor: version 1.39
idx = 0e
-- BMC version 0.48, IPMI version 1.5
_ID_ SDR_Type_xx Sz Own Typ S_Num Sens_Description Hex & Interp Reading
000e SDR Full 01 39 20 sensnum 30 Baseboard Temp = 1d OK 29.00 degrees C
hi-crit 65.00 hi-noncr 60.00 lo-noncr 10.00 lo-crit 5.00
Setting SDR 000e sensor 30 to lo=1e hi=ff
GetThreshold[30]: 30 1b 0a 05 00 3c 41 00
SetThreshold[30]: 30 03 20 1f 1e 00 00 00
SetSensorThreshold[30] to lo=1e(30.000) hi=ff(0.000), ret = 0
#
This sets the lower non-crit to 1e (30 C), and lower crit to 1f (31 C), and
would cause a sensor threshold event. Note that this utility takes the
raw threshold value and increments it sequentially for each of the severities.
Now we should set the lower threshold back to a more normal value of 5 C.
# ipmiutil sensor -i 0e -t -n 0x30 -l 5
sensor: version 1.39
idx = 0e
-- BMC version 0.48, IPMI version 1.5
_ID_ SDR_Type_xx Sz Own Typ S_Num Sens_Description Hex & Interp Reading
000e SDR Full 01 39 20 a 01 snum 30 Baseboard Temp = 1b Crit-lo 27.00 degrees
C
hi-crit 66.00 hi-noncr 60.00 lo-noncr 10.00 lo-crit 5.00
Setting SDR 000e sensor 30 to lo=05 hi=ff
GetThreshold[30]: 30 1b 20 1f 00 3c 42 00
SetThreshold[30]: 30 03 07 06 05 00 00 00
SetSensorThreshold[30] to lo=05(5.000) hi=ff(0.000), ret = 0
#
The threshold events can be displayed via ipmiutil sel.
# ipmiutil sel -l4
4b18 07/17/06 14:33:14 BMC 01 Temperature 30 LoC thresh OK now act=1b thr=06
4b04 07/17/06 14:33:14 BMC 01 Temperature 30 LoN thresh OK now act=1b thr=07
4af0 07/17/06 14:26:38 BMC 01 Temperature 30 Lo Crit thresh act=1b thr=1f
4adc 07/17/06 14:26:38 BMC 01 Temperature 30 Lo Noncrit thresh act=1b thr=20
#
----------------------------------------------------------------
4.2 How to configure a system for IPMI LAN
----------------------------------------------------------------
Below is a sample IPMI LAN configuration with IPMI LAN enabled,
PEF Alerts enabled, and 2 users configured for IPMI LAN.
The key unique LAN parameters that must be configured for basic
IPMI LAN functionality are: 3,4,5,6,12,13, plus the
Channel Access Mode and User Access.
Additional parameters for PEF and SOL are shown below also.
Defaults for required parameters are detected by ipmiutil lan, except
for the username, password, and the BMC LAN IP if it is not shared.
The detection uses the OS LAN configuration to find the gateway IP,
MAC addresses, mask, etc.
# ipmiutil lan -e -u user2 -p password2 [-I 192.168.1.1 ] [-L 3]
Running "ipmiutil lan -e -u user2 -p password2" would set up all required
IPMI LAN parameters if the OS and BMC share an IP address. If not,
the -I parameter should be included to specify the BMC IP.
You may want to add -G [-H] to specify the gateway IP address [gateway MAC]
if the OS does not have a NIC on the same subnet.
To configure an RMM NIC for IPMI LAN, the '-L 3' parameter specifies the
RMM NIC as IPMI LAN channel 3. Otherwise ipmiutil detects the first
available IPMI LAN channel and configures it (usually channel 1).
Note that this also sets up the PEF table for events, but the channel is
not enabled for PEF events unless an Alert destination is specified,
either in snmpd.conf or via -A.
Note that the IPMI LAN protocol works only from remote systems.
The IPMI LAN cannot recognize LAN commands from the local system
because those requests never really go onto the physical network.
Use the non-LAN form of a given ipmiutil command (without -N) to run locally.
Below is sample output from a system after being configured for IPMI LAN.
# ipmiutil lan
ipmiutil ver 2.71
ilan ver 2.71
-- BMC version 0.66, IPMI version 2.0
ilan, GetPefEntry ...
PEFilter(01): 01 Temperature Sensor event - enabled for alert
PEFilter(02): 02 Voltage Sensor event - enabled for alert
PEFilter(03): 04 Fan Failure event - enabled for alert
PEFilter(04): 05 Chassis Intrusion event - enabled for alert
PEFilter(05): 08 Power Supply Fault event - enabled for alert
PEFilter(06): 0c Memory ECC Error event - enabled for alert
PEFilter(07): 0f BIOS POST Error event - enabled for alert
PEFilter(08): 07 FRB Failure event - enabled for alert
PEFilter(09): 13 Fatal NMI event - enabled for alert
PEFilter(10): 23 Watchdog Timer Reset event - enabled for alert
PEFilter(11): 12 System Restart event - enabled for alert
PEFilter(12): 20 OS Critical Stop event - enabled for alert
PEFilter(13): 09 Power Redundancy Lost event - enabled for alert
PEFilter(14): 09 Power Unit OK event - enabled for alert
PEFilter(15): 01 Temperature OK event - enabled for alert
PEFilter(16): 02 Voltage OK event - enabled for alert
PEF Control: 01 : PEFenable
PEF Actions: 2f : Alert PwrDn Reset PwrCyc DiagInt
PEF Startup Delay: 3c : 60 sec
PEF Alert Startup Delay: 3c: 60 sec
PEF Alert Policy[1]: 01 18 11 00 : Chan[1] Dest[1] Enabled
PEF Alert Policy[2]: 02 00 00 00 : Disabled
PEF Alert Policy[3]: 03 00 00 00 : Disabled
PEF Alert Policy[4]: 04 00 00 00 : Disabled
ilan, GetLanEntry for channel 1 ...
Lan Param(0) Set in progress: 00
Lan Param(1) Auth type support: 15 : None MD5 Pswd
Lan Param(2) Auth type enables: 14 14 14 14 00 : MD5 Pswd
Lan Param(3) IP address: 192 168 1 192
Lan Param(4) IP addr src: 01 : Static
Lan Param(5) MAC addr: 00 15 17 8b b4 aa
Lan Param(6) Subnet mask: 255 255 255 0
Lan Param(7) IPv4 header: 1e 00 00
Lan Param(10) BMC grat ARP: 01 : Grat-ARP enabled
Lan Param(11) grat ARP interval: 04 : 2 sec
Lan Param(12) Def gateway IP: 192 168 1 200
Lan Param(13) Def gateway MAC: 00 15 17 8b b4 71
Lan Param(14) Sec gateway IP: 0 0 0 0
Lan Param(15) Sec gateway MAC: 00 00 00 00 00 00
Lan Param(16) Community string: public
Lan Param(17) Num dest: 04
Lan Param(18) Dest type: 01 00 01 00 00
Lan Param(18) Dest type: 02 00 00 00 00
Lan Param(18) Dest type: 03 00 00 00 00
Lan Param(18) Dest type: 04 00 00 00 00
Lan Param(19) Dest address: 01 00 00 [192 168 1 161] 00 07 e9 06 15 31
Lan Param(19) Dest address: 02 00 00 [0 0 0 0] 00 00 00 00 00 00
Lan Param(19) Dest address: 03 00 00 [0 0 0 0] 00 00 00 00 00 00
Lan Param(19) Dest address: 04 00 00 [0 0 0 0] 00 00 00 00 00 00
Lan Param(192) DHCP Server IP: 0 0 0 0
Lan Param(193) DHCP MAC Address: 00 00 00 00 00 00
Lan Param(194) DHCP Enable: 00
Channel(1=lan) Access Mode: 02 04 : Always Avail, PEF Alerts Enabled
ilan, GetSOL for channel 1 ...
SOL Enable: 01 : enabled
SOL Auth: 82 : User
SOL Accum Interval: 04 32 : 20 msec
SOL Retry Interval: 06 14 : 200 msec
SOL nvol Baud Rate: 0a : 115.2k
SOL vol Baud Rate: 00 : nobaud
SOL Payload Support(1): 03 00 15 00 00 00 00 00
SOL Payload Access(1,1): 02 00 00 00 : enabled
SOL Payload Access(1,2): 02 00 00 00 : enabled
SOL Payload Access(1,3): 00 00 00 00 : disabled
SOL Payload Access(1,4): 00 00 00 00 : disabled
Users: showing 4 of max 15 users (2 enabled)
User Access(chan1,user1): 0f 02 01 14 : IPMI, Admin ()
User Access(chan1,user2): 0f 02 01 14 : IPMI, Admin (root)
User Access(chan1,user3): 0f 02 01 0f : No access (admin)
User Access(chan1,user4): 0f 02 01 0f : No access ()
ipmiutil lan, completed successfully
----------------------------------------------------------------
4.3 Usage of IPMI utilities for Automatic IPMI LAN configuration
----------------------------------------------------------------
Suppose there are a number of IPMI servers that need to have their
IPMI LAN interface configured. Shell access to the servers
(via ssh or similar) is assumed.
IPMI LAN, Simple case, password is not changed, default user:
[ssh connection]
# ipmiutil lan -e
[ssh exit]
IPMI LAN, Complex case, assuming that a password needs to be set and
that the session text (or script) must encrypt the password.
Assumes that we are setting a non-default user named 'admin' below.
So, using the gnupg.org utilities with public/private keys
would look something like this:
[ Set up list (or db) of encrypted passwords & key by nodename.
Note that the list and keyfile could reside locally, building
the ssh script syntax, so that only the encrypted password is
exposed remotely. ]
[ssh connection]
# gpg --import mykey.file
# mynode=`uname -n`
# my_enc_psw=`grep $mynode mylist.file |cut -f2`
# ipmiutil lan -e -u admin -p `gpg --decrypt $my_enc_psw`
[ssh exit]
----------------------------------------------------------------
4.4 Usage of IPMI Utilities to Set Watchdog timer
----------------------------------------------------------------
Watchdog timer coverage over the phases of boot and OS operation:
Power-on to end-of-POST = BIOS FRB2
end-of-POST to OS Running = BIOS OS Boot Timeout
OS User-space operation = SMS Timeout via "ipmiutil wdt"
Each of these phases uses the same watchdog timer mechanism but initializes
the timer with different values.
For user-space watchdog control, use "ipmiutil wdt" to read, set, and reset the
IPMI watchdog timer. There is an init script provided with ipmiutil to
automate this task.
# chkconfig --add ipmiutil_wdt (skip this if no chkconfig)
# /etc/rc.d/init.d/ipmiutil_wdt start
This sets the watchdog timer to reset the system if the wdt is not
restarted within 90 seconds. It creates an /etc/cron.d/wdt file to
restart wdt every 60 seconds.
This user-space approach is desirable if you wish the watchdog to expire for
such conditions as out-of-memory or out-of-processes, since the cron job will
start a short process for each invocation. Note that this also does not require additional services or modules to be running all the time.
Note that the device-independent way to start/stop watchdog timers in
Linux is to use the /dev/watchdog interface via the OpenIPMI driver.
For kernel-space watchdog management, you could build a custom kernel with
embedded watchdog support by changing the CONFIG_IPMI_* driver parameters
to =y in the Linux .config (including CONFIG_IPMI_WATCHDOG) and building the
kernel. Then edit grub.conf to start the watchdog with the kernel parameter
"ipmi_watchdog_start_now=1".
----------------------------------------------------------------
4.5 Usage of kernel panic handler code (now CONFIG_IPMI_PANIC_EVENT):
----------------------------------------------------------------
If a Linux panic occurs, the bmc_panic module will automatically save
the date/time of the panic, and minimal information about the panic.
This information will also be sent via SNMP to the remote management console,
and (if bmcpanic.patch) the Alarms panel LED will be turned on.
If lkcd is also configured, a full crash-dump of the panic will be saved
for later analysis.
After this, the system will automatically reboot.
This provides instant notification to the administrator, and significantly
improved post-mortem diagnosis.
Without these features, the administrator may never have any indication that
the system had crashed, and no way to know how to diagnose and fix the problem.
To enable this, set CONFIG_IPMI_PANIC_EVENT=y and CONFIG_IPMI_PANIC_STRING=y
in the kernel .config file.
You can also run ipmiutil lan to enable sending an SNMP trap for a kernel
panic as an "OS Critical Stop" event.
Make sure that the panic timeout is not zero (infinite), by using
echo "5" > /proc/sys/kernel/panic
or by adding 'append="panic=5"' to the lilo or grub configuration.
After a panic occurs, you can then use ipmiutil sel to view the firmware
SEL for that event. It should look something like this:
# ipmiutil sel
[...]
2d04 07/21/04 07:54:22 SMI 20 OS Critical Stop 46 (Fat) 6f [a1 61 74]
2d18 OEM Event 20 00 Fatal excep
2d2c OEM Event 20 01 tion
[...]
----------------------------------------------------------------
4.6 Interpreting BMC LAN SNMP Traps from Platform Events.
----------------------------------------------------------------
There are MIB files provided for BMC LAN SNMP traps with this project.
They are installed into /usr/share/ipmiutil/bmclan*.mib, and sym-linked
into /usr/share/snmp/mibs/.
The Platform Event Traps (enterprises.3183) are defined in bmclanpet.mib.
The Alert-on-LAN traps (enterprises.3183) are defined in bmclanaol.mib.
Note that Plaform Event Traps also have a 46-byte binary variable bindings
field included with the trap.
See Section 12.5 and 12.6 from the Intel ISM 5.x TPS for background.
Actual PET Trap Data from a System Restart Event trap:
snmputil: trap generic=6 specific=1208065
from -> 10.243.42.197
Variable = .iso.org.dod.internet.private.enterprises.3183.1.1.1
Value = String <0xa4><0x12><0x00><0x5f><0x62><0xa1><0xd5><0x11><0x00><0x80><0x60><0xff><0x94><0x47><0x03><0x00><0x21><0x19><0x0c><0x7f><0x3b><0x12><0xff><0xff><0x20><0x20><0x00><0x01><0x83><0x00><0x00><0x01><0xff><0xff><0x00><0x00><0x00><0x00><0x00><0x19><0x00><0x00><0x01><0x57><0x00><0x0c><0xc1>
Byte Mapping
Bytes of the trap variable binding data are mapped.
An extra byte of data is at the end (47).
Byte Data Meaning
1 0xa4 System GUID (16 bytes)
2 0x12
3 0x00
4 0x5f
5 0x62
6 0xa1
7 0xd5
8 0x11
9 0x00
10 0x80
11 0x60
12 0xff
13 0x94
14 0x47
15 0x03
16 0x00
17 0x21 Sequence Number/Cookie (2 bytes)
18 0x19
19 0x0c Local Timestamp (4 bytes)
20 0x7f
21 0x3b
22 0x12
23 0xff UTC Offset (2 bytes)
24 0xff
25 0x20 Trap Source Type
26 0x20 Event Source Type
27 0x00 Event Severity
28 0x01 Sensor Device
29 0x83 Sensor Number
30 0x00 Entity
31 0x00 Entity Instance
32 0x01 Event Data (8 bytes max, 3 bytes used)
33 0xff
34 0xff
35 0x00
36 0x00
37 0x00
38 0x00
39 0x00
40 0x19 filler byte
41 0x00 Manufacturer ID (4 bytes, 000157=Intel)
42 0x00
43 0x01
44 0x57
45 0x00 Product ID (2 bytes)
46 0x0c
47 0xc1 extra byte
Also, there is an optional "Extended Platform Event Trap" format defined
for IPMI which breaks up the 46-byte binary varbind into separate
varbinds for easier parsing.
See section 4.10 for how to use ipmiutil to perform the configuration and interpretation of IPMI PET traps. For example, the above trap would be interpreted as follows:
# events -p 00 80 60 ff 94 47 03 00 21 19 0c 7f 3b 12 ff ff 20 20 00 01 83 00 00 01 ff ff 00 00 00 00 00 19 00 00 01 57 00 0c c1
events version 2.34
0019 08/23/04 11:13:06 BMC 12 System Event #83 OEM System Boot 6f [01 ff ff]
----------------------------------------------------------------
4.7 Interpreting newer PECI sensors for CPU Thermal Margin
----------------------------------------------------------------
The newer CPUs do more monitoring internally rather that using absolute
temperature thresholds from the BMC. The CPU knows best what its
thresholds should be, and the thresholds may be different for different
CPUs. So, there are several IPMI sensors that expose the state of the
CPU temperature via the newer PECI interface.
1) Thermal Margin - A negative value indicating margin to throttling point.
Once margin reaches 0, throttling begins
2) Therm Control % - Reports the percentage of time within a 5.8 second
sliding window during which the processor was throttling
3) VRD Hot - Discrete sensor indicating one of the phases of the processor
VRD circuit on the baseboard has exceeded it's limit. This is not
indicative of CPU - just the VR circuit on the baseboard.
Therm Margin is the one to watch if you want max performance without
throttling. If it reaches 0, you will start losing performance to throttling.
However, the Therm Margin throttling is well in advance of the temperatures
that would cause a CPU ThermTrip condition and shut off the system.
----------------------------------------------------------------
4.8 How to configure a system for IPMI Serial-Over-LAN Console
----------------------------------------------------------------
The Serial-Over-LAN (SOL) console configuration requires
configuring BIOS, BMC/IPMI, and OS parameters.
Intel S5000 motherboards and prior use Serial Port B (ttyS1) for SOL,
but Intel S5500 and most other vendors use Serial Port A (ttyS0).
Enter BIOS Setup for Serial Console Redirection parameters:
(these vary by platform)
Console Redirection = Serial Port A
ACPI Redirection = Disabled
Baud Rate = 19.2K (or 115.2k)
Flow Control = CTS/RTS
Terminal Type = VT100
Legacy Redirection = Enabled or Disabled (optional, for DOS)
Note that the Baud Rate can vary, but it must match in all
locations where it is used (BIOS, IPMI, and Linux).
Some vendors may have OS utilities to change BIOS parameters, for instance,
Intel BIOS would use 'syscfg /bcs COM1 19200 CTS VT100' to do this.
Run this sample command for IPMI LAN & SOL configuration:
ipmiutil lan -e -u user2 -p password2 [-B 115.2k] [-I 192.168.1.1]
Use the -I portion if your BMC does not share a MAC address
with the OS. If not specified, the baud rate defaults to either
19.2k or the baud previously set with "ipmiutil serial", if set.
If there is more than one IPMI LAN channel, the alternate channel
can be configured by adding "-L 3" for channel 3.
---- FOR LINUX SERIAL CONSOLE -----
Edit /boot/grub/grub.conf to:
add "console=ttyS0,19200n8" on the end of the kernel line,
then comment out the "splashimage=" line
and optionally add these lines for grub menu display
serial --unit=0 --speed=19200 --word=8 --parity=no --stop=1
(use --unit=1 if ttyS1)
terminal --timeout=10 serial console
(Adding these two lines sometimes does not timeout and continue
without user interaction using some grub-0.9x versions.)
If using /etc/inittab, edit it to add:
co:2345:respawn:/sbin/agetty -h -L 19200 ttyS0 vt100
If using Ubuntu, RHEL6, or Fedora 11, the /etc/inittab has been replaced by
Upstart, with a different procedure.
If using Upstart (Ubuntu, RHEL6), adding the console=ttyS0,19200n8 in grub
will auto-start everything. Editing the serial init for getty is not
required. However, if you want to use hardware flow control, change the
/etc/init/serial.conf last line to:
exec /sbin/agetty -h -L $SPEED /dev/$DEV vt100-nav
Edit /etc/securetty to add:
ttyS0
Edit $HOME/.bashrc or /etc/bashrc to add:
stty crtscts
Adding "stty crtscts" in your bashrc turns on RTS/CTS flow control
once you are logged in. Otherwise operations with lots of output may
miss some chunks of data. Some Linux distributions do not turn this
on by default.
---- FOR WINDOWS SERIAL CONSOLE -----
To configure Windows for Serial (System Admin Console),
these BOOTCFG.EXE commands manipulate the BOOT.INI for SAC:
BOOTCFG /EMS ON /PORT BIOSSET /ID 1 (Enables SAC)
BOOTCFG /EMS OFF /ID 1 (Disables SAC)
---- FOR FREEBSD SERIAL CONSOLE -----
Open the file /etc/ttys with an editor and set up a line like this:
ttyu0 "/usr/libexec/getty std.19200" vt100 on secure
For more details, see
http://www.freebsd.org/doc/en_US.ISO8859-1/books/handbook/serialconsole-setup.html
---- FOR VMware ESXi SERIAL CONSOLE -----
# Enable tty1Port for serial console as COM2
esxcli system settings kernel set -s tty1Port -v com2
----------------------------------------------------------------
4.9 Using ipmiutil Library APIs for custom programs
----------------------------------------------------------------
The various driver modules and LAN interfaces are included in
libipmiutil.a which is built by "cd util; make libipmiutil.a".
The library is named ipmiutil.lib in Windows.
The library is built by default along with the ipmi_sample application
to show how to use this library. Note that ipmi_sample is linked
with libcrypto.so (option -lcrypto) in order to support the lanplus
interface. Only the SOL console function requires lanplus, all other
functions can use the lan interface, since the IPMI 2.0 firmware is
required to support both lan and lanplus. If the custom program does
not require the lanplus interface, it can be reconfigured without
lanplus by first running './configure --enable-standalone'.
This library provides a common interface to use IPMI commands.
See section 9.0 for more information about the common library APIs.
See util/ipmi_sample.c for an example of how these APIs can be used.
----------------------------------------------------------------
4.10 How to configure a system for SNMP Traps via IPMI PEF rules
----------------------------------------------------------------
The IPMI Platform Event Filter (PEF) actions support sending
SNMP v1 traps from the IPMI firmware when IPMI events occur,
regardless of the state of the OS.
1) Configure the server to send IPMI PET traps.
These can be configured using ipmiutil on the target server
with ipmiutil. This command will enable the PEF rules
for SNMP traps.
# ipmiutil lan -e -I <bmc_ip> -A <alert_ip> [-k] [-a num]
The -k option enables PEF rules for the "OK" or clearing traps
for certain IPMI events.
Note that several SNMP alert destinations can be specified
by using the -a num option, where num=1,2,3,4 (1 is the default).
This enables the following PEF rules:
PEFilter(01): 01 Temperature Sensor event - enabled for alert
PEFilter(02): 02 Voltage Sensor event - enabled for alert
PEFilter(03): 04 Fan Failure event - enabled for alert
PEFilter(04): 05 Chassis Intrusion event - enabled for alert
PEFilter(05): 08 Power Supply Fault event - enabled for alert
PEFilter(06): 0c Memory ECC Error event - enabled for alert
PEFilter(07): 0f BIOS POST Error event - enabled for alert
PEFilter(08): 07 FRB Failure event - enabled for alert
PEFilter(09): 13 Fatal NMI event - enabled for alert
PEFilter(10): 23 Watchdog Timer Reset event - enabled for alert
PEFilter(11): 12 System Restart event - enabled for alert
PEFilter(12): 20 OS Critical Stop event - enabled for alert
PEFilter(13): 09 Power Redundancy Lost event - enabled for alert
PEFilter(14): 09 Power Unit OK event - enabled for alert
PEFilter(15): 01 Temperature OK event - enabled for alert
PEFilter(16): 02 Voltage OK event - enabled for alert
Note that Fan failure events do not have a clearing trap because
a fan failure would usually require removing system power to
physically replace the fan.
The IPMI Platform Event Traps (PET) can then be tested with these steps:
2) On the trap receiver, start the SNMP services.
For Linux, this would be:
Optionally edit /etc/snmp/snmpd.conf for a broader view, e.g.:
view systemview included .1
/etc/init.d/snmpd start
/etc/init.d/snmptrapd start
3) On the server under test, cause an event by:
a) removing and reinserting a power supply, or
b) setting the temperature thresholds out of range:
ipmiutil sensor -n 20 -t -h 15
(sets the Baseboard Temp high threshold to 15 degrees C)
then setting the temperature thresholds back to normal:
ipmiutil sensor -n 20 -t -h 61
(sets the Baseboard Temp high threshold to 61 degrees C)
c) you can see the IPMI events generated by doing:
ipmiutil sel
The IPMI PET traps (enterprises.3183) are defined in
/usr/share/ipmiutil/bmclanpet.mib, and the alert destination system
(trap receiver) can interpret them with the ipmiutil events utility
as follows:
4) Get the sensor output from a server of the same type.
Copy /usr/share/ipmiutil/sensor_out.txt to the system where the
traps are received. This would not be required if the trap receiver
and server are both the same type.
5) Get the hex data bytes from the IPMI PET trap.
This sample was taken from /var/log/messages on a Linux system with snmptrapd:
Sep 26 11:22:17 chapin1 snmptrapd[19859]: 2008-09-26 11:22:17 ac1-tigw1u-bmc [10.243.42.235] (via 10.243.42.235) TRAP, SNMP v1, community public SNMPv2-SMI::enterprises.3183.1.1 Enterprise Specific Trap (65792) Uptime: 141 days, 11:37:06.13 SNMPv2-SMI::enterprises.3183.1.1.1 = Hex-STRING: B1 D8 4F 76 1D E2 11 DC B3 E8 00 0E 0C C7 1B A0 11 08 14 31 D3 D4 FF FF 20 20 10 20 30 53 44 50 2B 30 00 00 00 00 00 19 00 00 01 57 08 11 C1
6) Skip the first 8 hex bytes from the hex data above and pass the data to
the ipmiutil events application.
# sfil=/usr/share/ipmiutil/sensor_out.txt
# ipmiutil events -p -s $sfil B3 E8 00 0E 0C C7 1B A0 11 08 14 31 D3 D4 FF FF 20 20 10 20 30 53 44 50 2B 30 00 00 00 00 00 19 00 00 01 57 08 11 C1
events version 2.34
000b SDR Full 01 01 20 a 01 snum 30 Baseboard Temp
0008 09/26/08 04:50:12 BMC 01 Temperature #30 Lo Noncrit thresh act=2b thr=30
This output should match the output from 'ipmiutil sel' on the server.
See also section 4.6 for the format of the IPMI PET data.
----------------------------------
5.0 IPMI UTILITIES ON WINDOWS
----------------------------------
Sample file contents of the ipmiutil win32/64 zip archive:
README.txt - Information about the archive, with install instructions
LICENSE.txt - the BSD license
UserGuide.txt - the ipmiutil User Guide
ChangeLog.txt - change history
install.cmd - INSTALL ipmiutil
uninstall.cmd - UNINSTALL ipmiutil
ipmiutil.exe - meta-command for all of the functions
ipmiutil_wdt.cmd - automatically resets the watchdog timer
checksel.cmd - automatically checks the SEL for nearly full
ialarms.cmd - shortcut for ipmiutil alarms
icmd.cmd - shortcut for ipmiutil cmd
iconfig.cmd - shortcut for ipmiutil config
idiscover.cmd - shortcut for ipmiutil discover
ievents.exe - shortcut for ipmiutil events
ifru.cmd - shortcut for ipmiutil fru
igetevent.cmd - shortcut for ipmiutil getevent
ihealth.cmd - shortcut for ipmiutil health
ilan.cmd - shortcut for ipmiutil lan
isensor.cmd - shortcut for ipmiutil sensor
iserial.cmd - shortcut for ipmiutil serial
isel.cmd - shortcut for ipmiutil sel
isol.cmd - shortcut for ipmiutil sol
ireset.cmd - shortcut for ipmiutil reset
iwdt.cmd - shortcut for ipmiutil wdt
showsel.reg - to add showsel DLL to registry
showselun.reg - to remove showsel DLL from registry
showselmsg.dll - DLL for System Log IPMI messages
libeay32.dll - from openssl crypto
ssleay32.dll - from openssl crypto
buildsamp.cmd - to build the sample programs
ipmiutil.dll - use this with the static library
ipmiutil.lib - static library with ipmiutil functions
ipmiutillib.dll - Use this for dynamic DLL
ipmiutillib.lib - link this into samples to use dynamic DLL
ipmiutillib.exp - exported list of ipmiutil functions
ipmi_sample.exe - sample application
ipmi_sample_evt.exe - sample application with eventing
The install and build instructions are below, all other information
in the UserGuide.txt is the same for Windows and Linux.
----------------------------------
5.1 WINDOWS INSTALL INSTRUCTIONS
----------------------------------
If installing from an MSI file, just double-click to run the install wizard.
If installing from the ZIP file, just run install.cmd.
Otherwise, these are the manual steps to perform.
The showselmsg.dll needs to be copied into the %SystemRoot%\System32
directory and then run showsel.reg, so that the Windows EventLog service
can find information about the showsel events.
Note that the openssl crypto libraries (libeay32.dll and ssleay32.dll)
should be copied to %SystemRoot%\System32 to provide crypto functions
for the lanplus logic, if they are not already present.
For WinPE 64-bit, or other variants without openssl, see also
http://www.indyproject.org/Sockets/fpc/OpenSSLforWin64.en.aspx
Note that for Windows Vista/7 workstation and later, make sure to
'Run as administrator' when installing. Windows Server should not
require this step.
The utilities can be run separately, or an ipmiutil directory can be
added into the %PATH%.
If using the ipmiutil*.msi, it will automatically install.
If using the ipmiutil*.zip, then run the install.cmd to install it.
The usage of ipmiutil in Windows is the same as in Linux OS, with the
exception of drivers:
* The Intel IPMI driver supported is the Intel IMB driver (imbdrv.sys),
which can be obtained from the Intel Resource CD for your system,
from the ISM CD, or from http://www.intel.com by searching downloads
for IMB driver.
http://downloadfinder.intel.com/scripts-df-external/Product_Search.aspx?Prod_nm=imb+driver
or cached at http://ipmiutil.sf.net/kern/imbdrv130.zip
* The Microsoft IPMI driver (ipmidrv.sys), which comes with Windows 2003 R2
and later, is also supported.
It should be noted that the two IPMI drivers should not be installed at the
same time, since they will interfere with each other.
Note that there are several outstanding bug reports against the Microsoft ipmidrv.sys driver which may affect its usage:
* ipmidrv.sys does not support systems with 4-byte register spacing
https://social.technet.microsoft.com/forums/windowsserver/en-US/223e3a0d-3daa-4141-9c13-3169f766a7d5/win2008-ipmidrvsys-does-not-load-if-register-spacing-4
* ipmidrv.sys WBEM access memory leak
https://sourceforge.net/p/ipmiutil/support-requests/11/
https://social.msdn.microsoft.com/Forums/windowsdesktop/en-US/ca4df181-7fd4-4912-83a0-5896b030e3ca/latest-version-of-microsoft-ipmi-driver-ipmidrvsys?forum=wdk
* ipmidrv.sys with Windows 2012 does not work on many IPMI systems
This version is more broken than the Win2008 version.
If you are affected by any of these issues, you can download and install the imbdrv.sys as described below, but you must also disable the MS ipmidrv.sys.
For some systems or applications, you may need to uninstall the Microsoft
IPMI driver, like this:
* start Control Panel/System app
* go to Hardware tab, start Device Manager
* select View/Show Hidden Devices
* go to "System Devices",
* right-click "Microsoft Generic IPMI Compliant Device"
* select Properties
* on driver tab, click "Uninstall"
* then reboot.
If you are running Windows 2012, the Device Manager does not support this,
so use these steps to disable the Microsoft IPMIDRV:
* Start a command prompt with 'Run as administrator'
* cd \windows\system32\drivers
* move ipmidrv.sys ipmidrv.old
* then reboot
How to install Intel IPMI driver from the cached copy at http://ipmiutil.sf.net/kern/imbdrv130.zip
Extract imbdrv130.zip to c:\temp or similar
> cd c:\temp
> cd x86_64 (or 'cd ia32' if 32-bit Windows)
> install.bat (DeviceSetup.exe install imbdrv.inf *IMBDRV)
> driverquery (shows the drivers currently installed/running)
How to install the Windows Intel IPMI driver (imbdrv.sys from the Intel CD):
> cd c:\temp
> copy d:\ism\software\win32\pi\common\imb*.*
> copy d:\ism\software\win32\pi\common\win2k*.exe
> ren imbdrv2k.sys imbdrv.sys
> copy imbapi.dll %SystemRoot%\system32
> win2kinstall c:\temp\imbdrv.inf *IMBDRV
> driverquery (shows the drivers currently installed/running)
Note that when using 32-bit binaries on 64-bit Windows Server installations,
make sure that the Microsoft VC++ Redistributable package is installed
(vcredist_x86.exe).
See http://www.microsoft.com/downloads/details.aspx?familyid=200B2FD9-AE1A-4A14-984D-389C36F85647&displaylang=en
to download this if needed.
----------------------------------
5.2 WINDOWS BUILD INSTRUCTIONS
----------------------------------
The ipmiutil Windows binaries for each release are pre-built and posted
at http://ipmiutil.sourceforge.net, but here is how to build the ipmiutil
EXEs for Windows from source.
Note that the WIN32 compile flag is used.
The ipmiutil buildwin.cmd shows how to compile and link the lib and exe
files, although many people prefer instead to do builds with the
Microsoft VisualStudio project GUI.
5.2.1 Install Visual Studio
The build environment assumes that VisualStudio 6.0 VC98 or
later is installed.
5.2.2 Download contrib files
Before running buildwin.cmd, first download the contributed
files for Windows (includes getopt.c and openssl).
A copy of these files is available from
http://ipmiutil.sf.net/FILES/ipmiutil-contrib.zip
The above zip contains all of the contributed source used.
Refer to getopt.c from one of these
BSD getopt.c (used by default in ipmiutil.exe):
http://www.openmash.org/lxr/source/src/getopt.c?c=gsm
public domain getopt.c:
http://www.koders.com/c/fid034963469B932D9D87F91C86680EB08DB4DE9AA3.aspx
GNU LGPL getopt.c:
http://svn.xiph.org/trunk/ogg-tools/oggsplit/
Refer to openssl from this link (Apache-style license, not gpl)
http://www.openssl.org/source/openssl-0.9.8x.tar.gz (used by default)
5.2.3 Copy initial contrib files into ipmiutil
Below are sample directories where ipmiutil*.tar.gz was unpacked,
and where the openssl*.tar.gz was unpacked.
> set ipmiutil_dir=c:\dev\ipmiutil
> set openssl_dir=c:\dev\openssl
First, copy the getopt.c & getopt.h into the util directory.
From the directory where ipmiutil-contrib.zip was unpacked,
> copy getopt.* %ipmiutil_dir%\util
The iphlpapi.lib comes from Visual Studio (2003 .Net), Win2003 DDK, or WinSDK.
> copy iphlpapi.lib %ipmiutil_dir%\lib
> copy iphlpapi.h %ipmiutil_dir%\util
5.2.4 Build the openssl libraries
To build from original source you would then want to build a copy of openssl
for Windows, and copy the built openssl files to lib & inc.
Follow the openssl build instructions from INSTALL.W32 for VC++ to build
these binaries.
5.2.5 Copy the resulting LIB and DLL binaries to ipmiutil
> copy %openssl_dir%\out32dll\libeay32.lib %ipmiutil_dir%\lib
> copy %openssl_dir%\out32dll\ssleay32.lib %ipmiutil_dir%\lib
> copy %openssl_dir%\out32dll\libeay32.dll %ipmiutil_dir%\util
> copy %openssl_dir%\out32dll\ssleay32.dll %ipmiutil_dir%\util
> mkdir %ipmiutil_dir%\lib\lanplus\openssl
> copy %openssl_dir%\include\openssl\*.h %ipmiutil_dir%\lib\lanplus\openssl
5.2.6 Set the Visual Studio variables with vcvars*.bat
For your installation of Microsoft Visual Studio, it has batch files to
set the Visual C variables. Run the appropriate architecture version of
these batch files to set the VC variables.
Example:
C:\Program Files (x86)\Microsoft Visual Studio 9.0\VC\vcvarsall.bat
or
C:\Program Files (x86)\Microsoft Visual Studio 9.0\VC\bin\vcvars32.bat
or
C:\Program Files (x86)\Microsoft Visual Studio 9.0\VC\bin\amd64\vcvarsamd64.bat
5.2.7 For Windows builds, run buildwin.cmd
buildwin.cmd will build all of the Windows EXE and DLL files. It will detect
whether the vcvars has been run with 32bit or 64bit.
buildwin32.cmd will build only the 32-bit Windows EXE and DLL files.
buildwin64.cmd will build only the 64-bit Windows EXE and DLL files.
5.2.8 For WinPE builds, run buildmin.cmd
If you are using ipmiutil for a bootable WinPE environment, you will not need
Serial-Over-LAN functionality, the buildmin.cmd will build the Windows ipmiutil
EXE files without using the openssl libraries, to simplify the process.
The openssl libraries are required for the IPMI LANplus 2.0 crypto functions
that Serial-Over-LAN uses.
buildmin.cmd will build the ipmiutil.exe in a minimal standalone configuration.
For WinPE 64-bit, if you do want openssl for some reason, see
http://www.indyproject.org/Sockets/fpc/OpenSSLforWin64.en.aspx
----------------------------------
5.3 WINDOWS COMMAND USAGE
----------------------------------
Because of the differences in Linux getopt and the BSD getopt.c used by
default in the Windows build, the order of parameters is more important
in Windows.
For example in Linux, the following command usages work, but not in Windows:
# ipmiutil cmd 00 20 18 01 -N 192.168.1.154
# ipmiutil cmd 00 20 -N 192.168.1.154 18 01
The Windows equivalent would have to put the -N option immediately after
the subfunction, as shown below:
> ipmiutil cmd -N 192.168.1.154 00 20 18 01
For Serial-Over-Lan console usage from a Windows client, ipmiutil provides:
- Full ANSI (VT100) Support
- Full Support for PC Keyboard
- Unicode (UTF-8) support
- Full support for Line Drawing Characters
(VT100 Special Graphics, Unicode Box Characters and OEM CP Characters)
- Full Screen works for BIOS and Unix (using vt100 terminfo setting)
For proper operation during BIOS setup the Windows console window size must be set to 80x25. The Windows console buffer size can be set to the desired scroll back size. For proper operation when logged on to Unix the windows size can be set to anything but the OS must be told of the proper size using "stty rows <height> cols <width>".
--------------------------
6.0 SAMPLE OUTPUT
--------------------------
Below is sample ipmiutil output from an Intel TIGW1U server.
# ipmiutil alarms
ipmiutil ver 2.13
alarms ver 2.13
-- BMC version 0.19, IPMI version 2.0
Alarm LEDs: critical = off major = off minor = off power = off
Alarm Relays: major = off minor = off
disk slot 0 LED: off
disk slot 1 LED: off
disk slot 2 LED: off
disk slot 3 LED: off
disk slot 4 LED: off
disk slot 5 LED: off
alarms, completed successfully
# ipmiutil cmd 00 20 18 01
ipmiutil ver 2.21
icmd ver 2.21
This is a test tool to compose IPMI commands.
Do not use without knowledge of the IPMI specification.
-- BMC version 0.19, IPMI version 2.0
respData[len=15]: 20 01 00 19 02 9f 57 01 00 11 08 00 48 00 16
send_icmd ret = 0
icmd, completed successfully
# ipmiutil config -s /tmp/bmcconfig.out
ipmiutil ver 2.21
bmcconfig ver 1.1
-- BMC version 0.19, IPMI version 2.0
### bmcconfig, GetPefEntry ...
### bmcconfig, GetLanEntry for channel 1 ...
### bmcconfig, GetSOL for channel 1 ...
### bmcconfig, GetSerEntry for channel 4 ...
bmcconfig, completed successfully
# cat /tmp/bmcconfig.out
PEFParam 6,01: 01 c0 01 01 10 ff ff 01 ff 01 95 0a 00 00 00 00 00 00 00 00 00
PEFParam 6,02: 02 c0 01 01 10 ff ff 02 ff 01 95 0a 00 00 00 00 00 00 00 00 00
PEFParam 6,03: 03 c0 01 01 08 ff ff 04 ff 01 95 0a 00 00 00 00 00 00 00 00 00
PEFParam 6,04: 04 c0 01 01 08 ff ff 05 05 6f 01 00 00 00 00 00 00 00 00 00 00
PEFParam 6,05: 05 c0 01 01 08 ff ff 08 ff 6f 06 00 00 00 00 00 00 00 00 00 00
PEFParam 6,06: 06 c0 01 01 10 ff ff 0c 08 6f 02 00 00 00 00 00 00 00 00 00 00
PEFParam 6,07: 07 c0 01 01 08 ff ff 0f 06 6f 01 00 00 00 00 00 00 00 00 00 00
PEFParam 6,08: 08 c0 01 01 10 ff ff 07 ff 6f 1c 00 00 00 00 00 00 00 00 00 00
PEFParam 6,09: 09 c0 01 01 02 ff ff 13 ff 6f 3e 03 00 00 00 00 00 00 00 00 00
PEFParam 6,10: 0a c0 01 01 01 ff ff 23 03 6f 0e 00 00 00 00 00 00 00 00 00 00
PEFParam 6,11: 0b c0 01 01 01 ff ff 12 ff 6f 02 00 00 00 00 00 00 00 00 00 00
PEFParam 6,12: 0c 80 01 01 10 ff ff 20 ff 6f ff 00 00 00 00 00 00 00 00 00 00
PEFParam 6,13: 0d 80 01 01 08 ff ff 09 ff 0b 02 00 00 00 00 00 00 00 00 00 00
PEFParam 6,14: 0e 80 01 01 04 ff ff 09 ff 0b 01 00 00 00 00 00 00 00 00 00 00
PEFParam 6,15: 0f 80 01 01 04 ff ff 01 ff 81 95 0a 00 00 00 00 00 00 00 00 00
PEFParam 6,16: 10 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
PEFParam 6,17: 11 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
PEFParam 6,18: 12 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
PEFParam 6,19: 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
PEFParam 6,20: 14 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
PEFParam 1: 01
PEFParam 2: 2f
PEFParam 3: 3c
PEFParam 4: 3c
PEFParam 9,1: 01 18 11 00
PEFParam 9,2: 02 00 00 00
PEFParam 9,3: 03 00 00 00
PEFParam 9,4: 04 00 00 00
LanParam 0,0: 00
LanParam 1,0: 15
LanParam 2,0: 14 14 14 14 00
LanParam 3,0: 0a f3 2a eb
LanParam 4,0: 01
LanParam 5,0: 00 0e 0c c7 1b a2
LanParam 6,0: ff ff ff 00
LanParam 7,0: 40 40 10
LanParam 10,0: 01
LanParam 11,0: 04
LanParam 12,0: 0a f3 2a fb
LanParam 13,0: 00 d0 06 21 eb fc
LanParam 14,0: 00 00 00 00
LanParam 15,0: 00 00 00 00 00 00
LanParam 16,0: 70 75 62 6c 69 63 00 00 00 00 00 00 00 00 00 00 00 00
LanParam 17,0: 04
LanParam 18,1: 01 00 01 00 00
LanParam 18,2: 02 00 00 00 00
LanParam 18,3: 03 00 00 00 00
LanParam 18,4: 04 00 00 00 00
LanParam 19,1: 01 00 00 0a f3 2a d8 00 07 e9 06 15 30
LanParam 19,2: 02 00 00 00 00 00 00 00 00 00 00 00 00
LanParam 19,3: 03 00 00 00 00 00 00 00 00 00 00 00 00
LanParam 19,4: 04 00 00 00 00 00 00 00 00 00 00 00 00
LanParam 192,0: 00 00 00 00
LanParam 193,0: 00 00 00 00 00 00
LanParam 194,0: 00
ChannelAccess 1: 02 04
SOLParam 1,0: 01
SOLParam 2,0: 82
SOLParam 3,0: 04 32
SOLParam 4,0: 06 14
SOLParam 5,0: 0a
SOLParam 6,0: 00
SOLPayloadSupport 1: 00 15 00 00 00 00 00
SOLPayloadAccess 1,1: 02 00 00 00
SOLPayloadAccess 1,2: 02 00 00 00
SOLPayloadAccess 1,3: 00 00 00 00
UserAccess 1,1: 0f 02 01 14
UserName 1: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
# UserPassword 1: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
UserAccess 1,2: 0f 02 01 14
UserName 2: 75 73 72 32 00 00 00 00 00 00 00 00 00 00 00 00
# UserPassword 2: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
UserAccess 1,3: 0f 02 01 0f
UserName 3: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
# UserPassword 3: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
UserAccess 1,4: 0f 02 01 0f
UserName 4: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
# UserPassword 4: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SerialParam 0,0: 00
SerialParam 1,0: 15
SerialParam 2,0: 14 14 14 14 00
SerialParam 3,0: 87
SerialParam 4,0: 00
SerialParam 5,0: 00 00 ff ff ff
SerialParam 6,0: 03
SerialParam 7,0: 20 0a
SerialParam 8,0: 16 08
SerialParam 9,0: 3f 00
SerialParam 10,0: 01 41 54 45 31 51 30 56 31 58 34 26 44 32 26 43 31
SerialParam 11,0: 2b 2b 2b 00 00
SerialParam 12,0: 41 54 48 00 00 00 00 00
SerialParam 13,0: 41 54 44 00 00 00 00 00
SerialParam 14,0: 00
SerialParam 15,0: 70 75 62 6c 69 63 00 00 00 00 00 00 00 00 00 00 00 00
SerialParam 16,0: 08
SerialParam 17,1: 01 00 05 03 00
SerialParam 17,2: 02 00 05 03 00
SerialParam 17,3: 03 00 05 03 00
SerialParam 17,4: 04 00 05 03 00
SerialParam 18,0: 3c
SerialParam 19,1: 01 00 07
SerialParam 19,2: 02 00 07
SerialParam 19,3: 03 00 07
SerialParam 19,4: 04 00 07
SerialParam 29,0: 66 11
ChannelAccess 4: 2b 04
UserAccess 4,1: 0f 02 01 14
UserName 1: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
# UserPassword 1: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
UserAccess 4,2: 0f 02 01 14
UserName 2: 75 73 72 32 00 00 00 00 00 00 00 00 00 00 00 00
# UserPassword 2: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
UserAccess 4,3: 0f 02 01 0f
UserName 3: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
# UserPassword 3: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
UserAccess 4,4: 0f 02 01 0f
UserName 4: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
# UserPassword 4: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
# ipmiutil discover -a -b 10.243.42.255
ipmiutil ver 2.21
idiscover ver 1.3
Discovering IPMI Devices:
1: response from 10.243.42.141
2: response from 10.243.42.7
3: response from 10.243.42.14
4: response from 10.243.42.145
5: response from 10.243.42.172
6: response from 10.243.42.182
7: response from 10.243.42.185
8: response from 10.243.42.183
9: response from 10.243.42.184
10: response from 10.243.42.138
11: response from 10.243.42.181
12: response from 10.243.42.179
13: response from 10.243.42.139
14: response from 10.243.42.216
15: response from 10.243.42.210
16: response from 10.243.42.229
17: response from 10.243.42.150
18: response from 10.243.42.120
19: response from 10.243.42.246
20: response from 10.243.42.158
21: response from 10.243.42.168
22: response from 10.243.42.248
23: response from 10.243.42.242
24: response from 10.243.42.243
25: response from 10.243.42.223
26: response from 10.243.42.171
27: response from 10.243.42.174
28: response from 10.243.42.222
29: response from 10.243.42.226
30: response from 10.243.42.228
31: response from 10.243.42.110
32: response from 10.243.42.120
33: response from 10.243.42.128
34: response from 10.243.42.169
idiscover: 1 pings sent, 34 responses
# ipmiutil events 18 00 02 02 00 00 00 20 00 04 09 01 6f 44 0f ff
ipmiutil ver 2.40
ievents version 2.40
RecId Date/Time_______ Source_ Evt_Type SensNum Evt_detail - Trig [Evt_data]
0018 12/31/69 19:00:02 BMC 09 Power Unit #01 AC Lost 6f [44 0f ff]
ievents, completed successfully
# ipmiutil events -p -s sensor-TIGW1U.out B3 E8 00 0E 0C C7 1B A0 11 08 12 7F 10 90 FF FF 20 20 00 20 02 15 01 41 0F FF
ipmiutil ver 2.40
ievents version 2.40
0023 SDR Comp 02 2b 20 a 09 snum 02 Power Redundancy
0008 11/01/07 10:13:20 BMC 09 Power Unit #02 Redundancy Lost 0b [41 0f ff]
ievents, completed successfully
# ipmiutil fru
ipmiutil ver 2.21
fruconfig: version 2.21
-- BMC version 0.19, IPMI version 2.0
SDR[004c] FRU 20 00 0c 01 Baseboard FRU
SDR[004d] FRU 20 02 15 01 Power Dist FRU
Component FRU Size : 256
Product Manufacturer: DELTA
Product Name : AC-061 B
Product Part Number : D76441-003
Product Version : 00
Product Serial Num : DLD0719000969
Product Asset Tag :
Product FRU File ID :
SDR[004e] FRU 20 03 0a 01 Pwr Supply 1 FRU
Component FRU Size : 256
Product Manufacturer: DELTA
Product Name : DPS-450KBA
Product Part Number : D40117-007
Product Version : S6
Product Serial Num : DLD0721003047
Product Asset Tag :
Product FRU File ID :
SDR[004f] FRU 20 04 0a 02 Pwr Supply 2 FRU
Component FRU Size : 256
Product Manufacturer: DELTA
Product Name : DPS-450KBA
Product Part Number : D40117-003
Product Version : S2
Product Serial Num : DLC0630000244
Product Asset Tag :
Product FRU File ID :
SDR[0050] IPMB 20 00 07 01 Basbrd Mgmt Ctlr
Mainboard FRU Size : 256
Chassis Type : Rack-Mount Chassis
Chassis Part Number : TIGW1U
Chassis Serial Num :
Chassis OEM Field : TIGW1U
Board Mfg DateTime : Sun Jun 17 16:11:00 2007
Board Manufacturer : Intel
Board Product Name : S5000PHB
Board Serial Number : CFTW72400602
Board Part Number : D40552-601
Board FRU File ID : FRU Ver 0.05
Board OEM Field :
Product Manufacturer: Intel
Product Name : S5000PHB
Product Part Number : TMWA0201W
Product Version :
Product Serial Num : sernum4wd
Product Asset Tag : asset4wd
Product FRU File ID :
Product OEM Field :
System GUID : b1d84f76-1de2-11dc-b3e8-000e0cc71ba0
BIOS Version : S5000.86B.10.00.D414.081520081354
fruconfig, completed successfully
# ipmiutil getevt
ipmiutil ver 2.21
getevent ver 2.21
-- BMC version 0.19, IPMI version 2.0
event receiver sa = 20 lun = 00
bmc enables = 0f
Waiting 120 seconds for an event ...
got event, sensor_type = 01
event data: 3c 22 02 7b e6 bf 48 20 00 04 01 30 01 50 2e 33
223c 09/04/08 09:45:31 BMC 01 Temperature #30 Lo Noncrit thresh act=2e thr=33
Waiting 120 seconds for an event ...
got event, sensor_type = 01
event data: 64 22 02 7d e6 bf 48 20 00 04 01 30 81 50 2e 07
2264 09/04/08 09:45:33 BMC 01 Temperature #30 LoN thresh OK now act=2e thr=07
Waiting 120 seconds for an event ...
get_event timeout
getevent, completed successfully
# ipmiutil health
ipmiutil ver 2.21
bmchealth ver 2.21
BMC version 0.19, IPMI version 2.0
BMC manufacturer = 000157 (Intel), product = 0811 (TIGW1U)
BIOS Version = S5000.86B.10.00.D414.081520081354
Chassis Status = 01 (on, restore_policy=stay_off)
Power State = 00 (S0: working)
Selftest status = 0055 (OK)
Channel 15 Auth Types:
Status = 00, OEM ID 000000 OEM Aux 00
bmchealth, completed successfully
# ipmiutil lan
ipmiutil ver 2.21
pefconfig ver 2.21
-- BMC version 0.19, IPMI version 2.0
pefconfig, GetPefEntry ...
PEFilter(01): 01 Temperature Sensor event - enabled for alert
PEFilter(02): 02 Voltage Sensor event - enabled for alert
PEFilter(03): 04 Fan Failure event - enabled for alert
PEFilter(04): 05 Chassis Intrusion event - enabled for alert
PEFilter(05): 08 Power Supply Fault event - enabled for alert
PEFilter(06): 0c Memory ECC Error event - enabled for alert
PEFilter(07): 0f FRB Failure event - enabled for alert
PEFilter(08): 07 BIOS POST Error event - enabled for alert
PEFilter(09): 13 Fatal NMI event - enabled for alert
PEFilter(10): 23 Watchdog Timer Reset event - enabled for alert
PEFilter(11): 12 System Restart event - enabled for alert
PEFilter(12): 20 OS Critical Stop event - enabled for alert
PEFilter(13): 09 Power Redundancy Lost event - enabled for alert
PEFilter(14): 09 Power Unit OK event - enabled for alert
PEFilter(15): 01 Temperature OK event - enabled for alert
PEF Control: 01 : PEFenable
PEF Actions: 2f : Alert PwrDn Reset PwrCyc DiagInt
PEF Startup Delay: 3c : 60 sec
PEF Alert Startup Delay: 3c: 60 sec
PEF Alert Policy[1]: 01 18 11 00 : Chan[1] Dest[1] Enabled
PEF Alert Policy[2]: 02 00 00 00 : Disabled
PEF Alert Policy[3]: 03 00 00 00 : Disabled
PEF Alert Policy[4]: 04 00 00 00 : Disabled
pefconfig, GetLanEntry for channel 1 ...
Lan Param(0) Set in progress: 00
Lan Param(1) Auth type support: 15 : None MD5 Pswd
Lan Param(2) Auth type enables: 14 14 14 14 00
Lan Param(3) IP address: 10 243 42 235
Lan Param(4) IP addr src: 01 : Static
Lan Param(5) MAC addr: 00 0e 0c c7 1b a2
Lan Param(6) Subnet mask: 255 255 255 0
Lan Param(7) IPv4 header: 40 40 10
Lan Param(10) BMC grat ARP: 01 : Grat-ARP enabled
Lan Param(11) grat ARP interval: 04 : 2 sec
Lan Param(12) Def gateway IP: 10 243 42 251
Lan Param(13) Def gateway MAC: 00 d0 06 21 eb fc
Lan Param(14) Sec gateway IP: 0 0 0 0
Lan Param(15) Sec gateway MAC: 00 00 00 00 00 00
Lan Param(16) Community string: public
Lan Param(17) Num dest: 04
Lan Param(18) Dest type: 01 00 01 00 00
Lan Param(18) Dest type: 02 00 00 00 00
Lan Param(18) Dest type: 03 00 00 00 00
Lan Param(18) Dest type: 04 00 00 00 00
Lan Param(19) Dest address: 01 00 00 [10 243 42 216] 00 07 e9 06 15 30
Lan Param(19) Dest address: 02 00 00 [0 0 0 0] 00 00 00 00 00 00
Lan Param(19) Dest address: 03 00 00 [0 0 0 0] 00 00 00 00 00 00
Lan Param(19) Dest address: 04 00 00 [0 0 0 0] 00 00 00 00 00 00
Lan Param(192) DHCP Server IP: 0 0 0 0
Lan Param(193) DHCP MAC Address: 00 00 00 00 00 00
Lan Param(194) DHCP Enable: 00
Channel Access Mode(1=lan): 02 04 : Access = Always Avail, PEF Alerts Enabled
pefconfig, GetSOL for channel 1 ...
SOL Enable: 01 : enabled
SOL Auth: 82 : User
SOL Accum Interval: 04 32 : 20 msec
SOL Retry Interval: 06 14 : 200 msec
SOL nvol Baud Rate: 0a : 115.2k
SOL vol Baud Rate: 00 : nobaud
SOL Payload Support(1): 03 00 15 00 00 00 00 00
SOL Payload Access(1,1): 02 00 00 00 : enabled
SOL Payload Access(1,2): 02 00 00 00 : enabled
SOL Payload Access(1,3): 00 00 00 00 : disabled
SOL Payload Access(1,4): 00 00 00 00 : disabled
Get User Access(1): 0f 02 01 14 : IPMI, Admin ()
Get User Access(2): 0f 02 01 14 : IPMI, Admin (usr2)
Get User Access(3): 0f 02 01 0f : No access ()
Get User Access(4): 0f 02 01 0f : No access ()
pefconfig, completed successfully
# ipmiutil reset -n
ipmiutil ver 2.21
hwreset ver 2.21
-- BMC version 0.19, IPMI version 2.0
Power State = 00 (S0: working)
hwreset: sending NMI ...
chassis_reset ok
hwreset: IPMI_Reset ok
hwreset, completed successfully
# ipmiutil sel
ipmiutil ver 2.21
showsel: version 2.21
-- BMC version 0.19, IPMI version 2.0
SEL Ver 51 Support f, Size = 3987 records, Free space = 3553 records
RecId Date/Time_______ Source_ Evt_Type SensNum Evt_detail - Trig [Evt_data]
0004 07/16/08 15:17:58 BMC 10 SEL Disabled #09 Log Cleared 6f [42 0f ff]
0018 07/16/08 15:23:08 BIOS 12 System Event #83 Boot: ClockSync_1 6f [05 00 ff]
002c 07/16/08 10:23:08 BIOS 12 System Event #83 Boot: ClockSync_2 6f [05 80 ff]
0040 07/16/08 10:24:37 0033 12 System Event #01 OEM System Booted 6f [01 ff 00]
0054 07/16/08 10:24:49 BMC 22 ACPI Power State #82 S0/G0 Working 6f [40 0f ff]
0068 07/16/08 11:12:55 BMC 08 Power Supply #70 Removed ef [40 0f ff]
007c 07/16/08 11:12:55 BMC 09 Power Unit #02 Redundancy Lost 0b [41 0f ff]
0090 07/16/08 11:12:55 BMC 09 Power Unit #02 Not Redundant 0b [43 0f ff]
00a4 07/16/08 11:13:23 BMC 08 Power Supply #70 Inserted 6f [40 0f ff]
00b8 07/16/08 11:13:23 BMC 09 Power Unit #02 Redundancy OK 0b [40 0f ff]
00cc 07/16/08 11:31:30 BMC 08 Power Supply #70 Removed ef [40 0f ff]
00e0 07/16/08 11:31:31 BMC 09 Power Unit #02 Redundancy Lost 0b [41 0f ff]
00f4 07/16/08 11:31:31 BMC 09 Power Unit #02 Not Redundant 0b [43 0f ff]
0108 07/16/08 11:31:40 BMC 08 Power Supply #70 Inserted 6f [40 0f ff]
011c 07/16/08 11:31:41 BMC 09 Power Unit #02 Redundancy OK 0b [40 0f ff]
0130 07/16/08 11:46:34 BMC 01 Temperature #30 Lo Noncrit thresh act=2f thr=34
0144 07/16/08 11:46:34 BMC 01 Temperature #30 Lo Crit thresh act=2f thr=33
0158 07/16/08 11:46:36 BMC 01 Temperature #30 LoN thresh OK now act=2f thr=07
016c 07/16/08 11:46:36 BMC 01 Temperature #30 LoC thresh OK now act=2f thr=06
0180 07/16/08 12:00:59 BMC 08 Power Supply #70 Removed ef [40 0f ff]
0194 07/16/08 12:01:00 BMC 09 Power Unit #02 Redundancy Lost 0b [41 0f ff]
01a8 07/16/08 12:01:00 BMC 09 Power Unit #02 Not Redundant 0b [43 0f ff]
01bc 07/16/08 12:01:32 BMC 08 Power Supply #70 Inserted 6f [40 0f ff]
[...]
1a08 08/12/08 01:57:20 SMI 20 OS Critical Stop #64 panic(dop) 6f [a1 6f 70]
1a1c 08/12/08 01:58:08 BMC 2a Session Audit #0a Deactivated User 1 6f [a1 01 11]
1a30 08/12/08 01:58:18 BMC 2a Session Audit #0a Activated User 1 6f [a0 01 01]
[...]
219c 08/27/08 06:29:24 BIOS 12 System Event #83 Boot: ClockSync_1 6f [05 00 ff]
21b0 08/27/08 06:29:25 BIOS 12 System Event #83 Boot: ClockSync_2 6f [05 80 ff]
21c4 08/27/08 06:30:18 0033 12 System Event #01 OEM System Booted 6f [01 ff 00]
21d8 08/27/08 06:30:29 BMC 22 ACPI Power State #82 S0/G0 Working 6f [40 0f ff]
showsel, completed successfully
# ipmiutil sensor
ipmiutil ver 2.21
sensor: version 2.21
-- BMC version 0.20, IPMI version 2.0
_ID_ SDR_Type_xx ET Own Typ S_Num Sens_Description Hex & Interp Reading
0001 SDR Full 01 01 20 a 02 snum 10 BB +1.2V Vtt = be OK 1.20 Volts
0002 SDR Full 01 01 20 a 02 snum 12 BB +1.5V AUX = bd OK 1.47 Volts
0003 SDR Full 01 01 20 a 02 snum 13 BB +1.5V = 75 OK 1.52 Volts
0004 SDR Full 01 01 20 a 02 snum 14 BB +1.8V = af OK 1.78 Volts
0005 SDR Full 01 01 20 a 02 snum 15 BB +3.3V = c1 OK 3.32 Volts
0006 SDR Full 01 01 20 a 02 snum 16 BB +3.3V STB = bf OK 3.29 Volts
0007 SDR Full 01 01 20 a 02 snum 17 BB +1.5V ESB = be OK 1.48 Volts
0008 SDR Full 01 01 20 a 02 snum 18 BB +5V = c3 OK 5.07 Volts
0009 SDR Full 01 01 20 a 02 snum 1a BB +12V AUX = c1 OK 11.97 Volts
000a SDR Full 01 01 20 a 02 snum 1b BB +0.9V = ba OK 0.89 Volts
000b SDR Full 01 01 20 a 01 snum 30 Baseboard Temp = 2d OK 45.00 degrees C
000c SDR Full 01 01 20 a 01 snum 32 Front Panel Temp = 1a OK 26.00 degrees C
000d SDR Full 01 01 20 a 01 snum 48 Mem Therm Margin = 00 Init 0.00 degrees C
000e SDR Full 01 01 20 m 04 snum 50 Fan 1A = 6f OK 7659.00 RPM
000f SDR Full 01 01 20 m 04 snum 51 Fan 1B = 6b OK 5457.00 RPM
0010 SDR Full 01 01 20 m 04 snum 52 Fan 2A = 69 OK 7245.00 RPM
0011 SDR Full 01 01 20 m 04 snum 53 Fan 2B = 6b OK 5457.00 RPM
0012 SDR Full 01 01 20 m 04 snum 54 Fan 3A = 6c OK 7452.00 RPM
0013 SDR Full 01 01 20 m 04 snum 55 Fan 3B = 6b OK 5457.00 RPM
0014 SDR Full 01 01 20 m 04 snum 56 Fan 4A = 6f OK 7659.00 RPM
0015 SDR Full 01 01 20 m 04 snum 57 Fan 4B = 69 OK 5355.00 RPM
0016 SDR Full 01 01 20 m 04 snum 58 Fan 5 = 63 OK 6534.00 RPM
0017 SDR Full 01 01 20 a 03 snum 78 PS1 AC Current = 05 OK 0.31 Amps
0018 SDR Full 01 01 20 a 03 snum 79 PS2 AC Current = 16 OK 1.39 Amps
0019 SDR Full 01 01 20 a 03 snum 7a PS1 +12V Current = 01 OK 0.50 Amps
001a SDR Full 01 01 20 a 03 snum 7b PS2 +12V Current = 12 OK 9.00 Amps
001b SDR Full 01 01 20 a 0b snum 7c PS1 +12V Power = 01 OK 4.00 Watts
001c SDR Full 01 01 20 a 0b snum 7d PS2 +12V Power = 1b OK 108.00 Watts
001d SDR Full 01 01 20 a 01 snum 99 P1 Therm Margin = c7 OK -57.00 degrees C
001e SDR Full 01 01 20 m 01 snum c0 P1 Therm Ctrl % = 00 OK 0.00 unspecified
001f SDR Full 01 01 20 a 02 snum d0 Proc 1 Vccp = b0 OK 1.09 Volts
0020 SDR Comp 02 6f 20 a 09 snum 01 Power Unit = 00 c0 00 00 Enabled
0021 SDR Comp 02 0b 20 a 09 snum 02 Power Redundancy = 00 c0 01 00 Redundant
0022 SDR Comp 02 6f 20 a 23 snum 03 BMC Watchdog = 00 c0 00 00 OK
0023 SDR Comp 02 6f 20 a 06 snum 04 Scrty Violation = 00 c0 00 00 OK
0024 SDR Comp 02 6f 20 a 13 snum 07 FP Interrupt = 00 c0 00 00 OK
0025 SDR Comp 02 6f 20 a 10 snum 09 Event Log Clear = 00 c0 00 00 OK
0026 SDR Comp 02 6f 20 a 2a snum 0a Session Audit = 00 c0 00 00 Activated
0027 SDR Comp 02 6f 20 a 12 snum 0b System Event = 00 c0 00 00 OK
0028 SDR Comp 02 6f 20 a 29 snum 1e BB Vbat = 00 c0 00 00 OK
0029 SDR Comp 02 6f 20 a 08 snum 70 PS1 Status = 00 c0 01 00 Present
002a SDR Comp 02 6f 20 a 08 snum 71 PS2 Status = 00 c0 01 00 Present
002b SDR Comp 02 6f 20 a 22 snum 82 ACPI State = 00 c0 01 00 Working
002c SDR Comp 02 6f 20 a 14 snum 84 Button = 00 c0 00 00 OK
002d SDR Comp 02 03 20 a f3 snum 85 SMI Timeout = 00 c0 01 00 Enabled
002e SDR Comp 02 03 20 a c0 snum 87 NMI State = 00 c0 01 00 Enabled
002f SDR Comp 02 03 20 a c0 snum 88 SMI State = 00 80 01 00 Enabled
0030 SDR Comp 02 6f 20 m 07 snum 90 Processor 1 Stat = 00 c0 80 00 ProcPresent
0031 SDR Comp 02 6f 20 a 13 snum a0 PCIe Link0 = 00 c0 00 00 OK
0032 SDR Comp 02 6f 20 a 13 snum a1 PCIe Link1 = 00 c0 00 00 OK
0033 SDR Comp 02 6f 20 a 13 snum a2 PCIe Link2 = 00 c0 00 00 OK
0034 SDR Comp 02 6f 20 a 13 snum a3 PCIe Link3 = 00 c0 00 00 OK
0035 SDR Comp 02 6f 20 a 13 snum a4 PCIe Link4 = 00 c0 00 00 OK
0036 SDR Comp 02 6f 20 a 13 snum a5 PCIe Link5 = 00 c0 00 00 OK
0037 SDR Comp 02 6f 20 a 13 snum a6 PCIe Link6 = 00 c0 00 00 OK
0038 SDR Comp 02 6f 20 a 13 snum a7 PCIe Link7 = 00 c0 00 00 OK
0039 SDR Comp 02 6f 20 a 13 snum a8 PCIe Link8 = 00 c0 00 00 OK
003a SDR Comp 02 6f 20 a 13 snum a9 PCIe Link9 = 00 c0 00 00 OK
003b SDR Comp 02 6f 20 a 13 snum aa PCIe Link10 = 00 c0 00 00 OK
003c SDR Comp 02 6f 20 a 13 snum ab PCIe Link11 = 00 c0 00 00 OK
003d SDR Comp 02 6f 20 a 13 snum ac PCIe Link12 = 00 c0 00 00 OK
003e SDR Comp 02 6f 20 a 13 snum ad PCIe Link13 = 00 c0 00 00 OK
003f SDR Comp 02 05 20 m 01 snum c8 CPU1 VRD Temp = 00 c0 00 00 OK*
0040 SDR Comp 02 05 20 a 02 snum d2 CPU1 Vcc OOR = 00 c0 00 00 OK
0041 SDR Comp 02 03 20 a 07 snum d8 CPU Popul Error = 00 c0 00 00 OK
0042 SDR Comp 02 6f 20 a 21 snum e0 DIMM 1A = 00 c0 04 00 Present
0043 SDR Comp 02 6f 20 a 21 snum e1 DIMM 2A = 00 e0 40 00 NotAvailable
0044 SDR Comp 02 6f 20 a 21 snum e2 DIMM 3A = 00 e0 40 00 NotAvailable
0045 SDR Comp 02 6f 20 a 21 snum e3 DIMM 1B = 00 c0 04 00 Present
0046 SDR Comp 02 6f 20 a 21 snum e4 DIMM 2B = 00 e0 40 00 NotAvailable
0047 SDR Comp 02 6f 20 a 21 snum e5 DIMM 3B = 00 e0 40 00 NotAvailable
0048 SDR Comp 02 6f 20 a 0c snum ec Mem A Error = 00 c0 00 00 OK
0049 SDR Comp 02 6f 20 a 0c snum ed Mem B Error = 00 c0 00 00 OK
004a SDR Comp 02 6f 20 a 25 snum f0 DIMM Spare Enb = 00 e0 40 00 NotAvailable
004b SDR Comp 02 0b 20 a 0c snum f1 DIMM Spare Redu = 00 e0 40 00 NotAvailable
004c SDR FRU 11 18 dev: 20 00 80 00 0c 01 Baseboard FRU
004d SDR FRU 11 19 dev: 20 02 80 00 15 01 Power Dist FRU
004e SDR FRU 11 1b dev: 20 03 80 00 0a 01 Pwr Supply 1 FRU
004f SDR FRU 11 1b dev: 20 04 80 00 0a 02 Pwr Supply 2 FRU
0050 SDR IPMB 12 1b dev: 20 00 bf 07 01 Basbrd Mgmt Ctlr
0051 SDR OEM c0 09 Intel: 02 02 00 01 70 71
0052 SDR OEM c0 05 Intel: 06 01
0053 SDR OEM c0 19 Intel: 0b 01 01 32 14 f0 0a a4 01 96 00 61 00 08 0a 64 00 05 00 00 00 00
0054 SDR OEM c0 19 Intel: 0b 02 01 32 14 f0 0a a4 01 ff ff ff ff 10 14 ff ff 06 00 00 00 00
0055 SDR OEM c0 19 Intel: 0b 01 02 32 14 f0 0a a4 01 96 00 61 00 08 0a 64 00 05 00 00 00 00
0056 SDR OEM c0 19 Intel: 0b 02 02 32 14 f0 0a a4 01 ff ff ff ff 10 14 ff ff 06 00 00 00 00
0057 SDR OEM c0 2c Intel: 0c 01 30 64 64 01 02 03 30 20 32 64 01 90 0d 00 2b 20 30 21 35 22 3a 23 3f 24 43 25 47 26 4c 27 51 28 56 29 5b 2a 60 2b 64
0058 SDR OEM c0 2c Intel: 0c 02 30 64 64 01 02 03 30 20 32 64 01 90 0d 00 2b 20 30 21 35 22 3a 23 3f 24 43 25 47 26 4c 27 51 28 56 29 5b 2a 60 2b 64
0059 SDR OEM c0 2c Intel: 0c 03 30 64 64 01 02 03 30 20 32 64 01 90 0d 00 2b 20 30 21 35 22 3a 23 3f 24 43 25 47 26 4c 27 51 28 56 29 5b 2a 60 2b 64
005a SDR OEM c0 15 Intel: 0c 01 30 64 64 01 02 03 00 20 99 64 02 90 01 06 00 11
005b SDR OEM c0 15 Intel: 0c 01 30 64 64 01 02 03 00 20 48 00 02 b8 01 02 00 00
005c SDR OEM c0 15 Intel: 0c 02 30 64 64 01 02 03 00 20 99 64 02 90 01 06 00 11
005d SDR OEM c0 15 Intel: 0c 03 30 64 64 01 02 03 00 20 30 64 02 90 01 02 3c 00
005e SDR OEM c0 0e Intel: 08 00 00 45 88 45 88 45 88 45 88
005f SDR OEM c0 16 Intel: 09 00 00 90 33 90 33 90 33 90 33 90 33 90 33 68 42 68 42
0060 SDR OEM c0 08 Intel: BMC_TAM0 60 01 03 01 20 nrec=4 cfg=01
0061 SDR OEM c0 31 Intel: BMC_TAM1 60 01 13 00 20 41 01 01 01 23 71 93 41 02 01 02 24 72 94 41 03 01 02 24 72 94 21 04 01 01 23 11 02 05 14 31 29 6f 01 13 23 21 09 0b 14 34
0062 SDR OEM c0 31 Intel: BMC_TAM2 60 01 23 00 20 71 07 6f 03 13 23 33 43 55 83 11 08 6f 14 21 09 6f 54 64 20 7c 01 72 94 20 7d 01 72 94 11 21 6f 03 53 23 6f 05 15 25 35 85
0063 SDR OEM c0 17 Intel: BMC_TAM3 60 01 33 00 c0 22 02 00 03 51 22 03 00 03 51 22 04 00 03 51
0064 SDR OEM c0 0e Intel: SDR File 18
0065 SDR OEM c0 11 Intel: SDR Package 18
SDR IPMI sensor: Power On Hours = 6923 hours
sensor, completed successfully
# ipmiutil serial
ipmiutil ver 2.21
tmconfig ver 2.21
-- BMC version 0.19, IPMI version 2.0
Code 0 SEL Ver 81 Support 15
tmconfig: GetSerEntry for channel 4 ...
Serial Param(0) Set in progress: 00
Serial Param(1) Auth type support: 15 : None MD5 Pswd
Serial Param(2) Auth type enables: 14 14 14 14 00
Serial Param(3) Connection Mode: 87
Serial Param(4) Sess Inactiv Timeout: 00 : infinite
Serial Param(5) Channel Callback: 00 00 ff ff ff
Serial Param(6) Session Termination: 03
Serial Param(7) IPMI Msg Comm: 20 0a : no_flow, DTR, 115.2k
Serial Param(8) Mux Switch: 16 08
Serial Param(9) Modem Ring Time: 3f 00
Serial Param(10) Modem Init String: 01 ATE1Q0V1X4&D2&C1
Serial Param(11) Modem Escape Seq: +++
Serial Param(12) Modem Hangup Seq: ATH
Serial Param(13) Modem Dial Command: ATD
Serial Param(14) Page Blackout Interval: 00
Serial Param(15) Community String: public
Serial Param(16) Num of Alert Dest: 08
Serial Param(17) Destination Info: 01 00 05 03 00
Serial Param(17) Destination Info: 02 00 05 03 00
Serial Param(17) Destination Info: 03 00 05 03 00
Serial Param(17) Destination Info: 04 00 05 03 00
Serial Param(17) Destination Info: 05 00 05 03 00
Serial Param(17) Destination Info: 06 00 05 03 00
Serial Param(17) Destination Info: 07 00 05 03 00
Serial Param(17) Destination Info: 08 00 05 03 00
Serial Param(18) Call Retry Interval: 3c
Serial Param(19) Destination Comm Settings: 01 00 07 : no_flow, 8N1, 19.2k
Serial Param(19) Destination Comm Settings: 02 00 07 : no_flow, 8N1, 19.2k
Serial Param(19) Destination Comm Settings: 03 00 07 : no_flow, 8N1, 19.2k
Serial Param(19) Destination Comm Settings: 04 00 07 : no_flow, 8N1, 19.2k
Serial Param(19) Destination Comm Settings: 05 00 07 : no_flow, 8N1, 19.2k
Serial Param(19) Destination Comm Settings: 06 00 07 : no_flow, 8N1, 19.2k
Serial Param(19) Destination Comm Settings: 07 00 07 : no_flow, 8N1, 19.2k
Serial Param(19) Destination Comm Settings: 08 00 07 : no_flow, 8N1, 19.2k
Serial Param(20) Number Dial Strings: 06
Serial Param(21) Dest Dial String: 01 01
Serial Param(21) Dest Dial String: 02 01
Serial Param(21) Dest Dial String: 03 01
Serial Param(21) Dest Dial String: 04 01
Serial Param(21) Dest Dial String: 05 01
Serial Param(21) Dest Dial String: 06 01
Serial Param(22) Number Dest IP Addrs: 04
Serial Param(23) Dest IP Address: 01 0 0 0 0
Serial Param(23) Dest IP Address: 02 0 0 0 0
Serial Param(23) Dest IP Address: 03 0 0 0 0
Serial Param(23) Dest IP Address: 04 0 0 0 0
Serial Param(29) Terminal Mode Config: 66 11
Channel Access Mode(4=Ser): 2b 04 : Access = Shared, PEF Alerts Disabled
Get User Access (1): 0f 02 01 14 : IPMI, Admin ()
Get User Access (2): 0f 02 01 14 : IPMI, Admin (usr2)
Get User Access (3): 0f 02 01 0f : No access ()
Get User Access (4): 0f 02 01 0f : No access ()
Get Serial MUX Status: 04
Get Boot Options(3): 01 03 00
tmconfig, completed successfully
# ipmiutil sol -a -N 10.243.42.136
ipmiutil ver 2.21
isolconsole ver 2.21
Opening connection to node 10.243.42.136 ...
Connected to node 10.243.42.136 10.243.42.136
-- BMC version 0.17, IPMI version 2.0
Opening connection to node 10.243.42.136 ...
[SOL session is running, use '~' to end session.]
isolconsole exit via user input
isolconsole, completed successfully
# ipmiutil wdt
ipmiutil ver 2.21
wdt ver 2.21
-- BMC version 0.19, IPMI version 2.0
wdt data: 01 01 00 00 00 00 00 00
Watchdog timer is stopped for use with BIOS FRB2. Logging
pretimeout is 0 seconds, pre-action is None
timeout is 0 seconds, counter is 0 seconds
action is Hard Reset
wdt, completed successfully
# ipmi_port
ipmi_port ver 1.1
open_rmcp_port(623) succeeded, sleeping
--------------------------
7.0 PROBLEMS
--------------------------
Note that each utility function has an option for extra debug output (-x),
which can be used to find out the specific function which returned an
error.
For best-effort support, email the ipmiutil-developer mailing list:
http://lists.sourceforge.net/lists/listinfo/ipmiutil-developers
or enter a bug report at:
http://sourceforge.net/tracker/?group_id=116222&func=browse
7.1 ERROR RETURN CODES
Return code = 0 means success, negative numbers indicate failure, and a
positive return code represents an IPMI completion code.
RetCode Description
------ -----------------------------------------
0 "completed successfully"
-1 "error -1", a generic error, usually returned by an OS routine
-2 "send to BMC failed" over IPMI LAN
-3 "receive from BMC failed" over IPMI LAN
-4 "cannot connect to BMC" over IPMI LAN
-5 "abort signal caught", the user pressed Ctl-C
-6 "timeout occurred", the timeout for a response expired
-7 "length greater than max", length supplied was too big
-8 "invalid lan parameter", invalid parameter for IPMI LAN function
-9 "request not supported", a requested function is not supported
-10 "receive too short", did not receive the minimum number of bytes
-11 "error resolving hostname" neither DNS or hosts could resolve to an IP
-12 "error during ping" could not perform the RMCP ping function
-13 "BMC only supports lan v1". LAN 2.0 (lanplus) was attempted, but this
BMC firmware only supports IPMI LAN 1.x
-14 "BMC only supports lan v2". LAN 1.x was attempted, but this BMC
supports LAN 2.0 but not LAN 1.x, which violates the IPMI 2.0 spec.
-15 "other error", an unknown error occurred
-16 "cannot open IPMI driver". No IPMI driver could be opened. Since
the driverless mode is also attempted, this usually means that the
user does not have root privilege.
-17 "invalid parameter" a parameter was out of bounds
-18 "access not allowed" user does not have access to this file or function
-19 "session dropped by BMC" the BMC firmware aborted the IPMI session
-20 "cannot open file" cannot open the specified file
-21 "item not found" requested item was not found
-22 "usage or help requested", the user requested usage/help
-23 "bad format", the data format is invalid, cannot proceed
-504 "error getting msg from BMC" during driverless I/Os, a command did
not get a response.
7.2 IPMI COMPLETION CODES
IPMI Completion Codes are defined in IPMI 1.5, Table 5-2, and are also
included below in both hex and decimal format. Note that the meaning of
completion codes 0x80-0x9f may vary depending on the command.
Code Dec Description
---- --- -----------------------------------------
0x00, 0, "Command completed successfully",
0x80, 128, "Invalid Session Handle or Empty Buffer",
0x81, 129, "Lost Arbitration",
0x82, 130, "Bus Error",
0x83, 131, "NAK on Write - busy",
0x84, 132, "Truncated Read",
0xC0, 192, "Node Busy",
0xC1, 193, "Invalid Command",
0xC2, 194, "Command invalid for given LUN",
0xC3, 195, "Timeout while processing command",
0xC4, 196, "Out of space",
0xC5, 197, "Invalid Reservation ID, or cancelled",
0xC6, 198, "Request data truncated",
0xC7, 199, "Request data length invalid",
0xC8, 200, "Request data field length limit exceeded",
0xC9, 201, "Parameter out of range",
0xCA, 202, "Cannot return requested number of data bytes",
0xCB, 203, "Requested sensor, data, or record not present",
0xCC, 204, "Invalid data field in request",
0xCD, 205, "Command illegal for this sensor/record type",
0xCE, 206, "Command response could not be provided",
0xCF, 207, "Cannot execute duplicated request",
0xD0, 208, "SDR Repository in update mode, no response",
0xD1, 209, "Device in firmware update mode, no response",
0xD2, 210, "BMC initialization in progress, no response",
0xD3, 211, "Destination unavailable",
0xD4, 212, "Cannot execute command. Insufficient privilege level",
0xD5, 213, "Cannot execute command. Request parameters not supported",
0xFF, 255, "Unspecified error"
-------------------------------
8.0 BUILDING IPMI UTILITIES
-------------------------------
The ipmiutil source package provides IPMI-based utilities and kernel
patches for managing various servers in Linux or Windows.
The same source files can be built in both Linux and Windows as shown
below.
To get the ipmiutil source:
Download the latest released ipmiutil-*.tar.gz from
http://sourceforge.net/projects/ipmiutil/files/
Or download a tar.gz of the current subversion trunk with the latest source
http://ipmiutil.svn.sourceforge.net/viewvc/ipmiutil/trunk/?view=tar
Or, if you have subversion installed, you can check out the latest source
by doing:
# svn co https://ipmiutil.svn.sourceforge.net/svnroot/ipmiutil ipmiutil
See also section 4.9 for information about building custom applications
using ipmiutil library APIs. The ipmi_sample.c shows a sample application
using the ipmiutil library.
8.1 Build instructions for Linux
Prerequisite packages to build the binaries (make):
autoconf automake libopenssl-devel gcc gcc-c++ libtool
Prerequisite packages to make the rpm (make rpm):
rpm rpm-build
To build with some GPL code:
If you are building ipmiutil for open-source, then the MD2 hash
for IPMI LAN and the valinux driver interface (/dev/ipmikcs) can
be supported. If so, you should specify the following during
configure:
"./configure --enable-gpl"
The default is to build with only BSD-licensed code and not to
include the MD2 and valinux features. The md2.h and ipmi_ioctl.h
files with GPL code can be removed if this option is not enabled.
To build a standalone binary without IPMI LAN 2.0 (lanplus plugin),
which may be desirable for use on bootable media (USB/CDROM), to
decrease the size or to avoid using libcrypto, you can specify the
following during configure:
"./configure --enable-standalone"
builds it without lanplus libs and without GPL code.
Only the SOL console function requires lanplus, all other functions can
use the lan interface, since the IPMI 2.0 firmware is required to support
both lan and lanplus. However, lanplus does have more secure encryption,
as provided by libcrypto.
To add LanDesk IPMI support:
Support for the LanDesk IPMI driver requires a library supplied by
LanDesk (libipmiapi.a). After obtaining this library, place it in
lib/libipmiapi.a. Then you can link ipmiutil to support it by
specifying the following during configure:
"./configure --enable-landesk=yes"
Steps to build for Linux:
# ./beforeconf.sh
Which automates these functions:
* copying libtool files
* aclocal (may be needed if automake versions are different)
* autoconf (may be needed if automake versions are different)
* automake
# ./configure
--enable-landesk adds landesk library support [default=no]
--disable-lanplus disable lanplus library support
--enable-standalone build standalone, with no GPL or LanPlus libs.
--enable-gpl build with some GPL code [default=no]
# make
To add the ifruset utility, which allows setting any FRU Product fields:
# cd util; make ifruset
# ifruset -?
To build and install an rpm package, use one of the following:
# make install
# make rpm
The make rpm produces a binary rpm, and a source rpm, which can be
installed with "rpm -i *.rpm".
To build and install a Debian package, do this:
# mv debpkg debian
# dpkg-buildpackage
then install it with "dpkg -i *.deb".
8.2 Build instructions for Windows
The ipmiutil Windows binaries for each release are pre-built and posted
at http://ipmiutil.sourceforge.net, but here is how to build the ipmiutil
EXEs for Windows from source.
Note that the WIN32 compile flag is used.
The ipmiutil buildwin.cmd shows how to compile and link the lib and exe
files, although many people prefer instead to do builds with the
Microsoft VisualStudio project GUI.
See also ipmiutil UserGuide section 5.2 for more details.
1) Install Visual Studio (e.g. VS 6.0 or VC98)
2) Download contrib files from
http://ipmiutil.sf.net/FILES/ipmiutil-contrib.zip
and see section 5.2 for getopt.c and openssl.
3) Copy initial contrib files into ipmiutil
See section 5.2.3 for details
4) Build the openssl libraries according to its INSTALL.W32
5) Copy the resulting openssl LIB and DLL binaries to ipmiutil
6) Set the Visual C variables
Example: "C:\Program Files\Microsoft Visual Studio 8\VC\bin\vcvars32.bat"
7) Run buildwin.cmd
buildwin.cmd will build all of the Windows EXE and DLL files.
8.3 Build instructions for Solaris
# iver=2.7.9
# uname -a
SunOS unknown 5.10 Generic_127128-11 i86pc i386 i86pc
# gunzip ipmiutil-${iver}.tar.gz
# tar xvf ipmiutil-${iver}.tar
# cd ipmiutil-${iver}
# PATH=/usr/sbin:/usr/bin:/usr/ucb:/usr/openwin:/usr/ccs/bin:/usr/sfw/bin
# ./configure
# make
# make tarsol
This produces /tmp/ipmiutil-${iver}-solaris.tar with the binaries.
# gzip /tmp/ipmiutil-${iver}-solaris.tar
Solaris Release Notes:
- Built with support for bmc, lan, and lanplus interfaces.
Supports the Solaris 10 /dev/bmc driver via putmsg method.
- Requests to slave addresses other than BMC are not supported by
the Solaris bmc driver (e.g. to HSC at 0xc0), and are sent to
the BMC sa instead.
- Memory mapping logic returns an error (e.g. BIOS version).
- idiscover -a broadcast ioctl works now in ipmiutil-2.3.1
To Install on Solaris:
gunzip /tmp/ipmiutil-${iver}-solaris.tar.gz
tar xvf /tmp/ipmiutil-${iver}-solaris.tar
./install.sh
8.4 Build instructions for FreeBSD
# iver=2.7.9
# gunzip ipmiutil-${iver}.tar.gz
# tar xvf ipmiutil-${iver}.tar
# cd ipmiutil-${iver}
# ./configure
# make
# make tarbsd
This produces /tmp/ipmiutil-${iver}-bsd.tar with the binaries.
# gzip /tmp/ipmiutil-${iver}-bsd.tar
FreeBSD Release Notes:
- ipmiutil-2.3.5 supports FreeBSD with direct driverless KCS
- ipmiutil-2.5.2 adds support for FreeBSD 7.x ipmi driver port
To Install on FreeBSD:
gunzip /tmp/ipmiutil-${iver}-bsd.tar.gz
tar xvf /tmp/ipmiutil-${iver}-bsd.tar
./install.sh
8.5 Build instructions for ARM (Android)
# tar -xzvf ipmiutil-${iver}.tar.gz
# cd ipmiutil-${iver}
# ./configure --enable-standalone --host=arm
# make
-----------------------------
10.0 IPMIUTIL LIBRARY APIS
-----------------------------
Below are some common routines available in the ipmiutil library.
Also refer to util/ipmi_sample.c for an example of how these APIs are used.
/*
* ipmi_cmd
* ushort cmd (input): (netfn << 8) + command
* uchar *pdata (input): pointer to ipmi data
* int sdata (input): size of ipmi data
* uchar *presp (output): pointer to response data buffer
* int *sresp (input/output): on input, size of response buffer,
* on output, length of response data
* uchar *cc (output): completion code
* char fdebugcmd(input): flag =1 if debug output desired
* returns 0 if successful, <0 if error
*/
int ipmi_cmd(ushort cmd, uchar *pdata, int sdata, uchar *presp,
int *sresp, uchar *pcc, char fdebugcmd);
/*
* ipmi_cmdraw
* uchar cmd (input): IPMI Command
* uchar netfn (input): IPMI NetFunction
* uchar sa (input): IPMI Slave Address of the MC
* uchar bus (input): BUS of the MC
* uchar lun (input): IPMI LUN
* uchar *pdata (input): pointer to ipmi data
* int sdata (input): size of ipmi data
* uchar *presp (output): pointer to response data buffer
* int *sresp (input/output): on input, size of response buffer,
* on output, length of response data
* uchar *cc (output): completion code
* char fdebugcmd(input): flag =1 if debug output desired
* returns 0 if successful, <0 if error
*/
int ipmi_cmdraw(uchar cmd, uchar netfn, uchar sa, uchar bus, uchar lun,
uchar *pdata, int sdata, uchar *presp,
int *sresp, uchar *pcc, char fdebugcmd);
/*
* ipmi_close_
* Called to close an IPMI session.
* returns 0 if successful, <0 if error
*/
int ipmi_close_(void);
int ipmi_close(void); /*ditto*/
/*-----------------------------------------------------------------*
* These externals are conditionally compiled in ipmicmd.c
ipmi_cmdraw_ia() Intel IMB driver, /dev/imb
ipmi_cmdraw_mv() MontaVista OpenIPMI driver
ipmi_cmdraw_va() VALinux driver
ipmi_cmdraw_ld() LANDesk driver
ipmi_cmdraw_direct() Direct/Driverless KCS or SSIF
ipmi_cmdraw_lan() IPMI LAN
ipmi_cmdraw_lan2() IPMI LANplus (RMCP+ in IPMI 2.0)
*-----------------------------------------------------------------*/
/*
* parse_lan_options
* Parse the IPMI LAN options from the command-line getopt.
* int c (input): command-line option from getopt, one of:
case 'F': force driver type
case 'T': auth type
case 'V': priv level
case 'J': cipher suite
case 'N': nodename
case 'U': username
case 'R': remote password
case 'P': remote password
case 'E': get password from IPMI_PASSWORD environment var
case 'Y': prompt for remote password
case 'Z': set local MC address
* char *optarg (input): command-line argument from getopt
* char fdebug (input): show debug messages if =1, default=0
*/
void parse_lan_options(int c, char *optarg, char fdebug);
/*
* set_lan_options
* Use this routine to set the lan options 'gnode','guser','gpswd', etc.
* This would only be required before opening a new session.
* char *node (input): IP address or nodename of remote node's IPMI LAN
* char *user (input): IPMI LAN username
* char *pswd (input): IPMI LAN password
* int auth (input): IPMI LAN authentication type (1 - 5)
* IPMI_SESSION_AUTHTYPE_NONE 0x00
* IPMI_SESSION_AUTHTYPE_MD2 0x01
* IPMI_SESSION_AUTHTYPE_MD5 0x02
* IPMI_SESSION_AUTHTYPE_PASSWORD 0x04
* IPMI_SESSION_AUTHTYPE_OEM 0x05
* int priv (input): IPMI LAN privilege level (1 - 5)
* IPMI_PRIV_LEVEL_CALLBACK 0x01
* IPMI_PRIV_LEVEL_USER 0x02
* IPMI_PRIV_LEVEL_OPERATOR 0x03
* IPMI_PRIV_LEVEL_ADMIN 0x04
* IPMI_PRIV_LEVEL_OEM 0x05
* int cipher (input): IPMI LAN cipher suite (0 thru 17, default is 3)
* See table 22-19 in the IPMIv2 spec.
* void *addr (input): Socket Address to use (SOCKADDR_T *) if not NULL
* This is only used in itsol.c because it has an
* existing socket open. Default is NULL for this.
* int addr_len (input): length of Address buffer (128 if ipv6, 16 if ipv4)
* returns 0 if successful, <0 if error
*/
int set_lan_options(char *node, char *user, char *pswd, int auth, int priv,
int cipher, void *addr, int addr_len);
int get_lan_options(char *node, char *user, char *pswd, int *auth, int *priv,
int *cipher, void *addr, int *addr_len);
void print_lan_opt_usage(void);
int ipmi_getdeviceid(uchar *presp, int sresp, char fdebugcmd);
/* int ipmi_open(void); * embedded in ipmi_cmd() */
int ipmi_getpicmg(uchar *presp, int sresp, char fdebug);
char *show_driver_type(int idx);
int set_driver_type(char *tag);
int get_driver_type(void);
int nodeislocal(char *nodename);
/* These *_mc routines are used to manage changing the mc.
* The local mc (mymc) may be changed via -Z, and
* the remote mc (mc) may be changed with -m. */
void ipmi_set_mc(uchar bus, uchar sa, uchar lun, uchar type);
void ipmi_get_mc(uchar *bus, uchar *sa, uchar *lun, uchar *type);
void ipmi_restore_mc(void);
void ipmi_set_mymc(uchar bus, uchar sa, uchar lun, uchar type);
void ipmi_get_mymc(uchar *bus, uchar *sa, uchar *lun, uchar *type);
/* ipmi_cmdraw_mc and ipmi_cmd_mc are used in cases where the mc may
* have been changed via ipmi_set_mc. */
int ipmi_cmdraw_mc(uchar cmd, uchar netfn,
uchar *pdata, int sdata, uchar *presp,
int *sresp, uchar *pcc, char fdebugcmd);
int ipmi_cmd_mc(ushort icmd, uchar *pdata, int sdata, uchar *presp,
int *sresp, uchar *pcc, char fdebugcmd);
/* ipmi_sendrecv is a wrapper for ipmi_cmdraw which maps to ipmitool syntax */
int ipmi_sendrecv(struct ipmi_rq * req, uchar *rsp, int *rsp_len);
/* other common subroutines */
char * decode_rv(int rv); /*ipmicmd.c*/
char * decode_cc(ushort icmd, int cc);
void dump_buf(char *tag,uchar *pbuf,int sz, char fshowascii);
int get_lan_channel(uchar chstart, uchar *chan);
void show_fru_picmg(uchar *pdata, int dlen); /* ifru_picmg.c*/
/* show_outcome outputs the meaning of the return code. */
void show_outcome(char *prog, int ret);
/* these log routines are primarily for the isol debug log */
FILE *open_log(char *mname);
void close_log(void);
void flush_log(void);
void print_log( char *pattn, ... );
void dump_log(FILE *fp,char *tag,uchar *pbuf,int sz, char fshowascii);
void logmsg( char *pname, char *pattn, ... );
#ifdef WIN32
/* Implement the Linux strncasecmp for Windows. */
int strncasecmp(const char *s1, const char *s2, int n);
#endif
const char *val2str(ushort val, const struct valstr *vs); /*ipmilanplus.c*/
const char * oemval2str(ushort oem, uchar val, const struct oemvalstr *vs);
void set_debug(void); /*used only by oem_sun.c*/
void set_iana(int iana); /*ipmicmd.c*/
void set_mfgid(uchar *devid, int len);
void get_mfgid(int *pvend, int *pprod);
void get_devid_ver(uchar *bmaj, uchar *bmin, uchar *iver);
char *get_nodename(void);
char is_remote(void);
void show_devid(uchar b1, uchar b2, uchar i1, uchar i2);
int set_max_kcs_loops(int ms); /* ipmicmd.c, calls ipmidir.c if ok */
/* These common subroutines are in subs.c */
int str_icmp(char *s1, char *s2); /*used internally in ipmicmd.c*/
char * strdup_(const char *instr); /*wrapper for strdup, supports WIN32*/
int strlen_(const char *s); /*wrapper for strlen, avoids compile warnings*/
uchar htoi(char *inhex);
void os_usleep(int s, int u);
char *get_iana_str(int mfg); /*subs.c*/
int get_errno(void); /*subs.c*/
const char * buf2str(uchar * buf, int len); /*subs.c*/
int str2uchar(char *str_in, uchar *uchr_out);
uchar atob(char *str_in); /* calls str2uchar*/
void atoip(uchar *array,char *instr);
int get_system_info(uchar parm, char *pbuf, int *szbuf); /*subs.c*/
int set_system_info(uchar parm, uchar *pbuf, int szbuf); /*subs.c*/
int ipmi_reserved_user(int vend, int userid); /*subs.c*/
/* from mem_if.c */
int get_BiosVersion(char *str);
/* See util/isensor.h for SDR cache routines. */
/* See util/ievents.h for sensor_type_desc, sel_opts, decode_sel routines. */
--------------------------
10.0 RELATED INFORMATION
--------------------------
10.1 History
History of ipmiutil:
This project started in October 2001 as part of the Carrier Grade Linux effort.
It was then known as 'panicsel' and included a kernel patch to write a Linux
panic event to the IPMI firmware log, as well as utilities.
This code was first included in MontaVista CGE Linux 2.1 in July 2002.
The panicsel functionality was included in OSDL CGL 1.0 and 2.0 requirements.
The kernel panic functionality was included in the OpenIPMI driver for 2.6
Linux kernels. Compile flags for Windows 2000 & 2003 support were added in
Jan 2004.
In August 2004, the project was moved from panicsel.sf.net to ipmiutil.sf.net.
The new name more clearly reflects the purpose of the project in its current
state. In November 2004, support for the FreeIPMI library was added.
A Linux rpm and a Windows setup package for ipmiutil is included on the
Resource CD with Intel carrier-grade servers.
The ipmiutil (or panicsel) rpm is known to be included in the following
distributions: MontaVista CGE 2.1/3.0/3.1/4.0, SuSE SLES9, Red Flag 5.0
10.2 Links
Links with information related to the IPMI Management Utilities project.
ipmiutil project, sourceforge http://ipmiutil.sourceforge.net (current)
panicsel project, sourceforge http://panicsel.sourceforge.net (old)
IPMI Specification http://www.intel.com/design/servers/ipmi/index.htm
OSDL Carrier Grade Linux http://www.osdl.org/lab_activities/carrier_grade_linux/
Intel imb driver source http://downloadfinder.intel.com/scripts-df-external/Product_Search.asp?Prod_nm=ipmi*driver*source
Intel imb driver for Windows http://downloadfinder.intel.com/scripts-df-external/Product_Search.aspx?Prod_nm=imb+driver
OpenIPMI project http://sourceforge.net/projects/openipmi/
by Corey Minyard of MontaVista (home= http://openipmi.sourceforge.net)
ipmitools project by San Mehat http://sourceforge.net/projects/ipmitools/
valinux IPMI driver http://cvs.sf.net/cgi-bin/viewcvs.cgi/ipmitools/ipmitools/kernel/kcs/patches/2.4.x/
GNU FreeIPMI library project http://www.gnu.org/software/freeipmi/
LANDesk IPMI driver/daemon http://www.landesk.com/Support/ (or see
Intel System Resource CD for Intel servers)
lm-sensors project http://secure.netroedge.com/~lm78/
dmidecode project http://www.nongnu.org/dmidecode/
IPMI vendor/mfg IDs http://www.iana.org/assignments/enterprise-numbers
|