1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280
|
'\"
'\" Copyright (c) 1995 DSC Technologies Corporation
'\"
'\" See the file "license.terms" for information on usage and redistribution
'\" of this file, and for a DISCLAIMER OF ALL WARRANTIES.
'\"
'\" @(#) spintime.n
'\"
.so man.macros
.HS spintime iwid
.BS
'\" Note: do not modify the .SH NAME line immediately below!
.SH NAME
spintime \- Create and manipulate time spinner widgets
.SH SYNOPSIS
\fBspintime\fI \fIpathName \fR?\fIoptions\fR?
.SH "INHERITANCE"
itk::Widget <- Spintime
.SH "STANDARD OPTIONS"
.LP
.nf
.ta 4c 8c 12c
\fBbackground\fR \fBcursor\fR \fBforeground\fR \fBhighlightColor\fR
\fBhighlightThickness\fR \fBrelief\fR \fBselectBackground\fR \fBselectBorderWidth\fR
\fBselectForeground\fR
.fi
.LP
See the "options" manual entry for details on the standard options.
.SH "ASSOCIATED OPTIONS"
.LP
.nf
.ta 4c 8c 12c
\fBtextBackground\fR \fBtextFont\fR
.fi
.LP
See the "entryfield" manual entry for details on the above associated options.
.LP
.nf
.ta 4c 8c 12c
\fBlabelFont\fR \fBlabelMargin\fR
.fi
.LP
See the "labeledwidget" manual entry for details on the above associated
options.
.LP
.nf
.ta 4c 8c 12c
\fBstep\fR
.fi
.LP
See the "spinint" manual entry for details on the above associated options.
.LP
.nf
.ta 4c 8c 12c
\fBarrowOrient\fR \fBrepeatDelay\fR \fBrepeatInterval\fR
.fi
.LP
See the "spinner" manual entry for details on the above associated options.
.SH "WIDGET-SPECIFIC OPTIONS"
.LP
.nf
Name: \fBlabelPos\fR
Class: \fBPosition\fR
Command-Line Switch: \fB-labelpos\fR
.fi
.IP
Specifies the position of the label along the sides of the various
spinners: \fBn\fR, \fBe\fR, \fBs\fR, or \fBw\fR. The default is w.
.LP
.nf
Name: \fBhourLabel\fR
Class: \fBText\fR
Command-Line Switch: \fB-hourlabel\fR
.fi
.IP
Specifies the text of the label for the hour spinner. The default is "Hour".
.LP
.nf
Name: \fBhourOn\fR
Class: \fBhourOn\fR
Command-Line Switch: \fB-houron\fR
.fi
.IP
Specifies whether or not to display the hour spinner in any of the forms
acceptable to \fBTcl_GetBoolean\fR. The default is true.
.LP
.nf
Name: \fBhourWidth\fR
Class: \fBWidth\fR
Command-Line Switch: \fB-hourwidth\fR
.fi
.IP
Specifies the width of the hour spinner in any of the forms acceptable to
\fBTcl_GetPixels\fR. The default is 3 pixels.
.LP
.nf
Name: \fBmilitaryOn\fR
Class: \fBmilitaryOn\fR
Command-Line Switch: \fB-militaryon\fR
.fi
.IP
Specifies use of a 24 hour clock for hour display in any of the forms
acceptable to \fBTcl_GetBoolean\fR. The default is true.
.LP
.nf
Name: \fBminuteLabel\fR
Class: \fBText\fR
Command-Line Switch: \fB-minutelabel\fR
.fi
.IP
Specifies the text of the label for the minute spinner. The default is
"Minute".
.LP
.nf
Name: \fBminuteOn\fR
Class: \fBminuteOn\fR
Command-Line Switch: \fB-minuteon\fR
.fi
.IP
Specifies whether or not to display the minute spinner in any of the forms
acceptable to \fBTcl_GetBoolean\fR. The default is true.
.LP
.nf
Name: \fBminuteWidth\fR
Class: \fBWidth\fR
Command-Line Switch: \fB-minutewidth\fR
.fi
.IP
Specifies the width of the minute spinner in any of the forms acceptable to
\fBTcl_GetPixels\fR. The default is 3 pixels.
.LP
.nf
Name: \fBorient\fR
Class: \fBOrient\fR
Command-Line Switch: \fB-orient\fR
.fi
.IP
Specifies the orientation of the hour, minute, and second spinners: \fBvertical\fR or \fBhorizontal\fR. The default is horizontal.
.LP
.nf
Name: \fBsecondLabel\fR
Class: \fBText\fR
Command-Line Switch: \fB-secondlabel\fR
.fi
.IP
Specifies the text of the label for the second spinner. The default is
"Second"
.LP
.nf
Name: \fBsecondOn\fR
Class: \fBsecondOn\fR
Command-Line Switch: \fB-secondon\fR
.fi
.IP
Specifies whether or not to display the second spinner in any of the forms
acceptable to \fBTcl_GetBoolean\fR. The default is true.
.LP
.nf
Name: \fBsecondWidth\fR
Class: \fBWidth\fR
Command-Line Switch: \fB-secondwidth\fR
.fi
.IP
Specifies the width of the second spinner in any of the forms acceptable to
\fBTcl_GetPixels\fR. The default is 3 pixels.
.LP
.nf
Name: \fBtimeMargin\fR
Class: \fBMargin\fR
Command-Line Switch: \fB-timemargin\fR
.fi
.IP
Specifies the margin space between the hour, minute, and second spinners is
any of the forms accpetable to \fBTcl_GetPixels\fR. The default is 1 pixel.
.LP
.nf
.BE
.SH DESCRIPTION
.PP
The \fBspintime\fR command creates a set of spinners for use in time value
entry. The set includes an hour, minute, and second spinner widget.
.SH "METHODS"
.PP
The \fBspintime\fR command creates a new Tcl command whose
name is \fIpathName\fR. This
command may be used to invoke various
operations on the widget. It has the following general form:
.DS C
\fIpathName option \fR?\fIarg arg ...\fR?
.DE
\fIOption\fR and the \fIarg\fRs
determine the exact behavior of the command. The following
commands are possible for spintime widgets:
.SH "WIDGET-SPECIFIC METHODS"
.TP
\fIpathName \fBcget\fR \fIoption\fR
Returns the current value of the configuration option given
by \fIoption\fR.
\fIOption\fR may have any of the values accepted by the \fBspintime\fR
command.
.TP
\fIpathName\fR \fBclear\fR
Delete the contents of all spinner components.
.TP
\fIpathName\fR \fBconfigure\fR ?\fIoption\fR? ?\fIvalue option value ...\fR?
Query or modify the configuration options of the widget.
If no \fIoption\fR is specified, returns a list describing all of
the available options for \fIpathName\fR (see \fBTk_ConfigureInfo\fR for
information on the format of this list). If \fIoption\fR is specified
with no \fIvalue\fR, then the command returns a list describing the
one named option (this list will be identical to the corresponding
sublist of the value returned if no \fIoption\fR is specified). If
one or more \fIoption\-value\fR pairs are specified, then the command
modifies the given widget option(s) to have the given value(s); in
this case the command returns an empty string.
\fIOption\fR may have any of the values accepted by the \fBspintime\fR
command.
.TP
\fIpathName\fR \fBdelete\fR \fIcomponent\fR \fIfirst\fR ?\fIlast\fR?
Delete one or more characters of the specified \fIcomponent\fR,
where \fIcomponent\fR can be \fBhour\fR, \fBminute\fR, or \fBsecond\fR.
\fIFirst\fR is the index of the first character to delete, and \fIlast\fR
is the index of the character just after the last one to delete.
.TP
\fIpathName\fR \fBget\fR \fI?component?\fR
Get returns the value for the speicifed component: \fBhour\fR, \fBminute\fR, or
\fBsecond\fR. Without parameters the command returns the all three values as
a list.
.TP
\fIpathName\fR \fBinsert\fR \fIcomponent\fR \fIindex\fR \fIstring\fR
Inserts the characters of \fIstring\fR just before the character indicated
by \fIindex\fR in the \fIcomponent\fR, where \fIcomponent\fR can
be \fBhour\fR, \fBminute\fR, or \fBsecond\fR.
.ta 4c
.SH "COMPONENTS"
.LP
.nf
Name: \fBhour\fR
Class: \fBSpinint\fR
.fi
.IP
The hour component is the hour spinner of the time spinner. See the
SpinInt widget manual entry for details on the hour component item.
.LP
.nf
Name: \fBminute\fR
Class: \fBSpinint\fR
.fi
.IP
The minute component is the minute spinner of the time spinner. See
the SpinInt widget manual entry for details on the minute component item.
.LP
.nf
Name: \fBsecond\fR
Class: \fBSpinint\fR
.fi
.IP
The second component is the second spinner of the time spinner. See the
SpinInt widget manual entry for details on the second component item.
.fi
.SH EXAMPLE
.DS
spintime .st
pack .st -padx 10 -pady 10
.DE
.SH AUTHOR
Sue Yockey
.DE
Mark L. Ulferts
.SH KEYWORDS
spintime, spinint, spinner, entryfield, entry, widget
|