1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118
|
## -*- config -*-
###########################################################################
## This configuration file is for Demeter version 0.9.21.
##
## Demeter is copyright (c) 2007-2016 Bruce Ravel
## http://bruceravel.github.io/home
##
## Ifeffit is copyright (c) 1992-2016 Matt Newville
## https://github.com/newville/ifeffit
##
## The latest version of Demeter can always be found at
## http://bruceravel.github.io/demeter
##
## -------------------------------------------------------------------
## All rights reserved. This program is free software; you can
## redistribute it and/or modify it provided that the above notice
## of copyright, these terms of use, and the disclaimer of
## warranty below appear in the source code and documentation, and
## that none of the names of Argonne National Laboratory, The
## University of Chicago, University of Washington, or the authors
## appear in advertising or endorsement of works derived from this
## software without specific prior written permission from all
## parties.
##
## THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
## EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
## OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
## NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
## HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
## WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
## FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
## OTHER DEALINGS IN THIS SOFTWARE.
## -------------------------------------------------------------------
###########################################################################
## This file contains the configuration groups for analysis chores in Demeter
######################################################################
section=peakfit
section_description
These variables determine details of Demeter's peak fitting analysis
system.
variable=backend
type=list
options=larch ifeffit fityk
default=ifeffit
description
This tells Demeter which peak fitting backend to use. This
parameter is not currently in use as the fityk backend is still
experimental. It can be employed in a script by specifying the
backend when creating the PeakFit object. Fityk is not available in
Athena at this time.
variable=emin
type=real
default=-20
restart=1
units=eV (relative to e0)
description
The default lower bound of an analysis in energy.
variable=emax
type=real
default=80
restart=1
units=eV (relative to e0)
description
The default lower bound of an analysis in energy.
variable=plot_during
type=boolean
onvalue=1
offvalue=0
default=false
description
When true, a plot will be made at every step during a sequence of fits.
######################################################################
section=pca
section_description
These variables determine details of Demeter's principle component
analysis system.
variable=emin
type=real
default=-20
restart=1
units=eV (relative to e0)
description
The default lower bound of an analysis in energy.
variable=emax
type=real
default=80
restart=1
units=eV (relative to e0)
description
The default lower bound of an analysis in energy.
variable=kmin
type=real
default=3
restart=1
units=inverse Angstroms
description
The default lower bound of an analysis in k.
variable=kmax
type=real
default=12
restart=1
units=inverse Angstroms
description