1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76
|
## -*- config -*-
###########################################################################
## This configuration file is for Demeter version 0.9.21.
##
## Demeter is copyright (c) 2007-2016 Bruce Ravel
## http://bruceravel.github.io/home
##
## Ifeffit is copyright (c) 1992-2016 Matt Newville
## https://github.com/newville/ifeffit
##
## The latest version of Demeter can always be found at
## http://bruceravel.github.io/demeter/
##
## -------------------------------------------------------------------
## All rights reserved. This program is free software; you can
## redistribute it and/or modify it provided that the above notice
## of copyright, these terms of use, and the disclaimer of
## warranty below appear in the source code and documentation, and
## that none of the names of Argonne National Laboratory, The
## University of Chicago, University of Washington, or the authors
## appear in advertising or endorsement of works derived from this
## software without specific prior written permission from all
## parties.
##
## THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
## EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
## OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
## NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
## HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
## WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
## FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
## OTHER DEALINGS IN THIS SOFTWARE.
## -------------------------------------------------------------------
###########################################################################
## This file contains the bft configuration group for Demeter
######################################################################
section=bft
section_description
These parameters determine how backward Fourier transforms
are done by Demeter.
variable=dr
type=real
default=0.0
units=Angstroms
description
The default width of the window sill used in the backward Fourier
transform. 0 is used if this is set to less than 0.
variable=rwindow
type=list
default=hanning
options=hanning kaiser-bessel welch parzen sine
description
The default window type to use for the backward Fourier transform.
variable=rmin
type=real
default=1
units=Angstroms
description
The default value for the lower range of the backward Fourier
transform.
variable=rmax
type=real
default=3
units=Angstroms
description
The default value for the upper range of the backward Fourier
transform.
|