1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287
|
## -*- config -*-
###########################################################################
## This configuration file is for Demeter version 0.9.21.
##
## Demeter is copyright (c) 2007-2016 Bruce Ravel
## http://bruceravel.github.io/home
##
## Ifeffit is copyright (c) 1992-2016 Matt Newville
## https://github.com/newville/ifeffit
##
## The latest version of Demeter can always be found at
## http://bruceravel.github.io/demeter/
##
## -------------------------------------------------------------------
## All rights reserved. This program is free software; you can
## redistribute it and/or modify it provided that the above notice
## of copyright, these terms of use, and the disclaimer of
## warranty below appear in the source code and documentation, and
## that none of the names of Argonne National Laboratory, The
## University of Chicago, University of Washington, or the authors
## appear in advertising or endorsement of works derived from this
## software without specific prior written permission from all
## parties.
##
## THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
## EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
## OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
## NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
## HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
## WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
## FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
## OTHER DEALINGS IN THIS SOFTWARE.
## -------------------------------------------------------------------
###########################################################################
## This file contains the Hephaestus configuration group
######################################################################
section=hephaestus
section_description
These variables determine the behavior of Hephaestus.
variable=resource
type=list
options=Elam McMaster Shaltout Henke Chantler CL
default=Elam
description
The data resource to use for most calculations. Note that the CL
resource is always used in the F1F2 utility while the edge and line
energies from the Elam resource are always used in the edge finder,
line finder and absorption utilities.
variable=enable_beamline
type=boolean
onvalue=1
offvalue=0
default=false
restart=1
description
Enable or disable beamline customizations.
variable=beamline_name
type=string
default=BL
restart=1
description
The name of your beamline. Keep it short! This has to fit on the
button.
variable=beamline_emin
type=real
default=4500
units=eV
description
The lower bound of the energy range of yor beamline.
variable=beamline_emax
type=real
default=23000
units=eV
description
The upper bound of the energy range of yor beamline.
variable=beamline_show_m
type=boolean
onvalue=1
offvalue=0
default=false
restart=1
description
Display the button for beamline customization for M edges
# variable=units
# type=list
# options=energy wavelength
# default=energy
# description
# This specifies the default units to use to present energy values.
variable=xsec
type=list
options=full photo coherent incoherent
default=full
description
This sets the default cross-section to use in all calculations. The
options are to use the photoelectric, coherent, or incoherent
cross-section or the sum of all three. A change in this parameter
will take effect the next time a calculation is performed.
variable=filter_width
type=real
default=30
units=energy
description
This is the Gaussian linewidth to use in filter plots.
variable=filter_offset
type=positive integer
default=3
description
This parameter is used to determine appropriate filter for an L3
edge -- a filter must have its K edge (filter_offset*filter_width)
above the Lalpha1 line of the absorber
variable=formula_energy
type=absolute energy
default=9000
units=energy
restart=1
description
The initial energy value in the Formulas utility
variable=stepwidth
type=real
default=0.001
description
This parameter sets the width in energy above and below an edge
which is used to compute an edge step in the formulas tool in
Hephaestus. If the value is any number greater than or equal to 1,
then that is used as the energy width. So if the value is 50, then
the step will be computed by comaring the absorption at +/- 50 eV.
If the value is less than 1, then it will be multiplied by the
specified energy to yield the width. The default value of 0.001
says that the width is 1% of the specified energy. For Fe K at
7112, the width will be 7.112 eV. If it is less than 0, it will be
reset to 0.001.
variable=ion_energy
type=absolute energy
default=9000
units=energy
restart=1
description
The initial energy value in the Ion Chambers utility
variable=ion_length
type=list
options=3.3 6.6 10 15 30 45 60
default=15
units=cm
restart=1
description
The intial value for chamber length in the Ion Chambers utility
variable=ion_custom
type=real
default=20
units=cm
restart=1
description
The initial value for the custom ion chamber length in the Ion
Chambers utility
variable=ion_gas1
type=list
options=He N2 Ne Ar Kr Xe
default=N2
restart=1
description
The intial type for the primary ion chamber gas. The initial
secondary gas is always He.
variable=ion_pressure
type=positive integer
default=760
maxint=2300
units=torr
restart=1
description
The initial pressure for the Ion Chambers utility in torr. 760 torr
is 1013.25 millibars or 1 atmosphere. 2300 torr is 3066.41
millibars or 3.02 atmospheres. Conversions between units within
hephaestus will be rounded to the nearest integer for use with the
slider widget.
## atm would be nice, but Wx::Slider takes an integer line size, so
## not enough granularity
variable=ion_pressureunits
type=list
options=torr mbar
default=torr
maxint=2300
description
The units of pressure in the Ion Chambers utility. 760 torr is
1013.25 millibars or 1 atmosphere. 2300 torr is 3066.41 millibars
or 3.02 atmospheres. Conversions between units within hephaestus
will be rounded to the nearest integer for use with the slider
widget.
variable=ion_gain
type=positive integer
default=8
minint=4
maxint=12
restart=1
description
The initial value of the gain in the Ion Chambers utility
variable=find_energy
type=absolute energy
default=8978
units=energy
restart=1
description
The energy value in the Edge Finder utility
variable=find_harmonic
type=positive integer
minint=1
maxint=3
default=1
restart=1
description
The initial choice for harmonic in the Edge Finder utility
variable=line_energy
type=absolute energy
default=8045
units=energy
restart=1
description
The energy value in the Line Finder utility
variable=f1f2_emin
type=absolute energy
default=3000
units=energy
restart=1
description
The intial value for the minimum energy in the Anomalous Scattering utility
variable=f1f2_emax
type=absolute energy
default=7000
units=energy
restart=1
description
The intial value for the maximum energy in the Anomalous Scattering utility
variable=f1f2_grid
type=positive integer
default=5
units=energy
restart=1
description
The intial value for the energy grid size in the Anomalous Scattering utility
variable=standards_emin
type=absolute energy
default=-30
units=energy
restart=1
description
The intial value for the lower energy of a standards plot.
variable=standards_emax
type=absolute energy
default=100
units=energy
restart=1
description
The intial value for the upper energy of a standards plot.
|