1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67
|
## -*- config -*-
###########################################################################
## This configuration file is for Demeter version 0.9.21.
##
## Demeter is copyright (c) 2007-2016 Bruce Ravel
## http://bruceravel.github.io/home
##
## Ifeffit is copyright (c) 1992-2016 Matt Newville
## https://github.com/newville/ifeffit
##
## The latest version of Demeter can always be found at
## http://bruceravel.github.io/demeter/
##
## -------------------------------------------------------------------
## All rights reserved. This program is free software; you can
## redistribute it and/or modify it provided that the above notice
## of copyright, these terms of use, and the disclaimer of
## warranty below appear in the source code and documentation, and
## that none of the names of Argonne National Laboratory, The
## University of Chicago, University of Washington, or the authors
## appear in advertising or endorsement of works derived from this
## software without specific prior written permission from all
## parties.
##
## THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
## EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
## OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
## NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
## HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
## WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
## FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
## OTHER DEALINGS IN THIS SOFTWARE.
## -------------------------------------------------------------------
###########################################################################
## This file contains the data watcher configuration group for Demeter
######################################################################
section=watcher
section_description
These variables set parameters related to data watching capabilities
in Demeter
variable=interval
type=positive integer
default=120
minint=10
maxint=9999
units=seconds
description
The default value for the time interval on which to check for new
scans
variable=fuzz
type=positive integer
default=10
minint=1
maxint=9999
units=bytes
description
The default value for the variability in scan file size in bytes.
That is, a scan will be considered to be complete is its file size
is within this number of bytes of earlier files inported while the
timer has been running.
|