1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531
|
# SNMP::Info::Layer3::Enterasys - SNMP Interface to Enterasys devices
# $Id$
#
# Copyright (c) 2008 Eric Miller
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions are met:
#
# * Redistributions of source code must retain the above copyright notice,
# this list of conditions and the following disclaimer.
# * Redistributions in binary form must reproduce the above copyright
# notice, this list of conditions and the following disclaimer in the
# documentation and/or other materials provided with the distribution.
# * Neither the name of the University of California, Santa Cruz nor the
# names of its contributors may be used to endorse or promote products
# derived from this software without specific prior written permission.
#
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
# LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
# POSSIBILITY OF SUCH DAMAGE.
package SNMP::Info::Layer3::Enterasys;
use strict;
use Exporter;
use SNMP::Info::MAU;
use SNMP::Info::LLDP;
use SNMP::Info::CDP;
use SNMP::Info::Layer3;
@SNMP::Info::Layer3::Enterasys::ISA = qw/SNMP::Info::MAU SNMP::Info::LLDP
SNMP::Info::CDP SNMP::Info::Layer3
Exporter/;
@SNMP::Info::Layer3::Enterasys::EXPORT_OK = qw//;
use vars qw/$VERSION $DEBUG %GLOBALS %FUNCS $INIT %MIBS %MUNGE/;
$VERSION = '2.06';
%MIBS = (
%SNMP::Info::Layer3::MIBS, %SNMP::Info::CDP::MIBS,
%SNMP::Info::LLDP::MIBS, %SNMP::Info::MAU::MIBS,
'ENTERASYS-OIDS-MIB' => 'etsysOidDevice',
);
%GLOBALS = (
%SNMP::Info::Layer3::GLOBALS, %SNMP::Info::CDP::GLOBALS,
%SNMP::Info::LLDP::GLOBALS, %SNMP::Info::MAU::GLOBALS,
'mac' => 'dot1dBaseBridgeAddress',
);
%FUNCS = (
%SNMP::Info::Layer3::FUNCS, %SNMP::Info::CDP::FUNCS,
%SNMP::Info::LLDP::FUNCS, %SNMP::Info::MAU::FUNCS,
);
%MUNGE = (
%SNMP::Info::Layer3::MUNGE, %SNMP::Info::CDP::MUNGE,
%SNMP::Info::LLDP::MUNGE, %SNMP::Info::MAU::MUNGE,
);
sub model {
my $enterasys = shift;
my $id = $enterasys->id();
unless ( defined $id ) {
print
" SNMP::Info::Layer3::Enterasys::model() - Device does not support sysObjectID\n"
if $enterasys->debug();
return;
}
my $model = &SNMP::translateObj($id);
$model =~ s/^etsysOidDev//i;
$model =~ s/^etsysOidPhy//i;
return $id unless defined $model;
return $model;
}
sub vendor {
return 'enterasys';
}
sub os {
return 'enterasys';
}
sub os_ver {
my $enterasys = shift;
my $descr = $enterasys->description();
return unless defined $descr;
if ( $descr =~ m/\bRev ([\d.]*)/ ) {
return $1;
}
return;
}
# Use ifName as it is used for CDP and LLDP.
sub interfaces {
my $enterasys = shift;
my $partial = shift;
# We need the original ifName, SUPER:: would give us a method definition
# in a higher class, we could use orig_ but just call the MIB leaf since
# that's what we really want anyway.
return $enterasys->ifName($partial)
|| $enterasys->i_description($partial);
}
sub i_ignore {
my $enterasys = shift;
my $partial = shift;
my $interfaces = $enterasys->i_type($partial) || {};
my %i_ignore;
foreach my $if ( keys %$interfaces ) {
if ( $interfaces->{$if} =~ /(rs232|tunnel|loopback|\blo\b|null)/i ) {
$i_ignore{$if}++;
}
}
return \%i_ignore;
}
sub i_duplex {
my $enterasys = shift;
my $partial = shift;
return $enterasys->mau_i_duplex($partial);
}
sub i_duplex_admin {
my $enterasys = shift;
my $partial = shift;
return $enterasys->mau_i_duplex_admin($partial);
}
# Normal BRIDGE-MIB has issues on some devices, duplicates and
# non-increasing oids, Use Q-BRIDGE-MIB for macsuck
sub fw_mac {
my $enterasys = shift;
my $partial = shift;
return $enterasys->qb_fw_mac($partial);
}
sub fw_port {
my $enterasys = shift;
my $partial = shift;
return $enterasys->qb_fw_port($partial);
}
# Use CDP and/or LLDP
#
# LLDP table timefilter implementation continuously increments when walked
# and we may never reach the end of the table. This behavior can be
# modified with the "set snmp timefilter break disable" command,
# unfortunately it is not the default. Query with a partial value of zero
# which means no time filter.
sub hasCDP {
my $enterasys = shift;
return $enterasys->hasLLDP() || $enterasys->SUPER::hasCDP();
}
sub c_ip {
my $enterasys = shift;
my $partial = shift;
my $cdp = $enterasys->SUPER::c_ip($partial) || {};
my $lldp = $enterasys->lldp_ip(0) || {};
my %c_ip;
foreach my $iid ( keys %$cdp ) {
my $ip = $cdp->{$iid};
next unless defined $ip;
$c_ip{$iid} = $ip;
}
foreach my $iid ( keys %$lldp ) {
my $ip = $lldp->{$iid};
next unless defined $ip;
$c_ip{$iid} = $ip;
}
return \%c_ip;
}
sub c_if {
my $enterasys = shift;
my $partial = shift;
my $lldp = $enterasys->lldp_if(0) || {};
my $cdp = $enterasys->SUPER::c_if($partial) || {};
my %c_if;
foreach my $iid ( keys %$cdp ) {
my $if = $cdp->{$iid};
next unless defined $if;
$c_if{$iid} = $if;
}
foreach my $iid ( keys %$lldp ) {
my $if = $lldp->{$iid};
next unless defined $if;
$c_if{$iid} = $if;
}
return \%c_if;
}
sub c_port {
my $enterasys = shift;
my $partial = shift;
my $lldp = $enterasys->lldp_port(0) || {};
my $cdp = $enterasys->SUPER::c_port($partial) || {};
my %c_port;
foreach my $iid ( keys %$cdp ) {
my $port = $cdp->{$iid};
next unless defined $port;
$c_port{$iid} = $port;
}
foreach my $iid ( keys %$lldp ) {
my $port = $lldp->{$iid};
next unless defined $port;
$c_port{$iid} = $port;
}
return \%c_port;
}
sub c_id {
my $enterasys = shift;
my $partial = shift;
my $lldp = $enterasys->lldp_id(0) || {};
my $cdp = $enterasys->SUPER::c_id($partial) || {};
my %c_id;
foreach my $iid ( keys %$cdp ) {
my $id = $cdp->{$iid};
next unless defined $id;
$c_id{$iid} = $id;
}
foreach my $iid ( keys %$lldp ) {
my $id = $lldp->{$iid};
next unless defined $id;
$c_id{$iid} = $id;
}
return \%c_id;
}
sub c_platform {
my $enterasys = shift;
my $partial = shift;
my $lldp = $enterasys->lldp_rem_sysdesc(0) || {};
my $cdp = $enterasys->SUPER::c_platform($partial) || {};
my %c_platform;
foreach my $iid ( keys %$cdp ) {
my $platform = $cdp->{$iid};
next unless defined $platform;
$c_platform{$iid} = $platform;
}
foreach my $iid ( keys %$lldp ) {
my $platform = $lldp->{$iid};
next unless defined $platform;
$c_platform{$iid} = $platform;
}
return \%c_platform;
}
1;
__END__
=head1 NAME
SNMP::Info::Layer3::Enterasys - SNMP Interface to Enterasys Network Devices
=head1 AUTHOR
Eric Miller
=head1 SYNOPSIS
# Let SNMP::Info determine the correct subclass for you.
my $enterasys = new SNMP::Info(
AutoSpecify => 1,
Debug => 1,
DestHost => 'myswitch',
Community => 'public',
Version => 1
)
or die "Can't connect to DestHost.\n";
my $class = $enterasys->class();
print "SNMP::Info determined this device to fall under subclass : $class\n";
=head1 DESCRIPTION
Provides abstraction to the configuration information obtainable from an
Enterasys device through SNMP.
For speed or debugging purposes you can call the subclass directly, but not
after determining a more specific class using the method above.
my $enterasys = new SNMP::Info::Layer3::Enterasys(...);
=head2 Inherited Classes
=over
=item SNMP::Info::MAU
=item SNMP::Info::LLDP
=item SNMP::Info::CDP
=item SNMP::Info::Layer3
=back
=head2 Required MIBs
=over
=item F<ENTERASYS-OIDS-MIB>
=back
=head2 Inherited MIBs
See L<SNMP::Info::MAU/"Required MIBs"> for its MIB requirements.
See L<SNMP::Info::LLDP/"Required MIBs"> for its MIB requirements.
See L<SNMP::Info::CDP/"Required MIBs"> for its MIB requirements.
See L<SNMP::Info::Layer3/"Required MIBs"> for its MIB requirements.
=head1 GLOBALS
These are methods that return scalar value from SNMP
=over
=item $enterasys->model()
Returns model type. Checks $enterasys->id() against the
F<ENTERASYS-OIDS-MIB>.
=item $enterasys->vendor()
Returns enterasys
=item $enterasys->os()
Returns enterasys
=item $enterasys->os_ver()
Returns os version extracted from C<sysDescr>
=item $enterasys->mac()
Returns base mac
(C<dot1dBaseBridgeAddress>)
=back
=head2 Overrides
=over
=back
=head2 Globals imported from SNMP::Info::MAU
See documentation in L<SNMP::Info::MAU/"GLOBALS"> for details.
=head2 Globals imported from SNMP::Info::LLDP
See documentation in L<SNMP::Info::LLDP/"GLOBALS"> for details.
=head2 Globals imported from SNMP::Info::CDP
See documentation in L<SNMP::Info::CDP/"GLOBALS"> for details.
=head2 Globals imported from SNMP::Info::Layer3
See documentation in L<SNMP::Info::Layer3/"GLOBALS"> for details.
=head1 TABLE METHODS
These are methods that return tables of information in the form of a reference
to a hash.
=head2 Overrides
=over
=item $enterasys->interfaces()
Mapping between the Interface Table Index (iid) and the physical port name.
=item $enterasys->i_ignore()
Returns reference to hash. Creates a key for each IID that should be ignored.
Currently looks for rs232, tunnel,loopback,lo,null from
$enterasys->interfaces()
=item $enterasys->i_duplex()
See documentation for mau_i_duplex() in L<SNMP::Info::MAU/"TABLE METHODS">.
=item $enterasys->i_duplex_admin()
See documentation for mau_i_duplex_admin() in
L<SNMP::Info::MAU/"TABLE METHODS">.
=item $enterasys->fw_mac()
Returns reference to hash of forwarding table MAC Addresses.
=item $enterasys->fw_port()
Returns reference to hash of forwarding table entries port interface
identifier (iid).
(C<dot1qTpFdbPort>)
=back
=head2 Topology information
Based upon the firmware version Enterasys devices may support Cabletron
Discovery Protocol (CTRON CDP), Cisco Discovery Protocol (CDP), Link Layer
Discovery Protocol (LLDP), or all. This module currently supports CDP and
LLDP, but not CTRON CDP. These methods will query both CDP and LLDP and
return the combination of all information. As a result, there may be
identical topology information returned from the two protocols
causing duplicate entries. It is the calling program's responsibility to
identify any duplicate entries and remove duplicates if necessary.
=over
=item $enterasys->hasCDP()
Returns true if the device is running either CDP or LLDP.
=item $enterasys->c_if()
Returns reference to hash. Key: iid Value: local device port (interfaces)
=item $enterasys->c_ip()
Returns reference to hash. Key: iid Value: remote IPv4 address
If multiple entries exist with the same local port, c_if(), with the same IPv4
address, c_ip(), it may be a duplicate entry.
If multiple entries exist with the same local port, c_if(), with different
IPv4 addresses, c_ip(), there is either a non-CDP/LLDP device in between two
or more devices or multiple devices which are not directly connected.
Use the data from the Layer2 Topology Table below to dig deeper.
=item $enterasys->c_port()
Returns reference to hash. Key: iid Value: remote port (interfaces)
=item $enterasys->c_id()
Returns reference to hash. Key: iid Value: string value used to identify the
chassis component associated with the remote system.
=item $enterasys->c_platform()
Returns reference to hash. Key: iid Value: Remote Device Type
=back
=head2 Table Methods imported from SNMP::Info::MAU
See documentation in L<SNMP::Info::MAU/"TABLE METHODS"> for details.
=head2 Table Methods imported from SNMP::Info::LLDP
See documentation in L<SNMP::Info::LLDP/"TABLE METHODS"> for details.
=head2 Table Methods imported from SNMP::Info::CDP
See documentation in L<SNMP::Info::CDP/"TABLE METHODS"> for details.
=head2 Table Methods imported from SNMP::Info::Layer3
See documentation in L<SNMP::Info::Layer3/"TABLE METHODS"> for details.
=cut
|