1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318
|
# SNMP::Info::Layer3::N1600 - SNMP Interface to Nortel N16XX devices
# $Id$
#
# Copyright (c) 2008 Eric Miller
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions are met:
#
# * Redistributions of source code must retain the above copyright notice,
# this list of conditions and the following disclaimer.
# * Redistributions in binary form must reproduce the above copyright
# notice, this list of conditions and the following disclaimer in the
# documentation and/or other materials provided with the distribution.
# * Neither the name of the University of California, Santa Cruz nor the
# names of its contributors may be used to endorse or promote products
# derived from this software without specific prior written permission.
#
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
# LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
# POSSIBILITY OF SUCH DAMAGE.
package SNMP::Info::Layer3::N1600;
use strict;
use Exporter;
use SNMP::Info::Layer3;
use SNMP::Info::SONMP;
@SNMP::Info::Layer3::N1600::ISA
= qw/SNMP::Info::Layer3 SNMP::Info::SONMP Exporter/;
@SNMP::Info::Layer3::N1600::EXPORT_OK = qw//;
use vars qw/$VERSION %GLOBALS %FUNCS %MIBS %MUNGE/;
$VERSION = '2.06';
%MIBS = (
%SNMP::Info::Layer3::MIBS,
%SNMP::Info::SONMP::MIBS,
'SWL2MGMT-MIB' => 'swL2MgmtMIB',
'RAPID-CITY' => 'rapidCity',
);
%GLOBALS = ( %SNMP::Info::Layer3::GLOBALS, %SNMP::Info::SONMP::GLOBALS, );
%FUNCS = (
%SNMP::Info::Layer3::FUNCS,
%SNMP::Info::SONMP::FUNCS,
# SWL2MGMT-MIB
# swL2PortInfoTable
'n1600_nway_status' => 'swL2PortInfoNwayStatus',
# swL2PortCtrlTable
'n1600_nway_state' => 'swL2PortCtrlNwayState',
);
%MUNGE = (
# Inherit all the built in munging
%SNMP::Info::Layer3::MUNGE,
%SNMP::Info::SONMP::MUNGE,
);
# Method OverRides
sub model {
my $n1600 = shift;
my $id = $n1600->id();
unless ( defined $id ) {
print
" SNMP::Info::Layer3::N1600::model() - Device does not support sysObjectID\n"
if $n1600->debug();
return;
}
my $model = &SNMP::translateObj($id);
return $id unless defined $model;
$model =~ s/^rcA//i;
return $model;
}
sub vendor {
return 'nortel';
}
sub os {
return 'passport';
}
sub os_ver {
my $n1600 = shift;
my $descr = $n1600->description();
return unless defined $descr;
if ( $descr =~ m/(\d+\.\d+\.\d+\.\d+)/ ) {
return $1;
}
return;
}
sub interfaces {
my $n1600 = shift;
my $partial = shift;
my $i_index = $n1600->i_index($partial) || {};
my %if;
foreach my $iid ( keys %$i_index ) {
my $index = $i_index->{$iid};
next unless defined $index;
my $slotport = "1.$index";
$if{$iid} = $slotport;
}
return \%if;
}
sub i_duplex {
my $n1600 = shift;
my $partial = shift;
my $nway_status = $n1600->n1600_nway_status($partial) || {};
my %i_duplex;
foreach my $iid ( keys %$nway_status ) {
my $duplex = $nway_status->{$iid};
next unless defined $duplex;
next if $duplex =~ /other/i;
$i_duplex{$iid} = 'half' if $duplex =~ /half/i;
$i_duplex{$iid} = 'full' if $duplex =~ /full/i;
}
return \%i_duplex;
}
sub i_duplex_admin {
my $n1600 = shift;
my $partial = shift;
my $nway_state = $n1600->n1600_nway_state($partial) || {};
my %i_duplex;
foreach my $iid ( keys %$nway_state ) {
my $duplex = $nway_state->{$iid};
next unless defined $duplex;
next if $duplex =~ /other/i;
$i_duplex{$iid} = 'half' if $duplex =~ /half/i;
$i_duplex{$iid} = 'full' if $duplex =~ /full/i;
$i_duplex{$iid} = 'auto' if $duplex =~ /nway-enabled/i;
}
return \%i_duplex;
}
# Required for SNMP::Info::SONMP
sub index_factor {
return 64;
}
1;
__END__
=head1 NAME
SNMP::Info::Layer3::N1600 - SNMP Interface to Nortel 16XX Network Devices
=head1 AUTHOR
Eric Miller
=head1 SYNOPSIS
# Let SNMP::Info determine the correct subclass for you.
my $n1600 = new SNMP::Info(
AutoSpecify => 1,
Debug => 1,
DestHost => 'myswitch',
Community => 'public',
Version => 1
)
or die "Can't connect to DestHost.\n";
my $class = $n1600->class();
print "SNMP::Info determined this device to fall under subclass : $class\n";
=head1 DESCRIPTION
Provides abstraction to the configuration information obtainable from a Nortel
N16XX device through SNMP.
For speed or debugging purposes you can call the subclass directly, but not
after determining a more specific class using the method above.
my $n1600 = new SNMP::Info::Layer3::N1600(...);
=head2 Inherited Classes
=over
=item SNMP::Info::Layer3
=item SNMP::Info::SONMP
=back
=head2 Required MIBs
=over
=item F<SWL2MGMT-MIB>
=item F<RAPID-CITY>
=item Inherited Classes' MIBs
See classes listed above for their required MIBs.
=back
=head1 GLOBALS
These are methods that return scalar value from SNMP
=over
=item $n1600->bulkwalk_no
Return C<1>. Bulkwalk is currently turned off for this class.
=item $n1600->model()
Returns model type. Checks $n1600->id() against the
F<RAPID-CITY-MIB> and then parses out C<rcA>.
=item $n1600->vendor()
Returns 'nortel'
=item $n1600->os()
Returns 'passport'
=item $n1600->os_ver()
Returns os version extracted from C<sysDescr>.
=back
=head2 Overrides
=over
=item $n1600->index_factor()
Required by SNMP::Info::SONMP. Number representing the number of ports
reserved per slot within the device MIB.
Returns 64 since largest switch has 48 ports. Since these switches can
not stack, the only requirement to reserve more than the max number of ports.
=back
=head2 Globals imported from SNMP::Info::Layer3
See documentation in L<SNMP::Info::Layer3/"GLOBALS"> for details.
=head2 Globals imported from SNMP::Info::SONMP
See documentation in SNMP::SONMP::Layer3 for details.
=head1 TABLE METHODS
These are methods that return tables of information in the form of a reference
to a hash.
=head2 Overrides
=over
=item $n1600->interfaces()
Returns reference to hash of interface names to iids.
Places a 1 in front of index number. This is required for compatibility with
SNMP::Info::SONMP.
=item $n1600->i_duplex()
Returns reference to hash of interface operational link duplex status.
=item $n1600->i_duplex_admin()
Returns reference to hash of interface administrative link duplex status.
=back
=head2 Table Methods imported from SNMP::Info::Layer3
See documentation in L<SNMP::Info::Layer3/"TABLE METHODS"> for details.
=head2 Table Methods imported from SNMP::Info::SONMP
See documentation in L<SNMP::Info::SONMP/"TABLE METHODS"> for details.
=cut
|