1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086
|
-- extracted from rfc1493.txt
BRIDGE-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter, TimeTicks
FROM RFC1155-SMI
mib-2
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215;
-- All representations of MAC addresses in this MIB Module
-- use, as a textual convention (i.e. this convention does
-- not affect their encoding), the data type:
MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet address
-- in the
-- "canonical"
-- order
-- defined by IEEE 802.1a, i.e., as if it were transmitted
-- least significant bit first, even though 802.5 (in
-- contrast to other n802.x protocols) requires MAC
-- addresses to be transmitted most significant bit first.
--
-- 16-bit addresses, if needed, are represented by setting
-- their upper 4 octets to all 0's, i.e., AAFF would be
-- represented as 00000000AAFF.
-- Similarly, all representations of Bridge-Id in this MIB
-- Module use, as a textual convention (i.e. this
-- convention does not affect their encoding), the data
-- type:
BridgeId ::= OCTET STRING (SIZE (8)) -- the
-- Bridge-Identifier
-- as used in the
-- Spanning Tree
-- Protocol to uniquely identify a bridge. Its first two
-- octets (in network byte order) contain a priority
-- value and its last 6 octets contain the MAC address
-- used to refer to a bridge in a unique fashion
-- (typically, the numerically smallest MAC address
-- of all ports on the bridge).
-- Several objects in this MIB module represent values of
-- timers used by the Spanning Tree Protocol. In this
-- MIB, these timers have values in units of hundreths of
-- a second (i.e. 1/100 secs).
-- These timers, when stored in a Spanning Tree Protocol's
-- BPDU, are in units of 1/256 seconds. Note, however,
-- that 802.1D-1990 specifies a settable granularity of
-- no more than 1 second for these timers. To avoid
-- ambiguity, a data type is defined here as a textual
-- convention and all representation of these timers
-- in this MIB module are defined using this data type. An
-- algorithm is also defined for converting between the
-- different units, to ensure a timer's value is not
-- distorted by multiple conversions.
-- The data type is:
Timeout ::= INTEGER -- a STP timer in units of 1/100 seconds
-- To convert a Timeout value into a value in units of
-- 1/256 seconds, the following algorithm should be used:
--
-- b = floor( (n * 256) / 100)
--
-- where:
-- floor = quotient [ignore remainder]
-- n is the value in 1/100 second units
-- b is the value in 1/256 second units
--
-- To convert the value from 1/256 second units back to
-- 1/100 seconds, the following algorithm should be used:
--
-- n = ceiling( (b * 100) / 256)
--
-- where:
-- ceiling = quotient [if remainder is 0], or
-- quotient + 1 [if remainder is non-zero]
-- n is the value in 1/100 second units
-- b is the value in 1/256 second units
--
-- Note: it is important that the arithmetic operations are
-- done in the order specified (i.e., multiply first, divide
-- second).
dot1dBridge OBJECT IDENTIFIER ::= { mib-2 17 }
-- groups in the Bridge MIB
dot1dBase OBJECT IDENTIFIER ::= { dot1dBridge 1 }
dot1dStp OBJECT IDENTIFIER ::= { dot1dBridge 2 }
dot1dSr OBJECT IDENTIFIER ::= { dot1dBridge 3 }
-- separately documented
dot1dTp OBJECT IDENTIFIER ::= { dot1dBridge 4 }
dot1dStatic OBJECT IDENTIFIER ::= { dot1dBridge 5 }
-- the dot1dBase group
-- Implementation of the dot1dBase group is mandatory for all
-- bridges.
dot1dBaseBridgeAddress OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address used by this bridge when it must
be referred to in a unique fashion. It is
recommended that this be the numerically smallest
MAC address of all ports that belong to this
bridge. However it is only required to be unique.
When concatenated with dot1dStpPriority a unique
BridgeIdentifier is formed which is used in the
Spanning Tree Protocol."
REFERENCE
"IEEE 802.1D-1990: Sections 6.4.1.1.3 and 3.12.5"
::= { dot1dBase 1 }
dot1dBaseNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports controlled by this bridging
entity."
REFERENCE
"IEEE 802.1D-1990: Section 6.4.1.1.3"
::= { dot1dBase 2 }
dot1dBaseType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
transparent-only(2),
sourceroute-only(3),
srt(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates what type of bridging this bridge can
perform. If a bridge is actually performing a
certain type of bridging this will be indicated by
entries in the port table for the given type."
::= { dot1dBase 3 }
-- The Generic Bridge Port Table
dot1dBasePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dBasePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains generic information about
every port that is associated with this bridge.
Transparent, source-route, and srt ports are
included."
::= { dot1dBase 4 }
dot1dBasePortEntry OBJECT-TYPE
SYNTAX Dot1dBasePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information for each port of the
bridge."
REFERENCE
"IEEE 802.1D-1990: Section 6.4.2, 6.6.1"
INDEX { dot1dBasePort }
::= { dot1dBasePortTable 1 }
Dot1dBasePortEntry ::=
SEQUENCE {
dot1dBasePort
INTEGER,
dot1dBasePortIfIndex
INTEGER,
dot1dBasePortCircuit
OBJECT IDENTIFIER,
dot1dBasePortDelayExceededDiscards
Counter,
dot1dBasePortMtuExceededDiscards
Counter
}
dot1dBasePort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the port for which this entry
contains bridge management information."
::= { dot1dBasePortEntry 1 }
dot1dBasePortIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the instance of the ifIndex object,
defined in MIB-II, for the interface corresponding
to this port."
::= { dot1dBasePortEntry 2 }
dot1dBasePortCircuit OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"For a port which (potentially) has the same value
of dot1dBasePortIfIndex as another port on the
same bridge, this object contains the name of an
object instance unique to this port. For example,
in the case where multiple ports correspond one-
to-one with multiple X.25 virtual circuits, this
value might identify an (e.g., the first) object
instance associated with the X.25 virtual circuit
corresponding to this port.
For a port which has a unique value of
dot1dBasePortIfIndex, this object can have the
value { 0 0 }."
::= { dot1dBasePortEntry 3 }
dot1dBasePortDelayExceededDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames discarded by this port due
to excessive transit delay through the bridge. It
is incremented by both transparent and source
route bridges."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { dot1dBasePortEntry 4 }
dot1dBasePortMtuExceededDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames discarded by this port due
to an excessive size. It is incremented by both
transparent and source route bridges."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { dot1dBasePortEntry 5 }
-- the dot1dStp group
-- Implementation of the dot1dStp group is optional. It is
-- implemented by those bridges that support the Spanning Tree
-- Protocol.
dot1dStpProtocolSpecification OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
decLb100(2),
ieee8021d(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An indication of what version of the Spanning
Tree Protocol is being run. The value
'decLb100(2)' indicates the DEC LANbridge 100
Spanning Tree protocol. IEEE 802.1d
implementations will return 'ieee8021d(3)'. If
future versions of the IEEE Spanning Tree Protocol
are released that are incompatible with the
current version a new value will be defined."
::= { dot1dStp 1 }
dot1dStpPriority OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of the write-able portion of the Bridge
ID, i.e., the first two octets of the (8 octet
long) Bridge ID. The other (last) 6 octets of the
Bridge ID are given by the value of
dot1dBaseBridgeAddress."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.7"
::= { dot1dStp 2 }
dot1dStpTimeSinceTopologyChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time (in hundredths of a second) since the
last time a topology change was detected by the
bridge entity."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.1.1.3"
::= { dot1dStp 3 }
dot1dStpTopChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of topology changes detected by
this bridge since the management entity was last
reset or initialized."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.1.1.3"
::= { dot1dStp 4 }
dot1dStpDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bridge identifier of the root of the spanning
tree as determined by the Spanning Tree Protocol
as executed by this node. This value is used as
the Root Identifier parameter in all Configuration
Bridge PDUs originated by this node."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.1"
::= { dot1dStp 5 }
dot1dStpRootCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The cost of the path to the root as seen from
this bridge."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.2"
::= { dot1dStp 6 }
dot1dStpRootPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the port which offers the
lowest cost path from this bridge to the root
bridge."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.3"
::= { dot1dStp 7 }
dot1dStpMaxAge OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum age of Spanning Tree Protocol
information learned from the network on any port
before it is discarded, in units of hundredths of
a second. This is the actual value that this
bridge is currently using."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.4"
::= { dot1dStp 8 }
dot1dStpHelloTime OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of time between the transmission of
Configuration bridge PDUs by this node on any port
when it is the root of the spanning tree or trying
to become so, in units of hundredths of a second.
This is the actual value that this bridge is
currently using."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.5"
::= { dot1dStp 9 }
dot1dStpHoldTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This time value determines the interval length
during which no more than two Configuration bridge
PDUs shall be transmitted by this node, in units
of hundredths of a second."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.14"
::= { dot1dStp 10 }
dot1dStpForwardDelay OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This time value, measured in units of hundredths
of a second, controls how fast a port changes its
spanning state when moving towards the Forwarding
state. The value determines how long the port
stays in each of the Listening and Learning
states, which precede the Forwarding state. This
value is also used, when a topology change has
been detected and is underway, to age all dynamic
entries in the Forwarding Database. [Note that
this value is the one that this bridge is
currently using, in contrast to
dot1dStpBridgeForwardDelay which is the value that
this bridge and all others would start using
if/when this bridge were to become the root.]"
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.6"
::= { dot1dStp 11 }
dot1dStpBridgeMaxAge OBJECT-TYPE
SYNTAX Timeout (600..4000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value that all bridges use for MaxAge when
this bridge is acting as the root. Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
dot1dStpBridgeHelloTime. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.8"
::= { dot1dStp 12 }
dot1dStpBridgeHelloTime OBJECT-TYPE
SYNTAX Timeout (100..1000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value that all bridges use for HelloTime when
this bridge is acting as the root. The
granularity of this timer is specified by 802.1D-
1990 to be 1 second. An agent may return a
badValue error if a set is attempted to a value
which is not a whole number of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.9"
::= { dot1dStp 13 }
dot1dStpBridgeForwardDelay OBJECT-TYPE
SYNTAX Timeout (400..3000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value that all bridges use for ForwardDelay
when this bridge is acting as the root. Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
dot1dStpBridgeMaxAge. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.10"
::= { dot1dStp 14 }
-- The Spanning Tree Port Table
dot1dStpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dStpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains port-specific information
for the Spanning Tree Protocol."
::= { dot1dStp 15 }
dot1dStpPortEntry OBJECT-TYPE
SYNTAX Dot1dStpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information maintained by every port
about the Spanning Tree Protocol state for that
port."
INDEX { dot1dStpPort }
::= { dot1dStpPortTable 1 }
Dot1dStpPortEntry ::=
SEQUENCE {
dot1dStpPort
INTEGER,
dot1dStpPortPriority
INTEGER,
dot1dStpPortState
INTEGER,
dot1dStpPortEnable
INTEGER,
dot1dStpPortPathCost
INTEGER,
dot1dStpPortDesignatedRoot
BridgeId,
dot1dStpPortDesignatedCost
INTEGER,
dot1dStpPortDesignatedBridge
BridgeId,
dot1dStpPortDesignatedPort
OCTET STRING,
dot1dStpPortForwardTransitions
Counter
}
dot1dStpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the port for which this entry
contains Spanning Tree Protocol management
information."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.2.1.2"
::= { dot1dStpPortEntry 1 }
dot1dStpPortPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of the priority field which is
contained in the first (in network byte order)
octet of the (2 octet long) Port ID. The other
octet of the Port ID is given by the value of
dot1dStpPort."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.1"
::= { dot1dStpPortEntry 2 }
dot1dStpPortState OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
blocking(2),
listening(3),
learning(4),
forwarding(5),
broken(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port's current state as defined by
application of the Spanning Tree Protocol. This
state controls what action a port takes on
reception of a frame. If the bridge has detected
a port that is malfunctioning it will place that
port into the broken(6) state. For ports which
are disabled (see dot1dStpPortEnable), this object
will have a value of disabled(1)."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.2"
::= { dot1dStpPortEntry 3 }
dot1dStpPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The enabled/disabled status of the port."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.2"
::= { dot1dStpPortEntry 4 }
dot1dStpPortPathCost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The contribution of this port to the path cost of
paths towards the spanning tree root which include
this port. 802.1D-1990 recommends that the
default value of this parameter be in inverse
proportion to the speed of the attached LAN."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.3"
::= { dot1dStpPortEntry 5 }
dot1dStpPortDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique Bridge Identifier of the Bridge
recorded as the Root in the Configuration BPDUs
transmitted by the Designated Bridge for the
segment to which the port is attached."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.4"
::= { dot1dStpPortEntry 6 }
dot1dStpPortDesignatedCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The path cost of the Designated Port of the
segment connected to this port. This value is
compared to the Root Path Cost field in received
bridge PDUs."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.5"
::= { dot1dStpPortEntry 7 }
dot1dStpPortDesignatedBridge OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bridge Identifier of the bridge which this
port considers to be the Designated Bridge for
this port's segment."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.6"
::= { dot1dStpPortEntry 8 }
dot1dStpPortDesignatedPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Port Identifier of the port on the Designated
Bridge for this port's segment."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.7"
::= { dot1dStpPortEntry 9 }
dot1dStpPortForwardTransitions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times this port has transitioned
from the Learning state to the Forwarding state."
::= { dot1dStpPortEntry 10 }
-- the dot1dTp group
-- Implementation of the dot1dTp group is optional. It is
-- implemented by those bridges that support the transparent
-- bridging mode. A transparent or SRT bridge will implement
-- this group.
dot1dTpLearnedEntryDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of Forwarding Database entries,
which have been or would have been learnt, but
have been discarded due to a lack of space to
store them in the Forwarding Database. If this
counter is increasing, it indicates that the
Forwarding Database is regularly becoming full (a
condition which has unpleasant performance effects
on the subnetwork). If this counter has a
significant value but is not presently increasing,
it indicates that the problem has been occurring
but is not persistent."
REFERENCE
"IEEE 802.1D-1990: Section 6.7.1.1.3"
::= { dot1dTp 1 }
dot1dTpAgingTime OBJECT-TYPE
SYNTAX INTEGER (10..1000000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The timeout period in seconds for aging out
dynamically learned forwarding information.
802.1D-1990 recommends a default of 300 seconds."
REFERENCE
"IEEE 802.1D-1990: Section 6.7.1.1.3"
::= { dot1dTp 2 }
-- The Forwarding Database for Transparent Bridges
dot1dTpFdbTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dTpFdbEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains information about unicast
entries for which the bridge has forwarding and/or
filtering information. This information is used
by the transparent bridging function in
determining how to propagate a received frame."
::= { dot1dTp 3 }
dot1dTpFdbEntry OBJECT-TYPE
SYNTAX Dot1dTpFdbEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a specific unicast MAC address
for which the bridge has some forwarding and/or
filtering information."
INDEX { dot1dTpFdbAddress }
::= { dot1dTpFdbTable 1 }
Dot1dTpFdbEntry ::=
SEQUENCE {
dot1dTpFdbAddress
MacAddress,
dot1dTpFdbPort
INTEGER,
dot1dTpFdbStatus
INTEGER
}
dot1dTpFdbAddress OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unicast MAC address for which the bridge has
forwarding and/or filtering information."
REFERENCE
"IEEE 802.1D-1990: Section 3.9.1, 3.9.2"
::= { dot1dTpFdbEntry 1 }
dot1dTpFdbPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Either the value '0', or the port number of the
port on which a frame having a source address
equal to the value of the corresponding instance
of dot1dTpFdbAddress has been seen. A value of
'0' indicates that the port number has not been
learned but that the bridge does have some
forwarding/filtering information about this
address (e.g. in the dot1dStaticTable).
Implementors are encouraged to assign the port
value to this object whenever it is learned even
for addresses for which the corresponding value of
dot1dTpFdbStatus is not learned(3)."
::= { dot1dTpFdbEntry 2 }
dot1dTpFdbStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
learned(3),
self(4),
mgmt(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of this entry. The meanings of the
values are:
other(1) : none of the following. This would
include the case where some other
MIB object (not the corresponding
instance of dot1dTpFdbPort, nor an
entry in the dot1dStaticTable) is
being used to determine if and how
frames addressed to the value of
the corresponding instance of
dot1dTpFdbAddress are being
forwarded.
invalid(2) : this entry is not longer valid
(e.g., it was learned but has since
aged-out), but has not yet been
flushed from the table.
learned(3) : the value of the corresponding
instance of dot1dTpFdbPort was
learned, and is being used.
self(4) : the value of the corresponding
instance of dot1dTpFdbAddress
represents one of the bridge's
addresses. The corresponding
instance of dot1dTpFdbPort
indicates which of the bridge's
ports has this address.
mgmt(5) : the value of the corresponding
instance of dot1dTpFdbAddress is
also the value of an existing
instance of dot1dStaticAddress."
::= { dot1dTpFdbEntry 3 }
-- Port Table for Transparent Bridges
dot1dTpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dTpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains information about every
port that is associated with this transparent
bridge."
::= { dot1dTp 4 }
dot1dTpPortEntry OBJECT-TYPE
SYNTAX Dot1dTpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information for each port of a
transparent bridge."
INDEX { dot1dTpPort }
::= { dot1dTpPortTable 1 }
Dot1dTpPortEntry ::=
SEQUENCE {
dot1dTpPort
INTEGER,
dot1dTpPortMaxInfo
INTEGER,
dot1dTpPortInFrames
Counter,
dot1dTpPortOutFrames
Counter,
dot1dTpPortInDiscards
Counter
}
dot1dTpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the port for which this entry
contains Transparent bridging management
information."
::= { dot1dTpPortEntry 1 }
-- It would be nice if we could use ifMtu as the size of the
-- largest INFO field, but we can't because ifMtu is defined
-- to be the size that the (inter-)network layer can use which
-- can differ from the MAC layer (especially if several layers
-- of encapsulation are used).
dot1dTpPortMaxInfo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum size of the INFO (non-MAC) field that
this port will receive or transmit."
::= { dot1dTpPortEntry 2 }
dot1dTpPortInFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that have been received by
this port from its segment. Note that a frame
received on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function, including bridge management
frames."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { dot1dTpPortEntry 3 }
dot1dTpPortOutFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that have been transmitted
by this port to its segment. Note that a frame
transmitted on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function, including bridge management
frames."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { dot1dTpPortEntry 4 }
dot1dTpPortInDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of valid frames received which were
discarded (i.e., filtered) by the Forwarding
Process."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { dot1dTpPortEntry 5 }
-- The Static (Destination-Address Filtering) Database
-- Implementation of this group is optional.
dot1dStaticTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing filtering information
configured into the bridge by (local or network)
management specifying the set of ports to which
frames received from specific ports and containing
specific destination addresses are allowed to be
forwarded. The value of zero in this table as the
port number from which frames with a specific
destination address are received, is used to
specify all ports for which there is no specific
entry in this table for that particular
destination address. Entries are valid for
unicast and for group/broadcast addresses."
REFERENCE
"IEEE 802.1D-1990: Section 6.7.2"
::= { dot1dStatic 1 }
dot1dStaticEntry OBJECT-TYPE
SYNTAX Dot1dStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Filtering information configured into the bridge
by (local or network) management specifying the
set of ports to which frames received from a
specific port and containing a specific
destination address are allowed to be forwarded."
REFERENCE
"IEEE 802.1D-1990: Section 6.7.2"
INDEX { dot1dStaticAddress, dot1dStaticReceivePort }
::= { dot1dStaticTable 1 }
Dot1dStaticEntry ::=
SEQUENCE {
dot1dStaticAddress
MacAddress,
dot1dStaticReceivePort
INTEGER,
dot1dStaticAllowedToGoTo
OCTET STRING,
dot1dStaticStatus
INTEGER
}
dot1dStaticAddress OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The destination MAC address in a frame to which
this entry's filtering information applies. This
object can take the value of a unicast address, a
group address or the broadcast address."
REFERENCE
"IEEE 802.1D-1990: Section 3.9.1, 3.9.2"
::= { dot1dStaticEntry 1 }
dot1dStaticReceivePort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Either the value '0', or the port number of the
port from which a frame must be received in order
for this entry's filtering information to apply.
A value of zero indicates that this entry applies
on all ports of the bridge for which there is no
other applicable entry."
::= { dot1dStaticEntry 2 }
dot1dStaticAllowedToGoTo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The set of ports to which frames received from a
specific port and destined for a specific MAC
address, are allowed to be forwarded. Each octet
within the value of this object specifies a set of
eight ports, with the first octet specifying ports
1 through 8, the second octet specifying ports 9
through 16, etc. Within each octet, the most
significant bit represents the lowest numbered
port, and the least significant bit represents the
highest numbered port. Thus, each port of the
bridge is represented by a single bit within the
value of this object. If that bit has a value of
'1' then that port is included in the set of
ports; the port is not included if its bit has a
value of '0'. (Note that the setting of the bit
corresponding to the port from which a frame is
received is irrelevant.) The default value of
this object is a string of ones of appropriate
length."
::= { dot1dStaticEntry 3 }
dot1dStaticStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
permanent(3),
deleteOnReset(4),
deleteOnTimeout(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the status of this entry.
The default value is permanent(3).
other(1) - this entry is currently in use but
the conditions under which it will
remain so are different from each of the
following values.
invalid(2) - writing this value to the object
removes the corresponding entry.
permanent(3) - this entry is currently in use
and will remain so after the next reset
of the bridge.
deleteOnReset(4) - this entry is currently in
use and will remain so until the next
reset of the bridge.
deleteOnTimeout(5) - this entry is currently
in use and will remain so until it is
aged out."
::= { dot1dStaticEntry 4 }
-- Traps for use by Bridges
-- Traps for the Spanning Tree Protocol
newRoot TRAP-TYPE
ENTERPRISE dot1dBridge
DESCRIPTION
"The newRoot trap indicates that the sending agent
has become the new root of the Spanning Tree; the
trap is sent by a bridge soon after its election
as the new root, e.g., upon expiration of the
Topology Change Timer immediately subsequent to
its election. Implementation of this trap is
optional."
::= 1
topologyChange TRAP-TYPE
ENTERPRISE dot1dBridge
DESCRIPTION
"A topologyChange trap is sent by a bridge when
any of its configured ports transitions from the
Learning state to the Forwarding state, or from
the Forwarding state to the Blocking state. The
trap is not sent if a newRoot trap is sent for the
same transition. Implementation of this trap is
optional."
::= 2