1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2876 2877 2878 2879 2880 2881 2882 2883 2884 2885 2886 2887 2888 2889 2890 2891 2892 2893 2894 2895 2896 2897 2898 2899 2900 2901 2902 2903 2904 2905 2906 2907 2908 2909 2910 2911 2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923 2924 2925 2926 2927 2928 2929 2930 2931 2932 2933 2934 2935 2936 2937 2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981 2982 2983 2984 2985 2986 2987 2988 2989 2990 2991 2992 2993 2994 2995 2996 2997 2998 2999 3000 3001 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3013 3014 3015 3016 3017 3018 3019 3020 3021 3022 3023 3024 3025 3026 3027 3028 3029 3030 3031 3032 3033 3034 3035 3036 3037 3038 3039 3040 3041 3042 3043 3044 3045 3046 3047 3048 3049 3050 3051 3052 3053 3054 3055 3056 3057 3058 3059 3060 3061 3062 3063 3064 3065 3066 3067 3068 3069 3070 3071 3072 3073 3074 3075 3076 3077 3078 3079 3080 3081 3082 3083 3084 3085 3086 3087 3088 3089 3090 3091 3092 3093 3094 3095 3096 3097 3098 3099 3100 3101 3102 3103 3104 3105 3106 3107 3108 3109 3110 3111 3112 3113 3114 3115 3116 3117 3118 3119 3120 3121 3122 3123 3124 3125 3126 3127 3128 3129 3130 3131 3132 3133 3134 3135 3136 3137 3138 3139 3140 3141 3142 3143 3144 3145 3146 3147 3148 3149 3150 3151 3152 3153 3154 3155 3156 3157 3158 3159 3160 3161 3162 3163 3164 3165 3166 3167 3168 3169 3170 3171 3172 3173 3174 3175 3176 3177 3178 3179 3180 3181 3182 3183 3184 3185 3186 3187 3188 3189 3190 3191 3192 3193 3194 3195 3196 3197 3198 3199 3200 3201 3202 3203 3204 3205 3206 3207 3208 3209 3210 3211 3212 3213 3214 3215 3216 3217 3218 3219 3220 3221 3222 3223 3224 3225 3226 3227 3228 3229 3230 3231 3232 3233 3234 3235 3236 3237 3238 3239 3240 3241 3242 3243 3244 3245 3246 3247 3248 3249 3250 3251 3252 3253 3254 3255 3256 3257 3258 3259 3260 3261 3262 3263 3264 3265 3266 3267 3268 3269 3270 3271 3272 3273 3274 3275 3276 3277 3278 3279 3280 3281 3282 3283 3284 3285 3286 3287 3288 3289 3290 3291 3292 3293 3294 3295 3296 3297 3298 3299 3300 3301 3302 3303 3304 3305 3306 3307 3308 3309 3310 3311 3312 3313 3314 3315 3316 3317 3318 3319 3320 3321 3322 3323 3324 3325 3326 3327 3328 3329 3330 3331 3332 3333 3334 3335 3336 3337 3338 3339 3340 3341 3342 3343 3344 3345 3346 3347 3348 3349 3350 3351 3352 3353 3354 3355 3356 3357 3358 3359 3360 3361 3362 3363 3364 3365 3366 3367 3368 3369 3370 3371 3372 3373 3374 3375 3376 3377 3378 3379 3380 3381 3382 3383 3384 3385 3386 3387 3388 3389 3390 3391 3392 3393 3394 3395 3396 3397 3398 3399 3400 3401 3402 3403 3404 3405 3406 3407 3408 3409 3410 3411 3412 3413 3414 3415 3416 3417 3418 3419 3420 3421 3422 3423 3424 3425 3426 3427 3428 3429 3430 3431 3432 3433 3434 3435 3436 3437 3438 3439 3440 3441 3442 3443 3444 3445 3446 3447 3448 3449 3450 3451 3452 3453 3454 3455 3456 3457 3458 3459 3460 3461 3462 3463 3464 3465 3466 3467 3468 3469 3470 3471 3472 3473 3474 3475 3476 3477 3478 3479 3480 3481 3482 3483 3484 3485 3486 3487 3488 3489 3490 3491 3492 3493 3494 3495 3496 3497 3498 3499 3500 3501 3502 3503 3504 3505 3506 3507 3508 3509 3510 3511 3512 3513 3514 3515 3516 3517 3518 3519 3520 3521 3522 3523 3524 3525 3526 3527 3528 3529 3530 3531 3532 3533 3534 3535 3536 3537 3538 3539 3540 3541 3542 3543 3544 3545 3546 3547 3548 3549 3550 3551 3552 3553 3554 3555 3556 3557 3558 3559 3560 3561 3562 3563 3564 3565 3566 3567 3568 3569 3570 3571 3572 3573 3574 3575 3576 3577 3578 3579 3580 3581 3582 3583 3584 3585 3586 3587 3588 3589 3590 3591 3592 3593 3594 3595 3596 3597 3598 3599 3600 3601 3602 3603 3604 3605 3606 3607 3608 3609 3610 3611 3612 3613 3614 3615 3616 3617 3618 3619 3620 3621 3622 3623 3624 3625 3626 3627 3628 3629 3630 3631 3632 3633 3634 3635 3636 3637 3638 3639 3640 3641 3642 3643 3644 3645 3646 3647 3648 3649 3650 3651 3652 3653 3654 3655 3656 3657 3658 3659 3660 3661 3662 3663 3664 3665 3666 3667 3668 3669 3670 3671 3672 3673 3674 3675 3676 3677 3678 3679 3680 3681 3682 3683 3684 3685 3686 3687 3688 3689 3690 3691 3692 3693 3694 3695 3696 3697 3698 3699 3700 3701 3702 3703 3704 3705 3706 3707 3708 3709 3710 3711 3712 3713 3714 3715 3716 3717 3718 3719 3720 3721 3722 3723 3724 3725 3726 3727 3728 3729 3730 3731 3732 3733 3734 3735 3736 3737 3738 3739 3740 3741 3742 3743 3744 3745 3746 3747 3748 3749 3750 3751 3752 3753 3754 3755 3756 3757 3758 3759 3760 3761 3762 3763 3764 3765 3766 3767 3768 3769 3770 3771 3772 3773 3774 3775 3776 3777 3778 3779 3780 3781 3782 3783 3784 3785 3786 3787 3788 3789 3790 3791 3792 3793 3794 3795 3796 3797 3798 3799 3800 3801 3802 3803 3804 3805 3806 3807 3808 3809 3810 3811 3812 3813 3814 3815 3816 3817 3818 3819 3820 3821 3822 3823 3824 3825 3826 3827 3828 3829 3830 3831 3832 3833 3834 3835 3836 3837 3838 3839 3840 3841 3842 3843 3844 3845 3846 3847 3848 3849 3850 3851 3852 3853 3854 3855 3856 3857 3858 3859 3860 3861 3862 3863 3864 3865 3866 3867 3868 3869 3870 3871 3872 3873 3874 3875 3876 3877 3878 3879 3880 3881 3882 3883 3884 3885 3886 3887 3888 3889 3890 3891 3892 3893 3894 3895 3896 3897 3898 3899 3900 3901 3902 3903 3904 3905 3906 3907 3908 3909 3910 3911 3912 3913 3914 3915 3916 3917 3918 3919 3920 3921 3922 3923 3924 3925 3926 3927 3928 3929 3930 3931 3932 3933 3934 3935 3936 3937 3938 3939 3940 3941 3942 3943 3944 3945 3946 3947 3948 3949 3950 3951 3952 3953 3954 3955 3956 3957 3958 3959 3960 3961 3962 3963 3964 3965 3966 3967 3968 3969 3970 3971 3972 3973 3974 3975 3976 3977 3978 3979 3980 3981 3982 3983 3984 3985 3986 3987 3988 3989 3990 3991 3992 3993 3994 3995 3996 3997 3998 3999 4000 4001 4002 4003 4004 4005 4006 4007 4008 4009 4010 4011 4012 4013 4014 4015 4016 4017 4018 4019 4020 4021 4022 4023 4024 4025 4026 4027 4028 4029 4030 4031 4032 4033 4034 4035 4036 4037 4038 4039 4040 4041 4042 4043 4044 4045 4046 4047 4048 4049 4050 4051 4052 4053 4054 4055 4056 4057 4058 4059 4060 4061 4062 4063 4064 4065 4066 4067 4068 4069 4070 4071 4072 4073 4074 4075 4076 4077 4078 4079 4080 4081 4082 4083 4084 4085 4086 4087 4088 4089 4090 4091 4092 4093 4094 4095 4096 4097 4098 4099 4100 4101 4102 4103 4104 4105 4106 4107 4108 4109 4110 4111 4112 4113 4114 4115 4116 4117 4118 4119 4120 4121 4122 4123 4124 4125 4126 4127 4128 4129 4130 4131 4132 4133 4134 4135 4136 4137 4138 4139 4140 4141 4142 4143 4144 4145 4146 4147 4148 4149 4150 4151 4152 4153 4154 4155 4156 4157 4158 4159 4160 4161 4162 4163 4164 4165 4166 4167 4168 4169 4170 4171 4172 4173 4174 4175 4176 4177 4178 4179 4180 4181 4182 4183 4184 4185 4186 4187 4188 4189 4190 4191 4192 4193 4194 4195 4196 4197 4198 4199 4200 4201 4202 4203 4204 4205 4206 4207 4208 4209 4210 4211 4212 4213 4214 4215 4216 4217 4218 4219 4220 4221 4222 4223 4224 4225 4226 4227 4228 4229 4230 4231 4232 4233 4234 4235 4236 4237 4238 4239 4240 4241 4242 4243 4244 4245 4246 4247 4248 4249 4250 4251 4252 4253 4254 4255 4256 4257 4258 4259 4260 4261 4262 4263 4264 4265 4266 4267 4268 4269 4270 4271 4272 4273 4274 4275 4276 4277 4278 4279 4280 4281 4282 4283 4284 4285 4286 4287 4288 4289 4290 4291 4292 4293 4294 4295 4296 4297 4298 4299 4300 4301 4302 4303 4304 4305 4306 4307 4308 4309 4310 4311 4312 4313 4314 4315 4316 4317 4318 4319 4320 4321 4322 4323 4324 4325 4326 4327 4328 4329 4330 4331 4332 4333 4334 4335 4336 4337 4338 4339 4340 4341 4342 4343 4344 4345 4346 4347 4348 4349 4350 4351 4352 4353 4354 4355 4356 4357 4358 4359 4360 4361 4362 4363 4364 4365 4366 4367 4368 4369 4370 4371 4372 4373 4374 4375 4376 4377 4378 4379 4380 4381 4382 4383 4384 4385 4386 4387 4388 4389 4390 4391 4392 4393 4394 4395 4396 4397 4398 4399 4400 4401 4402 4403 4404 4405 4406 4407 4408 4409 4410 4411 4412 4413 4414 4415 4416 4417 4418 4419 4420 4421 4422 4423 4424 4425 4426 4427 4428 4429 4430 4431 4432 4433 4434 4435 4436 4437 4438 4439 4440 4441 4442 4443 4444 4445 4446 4447 4448 4449 4450 4451 4452 4453 4454 4455 4456 4457 4458 4459 4460 4461 4462 4463 4464 4465 4466 4467 4468 4469 4470 4471 4472 4473 4474 4475 4476 4477 4478 4479 4480 4481 4482 4483 4484 4485 4486 4487 4488 4489 4490 4491 4492 4493 4494 4495 4496 4497 4498 4499 4500 4501 4502 4503 4504 4505 4506 4507 4508 4509 4510 4511 4512 4513 4514 4515 4516 4517 4518 4519 4520 4521 4522 4523 4524 4525 4526 4527 4528 4529 4530 4531 4532 4533 4534 4535 4536 4537 4538 4539 4540 4541 4542 4543 4544 4545 4546 4547 4548 4549 4550 4551 4552 4553 4554 4555 4556 4557 4558 4559 4560 4561 4562 4563 4564 4565 4566 4567 4568 4569 4570 4571 4572 4573 4574 4575 4576 4577 4578 4579 4580 4581 4582 4583 4584 4585 4586 4587 4588 4589 4590 4591 4592 4593 4594 4595 4596 4597 4598 4599 4600 4601 4602 4603 4604 4605 4606 4607 4608 4609 4610 4611 4612 4613 4614 4615 4616 4617 4618 4619 4620 4621 4622 4623 4624 4625 4626 4627 4628 4629 4630 4631 4632 4633 4634 4635 4636 4637 4638 4639 4640 4641 4642 4643 4644 4645 4646 4647 4648 4649 4650 4651 4652 4653 4654 4655 4656 4657 4658 4659 4660 4661 4662 4663 4664 4665 4666 4667 4668 4669 4670 4671 4672 4673 4674 4675 4676 4677 4678 4679 4680 4681 4682 4683 4684 4685 4686 4687 4688 4689 4690 4691 4692 4693 4694 4695 4696 4697 4698 4699 4700 4701 4702 4703 4704 4705 4706 4707 4708 4709 4710 4711 4712 4713 4714 4715 4716 4717 4718 4719 4720 4721 4722 4723 4724 4725 4726 4727 4728 4729 4730 4731 4732 4733 4734 4735 4736 4737 4738 4739 4740 4741 4742 4743 4744 4745 4746 4747 4748 4749 4750 4751 4752 4753 4754 4755 4756 4757 4758 4759 4760 4761 4762 4763 4764 4765 4766 4767 4768 4769 4770 4771 4772 4773 4774 4775 4776 4777 4778 4779 4780 4781 4782 4783 4784 4785 4786 4787 4788 4789 4790 4791 4792 4793 4794 4795 4796 4797 4798 4799 4800 4801 4802 4803 4804 4805 4806 4807 4808 4809 4810 4811 4812 4813 4814 4815 4816 4817 4818 4819 4820 4821 4822 4823 4824 4825 4826 4827 4828 4829 4830 4831 4832 4833 4834 4835 4836 4837 4838 4839 4840 4841 4842 4843 4844 4845 4846 4847 4848 4849 4850 4851 4852 4853 4854 4855 4856 4857 4858 4859 4860 4861 4862 4863 4864 4865 4866 4867 4868 4869 4870 4871 4872 4873 4874 4875 4876 4877 4878 4879 4880 4881 4882 4883 4884 4885 4886 4887 4888 4889 4890 4891 4892 4893 4894 4895 4896 4897 4898 4899 4900 4901 4902 4903 4904 4905 4906 4907 4908 4909 4910 4911 4912 4913 4914 4915 4916 4917 4918 4919 4920 4921 4922 4923 4924 4925 4926 4927 4928 4929 4930 4931 4932 4933 4934 4935 4936 4937 4938 4939 4940 4941 4942 4943 4944 4945 4946 4947 4948 4949 4950 4951 4952 4953 4954 4955 4956 4957 4958 4959 4960 4961 4962 4963 4964 4965 4966 4967 4968 4969 4970 4971 4972 4973 4974 4975 4976 4977 4978 4979 4980 4981 4982 4983 4984 4985 4986 4987 4988 4989 4990 4991 4992 4993 4994 4995 4996 4997 4998 4999 5000 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 5011 5012 5013 5014 5015 5016 5017 5018 5019 5020 5021 5022 5023 5024 5025 5026 5027 5028 5029 5030 5031 5032 5033 5034 5035 5036 5037 5038 5039 5040 5041 5042 5043 5044 5045 5046 5047 5048 5049 5050 5051 5052 5053 5054 5055 5056 5057 5058 5059 5060 5061 5062 5063 5064 5065 5066 5067 5068 5069 5070 5071 5072 5073 5074 5075 5076 5077 5078 5079 5080 5081 5082 5083 5084 5085 5086 5087 5088 5089 5090 5091 5092 5093 5094 5095 5096 5097 5098 5099 5100 5101 5102 5103 5104 5105 5106 5107 5108 5109 5110 5111 5112 5113 5114 5115 5116 5117 5118 5119 5120 5121 5122 5123 5124 5125 5126 5127 5128 5129 5130 5131 5132 5133 5134 5135 5136 5137 5138 5139 5140 5141 5142 5143 5144 5145 5146 5147 5148 5149 5150 5151 5152 5153 5154 5155 5156 5157 5158 5159 5160 5161 5162 5163 5164 5165 5166 5167 5168 5169 5170 5171 5172 5173 5174 5175 5176 5177 5178 5179 5180 5181 5182 5183 5184 5185 5186 5187 5188 5189 5190 5191 5192 5193 5194 5195 5196 5197 5198 5199 5200 5201 5202 5203 5204 5205 5206 5207 5208 5209 5210 5211 5212 5213 5214 5215 5216 5217 5218 5219 5220 5221 5222 5223 5224 5225 5226 5227 5228 5229 5230 5231 5232 5233 5234 5235 5236 5237 5238 5239 5240 5241 5242 5243 5244 5245 5246 5247 5248 5249 5250 5251 5252 5253 5254 5255 5256 5257 5258 5259 5260 5261 5262 5263 5264 5265 5266 5267 5268 5269 5270 5271 5272 5273 5274 5275 5276 5277 5278 5279 5280 5281 5282 5283 5284 5285 5286 5287 5288 5289 5290 5291 5292 5293 5294 5295 5296 5297 5298 5299 5300 5301 5302 5303 5304 5305 5306 5307 5308 5309 5310 5311 5312 5313 5314 5315 5316 5317 5318 5319 5320 5321 5322 5323 5324 5325 5326 5327 5328 5329 5330 5331 5332 5333 5334 5335 5336 5337 5338 5339 5340 5341 5342 5343 5344 5345 5346 5347 5348 5349 5350 5351 5352 5353 5354 5355 5356 5357 5358 5359 5360 5361 5362 5363 5364 5365 5366 5367 5368 5369 5370 5371 5372 5373 5374 5375 5376 5377 5378 5379 5380 5381 5382 5383 5384 5385 5386 5387 5388 5389 5390 5391 5392 5393 5394 5395 5396 5397 5398 5399 5400 5401 5402 5403 5404 5405 5406 5407 5408 5409 5410 5411 5412 5413 5414 5415 5416 5417 5418 5419 5420 5421 5422 5423 5424 5425 5426 5427 5428 5429 5430 5431 5432 5433 5434 5435 5436 5437 5438 5439 5440 5441 5442 5443 5444 5445 5446 5447 5448 5449 5450 5451 5452 5453 5454 5455 5456 5457 5458 5459 5460 5461 5462 5463 5464 5465 5466 5467 5468 5469 5470 5471 5472 5473 5474 5475 5476 5477 5478 5479 5480 5481 5482 5483 5484 5485 5486 5487 5488 5489 5490 5491 5492 5493 5494 5495 5496 5497 5498 5499 5500 5501 5502 5503 5504 5505 5506 5507 5508 5509 5510 5511 5512 5513 5514 5515 5516 5517 5518 5519 5520 5521 5522 5523 5524 5525 5526 5527 5528 5529 5530 5531 5532 5533 5534 5535 5536 5537 5538 5539 5540 5541 5542 5543 5544 5545 5546 5547 5548 5549 5550 5551 5552 5553 5554 5555 5556 5557 5558 5559 5560 5561 5562 5563 5564 5565 5566 5567 5568 5569 5570 5571 5572 5573 5574 5575 5576 5577 5578 5579 5580 5581 5582 5583 5584 5585 5586 5587 5588 5589 5590 5591 5592 5593 5594 5595 5596 5597 5598 5599 5600 5601 5602 5603 5604 5605 5606 5607 5608 5609 5610 5611 5612 5613 5614 5615 5616 5617 5618 5619 5620 5621 5622 5623 5624 5625 5626 5627 5628 5629 5630 5631 5632 5633 5634 5635 5636 5637 5638 5639 5640 5641 5642 5643 5644 5645 5646 5647 5648 5649 5650 5651 5652 5653 5654 5655 5656 5657 5658 5659 5660 5661 5662 5663 5664 5665 5666 5667 5668 5669 5670 5671 5672 5673 5674 5675 5676 5677 5678 5679 5680 5681 5682 5683 5684 5685 5686 5687 5688 5689 5690 5691 5692 5693 5694 5695 5696 5697 5698 5699 5700 5701 5702 5703 5704 5705 5706 5707 5708 5709 5710 5711 5712 5713 5714 5715 5716 5717 5718 5719 5720 5721 5722 5723 5724 5725 5726 5727 5728 5729 5730 5731 5732 5733 5734 5735 5736 5737 5738 5739 5740 5741 5742 5743 5744 5745 5746 5747 5748 5749 5750 5751 5752 5753 5754 5755 5756 5757 5758 5759 5760 5761 5762 5763 5764 5765 5766 5767 5768 5769 5770 5771 5772 5773 5774 5775 5776 5777 5778 5779 5780 5781 5782 5783 5784 5785 5786 5787 5788 5789 5790 5791 5792 5793 5794 5795 5796 5797 5798 5799 5800 5801 5802 5803 5804 5805 5806 5807 5808 5809 5810 5811 5812 5813 5814 5815 5816 5817 5818 5819 5820 5821 5822 5823 5824 5825 5826 5827 5828 5829 5830 5831 5832 5833 5834 5835 5836 5837 5838 5839 5840 5841 5842 5843 5844 5845 5846 5847 5848 5849 5850 5851 5852 5853 5854 5855 5856 5857 5858 5859 5860 5861 5862 5863 5864 5865 5866 5867 5868 5869 5870 5871 5872 5873 5874 5875 5876 5877 5878 5879 5880 5881 5882 5883 5884 5885 5886 5887 5888 5889 5890 5891 5892 5893 5894 5895 5896 5897 5898 5899 5900 5901 5902 5903 5904 5905 5906 5907 5908 5909 5910 5911 5912 5913 5914 5915 5916 5917 5918 5919 5920 5921 5922 5923 5924 5925 5926 5927 5928 5929 5930 5931 5932 5933 5934 5935 5936 5937 5938 5939 5940 5941 5942 5943 5944 5945 5946 5947 5948 5949 5950 5951 5952 5953 5954 5955 5956 5957 5958 5959 5960 5961 5962 5963 5964 5965 5966 5967 5968 5969 5970 5971 5972 5973 5974 5975 5976 5977 5978 5979 5980 5981 5982 5983 5984 5985 5986 5987 5988 5989 5990 5991 5992 5993 5994 5995 5996 5997 5998 5999 6000 6001 6002 6003 6004 6005 6006 6007 6008 6009 6010 6011 6012 6013 6014 6015 6016 6017 6018 6019 6020 6021 6022 6023 6024 6025 6026 6027 6028 6029 6030 6031 6032 6033 6034 6035 6036 6037 6038 6039 6040 6041 6042 6043 6044 6045 6046 6047 6048 6049 6050 6051 6052 6053 6054 6055 6056 6057 6058 6059 6060 6061 6062 6063 6064 6065 6066 6067 6068 6069 6070 6071 6072 6073 6074 6075 6076 6077 6078 6079 6080 6081 6082 6083 6084 6085 6086 6087 6088 6089 6090 6091 6092 6093 6094 6095 6096 6097 6098 6099 6100 6101 6102 6103 6104 6105 6106 6107 6108 6109 6110 6111 6112 6113 6114 6115 6116 6117 6118 6119 6120 6121 6122 6123 6124 6125 6126 6127 6128 6129 6130 6131 6132 6133 6134 6135 6136 6137 6138 6139 6140 6141 6142 6143 6144 6145 6146 6147 6148 6149 6150 6151 6152 6153 6154 6155 6156 6157 6158 6159 6160 6161 6162 6163 6164 6165 6166 6167 6168 6169 6170 6171 6172 6173 6174 6175 6176 6177 6178 6179 6180 6181 6182 6183 6184 6185 6186 6187 6188 6189 6190 6191 6192 6193 6194 6195 6196 6197 6198 6199 6200 6201 6202 6203 6204 6205 6206 6207 6208 6209 6210 6211 6212 6213 6214 6215 6216 6217 6218 6219 6220 6221 6222 6223 6224 6225 6226 6227 6228 6229 6230 6231 6232 6233 6234 6235 6236 6237 6238 6239 6240 6241 6242 6243 6244 6245 6246 6247 6248 6249 6250 6251 6252 6253 6254 6255 6256 6257 6258 6259 6260 6261 6262 6263 6264 6265 6266 6267 6268 6269 6270 6271 6272 6273 6274 6275 6276 6277 6278 6279 6280 6281 6282 6283 6284 6285 6286 6287 6288 6289 6290 6291 6292 6293 6294 6295 6296 6297 6298 6299 6300 6301 6302 6303 6304 6305 6306 6307 6308 6309 6310 6311 6312 6313 6314 6315 6316 6317 6318 6319 6320 6321 6322 6323 6324 6325 6326 6327 6328 6329 6330 6331 6332 6333 6334 6335 6336 6337 6338 6339 6340 6341 6342 6343 6344 6345 6346 6347 6348 6349 6350 6351 6352 6353 6354 6355 6356 6357 6358 6359 6360 6361 6362 6363 6364 6365 6366 6367 6368 6369 6370 6371 6372 6373 6374 6375 6376 6377 6378 6379 6380 6381 6382 6383 6384 6385 6386 6387 6388 6389 6390 6391 6392 6393 6394 6395 6396 6397 6398 6399 6400 6401 6402 6403 6404 6405 6406 6407 6408 6409 6410 6411 6412 6413 6414 6415 6416 6417 6418 6419 6420 6421 6422 6423 6424 6425 6426 6427 6428 6429 6430 6431 6432 6433 6434 6435 6436 6437 6438 6439 6440 6441 6442 6443 6444 6445 6446 6447 6448 6449 6450 6451 6452 6453 6454 6455 6456 6457 6458 6459 6460 6461 6462 6463 6464 6465 6466 6467 6468 6469 6470 6471 6472 6473 6474 6475 6476 6477 6478 6479 6480 6481 6482 6483 6484 6485 6486 6487 6488 6489 6490 6491 6492 6493 6494 6495 6496 6497 6498 6499 6500 6501 6502 6503 6504 6505 6506 6507 6508 6509 6510 6511 6512 6513 6514 6515 6516 6517 6518 6519 6520 6521 6522 6523 6524 6525 6526 6527 6528 6529 6530 6531 6532 6533 6534 6535 6536 6537 6538 6539 6540 6541 6542 6543 6544 6545 6546 6547 6548 6549 6550 6551 6552 6553 6554 6555 6556 6557 6558 6559 6560 6561 6562 6563 6564 6565 6566 6567 6568 6569 6570 6571 6572 6573 6574 6575 6576 6577 6578 6579 6580 6581 6582 6583 6584 6585 6586 6587 6588 6589 6590 6591 6592 6593 6594 6595 6596 6597 6598 6599 6600 6601 6602 6603 6604 6605 6606 6607 6608 6609 6610 6611 6612 6613 6614 6615 6616 6617 6618 6619 6620 6621 6622 6623 6624 6625 6626 6627 6628 6629 6630 6631 6632 6633 6634 6635 6636 6637 6638 6639 6640 6641 6642 6643 6644 6645 6646 6647 6648 6649 6650 6651 6652 6653 6654 6655 6656 6657 6658 6659 6660 6661 6662 6663 6664 6665 6666 6667 6668 6669 6670 6671 6672 6673 6674 6675 6676 6677 6678 6679 6680 6681 6682 6683 6684 6685 6686 6687 6688 6689 6690 6691 6692 6693 6694 6695 6696 6697 6698 6699 6700 6701 6702 6703 6704 6705 6706 6707 6708 6709 6710 6711 6712 6713 6714 6715 6716 6717 6718 6719 6720 6721 6722 6723 6724 6725 6726 6727 6728 6729 6730 6731 6732 6733 6734 6735 6736 6737 6738 6739 6740 6741 6742 6743 6744 6745 6746 6747 6748 6749 6750 6751 6752 6753 6754 6755 6756 6757 6758 6759 6760 6761 6762 6763 6764 6765 6766 6767 6768 6769 6770 6771 6772 6773 6774 6775 6776 6777 6778 6779 6780 6781 6782 6783 6784 6785 6786 6787 6788 6789 6790 6791 6792 6793 6794 6795 6796 6797 6798 6799 6800 6801 6802 6803 6804 6805 6806 6807 6808 6809 6810 6811 6812 6813 6814 6815 6816 6817 6818 6819 6820 6821 6822 6823 6824 6825 6826 6827 6828 6829 6830 6831 6832 6833 6834 6835 6836 6837 6838 6839 6840 6841 6842 6843 6844 6845 6846 6847 6848 6849 6850 6851 6852 6853 6854 6855 6856 6857 6858 6859 6860 6861 6862 6863 6864 6865 6866 6867 6868 6869 6870 6871 6872 6873 6874 6875 6876 6877 6878 6879 6880 6881 6882 6883 6884 6885 6886 6887 6888 6889 6890 6891 6892 6893 6894 6895 6896 6897 6898 6899 6900 6901 6902 6903 6904 6905 6906 6907 6908 6909 6910 6911 6912 6913 6914 6915 6916 6917 6918 6919 6920 6921 6922 6923 6924 6925 6926 6927 6928 6929 6930 6931 6932 6933 6934 6935 6936 6937 6938 6939 6940 6941 6942 6943 6944 6945 6946 6947 6948 6949 6950 6951 6952 6953 6954 6955 6956 6957 6958 6959 6960 6961 6962 6963 6964 6965 6966 6967 6968 6969 6970 6971 6972 6973 6974 6975 6976 6977 6978 6979 6980 6981 6982 6983 6984 6985 6986 6987 6988 6989 6990 6991 6992 6993 6994 6995 6996 6997 6998 6999 7000 7001 7002 7003 7004 7005 7006 7007 7008 7009 7010 7011 7012 7013 7014 7015 7016 7017 7018 7019 7020 7021 7022 7023 7024 7025 7026 7027 7028 7029 7030 7031 7032 7033 7034 7035 7036 7037 7038 7039 7040 7041 7042 7043 7044 7045 7046 7047 7048 7049 7050 7051 7052 7053 7054 7055 7056 7057 7058 7059 7060 7061 7062 7063 7064 7065 7066 7067 7068 7069 7070 7071 7072 7073 7074 7075 7076 7077 7078 7079 7080 7081 7082 7083 7084 7085 7086 7087 7088 7089 7090 7091 7092 7093 7094 7095 7096 7097 7098 7099 7100 7101 7102 7103 7104 7105 7106 7107 7108 7109 7110 7111 7112 7113 7114 7115 7116 7117 7118 7119 7120 7121 7122 7123 7124 7125 7126 7127 7128 7129 7130 7131 7132 7133 7134 7135 7136 7137 7138 7139 7140 7141 7142 7143 7144 7145 7146 7147 7148 7149 7150 7151 7152 7153 7154 7155 7156 7157 7158 7159 7160 7161 7162 7163 7164 7165 7166 7167 7168 7169 7170 7171 7172 7173 7174 7175 7176 7177 7178 7179 7180 7181 7182 7183 7184 7185 7186 7187 7188 7189 7190 7191 7192 7193 7194 7195 7196 7197 7198 7199 7200 7201 7202 7203 7204 7205 7206 7207 7208 7209 7210 7211 7212 7213 7214 7215 7216 7217 7218 7219 7220 7221 7222 7223 7224 7225 7226 7227 7228 7229 7230 7231 7232 7233 7234 7235 7236 7237 7238 7239 7240 7241 7242 7243 7244 7245 7246 7247 7248 7249 7250 7251 7252 7253 7254 7255 7256 7257 7258 7259 7260 7261 7262 7263 7264 7265 7266 7267 7268 7269 7270 7271 7272 7273 7274 7275 7276 7277 7278 7279 7280 7281 7282 7283 7284 7285 7286 7287 7288 7289 7290 7291 7292 7293 7294 7295 7296 7297 7298 7299 7300 7301 7302 7303 7304 7305 7306 7307 7308 7309 7310 7311 7312 7313 7314 7315 7316 7317 7318 7319 7320 7321 7322 7323 7324 7325 7326 7327 7328 7329 7330 7331 7332 7333 7334 7335 7336 7337 7338 7339 7340 7341 7342 7343 7344 7345 7346 7347 7348 7349 7350 7351 7352 7353 7354 7355 7356 7357 7358 7359 7360 7361 7362 7363 7364 7365 7366 7367 7368 7369 7370 7371 7372 7373 7374 7375 7376 7377 7378 7379 7380 7381 7382 7383 7384 7385 7386 7387 7388 7389 7390 7391 7392 7393 7394 7395 7396 7397 7398 7399 7400 7401 7402 7403 7404 7405 7406 7407 7408 7409 7410 7411 7412 7413 7414 7415 7416 7417 7418 7419 7420 7421 7422 7423 7424 7425 7426 7427 7428 7429 7430 7431 7432 7433 7434 7435 7436 7437 7438 7439 7440 7441 7442 7443 7444 7445 7446 7447 7448 7449 7450 7451 7452 7453 7454 7455 7456 7457 7458 7459 7460 7461 7462 7463 7464 7465 7466 7467 7468 7469 7470 7471 7472 7473 7474 7475 7476 7477 7478 7479 7480 7481 7482 7483 7484 7485 7486 7487 7488 7489 7490 7491 7492 7493 7494 7495 7496 7497 7498 7499 7500 7501 7502 7503 7504 7505 7506 7507 7508 7509 7510 7511 7512 7513 7514 7515 7516 7517 7518 7519 7520 7521 7522 7523 7524 7525 7526 7527 7528 7529 7530 7531 7532 7533 7534 7535 7536 7537 7538 7539 7540 7541 7542 7543 7544 7545 7546 7547 7548 7549 7550 7551 7552 7553 7554 7555 7556 7557 7558 7559 7560 7561 7562 7563 7564 7565 7566 7567 7568 7569 7570 7571 7572 7573 7574 7575 7576 7577 7578 7579 7580 7581 7582 7583 7584 7585 7586 7587 7588 7589 7590 7591 7592 7593 7594 7595 7596 7597 7598 7599 7600 7601 7602 7603 7604 7605 7606 7607 7608 7609 7610 7611 7612 7613 7614 7615 7616 7617 7618 7619 7620 7621 7622 7623 7624 7625 7626 7627 7628 7629 7630 7631 7632 7633 7634 7635 7636 7637 7638 7639 7640 7641 7642 7643 7644 7645 7646 7647 7648 7649 7650 7651 7652 7653 7654 7655 7656 7657 7658 7659 7660 7661 7662 7663 7664 7665 7666 7667 7668 7669 7670 7671 7672 7673 7674 7675 7676 7677 7678 7679 7680 7681 7682 7683 7684 7685 7686 7687 7688 7689 7690 7691 7692 7693 7694 7695 7696 7697 7698 7699 7700 7701 7702 7703 7704 7705 7706 7707 7708 7709 7710 7711 7712 7713 7714 7715 7716 7717 7718 7719 7720 7721 7722 7723 7724 7725 7726 7727 7728 7729 7730 7731 7732 7733 7734 7735 7736 7737 7738 7739 7740 7741 7742 7743 7744 7745 7746 7747 7748 7749 7750 7751 7752 7753 7754 7755 7756 7757 7758 7759 7760 7761 7762 7763 7764 7765 7766 7767 7768 7769 7770 7771 7772 7773 7774 7775 7776 7777 7778 7779 7780 7781 7782 7783 7784 7785 7786 7787 7788 7789 7790 7791 7792 7793 7794 7795 7796 7797 7798 7799 7800 7801 7802 7803 7804 7805 7806 7807 7808 7809 7810 7811 7812 7813 7814 7815 7816 7817 7818 7819 7820 7821 7822 7823 7824 7825 7826 7827 7828 7829 7830 7831 7832 7833 7834 7835 7836 7837 7838 7839 7840 7841 7842 7843 7844 7845 7846 7847 7848 7849 7850 7851 7852 7853 7854 7855 7856 7857 7858 7859 7860 7861 7862 7863 7864 7865 7866 7867 7868 7869 7870 7871 7872 7873 7874 7875 7876 7877 7878 7879 7880 7881 7882 7883 7884 7885 7886 7887 7888 7889 7890 7891 7892 7893 7894 7895 7896 7897 7898 7899 7900 7901 7902 7903 7904 7905 7906 7907 7908 7909 7910 7911 7912 7913 7914 7915 7916 7917 7918 7919 7920 7921 7922 7923 7924 7925 7926 7927 7928 7929 7930 7931 7932 7933 7934 7935 7936 7937 7938 7939 7940 7941 7942 7943 7944 7945 7946 7947 7948 7949 7950 7951 7952 7953 7954 7955 7956 7957 7958 7959 7960 7961 7962 7963 7964 7965 7966 7967 7968 7969 7970 7971 7972 7973 7974 7975 7976 7977 7978 7979 7980 7981 7982 7983 7984 7985 7986 7987 7988 7989 7990 7991 7992 7993 7994 7995 7996 7997 7998 7999 8000 8001 8002 8003 8004 8005 8006 8007 8008 8009 8010 8011 8012 8013 8014 8015 8016 8017 8018 8019 8020 8021 8022 8023 8024 8025 8026 8027 8028 8029 8030 8031 8032 8033 8034 8035 8036 8037 8038 8039 8040 8041 8042 8043 8044 8045 8046 8047 8048 8049 8050 8051 8052 8053 8054 8055 8056 8057 8058 8059 8060 8061 8062 8063 8064 8065 8066 8067 8068 8069 8070 8071 8072 8073 8074 8075 8076 8077 8078 8079 8080 8081 8082 8083 8084 8085 8086 8087 8088 8089 8090 8091 8092 8093 8094 8095 8096 8097 8098 8099 8100 8101 8102 8103 8104 8105 8106 8107 8108 8109 8110 8111 8112 8113 8114 8115 8116 8117 8118 8119 8120 8121 8122 8123 8124 8125 8126 8127 8128 8129 8130 8131 8132 8133 8134 8135 8136 8137 8138 8139 8140 8141 8142 8143 8144 8145 8146 8147 8148 8149 8150 8151 8152 8153 8154 8155 8156 8157 8158 8159 8160 8161 8162 8163 8164 8165 8166 8167 8168 8169 8170 8171 8172 8173 8174 8175 8176 8177 8178 8179 8180 8181 8182 8183 8184 8185 8186 8187 8188 8189 8190 8191 8192 8193 8194 8195 8196 8197 8198 8199 8200 8201 8202 8203 8204 8205 8206 8207 8208 8209 8210 8211 8212 8213 8214 8215 8216 8217 8218 8219 8220 8221 8222 8223 8224 8225 8226 8227 8228 8229 8230 8231 8232 8233 8234 8235 8236 8237 8238 8239 8240 8241 8242 8243 8244 8245 8246 8247 8248 8249 8250 8251 8252 8253 8254 8255 8256 8257 8258 8259 8260 8261 8262 8263 8264 8265 8266 8267 8268 8269 8270 8271 8272 8273 8274 8275 8276 8277 8278 8279 8280 8281 8282 8283 8284 8285 8286 8287 8288 8289 8290 8291 8292 8293 8294 8295 8296 8297 8298 8299 8300 8301 8302 8303 8304 8305 8306 8307 8308 8309 8310 8311 8312 8313 8314 8315 8316 8317 8318 8319 8320 8321 8322 8323 8324 8325 8326 8327 8328 8329 8330 8331 8332 8333 8334 8335 8336 8337 8338 8339 8340 8341 8342 8343 8344 8345 8346 8347 8348 8349 8350 8351 8352 8353 8354 8355 8356 8357 8358 8359 8360 8361 8362 8363 8364 8365 8366 8367 8368 8369 8370 8371 8372 8373 8374 8375 8376 8377 8378 8379 8380 8381 8382 8383 8384 8385 8386 8387 8388 8389 8390 8391 8392 8393 8394 8395 8396 8397 8398 8399 8400 8401 8402 8403 8404 8405 8406 8407 8408 8409 8410 8411 8412 8413 8414 8415 8416 8417 8418 8419 8420 8421 8422 8423 8424 8425 8426 8427 8428 8429 8430 8431 8432 8433 8434 8435 8436 8437 8438 8439 8440 8441 8442 8443 8444 8445 8446 8447 8448 8449 8450 8451 8452 8453 8454 8455 8456 8457 8458 8459 8460 8461 8462 8463 8464 8465 8466 8467 8468 8469 8470 8471 8472 8473 8474 8475 8476 8477 8478 8479 8480 8481 8482 8483 8484 8485 8486 8487 8488 8489 8490 8491 8492 8493 8494 8495 8496 8497 8498 8499 8500 8501 8502 8503 8504 8505 8506 8507 8508 8509 8510 8511 8512 8513 8514 8515 8516 8517 8518 8519 8520 8521 8522 8523 8524 8525 8526 8527 8528 8529 8530 8531 8532 8533 8534 8535 8536 8537 8538 8539 8540 8541 8542 8543 8544 8545 8546 8547 8548 8549 8550 8551 8552 8553 8554 8555 8556 8557 8558 8559 8560 8561 8562 8563 8564 8565 8566 8567 8568 8569 8570 8571 8572 8573 8574 8575 8576 8577 8578 8579 8580 8581 8582 8583 8584 8585 8586 8587 8588 8589 8590 8591 8592 8593 8594 8595 8596 8597 8598 8599 8600 8601 8602 8603 8604 8605 8606 8607 8608 8609 8610 8611 8612 8613 8614 8615 8616 8617 8618 8619 8620 8621 8622 8623 8624 8625 8626 8627 8628 8629 8630 8631 8632 8633 8634 8635 8636 8637 8638 8639 8640 8641 8642 8643 8644 8645 8646 8647 8648 8649 8650 8651 8652 8653 8654 8655 8656 8657 8658 8659 8660 8661 8662 8663 8664 8665 8666 8667 8668 8669 8670 8671 8672 8673 8674 8675 8676 8677 8678 8679 8680 8681 8682 8683 8684 8685 8686 8687 8688 8689 8690 8691 8692 8693 8694 8695 8696 8697 8698 8699 8700 8701 8702 8703 8704 8705 8706 8707 8708 8709 8710 8711 8712 8713 8714 8715 8716 8717 8718 8719 8720 8721 8722 8723 8724 8725 8726 8727 8728 8729 8730 8731 8732 8733 8734 8735 8736 8737 8738 8739 8740 8741 8742 8743 8744 8745 8746 8747 8748 8749 8750 8751 8752 8753 8754 8755 8756 8757 8758 8759 8760 8761 8762 8763 8764 8765 8766 8767 8768 8769 8770 8771 8772 8773 8774 8775 8776 8777 8778 8779 8780 8781 8782 8783 8784 8785 8786 8787 8788 8789 8790 8791 8792 8793 8794 8795 8796 8797 8798 8799 8800 8801 8802 8803 8804 8805 8806 8807 8808 8809 8810 8811 8812 8813 8814 8815 8816 8817 8818 8819 8820 8821 8822 8823 8824 8825 8826 8827 8828 8829 8830 8831 8832 8833 8834 8835 8836 8837 8838 8839 8840 8841 8842 8843 8844 8845 8846 8847 8848 8849 8850 8851 8852 8853 8854 8855 8856 8857 8858 8859 8860 8861 8862 8863 8864 8865 8866 8867 8868 8869 8870 8871 8872 8873 8874 8875 8876 8877 8878 8879 8880 8881 8882 8883 8884 8885 8886 8887 8888 8889 8890 8891 8892 8893 8894 8895 8896 8897 8898 8899 8900 8901 8902 8903 8904 8905 8906 8907 8908 8909 8910 8911 8912 8913 8914 8915 8916 8917 8918 8919 8920 8921 8922 8923 8924 8925 8926 8927 8928 8929 8930 8931 8932 8933 8934 8935 8936 8937 8938 8939 8940 8941 8942 8943 8944 8945 8946 8947 8948 8949 8950 8951 8952 8953 8954 8955 8956 8957 8958 8959 8960 8961 8962 8963 8964 8965 8966 8967 8968 8969 8970 8971 8972 8973 8974 8975 8976 8977 8978 8979 8980 8981 8982 8983 8984 8985 8986 8987 8988 8989 8990 8991 8992 8993 8994 8995 8996 8997 8998 8999 9000 9001 9002 9003 9004 9005 9006 9007 9008 9009 9010 9011 9012 9013 9014 9015 9016 9017 9018 9019 9020 9021 9022 9023 9024 9025 9026 9027 9028 9029 9030 9031 9032 9033 9034 9035 9036 9037 9038 9039 9040 9041 9042 9043 9044 9045 9046 9047 9048 9049 9050 9051 9052 9053 9054 9055 9056 9057 9058 9059 9060 9061 9062 9063 9064 9065 9066 9067 9068 9069 9070 9071 9072 9073 9074 9075 9076 9077 9078 9079 9080 9081 9082 9083 9084 9085 9086 9087 9088 9089 9090 9091 9092 9093 9094 9095 9096 9097 9098 9099 9100 9101 9102 9103 9104 9105 9106 9107 9108 9109 9110 9111 9112 9113 9114 9115 9116 9117 9118 9119 9120 9121 9122 9123 9124 9125 9126 9127 9128 9129 9130 9131 9132 9133 9134 9135 9136 9137 9138 9139 9140 9141 9142 9143 9144 9145 9146 9147 9148 9149 9150 9151 9152 9153 9154 9155 9156 9157 9158 9159 9160 9161 9162 9163 9164 9165 9166 9167 9168 9169 9170 9171 9172 9173 9174 9175 9176 9177 9178 9179 9180 9181 9182 9183 9184 9185 9186 9187 9188 9189 9190 9191 9192 9193 9194 9195 9196 9197 9198 9199 9200 9201 9202 9203 9204 9205 9206 9207 9208 9209 9210 9211 9212 9213 9214 9215 9216 9217 9218 9219 9220 9221 9222 9223 9224 9225 9226 9227 9228 9229 9230 9231 9232 9233 9234 9235
|
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html>
<html xmlns="http://www.w3.org/1999/xhtml">
<!--
This file is autogenerated from formatdomain.html.in
Do not edit this file. Changes will be lost.
-->
<!--
This page was generated at Thu Jan 10 20:48:17 UTC 2019.
-->
<head>
<meta charset="UTF-8"/>
<meta name="viewport" content="width=device-width, initial-scale=1"/>
<link rel="stylesheet" type="text/css" href="main.css"/>
<link rel="apple-touch-icon" sizes="180x180" href="/apple-touch-icon.png"/>
<link rel="icon" type="image/png" sizes="32x32" href="/favicon-32x32.png"/>
<link rel="icon" type="image/png" sizes="16x16" href="/favicon-16x16.png"/>
<link rel="manifest" href="/manifest.json"/>
<meta name="theme-color" content="#ffffff"/>
<title>libvirt: Domain XML format</title>
<meta name="description" content="libvirt, virtualization, virtualization API"/>
<script type="text/javascript">
<!--
function init() {
window.addEventListener('scroll', function(e){
var distanceY = window.pageYOffset || document.documentElement.scrollTop,
shrinkOn = 94
home = document.getElementById("home");
links = document.getElementById("jumplinks");
search = document.getElementById("search");
body = document.getElementById("body");
if (distanceY > shrinkOn) {
if (home.className != "navhide") {
body.className = "navhide"
home.className = "navhide"
links.className = "navhide"
search.className = "navhide"
}
} else {
if (home.className == "navhide") {
body.className = ""
home.className = ""
links.className = ""
search.className = ""
}
}
});
}
window.onload = init();
-->
</script>
</head>
<body>
<div id="body">
<div id="content">
<h1>Domain XML format</h1>
<ul>
<li>
<a href="#elements">Element and attribute overview</a>
<ul>
<li>
<a href="#elementsMetadata">General metadata</a>
</li>
<li>
<a href="#elementsOS">Operating system booting</a>
<ul>
<li>
<a href="#elementsOSBIOS">BIOS bootloader</a>
</li>
<li>
<a href="#elementsOSBootloader">Host bootloader</a>
</li>
<li>
<a href="#elementsOSKernel">Direct kernel boot</a>
</li>
<li>
<a href="#elementsOSContainer">Container boot</a>
</li>
</ul>
</li>
<li>
<a href="#elementsSysinfo">SMBIOS System Information</a>
</li>
<li>
<a href="#elementsCPUAllocation">CPU Allocation</a>
</li>
<li>
<a href="#elementsIOThreadsAllocation">IOThreads Allocation</a>
</li>
<li>
<a href="#elementsCPUTuning">CPU Tuning</a>
</li>
<li>
<a href="#elementsMemoryAllocation">Memory Allocation</a>
</li>
<li>
<a href="#elementsMemoryBacking">Memory Backing</a>
</li>
<li>
<a href="#elementsMemoryTuning">Memory Tuning</a>
</li>
<li>
<a href="#elementsNUMATuning">NUMA Node Tuning</a>
</li>
<li>
<a href="#elementsBlockTuning">Block I/O Tuning</a>
</li>
<li>
<a href="#resPartition">Resource partitioning</a>
</li>
<li>
<a href="#elementsCPU">CPU model and topology</a>
</li>
<li>
<a href="#elementsEvents">Events configuration</a>
</li>
<li>
<a href="#elementsPowerManagement">Power Management</a>
</li>
<li>
<a href="#elementsFeatures">Hypervisor features</a>
</li>
<li>
<a href="#elementsTime">Time keeping</a>
</li>
<li>
<a href="#elementsPerf">Performance monitoring events</a>
</li>
<li>
<a href="#elementsDevices">Devices</a>
<ul>
<li>
<a href="#elementsDisks">Hard drives, floppy disks, CDROMs</a>
</li>
<li>
<a href="#elementsFilesystems">Filesystems</a>
</li>
<li>
<a href="#elementsAddress">Device Addresses</a>
</li>
<li>
<a href="#elementsVirtio">Virtio-related options</a>
</li>
<li>
<a href="#elementsControllers">Controllers</a>
</li>
<li>
<a href="#elementsLease">Device leases</a>
</li>
<li>
<a href="#elementsHostDev">Host device assignment</a>
<ul>
<li>
<a href="#elementsHostDevSubsys">USB / PCI / SCSI devices</a>
</li>
<li>
<a href="#elementsHostDevCaps">Block / character devices</a>
</li>
</ul>
</li>
<li>
<a href="#elementsRedir">Redirected devices</a>
</li>
<li>
<a href="#elementsSmartcard">Smartcard devices</a>
</li>
<li>
<a href="#elementsNICS">Network interfaces</a>
<ul>
<li>
<a href="#elementsNICSVirtual">Virtual network</a>
</li>
<li>
<a href="#elementsNICSBridge">Bridge to LAN</a>
</li>
<li>
<a href="#elementsNICSSlirp">Userspace SLIRP stack</a>
</li>
<li>
<a href="#elementsNICSEthernet">Generic ethernet connection</a>
</li>
<li>
<a href="#elementsNICSDirect">Direct attachment to physical interface</a>
</li>
<li>
<a href="#elementsNICSHostdev">PCI Passthrough</a>
</li>
<li>
<a href="#elementsNICSMulticast">Multicast tunnel</a>
</li>
<li>
<a href="#elementsNICSTCP">TCP tunnel</a>
</li>
<li>
<a href="#elementsNICSUDP">UDP unicast tunnel</a>
</li>
<li>
<a href="#elementsNICSModel">Setting the NIC model</a>
</li>
<li>
<a href="#elementsDriverBackendOptions">Setting NIC driver-specific options</a>
</li>
<li>
<a href="#elementsBackendOptions">Setting network backend-specific options</a>
</li>
<li>
<a href="#elementsNICSTargetOverride">Overriding the target element</a>
</li>
<li>
<a href="#elementsNICSBoot">Specifying boot order</a>
</li>
<li>
<a href="#elementsNICSROM">Interface ROM BIOS configuration</a>
</li>
<li>
<a href="#elementDomain">Setting up a network backend in a driver domain</a>
</li>
<li>
<a href="#elementQoS">Quality of service</a>
</li>
<li>
<a href="#elementVlanTag">Setting VLAN tag (on supported network types only)</a>
</li>
<li>
<a href="#elementLink">Modifying virtual link state</a>
</li>
<li>
<a href="#mtu">MTU configuration</a>
</li>
<li>
<a href="#coalesce">Coalesce settings</a>
</li>
<li>
<a href="#ipconfig">IP configuration</a>
</li>
<li>
<a href="#elementVhostuser">vhost-user interface</a>
</li>
<li>
<a href="#elementNwfilter">Traffic filtering with NWFilter</a>
</li>
</ul>
</li>
<li>
<a href="#elementsInput">Input devices</a>
</li>
<li>
<a href="#elementsHub">Hub devices</a>
</li>
<li>
<a href="#elementsGraphics">Graphical framebuffers</a>
</li>
<li>
<a href="#elementsVideo">Video devices</a>
</li>
<li>
<a href="#elementsConsole">Consoles, serial, parallel & channel devices</a>
<ul>
<li>
<a href="#elementsCharGuestInterface">Guest interface</a>
<ul>
<li>
<a href="#elementCharParallel">Parallel port</a>
</li>
<li>
<a href="#elementCharSerial">Serial port</a>
</li>
<li>
<a href="#elementCharConsole">Console</a>
</li>
<li>
<a href="#elementCharSerialAndConsole">Relationship between serial ports and consoles</a>
</li>
<li>
<a href="#elementCharChannel">Channel</a>
</li>
</ul>
</li>
<li>
<a href="#elementsCharHostInterface">Host interface</a>
<ul>
<li>
<a href="#elementsCharSTDIO">Domain logfile</a>
</li>
<li>
<a href="#elementsCharFle">Device logfile</a>
</li>
<li>
<a href="#elementsCharVC">Virtual console</a>
</li>
<li>
<a href="#elementsCharNull">Null device</a>
</li>
<li>
<a href="#elementsCharPTY">Pseudo TTY</a>
</li>
<li>
<a href="#elementsCharHost">Host device proxy</a>
</li>
<li>
<a href="#elementsCharPipe">Named pipe</a>
</li>
<li>
<a href="#elementsCharTCP">TCP client/server</a>
</li>
<li>
<a href="#elementsCharUDP">UDP network console</a>
</li>
<li>
<a href="#elementsCharUNIX">UNIX domain socket client/server</a>
</li>
<li>
<a href="#elementsCharSpiceport">Spice channel</a>
</li>
<li>
<a href="#elementsNmdm">Nmdm device</a>
</li>
</ul>
</li>
</ul>
</li>
<li>
<a href="#elementsSound">Sound devices</a>
</li>
<li>
<a href="#elementsWatchdog">Watchdog device</a>
</li>
<li>
<a href="#elementsMemBalloon">Memory balloon device</a>
</li>
<li>
<a href="#elementsRng">Random number generator device</a>
</li>
<li>
<a href="#elementsTpm">TPM device</a>
</li>
<li>
<a href="#elementsNVRAM">NVRAM device</a>
</li>
<li>
<a href="#elementsPanic">panic device</a>
</li>
<li>
<a href="#elementsShmem">Shared memory device</a>
</li>
<li>
<a href="#elementsMemory">Memory devices</a>
</li>
<li>
<a href="#elementsIommu">IOMMU devices</a>
</li>
</ul>
</li>
<li>
<a href="#vsock">Vsock</a>
</li>
<li>
<a href="#seclabel">Security label</a>
</li>
<li>
<a href="#keywrap">Key Wrap</a>
</li>
<li>
<a href="#sev">Launch Security</a>
</li>
</ul>
</li>
<li>
<a href="#examples">Example configs</a>
</li>
</ul>
<p>
This section describes the XML format used to represent domains, there are
variations on the format based on the kind of domains run and the options
used to launch them. For hypervisor specific details consult the
<a href="drivers.html">driver docs</a>
</p>
<h2>
<a id="elements">Element and attribute overview</a>
<a class="headerlink" href="#elements" title="Permalink to this headline">¶</a>
</h2>
<p>
The root element required for all virtual machines is
named <code>domain</code>. It has two attributes, the
<a id="attributeDomainType"><code>type</code></a>
specifies the hypervisor used for running
the domain. The allowed values are driver specific, but
include "xen", "kvm", "qemu", "lxc" and "kqemu". The
second attribute is <code>id</code> which is a unique
integer identifier for the running guest machine. Inactive
machines have no id value.
</p>
<h3>
<a id="elementsMetadata">General metadata</a>
<a class="headerlink" href="#elementsMetadata" title="Permalink to this headline">¶</a>
</h3>
<pre>
<domain type='kvm' id='1'>
<name>MyGuest</name>
<uuid>4dea22b3-1d52-d8f3-2516-782e98ab3fa0</uuid>
<genid>43dc0cf8-809b-4adb-9bea-a9abb5f3d90e</genid>
<title>A short description - title - of the domain</title>
<description>Some human readable description</description>
<metadata>
<app1:foo xmlns:app1="http://app1.org/app1/">..</app1:foo>
<app2:bar xmlns:app2="http://app1.org/app2/">..</app2:bar>
</metadata>
...</pre>
<dl>
<dt>
<code>name</code>
</dt>
<dd>The content of the <code>name</code> element provides
a short name for the virtual machine. This name should
consist only of alpha-numeric characters and is required
to be unique within the scope of a single host. It is
often used to form the filename for storing the persistent
configuration file. <span class="since">Since 0.0.1</span></dd>
<dt>
<code>uuid</code>
</dt>
<dd>The content of the <code>uuid</code> element provides
a globally unique identifier for the virtual machine.
The format must be RFC 4122 compliant,
eg <code>3e3fce45-4f53-4fa7-bb32-11f34168b82b</code>.
If omitted when defining/creating a new machine, a random
UUID is generated. It is also possible to provide the UUID
via a <a href="#elementsSysinfo"><code>sysinfo</code></a>
specification. <span class="since">Since 0.0.1, sysinfo
since 0.8.7</span></dd>
<dt>
<code>genid</code>
</dt>
<dd><span class="since">Since 4.4.0</span>, the <code>genid</code>
element can be used to add a Virtual Machine Generation ID which
exposes a 128-bit, cryptographically random, integer value identifier,
referred to as a Globally Unique Identifier (GUID) using the same
format as the <code>uuid</code>. The value is used to help notify
the guest operating system when the virtual machine is re-executing
something that has already executed before, such as:
<ul><li>VM starts executing a snapshot</li><li>VM is recovered from backup</li><li>VM is failover in a disaster recovery environment</li><li>VM is imported, copied, or cloned</li></ul>
The guest operating system notices the change and is then able to
react as appropriate by marking its copies of distributed databases
as dirty, re-initializing its random number generator, etc.
<p>
The libvirt XML parser will accept both a provided GUID value
or just <genid/> in which case a GUID will be generated
and saved in the XML. For the transitions such as above, libvirt
will change the GUID before re-executing.</p></dd>
<dt>
<code>title</code>
</dt>
<dd>The optional element <code>title</code> provides space for a
short description of the domain. The title should not contain
any newlines. <span class="since">Since 0.9.10</span>.</dd>
<dt>
<code>description</code>
</dt>
<dd>The content of the <code>description</code> element provides a
human readable description of the virtual machine. This data is not
used by libvirt in any way, it can contain any information the user
wants. <span class="since">Since 0.7.2</span></dd>
<dt>
<code>metadata</code>
</dt>
<dd>The <code>metadata</code> node can be used by applications
to store custom metadata in the form of XML
nodes/trees. Applications must use custom namespaces on their
XML nodes/trees, with only one top-level element per namespace
(if the application needs structure, they should have
sub-elements to their namespace
element). <span class="since">Since 0.9.10</span></dd>
</dl>
<h3>
<a id="elementsOS">Operating system booting</a>
<a class="headerlink" href="#elementsOS" title="Permalink to this headline">¶</a>
</h3>
<p>
There are a number of different ways to boot virtual machines
each with their own pros and cons.
</p>
<h4>
<a id="elementsOSBIOS">BIOS bootloader</a>
<a class="headerlink" href="#elementsOSBIOS" title="Permalink to this headline">¶</a>
</h4>
<p>
Booting via the BIOS is available for hypervisors supporting
full virtualization. In this case the BIOS has a boot order
priority (floppy, harddisk, cdrom, network) determining where
to obtain/find the boot image.
</p>
<pre>
...
<os>
<type>hvm</type>
<loader readonly='yes' secure='no' type='rom'>/usr/lib/xen/boot/hvmloader</loader>
<nvram template='/usr/share/OVMF/OVMF_VARS.fd'>/var/lib/libvirt/nvram/guest_VARS.fd</nvram>
<boot dev='hd'/>
<boot dev='cdrom'/>
<bootmenu enable='yes' timeout='3000'/>
<smbios mode='sysinfo'/>
<bios useserial='yes' rebootTimeout='0'/>
</os>
...</pre>
<dl>
<dt>
<code>type</code>
</dt>
<dd>The content of the <code>type</code> element specifies the
type of operating system to be booted in the virtual machine.
<code>hvm</code> indicates that the OS is one designed to run
on bare metal, so requires full virtualization. <code>linux</code>
(badly named!) refers to an OS that supports the Xen 3 hypervisor
guest ABI. There are also two optional attributes, <code>arch</code>
specifying the CPU architecture to virtualization,
and <a id="attributeOSTypeMachine"><code>machine</code></a> referring
to the machine type. The <a href="formatcaps.html">Capabilities XML</a>
provides details on allowed values for
these. <span class="since">Since 0.0.1</span></dd>
<dt>
<a id="elementLoader">
<code>loader</code>
</a>
</dt>
<dd>The optional <code>loader</code> tag refers to a firmware blob,
which is specified by absolute path,
used to assist the domain creation process. It is used by Xen
fully virtualized domains as well as setting the QEMU BIOS file
path for QEMU/KVM domains. <span class="since">Xen since 0.1.0,
QEMU/KVM since 0.9.12</span> Then, <span class="since">since
1.2.8</span> it's possible for the element to have two
optional attributes: <code>readonly</code> (accepted values are
<code>yes</code> and <code>no</code>) to reflect the fact that the
image should be writable or read-only. The second attribute
<code>type</code> accepts values <code>rom</code> and
<code>pflash</code>. It tells the hypervisor where in the guest
memory the file should be mapped. For instance, if the loader
path points to an UEFI image, <code>type</code> should be
<code>pflash</code>. Moreover, some firmwares may
implement the Secure boot feature. Attribute
<code>secure</code> can be used then to control it.
<span class="since">Since 2.1.0</span></dd>
<dt>
<code>nvram</code>
</dt>
<dd>Some UEFI firmwares may want to use a non-volatile memory to store
some variables. In the host, this is represented as a file and the
absolute path to the file is stored in this element. Moreover, when the
domain is started up libvirt copies so called master NVRAM store file
defined in <code>qemu.conf</code>. If needed, the <code>template</code>
attribute can be used to per domain override map of master NVRAM stores
from the config file. Note, that for transient domains if the NVRAM file
has been created by libvirt it is left behind and it is management
application's responsibility to save and remove file (if needed to be
persistent). <span class="since">Since 1.2.8</span></dd>
<dt>
<code>boot</code>
</dt>
<dd>The <code>dev</code> attribute takes one of the values "fd", "hd",
"cdrom" or "network" and is used to specify the next boot device
to consider. The <code>boot</code> element can be repeated multiple
times to setup a priority list of boot devices to try in turn.
Multiple devices of the same type are sorted according to their
targets while preserving the order of buses. After defining the
domain, its XML configuration returned by libvirt (through
virDomainGetXMLDesc) lists devices in the sorted order. Once sorted,
the first device is marked as bootable. Thus, e.g., a domain
configured to boot from "hd" with vdb, hda, vda, and hdc disks
assigned to it will boot from vda (the sorted list is vda, vdb, hda,
hdc). Similar domain with hdc, vda, vdb, and hda disks will boot from
hda (sorted disks are: hda, hdc, vda, vdb). It can be tricky to
configure in the desired way, which is why per-device boot elements
(see <a href="#elementsDisks">disks</a>,
<a href="#elementsNICS">network interfaces</a>, and
<a href="#elementsHostDev">USB and PCI devices</a> sections below) were
introduced and they are the preferred way providing full control over
booting order. The <code>boot</code> element and per-device boot
elements are mutually exclusive. <span class="since">Since 0.1.3,
per-device boot since 0.8.8</span>
</dd>
<dt>
<code>smbios</code>
</dt>
<dd>How to populate SMBIOS information visible in the guest.
The <code>mode</code> attribute must be specified, and is either
"emulate" (let the hypervisor generate all values), "host" (copy
all of Block 0 and Block 1, except for the UUID, from the host's
SMBIOS values;
the <a href="html/libvirt-libvirt-host.html#virConnectGetSysinfo"><code>virConnectGetSysinfo</code></a> call can be
used to see what values are copied), or "sysinfo" (use the values in
the <a href="#elementsSysinfo">sysinfo</a> element). If not
specified, the hypervisor default is used. <span class="since">
Since 0.8.7</span>
</dd>
</dl>
<p>Up till here the BIOS/UEFI configuration knobs are generic enough to
be implemented by majority (if not all) firmwares out there. However,
from now on not every single setting makes sense to all firmwares. For
instance, <code>rebootTimeout</code> doesn't make sense for UEFI,
<code>useserial</code> might not be usable with a BIOS firmware that
doesn't produce any output onto serial line, etc. Moreover, firmwares
don't usually export their capabilities for libvirt (or users) to check.
And the set of their capabilities can change with every new release.
Hence users are advised to try the settings they use before relying on
them in production.</p>
<dl>
<dt>
<code>bootmenu</code>
</dt>
<dd> Whether or not to enable an interactive boot menu prompt on guest
startup. The <code>enable</code> attribute can be either "yes" or "no".
If not specified, the hypervisor default is used. <span class="since">
Since 0.8.3</span>
Additional attribute <code>timeout</code> takes the number of milliseconds
the boot menu should wait until it times out. Allowed values are numbers
in range [0, 65535] inclusive and it is ignored unless <code>enable</code>
is set to "yes". <span class="since">Since 1.2.8</span>
</dd>
<dt>
<code>bios</code>
</dt>
<dd>This element has attribute <code>useserial</code> with possible
values <code>yes</code> or <code>no</code>. It enables or disables
Serial Graphics Adapter which allows users to see BIOS messages
on a serial port. Therefore, one needs to have
<a href="#elementCharSerial">serial port</a> defined.
<span class="since">Since 0.9.4</span>.
<span class="since">Since 0.10.2 (QEMU only)</span> there is
another attribute, <code>rebootTimeout</code> that controls
whether and after how long the guest should start booting
again in case the boot fails (according to BIOS). The value is
in milliseconds with maximum of <code>65535</code> and special
value <code>-1</code> disables the reboot.
</dd>
</dl>
<h4>
<a id="elementsOSBootloader">Host bootloader</a>
<a class="headerlink" href="#elementsOSBootloader" title="Permalink to this headline">¶</a>
</h4>
<p>
Hypervisors employing paravirtualization do not usually emulate
a BIOS, and instead the host is responsible to kicking off the
operating system boot. This may use a pseudo-bootloader in the
host to provide an interface to choose a kernel for the guest.
An example is <code>pygrub</code> with Xen. The Bhyve hypervisor
also uses a host bootloader, either <code>bhyveload</code> or
<code>grub-bhyve</code>.
</p>
<pre>
...
<bootloader>/usr/bin/pygrub</bootloader>
<bootloader_args>--append single</bootloader_args>
...</pre>
<dl>
<dt>
<code>bootloader</code>
</dt>
<dd>The content of the <code>bootloader</code> element provides
a fully qualified path to the bootloader executable in the
host OS. This bootloader will be run to choose which kernel
to boot. The required output of the bootloader is dependent
on the hypervisor in use. <span class="since">Since 0.1.0</span></dd>
<dt>
<code>bootloader_args</code>
</dt>
<dd>The optional <code>bootloader_args</code> element allows
command line arguments to be passed to the bootloader.
<span class="since">Since 0.2.3</span>
</dd>
</dl>
<h4>
<a id="elementsOSKernel">Direct kernel boot</a>
<a class="headerlink" href="#elementsOSKernel" title="Permalink to this headline">¶</a>
</h4>
<p>
When installing a new guest OS it is often useful to boot directly
from a kernel and initrd stored in the host OS, allowing command
line arguments to be passed directly to the installer. This capability
is usually available for both para and full virtualized guests.
</p>
<pre>
...
<os>
<type>hvm</type>
<loader>/usr/lib/xen/boot/hvmloader</loader>
<kernel>/root/f8-i386-vmlinuz</kernel>
<initrd>/root/f8-i386-initrd</initrd>
<cmdline>console=ttyS0 ks=http://example.com/f8-i386/os/</cmdline>
<dtb>/root/ppc.dtb</dtb>
<acpi>
<table type='slic'>/path/to/slic.dat</table>
</acpi>
</os>
...</pre>
<dl>
<dt>
<code>type</code>
</dt>
<dd>This element has the same semantics as described earlier in the
<a href="#elementsOSBIOS">BIOS boot section</a></dd>
<dt>
<code>loader</code>
</dt>
<dd>This element has the same semantics as described earlier in the
<a href="#elementsOSBIOS">BIOS boot section</a></dd>
<dt>
<code>kernel</code>
</dt>
<dd>The contents of this element specify the fully-qualified path
to the kernel image in the host OS.</dd>
<dt>
<code>initrd</code>
</dt>
<dd>The contents of this element specify the fully-qualified path
to the (optional) ramdisk image in the host OS.</dd>
<dt>
<code>cmdline</code>
</dt>
<dd>The contents of this element specify arguments to be passed to
the kernel (or installer) at boot time. This is often used to
specify an alternate primary console (eg serial port), or the
installation media source / kickstart file</dd>
<dt>
<code>dtb</code>
</dt>
<dd>The contents of this element specify the fully-qualified path
to the (optional) device tree binary (dtb) image in the host OS.
<span class="since">Since 1.0.4</span></dd>
<dt>
<code>acpi</code>
</dt>
<dd>The <code>table</code> element contains a fully-qualified path
to the ACPI table. The <code>type</code> attribute contains the
ACPI table type (currently only <code>slic</code> is supported)
<span class="since">Since 1.3.5 (QEMU only)</span></dd>
</dl>
<h4>
<a id="elementsOSContainer">Container boot</a>
<a class="headerlink" href="#elementsOSContainer" title="Permalink to this headline">¶</a>
</h4>
<p>
When booting a domain using container based virtualization, instead
of a kernel / boot image, a path to the init binary is required, using
the <code>init</code> element. By default this will be launched with
no arguments. To specify the initial argv, use the <code>initarg</code>
element, repeated as many time as is required. The <code>cmdline</code>
element, if set will be used to provide an equivalent to <code>/proc/cmdline</code>
but will not affect init argv.
</p>
<p>
To set environment variables, use the <code>initenv</code> element, one
for each variable.
</p>
<p>
To set a custom work directory for the init, use the <code>initdir</code>
element.
</p>
<p>
To run the init command as a given user or group, use the <code>inituser</code>
or <code>initgroup</code> elements respectively. Both elements can be provided
either a user (resp. group) id or a name. Prefixing the user or group id with
a <code>+</code> will force it to be considered like a numeric value. Without
this, it will be first tried as a user or group name.
</p>
<pre>
<os>
<type arch='x86_64'>exe</type>
<init>/bin/systemd</init>
<initarg>--unit</initarg>
<initarg>emergency.service</initarg>
<initenv name='MYENV'>some value</initenv>
<initdir>/my/custom/cwd</initdir>
<inituser>tester</inituser>
<initgroup>1000</initgroup>
</os>
</pre>
<p>
If you want to enable user namespace, set the <code>idmap</code> element.
The <code>uid</code> and <code>gid</code> elements have three attributes:
</p>
<dl>
<dt>
<code>start</code>
</dt>
<dd>First user ID in container. It must be '0'.</dd>
<dt>
<code>target</code>
</dt>
<dd>The first user ID in container will be mapped to this target user
ID in host.</dd>
<dt>
<code>count</code>
</dt>
<dd>How many users in container are allowed to map to host's user.</dd>
</dl>
<pre>
<idmap>
<uid start='0' target='1000' count='10'/>
<gid start='0' target='1000' count='10'/>
</idmap>
</pre>
<h3>
<a id="elementsSysinfo">SMBIOS System Information</a>
<a class="headerlink" href="#elementsSysinfo" title="Permalink to this headline">¶</a>
</h3>
<p>
Some hypervisors allow control over what system information is
presented to the guest (for example, SMBIOS fields can be
populated by a hypervisor and inspected via
the <code>dmidecode</code> command in the guest). The
optional <code>sysinfo</code> element covers all such categories
of information. <span class="since">Since 0.8.7</span>
</p>
<pre>
...
<os>
<smbios mode='sysinfo'/>
...
</os>
<sysinfo type='smbios'>
<bios>
<entry name='vendor'>LENOVO</entry>
</bios>
<system>
<entry name='manufacturer'>Fedora</entry>
<entry name='product'>Virt-Manager</entry>
<entry name='version'>0.9.4</entry>
</system>
<baseBoard>
<entry name='manufacturer'>LENOVO</entry>
<entry name='product'>20BE0061MC</entry>
<entry name='version'>0B98401 Pro</entry>
<entry name='serial'>W1KS427111E</entry>
</baseBoard>
<chassis>
<entry name='manufacturer'>Dell Inc.</entry>
<entry name='version'>2.12</entry>
<entry name='serial'>65X0XF2</entry>
<entry name='asset'>40000101</entry>
<entry name='sku'>Type3Sku1</entry>
</chassis>
<oemStrings>
<entry>myappname:some arbitrary data</entry>
<entry>otherappname:more arbitrary data</entry>
</oemStrings>
</sysinfo>
...</pre>
<p>
The <code>sysinfo</code> element has a mandatory
attribute <code>type</code> that determine the layout of
sub-elements, with supported values of:
</p>
<dl>
<dt>
<code>smbios</code>
</dt>
<dd>Sub-elements call out specific SMBIOS values, which will
affect the guest if used in conjunction with
the <code>smbios</code> sub-element of
the <a href="#elementsOS"><code>os</code></a> element. Each
sub-element of <code>sysinfo</code> names a SMBIOS block, and
within those elements can be a list of <code>entry</code>
elements that describe a field within the block. The following
blocks and entries are recognized:
<dl><dt><code>bios</code></dt><dd>
This is block 0 of SMBIOS, with entry names drawn from:
<dl><dt><code>vendor</code></dt><dd>BIOS Vendor's Name</dd><dt><code>version</code></dt><dd>BIOS Version</dd><dt><code>date</code></dt><dd>BIOS release date. If supplied, is in either mm/dd/yy or
mm/dd/yyyy format. If the year portion of the string is
two digits, the year is assumed to be 19yy.</dd><dt><code>release</code></dt><dd>System BIOS Major and Minor release number values
concatenated together as one string separated by
a period, for example, 10.22.</dd></dl>
</dd><dt><code>system</code></dt><dd>
This is block 1 of SMBIOS, with entry names drawn from:
<dl><dt><code>manufacturer</code></dt><dd>Manufacturer of BIOS</dd><dt><code>product</code></dt><dd>Product Name</dd><dt><code>version</code></dt><dd>Version of the product</dd><dt><code>serial</code></dt><dd>Serial number</dd><dt><code>uuid</code></dt><dd>Universal Unique ID number. If this entry is provided
alongside a top-level
<a href="#elementsMetadata"><code>uuid</code></a> element,
then the two values must match.</dd><dt><code>sku</code></dt><dd>SKU number to identify a particular configuration.</dd><dt><code>family</code></dt><dd>Identify the family a particular computer belongs to.</dd></dl>
</dd><dt><code>baseBoard</code></dt><dd>
This is block 2 of SMBIOS. This element can be repeated multiple
times to describe all the base boards; however, not all
hypervisors necessarily support the repetition. The element can
have the following children:
<dl><dt><code>manufacturer</code></dt><dd>Manufacturer of BIOS</dd><dt><code>product</code></dt><dd>Product Name</dd><dt><code>version</code></dt><dd>Version of the product</dd><dt><code>serial</code></dt><dd>Serial number</dd><dt><code>asset</code></dt><dd>Asset tag</dd><dt><code>location</code></dt><dd>Location in chassis</dd></dl>
NB: Incorrectly supplied entries for the
<code>bios</code>, <code>system</code> or <code>baseBoard</code>
blocks will be ignored without error. Other than <code>uuid</code>
validation and <code>date</code> format checking, all values are
passed as strings to the hypervisor driver.
</dd><dt><code>chassis</code></dt><dd><span class="since">Since 4.1.0,</span> this is block 3 of
SMBIOS, with entry names drawn from:
<dl><dt><code>manufacturer</code></dt><dd>Manufacturer of Chassis</dd><dt><code>version</code></dt><dd>Version of the Chassis</dd><dt><code>serial</code></dt><dd>Serial number</dd><dt><code>asset</code></dt><dd>Asset tag</dd><dt><code>sku</code></dt><dd>SKU number</dd></dl>
</dd><dt><code>oemStrings</code></dt><dd>
This is block 11 of SMBIOS. This element should appear once and
can have multiple <code>entry</code> child elements, each providing
arbitrary string data. There are no restrictions on what data can
be provided in the entries, however, if the data is intended to be
consumed by an application in the guest, it is recommended to use
the application name as a prefix in the string. (<span class="since">Since 4.1.0</span>)
</dd></dl>
</dd>
</dl>
<h3>
<a id="elementsCPUAllocation">CPU Allocation</a>
<a class="headerlink" href="#elementsCPUAllocation" title="Permalink to this headline">¶</a>
</h3>
<pre>
<domain>
...
<vcpu placement='static' cpuset="1-4,^3,6" current="1">2</vcpu>
<vcpus>
<vcpu id='0' enabled='yes' hotpluggable='no' order='1'/>
<vcpu id='1' enabled='no' hotpluggable='yes'/>
</vcpus>
...
</domain>
</pre>
<dl>
<dt>
<code>vcpu</code>
</dt>
<dd>The content of this element defines the maximum number of virtual
CPUs allocated for the guest OS, which must be between 1 and
the maximum supported by the hypervisor.
<dl><dt><code>cpuset</code></dt><dd>
The optional attribute <code>cpuset</code> is a comma-separated
list of physical CPU numbers that domain process and virtual CPUs
can be pinned to by default. (NB: The pinning policy of domain
process and virtual CPUs can be specified separately by
<code>cputune</code>. If the attribute <code>emulatorpin</code>
of <code>cputune</code> is specified, the <code>cpuset</code>
specified by <code>vcpu</code> here will be ignored. Similarly,
for virtual CPUs which have the <code>vcpupin</code> specified,
the <code>cpuset</code> specified by <code>cpuset</code> here
will be ignored. For virtual CPUs which don't have
<code>vcpupin</code> specified, each will be pinned to the physical
CPUs specified by <code>cpuset</code> here).
Each element in that list is either a single CPU number,
a range of CPU numbers, or a caret followed by a CPU number to
be excluded from a previous range.
<span class="since">Since 0.4.4</span>
</dd><dt><code>current</code></dt><dd>
The optional attribute <code>current</code> can
be used to specify whether fewer than the maximum number of
virtual CPUs should be enabled.
<span class="since">Since 0.8.5</span>
</dd><dt><code>placement</code></dt><dd>
The optional attribute <code>placement</code> can be used to
indicate the CPU placement mode for domain process. The value can
be either "static" or "auto", but defaults to <code>placement</code>
of <code>numatune</code> or "static" if <code>cpuset</code> is
specified. Using "auto" indicates the domain process will be pinned
to the advisory nodeset from querying numad and the value of
attribute <code>cpuset</code> will be ignored if it's specified.
If both <code>cpuset</code> and <code>placement</code> are not
specified or if <code>placement</code> is "static", but no
<code>cpuset</code> is specified, the domain process will be
pinned to all the available physical CPUs.
<span class="since">Since 0.9.11 (QEMU and KVM only)</span>
</dd></dl>
</dd>
<dt>
<code>vcpus</code>
</dt>
<dd>
The vcpus element allows to control state of individual vCPUs.
The <code>id</code> attribute specifies the vCPU id as used by libvirt
in other places such as vCPU pinning, scheduler information and NUMA
assignment. Note that the vCPU ID as seen in the guest may differ from
libvirt ID in certain cases. Valid IDs are from 0 to the maximum vCPU
count as set by the <code>vcpu</code> element minus 1.
The <code>enabled</code> attribute allows to control the state of the
vCPU. Valid values are <code>yes</code> and <code>no</code>.
<code>hotpluggable</code> controls whether given vCPU can be hotplugged
and hotunplugged in cases when the CPU is enabled at boot. Note that
all disabled vCPUs must be hotpluggable. Valid values are
<code>yes</code> and <code>no</code>.
<code>order</code> allows to specify the order to add the online vCPUs.
For hypervisors/platforms that require to insert multiple vCPUs at once
the order may be duplicated across all vCPUs that need to be
enabled at once. Specifying order is not necessary, vCPUs are then
added in an arbitrary order. If order info is used, it must be used for
all online vCPUs. Hypervisors may clear or update ordering information
during certain operations to assure valid configuration.
Note that hypervisors may create hotpluggable vCPUs differently from
boot vCPUs thus special initialization may be necessary.
Hypervisors may require that vCPUs enabled on boot which are not
hotpluggable are clustered at the beginning starting with ID 0. It may
be also required that vCPU 0 is always present and non-hotpluggable.
Note that providing state for individual CPUs may be necessary to enable
support of addressable vCPU hotplug and this feature may not be
supported by all hypervisors.
For QEMU the following conditions are required. vCPU 0 needs to be
enabled and non-hotpluggable. On PPC64 along with it vCPUs that are in
the same core need to be enabled as well. All non-hotpluggable CPUs
present at boot need to be grouped after vCPU 0.
<span class="since">Since 2.2.0 (QEMU only)</span>
</dd>
</dl>
<h3>
<a id="elementsIOThreadsAllocation">IOThreads Allocation</a>
<a class="headerlink" href="#elementsIOThreadsAllocation" title="Permalink to this headline">¶</a>
</h3>
<p>
IOThreads are dedicated event loop threads for supported disk
devices to perform block I/O requests in order to improve
scalability especially on an SMP host/guest with many LUNs.
<span class="since">Since 1.2.8 (QEMU only)</span>
</p>
<pre>
<domain>
...
<iothreads>4</iothreads>
...
</domain>
</pre>
<pre>
<domain>
...
<iothreadids>
<iothread id="2"/>
<iothread id="4"/>
<iothread id="6"/>
<iothread id="8"/>
</iothreadids>
...
</domain>
</pre>
<dl>
<dt>
<code>iothreads</code>
</dt>
<dd>
The content of this optional element defines the number
of IOThreads to be assigned to the domain for use by
supported target storage devices. There
should be only 1 or 2 IOThreads per host CPU. There may be more
than one supported device assigned to each IOThread.
<span class="since">Since 1.2.8</span>
</dd>
<dt>
<code>iothreadids</code>
</dt>
<dd>
The optional <code>iothreadids</code> element provides the capability
to specifically define the IOThread ID's for the domain. By default,
IOThread ID's are sequentially numbered starting from 1 through the
number of <code>iothreads</code> defined for the domain. The
<code>id</code> attribute is used to define the IOThread ID. The
<code>id</code> attribute must be a positive integer greater than 0.
If there are less <code>iothreadids</code> defined than
<code>iothreads</code> defined for the domain, then libvirt will
sequentially fill <code>iothreadids</code> starting at 1 avoiding
any predefined <code>id</code>. If there are more
<code>iothreadids</code> defined than <code>iothreads</code>
defined for the domain, then the <code>iothreads</code> value
will be adjusted accordingly.
<span class="since">Since 1.2.15</span>
</dd>
</dl>
<h3>
<a id="elementsCPUTuning">CPU Tuning</a>
<a class="headerlink" href="#elementsCPUTuning" title="Permalink to this headline">¶</a>
</h3>
<pre>
<domain>
...
<cputune>
<vcpupin vcpu="0" cpuset="1-4,^2"/>
<vcpupin vcpu="1" cpuset="0,1"/>
<vcpupin vcpu="2" cpuset="2,3"/>
<vcpupin vcpu="3" cpuset="0,4"/>
<emulatorpin cpuset="1-3"/>
<iothreadpin iothread="1" cpuset="5,6"/>
<iothreadpin iothread="2" cpuset="7,8"/>
<shares>2048</shares>
<period>1000000</period>
<quota>-1</quota>
<global_period>1000000</global_period>
<global_quota>-1</global_quota>
<emulator_period>1000000</emulator_period>
<emulator_quota>-1</emulator_quota>
<iothread_period>1000000</iothread_period>
<iothread_quota>-1</iothread_quota>
<vcpusched vcpus='0-4,^3' scheduler='fifo' priority='1'/>
<iothreadsched iothreads='2' scheduler='batch'/>
<cachetune vcpus='0-3'>
<cache id='0' level='3' type='both' size='3' unit='MiB'/>
<cache id='1' level='3' type='both' size='3' unit='MiB'/>
<monitor level='3' vcpus='1'/>
<monitor level='3' vcpus='0-3'/>
</cachetune>
<cachetune vcpus='4-5'>
<monitor level='3' vcpus='4'/>
<monitor level='3' vcpus='5'/>
</cachetune>
<memorytune vcpus='0-3'>
<node id='0' bandwidth='60'/>
</memorytune>
</cputune>
...
</domain>
</pre>
<dl>
<dt>
<code>cputune</code>
</dt>
<dd>
The optional <code>cputune</code> element provides details
regarding the CPU tunable parameters for the domain.
<span class="since">Since 0.9.0</span>
</dd>
<dt>
<code>vcpupin</code>
</dt>
<dd>
The optional <code>vcpupin</code> element specifies which of host's
physical CPUs the domain vCPU will be pinned to. If this is omitted,
and attribute <code>cpuset</code> of element <code>vcpu</code> is
not specified, the vCPU is pinned to all the physical CPUs by default.
It contains two required attributes, the attribute <code>vcpu</code>
specifies vCPU id, and the attribute <code>cpuset</code> is same as
attribute <code>cpuset</code> of element <code>vcpu</code>.
(NB: Only qemu driver support)
<span class="since">Since 0.9.0</span>
</dd>
<dt>
<code>emulatorpin</code>
</dt>
<dd>
The optional <code>emulatorpin</code> element specifies which of host
physical CPUs the "emulator", a subset of a domain not including vCPU
or iothreads will be pinned to. If this is omitted, and attribute
<code>cpuset</code> of element <code>vcpu</code> is not specified,
"emulator" is pinned to all the physical CPUs by default. It contains
one required attribute <code>cpuset</code> specifying which physical
CPUs to pin to.
</dd>
<dt>
<code>iothreadpin</code>
</dt>
<dd>
The optional <code>iothreadpin</code> element specifies which of host
physical CPUs the IOThreads will be pinned to. If this is omitted
and attribute <code>cpuset</code> of element <code>vcpu</code> is
not specified, the IOThreads are pinned to all the physical CPUs
by default. There are two required attributes, the attribute
<code>iothread</code> specifies the IOThread ID and the attribute
<code>cpuset</code> specifying which physical CPUs to pin to. See
the <code>iothreadids</code>
<a href="#elementsIOThreadsAllocation"><code>description</code></a>
for valid <code>iothread</code> values.
<span class="since">Since 1.2.9</span>
</dd>
<dt>
<code>shares</code>
</dt>
<dd>
The optional <code>shares</code> element specifies the proportional
weighted share for the domain. If this is omitted, it defaults to
the OS provided defaults. NB, There is no unit for the value,
it's a relative measure based on the setting of other VM,
e.g. A VM configured with value
2048 will get twice as much CPU time as a VM configured with value 1024.
<span class="since">Since 0.9.0</span>
</dd>
<dt>
<code>period</code>
</dt>
<dd>
The optional <code>period</code> element specifies the enforcement
interval (unit: microseconds). Within <code>period</code>, each vCPU of
the domain will not be allowed to consume more than <code>quota</code>
worth of runtime. The value should be in range [1000, 1000000]. A period
with value 0 means no value.
<span class="since">Only QEMU driver support since 0.9.4, LXC since
0.9.10</span>
</dd>
<dt>
<code>quota</code>
</dt>
<dd>
The optional <code>quota</code> element specifies the maximum allowed
bandwidth (unit: microseconds). A domain with <code>quota</code> as any
negative value indicates that the domain has infinite bandwidth for
vCPU threads, which means that it is not bandwidth controlled. The value
should be in range [1000, 18446744073709551] or less than 0. A quota
with value 0 means no value. You can use this feature to ensure that all
vCPUs run at the same speed.
<span class="since">Only QEMU driver support since 0.9.4, LXC since
0.9.10</span>
</dd>
<dt>
<code>global_period</code>
</dt>
<dd>
The optional <code>global_period</code> element specifies the
enforcement CFS scheduler interval (unit: microseconds) for the whole
domain in contrast with <code>period</code> which enforces the interval
per vCPU. The value should be in range 1000, 1000000]. A
<code>global_period</code> with value 0 means no value.
<span class="since">Only QEMU driver support since 1.3.3</span>
</dd>
<dt>
<code>global_quota</code>
</dt>
<dd>
The optional <code>global_quota</code> element specifies the maximum
allowed bandwidth (unit: microseconds) within a period for the whole
domain. A domain with <code>global_quota</code> as any negative
value indicates that the domain has infinite bandwidth, which means that
it is not bandwidth controlled. The value should be in range
[1000, 18446744073709551] or less than 0. A <code>global_quota</code>
with value 0 means no value.
<span class="since">Only QEMU driver support since 1.3.3</span>
</dd>
<dt>
<code>emulator_period</code>
</dt>
<dd>
The optional <code>emulator_period</code> element specifies the enforcement
interval (unit: microseconds). Within <code>emulator_period</code>, emulator
threads (those excluding vCPUs) of the domain will not be allowed to consume
more than <code>emulator_quota</code> worth of runtime. The value should be
in range [1000, 1000000]. A period with value 0 means no value.
<span class="since">Only QEMU driver support since 0.10.0</span>
</dd>
<dt>
<code>emulator_quota</code>
</dt>
<dd>
The optional <code>emulator_quota</code> element specifies the maximum
allowed bandwidth (unit: microseconds) for domain's emulator threads (those
excluding vCPUs). A domain with <code>emulator_quota</code> as any negative
value indicates that the domain has infinite bandwidth for emulator threads
(those excluding vCPUs), which means that it is not bandwidth controlled.
The value should be in range [1000, 18446744073709551] or less than 0. A
quota with value 0 means no value.
<span class="since">Only QEMU driver support since 0.10.0</span>
</dd>
<dt>
<code>iothread_period</code>
</dt>
<dd>
The optional <code>iothread_period</code> element specifies the
enforcement interval (unit: microseconds) for IOThreads. Within
<code>iothread_period</code>, each IOThread of the domain will
not be allowed to consume more than <code>iothread_quota</code>
worth of runtime. The value should be in range [1000, 1000000].
An iothread_period with value 0 means no value.
<span class="since">Only QEMU driver support since 2.1.0</span>
</dd>
<dt>
<code>iothread_quota</code>
</dt>
<dd>
The optional <code>iothread_quota</code> element specifies the maximum
allowed bandwidth (unit: microseconds) for IOThreads. A domain with
<code>iothread_quota</code> as any negative value indicates that the
domain IOThreads have infinite bandwidth, which means that it is
not bandwidth controlled. The value should be in range
[1000, 18446744073709551] or less than 0. An <code>iothread_quota</code>
with value 0 means no value. You can use this feature to ensure that
all IOThreads run at the same speed.
<span class="since">Only QEMU driver support since 2.1.0</span>
</dd>
<dt><code>vcpusched</code> and <code>iothreadsched</code></dt>
<dd>
The optional <code>vcpusched</code> elements specifies the scheduler
type (values <code>batch</code>, <code>idle</code>, <code>fifo</code>,
<code>rr</code>) for particular vCPU/IOThread threads (based on
<code>vcpus</code> and <code>iothreads</code>, leaving out
<code>vcpus</code>/<code>iothreads</code> sets the default). Valid
<code>vcpus</code> values start at 0 through one less than the
number of vCPU's defined for the domain. Valid <code>iothreads</code>
values are described in the <code>iothreadids</code>
<a href="#elementsIOThreadsAllocation"><code>description</code></a>.
If no <code>iothreadids</code> are defined, then libvirt numbers
IOThreads from 1 to the number of <code>iothreads</code> available
for the domain. For real-time schedulers (<code>fifo</code>,
<code>rr</code>), priority must be specified as
well (and is ignored for non-real-time ones). The value range
for the priority depends on the host kernel (usually 1-99).
<span class="since">Since 1.2.13</span>
</dd>
<dt>
<code>cachetune</code>
<span class="since">Since 4.1.0</span>
</dt>
<dd>
Optional <code>cachetune</code> element can control allocations for CPU
caches using the resctrl on the host. Whether or not is this supported
can be gathered from capabilities where some limitations like minimum
size and required granularity are reported as well. The required
attribute <code>vcpus</code> specifies to which vCPUs this allocation
applies. A vCPU can only be member of one <code>cachetune</code> element
allocation. The vCPUs specified by cachetune can be identical with those
in memorytune, however they are not allowed to overlap.
Supported subelements are:
<dl><dt><code>cache</code></dt><dd>
This optional element controls the allocation of CPU cache and has
the following attributes:
<dl><dt><code>level</code></dt><dd>
Host cache level from which to allocate.
</dd><dt><code>id</code></dt><dd>
Host cache id from which to allocate.
</dd><dt><code>type</code></dt><dd>
Type of allocation. Can be <code>code</code> for code
(instructions), <code>data</code> for data or <code>both</code>
for both code and data (unified). Currently the allocation can
be done only with the same type as the host supports, meaning
you cannot request <code>both</code> for host with CDP
(code/data prioritization) enabled.
</dd><dt><code>size</code></dt><dd>
The size of the region to allocate. The value by default is in
bytes, but the <code>unit</code> attribute can be used to scale
the value.
</dd><dt><code>unit</code> (optional)</dt><dd>
If specified it is the unit such as KiB, MiB, GiB, or TiB
(described in the <code>memory</code> element
for <a href="#elementsMemoryAllocation">Memory Allocation</a>)
in which <code>size</code> is specified, defaults to bytes.
</dd></dl>
</dd><dt><code>monitor</code><span class="since">Since 4.10.0</span></dt><dd>
The optional element <code>monitor</code> creates the cache
monitor(s) for current cache allocation and has the following
required attributes:
<dl><dt><code>level</code></dt><dd>
Host cache level the monitor belongs to.
</dd><dt><code>vcpus</code></dt><dd>
vCPU list the monitor applies to. A monitor's vCPU list
can only be the member(s) of the vCPU list of the associated
allocation. The default monitor has the same vCPU list as the
associated allocation. For non-default monitors, overlapping
vCPUs are not permitted.
</dd></dl>
</dd></dl>
</dd>
<dt>
<code>memorytune</code>
<span class="since">Since 4.7.0</span>
</dt>
<dd>
Optional <code>memorytune</code> element can control allocations for
memory bandwidth using the resctrl on the host. Whether or not is this
supported can be gathered from capabilities where some limitations like
minimum bandwidth and required granularity are reported as well. The
required attribute <code>vcpus</code> specifies to which vCPUs this
allocation applies. A vCPU can only be member of one
<code>memorytune</code> element allocation. The <code>vcpus</code> specified
by <code>memorytune</code> can be identical to those specified by
<code>cachetune</code>. However they are not allowed to overlap each other.
Supported subelements are:
<dl><dt><code>node</code></dt><dd>
This element controls the allocation of CPU memory bandwidth and has the
following attributes:
<dl><dt><code>id</code></dt><dd>
Host node id from which to allocate memory bandwidth.
</dd><dt><code>bandwidth</code></dt><dd>
The memory bandwidth to allocate from this node. The value by default
is in percentage.
</dd></dl>
</dd></dl>
</dd>
</dl>
<h3>
<a id="elementsMemoryAllocation">Memory Allocation</a>
<a class="headerlink" href="#elementsMemoryAllocation" title="Permalink to this headline">¶</a>
</h3>
<pre>
<domain>
...
<maxMemory slots='16' unit='KiB'>1524288</maxMemory>
<memory unit='KiB'>524288</memory>
<currentMemory unit='KiB'>524288</currentMemory>
...
</domain>
</pre>
<dl>
<dt>
<code>memory</code>
</dt>
<dd>The maximum allocation of memory for the guest at boot time. The
memory allocation includes possible additional memory devices specified
at start or hotplugged later.
The units for this value are determined by the optional
attribute <code>unit</code>, which defaults to "KiB"
(kibibytes, 2<sup>10</sup> or blocks of 1024 bytes). Valid
units are "b" or "bytes" for bytes, "KB" for kilobytes
(10<sup>3</sup> or 1,000 bytes), "k" or "KiB" for kibibytes
(1024 bytes), "MB" for megabytes (10<sup>6</sup> or 1,000,000
bytes), "M" or "MiB" for mebibytes (2<sup>20</sup> or
1,048,576 bytes), "GB" for gigabytes (10<sup>9</sup> or
1,000,000,000 bytes), "G" or "GiB" for gibibytes
(2<sup>30</sup> or 1,073,741,824 bytes), "TB" for terabytes
(10<sup>12</sup> or 1,000,000,000,000 bytes), or "T" or "TiB"
for tebibytes (2<sup>40</sup> or 1,099,511,627,776 bytes).
However, the value will be rounded up to the nearest kibibyte
by libvirt, and may be further rounded to the granularity
supported by the hypervisor. Some hypervisors also enforce a
minimum, such as 4000KiB.
In case <a href="#elementsCPU">NUMA</a> is configured for the guest the
<code>memory</code> element can be omitted.
In the case of crash, optional attribute <code>dumpCore</code>
can be used to control whether the guest memory should be
included in the generated coredump or not (values "on", "off").
<span class="since"><code>unit</code> since 0.9.11</span>,
<span class="since"><code>dumpCore</code> since 0.10.2
(QEMU only)</span></dd>
<dt>
<code>maxMemory</code>
</dt>
<dd>The run time maximum memory allocation of the guest. The initial
memory specified by either the <code><memory></code> element or
the NUMA cell size configuration can be increased by hot-plugging of
memory to the limit specified by this element.
The <code>unit</code> attribute behaves the same as for
<code><memory></code>.
The <code>slots</code> attribute specifies the number of slots
available for adding memory to the guest. The bounds are hypervisor
specific.
Note that due to alignment of the memory chunks added via memory
hotplug the full size allocation specified by this element may be
impossible to achieve.
<span class="since">Since 1.2.14 supported by the QEMU driver.</span>
</dd>
<dt>
<code>currentMemory</code>
</dt>
<dd>The actual allocation of memory for the guest. This value can
be less than the maximum allocation, to allow for ballooning
up the guests memory on the fly. If this is omitted, it defaults
to the same value as the <code>memory</code> element.
The <code>unit</code> attribute behaves the same as
for <code>memory</code>.</dd>
</dl>
<h3>
<a id="elementsMemoryBacking">Memory Backing</a>
<a class="headerlink" href="#elementsMemoryBacking" title="Permalink to this headline">¶</a>
</h3>
<pre>
<domain>
...
<memoryBacking>
<hugepages>
<page size="1" unit="G" nodeset="0-3,5"/>
<page size="2" unit="M" nodeset="4"/>
</hugepages>
<nosharepages/>
<locked/>
<source type="file|anonymous|memfd"/>
<access mode="shared|private"/>
<allocation mode="immediate|ondemand"/>
<discard/>
</memoryBacking>
...
</domain>
</pre>
<p>The optional <code>memoryBacking</code> element may contain several
elements that influence how virtual memory pages are backed by host
pages.</p>
<dl>
<dt>
<code>hugepages</code>
</dt>
<dd>This tells the hypervisor that the guest should have its memory
allocated using hugepages instead of the normal native page size.
<span class="since">Since 1.2.5</span> it's possible to set hugepages
more specifically per numa node. The <code>page</code> element is
introduced. It has one compulsory attribute <code>size</code> which
specifies which hugepages should be used (especially useful on systems
supporting hugepages of different sizes). The default unit for the
<code>size</code> attribute is kilobytes (multiplier of 1024). If you
want to use different unit, use optional <code>unit</code> attribute.
For systems with NUMA, the optional <code>nodeset</code> attribute may
come handy as it ties given guest's NUMA nodes to certain hugepage
sizes. From the example snippet, one gigabyte hugepages are used for
every NUMA node except node number four. For the correct syntax see
<a href="#elementsNUMATuning">this</a>.</dd>
<dt>
<code>nosharepages</code>
</dt>
<dd>Instructs hypervisor to disable shared pages (memory merge, KSM) for
this domain. <span class="since">Since 1.0.6</span></dd>
<dt>
<code>locked</code>
</dt>
<dd>When set and supported by the hypervisor, memory pages belonging
to the domain will be locked in host's memory and the host will not
be allowed to swap them out, which might be required for some
workloads such as real-time. For QEMU/KVM guests, the memory used by
the QEMU process itself will be locked too: unlike guest memory, this
is an amount libvirt has no way of figuring out in advance, so it has
to remove the limit on locked memory altogether. Thus, enabling this
option opens up to a potential security risk: the host will be unable
to reclaim the locked memory back from the guest when it's running out
of memory, which means a malicious guest allocating large amounts of
locked memory could cause a denial-of-service attack on the host.
Because of this, using this option is discouraged unless your workload
demands it; even then, it's highly recommended to set a
<code>hard_limit</code> (see
<a href="#elementsMemoryTuning">memory tuning</a>) on memory allocation
suitable for the specific environment at the same time to mitigate
the risks described above. <span class="since">Since 1.0.6</span></dd>
<dt>
<code>source</code>
</dt>
<dd>Using the <code>type</code> attribute, it's possible to
provide "file" to utilize file memorybacking or keep the
default "anonymous". <span class="since">Since 4.10.0</span>,
you may choose "memfd" backing. (QEMU/KVM only)</dd>
<dt>
<code>access</code>
</dt>
<dd>Using the <code>mode</code> attribute, specify if the memory is
to be "shared" or "private". This can be overridden per numa node by
<code>memAccess</code>.</dd>
<dt>
<code>allocation</code>
</dt>
<dd>Using the <code>mode</code> attribute, specify when to allocate
the memory by supplying either "immediate" or "ondemand".</dd>
<dt>
<code>discard</code>
</dt>
<dd>When set and supported by hypervisor the memory
content is discarded just before guest shuts down (or
when DIMM module is unplugged). Please note that this is
just an optimization and is not guaranteed to work in
all cases (e.g. when hypervisor crashes).
<span class="since">Since 4.4.0</span> (QEMU/KVM only)
</dd>
</dl>
<h3>
<a id="elementsMemoryTuning">Memory Tuning</a>
<a class="headerlink" href="#elementsMemoryTuning" title="Permalink to this headline">¶</a>
</h3>
<pre>
<domain>
...
<memtune>
<hard_limit unit='G'>1</hard_limit>
<soft_limit unit='M'>128</soft_limit>
<swap_hard_limit unit='G'>2</swap_hard_limit>
<min_guarantee unit='bytes'>67108864</min_guarantee>
</memtune>
...
</domain>
</pre>
<dl>
<dt>
<code>memtune</code>
</dt>
<dd> The optional <code>memtune</code> element provides details
regarding the memory tunable parameters for the domain. If this is
omitted, it defaults to the OS provided defaults. For QEMU/KVM, the
parameters are applied to the QEMU process as a whole. Thus, when
counting them, one needs to add up guest RAM, guest video RAM, and
some memory overhead of QEMU itself. The last piece is hard to
determine so one needs guess and try. For each tunable, it
is possible to designate which unit the number is in on
input, using the same values as
for <code><memory></code>. For backwards
compatibility, output is always in
KiB. <span class="since"><code>unit</code>
since 0.9.11</span>
Possible values for all *_limit parameters are in range from 0 to
VIR_DOMAIN_MEMORY_PARAM_UNLIMITED.</dd>
<dt>
<code>hard_limit</code>
</dt>
<dd> The optional <code>hard_limit</code> element is the maximum memory
the guest can use. The units for this value are kibibytes (i.e. blocks
of 1024 bytes). Users of QEMU and KVM are strongly advised not to set
this limit as domain may get killed by the kernel if the guess is too
low, and determining the memory needed for a process to run is an
<a href="http://en.wikipedia.org/wiki/Undecidable_problem">
undecidable problem</a>; that said, if you already set
<code>locked</code> in
<a href="#elementsMemoryBacking">memory backing</a> because your
workload demands it, you'll have to take into account the specifics of
your deployment and figure out a value for <code>hard_limit</code> that
is large enough to support the memory requirements of your guest, but
small enough to protect your host against a malicious guest locking all
memory.</dd>
<dt>
<code>soft_limit</code>
</dt>
<dd> The optional <code>soft_limit</code> element is the memory limit to
enforce during memory contention. The units for this value are
kibibytes (i.e. blocks of 1024 bytes)</dd>
<dt>
<code>swap_hard_limit</code>
</dt>
<dd> The optional <code>swap_hard_limit</code> element is the maximum
memory plus swap the guest can use. The units for this value are
kibibytes (i.e. blocks of 1024 bytes). This has to be more than
hard_limit value provided</dd>
<dt>
<code>min_guarantee</code>
</dt>
<dd> The optional <code>min_guarantee</code> element is the guaranteed
minimum memory allocation for the guest. The units for this value are
kibibytes (i.e. blocks of 1024 bytes). This element is only supported
by VMware ESX and OpenVZ drivers.</dd>
</dl>
<h3>
<a id="elementsNUMATuning">NUMA Node Tuning</a>
<a class="headerlink" href="#elementsNUMATuning" title="Permalink to this headline">¶</a>
</h3>
<pre>
<domain>
...
<numatune>
<memory mode="strict" nodeset="1-4,^3"/>
<memnode cellid="0" mode="strict" nodeset="1"/>
<memnode cellid="2" mode="preferred" nodeset="2"/>
</numatune>
...
</domain>
</pre>
<dl>
<dt>
<code>numatune</code>
</dt>
<dd>
The optional <code>numatune</code> element provides details of
how to tune the performance of a NUMA host via controlling NUMA policy
for domain process. NB, only supported by QEMU driver.
<span class="since">Since 0.9.3</span>
</dd>
<dt>
<code>memory</code>
</dt>
<dd>
The optional <code>memory</code> element specifies how to allocate memory
for the domain process on a NUMA host. It contains several optional
attributes. Attribute <code>mode</code> is either 'interleave',
'strict', or 'preferred', defaults to 'strict'. Attribute
<code>nodeset</code> specifies the NUMA nodes, using the same syntax as
attribute <code>cpuset</code> of element <code>vcpu</code>. Attribute
<code>placement</code> (<span class="since">since 0.9.12</span>) can be
used to indicate the memory placement mode for domain process, its value
can be either "static" or "auto", defaults to <code>placement</code> of
<code>vcpu</code>, or "static" if <code>nodeset</code> is specified.
"auto" indicates the domain process will only allocate memory from the
advisory nodeset returned from querying numad, and the value of attribute
<code>nodeset</code> will be ignored if it's specified.
If <code>placement</code> of <code>vcpu</code> is 'auto', and
<code>numatune</code> is not specified, a default <code>numatune</code>
with <code>placement</code> 'auto' and <code>mode</code> 'strict' will
be added implicitly.
<span class="since">Since 0.9.3</span>
</dd>
<dt>
<code>memnode</code>
</dt>
<dd>
Optional <code>memnode</code> elements can specify memory allocation
policies per each guest NUMA node. For those nodes having no
corresponding <code>memnode</code> element, the default from
element <code>memory</code> will be used. Attribute <code>cellid</code>
addresses guest NUMA node for which the settings are applied.
Attributes <code>mode</code> and <code>nodeset</code> have the same
meaning and syntax as in <code>memory</code> element.
This setting is not compatible with automatic placement.
<span class="since">QEMU Since 1.2.7</span>
</dd>
</dl>
<h3>
<a id="elementsBlockTuning">Block I/O Tuning</a>
<a class="headerlink" href="#elementsBlockTuning" title="Permalink to this headline">¶</a>
</h3>
<pre>
<domain>
...
<blkiotune>
<weight>800</weight>
<device>
<path>/dev/sda</path>
<weight>1000</weight>
</device>
<device>
<path>/dev/sdb</path>
<weight>500</weight>
<read_bytes_sec>10000</read_bytes_sec>
<write_bytes_sec>10000</write_bytes_sec>
<read_iops_sec>20000</read_iops_sec>
<write_iops_sec>20000</write_iops_sec>
</device>
</blkiotune>
...
</domain>
</pre>
<dl>
<dt>
<code>blkiotune</code>
</dt>
<dd> The optional <code>blkiotune</code> element provides the ability
to tune Blkio cgroup tunable parameters for the domain. If this is
omitted, it defaults to the OS provided
defaults. <span class="since">Since 0.8.8</span></dd>
<dt>
<code>weight</code>
</dt>
<dd> The optional <code>weight</code> element is the overall I/O
weight of the guest. The value should be in the range [100,
1000]. After kernel 2.6.39, the value could be in the
range [10, 1000].</dd>
<dt>
<code>device</code>
</dt>
<dd>The domain may have multiple <code>device</code> elements
that further tune the weights for each host block device in
use by the domain. Note that
multiple <a href="#elementsDisks">guest disks</a> can share a
single host block device, if they are backed by files within
the same host file system, which is why this tuning parameter
is at the global domain level rather than associated with each
guest disk device (contrast this to
the <a href="#elementsDisks"><code><iotune></code></a>
element which can apply to an
individual <code><disk></code>).
Each <code>device</code> element has two
mandatory sub-elements, <code>path</code> describing the
absolute path of the device, and <code>weight</code> giving
the relative weight of that device, in the range [100,
1000]. After kernel 2.6.39, the value could be in the
range [10, 1000]. <span class="since">Since 0.9.8</span><br/>
Additionally, the following optional sub-elements can be used:
<dl><dt><code>read_bytes_sec</code></dt><dd>Read throughput limit in bytes per second.
<span class="since">Since 1.2.2</span></dd><dt><code>write_bytes_sec</code></dt><dd>Write throughput limit in bytes per second.
<span class="since">Since 1.2.2</span></dd><dt><code>read_iops_sec</code></dt><dd>Read I/O operations per second limit.
<span class="since">Since 1.2.2</span></dd><dt><code>write_iops_sec</code></dt><dd>Write I/O operations per second limit.
<span class="since">Since 1.2.2</span></dd></dl></dd>
</dl>
<h3>
<a id="resPartition">Resource partitioning</a>
<a class="headerlink" href="#resPartition" title="Permalink to this headline">¶</a>
</h3>
<p>
Hypervisors may allow for virtual machines to be placed into
resource partitions, potentially with nesting of said partitions.
The <code>resource</code> element groups together configuration
related to resource partitioning. It currently supports a child
element <code>partition</code> whose content defines the absolute path
of the resource partition in which to place the domain. If no
partition is listed, then the domain will be placed in a default
partition. It is the responsibility of the app/admin to ensure
that the partition exists prior to starting the guest. Only the
(hypervisor specific) default partition can be assumed to exist
by default.
</p>
<pre>
...
<resource>
<partition>/virtualmachines/production</partition>
</resource>
...
</pre>
<p>
Resource partitions are currently supported by the QEMU and
LXC drivers, which map partition paths to cgroups directories,
in all mounted controllers. <span class="since">Since 1.0.5</span>
</p>
<h3>
<a id="elementsCPU">CPU model and topology</a>
<a class="headerlink" href="#elementsCPU" title="Permalink to this headline">¶</a>
</h3>
<p>
Requirements for CPU model, its features and topology can be specified
using the following collection of elements.
<span class="since">Since 0.7.5</span>
</p>
<pre>
...
<cpu match='exact'>
<model fallback='allow'>core2duo</model>
<vendor>Intel</vendor>
<topology sockets='1' cores='2' threads='1'/>
<cache level='3' mode='emulate'/>
<feature policy='disable' name='lahf_lm'/>
</cpu>
...</pre>
<pre>
<cpu mode='host-model'>
<model fallback='forbid'/>
<topology sockets='1' cores='2' threads='1'/>
</cpu>
...</pre>
<pre>
<cpu mode='host-passthrough'>
<cache mode='passthrough'/>
<feature policy='disable' name='lahf_lm'/>
...</pre>
<p>
In case no restrictions need to be put on CPU model and its features, a
simpler <code>cpu</code> element can be used.
<span class="since">Since 0.7.6</span>
</p>
<pre>
...
<cpu>
<topology sockets='1' cores='2' threads='1'/>
</cpu>
...</pre>
<dl>
<dt>
<code>cpu</code>
</dt>
<dd>The <code>cpu</code> element is the main container for describing
guest CPU requirements. Its <code>match</code> attribute specifies how
strictly the virtual CPU provided to the guest matches these
requirements. <span class="since">Since 0.7.6</span> the
<code>match</code> attribute can be omitted if <code>topology</code>
is the only element within <code>cpu</code>. Possible values for the
<code>match</code> attribute are:
<dl><dt><code>minimum</code></dt><dd>The specified CPU model and features describes the minimum
requested CPU. A better CPU will be provided to the guest if it
is possible with the requested hypervisor on the current host.
This is a constrained <code>host-model</code> mode; the domain
will not be created if the provided virtual CPU does not meet
the requirements.</dd><dt><code>exact</code></dt><dd>The virtual CPU provided to the guest should exactly match the
specification. If such CPU is not supported, libvirt will refuse
to start the domain.</dd><dt><code>strict</code></dt><dd>The domain will not be created unless the host CPU exactly
matches the specification. This is not very useful in practice
and should only be used if there is a real reason.</dd></dl>
<span class="since">Since 0.8.5</span> the <code>match</code>
attribute can be omitted and will default to <code>exact</code>.
Sometimes the hypervisor is not able to create a virtual CPU exactly
matching the specification passed by libvirt.
<span class="since">Since 3.2.0</span>, an optional <code>check</code>
attribute can be used to request a specific way of checking whether
the virtual CPU matches the specification. It is usually safe to omit
this attribute when starting a domain and stick with the default
value. Once the domain starts, libvirt will automatically change the
<code>check</code> attribute to the best supported value to ensure the
virtual CPU does not change when the domain is migrated to another
host. The following values can be used:
<dl><dt><code>none</code></dt><dd>Libvirt does no checking and it is up to the hypervisor to
refuse to start the domain if it cannot provide the requested CPU.
With QEMU this means no checking is done at all since the default
behavior of QEMU is to emit warnings, but start the domain anyway.
</dd><dt><code>partial</code></dt><dd>Libvirt will check the guest CPU specification before starting
a domain, but the rest is left on the hypervisor. It can still
provide a different virtual CPU.</dd><dt><code>full</code></dt><dd>The virtual CPU created by the hypervisor will be checked
against the CPU specification and the domain will not be started
unless the two CPUs match.</dd></dl>
<span class="since">Since 0.9.10</span>, an optional <code>mode</code>
attribute may be used to make it easier to configure a guest CPU to be
as close to host CPU as possible. Possible values for the
<code>mode</code> attribute are:
<dl><dt><code>custom</code></dt><dd>In this mode, the <code>cpu</code> element describes the CPU
that should be presented to the guest. This is the default when no
<code>mode</code> attribute is specified. This mode makes it so that
a persistent guest will see the same hardware no matter what host
the guest is booted on.</dd><dt><code>host-model</code></dt><dd>The <code>host-model</code> mode is essentially a shortcut to
copying host CPU definition from capabilities XML into domain XML.
Since the CPU definition is copied just before starting a domain,
exactly the same XML can be used on different hosts while still
providing the best guest CPU each host supports. The
<code>match</code> attribute can't be used in this mode. Specifying
CPU model is not supported either, but <code>model</code>'s
<code>fallback</code> attribute may still be used. Using the
<code>feature</code> element, specific flags may be enabled or
disabled specifically in addition to the host model. This may be
used to fine tune features that can be emulated.
<span class="since">(Since 1.1.1)</span>.
Libvirt does not model every aspect of each CPU so
the guest CPU will not match the host CPU exactly. On the other
hand, the ABI provided to the guest is reproducible. During
migration, complete CPU model definition is transferred to the
destination host so the migrated guest will see exactly the same CPU
model even if the destination host contains more capable CPUs for
the running instance of the guest; but shutting down and restarting
the guest may present different hardware to the guest according to
the capabilities of the new host. Prior to libvirt 3.2.0 and QEMU
2.9.0 detection of the host CPU model via QEMU is not supported.
Thus the CPU configuration created using <code>host-model</code>
may not work as expected.
<span class="since">Since 3.2.0 and QEMU 2.9.0</span> this mode
works the way it was designed and it is indicated by the
<code>fallback</code> attribute set to <code>forbid</code> in the
host-model CPU definition advertised in
<a href="formatdomaincaps.html#elementsCPU">domain capabilities XML</a>.
When <code>fallback</code> attribute is set to <code>allow</code>
in the domain capabilities XML, it is recommended to use
<code>custom</code> mode with just the CPU model from the host
capabilities XML. <span class="since">Since 1.2.11</span> PowerISA
allows processors to run VMs in binary compatibility mode supporting
an older version of ISA. Libvirt on PowerPC architecture uses the
<code>host-model</code> to signify a guest mode CPU running in
binary compatibility mode. Example:
When a user needs a power7 VM to run in compatibility mode
on a Power8 host, this can be described in XML as follows :
<pre>
<cpu mode='host-model'>
<model>power7</model>
</cpu>
...</pre>
</dd><dt><code>host-passthrough</code></dt><dd>With this mode, the CPU visible to the guest should be exactly
the same as the host CPU even in the aspects that libvirt does not
understand. Though the downside of this mode is that the guest
environment cannot be reproduced on different hardware. Thus, if you
hit any bugs, you are on your own. Further details of that CPU can
be changed using <code>feature</code> elements. Migration of a guest
using host-passthrough is dangerous if the source and destination
hosts are not identical in both hardware and configuration. If such
a migration is attempted then the guest may hang or crash upon
resuming execution on the destination host.</dd></dl>
Both <code>host-model</code> and <code>host-passthrough</code> modes
make sense when a domain can run directly on the host CPUs (for
example, domains with type <code>kvm</code>). The actual host CPU is
irrelevant for domains with emulated virtual CPUs (such as domains with
type <code>qemu</code>). However, for backward compatibility
<code>host-model</code> may be implemented even for domains running on
emulated CPUs in which case the best CPU the hypervisor is able to
emulate may be used rather then trying to mimic the host CPU model.
</dd>
<dt>
<code>model</code>
</dt>
<dd>The content of the <code>model</code> element specifies CPU model
requested by the guest. The list of available CPU models and their
definition can be found in <code>cpu_map.xml</code> file installed
in libvirt's data directory. If a hypervisor is not able to use the
exact CPU model, libvirt automatically falls back to a closest model
supported by the hypervisor while maintaining the list of CPU
features. <span class="since">Since 0.9.10</span>, an optional
<code>fallback</code> attribute can be used to forbid this behavior,
in which case an attempt to start a domain requesting an unsupported
CPU model will fail. Supported values for <code>fallback</code>
attribute are: <code>allow</code> (this is the default), and
<code>forbid</code>. The optional <code>vendor_id</code> attribute
(<span class="since">Since 0.10.0</span>) can be used to set the
vendor id seen by the guest. It must be exactly 12 characters long.
If not set the vendor id of the host is used. Typical possible
values are "AuthenticAMD" and "GenuineIntel".</dd>
<dt>
<code>vendor</code>
</dt>
<dd><span class="since">Since 0.8.3</span> the content of the
<code>vendor</code> element specifies CPU vendor requested by the
guest. If this element is missing, the guest can be run on a CPU
matching given features regardless on its vendor. The list of
supported vendors can be found in <code>cpu_map.xml</code>.</dd>
<dt>
<code>topology</code>
</dt>
<dd>The <code>topology</code> element specifies requested topology of
virtual CPU provided to the guest. Three non-zero values have to be
given for <code>sockets</code>, <code>cores</code>, and
<code>threads</code>: total number of CPU sockets, number of cores per
socket, and number of threads per core, respectively. Hypervisors may
require that the maximum number of vCPUs specified by the
<code>cpus</code> element equals to the number of vcpus resulting
from the topology.</dd>
<dt>
<code>feature</code>
</dt>
<dd>The <code>cpu</code> element can contain zero or more
<code>elements</code> used to fine-tune features provided by the
selected CPU model. The list of known feature names can be found in
the same file as CPU models. The meaning of each <code>feature</code>
element depends on its <code>policy</code> attribute, which has to be
set to one of the following values:
<dl><dt><code>force</code></dt><dd>The virtual CPU will claim the feature is supported regardless
of it being supported by host CPU.</dd><dt><code>require</code></dt><dd>Guest creation will fail unless the feature is supported by the
host CPU or the hypervisor is able to emulate it.</dd><dt><code>optional</code></dt><dd>The feature will be supported by virtual CPU if and only if it
is supported by host CPU.</dd><dt><code>disable</code></dt><dd>The feature will not be supported by virtual CPU.</dd><dt><code>forbid</code></dt><dd>Guest creation will fail if the feature is supported by host
CPU.</dd></dl>
<span class="since">Since 0.8.5</span> the <code>policy</code>
attribute can be omitted and will default to <code>require</code>.
<p> Individual CPU feature names are specified as part of the
<code>name</code> attribute. For example, to explicitly specify
the 'pcid' feature with Intel IvyBridge CPU model:
</p>
<pre>
...
<cpu match='exact'>
<model fallback='forbid'>IvyBridge</model>
<vendor>Intel</vendor>
<feature policy='require' name='pcid'/>
</cpu>
...</pre>
</dd>
<dt>
<code>cache</code>
</dt>
<dd><span class="since">Since 3.3.0</span> the <code>cache</code>
element describes the virtual CPU cache. If the element is missing,
the hypervisor will use a sensible default.
<dl><dt><code>level</code></dt><dd>This optional attribute specifies which cache level is described
by the element. Missing attribute means the element describes all
CPU cache levels at once. Mixing <code>cache</code> elements with
the <code>level</code> attribute set and those without the
attribute is forbidden.</dd><dt><code>mode</code></dt><dd>
The following values are supported:
<dl><dt><code>emulate</code></dt><dd>The hypervisor will provide a fake CPU cache data.</dd><dt><code>passthrough</code></dt><dd>The real CPU cache data reported by the host CPU will be
passed through to the virtual CPU.</dd><dt><code>disable</code></dt><dd>The virtual CPU will report no CPU cache of the specified
level (or no cache at all if the <code>level</code> attribute
is missing).</dd></dl>
</dd></dl>
</dd>
</dl>
<p>
Guest NUMA topology can be specified using the <code>numa</code> element.
<span class="since">Since 0.9.8</span>
</p>
<pre>
...
<cpu>
...
<numa>
<cell id='0' cpus='0-3' memory='512000' unit='KiB' discard='yes'/>
<cell id='1' cpus='4-7' memory='512000' unit='KiB' memAccess='shared'/>
</numa>
...
</cpu>
...</pre>
<p>
Each <code>cell</code> element specifies a NUMA cell or a NUMA node.
<code>cpus</code> specifies the CPU or range of CPUs that are
part of the node. <code>memory</code> specifies the node memory
in kibibytes (i.e. blocks of 1024 bytes).
<span class="since">Since 1.2.11</span> one can use an additional <a href="#elementsMemoryAllocation"><code>unit</code></a> attribute to
define units in which <code>memory</code> is specified.
<span class="since">Since 1.2.7</span> all cells should
have <code>id</code> attribute in case referring to some cell is
necessary in the code, otherwise the cells are
assigned <code>id</code>s in the increasing order starting from
0. Mixing cells with and without the <code>id</code> attribute
is not recommended as it may result in unwanted behaviour.
<span class="since">Since 1.2.9</span> the optional attribute
<code>memAccess</code> can control whether the memory is to be
mapped as "shared" or "private". This is valid only for
hugepages-backed memory and nvdimm modules.
Each <code>cell</code> element can have an optional
<code>discard</code> attribute which fine tunes the discard
feature for given numa node as described under
<a href="#elementsMemoryBacking">Memory Backing</a>.
Accepted values are <code>yes</code> and <code>no</code>.
<span class="since">Since 4.4.0</span>
</p>
<p>
This guest NUMA specification is currently available only for
QEMU/KVM and Xen.
</p>
<p>
A NUMA hardware architecture supports the notion of distances
between NUMA cells. <span class="since">Since 3.10.0</span> it
is possible to define the distance between NUMA cells using the
<code>distances</code> element within a NUMA <code>cell</code>
description. The <code>sibling</code> sub-element is used to
specify the distance value between sibling NUMA cells. For more
details, see the chapter explaining the system's SLIT (System
Locality Information Table) within the ACPI (Advanced
Configuration and Power Interface) specification.
</p>
<pre>
...
<cpu>
...
<numa>
<cell id='0' cpus='0,4-7' memory='512000' unit='KiB'>
<distances>
<sibling id='0' value='10'/>
<sibling id='1' value='21'/>
<sibling id='2' value='31'/>
<sibling id='3' value='41'/>
</distances>
</cell>
<cell id='1' cpus='1,8-10,12-15' memory='512000' unit='KiB' memAccess='shared'>
<distances>
<sibling id='0' value='21'/>
<sibling id='1' value='10'/>
<sibling id='2' value='21'/>
<sibling id='3' value='31'/>
</distances>
</cell>
<cell id='2' cpus='2,11' memory='512000' unit='KiB' memAccess='shared'>
<distances>
<sibling id='0' value='31'/>
<sibling id='1' value='21'/>
<sibling id='2' value='10'/>
<sibling id='3' value='21'/>
</distances>
</cell>
<cell id='3' cpus='3' memory='512000' unit='KiB'>
<distances>
<sibling id='0' value='41'/>
<sibling id='1' value='31'/>
<sibling id='2' value='21'/>
<sibling id='3' value='10'/>
</distances>
</cell>
</numa>
...
</cpu>
...</pre>
<p>
Describing distances between NUMA cells is currently only supported
by Xen and QEMU. If no <code>distances</code> are given to describe
the SLIT data between different cells, it will default to a scheme
using 10 for local and 20 for remote distances.
</p>
<h3>
<a id="elementsEvents">Events configuration</a>
<a class="headerlink" href="#elementsEvents" title="Permalink to this headline">¶</a>
</h3>
<p>
It is sometimes necessary to override the default actions taken
on various events. Not all hypervisors support all events and actions.
The actions may be taken as a result of calls to libvirt APIs
<a href="html/libvirt-libvirt-domain.html#virDomainReboot"><code>virDomainReboot</code></a>,
<a href="html/libvirt-libvirt-domain.html#virDomainShutdown"><code>virDomainShutdown</code></a>,
or
<a href="html/libvirt-libvirt-domain.html#virDomainShutdownFlags"><code>virDomainShutdownFlags</code></a>.
Using <code>virsh reboot</code> or <code>virsh shutdown</code> would
also trigger the event.
</p>
<pre>
...
<on_poweroff>destroy</on_poweroff>
<on_reboot>restart</on_reboot>
<on_crash>restart</on_crash>
<on_lockfailure>poweroff</on_lockfailure>
...</pre>
<p>
The following collections of elements allow the actions to be
specified when a guest OS triggers a lifecycle operation. A
common use case is to force a reboot to be treated as a poweroff
when doing the initial OS installation. This allows the VM to be
re-configured for the first post-install bootup.
</p>
<dl>
<dt>
<code>on_poweroff</code>
</dt>
<dd>The content of this element specifies the action to take when
the guest requests a poweroff.</dd>
<dt>
<code>on_reboot</code>
</dt>
<dd>The content of this element specifies the action to take when
the guest requests a reboot.</dd>
<dt>
<code>on_crash</code>
</dt>
<dd>The content of this element specifies the action to take when
the guest crashes.</dd>
</dl>
<p>
Each of these states allow for the same four possible actions.
</p>
<dl>
<dt>
<code>destroy</code>
</dt>
<dd>The domain will be terminated completely and all resources
released.</dd>
<dt>
<code>restart</code>
</dt>
<dd>The domain will be terminated and then restarted with
the same configuration.</dd>
<dt>
<code>preserve</code>
</dt>
<dd>The domain will be terminated and its resource preserved
to allow analysis.</dd>
<dt>
<code>rename-restart</code>
</dt>
<dd>The domain will be terminated and then restarted with
a new name.</dd>
</dl>
<p>
QEMU/KVM supports the <code>on_poweroff</code> and <code>on_reboot</code>
events handling the <code>destroy</code> and <code>restart</code> actions.
The <code>preserve</code> action for an <code>on_reboot</code> event
is treated as a <code>destroy</code> and the <code>rename-restart</code>
action for an <code>on_poweroff</code> event is treated as a
<code>restart</code> event.
</p>
<p>
The <code>on_crash</code> event supports these additional
actions <span class="since">since 0.8.4</span>.
</p>
<dl>
<dt>
<code>coredump-destroy</code>
</dt>
<dd>The crashed domain's core will be dumped, and then the
domain will be terminated completely and all resources
released</dd>
<dt>
<code>coredump-restart</code>
</dt>
<dd>The crashed domain's core will be dumped, and then the
domain will be restarted with the same configuration</dd>
</dl>
<p><span class="since">Since 3.9.0</span>, the lifecycle events can
be configured via the
<a href="html/libvirt-libvirt-domain.html#virDomainSetLifecycleAction"><code>virDomainSetLifecycleAction</code></a> API.
</p>
<p>
The <code>on_lockfailure</code> element (<span class="since">since
1.0.0</span>) may be used to configure what action should be
taken when a lock manager loses resource locks. The following
actions are recognized by libvirt, although not all of them need
to be supported by individual lock managers. When no action is
specified, each lock manager will take its default action.
</p>
<dl>
<dt>
<code>poweroff</code>
</dt>
<dd>The domain will be forcefully powered off.</dd>
<dt>
<code>restart</code>
</dt>
<dd>The domain will be powered off and started up again to
reacquire its locks.</dd>
<dt>
<code>pause</code>
</dt>
<dd>The domain will be paused so that it can be manually resumed
when lock issues are solved.</dd>
<dt>
<code>ignore</code>
</dt>
<dd>Keep the domain running as if nothing happened.</dd>
</dl>
<h3>
<a id="elementsPowerManagement">Power Management</a>
<a class="headerlink" href="#elementsPowerManagement" title="Permalink to this headline">¶</a>
</h3>
<p><span class="since">Since 0.10.2</span> it is possible to
forcibly enable or disable BIOS advertisements to the guest
OS. (NB: Only qemu driver support)
</p>
<pre>
...
<pm>
<suspend-to-disk enabled='no'/>
<suspend-to-mem enabled='yes'/>
</pm>
...</pre>
<dl>
<dt>
<code>pm</code>
</dt>
<dd>These elements enable ('yes') or disable ('no') BIOS support
for S3 (suspend-to-mem) and S4 (suspend-to-disk) ACPI sleep
states. If nothing is specified, then the hypervisor will be
left with its default value.<br/>
Note: This setting cannot prevent the guest OS from performing
a suspend as the guest OS itself can choose to circumvent the
unavailability of the sleep states (e.g. S4 by turning off
completely).</dd>
</dl>
<h3>
<a id="elementsFeatures">Hypervisor features</a>
<a class="headerlink" href="#elementsFeatures" title="Permalink to this headline">¶</a>
</h3>
<p>
Hypervisors may allow certain CPU / machine features to be
toggled on/off.
</p>
<pre>
...
<features>
<pae/>
<acpi/>
<apic/>
<hap/>
<privnet/>
<hyperv>
<relaxed state='on'/>
<vapic state='on'/>
<spinlocks state='on' retries='4096'/>
<vpindex state='on'/>
<runtime state='on'/>
<synic state='on'/>
<reset state='on'/>
<vendor_id state='on' value='KVM Hv'/>
<frequencies state='on'/>
<reenlightenment state='on'/>
<tlbflush state='on'/>
<ipi state='on'/>
<evmcs state='on'/>
</hyperv>
<kvm>
<hidden state='on'/>
</kvm>
<pvspinlock state='on'/>
<gic version='2'/>
<ioapic driver='qemu'/>
<hpt resizing='required'>
<maxpagesize unit='MiB'>16</maxpagesize>
</hpt>
<vmcoreinfo state='on'/>
<smm state='on'>
<tseg unit='MiB'>48</tseg>
</smm>
<htm state='on'/>
</features>
...</pre>
<p>
All features are listed within the <code>features</code>
element, omitting a togglable feature tag turns it off.
The available features can be found by asking
for the <a href="formatcaps.html">capabilities XML</a> and
<a href="formatdomaincaps.html">domain capabilities XML</a>,
but a common set for fully virtualized domains are:
</p>
<dl>
<dt>
<code>pae</code>
</dt>
<dd>Physical address extension mode allows 32-bit guests
to address more than 4 GB of memory.</dd>
<dt>
<code>acpi</code>
</dt>
<dd>ACPI is useful for power management, for example, with
KVM guests it is required for graceful shutdown to work.
</dd>
<dt>
<code>apic</code>
</dt>
<dd>APIC allows the use of programmable IRQ
management. <span class="since">Since 0.10.2 (QEMU only)</span> there is
an optional attribute <code>eoi</code> with values <code>on</code>
and <code>off</code> which toggles the availability of EOI (End of
Interrupt) for the guest.
</dd>
<dt>
<code>hap</code>
</dt>
<dd>Depending on the <code>state</code> attribute (values <code>on</code>,
<code>off</code>) enable or disable use of Hardware Assisted Paging.
The default is <code>on</code> if the hypervisor detects availability
of Hardware Assisted Paging.
</dd>
<dt>
<code>viridian</code>
</dt>
<dd>Enable Viridian hypervisor extensions for paravirtualizing
guest operating systems
</dd>
<dt>
<code>privnet</code>
</dt>
<dd>Always create a private network namespace. This is
automatically set if any interface devices are defined.
This feature is only relevant for container based
virtualization drivers, such as LXC.
</dd>
<dt>
<code>hyperv</code>
</dt>
<dd>Enable various features improving behavior of guests
running Microsoft Windows.
<table class="top_table"><tr><th>Feature</th><th>Description</th><th>Value</th><th>Since</th></tr><tr><td>relaxed</td><td>Relax constraints on timers</td><td>on, off</td><td><span class="since">1.0.0 (QEMU 2.0)</span></td></tr><tr><td>vapic</td><td>Enable virtual APIC</td><td>on, off</td><td><span class="since">1.1.0 (QEMU 2.0)</span></td></tr><tr><td>spinlocks</td><td>Enable spinlock support</td><td>on, off; retries - at least 4095</td><td><span class="since">1.1.0 (QEMU 2.0)</span></td></tr><tr><td>vpindex</td><td>Virtual processor index</td><td>on, off</td><td><span class="since">1.3.3 (QEMU 2.5)</span></td></tr><tr><td>runtime</td><td>Processor time spent on running guest code and on behalf of guest code</td><td>on, off</td><td><span class="since">1.3.3 (QEMU 2.5)</span></td></tr><tr><td>synic</td><td>Enable Synthetic Interrupt Controller (SyNIC)</td><td>on, off</td><td><span class="since">1.3.3 (QEMU 2.6)</span></td></tr><tr><td>stimer</td><td>Enable SyNIC timers</td><td>on, off</td><td><span class="since">1.3.3 (QEMU 2.6)</span></td></tr><tr><td>reset</td><td>Enable hypervisor reset</td><td>on, off</td><td><span class="since">1.3.3 (QEMU 2.5)</span></td></tr><tr><td>vendor_id</td><td>Set hypervisor vendor id</td><td>on, off; value - string, up to 12 characters</td><td><span class="since">1.3.3 (QEMU 2.5)</span></td></tr><tr><td>frequencies</td><td>Expose frequency MSRs</td><td>on, off</td><td><span class="since">4.7.0 (QEMU 2.12)</span></td></tr><tr><td>reenlightenment</td><td>Enable re-enlightenment notification on migration</td><td>on, off</td><td><span class="since">4.7.0 (QEMU 3.0)</span></td></tr><tr><td>tlbflush</td><td>Enable PV TLB flush support</td><td>on, off</td><td><span class="since">4.7.0 (QEMU 3.0)</span></td></tr><tr><td>ipi</td><td>Enable PV IPI support</td><td>on, off</td><td><span class="since">4.10.0 (QEMU 3.1)</span></td></tr><tr><td>evmcs</td><td>Enable Enlightened VMCS</td><td>on, off</td><td><span class="since">4.10.0 (QEMU 3.1)</span></td></tr></table>
</dd>
<dt>
<code>pvspinlock</code>
</dt>
<dd>Notify the guest that the host supports paravirtual spinlocks
for example by exposing the pvticketlocks mechanism. This feature
can be explicitly disabled by using <code>state='off'</code>
attribute.
</dd>
<dt>
<code>kvm</code>
</dt>
<dd>Various features to change the behavior of the KVM hypervisor.
<table class="top_table"><tr><th>Feature</th><th>Description</th><th>Value</th><th>Since</th></tr><tr><td>hidden</td><td>Hide the KVM hypervisor from standard MSR based discovery</td><td>on, off</td><td><span class="since">1.2.8 (QEMU 2.1.0)</span></td></tr></table>
</dd>
<dt>
<code>pmu</code>
</dt>
<dd>Depending on the <code>state</code> attribute (values <code>on</code>,
<code>off</code>, default <code>on</code>) enable or disable the
performance monitoring unit for the guest.
<span class="since">Since 1.2.12</span>
</dd>
<dt>
<code>vmport</code>
</dt>
<dd>Depending on the <code>state</code> attribute (values <code>on</code>,
<code>off</code>, default <code>on</code>) enable or disable
the emulation of VMware IO port, for vmmouse etc.
<span class="since">Since 1.2.16</span>
</dd>
<dt>
<code>gic</code>
</dt>
<dd>Enable for architectures using a General Interrupt
Controller instead of APIC in order to handle interrupts.
For example, the 'aarch64' architecture uses
<code>gic</code> instead of <code>apic</code>. The optional
attribute <code>version</code> specifies the GIC version;
however, it may not be supported by all hypervisors. Accepted
values are <code>2</code>, <code>3</code> and <code>host</code>.
<span class="since">Since 1.2.16</span>
</dd>
<dt>
<code>smm</code>
</dt>
<dd>
<p>
Depending on the <code>state</code> attribute (values <code>on</code>,
<code>off</code>, default <code>on</code>) enable or disable
System Management Mode.
<span class="since">Since 2.1.0</span>
</p>
<p> Optional sub-element <code>tseg</code> can be used to specify
the amount of memory dedicated to SMM's extended TSEG. That offers a
fourth option size apart from the existing ones (1 MiB, 2 MiB and 8
MiB) that the guest OS (or rather loader) can choose from. The size
can be specified as a value of that element, optional attribute
<code>unit</code> can be used to specify the unit of the
aforementioned value (defaults to 'MiB'). If set to 0 the extended
size is not advertised and only the default ones (see above) are
available.
</p>
<p>
<b>If the VM is booting you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</p>
<p>
This value is configurable due to the fact that the calculation cannot
be done right with the guarantee that it will work correctly. In
QEMU, the user-configurable extended TSEG feature was unavailable up
to and including <code>pc-q35-2.9</code>. Starting with
<code>pc-q35-2.10</code> the feature is available, with default size
16 MiB. That should suffice for up to roughly 272 vCPUs, 5 GiB guest
RAM in total, no hotplug memory range, and 32 GiB of 64-bit PCI MMIO
aperture. Or for 48 vCPUs, with 1TB of guest RAM, no hotplug DIMM
range, and 32GB of 64-bit PCI MMIO aperture. The values may also vary
based on the loader the VM is using.
</p>
<p>
Additional size might be needed for significantly higher vCPU counts
or increased address space (that can be memory, maxMemory, 64-bit PCI
MMIO aperture size; roughly 8 MiB of TSEG per 1 TiB of address space)
which can also be rounded up.
</p>
<p>
Due to the nature of this setting being similar to "how much RAM
should the guest have" users are advised to either consult the
documentation of the guest OS or loader (if there is any), or test
this by trial-and-error changing the value until the VM boots
successfully. Yet another guiding value for users might be the fact
that 48 MiB should be enough for pretty large guests (240 vCPUs and
4TB guest RAM), but it is on purpose not set as default as 48 MiB of
unavailable RAM might be too much for small guests (e.g. with 512 MiB
of RAM).
</p>
<p>
See <a href="#elementsMemoryAllocation">Memory Allocation</a>
for more details about the <code>unit</code> attribute.
<span class="since">Since 4.5.0</span> (QEMU only)
</p>
</dd>
<dt>
<code>ioapic</code>
</dt>
<dd>Tune the I/O APIC. Possible values for the
<code>driver</code> attribute are:
<code>kvm</code> (default for KVM domains)
and <code>qemu</code> which puts I/O APIC in userspace
which is also known as a split I/O APIC mode.
<span class="since">Since 3.4.0</span> (QEMU/KVM only)
</dd>
<dt>
<code>hpt</code>
</dt>
<dd>Configure the HPT (Hash Page Table) of a pSeries guest. Possible
values for the <code>resizing</code> attribute are
<code>enabled</code>, which causes HPT resizing to be enabled if
both the guest and the host support it; <code>disabled</code>, which
causes HPT resizing to be disabled regardless of guest and host
support; and <code>required</code>, which prevents the guest from
starting unless both the guest and the host support HPT resizing. If
the attribute is not defined, the hypervisor default will be used.
<span class="since">Since 3.10.0</span> (QEMU/KVM only).
<p>The optional <code>maxpagesize</code> subelement can be used to
limit the usable page size for HPT guests. Common values are 64 KiB,
16 MiB and 16 GiB; when not specified, the hypervisor default will
be used. <span class="since">Since 4.5.0</span> (QEMU/KVM only).</p>
</dd>
<dt>
<code>vmcoreinfo</code>
</dt>
<dd>Enable QEMU vmcoreinfo device to let the guest kernel save debug
details. <span class="since">Since 4.4.0</span> (QEMU only)
</dd>
<dt>
<code>htm</code>
</dt>
<dd>Configure HTM (Hardware Transational Memory) availability for
pSeries guests. Possible values for the <code>state</code> attribute
are <code>on</code> and <code>off</code>. If the attribute is not
defined, the hypervisor default will be used.
<span class="since">Since 4.6.0</span> (QEMU/KVM only)
</dd>
<dt>
<code>nested-hv</code>
</dt>
<dd>Configure nested HV availability for pSeries guests. This needs to
be enabled from the host (L0) in order to be effective; having HV
support in the (L1) guest is very desiderable if it's planned to
run nested (L2) guests inside it, because it will result in those
nested guests having much better performance than they would when
using KVM PR or TCG.
Possible values for the <code>state</code> attribute are
<code>on</code> and <code>off</code>. If the attribute is not
defined, the hypervisor default will be used.
<span class="since">Since 4.10.0</span> (QEMU/KVM only)
</dd>
</dl>
<h3>
<a id="elementsTime">Time keeping</a>
<a class="headerlink" href="#elementsTime" title="Permalink to this headline">¶</a>
</h3>
<p>
The guest clock is typically initialized from the host clock.
Most operating systems expect the hardware clock to be kept
in UTC, and this is the default. Windows, however, expects
it to be in so called 'localtime'.
</p>
<pre>
...
<clock offset='localtime'>
<timer name='rtc' tickpolicy='catchup' track='guest'>
<catchup threshold='123' slew='120' limit='10000'/>
</timer>
<timer name='pit' tickpolicy='delay'/>
</clock>
...</pre>
<dl>
<dt>
<code>clock</code>
</dt>
<dd>
<p>The <code>offset</code> attribute takes four possible
values, allowing fine grained control over how the guest
clock is synchronized to the host. NB, not all hypervisors
support all modes.</p>
<dl>
<dt>
<code>utc</code>
</dt>
<dd>
The guest clock will always be synchronized to UTC when
booted.
<span class="since">Since 0.9.11</span> 'utc' mode can be converted
to 'variable' mode, which can be controlled by using the
<code>adjustment</code> attribute. If the value is 'reset', the
conversion is never done (not all hypervisors can
synchronize to UTC on each boot; use of 'reset' will cause
an error on those hypervisors). A numeric value
forces the conversion to 'variable' mode using the value as the
initial adjustment. The default <code>adjustment</code> is
hypervisor specific.
</dd>
<dt>
<code>localtime</code>
</dt>
<dd>
The guest clock will be synchronized to the host's configured
timezone when booted, if any.
<span class="since">Since 0.9.11,</span> the <code>adjustment</code>
attribute behaves the same as in 'utc' mode.
</dd>
<dt>
<code>timezone</code>
</dt>
<dd>
The guest clock will be synchronized to the requested timezone
using the <code>timezone</code> attribute.
<span class="since">Since 0.7.7</span>
</dd>
<dt>
<code>variable</code>
</dt>
<dd>
The guest clock will have an arbitrary offset applied
relative to UTC or localtime, depending on the <code>basis</code>
attribute. The delta relative to UTC (or localtime) is specified
in seconds, using the <code>adjustment</code> attribute.
The guest is free to adjust the RTC over time and expect
that it will be honored at next reboot. This is in
contrast to 'utc' and 'localtime' mode (with the optional
attribute adjustment='reset'), where the RTC adjustments are
lost at each reboot. <span class="since">Since 0.7.7</span>
<span class="since">Since 0.9.11</span> the <code>basis</code>
attribute can be either 'utc' (default) or 'localtime'.
</dd>
</dl>
<p>
A <code>clock</code> may have zero or more
<code>timer</code> sub-elements. <span class="since">Since
0.8.0</span>
</p>
</dd>
<dt>
<code>timer</code>
</dt>
<dd>
<p>
Each timer element requires a <code>name</code> attribute,
and has other optional attributes that depend on
the <code>name</code> specified. Various hypervisors
support different combinations of attributes.
</p>
<dl>
<dt>
<code>name</code>
</dt>
<dd>
The <code>name</code> attribute selects which timer is
being modified, and can be one of
"platform" (currently unsupported),
"hpet" (libxl, xen, qemu), "kvmclock" (qemu),
"pit" (qemu), "rtc" (qemu), "tsc" (libxl) or "hypervclock"
(qemu - <span class="since">since 1.2.2</span>).
The <code>hypervclock</code> timer adds support for the
reference time counter and the reference page for iTSC
feature for guests running the Microsoft Windows
operating system.
</dd>
<dt>
<code>track</code>
</dt>
<dd>
The <code>track</code> attribute specifies what the timer
tracks, and can be "boot", "guest", or "wall".
Only valid for <code>name="rtc"</code>
or <code>name="platform"</code>.
</dd>
<dt>
<code>tickpolicy</code>
</dt>
<dd>
<p>
The <code>tickpolicy</code> attribute determines what
happens when QEMU misses a deadline for injecting a
tick to the guest:
</p>
<dl>
<dt>
<code>delay</code>
</dt>
<dd>Continue to deliver ticks at the normal rate.
The guest time will be delayed due to the late
tick</dd>
<dt>
<code>catchup</code>
</dt>
<dd>Deliver ticks at a higher rate to catch up
with the missed tick. The guest time should
not be delayed once catchup is complete.</dd>
<dt>
<code>merge</code>
</dt>
<dd>Merge the missed tick(s) into one tick and
inject. The guest time may be delayed, depending
on how the OS reacts to the merging of ticks</dd>
<dt>
<code>discard</code>
</dt>
<dd>Throw away the missed tick(s) and continue
with future injection normally. The guest time
may be delayed, unless the OS has explicit
handling of lost ticks</dd>
</dl>
<p>If the policy is "catchup", there can be further details in
the <code>catchup</code> sub-element.</p>
<dl>
<dt>
<code>catchup</code>
</dt>
<dd>
The <code>catchup</code> element has three optional
attributes, each a positive integer. The attributes
are <code>threshold</code>, <code>slew</code>,
and <code>limit</code>.
</dd>
</dl>
<p>
Note that hypervisors are not required to support all policies across all time sources
</p>
</dd>
<dt>
<code>frequency</code>
</dt>
<dd>
The <code>frequency</code> attribute is an unsigned
integer specifying the frequency at
which <code>name="tsc"</code> runs.
</dd>
<dt>
<code>mode</code>
</dt>
<dd>
The <code>mode</code> attribute controls how
the <code>name="tsc"</code> timer is managed, and can be
"auto", "native", "emulate", "paravirt", or "smpsafe".
Other timers are always emulated.
</dd>
<dt>
<code>present</code>
</dt>
<dd>
The <code>present</code> attribute can be "yes" or "no" to
specify whether a particular timer is available to the guest.
</dd>
</dl>
</dd>
</dl>
<h3>
<a id="elementsPerf">Performance monitoring events</a>
<a class="headerlink" href="#elementsPerf" title="Permalink to this headline">¶</a>
</h3>
<p>
Some platforms allow monitoring of performance of the virtual machine and
the code executed inside. To enable the performance monitoring events
you can either specify them in the <code>perf</code> element or enable
them via <code>virDomainSetPerfEvents</code> API. The performance values
are then retrieved using the virConnectGetAllDomainStats API.
<span class="since">Since 2.0.0</span>
</p>
<pre>
...
<perf>
<event name='cmt' enabled='yes'/>
<event name='mbmt' enabled='no'/>
<event name='mbml' enabled='yes'/>
<event name='cpu_cycles' enabled='no'/>
<event name='instructions' enabled='yes'/>
<event name='cache_references' enabled='no'/>
<event name='cache_misses' enabled='no'/>
<event name='branch_instructions' enabled='no'/>
<event name='branch_misses' enabled='no'/>
<event name='bus_cycles' enabled='no'/>
<event name='stalled_cycles_frontend' enabled='no'/>
<event name='stalled_cycles_backend' enabled='no'/>
<event name='ref_cpu_cycles' enabled='no'/>
<event name='cpu_clock' enabled='no'/>
<event name='task_clock' enabled='no'/>
<event name='page_faults' enabled='no'/>
<event name='context_switches' enabled='no'/>
<event name='cpu_migrations' enabled='no'/>
<event name='page_faults_min' enabled='no'/>
<event name='page_faults_maj' enabled='no'/>
<event name='alignment_faults' enabled='no'/>
<event name='emulation_faults' enabled='no'/>
</perf>
...
</pre>
<table class="top_table">
<tr>
<th>event name</th>
<th>Description</th>
<th>stats parameter name</th>
</tr>
<tr>
<td>
<code>cmt</code>
</td>
<td>usage of l3 cache in bytes by applications running on the platform</td>
<td>
<code>perf.cmt</code>
</td>
</tr>
<tr>
<td>
<code>mbmt</code>
</td>
<td>total system bandwidth from one level of cache</td>
<td>
<code>perf.mbmt</code>
</td>
</tr>
<tr>
<td>
<code>mbml</code>
</td>
<td>bandwidth of memory traffic for a memory controller</td>
<td>
<code>perf.mbml</code>
</td>
</tr>
<tr>
<td>
<code>cpu_cycles</code>
</td>
<td>the count of CPU cycles (total/elapsed)</td>
<td>
<code>perf.cpu_cycles</code>
</td>
</tr>
<tr>
<td>
<code>instructions</code>
</td>
<td>the count of instructions by applications running on the platform</td>
<td>
<code>perf.instructions</code>
</td>
</tr>
<tr>
<td>
<code>cache_references</code>
</td>
<td>the count of cache hits by applications running on the platform</td>
<td>
<code>perf.cache_references</code>
</td>
</tr>
<tr>
<td>
<code>cache_misses</code>
</td>
<td>the count of cache misses by applications running on the platform</td>
<td>
<code>perf.cache_misses</code>
</td>
</tr>
<tr>
<td>
<code>branch_instructions</code>
</td>
<td>the count of branch instructions by applications running on the platform</td>
<td>
<code>perf.branch_instructions</code>
</td>
</tr>
<tr>
<td>
<code>branch_misses</code>
</td>
<td>the count of branch misses by applications running on the platform</td>
<td>
<code>perf.branch_misses</code>
</td>
</tr>
<tr>
<td>
<code>bus_cycles</code>
</td>
<td>the count of bus cycles by applications running on the platform</td>
<td>
<code>perf.bus_cycles</code>
</td>
</tr>
<tr>
<td>
<code>stalled_cycles_frontend</code>
</td>
<td>the count of stalled CPU cycles in the frontend of the instruction
processor pipeline by applications running on the platform</td>
<td>
<code>perf.stalled_cycles_frontend</code>
</td>
</tr>
<tr>
<td>
<code>stalled_cycles_backend</code>
</td>
<td>the count of stalled CPU cycles in the backend of the instruction
processor pipeline by applications running on the platform</td>
<td>
<code>perf.stalled_cycles_backend</code>
</td>
</tr>
<tr>
<td>
<code>ref_cpu_cycles</code>
</td>
<td>the count of total CPU cycles not affected by CPU frequency scaling
by applications running on the platform</td>
<td>
<code>perf.ref_cpu_cycles</code>
</td>
</tr>
<tr>
<td>
<code>cpu_clock</code>
</td>
<td>the count of CPU clock time, as measured by a monotonic
high-resolution per-CPU timer, by applications running on
the platform</td>
<td>
<code>perf.cpu_clock</code>
</td>
</tr>
<tr>
<td>
<code>task_clock</code>
</td>
<td>the count of task clock time, as measured by a monotonic
high-resolution CPU timer, specific to the task that
is run by applications running on the platform</td>
<td>
<code>perf.task_clock</code>
</td>
</tr>
<tr>
<td>
<code>page_faults</code>
</td>
<td>the count of page faults by applications running on the
platform. This includes minor, major, invalid and other
types of page faults</td>
<td>
<code>perf.page_faults</code>
</td>
</tr>
<tr>
<td>
<code>context_switches</code>
</td>
<td>the count of context switches by applications running on
the platform</td>
<td>
<code>perf.context_switches</code>
</td>
</tr>
<tr>
<td>
<code>cpu_migrations</code>
</td>
<td>the count of CPU migrations, that is, where the process
moved from one logical processor to another, by
applications running on the platform</td>
<td>
<code>perf.cpu_migrations</code>
</td>
</tr>
<tr>
<td>
<code>page_faults_min</code>
</td>
<td>the count of minor page faults, that is, where the
page was present in the page cache, and therefore
the fault avoided loading it from storage, by
applications running on the platform</td>
<td>
<code>perf.page_faults_min</code>
</td>
</tr>
<tr>
<td>
<code>page_faults_maj</code>
</td>
<td>the count of major page faults, that is, where the
page was not present in the page cache, and
therefore had to be fetched from storage, by
applications running on the platform</td>
<td>
<code>perf.page_faults_maj</code>
</td>
</tr>
<tr>
<td>
<code>alignment_faults</code>
</td>
<td>the count of alignment faults, that is when
the load or store is not aligned properly, by
applications running on the platform</td>
<td>
<code>perf.alignment_faults</code>
</td>
</tr>
<tr>
<td>
<code>emulation_faults</code>
</td>
<td>the count of emulation faults, that is when
the kernel traps on unimplemented instrucions
and emulates them for user space, by
applications running on the platform</td>
<td>
<code>perf.emulation_faults</code>
</td>
</tr>
</table>
<h3>
<a id="elementsDevices">Devices</a>
<a class="headerlink" href="#elementsDevices" title="Permalink to this headline">¶</a>
</h3>
<p>
The final set of XML elements are all used to describe devices
provided to the guest domain. All devices occur as children
of the main <code>devices</code> element.
<span class="since">Since 0.1.3</span>
</p>
<pre>
...
<devices>
<emulator>/usr/lib/xen/bin/qemu-dm</emulator>
</devices>
...</pre>
<dl>
<dt>
<a id="elementEmulator">
<code>emulator</code>
</a>
</dt>
<dd>
The contents of the <code>emulator</code> element specify
the fully qualified path to the device model emulator binary.
The <a href="formatcaps.html">capabilities XML</a> specifies
the recommended default emulator to use for each particular
domain type / architecture combination.
</dd>
</dl>
<p>
To help users identifying devices they care about, every
device can have direct child <code>alias</code> element
which then has <code>name</code> attribute where users can
store identifier for the device. The identifier has to have
"ua-" prefix and must be unique within the domain. Additionally, the
identifier must consist only of the following characters:
<code>[a-zA-Z0-9_-]</code>.
<span class="since">Since 3.9.0</span>
</p>
<pre>
<devices>
<disk type='file'>
<alias name='ua-myDisk'/>
</disk>
<interface type='network' trustGuestRxFilters='yes'>
<alias name='ua-myNIC'/>
</interface>
...
</devices>
</pre>
<h4>
<a id="elementsDisks">Hard drives, floppy disks, CDROMs</a>
<a class="headerlink" href="#elementsDisks" title="Permalink to this headline">¶</a>
</h4>
<p>
Any device that looks like a disk, be it a floppy, harddisk,
cdrom, or paravirtualized driver is specified via the <code>disk</code>
element.
</p>
<pre>
...
<devices>
<disk type='file' snapshot='external'>
<driver name="tap" type="aio" cache="default"/>
<source file='/var/lib/xen/images/fv0' startupPolicy='optional'>
<seclabel relabel='no'/>
</source>
<target dev='hda' bus='ide'/>
<iotune>
<total_bytes_sec>10000000</total_bytes_sec>
<read_iops_sec>400000</read_iops_sec>
<write_iops_sec>100000</write_iops_sec>
</iotune>
<boot order='2'/>
<encryption type='...'>
...
</encryption>
<shareable/>
<serial>
...
</serial>
</disk>
...
<disk type='network'>
<driver name="qemu" type="raw" io="threads" ioeventfd="on" event_idx="off"/>
<source protocol="sheepdog" name="image_name">
<host name="hostname" port="7000"/>
</source>
<target dev="hdb" bus="ide"/>
<boot order='1'/>
<transient/>
<address type='drive' controller='0' bus='1' unit='0'/>
</disk>
<disk type='network'>
<driver name="qemu" type="raw"/>
<source protocol="rbd" name="image_name2">
<host name="hostname" port="7000"/>
<snapshot name="snapname"/>
<config file="/path/to/file"/>
<auth username='myuser'>
<secret type='ceph' usage='mypassid'/>
</auth>
</source>
<target dev="hdc" bus="ide"/>
</disk>
<disk type='block' device='cdrom'>
<driver name='qemu' type='raw'/>
<target dev='hdd' bus='ide' tray='open'/>
<readonly/>
</disk>
<disk type='network' device='cdrom'>
<driver name='qemu' type='raw'/>
<source protocol="http" name="url_path">
<host name="hostname" port="80"/>
</source>
<target dev='hde' bus='ide' tray='open'/>
<readonly/>
</disk>
<disk type='network' device='cdrom'>
<driver name='qemu' type='raw'/>
<source protocol="https" name="url_path">
<host name="hostname" port="443"/>
</source>
<target dev='hdf' bus='ide' tray='open'/>
<readonly/>
</disk>
<disk type='network' device='cdrom'>
<driver name='qemu' type='raw'/>
<source protocol="ftp" name="url_path">
<host name="hostname" port="21"/>
</source>
<target dev='hdg' bus='ide' tray='open'/>
<readonly/>
</disk>
<disk type='network' device='cdrom'>
<driver name='qemu' type='raw'/>
<source protocol="ftps" name="url_path">
<host name="hostname" port="990"/>
</source>
<target dev='hdh' bus='ide' tray='open'/>
<readonly/>
</disk>
<disk type='network' device='cdrom'>
<driver name='qemu' type='raw'/>
<source protocol="tftp" name="url_path">
<host name="hostname" port="69"/>
</source>
<target dev='hdi' bus='ide' tray='open'/>
<readonly/>
</disk>
<disk type='block' device='lun'>
<driver name='qemu' type='raw'/>
<source dev='/dev/sda'>
<reservations managed='no'>
<source type='unix' path='/path/to/qemu-pr-helper' mode='client'/>
</reservations>
<target dev='sda' bus='scsi'/>
<address type='drive' controller='0' bus='0' target='3' unit='0'/>
</disk>
<disk type='block' device='disk'>
<driver name='qemu' type='raw'/>
<source dev='/dev/sda'/>
<geometry cyls='16383' heads='16' secs='63' trans='lba'/>
<blockio logical_block_size='512' physical_block_size='4096'/>
<target dev='hdj' bus='ide'/>
</disk>
<disk type='volume' device='disk'>
<driver name='qemu' type='raw'/>
<source pool='blk-pool0' volume='blk-pool0-vol0'/>
<target dev='hdk' bus='ide'/>
</disk>
<disk type='network' device='disk'>
<driver name='qemu' type='raw'/>
<source protocol='iscsi' name='iqn.2013-07.com.example:iscsi-nopool/2'>
<host name='example.com' port='3260'/>
<auth username='myuser'>
<secret type='iscsi' usage='libvirtiscsi'/>
</auth>
</source>
<target dev='vda' bus='virtio'/>
</disk>
<disk type='network' device='lun'>
<driver name='qemu' type='raw'/>
<source protocol='iscsi' name='iqn.2013-07.com.example:iscsi-nopool/1'>
<host name='example.com' port='3260'/>
<auth username='myuser'>
<secret type='iscsi' usage='libvirtiscsi'/>
</auth>
</source>
<target dev='sdb' bus='scsi'/>
</disk>
<disk type='network' device='lun'>
<driver name='qemu' type='raw'/>
<source protocol='iscsi' name='iqn.2013-07.com.example:iscsi-nopool/0'>
<host name='example.com' port='3260'/>
<initiator>
<iqn name='iqn.2013-07.com.example:client'/>
</initiator>
</source>
<target dev='sdb' bus='scsi'/>
</disk>
<disk type='volume' device='disk'>
<driver name='qemu' type='raw'/>
<source pool='iscsi-pool' volume='unit:0:0:1' mode='host'/>
<target dev='vdb' bus='virtio'/>
</disk>
<disk type='volume' device='disk'>
<driver name='qemu' type='raw'/>
<source pool='iscsi-pool' volume='unit:0:0:2' mode='direct'/>
<target dev='vdc' bus='virtio'/>
</disk>
<disk type='file' device='disk'>
<driver name='qemu' type='qcow2' queues='4'/>
<source file='/var/lib/libvirt/images/domain.qcow'/>
<backingStore type='file'>
<format type='qcow2'/>
<source file='/var/lib/libvirt/images/snapshot.qcow'/>
<backingStore type='block'>
<format type='raw'/>
<source dev='/dev/mapper/base'/>
<backingStore/>
</backingStore>
</backingStore>
<target dev='vdd' bus='virtio'/>
</disk>
</devices>
...</pre>
<dl>
<dt>
<code>disk</code>
</dt>
<dd>The <code>disk</code> element is the main container for
describing disks and supports the following attributes:
<dl><dt><code>type</code></dt><dd>
Valid values are "file", "block",
"dir" (<span class="since">since 0.7.5</span>),
"network" (<span class="since">since 0.8.7</span>), or
"volume" (<span class="since">since 1.0.5</span>)
and refer to the underlying source for the disk.
<span class="since">Since 0.0.3</span>
</dd><dt><code>device</code></dt><dd>
Indicates how the disk is to be exposed to the guest OS. Possible
values for this attribute are "floppy", "disk", "cdrom", and "lun",
defaulting to "disk".
<p>
Using "lun" (<span class="since">since 0.9.10</span>) is only
valid when the <code>type</code> is "block" or "network" for
<code>protocol='iscsi'</code> or when the <code>type</code>
is "volume" when using an iSCSI source <code>pool</code>
for <code>mode</code> "host" or as an
<a href="http://wiki.libvirt.org/page/NPIV_in_libvirt">NPIV</a>
virtual Host Bus Adapter (vHBA) using a Fibre Channel storage pool.
Configured in this manner, the LUN behaves identically to "disk",
except that generic SCSI commands from the guest are accepted
and passed through to the physical device. Also note that
device='lun' will only be recognized for actual raw devices,
but never for individual partitions or LVM partitions (in those
cases, the kernel will reject the generic SCSI commands, making
it identical to device='disk').
<span class="since">Since 0.1.4</span>
</p>
</dd><dt><code>rawio</code></dt><dd>
Indicates whether the disk needs rawio capability. Valid
settings are "yes" or "no" (default is "no"). If any one disk
in a domain has rawio='yes', rawio capability will be enabled
for all disks in the domain (because, in the case of QEMU, this
capability can only be set on a per-process basis). This attribute
is only valid when device is "lun". NB, <code>rawio</code> intends
to confine the capability per-device, however, current QEMU
implementation gives the domain process broader capability
than that (per-process basis, affects all the domain disks).
To confine the capability as much as possible for QEMU driver
as this stage, <code>sgio</code> is recommended, it's more
secure than <code>rawio</code>.
<span class="since">Since 0.9.10</span>
</dd><dt><code>sgio</code></dt><dd>
If supported by the hypervisor and OS, indicates whether
unprivileged SG_IO commands are filtered for the disk. Valid
settings are "filtered" or "unfiltered" where the default is
"filtered". Only available when the <code>device</code> is 'lun'.
<span class="since">Since 1.0.2</span>
</dd><dt><code>snapshot</code></dt><dd>
Indicates the default behavior of the disk during disk snapshots:
"<code>internal</code>" requires a file format such as qcow2 that
can store both the snapshot and the data changes since the snapshot;
"<code>external</code>" will separate the snapshot from the live
data; and "<code>no</code>" means the disk will not participate in
snapshots. Read-only disks default to "<code>no</code>", while the
default for other disks depends on the hypervisor's capabilities.
Some hypervisors allow a per-snapshot choice as well, during
<a href="formatsnapshot.html">domain snapshot creation</a>.
Not all snapshot modes are supported; for example, enabling
snapshots with a transient disk generally does not make sense.
<span class="since">Since 0.9.5</span>
</dd></dl>
</dd>
<dt>
<code>source</code>
</dt>
<dd>Representation of the disk <code>source</code> depends on the
disk <code>type</code> attribute value as follows:
<dl><dt><code>file</code></dt><dd>
The <code>file</code> attribute specifies the fully-qualified
path to the file holding the disk.
<span class="since">Since 0.0.3</span>
</dd><dt><code>block</code></dt><dd>
The <code>dev</code> attribute specifies the fully-qualified path
to the host device to serve as the disk.
<span class="since">Since 0.0.3</span>
</dd><dt><code>dir</code></dt><dd>
The <code>dir</code> attribute specifies the fully-qualified path
to the directory to use as the disk.
<span class="since">Since 0.7.5</span>
</dd><dt><code>network</code></dt><dd>
The <code>protocol</code> attribute specifies the protocol to
access to the requested image. Possible values are "nbd",
"iscsi", "rbd", "sheepdog", "gluster" or "vxhs".
<p>If the <code>protocol</code> attribute is "rbd", "sheepdog",
"gluster", or "vxhs", an additional attribute <code>name</code>
is mandatory to specify which volume/image will be used.
</p>
<p>For "nbd", the <code>name</code> attribute is optional. TLS
transport for NBD can be enabled by setting the <code>tls</code>
attribute to <code>yes</code>. For the QEMU hypervisor, usage of
a TLS environment can also be globally controlled on the host by
the <code>nbd_tls</code> and <code>nbd_tls_x509_cert_dir</code> in
/etc/libvirt/qemu.conf.
('tls' <span class="since">Since 4.5.0</span>)
</p>
<p>For "iscsi" (<span class="since">since 1.0.4</span>), the
<code>name</code> attribute may include a logical unit number,
separated from the target's name by a slash (e.g.,
<code>iqn.2013-07.com.example:iscsi-pool/1</code>). If not
specified, the default LUN is zero.
</p>
<p>For "vxhs" (<span class="since">since 3.8.0</span>), the
<code>name</code> is the UUID of the volume, assigned by the
HyperScale server. Additionally, an optional attribute
<code>tls</code> (QEMU only) can be used to control whether a
VxHS block device would utilize a hypervisor configured TLS
X.509 certificate environment in order to encrypt the data
channel. For the QEMU hypervisor, usage of a TLS environment can
also be globally controlled on the host by the
<code>vxhs_tls</code> and <code>vxhs_tls_x509_cert_dir</code> or
<code>default_tls_x509_cert_dir</code> settings in the file
/etc/libvirt/qemu.conf. If <code>vxhs_tls</code> is enabled,
then unless the domain <code>tls</code> attribute is set to "no",
libvirt will use the host configured TLS environment. If the
<code>tls</code> attribute is set to "yes", then regardless of
the qemu.conf setting, TLS authentication will be attempted.
</p>
<span class="since">Since 0.8.7</span>
</dd><dt><code>volume</code></dt><dd>
The underlying disk source is represented by attributes
<code>pool</code> and <code>volume</code>. Attribute
<code>pool</code> specifies the name of the
<a href="formatstorage.html">storage pool</a> (managed
by libvirt) where the disk source resides. Attribute
<code>volume</code> specifies the name of storage volume (managed
by libvirt) used as the disk source. The value for the
<code>volume</code> attribute will be the output from the "Name"
column of a <code>virsh vol-list [pool-name]</code> command.
<p>
Use the attribute <code>mode</code>
(<span class="since">since 1.1.1</span>) to indicate how to
represent the LUN as the disk source. Valid values are
"direct" and "host". If <code>mode</code> is not specified,
the default is to use "host".
Using "direct" as the <code>mode</code> value indicates to use
the <a href="formatstorage.html">storage pool's</a>
<code>source</code> element <code>host</code> attribute as
the disk source to generate the libiscsi URI (e.g.
'file=iscsi://example.com:3260/iqn.2013-07.com.example:iscsi-pool/1').
Using "host" as the <code>mode</code> value indicates to use the
LUN's path as it shows up on host (e.g.
'file=/dev/disk/by-path/ip-example.com:3260-iscsi-iqn.2013-07.com.example:iscsi-pool-lun-1').
Using a LUN from an iSCSI source pool provides the same
features as a <code>disk</code> configured using
<code>type</code> 'block' or 'network' and <code>device</code>
of 'lun' with respect to how the LUN is presented to and
may be used by the guest.
<span class="since">Since 1.0.5</span>
</p>
</dd></dl>
With "file", "block", and "volume", one or more optional
sub-elements <code>seclabel</code>, <a href="#seclabel">described
below</a> (and <span class="since">since 0.9.9</span>), can be
used to override the domain security labeling policy for just
that source file. (NB, for "volume" type disk, <code>seclabel</code>
is only valid when the specified storage volume is of 'file' or
'block' type).
<p>
The <code>source</code> element may also have the <code>index</code>
attribute with same semantics the <a href="#elementsDiskBackingStoreIndex"><code>index</code></a> attribute of <code>backingStore</code>
</p>
<p>
The <code>source</code> element may contain the following sub elements:
</p>
<dl><dt><code>host</code></dt><dd><p>
When the disk <code>type</code> is "network", the <code>source</code>
may have zero or more <code>host</code> sub-elements used to
specify the hosts to connect.
The <code>host</code> element supports 4 attributes, viz. "name",
"port", "transport" and "socket", which specify the hostname,
the port number, transport type and path to socket, respectively.
The meaning of this element and the number of the elements depend
on the protocol attribute.
</p><table class="top_table"><tr><th> Protocol </th><th> Meaning </th><th> Number of hosts </th><th> Default port </th></tr><tr><td> nbd </td><td> a server running nbd-server </td><td> only one </td><td> 10809 </td></tr><tr><td> iscsi </td><td> an iSCSI server </td><td> only one </td><td> 3260 </td></tr><tr><td> rbd </td><td> monitor servers of RBD </td><td> one or more </td><td> librados default </td></tr><tr><td> sheepdog </td><td> one of the sheepdog servers (default is localhost:7000) </td><td> zero or one </td><td> 7000 </td></tr><tr><td> gluster </td><td> a server running glusterd daemon </td><td> one or more (<span class="since">Since 2.1.0</span>), just one prior to that </td><td> 24007 </td></tr><tr><td> vxhs </td><td> a server running Veritas HyperScale daemon </td><td> only one </td><td> 9999 </td></tr></table><p>
gluster supports "tcp", "rdma", "unix" as valid values for the
transport attribute. nbd supports "tcp" and "unix". Others only
support "tcp". If nothing is specified, "tcp" is assumed. If the
transport is "unix", the socket attribute specifies the path to an
AF_UNIX socket.
</p></dd><dt><code>snapshot</code></dt><dd>
The <code>name</code> attribute of <code>snapshot</code> element can
optionally specify an internal snapshot name to be used as the
source for storage protocols.
Supported for 'rbd' <span class="since">since 1.2.11 (QEMU only).</span>
</dd><dt><code>config</code></dt><dd>
The <code>file</code> attribute for the <code>config</code> element
provides a fully qualified path to a configuration file to be
provided as a parameter to the client of a networked storage
protocol. Supported for 'rbd' <span class="since">since 1.2.11
(QEMU only).</span>
</dd><dt><code>auth</code></dt><dd><span class="since">Since libvirt 3.9.0</span>, the
<code>auth</code> element is supported for a disk
<code>type</code> "network" that is using a <code>source</code>
element with the <code>protocol</code> attributes "rbd" or "iscsi".
If present, the <code>auth</code> element provides the
authentication credentials needed to access the source. It
includes a mandatory attribute <code>username</code>, which
identifies the username to use during authentication, as well
as a sub-element <code>secret</code> with mandatory
attribute <code>type</code>, to tie back to
a <a href="formatsecret.html">libvirt secret object</a> that
holds the actual password or other credentials (the domain XML
intentionally does not expose the password, only the reference
to the object that does manage the password).
Known secret types are "ceph" for Ceph RBD network sources and
"iscsi" for CHAP authentication of iSCSI targets.
Both will require either a <code>uuid</code> attribute
with the UUID of the secret object or a <code>usage</code>
attribute matching the key that was specified in the
secret object.
</dd><dt><code>encryption</code></dt><dd><span class="since">Since libvirt 3.9.0</span>, the
<code>encryption</code> can be a sub-element of the
<code>source</code> element for encrypted storage sources.
If present, specifies how the storage source is encrypted
See the
<a href="formatstorageencryption.html">Storage Encryption</a>
page for more information.
<p/>
Note that the 'qcow' format of encryption is broken and thus is no
longer supported for use with disk images.
(<span class="since">Since libvirt 4.5.0</span>)
</dd><dt><code>reservations</code></dt><dd><span class="since">Since libvirt 4.4.0</span>, the
<code>reservations</code> can be a sub-element of the
<code>source</code> element for storage sources (QEMU driver only).
If present it enables persistent reservations for SCSI
based disks. The element has one mandatory attribute
<code>managed</code> with accepted values <code>yes</code> and
<code>no</code>. If <code>managed</code> is enabled libvirt prepares
and manages any resources needed. When the persistent reservations
are unmanaged, then the hypervisor acts as a client and the path to
the server socket must be provided in the child element
<code>source</code>, which currently accepts only the following
attributes:
<code>type</code> with one value <code>unix</code>,
<code>path</code> path to the socket, and
finally <code>mode</code> which accepts one value
<code>client</code> specifying the role of hypervisor.
It's recommended to allow libvirt manage the persistent
reservations.
</dd><dt><code>initiator</code></dt><dd><span class="since">Since libvirt 4.7.0</span>, the
<code>initiator</code> element is supported for a disk
<code>type</code> "network" that is using a <code>source</code>
element with the <code>protocol</code> attribute "iscsi".
If present, the <code>initiator</code> element provides the
initiator IQN needed to access the source via mandatory
attribute <code>name</code>.
</dd></dl>
<p>
For a "file" or "volume" disk type which represents a cdrom or floppy
(the <code>device</code> attribute), it is possible to define
policy what to do with the disk if the source file is not accessible.
(NB, <code>startupPolicy</code> is not valid for "volume" disk unless
the specified storage volume is of "file" type). This is done by the
<code>startupPolicy</code> attribute
(<span class="since">since 0.9.7</span>),
accepting these values:
</p>
<table class="top_table"><tr><td> mandatory </td><td> fail if missing for any reason (the default) </td></tr><tr><td> requisite </td><td> fail if missing on boot up,
drop if missing on migrate/restore/revert </td></tr><tr><td> optional </td><td> drop if missing at any start attempt </td></tr></table>
<p><span class="since">Since 1.1.2</span> the <code>startupPolicy</code>
is extended to support hard disks besides cdrom and floppy. On guest
cold bootup, if a certain disk is not accessible or its disk chain is
broken, with startupPolicy 'optional' the guest will drop this disk.
This feature doesn't support migration currently.
</p>
</dd>
<dt>
<code>backingStore</code>
</dt>
<dd>
This element describes the backing store used by the disk
specified by sibling <code>source</code> element. It is
currently ignored on input and only used for output to
describe the detected backing chains of running
domains <span class="since">since 1.2.4</span> (although a
future version of libvirt may start accepting chains on input,
or output information for offline domains). An
empty <code>backingStore</code> element means the sibling
source is self-contained and is not based on any backing
store. For backing chain information to be accurate, the
backing format must be correctly specified in the metadata of
each file of the chain (files created by libvirt satisfy this
property, but using existing external files for snapshot or
block copy operations requires the end user to pre-create the
file correctly). The following attributes are
supported in <code>backingStore</code>:
<dl><dt><code>type</code></dt><dd>
The <code>type</code> attribute represents the type of disk used
by the backing store, see disk type attribute above for more
details and possible values.
</dd><dt><code><a id="elementsDiskBackingStoreIndex">index</a></code></dt><dd>
This attribute is only valid in output (and ignored on input) and
it can be used to refer to a specific part of the disk chain when
doing block operations (such as via the
<code>virDomainBlockRebase</code> API). For example,
<code>vda[2]</code> refers to the backing store with
<code>index='2'</code> of the disk with <code>vda</code> target.
</dd></dl>
Moreover, <code>backingStore</code> supports the following sub-elements:
<dl><dt><code>format</code></dt><dd>
The <code>format</code> element contains <code>type</code>
attribute which specifies the internal format of the backing
store, such as <code>raw</code> or <code>qcow2</code>.
</dd><dt><code>source</code></dt><dd>
This element has the same structure as the <code>source</code>
element in <code>disk</code>. It specifies which file, device,
or network location contains the data of the described backing
store.
</dd><dt><code>backingStore</code></dt><dd>
If the backing store is not self-contained, the next element
in the chain is described by nested <code>backingStore</code>
element.
</dd></dl>
</dd>
<dt>
<code>mirror</code>
</dt>
<dd>
This element is present if the hypervisor has started a
long-running block job operation, where the mirror location in
the <code>source</code> sub-element will eventually have the
same contents as the source, and with the file format in the
sub-element <code>format</code> (which might differ from the
format of the source). The details of the <code>source</code>
sub-element are determined by the <code>type</code> attribute
of the mirror, similar to what is done for the
overall <code>disk</code> device element. The <code>job</code>
attribute mentions which API started the operation ("copy" for
the <code>virDomainBlockRebase</code> API, or "active-commit"
for the <code>virDomainBlockCommit</code>
API), <span class="since">since 1.2.7</span>. The
attribute <code>ready</code>, if present, tracks progress of
the job: <code>yes</code> if the disk is known to be ready to
pivot, or, <span class="since">since
1.2.7</span>, <code>abort</code> or <code>pivot</code> if the
job is in the process of completing. If <code>ready</code> is
not present, the disk is probably still
copying. For now, this element only valid in output; it is
ignored on input. The <code>source</code> sub-element exists
for all two-phase jobs <span class="since">since 1.2.6</span>.
Older libvirt supported only block copy to a
file, <span class="since">since 0.9.12</span>; for
compatibility with older clients, such jobs include redundant
information in the attributes <code>file</code>
and <code>format</code> in the <code>mirror</code> element.
</dd>
<dt>
<code>target</code>
</dt>
<dd>The <code>target</code> element controls the bus / device
under which the disk is exposed to the guest
OS. The <code>dev</code> attribute indicates the "logical"
device name. The actual device name specified is not
guaranteed to map to the device name in the guest OS. Treat it
as a device ordering hint. The optional <code>bus</code>
attribute specifies the type of disk device to emulate;
possible values are driver specific, with typical values being
"ide", "scsi", "virtio", "xen", "usb", "sata", or
"sd" <span class="since">"sd" since 1.1.2</span>. If omitted, the bus
type is inferred from the style of the device name (e.g. a device named
'sda' will typically be exported using a SCSI bus). The optional
attribute <code>tray</code> indicates the tray status of the
removable disks (i.e. CDROM or Floppy disk), the value can be either
"open" or "closed", defaults to "closed". NB, the value of
<code>tray</code> could be updated while the domain is running.
The optional attribute <code>removable</code> sets the
removable flag for USB disks, and its value can be either "on"
or "off", defaulting to "off". <span class="since">Since
0.0.3; <code>bus</code> attribute since 0.4.3;
<code>tray</code> attribute since 0.9.11; "usb" attribute value since
after 0.4.4; "sata" attribute value since 0.9.7; "removable" attribute
value since 1.1.3</span>
</dd>
<dt>
<code>iotune</code>
</dt>
<dd>The optional <code>iotune</code> element provides the
ability to provide additional per-device I/O tuning, with
values that can vary for each device (contrast this to
the <a href="#elementsBlockTuning"><code><blkiotune></code></a>
element, which applies globally to the domain). Currently,
the only tuning available is Block I/O throttling for qemu.
This element has optional sub-elements; any sub-element not
specified or given with a value of 0 implies no
limit. <span class="since">Since 0.9.8</span>
<dl><dt><code>total_bytes_sec</code></dt><dd>The optional <code>total_bytes_sec</code> element is the
total throughput limit in bytes per second. This cannot
appear with <code>read_bytes_sec</code>
or <code>write_bytes_sec</code>.</dd><dt><code>read_bytes_sec</code></dt><dd>The optional <code>read_bytes_sec</code> element is the
read throughput limit in bytes per second.</dd><dt><code>write_bytes_sec</code></dt><dd>The optional <code>write_bytes_sec</code> element is the
write throughput limit in bytes per second.</dd><dt><code>total_iops_sec</code></dt><dd>The optional <code>total_iops_sec</code> element is the
total I/O operations per second. This cannot
appear with <code>read_iops_sec</code>
or <code>write_iops_sec</code>.</dd><dt><code>read_iops_sec</code></dt><dd>The optional <code>read_iops_sec</code> element is the
read I/O operations per second.</dd><dt><code>write_iops_sec</code></dt><dd>The optional <code>write_iops_sec</code> element is the
write I/O operations per second.</dd><dt><code>total_bytes_sec_max</code></dt><dd>The optional <code>total_bytes_sec_max</code> element is the
maximum total throughput limit in bytes per second. This cannot
appear with <code>read_bytes_sec_max</code>
or <code>write_bytes_sec_max</code>.</dd><dt><code>read_bytes_sec_max</code></dt><dd>The optional <code>read_bytes_sec_max</code> element is the
maximum read throughput limit in bytes per second.</dd><dt><code>write_bytes_sec_max</code></dt><dd>The optional <code>write_bytes_sec_max</code> element is the
maximum write throughput limit in bytes per second.</dd><dt><code>total_iops_sec_max</code></dt><dd>The optional <code>total_iops_sec_max</code> element is the
maximum total I/O operations per second. This cannot
appear with <code>read_iops_sec_max</code>
or <code>write_iops_sec_max</code>.</dd><dt><code>read_iops_sec_max</code></dt><dd>The optional <code>read_iops_sec_max</code> element is the
maximum read I/O operations per second.</dd><dt><code>write_iops_sec_max</code></dt><dd>The optional <code>write_iops_sec_max</code> element is the
maximum write I/O operations per second.</dd><dt><code>size_iops_sec</code></dt><dd>The optional <code>size_iops_sec</code> element is the
size of I/O operations per second.
<p><span class="since">Throughput limits since 1.2.11 and QEMU 1.7</span></p>
</dd><dt><code>group_name</code></dt><dd>The optional <code>group_name</code> provides the cability
to share I/O throttling quota between multiple drives. This
prevents end-users from circumventing a hosting provider's
throttling policy by splitting 1 large drive in N small drives
and getting N times the normal throttling quota. Any name may
be used.
<p><span class="since">group_name since 3.0.0 and QEMU 2.4</span></p>
</dd><dt><code>total_bytes_sec_max_length</code></dt><dd>The optional <code>total_bytes_sec_max_length</code>
element is the maximum duration in seconds for the
<code>total_bytes_sec_max</code> burst period. Only valid
when the <code>total_bytes_sec_max</code> is set.</dd><dt><code>read_bytes_sec_max_length</code></dt><dd>The optional <code>read_bytes_sec_max_length</code>
element is the maximum duration in seconds for the
<code>read_bytes_sec_max</code> burst period. Only valid
when the <code>read_bytes_sec_max</code> is set.</dd><dt><code>write_bytes_sec_max</code></dt><dd>The optional <code>write_bytes_sec_max_length</code>
element is the maximum duration in seconds for the
<code>write_bytes_sec_max</code> burst period. Only valid
when the <code>write_bytes_sec_max</code> is set.</dd><dt><code>total_iops_sec_max_length</code></dt><dd>The optional <code>total_iops_sec_max_length</code>
element is the maximum duration in seconds for the
<code>total_iops_sec_max</code> burst period. Only valid
when the <code>total_iops_sec_max</code> is set.</dd><dt><code>read_iops_sec_max_length</code></dt><dd>The optional <code>read_iops_sec_max_length</code>
element is the maximum duration in seconds for the
<code>read_iops_sec_max</code> burst period. Only valid
when the <code>read_iops_sec_max</code> is set.</dd><dt><code>write_iops_sec_max</code></dt><dd>The optional <code>write_iops_sec_max_length</code>
element is the maximum duration in seconds for the
<code>write_iops_sec_max</code> burst period. Only valid
when the <code>write_iops_sec_max</code> is set.
<p><span class="since">Throughput length since 2.4.0 and QEMU 2.6</span></p>
</dd></dl>
</dd>
<dt>
<code>driver</code>
</dt>
<dd>
The optional driver element allows specifying further details
related to the hypervisor driver used to provide the disk.
<span class="since">Since 0.1.8</span>
<ul><li>
If the hypervisor supports multiple backend drivers, then
the <code>name</code> attribute selects the primary
backend driver name, while the optional <code>type</code>
attribute provides the sub-type. For example, xen
supports a name of "tap", "tap2", "phy", or "file", with a
type of "aio", while qemu only supports a name of "qemu",
but multiple types including "raw", "bochs", "qcow2", and
"qed".
</li><li>
The optional <code>cache</code> attribute controls the
cache mechanism, possible values are "default", "none",
"writethrough", "writeback", "directsync" (like
"writethrough", but it bypasses the host page cache) and
"unsafe" (host may cache all disk io, and sync requests from
guest are ignored).
<span class="since">
Since 0.6.0,
"directsync" since 0.9.5,
"unsafe" since 0.9.7
</span>
</li><li>
The optional <code>error_policy</code> attribute controls
how the hypervisor will behave on a disk read or write
error, possible values are "stop", "report", "ignore", and
"enospace".<span class="since">Since 0.8.0, "report" since
0.9.7</span> The default is left to the discretion of the
hypervisor. There is also an
optional <code>rerror_policy</code> that controls behavior
for read errors only. <span class="since">Since
0.9.7</span>. If no rerror_policy is given, error_policy
is used for both read and write errors. If rerror_policy
is given, it overrides the <code>error_policy</code> for
read errors. Also note that "enospace" is not a valid
policy for read errors, so if <code>error_policy</code> is
set to "enospace" and no <code>rerror_policy</code> is
given, the read error policy will be left at its default.
</li><li>
The optional <code>io</code> attribute controls specific
policies on I/O; qemu guests support "threads" and
"native". <span class="since">Since 0.8.8</span>
</li><li>
The optional <code>ioeventfd</code> attribute allows users to
set <a href="https://patchwork.kernel.org/patch/43390/">
domain I/O asynchronous handling</a> for disk device.
The default is left to the discretion of the hypervisor.
Accepted values are "on" and "off". Enabling this allows
qemu to execute VM while a separate thread handles I/O.
Typically guests experiencing high system CPU utilization
during I/O will benefit from this. On the other hand,
on overloaded host it could increase guest I/O latency.
<span class="since">Since 0.9.3 (QEMU and KVM only)</span>
<b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</li><li>
The optional <code>event_idx</code> attribute controls
some aspects of device event processing. The value can be
either 'on' or 'off' - if it is on, it will reduce the
number of interrupts and exits for the guest. The default
is determined by QEMU; usually if the feature is
supported, default is on. In case there is a situation
where this behavior is suboptimal, this attribute provides
a way to force the feature off.
<span class="since">Since 0.9.5 (QEMU and KVM only)</span>
<b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</li><li>
The optional <code>copy_on_read</code> attribute controls
whether to copy read backing file into the image file. The
value can be either "on" or "off".
Copy-on-read avoids accessing the same backing file sectors
repeatedly and is useful when the backing file is over a slow
network. By default copy-on-read is off.
<span class="since">Since 0.9.10 (QEMU and KVM only)</span>
</li><li>
The optional <code>discard</code> attribute controls whether
discard requests (also known as "trim" or "unmap") are
ignored or passed to the filesystem. The value can be either
"unmap" (allow the discard request to be passed) or "ignore"
(ignore the discard request).
<span class="since">Since 1.0.6 (QEMU and KVM only)</span>
</li><li>
The optional <code>detect_zeroes</code> attribute controls whether
to detect zero write requests. The value can be "off", "on" or
"unmap". First two values turn the detection off and on,
respectively. The third value ("unmap") turns the detection on
and additionally tries to discard such areas from the image based
on the value of <code>discard</code> above (it will act as "on"
if <code>discard</code> is set to "ignore"). NB enabling the
detection is a compute intensive operation, but can save file
space and/or time on slow media.
<span class="since">Since 2.0.0</span>
</li><li>
The optional <code>iothread</code> attribute assigns the
disk to an IOThread as defined by the range for the domain
<a href="#elementsIOThreadsAllocation"><code>iothreads</code></a>
value. Multiple disks may be assigned to the same IOThread and
are numbered from 1 to the domain iothreads value. Available
for a disk device <code>target</code> configured to use "virtio"
<code>bus</code> and "pci" or "ccw" <code>address</code> types.
<span class="since">Since 1.2.8 (QEMU 2.1)</span>
</li><li>
The optional <code>queues</code> attribute specifies the number of
virt queues for virtio-blk. (<span class="since">Since 3.9.0</span>)
</li><li>
For virtio disks,
<a href="#elementsVirtio">Virtio-specific options</a> can also be
set. (<span class="since">Since 3.5.0</span>)
</li></ul>
</dd>
<dt>
<code>backenddomain</code>
</dt>
<dd>The optional <code>backenddomain</code> element allows specifying a
backend domain (aka driver domain) hosting the disk. Use the
<code>name</code> attribute to specify the backend domain name.
<span class="since">Since 1.2.13 (Xen only)</span>
</dd>
<dt>
<code>boot</code>
</dt>
<dd>Specifies that the disk is bootable. The <code>order</code>
attribute determines the order in which devices will be tried during
boot sequence. On the S390 architecture only the first boot device is
used. The optional <code>loadparm</code> attribute is an 8 character
string which can be queried by guests on S390 via sclp or diag 308.
Linux guests on S390 can use <code>loadparm</code> to select a boot
entry. <span class="since">Since 3.5.0</span>
The per-device <code>boot</code> elements cannot be used together
with general boot elements in
<a href="#elementsOSBIOS">BIOS bootloader</a> section.
<span class="since">Since 0.8.8</span>
</dd>
<dt>
<code>encryption</code>
</dt>
<dd>Starting with <span class="since">libvirt 3.9.0</span> the
<code>encryption</code> element is preferred to be a sub-element
of the <code>source</code> element. If present, specifies how the
volume is encrypted using "qcow". See the
<a href="formatstorageencryption.html">Storage Encryption</a> page
for more information.
</dd>
<dt>
<code>readonly</code>
</dt>
<dd>If present, this indicates the device cannot be modified by
the guest. For now, this is the default for disks with
attribute <code>device='cdrom'</code>.
</dd>
<dt>
<code>shareable</code>
</dt>
<dd>If present, this indicates the device is expected to be shared
between domains (assuming the hypervisor and OS support this),
which means that caching should be deactivated for that device.
</dd>
<dt>
<code>transient</code>
</dt>
<dd>If present, this indicates that changes to the device
contents should be reverted automatically when the guest
exits. With some hypervisors, marking a disk transient
prevents the domain from participating in migration or
snapshots. <span class="since">Since 0.9.5</span>
</dd>
<dt>
<code>serial</code>
</dt>
<dd>If present, this specify serial number of virtual hard drive.
For example, it may look
like <code><serial>WD-WMAP9A966149</serial></code>.
Not supported for scsi-block devices, that is those using
disk <code>type</code> 'block' using <code>device</code> 'lun'
on <code>bus</code> 'scsi'.
<span class="since">Since 0.7.1</span>
</dd>
<dt>
<code>wwn</code>
</dt>
<dd>If present, this element specifies the WWN (World Wide Name)
of a virtual hard disk or CD-ROM drive. It must be composed
of 16 hexadecimal digits.
<span class="since">Since 0.10.1</span>
</dd>
<dt>
<code>vendor</code>
</dt>
<dd>If present, this element specifies the vendor of a virtual hard
disk or CD-ROM device. It must not be longer than 8 printable
characters.
<span class="since">Since 1.0.1</span>
</dd>
<dt>
<code>product</code>
</dt>
<dd>If present, this element specifies the product of a virtual hard
disk or CD-ROM device. It must not be longer than 16 printable
characters.
<span class="since">Since 1.0.1</span>
</dd>
<dt>
<code>address</code>
</dt>
<dd>If present, the <code>address</code> element ties the disk
to a given slot of a controller (the
actual <code><controller></code> device can often be
inferred by libvirt, although it can
be <a href="#elementsControllers">explicitly specified</a>).
The <code>type</code> attribute is mandatory, and is typically
"pci" or "drive". For a "pci" controller, additional
attributes for <code>bus</code>, <code>slot</code>,
and <code>function</code> must be present, as well as
optional <code>domain</code> and <code>multifunction</code>.
Multifunction defaults to 'off'; any other value requires
QEMU 0.1.3 and <span class="since">libvirt 0.9.7</span>. For a
"drive" controller, additional attributes
<code>controller</code>, <code>bus</code>, <code>target</code>
(<span class="since">libvirt 0.9.11</span>), and <code>unit</code>
are available, each defaulting to 0.
</dd>
<dt>
<code>auth</code>
</dt>
<dd>Starting with <span class="since">libvirt 3.9.0</span> the
<code>auth</code> element is preferred to be a sub-element of
the <code>source</code> element. The element is still read and
managed as a <code>disk</code> sub-element. It is invalid to use
<code>auth</code> as both a sub-element of <code>disk</code>
and <code>source</code>. The <code>auth</code> element was
introduced as a <code>disk</code> sub-element in
<span class="since">libvirt 0.9.7.</span>
</dd>
<dt>
<code>geometry</code>
</dt>
<dd>The optional <code>geometry</code> element provides the
ability to override geometry settings. This mostly useful for
S390 DASD-disks or older DOS-disks. <span class="since">0.10.0</span>
<dl><dt><code>cyls</code></dt><dd>The <code>cyls</code> attribute is the
number of cylinders. </dd><dt><code>heads</code></dt><dd>The <code>heads</code> attribute is the
number of heads. </dd><dt><code>secs</code></dt><dd>The <code>secs</code> attribute is the
number of sectors per track. </dd><dt><code>trans</code></dt><dd>The optional <code>trans</code> attribute is the
BIOS-Translation-Modus (none, lba or auto)</dd></dl>
</dd>
<dt>
<code>blockio</code>
</dt>
<dd>If present, the <code>blockio</code> element allows
to override any of the block device properties listed below.
<span class="since">Since 0.10.2 (QEMU and KVM)</span>
<dl><dt><code>logical_block_size</code></dt><dd>The logical block size the disk will report to the guest
OS. For Linux this would be the value returned by the
BLKSSZGET ioctl and describes the smallest units for disk
I/O.
</dd><dt><code>physical_block_size</code></dt><dd>The physical block size the disk will report to the guest
OS. For Linux this would be the value returned by the
BLKPBSZGET ioctl and describes the disk's hardware sector
size which can be relevant for the alignment of disk data.
</dd></dl>
</dd>
</dl>
<h4>
<a id="elementsFilesystems">Filesystems</a>
<a class="headerlink" href="#elementsFilesystems" title="Permalink to this headline">¶</a>
</h4>
<p>
A directory on the host that can be accessed directly from the guest.
<span class="since">since 0.3.3, since 0.8.5 for QEMU/KVM</span>
</p>
<pre>
...
<devices>
<filesystem type='template'>
<source name='my-vm-template'/>
<target dir='/'/>
</filesystem>
<filesystem type='mount' accessmode='passthrough'>
<driver type='path' wrpolicy='immediate'/>
<source dir='/export/to/guest'/>
<target dir='/import/from/host'/>
<readonly/>
</filesystem>
<filesystem type='file' accessmode='passthrough'>
<driver name='loop' type='raw'/>
<driver type='path' wrpolicy='immediate'/>
<source file='/export/to/guest.img'/>
<target dir='/import/from/host'/>
<readonly/>
</filesystem>
...
</devices>
...</pre>
<dl>
<dt>
<code>filesystem</code>
</dt>
<dd>
The filesystem attribute <code>type</code> specifies the type of the
<code>source</code>. The possible values are:
<dl><dt><code>mount</code></dt><dd>
A host directory to mount in the guest. Used by LXC,
OpenVZ <span class="since">(since 0.6.2)</span>
and QEMU/KVM <span class="since">(since 0.8.5)</span>.
This is the default <code>type</code> if one is not specified.
This mode also has an optional
sub-element <code>driver</code>, with an
attribute <code>type='path'</code>
or <code>type='handle'</code> <span class="since">(since
0.9.7)</span>. The driver block has an optional attribute
<code>wrpolicy</code> that further controls interaction with
the host page cache; omitting the attribute gives default behavior,
while the value <code>immediate</code> means that a host writeback
is immediately triggered for all pages touched during a guest file
write operation <span class="since">(since 0.9.10)</span>.
</dd><dt><code>template</code></dt><dd>
OpenVZ filesystem template. Only used by OpenVZ driver.
</dd><dt><code>file</code></dt><dd>
A host file will be treated as an image and mounted in
the guest. The filesystem format will be autodetected.
Only used by LXC driver.
</dd><dt><code>block</code></dt><dd>
A host block device to mount in the guest. The filesystem
format will be autodetected. Only used by LXC driver
<span class="since">(since 0.9.5)</span>.
</dd><dt><code>ram</code></dt><dd>
An in-memory filesystem, using memory from the host OS.
The source element has a single attribute <code>usage</code>
which gives the memory usage limit in KiB, unless units
are specified by the <code>units</code> attribute. Only used
by LXC driver.
<span class="since"> (since 0.9.13)</span></dd><dt><code>bind</code></dt><dd>
A directory inside the guest will be bound to another
directory inside the guest. Only used by LXC driver
<span class="since"> (since 0.9.13)</span></dd></dl>
The filesystem block has an optional attribute <code>accessmode</code>
which specifies the security mode for accessing the source
<span class="since">(since 0.8.5)</span>. Currently this only works
with <code>type='mount'</code> for the QEMU/KVM driver. The possible
values are:
<dl><dt><code>passthrough</code></dt><dd>
The <code>source</code> is accessed with the permissions of the
user inside the guest. This is the default <code>accessmode</code> if
one is not specified.
<a href="http://lists.gnu.org/archive/html/qemu-devel/2010-05/msg02673.html">More info</a>
</dd><dt><code>mapped</code></dt><dd>
The <code>source</code> is accessed with the permissions of the
hypervisor (QEMU process).
<a href="http://lists.gnu.org/archive/html/qemu-devel/2010-05/msg02673.html">More info</a>
</dd><dt><code>squash</code></dt><dd>
Similar to 'passthrough', the exception is that failure of
privileged operations like 'chown' are ignored. This makes a
passthrough-like mode usable for people who run the hypervisor
as non-root.
<a href="http://lists.gnu.org/archive/html/qemu-devel/2010-09/msg00121.html">More info</a>
</dd></dl>
</dd>
<dt>
<code>driver</code>
</dt>
<dd>
The optional driver element allows specifying further details
related to the hypervisor driver used to provide the filesystem.
<span class="since">Since 1.0.6</span>
<ul><li>
If the hypervisor supports multiple backend drivers, then
the <code>type</code> attribute selects the primary
backend driver name, while the <code>format</code>
attribute provides the format type. For example, LXC
supports a type of "loop", with a format of "raw" or
"nbd" with any format. QEMU supports a type of "path"
or "handle", but no formats. Virtuozzo driver supports
a type of "ploop" with a format of "ploop".
</li><li>
For virtio-backed devices,
<a href="#elementsVirtio">Virtio-specific options</a> can also be
set. (<span class="since">Since 3.5.0</span>)
</li></ul>
</dd>
<dt>
<code>source</code>
</dt>
<dd>
The resource on the host that is being accessed in the guest. The
<code>name</code> attribute must be used with
<code>type='template'</code>, and the <code>dir</code> attribute must
be used with <code>type='mount'</code>. The <code>usage</code> attribute
is used with <code>type='ram'</code> to set the memory limit in KiB,
unless units are specified by the <code>units</code> attribute.
</dd>
<dt>
<code>target</code>
</dt>
<dd>
Where the <code>source</code> can be accessed in the guest. For
most drivers this is an automatic mount point, but for QEMU/KVM
this is merely an arbitrary string tag that is exported to the
guest as a hint for where to mount.
</dd>
<dt>
<code>readonly</code>
</dt>
<dd>
Enables exporting filesystem as a readonly mount for guest, by
default read-write access is given (currently only works for
QEMU/KVM driver).
</dd>
<dt>
<code>space_hard_limit</code>
</dt>
<dd>
Maximum space available to this guest's filesystem.
<span class="since">Since 0.9.13</span>
</dd>
<dt>
<code>space_soft_limit</code>
</dt>
<dd>
Maximum space available to this guest's filesystem. The container is
permitted to exceed its soft limits for a grace period of time. Afterwards the
hard limit is enforced.
<span class="since">Since 0.9.13</span>
</dd>
</dl>
<h4>
<a id="elementsAddress">Device Addresses</a>
<a class="headerlink" href="#elementsAddress" title="Permalink to this headline">¶</a>
</h4>
<p>
Many devices have an optional <code><address></code>
sub-element to describe where the device is placed on the
virtual bus presented to the guest. If an address (or any
optional attribute within an address) is omitted on
input, libvirt will generate an appropriate address; but an
explicit address is required if more control over layout is
required. See below for device examples including an address
element.
</p>
<p>
Every address has a mandatory attribute <code>type</code> that
describes which bus the device is on. The choice of which
address to use for a given device is constrained in part by the
device and the architecture of the guest. For example,
a <code><disk></code> device
uses <code>type='drive'</code>, while
a <code><console></code> device would
use <code>type='pci'</code> on i686 or x86_64 guests,
or <code>type='spapr-vio'</code> on PowerPC64 pseries guests.
Each address type has further optional attributes that control
where on the bus the device will be placed:
</p>
<dl>
<dt>
<code>pci</code>
</dt>
<dd>PCI addresses have the following additional
attributes: <code>domain</code> (a 2-byte hex integer, not
currently used by qemu), <code>bus</code> (a hex value between
0 and 0xff, inclusive), <code>slot</code> (a hex value between
0x0 and 0x1f, inclusive), and <code>function</code> (a value
between 0 and 7, inclusive). Also available is
the <code>multifunction</code> attribute, which controls
turning on the multifunction bit for a particular
slot/function in the PCI control register
(<span class="since">since 0.9.7, requires QEMU
0.13</span>). <code>multifunction</code> defaults to 'off',
but should be set to 'on' for function 0 of a slot that will
have multiple functions used.
(<span class="since">Since 4.10.0</span>), PCI address extensions
depending on the architecture are supported. For example, PCI
addresses for S390 guests will have a <code>zpci</code> child
element, with two attributes: <code>uid</code> (a hex value
between 0x0001 and 0xffff, inclusive), and <code>fid</code> (a
hex value between 0x00000000 and 0xffffffff, inclusive) used by
PCI devices on S390 for User-defined Identifiers and Function
Identifiers.<br/>
<span class="since">Since 1.3.5</span>, some hypervisor
drivers may accept an <code><address type='pci'/></code>
element with no other attributes as an explicit request to
assign a PCI address for the device rather than some other
type of address that may also be appropriate for that same
device (e.g. virtio-mmio).
</dd>
<dt>
<code>drive</code>
</dt>
<dd>Drive addresses have the following additional
attributes: <code>controller</code> (a 2-digit controller
number), <code>bus</code> (a 2-digit bus number),
<code>target</code> (a 2-digit target number),
and <code>unit</code> (a 2-digit unit number on the bus).
</dd>
<dt>
<code>virtio-serial</code>
</dt>
<dd>Each virtio-serial address has the following additional
attributes: <code>controller</code> (a 2-digit controller
number), <code>bus</code> (a 2-digit bus number),
and <code>slot</code> (a 2-digit slot within the bus).
</dd>
<dt>
<code>ccid</code>
</dt>
<dd>A CCID address, for smart-cards, has the following
additional attributes: <code>bus</code> (a 2-digit bus
number), and <code>slot</code> attribute (a 2-digit slot
within the bus). <span class="since">Since 0.8.8.</span>
</dd>
<dt>
<code>usb</code>
</dt>
<dd>USB addresses have the following additional
attributes: <code>bus</code> (a hex value between 0 and 0xfff,
inclusive), and <code>port</code> (a dotted notation of up to
four octets, such as 1.2 or 2.1.3.1).
</dd>
<dt>
<code>spapr-vio</code>
</dt>
<dd>On PowerPC pseries guests, devices can be assigned to the
SPAPR-VIO bus. It has a flat 64-bit address space; by
convention, devices are generally assigned at a non-zero
multiple of 0x1000, but other addresses are valid and
permitted by libvirt. Each address has the following
additional attribute: <code>reg</code> (the hex value address
of the starting register). <span class="since">Since
0.9.9.</span>
</dd>
<dt>
<code>ccw</code>
</dt>
<dd>S390 guests with a <code>machine</code> value of
s390-ccw-virtio use the native CCW bus for I/O devices.
CCW bus addresses have the following additional attributes:
<code>cssid</code> (a hex value between 0 and 0xfe, inclusive),
<code>ssid</code> (a value between 0 and 3, inclusive) and
<code>devno</code> (a hex value between 0 and 0xffff, inclusive).
Partially specified bus addresses are not allowed.
If omitted, libvirt will assign a free bus address with
cssid=0xfe and ssid=0. Virtio-ccw devices must have their cssid
set to 0xfe.
<span class="since">Since 1.0.4</span>
</dd>
<dt>
<code>virtio-mmio</code>
</dt>
<dd>This places the device on the virtio-mmio transport, which is
currently only available for some <code>armv7l</code> and
<code>aarch64</code> virtual machines. virtio-mmio addresses
do not have any additional attributes.
<span class="since">Since 1.1.3</span><br/>
If the guest architecture is <code>aarch64</code> and the machine
type is <code>virt</code>, libvirt will automatically assign PCI
addresses to devices; however, the presence of a single device
with virtio-mmio address in the guest configuration will cause
libvirt to assign virtio-mmio addresses to all further devices.
<span class="since">Since 3.0.0</span>
</dd>
<dt>
<code>isa</code>
</dt>
<dd>ISA addresses have the following additional
attributes: <code>iobase</code> and <code>irq</code>.
<span class="since">Since 1.2.1</span>
</dd>
</dl>
<h4>
<a id="elementsVirtio">Virtio-related options</a>
<a class="headerlink" href="#elementsVirtio" title="Permalink to this headline">¶</a>
</h4>
<p>
QEMU's virtio devices have some attributes related to the virtio transport under
the <code>driver</code> element:
The <code>iommu</code> attribute enables the use of emulated IOMMU
by the device. The attribute <code>ats</code> controls the Address
Translation Service support for PCIe devices. This is needed to make use
of IOTLB support (see <a href="#elementsIommu">IOMMU device</a>).
Possible values are <code>on</code> or <code>off</code>.
<span class="since">Since 3.5.0</span>
</p>
<h4>
<a id="elementsControllers">Controllers</a>
<a class="headerlink" href="#elementsControllers" title="Permalink to this headline">¶</a>
</h4>
<p>
Depending on the guest architecture, some device buses can
appear more than once, with a group of virtual devices tied to a
virtual controller. Normally, libvirt can automatically infer such
controllers without requiring explicit XML markup, but sometimes
it is necessary to provide an explicit controller element, notably
when planning the <a href="pci-hotplug.html">PCI topology</a>
for guests where device hotplug is expected.
</p>
<pre>
...
<devices>
<controller type='ide' index='0'/>
<controller type='virtio-serial' index='0' ports='16' vectors='4'/>
<controller type='virtio-serial' index='1'>
<address type='pci' domain='0x0000' bus='0x00' slot='0x0a' function='0x0'/>
</controller>
<controller type='scsi' index='0' model='virtio-scsi'>
<driver iothread='4'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/>
</controller>
...
</devices>
...</pre>
<p>
Each controller has a mandatory attribute <code>type</code>,
which must be one of 'ide', 'fdc', 'scsi', 'sata', 'usb',
'ccid', 'virtio-serial' or 'pci', and a mandatory
attribute <code>index</code> which is the decimal integer
describing in which order the bus controller is encountered (for
use in <code>controller</code> attributes of
<code><address></code> elements).
<span class="since">Since 1.3.5</span> the index is optional; if
not specified, it will be auto-assigned to be the lowest unused
index for the given controller type. Some controller types have
additional attributes that control specific features, such as:
</p>
<dl>
<dt>
<code>virtio-serial</code>
</dt>
<dd>The <code>virtio-serial</code> controller has two additional
optional attributes <code>ports</code> and <code>vectors</code>,
which control how many devices can be connected through the
controller.</dd>
<dt>
<code>scsi</code>
</dt>
<dd>A <code>scsi</code> controller has an optional attribute
<code>model</code>, which is one of 'auto', 'buslogic', 'ibmvscsi',
'lsilogic', 'lsisas1068', 'lsisas1078', 'virtio-scsi' or
'vmpvscsi'.</dd>
<dt>
<code>usb</code>
</dt>
<dd>A <code>usb</code> controller has an optional attribute
<code>model</code>, which is one of "piix3-uhci", "piix4-uhci",
"ehci", "ich9-ehci1", "ich9-uhci1", "ich9-uhci2", "ich9-uhci3",
"vt82c686b-uhci", "pci-ohci", "nec-xhci", "qusb1" (xen pvusb
with qemu backend, version 1.1), "qusb2" (xen pvusb with qemu
backend, version 2.0) or "qemu-xhci". Additionally,
<span class="since">since 0.10.0</span>, if the USB bus needs to
be explicitly disabled for the guest, <code>model='none'</code>
may be used. <span class="since">Since 1.0.5</span>, no default
USB controller will be built on s390.
<span class="since">Since 1.3.5</span>, USB controllers accept a
<code>ports</code> attribute to configure how many devices can be
connected to the controller.</dd>
<dt>
<code>ide</code>
</dt>
<dd><span class="since">Since 3.10.0</span> for the vbox driver, the
<code>ide</code> controller has an optional attribute
<code>model</code>, which is one of "piix3", "piix4" or "ich6".</dd>
</dl>
<p>
Note: The PowerPC64 "spapr-vio" addresses do not have an
associated controller.
</p>
<p>
For controllers that are themselves devices on a PCI or USB bus,
an optional sub-element <code><address></code> can specify
the exact relationship of the controller to its master bus, with
semantics <a href="#elementsAddress">given above</a>.
</p>
<p>
An optional sub-element <code>driver</code> can specify the driver
specific options:
</p>
<dl>
<dt>
<code>queues</code>
</dt>
<dd>
The optional <code>queues</code> attribute specifies the number of
queues for the controller. For best performance, it's recommended to
specify a value matching the number of vCPUs.
<span class="since">Since 1.0.5 (QEMU and KVM only)</span>
</dd>
<dt>
<code>cmd_per_lun</code>
</dt>
<dd>
The optional <code>cmd_per_lun</code> attribute specifies the maximum
number of commands that can be queued on devices controlled by the
host.
<span class="since">Since 1.2.7 (QEMU and KVM only)</span>
</dd>
<dt>
<code>max_sectors</code>
</dt>
<dd>
The optional <code>max_sectors</code> attribute specifies the maximum
amount of data in bytes that will be transferred to or from the device
in a single command. The transfer length is measured in sectors, where
a sector is 512 bytes.
<span class="since">Since 1.2.7 (QEMU and KVM only)</span>
</dd>
<dt>
<code>ioeventfd</code>
</dt>
<dd>
The optional <code>ioeventfd</code> attribute specifies
whether the controller should use
<a href="https://patchwork.kernel.org/patch/43390/">
I/O asynchronous handling</a> or not. Accepted values are
"on" and "off". <span class="since">Since 1.2.18</span>
</dd>
<dt>
<code>iothread</code>
</dt>
<dd>
Supported for controller type <code>scsi</code> using model
<code>virtio-scsi</code> for <code>address</code> types
<code>pci</code> and <code>ccw</code>
<span class="since">since 1.3.5 (QEMU 2.4)</span>.
The optional <code>iothread</code> attribute assigns the controller
to an IOThread as defined by the range for the domain
<a href="#elementsIOThreadsAllocation"><code>iothreads</code></a>
value. Each SCSI <code>disk</code> assigned to use the specified
<code>controller</code> will utilize the same IOThread. If a specific
IOThread is desired for a specific SCSI <code>disk</code>, then
multiple controllers must be defined each having a specific
<code>iothread</code> value. The <code>iothread</code> value
must be within the range 1 to the domain iothreads value.
</dd>
<dt>virtio options</dt>
<dd>
For virtio controllers,
<a href="#elementsVirtio">Virtio-specific options</a> can also be
set. (<span class="since">Since 3.5.0</span>)
</dd>
</dl>
<p>
USB companion controllers have an optional
sub-element <code><master></code> to specify the exact
relationship of the companion to its master controller.
A companion controller is on the same bus as its master, so
the companion <code>index</code> value should be equal.
Not all controller models can be used as companion controllers
and libvirt might provide some sensible defaults (settings
of <code>master startport</code> and <code>function</code> of an
address) for some particular models.
Preferred companion controllers are <code>ich-uhci[123]</code>.
</p>
<pre>
...
<devices>
<controller type='usb' index='0' model='ich9-ehci1'>
<address type='pci' domain='0' bus='0' slot='4' function='7'/>
</controller>
<controller type='usb' index='0' model='ich9-uhci1'>
<master startport='0'/>
<address type='pci' domain='0' bus='0' slot='4' function='0' multifunction='on'/>
</controller>
...
</devices>
...</pre>
<p>
PCI controllers have an optional <code>model</code> attribute; possible
values for this attribute are
</p>
<ul>
<li><code>pci-root</code>, <code>pci-bridge</code>
(<span class="since">since 1.0.5</span>)
</li>
<li><code>pcie-root</code>, <code>dmi-to-pci-bridge</code>
(<span class="since">since 1.1.2</span>)
</li>
<li><code>pcie-root-port</code>, <code>pcie-switch-upstream-port</code>,
<code>pcie-switch-downstream-port</code>
(<span class="since">since 1.2.19</span>)
</li>
<li><code>pci-expander-bus</code>, <code>pcie-expander-bus</code>
(<span class="since">since 1.3.4</span>)
</li>
<li><code>pcie-to-pci-bridge</code>
(<span class="since">since 4.3.0</span>)
</li>
</ul>
<p>
The root controllers (<code>pci-root</code>
and <code>pcie-root</code>) have an
optional <code>pcihole64</code> element specifying how big (in
kilobytes, or in the unit specified by <code>pcihole64</code>'s
<code>unit</code> attribute) the 64-bit PCI hole should be. Some guests (like
Windows XP or Windows Server 2003) might crash when QEMU and Seabios
are recent enough to support 64-bit PCI holes, unless this is disabled
(set to 0). <span class="since">Since 1.1.2 (QEMU only)</span>
</p>
<p>
PCI controllers also have an optional
subelement <code><model></code> with an attribute
<code>name</code>. The name attribute holds the name of the
specific device that qemu is emulating (e.g. "i82801b11-bridge")
rather than simply the class of device ("dmi-to-pci-bridge",
"pci-bridge"), which is set in the controller element's
model <b>attribute</b>. In almost all cases, you should not
manually add a <code><model></code> subelement to a
controller, nor should you modify one that is automatically
generated by libvirt. <span class="since">Since 1.2.19 (QEMU
only).</span>
</p>
<p>
PCI controllers also have an optional
subelement <code><target></code> with the attributes and
subelements listed below. These are configurable items that 1)
are visible to the guest OS so must be preserved for guest ABI
compatibility, and 2) are usually left to default values or
derived automatically by libvirt. In almost all cases, you
should not manually add a <code><target></code> subelement
to a controller, nor should you modify the values in the those
that are automatically generated by
libvirt. <span class="since">Since 1.2.19 (QEMU only).</span>
</p>
<dl>
<dt>
<code>chassisNr</code>
</dt>
<dd>
PCI controllers that have attribute model="pci-bridge", can
also have a <code>chassisNr</code> attribute in
the <code><target></code> subelement, which is used to
control QEMU's "chassis_nr" option for the pci-bridge device
(normally libvirt automatically sets this to the same value as
the index attribute of the pci controller). If set, chassisNr
must be between 1 and 255.
</dd>
<dt>
<code>chassis</code>
</dt>
<dd>
pcie-root-port and pcie-switch-downstream-port controllers can
also have a <code>chassis</code> attribute in
the <code><target></code> subelement, which is used to
set the controller's "chassis" configuration value, which is
visible to the virtual machine. If set, chassis must be
between 0 and 255.
</dd>
<dt>
<code>port</code>
</dt>
<dd>
pcie-root-port and pcie-switch-downstream-port controllers can
also have a <code>port</code> attribute in
the <code><target></code> subelement, which
is used to set the controller's "port" configuration value,
which is visible to the virtual machine. If set, port must be
between 0 and 255.
</dd>
<dt>
<code>busNr</code>
</dt>
<dd>
pci-expander-bus and pcie-expander-bus controllers can have an
optional <code>busNr</code> attribute (1-254). This will be
the bus number of the new bus; All bus numbers between that
specified and 255 will be available only for assignment to
PCI/PCIe controllers plugged into the hierarchy starting with
this expander bus, and bus numbers less than the specified
value will be available to the next lower expander-bus (or the
root-bus if there are no lower expander buses). If you do not
specify a busNumber, libvirt will find the lowest existing
busNumber in all other expander buses (or use 256 if there are
no others) and auto-assign the busNr of that found bus - 2,
which provides one bus number for the pci-expander-bus and one
for the pci-bridge that is automatically attached to it (if
you plan on adding more pci-bridges to the hierarchy of the
bus, you should manually set busNr to a lower value).
<p>
A similar algorithm is used for automatically determining
the busNr attribute for pcie-expander-bus, but since the
pcie-expander-bus doesn't have any built-in pci-bridge, the
2nd bus-number is just being reserved for the pcie-root-port
that must necessarily be connected to the bus in order to
actually plug in an endpoint device. If you intend to plug
multiple devices into a pcie-expander-bus, you must connect
a pcie-switch-upstream-port to the pcie-root-port that is
plugged into the pcie-expander-bus, and multiple
pcie-switch-downstream-ports to the
pcie-switch-upstream-port, and of course for this to work
properly, you will need to decrease the pcie-expander-bus'
busNr accordingly so that there are enough unused bus
numbers above it to accommodate giving out one bus number for
the upstream-port and one for each downstream-port (in
addition to the pcie-root-port and the pcie-expander-bus
itself).
</p>
</dd>
<dt>
<code>node</code>
</dt>
<dd>
Some PCI controllers (<code>pci-expander-bus</code> for the pc
machine type, <code>pcie-expander-bus</code> for the q35 machine
type and, <span class="since">since 3.6.0</span>,
<code>pci-root</code> for the pseries machine type) can have an
optional <code><node></code> subelement within
the <code><target></code> subelement, which is used to
set the NUMA node reported to the guest OS for that bus - the
guest OS will then know that all devices on that bus are a
part of the specified NUMA node (it is up to the user of the
libvirt API to attach host devices to the correct
pci-expander-bus when assigning them to the domain).
</dd>
<dt>
<code>index</code>
</dt>
<dd>
pci-root controllers for pSeries guests use this attribute to
record the order they will show up in the guest.
<span class="since">Since 3.6.0</span>
</dd>
</dl>
<p>
For machine types which provide an implicit PCI bus, the pci-root
controller with index=0 is auto-added and required to use PCI devices.
pci-root has no address.
PCI bridges are auto-added if there are too many devices to fit on
the one bus provided by pci-root, or a PCI bus number greater than zero
was specified.
PCI bridges can also be specified manually, but their addresses should
only refer to PCI buses provided by already specified PCI controllers.
Leaving gaps in the PCI controller indexes might lead to an invalid
configuration.
</p>
<pre>
...
<devices>
<controller type='pci' index='0' model='pci-root'/>
<controller type='pci' index='1' model='pci-bridge'>
<address type='pci' domain='0' bus='0' slot='5' function='0' multifunction='off'/>
</controller>
</devices>
...</pre>
<p>
For machine types which provide an implicit PCI Express (PCIe)
bus (for example, the machine types based on the Q35 chipset),
the pcie-root controller with index=0 is auto-added to the
domain's configuration. pcie-root has also no address, provides
31 slots (numbered 1-31) that can be used to attach PCIe or PCI
devices (although libvirt will never auto-assign a PCI device to
a PCIe slot, it will allow manual specification of such an
assignment). Devices connected to pcie-root cannot be
hotplugged. If traditional PCI devices are present in the guest
configuration, a <code>pcie-to-pci-bridge</code> controller will
automatically be added: this controller, which plugs into a
<code>pcie-root-port</code>, provides 31 usable PCI slots (1-31) with
hotplug support (<span class="since">since 4.3.0</span>). If the QEMU
binary doesn't support the corresponding device, then a
<code>dmi-to-pci-bridge</code> controller will be added instead,
usually at the defacto standard location of slot=0x1e. A
dmi-to-pci-bridge controller plugs into a PCIe slot (as provided
by pcie-root), and itself provides 31 standard PCI slots (which
also do not support device hotplug). In order to have
hot-pluggable PCI slots in the guest system, a pci-bridge
controller will also be automatically created and connected to
one of the slots of the auto-created dmi-to-pci-bridge
controller; all guest PCI devices with addresses that are
auto-determined by libvirt will be placed on this pci-bridge
device. (<span class="since">since 1.1.2</span>).
</p>
<p>
Domains with an implicit pcie-root can also add controllers
with <code>model='pcie-root-port'</code>,
<code>model='pcie-switch-upstream-port'</code>,
and <code>model='pcie-switch-downstream-port'</code>. pcie-root-port
is a simple type of bridge device that can connect only to one
of the 31 slots on the pcie-root bus on its upstream side, and
makes a single (PCIe, hotpluggable) port available on the
downstream side (at slot='0'). pcie-root-port can be used to
provide a single slot to later hotplug a PCIe device (but is not
itself hotpluggable - it must be in the configuration when the
domain is started).
(<span class="since">since 1.2.19</span>)
</p>
<p>
pcie-switch-upstream-port is a more flexible (but also more
complex) device that can only plug into a pcie-root-port or
pcie-switch-downstream-port on the upstream side (and only
before the domain is started - it is not hot-pluggable), and
provides 32 ports on the downstream side (slot='0' - slot='31')
that accept only pcie-switch-downstream-port devices; each
pcie-switch-downstream-port device can only plug into a
pcie-switch-upstream-port on its upstream side (again, not
hot-pluggable), and on its downstream side provides a single
hotpluggable pcie port that can accept any standard pci or pcie
device (or another pcie-switch-upstream-port), i.e. identical in
function to a pcie-root-port. (<span class="since">since
1.2.19</span>)
</p>
<pre>
...
<devices>
<controller type='pci' index='0' model='pcie-root'/>
<controller type='pci' index='1' model='dmi-to-pci-bridge'>
<address type='pci' domain='0' bus='0' slot='0xe' function='0'/>
</controller>
<controller type='pci' index='2' model='pci-bridge'>
<address type='pci' domain='0' bus='1' slot='1' function='0'/>
</controller>
</devices>
...</pre>
<h4>
<a id="elementsLease">Device leases</a>
<a class="headerlink" href="#elementsLease" title="Permalink to this headline">¶</a>
</h4>
<p>
When using a lock manager, it may be desirable to record device leases
against a VM. The lock manager will ensure the VM won't start unless
the leases can be acquired.
</p>
<pre>
...
<devices>
...
<lease>
<lockspace>somearea</lockspace>
<key>somekey</key>
<target path='/some/lease/path' offset='1024'/>
</lease>
...
</devices>
...</pre>
<dl>
<dt>
<code>lockspace</code>
</dt>
<dd>This is an arbitrary string, identifying the lockspace
within which the key is held. Lock managers may impose
extra restrictions on the format, or length of the lockspace
name.</dd>
<dt>
<code>key</code>
</dt>
<dd>This is an arbitrary string, uniquely identifying the
lease to be acquired. Lock managers may impose extra
restrictions on the format, or length of the key.
</dd>
<dt>
<code>target</code>
</dt>
<dd>This is the fully qualified path of the file associated
with the lockspace. The offset specifies where the lease
is stored within the file. If the lock manager does not
require an offset, just pass 0.
</dd>
</dl>
<h4>
<a id="elementsHostDev">Host device assignment</a>
<a class="headerlink" href="#elementsHostDev" title="Permalink to this headline">¶</a>
</h4>
<h5>
<a id="elementsHostDevSubsys">USB / PCI / SCSI devices</a>
<a class="headerlink" href="#elementsHostDevSubsys" title="Permalink to this headline">¶</a>
</h5>
<p>
USB, PCI and SCSI devices attached to the host can be passed through
to the guest using the <code>hostdev</code> element.
<span class="since">since after 0.4.4 for USB, 0.6.0 for PCI (KVM only)
and 1.0.6 for SCSI (KVM only)</span>:
</p>
<pre>
...
<devices>
<hostdev mode='subsystem' type='usb'>
<source startupPolicy='optional'>
<vendor id='0x1234'/>
<product id='0xbeef'/>
</source>
<boot order='2'/>
</hostdev>
</devices>
...</pre>
<p>or:</p>
<pre>
...
<devices>
<hostdev mode='subsystem' type='pci' managed='yes'>
<source>
<address domain='0x0000' bus='0x06' slot='0x02' function='0x0'/>
</source>
<boot order='1'/>
<rom bar='on' file='/etc/fake/boot.bin'/>
</hostdev>
</devices>
...</pre>
<p>or:</p>
<pre>
...
<devices>
<hostdev mode='subsystem' type='scsi' sgio='filtered' rawio='yes'>
<source>
<adapter name='scsi_host0'/>
<address bus='0' target='0' unit='0'/>
</source>
<readonly/>
<address type='drive' controller='0' bus='0' target='0' unit='0'/>
</hostdev>
</devices>
...</pre>
<p>or:</p>
<pre>
...
<devices>
<hostdev mode='subsystem' type='scsi'>
<source protocol='iscsi' name='iqn.2014-08.com.example:iscsi-nopool/1'>
<host name='example.com' port='3260'/>
<auth username='myuser'>
<secret type='iscsi' usage='libvirtiscsi'/>
</auth>
</source>
<address type='drive' controller='0' bus='0' target='0' unit='0'/>
</hostdev>
</devices>
...</pre>
<p>or:</p>
<pre>
...
<devices>
<hostdev mode='subsystem' type='scsi_host'>
<source protocol='vhost' wwpn='naa.50014057667280d8'/>
</hostdev>
</devices>
...</pre>
<p>or:</p>
<pre>
...
<devices>
<hostdev mode='subsystem' type='mdev' model='vfio-pci'>
<source>
<address uuid='c2177883-f1bb-47f0-914d-32a22e3a8804'/>
</source>
</hostdev>
<hostdev mode='subsystem' type='mdev' model='vfio-ccw'>
<source>
<address uuid='9063cba3-ecef-47b6-abcf-3fef4fdcad85'/>
</source>
<address type='ccw' cssid='0xfe' ssid='0x0' devno='0x0001'/>
</hostdev>
</devices>
...</pre>
<dl>
<dt>
<code>hostdev</code>
</dt>
<dd>The <code>hostdev</code> element is the main container for describing
host devices. For each device, the <code>mode</code> is always
"subsystem" and the <code>type</code> is one of the following values
with additional attributes noted.
<dl><dt><code>usb</code></dt><dd>USB devices are detached from the host on guest startup
and reattached after the guest exits or the device is
hot-unplugged.
</dd><dt><code>pci</code></dt><dd>For PCI devices, when <code>managed</code> is "yes" it is
detached from the host before being passed on to the guest
and reattached to the host after the guest exits. If
<code>managed</code> is omitted or "no", the user is
responsible to call <code>virNodeDeviceDetachFlags</code>
(or <code>virsh nodedev-detach</code> before starting the guest
or hot-plugging the device and <code>virNodeDeviceReAttach</code>
(or <code>virsh nodedev-reattach</code>) after hot-unplug or
stopping the guest.
</dd><dt><code>scsi</code></dt><dd>For SCSI devices, user is responsible to make sure the device
is not used by host. If supported by the hypervisor and OS, the
optional <code>sgio</code> (<span class="since">since 1.0.6</span>)
attribute indicates whether unprivileged SG_IO commands are
filtered for the disk. Valid settings are "filtered" or
"unfiltered", where the default is "filtered".
The optional <code>rawio</code>
(<span class="since">since 1.2.9</span>) attribute indicates
whether the lun needs the rawio capability. Valid settings are
"yes" or "no". See the rawio description within the
<a href="#elementsDisks">disk</a> section.
If a disk lun in the domain already has the rawio capability,
then this setting not required.
</dd><dt><code>scsi_host</code></dt><dd><span class="since">since 2.5.0</span>For SCSI devices, user
is responsible to make sure the device is not used by host. This
<code>type</code> passes all LUNs presented by a single HBA to
the guest.
</dd><dt><code>mdev</code></dt><dd>For mediated devices (<span class="since">Since 3.2.0</span>)
the <code>model</code> attribute specifies the device API which
determines how the host's vfio driver will expose the device to the
guest. Currently, <code>model='vfio-pci'</code>,
<code>model='vfio-ccw'</code> (<span class="since">Since 4.4.0</span>)
and <code>model='vfio-ap'</code> (<span class="since">Since 4.9.0</span>)
is supported. <a href="drvnodedev.html#MDEV">MDEV</a> section
provides more information about mediated devices as well as how to
create mediated devices on the host.
<span class="since">Since 4.6.0 (QEMU 2.12)</span> an optional
<code>display</code> attribute may be used to enable or disable
support for an accelerated remote desktop backed by a mediated
device (such as NVIDIA vGPU or Intel GVT-g) as an alternative to
emulated <a href="#elementsVideo">video devices</a>. This attribute
is limited to <code>model='vfio-pci'</code> only. Supported values
are either <code>on</code> or <code>off</code> (default is 'off').
It is required to use a
<a href="#elementsGraphics">graphical framebuffer</a> in order to
use this attribute, currently only supported with VNC, Spice and
egl-headless graphics devices.
<p>
Note: There are also some implications on the usage of guest's
address type depending on the <code>model</code> attribute,
see the <code>address</code> element below.
</p>
</dd></dl>
<p>
Note: The <code>managed</code> attribute is only used with
<code>type='pci'</code> and is ignored by all the other device types,
thus setting <code>managed</code> explicitly with other than a PCI
device has the same effect as omitting it. Similarly,
<code>model</code> attribute is only supported by mediated devices and
ignored by all other device types.
</p>
</dd>
<dt>
<code>source</code>
</dt>
<dd>The source element describes the device as seen from the host using
the following mechanism to describe:
<dl><dt><code>usb</code></dt><dd>The USB device can either be addressed by vendor / product id
using the <code>vendor</code> and <code>product</code> elements
or by the device's address on the host using the
<code>address</code> element.
<p><span class="since">Since 1.0.0</span>, the <code>source</code>
element of USB devices may contain <code>startupPolicy</code>
attribute which can be used to define policy what to do if the
specified host USB device is not found. The attribute accepts
the following values:
</p>
<table class="top_table"><tr><td> mandatory </td><td> fail if missing for any reason (the default) </td></tr><tr><td> requisite </td><td> fail if missing on boot up,
drop if missing on migrate/restore/revert </td></tr><tr><td> optional </td><td> drop if missing at any start attempt </td></tr></table>
</dd><dt><code>pci</code></dt><dd>PCI devices can only be described by their <code>address</code>.
</dd><dt><code>scsi</code></dt><dd>SCSI devices are described by both the <code>adapter</code>
and <code>address</code> elements. The <code>address</code>
element includes a <code>bus</code> attribute (a 2-digit bus
number), a <code>target</code> attribute (a 10-digit target
number), and a <code>unit</code> attribute (a 20-digit unit
number on the bus). Not all hypervisors support larger
<code>target</code> and <code>unit</code> values. It is up
to each hypervisor to determine the maximum value supported
for the adapter.
<p><span class="since">Since 1.2.8</span>, the <code>source</code>
element of a SCSI device may contain the <code>protocol</code>
attribute. When the attribute is set to "iscsi", the host
device XML follows the network <a href="#elementsDisks">disk</a>
device using the same <code>name</code> attribute and optionally
using the <code>auth</code> element to provide the authentication
credentials to the iSCSI server.
</p>
</dd><dt><code>scsi_host</code></dt><dd><span class="since">Since 2.5.0</span>, multiple LUNs behind a
single SCSI HBA are described by a <code>protocol</code>
attribute set to "vhost" and a <code>wwpn</code> attribute that
is the vhost_scsi wwpn (16 hexadecimal digits with a prefix of
"naa.") established in the host configfs.
</dd><dt><code>mdev</code></dt><dd>Mediated devices (<span class="since">Since 3.2.0</span>) are
described by the <code>address</code> element. The
<code>address</code> element contains a single mandatory attribute
<code>uuid</code>.
</dd></dl>
</dd>
<dt><code>vendor</code>, <code>product</code></dt>
<dd>The <code>vendor</code> and <code>product</code> elements each have an
<code>id</code> attribute that specifies the USB vendor and product id.
The ids can be given in decimal, hexadecimal (starting with 0x) or
octal (starting with 0) form.</dd>
<dt>
<code>boot</code>
</dt>
<dd>Specifies that the device is bootable. The <code>order</code>
attribute determines the order in which devices will be tried during
boot sequence. The per-device <code>boot</code> elements cannot be
used together with general boot elements in
<a href="#elementsOSBIOS">BIOS bootloader</a> section.
<span class="since">Since 0.8.8</span> for PCI devices,
<span class="since">Since 1.0.1</span> for USB devices.
</dd>
<dt>
<code>rom</code>
</dt>
<dd>The <code>rom</code> element is used to change how a PCI
device's ROM is presented to the guest. The optional <code>bar</code>
attribute can be set to "on" or "off", and determines whether
or not the device's ROM will be visible in the guest's memory
map. (In PCI documentation, the "rombar" setting controls the
presence of the Base Address Register for the ROM). If no rom
bar is specified, the qemu default will be used (older
versions of qemu used a default of "off", while newer qemus
have a default of "on"). <span class="since">Since
0.9.7 (QEMU and KVM only)</span>. The optional
<code>file</code> attribute contains an absolute path to a binary file
to be presented to the guest as the device's ROM BIOS. This
can be useful, for example, to provide a PXE boot ROM for a
virtual function of an sr-iov capable ethernet device (which
has no boot ROMs for the VFs).
<span class="since">Since 0.9.10 (QEMU and KVM only)</span>.
The optional <code>enabled</code> attribute can be set to
<code>no</code> to disable PCI ROM loading completely for the device;
if PCI ROM loading is disabled through this attribute, attempts to
tweak the loading process further using the <code>bar</code> or
<code>file</code> attributes will be rejected.
<span class="since">Since 4.3.0 (QEMU and KVM only)</span>.
</dd>
<dt>
<code>address</code>
</dt>
<dd>The <code>address</code> element for USB devices has a
<code>bus</code> and <code>device</code> attribute to specify the
USB bus and device number the device appears at on the host.
The values of these attributes can be given in decimal, hexadecimal
(starting with 0x) or octal (starting with 0) form.
For PCI devices the element carries 4 attributes allowing to designate
the device as can be found with the <code>lspci</code> or
with <code>virsh nodedev-list</code>. For SCSI devices a 'drive'
address type must be used. For mediated devices, which are software-only
devices defining an allocation of resources on the physical parent device,
the address type used must conform to the <code>model</code> attribute
of element <code>hostdev</code>, e.g. any address type other than PCI for
<code>vfio-pci</code> device API or any address type other than CCW for
<code>vfio-ccw</code> device API will result in an error.
<a href="#elementsAddress">See above</a> for more details on the address
element.</dd>
<dt>
<code>driver</code>
</dt>
<dd>
PCI devices can have an optional <code>driver</code>
subelement that specifies which backend driver to use for PCI
device assignment. Use the <code>name</code> attribute to
select either "vfio" (for the new VFIO device assignment
backend, which is compatible with UEFI SecureBoot) or "kvm"
(the legacy device assignment handled directly by the KVM
kernel module)<span class="since">Since 1.0.5 (QEMU and KVM
only, requires kernel 3.6 or newer)</span>. When specified,
device assignment will fail if the requested method of device
assignment isn't available on the host. When not specified,
the default is "vfio" on systems where the VFIO driver is
available and loaded, and "kvm" on older systems, or those
where the VFIO driver hasn't been
loaded <span class="since">Since 1.1.3</span> (prior to that
the default was always "kvm").
</dd>
<dt>
<code>readonly</code>
</dt>
<dd>Indicates that the device is readonly, only supported by SCSI host
device now. <span class="since">Since 1.0.6 (QEMU and KVM only)</span>
</dd>
<dt>
<code>shareable</code>
</dt>
<dd>If present, this indicates the device is expected to be shared
between domains (assuming the hypervisor and OS support this).
Only supported by SCSI host device.
<span class="since">Since 1.0.6</span>
<p>
Note: Although <code>shareable</code> was introduced
<span class="since">in 1.0.6</span>, it did not work as
as expected until <span class="since">1.2.2</span>.
</p>
</dd>
</dl>
<h5>
<a id="elementsHostDevCaps">Block / character devices</a>
<a class="headerlink" href="#elementsHostDevCaps" title="Permalink to this headline">¶</a>
</h5>
<p>
Block / character devices from the host can be passed through
to the guest using the <code>hostdev</code> element. This is
only possible with container based virtualization. Devices are specified
by a fully qualified path.
<span class="since">since after 1.0.1 for LXC</span>:
</p>
<pre>
...
<hostdev mode='capabilities' type='storage'>
<source>
<block>/dev/sdf1</block>
</source>
</hostdev>
...
</pre>
<pre>
...
<hostdev mode='capabilities' type='misc'>
<source>
<char>/dev/input/event3</char>
</source>
</hostdev>
...
</pre>
<pre>
...
<hostdev mode='capabilities' type='net'>
<source>
<interface>eth0</interface>
</source>
</hostdev>
...
</pre>
<dl>
<dt>
<code>hostdev</code>
</dt>
<dd>The <code>hostdev</code> element is the main container for describing
host devices. For block/character device passthrough <code>mode</code> is
always "capabilities" and <code>type</code> is "storage" for a block
device, "misc" for a character device and "net" for a host network
interface.
</dd>
<dt>
<code>source</code>
</dt>
<dd>The source element describes the device as seen from the host.
For block devices, the path to the block device in the host
OS is provided in the nested "block" element, while for character
devices the "char" element is used. For network interfaces, the
name of the interface is provided in the "interface" element.
</dd>
</dl>
<h4>
<a id="elementsRedir">Redirected devices</a>
<a class="headerlink" href="#elementsRedir" title="Permalink to this headline">¶</a>
</h4>
<p>
USB device redirection through a character device is
supported <span class="since">since after 0.9.5 (KVM
only)</span>:
</p>
<pre>
...
<devices>
<redirdev bus='usb' type='tcp'>
<source mode='connect' host='localhost' service='4000'/>
<boot order='1'/>
</redirdev>
<redirfilter>
<usbdev class='0x08' vendor='0x1234' product='0xbeef' version='2.56' allow='yes'/>
<usbdev allow='no'/>
</redirfilter>
</devices>
...</pre>
<dl>
<dt>
<code>redirdev</code>
</dt>
<dd>The <code>redirdev</code> element is the main container for
describing redirected devices. <code>bus</code> must be "usb"
for a USB device.
An additional attribute <code>type</code> is required,
matching one of the
supported <a href="#elementsConsole">serial device</a> types,
to describe the host side of the
tunnel; <code>type='tcp'</code>
or <code>type='spicevmc'</code> (which uses the usbredir
channel of a <a href="#elementsGraphics">SPICE graphics
device</a>) are typical. The redirdev element has an optional
sub-element <code><address></code> which can tie the
device to a particular controller. Further sub-elements,
such as <code><source></code>, may be required according
to the given type, although a <code><target></code> sub-element
is not required (since the consumer of the character device is
the hypervisor itself, rather than a device visible in the guest).
</dd>
<dt>
<code>boot</code>
</dt>
<dd>Specifies that the device is bootable.
The <code>order</code> attribute determines the order in which
devices will be tried during boot sequence. The per-device
<code>boot</code> elements cannot be used together with general
boot elements in <a href="#elementsOSBIOS">BIOS bootloader</a> section.
(<span class="since">Since 1.0.1</span>)
</dd>
<dt>
<code>redirfilter</code>
</dt>
<dd>The<code> redirfilter </code>element is used for creating the
filter rule to filter out certain devices from redirection.
It uses sub-element <code><usbdev></code> to define each filter rule.
<code>class</code> attribute is the USB Class code, for example,
0x08 represents mass storage devices. The USB device can be addressed by
vendor / product id using the <code>vendor</code> and <code>product</code> attributes.
<code>version</code> is the device revision from the bcdDevice field (not
the version of the USB protocol).
These four attributes are optional and <code>-1</code> can be used to allow
any value for them. <code>allow</code> attribute is mandatory,
'yes' means allow, 'no' for deny.
</dd>
</dl>
<h4>
<a id="elementsSmartcard">Smartcard devices</a>
<a class="headerlink" href="#elementsSmartcard" title="Permalink to this headline">¶</a>
</h4>
<p>
A virtual smartcard device can be supplied to the guest via the
<code>smartcard</code> element. A USB smartcard reader device on
the host cannot be used on a guest with simple device
passthrough, since it will then not be available on the host,
possibly locking the host computer when it is "removed".
Therefore, some hypervisors provide a specialized virtual device
that can present a smartcard interface to the guest, with
several modes for describing how credentials are obtained from
the host or even a from a channel created to a third-party
smartcard provider. <span class="since">Since 0.8.8</span>
</p>
<pre>
...
<devices>
<smartcard mode='host'/>
<smartcard mode='host-certificates'>
<certificate>cert1</certificate>
<certificate>cert2</certificate>
<certificate>cert3</certificate>
<database>/etc/pki/nssdb/</database>
</smartcard>
<smartcard mode='passthrough' type='tcp'>
<source mode='bind' host='127.0.0.1' service='2001'/>
<protocol type='raw'/>
<address type='ccid' controller='0' slot='0'/>
</smartcard>
<smartcard mode='passthrough' type='spicevmc'/>
</devices>
...
</pre>
<p>
The <code><smartcard></code> element has a mandatory
attribute <code>mode</code>. The following modes are supported;
in each mode, the guest sees a device on its USB bus that
behaves like a physical USB CCID (Chip/Smart Card Interface
Device) card.
</p>
<dl>
<dt>
<code>host</code>
</dt>
<dd>The simplest operation, where the hypervisor relays all
requests from the guest into direct access to the host's
smartcard via NSS. No other attributes or sub-elements are
required. See below about the use of an
optional <code><address></code> sub-element.</dd>
<dt>
<code>host-certificates</code>
</dt>
<dd>Rather than requiring a smartcard to be plugged into the
host, it is possible to provide three NSS certificate names
residing in a database on the host. These certificates can be
generated via the command <code>certutil -d /etc/pki/nssdb -x -t
CT,CT,CT -S -s CN=cert1 -n cert1</code>, and the resulting three
certificate names must be supplied as the content of each of
three <code><certificate></code> sub-elements. An
additional sub-element <code><database></code> can specify
the absolute path to an alternate directory (matching
the <code>-d</code> option of the <code>certutil</code> command
when creating the certificates); if not present, it defaults to
/etc/pki/nssdb.</dd>
<dt>
<code>passthrough</code>
</dt>
<dd>Rather than having the hypervisor directly communicate with
the host, it is possible to tunnel all requests through a
secondary character device to a third-party provider (which may
in turn be talking to a smartcard or using three certificate
files). In this mode of operation, an additional
attribute <code>type</code> is required, matching one of the
supported <a href="#elementsConsole">serial device</a> types, to
describe the host side of the tunnel; <code>type='tcp'</code>
or <code>type='spicevmc'</code> (which uses the smartcard
channel of a <a href="#elementsGraphics">SPICE graphics
device</a>) are typical. Further sub-elements, such
as <code><source></code>, may be required according to the
given type, although a <code><target></code> sub-element
is not required (since the consumer of the character device is
the hypervisor itself, rather than a device visible in the
guest).</dd>
</dl>
<p>
Each mode supports an optional
sub-element <code><address></code>, which fine-tunes the
correlation between the smartcard and a ccid bus
controller, <a href="#elementsAddress">documented above</a>.
For now, qemu only supports at most one
smartcard, with an address of bus=0 slot=0.
</p>
<h4>
<a id="elementsNICS">Network interfaces</a>
<a class="headerlink" href="#elementsNICS" title="Permalink to this headline">¶</a>
</h4>
<pre>
...
<devices>
<interface type='direct' trustGuestRxFilters='yes'>
<source dev='eth0'/>
<mac address='52:54:00:5d:c7:9e'/>
<boot order='1'/>
<rom bar='off'/>
</interface>
</devices>
...</pre>
<p>
There are several possibilities for specifying a network
interface visible to the guest. Each subsection below provides
more details about common setup options.
</p>
<p><span class="since">Since 1.2.10</span>),
the <code>interface</code> element
property <code>trustGuestRxFilters</code> provides the
capability for the host to detect and trust reports from the
guest regarding changes to the interface mac address and receive
filters by setting the attribute to <code>yes</code>. The default
setting for the attribute is <code>no</code> for security
reasons and support depends on the guest network device model as
well as the type of connection on the host - currently it is
only supported for the virtio device model and for macvtap
connections on the host.
</p>
<p>
Each <code><interface></code> element has an
optional <code><address></code> sub-element that can tie
the interface to a particular pci slot, with
attribute <code>type='pci'</code>
as <a href="#elementsAddress">documented above</a>.
</p>
<h5>
<a id="elementsNICSVirtual">Virtual network</a>
<a class="headerlink" href="#elementsNICSVirtual" title="Permalink to this headline">¶</a>
</h5>
<p>
<strong>
<em>
This is the recommended config for general guest connectivity on
hosts with dynamic / wireless networking configs (or multi-host
environments where the host hardware details are described
separately in a <code><network></code>
definition <span class="since">Since 0.9.4</span>).
</em>
</strong>
</p>
<p>
Provides a connection whose details are described by the named
network definition. Depending on the virtual network's "forward
mode" configuration, the network may be totally isolated
(no <code><forward></code> element given), NAT'ing to an
explicit network device or to the default route
(<code><forward mode='nat'></code>), routed with no NAT
(<code><forward mode='route'/></code>), or connected
directly to one of the host's network interfaces (via macvtap)
or bridge devices ((<code><forward
mode='bridge|private|vepa|passthrough'/></code> <span class="since">Since
0.9.4</span>)
</p>
<p>
For networks with a forward mode of bridge, private, vepa, and
passthrough, it is assumed that the host has any necessary DNS
and DHCP services already setup outside the scope of libvirt. In
the case of isolated, nat, and routed networks, DHCP and DNS are
provided on the virtual network by libvirt, and the IP range can
be determined by examining the virtual network config with
'<code>virsh net-dumpxml [networkname]</code>'. There is one
virtual network called 'default' setup out of the box which does
NAT'ing to the default route and has an IP range
of <code>192.168.122.0/255.255.255.0</code>. Each guest will
have an associated tun device created with a name of vnetN,
which can also be overridden with the <target> element
(see
<a href="#elementsNICSTargetOverride">overriding the target element</a>).
</p>
<p>
When the source of an interface is a network,
a <code>portgroup</code> can be specified along with the name of
the network; one network may have multiple portgroups defined,
with each portgroup containing slightly different configuration
information for different classes of network
connections. <span class="since">Since 0.9.4</span>.
</p>
<p>
Also, similar to <code>direct</code> network connections
(described below), a connection of type <code>network</code> may
specify a <code>virtualport</code> element, with configuration
data to be forwarded to a vepa (802.1Qbg) or 802.1Qbh compliant
switch (<span class="since">Since 0.8.2</span>), or to an
Open vSwitch virtual switch (<span class="since">Since
0.9.11</span>).
</p>
<p>
Since the actual type of switch may vary depending on the
configuration in the <code><network></code> on the host,
it is acceptable to omit the virtualport <code>type</code>
attribute, and specify attributes from multiple different
virtualport types (and also to leave out certain attributes); at
domain startup time, a complete <code><virtualport></code>
element will be constructed by merging together the type and
attributes defined in the network and the portgroup referenced
by the interface. The newly-constructed virtualport is a combination
of them. The attributes from lower virtualport can't make change
on the ones defined in higher virtualport.
Interface takes the highest priority, portgroup is lowest priority.
(<span class="since">Since 0.10.0</span>). For example, in order
to work properly with both an 802.1Qbh switch and an Open vSwitch
switch, you may choose to specify no type, but both
a <code>profileid</code> (in case the switch is 802.1Qbh) and
an <code>interfaceid</code> (in case the switch is Open vSwitch)
(you may also omit the other attributes, such as managerid,
typeid, or profileid, to be filled in from the
network's <code><virtualport></code>). If you want to
limit a guest to connecting only to certain types of switches,
you can specify the virtualport type, but still omit some/all of
the parameters - in this case if the host's network has a
different type of virtualport, connection of the interface will
fail.
</p>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
</interface>
...
<interface type='network'>
<source network='default' portgroup='engineering'/>
<target dev='vnet7'/>
<mac address="00:11:22:33:44:55"/>
<virtualport>
<parameters instanceid='09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f'/>
</virtualport>
</interface>
</devices>
...</pre>
<h5>
<a id="elementsNICSBridge">Bridge to LAN</a>
<a class="headerlink" href="#elementsNICSBridge" title="Permalink to this headline">¶</a>
</h5>
<p>
<strong>
<em>
This is the recommended config for general guest connectivity on
hosts with static wired networking configs.
</em>
</strong>
</p>
<p>
Provides a bridge from the VM directly to the LAN. This assumes
there is a bridge device on the host which has one or more of the hosts
physical NICs enslaved. The guest VM will have an associated tun device
created with a name of vnetN, which can also be overridden with the
<target> element (see
<a href="#elementsNICSTargetOverride">overriding the target element</a>).
The tun device will be enslaved to the bridge. The IP range / network
configuration is whatever is used on the LAN. This provides the guest VM
full incoming & outgoing net access just like a physical machine.
</p>
<p>
On Linux systems, the bridge device is normally a standard Linux
host bridge. On hosts that support Open vSwitch, it is also
possible to connect to an Open vSwitch bridge device by adding
a <code><virtualport type='openvswitch'/></code> to the
interface definition. (<span class="since">Since
0.9.11</span>). The Open vSwitch type virtualport accepts two
parameters in its <code><parameters></code> element -
an <code>interfaceid</code> which is a standard uuid used to
uniquely identify this particular interface to Open vSwitch (if
you do not specify one, a random interfaceid will be generated
for you when you first define the interface), and an
optional <code>profileid</code> which is sent to Open vSwitch as
the interfaces "port-profile".
</p>
<pre>
...
<devices>
...
<interface type='bridge'>
<source bridge='br0'/>
</interface>
<interface type='bridge'>
<source bridge='br1'/>
<target dev='vnet7'/>
<mac address="00:11:22:33:44:55"/>
</interface>
<interface type='bridge'>
<source bridge='ovsbr'/>
<virtualport type='openvswitch'>
<parameters profileid='menial' interfaceid='09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f'/>
</virtualport>
</interface>
...
</devices>
...</pre>
<p>
On hosts that support Open vSwitch on the kernel side and have the
Midonet Host Agent configured, it is also possible to connect to the
'midonet' bridge device by adding a
<code><virtualport type='midonet'/></code> to the
interface definition. (<span class="since">Since
1.2.13</span>). The Midonet virtualport type requires an
<code>interfaceid</code> attribute in its
<code><parameters></code> element. This interface id is the UUID
that specifies which port in the virtual network topology will be bound
to the interface.
</p>
<pre>
...
<devices>
...
<interface type='bridge'>
<source bridge='br0'/>
</interface>
<interface type='bridge'>
<source bridge='br1'/>
<target dev='vnet7'/>
<mac address="00:11:22:33:44:55"/>
</interface>
<interface type='bridge'>
<source bridge='midonet'/>
<virtualport type='midonet'>
<parameters interfaceid='0b2d64da-3d0e-431e-afdd-804415d6ebbb'/>
</virtualport>
</interface>
...
</devices>
...</pre>
<h5>
<a id="elementsNICSSlirp">Userspace SLIRP stack</a>
<a class="headerlink" href="#elementsNICSSlirp" title="Permalink to this headline">¶</a>
</h5>
<p>
Provides a virtual LAN with NAT to the outside world. The virtual
network has DHCP & DNS services and will give the guest VM addresses
starting from <code>10.0.2.15</code>. The default router will be
<code>10.0.2.2</code> and the DNS server will be <code>10.0.2.3</code>.
This networking is the only option for unprivileged users who need their
VMs to have outgoing access. <span class="since">Since 3.8.0</span>
it is possible to override the default network address by
including an <code>ip</code> element specifying an IPv4
address in its one mandatory attribute, <code>address</code>.
Optionally, a second <code>ip</code> element with a
<code>family</code> attribute set to "ipv6" can be
specified to add an IPv6 address to the interface.
<code>address</code>. Optionally, address
<code>prefix</code> can be specified.
</p>
<pre>
...
<devices>
<interface type='user'/>
...
<interface type='user'>
<mac address="00:11:22:33:44:55"/>
<ip family='ipv4' address='172.17.2.0' prefix='24'/>
<ip family='ipv6' address='2001:db8:ac10:fd01::' prefix='64'/>
</interface>
</devices>
...</pre>
<h5>
<a id="elementsNICSEthernet">Generic ethernet connection</a>
<a class="headerlink" href="#elementsNICSEthernet" title="Permalink to this headline">¶</a>
</h5>
<p>
Provides a means for the administrator to execute an arbitrary script
to connect the guest's network to the LAN. The guest will have a tun
device created with a name of vnetN, which can also be overridden with the
<target> element. After creating the tun device a shell script will
be run which is expected to do whatever host network integration is
required. By default this script is called /etc/qemu-ifup but can be
overridden.
</p>
<pre>
...
<devices>
<interface type='ethernet'/>
...
<interface type='ethernet'>
<target dev='vnet7'/>
<script path='/etc/qemu-ifup-mynet'/>
</interface>
</devices>
...</pre>
<h5>
<a id="elementsNICSDirect">Direct attachment to physical interface</a>
<a class="headerlink" href="#elementsNICSDirect" title="Permalink to this headline">¶</a>
</h5>
<p>
Provides direct attachment of the virtual machine's NIC to the given
physical interface of the host.
<span class="since">Since 0.7.7 (QEMU and KVM only)</span><br/>
This setup requires the Linux macvtap
driver to be available. <span class="since">(Since Linux 2.6.34.)</span>
One of the modes 'vepa'
( <a href="http://www.ieee802.org/1/files/public/docs2009/new-evb-congdon-vepa-modular-0709-v01.pdf">
'Virtual Ethernet Port Aggregator'</a>), 'bridge' or 'private'
can be chosen for the operation mode of the macvtap device, 'vepa'
being the default mode. The individual modes cause the delivery of
packets to behave as follows:
</p>
<p>
If the model type is set to <code>virtio</code> and
interface's <code>trustGuestRxFilters</code> attribute is set
to <code>yes</code>, changes made to the interface mac address,
unicast/multicast receive filters, and vlan settings in the
guest will be monitored and propagated to the associated macvtap
device on the host (<span class="since">Since
1.2.10</span>). If <code>trustGuestRxFilters</code> is not set,
or is not supported for the device model in use, an attempted
change to the mac address originating from the guest side will
result in a non-working network connection.
</p>
<dl>
<dt>
<code>vepa</code>
</dt>
<dd>All VMs' packets are sent to the external bridge. Packets
whose destination is a VM on the same host as where the
packet originates from are sent back to the host by the VEPA
capable bridge (today's bridges are typically not VEPA capable).</dd>
<dt>
<code>bridge</code>
</dt>
<dd>Packets whose destination is on the same host as where they
originate from are directly delivered to the target macvtap device.
Both origin and destination devices need to be in bridge mode
for direct delivery. If either one of them is in <code>vepa</code> mode,
a VEPA capable bridge is required.</dd>
<dt>
<code>private</code>
</dt>
<dd>All packets are sent to the external bridge and will only be
delivered to a target VM on the same host if they are sent through an
external router or gateway and that device sends them back to the
host. This procedure is followed if either the source or destination
device is in <code>private</code> mode.</dd>
<dt>
<code>passthrough</code>
</dt>
<dd>This feature attaches a virtual function of a SRIOV capable
NIC directly to a VM without losing the migration capability.
All packets are sent to the VF/IF of the configured network device.
Depending on the capabilities of the device additional prerequisites or
limitations may apply; for example, on Linux this requires
kernel 2.6.38 or newer. <span class="since">Since 0.9.2</span></dd>
</dl>
<pre>
...
<devices>
...
<interface type='direct' trustGuestRxFilters='no'>
<source dev='eth0' mode='vepa'/>
</interface>
</devices>
...</pre>
<p>
The network access of direct attached virtual machines can be
managed by the hardware switch to which the physical interface
of the host machine is connected to.
</p>
<p>
The interface can have additional parameters as shown below,
if the switch is conforming to the IEEE 802.1Qbg standard.
The parameters of the virtualport element are documented in more detail
in the IEEE 802.1Qbg standard. The values are network specific and
should be provided by the network administrator. In 802.1Qbg terms,
the Virtual Station Interface (VSI) represents the virtual interface
of a virtual machine. <span class="since">Since 0.8.2</span>
</p>
<p>
Please note that IEEE 802.1Qbg requires a non-zero value for the
VLAN ID.
</p>
<dl>
<dt>
<code>managerid</code>
</dt>
<dd>The VSI Manager ID identifies the database containing the VSI type
and instance definitions. This is an integer value and the
value 0 is reserved.</dd>
<dt>
<code>typeid</code>
</dt>
<dd>The VSI Type ID identifies a VSI type characterizing the network
access. VSI types are typically managed by network administrator.
This is an integer value.
</dd>
<dt>
<code>typeidversion</code>
</dt>
<dd>The VSI Type Version allows multiple versions of a VSI Type.
This is an integer value.
</dd>
<dt>
<code>instanceid</code>
</dt>
<dd>The VSI Instance ID Identifier is generated when a VSI instance
(i.e. a virtual interface of a virtual machine) is created.
This is a globally unique identifier.
</dd>
</dl>
<pre>
...
<devices>
...
<interface type='direct'>
<source dev='eth0.2' mode='vepa'/>
<virtualport type="802.1Qbg">
<parameters managerid="11" typeid="1193047" typeidversion="2" instanceid="09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f"/>
</virtualport>
</interface>
</devices>
...</pre>
<p>
The interface can have additional parameters as shown below
if the switch is conforming to the IEEE 802.1Qbh standard.
The values are network specific and should be provided by the
network administrator. <span class="since">Since 0.8.2</span>
</p>
<dl>
<dt>
<code>profileid</code>
</dt>
<dd>The profile ID contains the name of the port profile that is to
be applied to this interface. This name is resolved by the port
profile database into the network parameters from the port profile,
and those network parameters will be applied to this interface.
</dd>
</dl>
<pre>
...
<devices>
...
<interface type='direct'>
<source dev='eth0' mode='private'/>
<virtualport type='802.1Qbh'>
<parameters profileid='finance'/>
</virtualport>
</interface>
</devices>
...
</pre>
<h5>
<a id="elementsNICSHostdev">PCI Passthrough</a>
<a class="headerlink" href="#elementsNICSHostdev" title="Permalink to this headline">¶</a>
</h5>
<p>
A PCI network device (specified by the <source> element)
is directly assigned to the guest using generic device
passthrough, after first optionally setting the device's MAC
address to the configured value, and associating the device with
an 802.1Qbh capable switch using an optionally specified
<virtualport> element (see the examples of virtualport
given above for type='direct' network devices). Note that - due
to limitations in standard single-port PCI ethernet card driver
design - only SR-IOV (Single Root I/O Virtualization) virtual
function (VF) devices can be assigned in this manner; to assign
a standard single-port PCI or PCIe ethernet card to a guest, use
the traditional <hostdev> device definition and
<span class="since">Since 0.9.11</span>
</p>
<p>
To use VFIO device assignment rather than traditional/legacy KVM
device assignment (VFIO is a new method of device assignment
that is compatible with UEFI Secure Boot), a type='hostdev'
interface can have an optional <code>driver</code> sub-element
with a <code>name</code> attribute set to "vfio". To use legacy
KVM device assignment you can set <code>name</code> to "kvm" (or
simply omit the <code><driver></code> element, since "kvm"
is currently the default).
<span class="since">Since 1.0.5 (QEMU and KVM only, requires kernel 3.6 or newer)</span>
</p>
<p>
Note that this "intelligent passthrough" of network devices is
very similar to the functionality of a standard <hostdev>
device, the difference being that this method allows specifying
a MAC address and <virtualport> for the passed-through
device. If these capabilities are not required, if you have a
standard single-port PCI, PCIe, or USB network card that doesn't
support SR-IOV (and hence would anyway lose the configured MAC
address during reset after being assigned to the guest domain),
or if you are using a version of libvirt older than 0.9.11, you
should use standard <hostdev> to assign the device to the
guest instead of <interface type='hostdev'/>.
</p>
<p>
Similar to the functionality of a standard <hostdev> device,
when <code>managed</code> is "yes", it is detached from the host
before being passed on to the guest, and reattached to the host
after the guest exits. If <code>managed</code> is omitted or "no",
the user is responsible to call <code>virNodeDeviceDettach</code>
(or <code>virsh nodedev-detach</code>) before starting the guest
or hot-plugging the device, and <code>virNodeDeviceReAttach</code>
(or <code>virsh nodedev-reattach</code>) after hot-unplug or
stopping the guest.
</p>
<pre>
...
<devices>
<interface type='hostdev' managed='yes'>
<driver name='vfio'/>
<source>
<address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/>
</source>
<mac address='52:54:00:6d:90:02'/>
<virtualport type='802.1Qbh'>
<parameters profileid='finance'/>
</virtualport>
</interface>
</devices>
...</pre>
<h5>
<a id="elementsNICSMulticast">Multicast tunnel</a>
<a class="headerlink" href="#elementsNICSMulticast" title="Permalink to this headline">¶</a>
</h5>
<p>
A multicast group is setup to represent a virtual network. Any VMs
whose network devices are in the same multicast group can talk to each
other even across hosts. This mode is also available to unprivileged
users. There is no default DNS or DHCP support and no outgoing network
access. To provide outgoing network access, one of the VMs should have a
2nd NIC which is connected to one of the first 4 network types and do the
appropriate routing. The multicast protocol is compatible with that used
by user mode linux guests too. The source address used must be from the
multicast address block.
</p>
<pre>
...
<devices>
<interface type='mcast'>
<mac address='52:54:00:6d:90:01'/>
<source address='230.0.0.1' port='5558'/>
</interface>
</devices>
...</pre>
<h5>
<a id="elementsNICSTCP">TCP tunnel</a>
<a class="headerlink" href="#elementsNICSTCP" title="Permalink to this headline">¶</a>
</h5>
<p>
A TCP client/server architecture provides a virtual network. One VM
provides the server end of the network, all other VMS are configured as
clients. All network traffic is routed between the VMs via the server.
This mode is also available to unprivileged users. There is no default
DNS or DHCP support and no outgoing network access. To provide outgoing
network access, one of the VMs should have a 2nd NIC which is connected
to one of the first 4 network types and do the appropriate routing.</p>
<pre>
...
<devices>
<interface type='server'>
<mac address='52:54:00:22:c9:42'/>
<source address='192.168.0.1' port='5558'/>
</interface>
...
<interface type='client'>
<mac address='52:54:00:8b:c9:51'/>
<source address='192.168.0.1' port='5558'/>
</interface>
</devices>
...</pre>
<h5>
<a id="elementsNICSUDP">UDP unicast tunnel</a>
<a class="headerlink" href="#elementsNICSUDP" title="Permalink to this headline">¶</a>
</h5>
<p>
A UDP unicast architecture provides a virtual network which enables
connections between QEMU instances using QEMU's UDP infrastructure.
The xml "source" address is the endpoint address to which the UDP socket
packets will be sent from the host running QEMU.
The xml "local" address is the address of the interface from which the
UDP socket packets will originate from the QEMU host.
<span class="since">Since 1.2.20</span></p>
<pre>
...
<devices>
<interface type='udp'>
<mac address='52:54:00:22:c9:42'/>
<source address='127.0.0.1' port='11115'>
<local address='127.0.0.1' port='11116'/>
</source>
</interface>
</devices>
...</pre>
<h5>
<a id="elementsNICSModel">Setting the NIC model</a>
<a class="headerlink" href="#elementsNICSModel" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet1'/>
<b><model type='ne2k_pci'/></b>
</interface>
</devices>
...</pre>
<p>
For hypervisors which support this, you can set the model of
emulated network interface card.
</p>
<p>
The values for <code>type</code> aren't defined specifically by
libvirt, but by what the underlying hypervisor supports (if
any). For QEMU and KVM you can get a list of supported models
with these commands:
</p>
<pre>
qemu -net nic,model=? /dev/null
qemu-kvm -net nic,model=? /dev/null
</pre>
<p>
Typical values for QEMU and KVM include:
ne2k_isa i82551 i82557b i82559er ne2k_pci pcnet rtl8139 e1000 virtio
</p>
<h5>
<a id="elementsDriverBackendOptions">Setting NIC driver-specific options</a>
<a class="headerlink" href="#elementsDriverBackendOptions" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet1'/>
<model type='virtio'/>
<b><driver name='vhost' txmode='iothread' ioeventfd='on' event_idx='off' queues='5' rx_queue_size='256' tx_queue_size='256'>
<host csum='off' gso='off' tso4='off' tso6='off' ecn='off' ufo='off' mrg_rxbuf='off'/>
<guest csum='off' tso4='off' tso6='off' ecn='off' ufo='off'/>
</driver>
</b></interface>
</devices>
...</pre>
<p>
Some NICs may have tunable driver-specific options. These are
set as attributes of the <code>driver</code> sub-element of the
interface definition. Currently the following attributes are
available for the <code>"virtio"</code> NIC driver:
</p>
<dl>
<dt>
<code>name</code>
</dt>
<dd>
The optional <code>name</code> attribute forces which type of
backend driver to use. The value can be either 'qemu' (a
user-space backend) or 'vhost' (a kernel backend, which
requires the vhost module to be provided by the kernel); an
attempt to require the vhost driver without kernel support
will be rejected. If this attribute is not present, then the
domain defaults to 'vhost' if present, but silently falls back
to 'qemu' without error.
<span class="since">Since 0.8.8 (QEMU and KVM only)</span>
</dd>
<dd>
For interfaces of type='hostdev' (PCI passthrough devices)
the <code>name</code> attribute can optionally be set to
"vfio" or "kvm". "vfio" tells libvirt to use VFIO device
assignment rather than traditional KVM device assignment (VFIO
is a new method of device assignment that is compatible with
UEFI Secure Boot), and "kvm" tells libvirt to use the legacy
device assignment performed directly by the kvm kernel module
(the default is currently "kvm", but is subject to change).
<span class="since">Since 1.0.5 (QEMU and KVM only, requires
kernel 3.6 or newer)</span>
</dd>
<dd>
For interfaces of type='vhostuser', the <code>name</code>
attribute is ignored. The backend driver used is always
vhost-user.
</dd>
<dt>
<code>txmode</code>
</dt>
<dd>
The <code>txmode</code> attribute specifies how to handle
transmission of packets when the transmit buffer is full. The
value can be either 'iothread' or 'timer'.
<span class="since">Since 0.8.8 (QEMU and KVM only)</span><br/><br/>
If set to 'iothread', packet tx is all done in an iothread in
the bottom half of the driver (this option translates into
adding "tx=bh" to the qemu commandline -device virtio-net-pci
option).<br/><br/>
If set to 'timer', tx work is done in qemu, and if there is
more tx data than can be sent at the present time, a timer is
set before qemu moves on to do other things; when the timer
fires, another attempt is made to send more data.<br/><br/>
The resulting difference, according to the qemu developer who
added the option is: "bh makes tx more asynchronous and reduces
latency, but potentially causes more processor bandwidth
contention since the CPU doing the tx isn't necessarily the
CPU where the guest generated the packets."<br/><br/>
<b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</dd>
<dt>
<code>ioeventfd</code>
</dt>
<dd>
This optional attribute allows users to set
<a href="https://patchwork.kernel.org/patch/43390/">
domain I/O asynchronous handling</a> for interface device.
The default is left to the discretion of the hypervisor.
Accepted values are "on" and "off". Enabling this allows
qemu to execute VM while a separate thread handles I/O.
Typically guests experiencing high system CPU utilization
during I/O will benefit from this. On the other hand,
on overloaded host it could increase guest I/O latency.
<span class="since">Since 0.9.3 (QEMU and KVM only)</span><br/><br/>
<b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</dd>
<dt>
<code>event_idx</code>
</dt>
<dd>
The <code>event_idx</code> attribute controls some aspects of
device event processing. The value can be either 'on' or 'off'
- if it is on, it will reduce the number of interrupts and
exits for the guest. The default is determined by QEMU;
usually if the feature is supported, default is on. In case
there is a situation where this behavior is suboptimal, this
attribute provides a way to force the feature off.
<span class="since">Since 0.9.5 (QEMU and KVM only)</span><br/><br/>
<b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</dd>
<dt>
<code>queues</code>
</dt>
<dd>
The optional <code>queues</code> attribute controls the number
of queues to be used for either
<a href="https://www.linux-kvm.org/page/Multiqueue"> Multiqueue
virtio-net</a> or <a href="#elementVhostuser">vhost-user</a> network
interfaces. Use of multiple packet processing queues requires the
interface having the <code><model type='virtio'/></code>
element. Each queue will potentially be handled by a different
processor, resulting in much higher throughput.
<span class="since">virtio-net since 1.0.6 (QEMU and KVM only)</span>
<span class="since">vhost-user since 1.2.17 (QEMU and KVM only)</span>
</dd>
<dt>
<code>rx_queue_size</code>
</dt>
<dd>
The optional <code>rx_queue_size</code> attribute controls
the size of virtio ring for each queue as described above.
The default value is hypervisor dependent and may change
across its releases. Moreover, some hypervisors may pose
some restrictions on actual value. For instance, latest
QEMU (as of 2016-09-01) requires value to be a power of two
from [256, 1024] range.
<span class="since">Since 2.3.0 (QEMU and KVM only)</span><br/><br/>
<b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</dd>
<dt>
<code>tx_queue_size</code>
</dt>
<dd>
The optional <code>tx_queue_size</code> attribute controls
the size of virtio ring for each queue as described above.
The default value is hypervisor dependent and may change
across its releases. Moreover, some hypervisors may pose
some restrictions on actual value. For instance, QEMU
v2.9 requires value to be a power of two from [256, 1024]
range. In addition to that, this may work only for a subset of
interface types, e.g. aforementioned QEMU enables this option
only for <code>vhostuser</code> type.
<span class="since">Since 3.7.0 (QEMU and KVM only)</span><br/><br/>
<b>In general you should leave this option alone, unless you
are very certain you know what you are doing.</b>
</dd>
<dt>virtio options</dt>
<dd>
For virtio interfaces,
<a href="#elementsVirtio">Virtio-specific options</a> can also be
set. (<span class="since">Since 3.5.0</span>)
</dd>
</dl>
<p>
Offloading options for the host and guest can be configured using
the following sub-elements:
</p>
<dl>
<dt>
<code>host</code>
</dt>
<dd>
The <code>csum</code>, <code>gso</code>, <code>tso4</code>,
<code>tso6</code>, <code>ecn</code> and <code>ufo</code>
attributes with possible values <code>on</code>
and <code>off</code> can be used to turn off host offloading options.
By default, the supported offloads are enabled by QEMU.
<span class="since">Since 1.2.9 (QEMU only)</span>
The <code>mrg_rxbuf</code> attribute can be used to control
mergeable rx buffers on the host side. Possible values are
<code>on</code> (default) and <code>off</code>.
<span class="since">Since 1.2.13 (QEMU only)</span>
</dd>
<dt>
<code>guest</code>
</dt>
<dd>
The <code>csum</code>, <code>tso4</code>,
<code>tso6</code>, <code>ecn</code> and <code>ufo</code>
attributes with possible values <code>on</code>
and <code>off</code> can be used to turn off guest offloading options.
By default, the supported offloads are enabled by QEMU.
<span class="since">Since 1.2.9 (QEMU only)</span>
</dd>
</dl>
<h5>
<a id="elementsBackendOptions">Setting network backend-specific options</a>
<a class="headerlink" href="#elementsBackendOptions" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet1'/>
<model type='virtio'/>
<b><backend tap='/dev/net/tun' vhost='/dev/vhost-net'/></b>
<driver name='vhost' txmode='iothread' ioeventfd='on' event_idx='off' queues='5'/>
<b><tune>
<sndbuf>1600</sndbuf>
</tune></b>
</interface>
</devices>
...</pre>
<p>
For tuning the backend of the network, the <code>backend</code> element
can be used. The <code>vhost</code> attribute can override the default vhost
device path (<code>/dev/vhost-net</code>) for devices with <code>virtio</code> model.
The <code>tap</code> attribute overrides the tun/tap device path (default:
<code>/dev/net/tun</code>) for network and bridge interfaces. This does not work
in session mode. <span class="since">Since 1.2.9</span>
</p>
<p>
For tap devices there is also <code>sndbuf</code> element which can
adjust the size of send buffer in the host. <span class="since">Since
0.8.8</span>
</p>
<h5>
<a id="elementsNICSTargetOverride">Overriding the target element</a>
<a class="headerlink" href="#elementsNICSTargetOverride" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<b><target dev='vnet1'/></b>
</interface>
</devices>
...</pre>
<p>
If no target is specified, certain hypervisors will
automatically generate a name for the created tun device. This
name can be manually specified, however the name <i>should not
start with either 'vnet', 'vif', 'macvtap', or 'macvlan'</i>,
which are prefixes reserved by libvirt and certain hypervisors.
Manually specified targets using these prefixes may be ignored.
</p>
<p>
Note that for LXC containers, this defines the name of the interface
on the host side. <span class="since">Since 1.2.7</span>, to define
the name of the device on the guest side, the <code>guest</code>
element should be used, as in the following snippet:
</p>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<b><guest dev='myeth'/></b>
</interface>
</devices>
...</pre>
<h5>
<a id="elementsNICSBoot">Specifying boot order</a>
<a class="headerlink" href="#elementsNICSBoot" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet1'/>
<b><boot order='1'/></b>
</interface>
</devices>
...</pre>
<p>
For hypervisors which support this, you can set a specific NIC to
be used for network boot. The <code>order</code> attribute determines
the order in which devices will be tried during boot sequence. The
per-device <code>boot</code> elements cannot be used together with
general boot elements in
<a href="#elementsOSBIOS">BIOS bootloader</a> section.
<span class="since">Since 0.8.8</span>
</p>
<h5>
<a id="elementsNICSROM">Interface ROM BIOS configuration</a>
<a class="headerlink" href="#elementsNICSROM" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet1'/>
<b><rom bar='on' file='/etc/fake/boot.bin'/></b>
</interface>
</devices>
...</pre>
<p>
For hypervisors which support this, you can change how a PCI Network
device's ROM is presented to the guest. The <code>bar</code>
attribute can be set to "on" or "off", and determines whether
or not the device's ROM will be visible in the guest's memory
map. (In PCI documentation, the "rombar" setting controls the
presence of the Base Address Register for the ROM). If no rom
bar is specified, the qemu default will be used (older
versions of qemu used a default of "off", while newer qemus
have a default of "on").
The optional <code>file</code> attribute is used to point to a
binary file to be presented to the guest as the device's ROM
BIOS. This can be useful to provide an alternative boot ROM for a
network device.
<span class="since">Since 0.9.10 (QEMU and KVM only)</span>.
</p>
<h5>
<a id="elementDomain">Setting up a network backend in a driver domain</a>
<a class="headerlink" href="#elementDomain" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
...
<interface type='bridge'>
<source bridge='br0'/>
<b><backenddomain name='netvm'/></b>
</interface>
...
</devices>
...</pre>
<p>
The optional <code>backenddomain</code> element allows specifying a
backend domain (aka driver domain) for the interface. Use the
<code>name</code> attribute to specify the backend domain name. You
can use it to create a direct network link between domains (so data
will not go through host system). Use with type 'ethernet' to create
plain network link, or with type 'bridge' to connect to a bridge inside
the backend domain.
<span class="since">Since 1.2.13 (Xen only)</span>
</p>
<h5>
<a id="elementQoS">Quality of service</a>
<a class="headerlink" href="#elementQoS" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet0'/>
<b><bandwidth>
<inbound average='1000' peak='5000' floor='200' burst='1024'/>
<outbound average='128' peak='256' burst='256'/>
</bandwidth></b>
</interface>
</devices>
...</pre>
<p>
This part of interface XML provides setting quality of service. Incoming
and outgoing traffic can be shaped independently.
The <code>bandwidth</code> element and its child elements are described
in the <a href="formatnetwork.html#elementQoS">QoS</a> section of
the Network XML.
</p>
<h5>
<a id="elementVlanTag">Setting VLAN tag (on supported network types only)</a>
<a class="headerlink" href="#elementVlanTag" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='bridge'>
<b><vlan></b>
<b><tag id='42'/></b>
<b></vlan></b>
<source bridge='ovsbr0'/>
<virtualport type='openvswitch'>
<parameters interfaceid='09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f'/>
</virtualport>
</interface>
<interface type='bridge'>
<b><vlan trunk='yes'></b>
<b><tag id='42'/></b>
<b><tag id='123' nativeMode='untagged'/></b>
<b></vlan></b>
...
</interface>
</devices>
...</pre>
<p>
If (and only if) the network connection used by the guest
supports VLAN tagging transparent to the guest, an
optional <code><vlan></code> element can specify one or
more VLAN tags to apply to the guest's network
traffic <span class="since">Since 0.10.0</span>. Network
connections that support guest-transparent VLAN tagging include
1) type='bridge' interfaces connected to an Open vSwitch bridge
<span class="since">Since 0.10.0</span>, 2) SRIOV Virtual
Functions (VF) used via type='hostdev' (direct device
assignment) <span class="since">Since 0.10.0</span>, and 3)
SRIOV VFs used via type='direct' with mode='passthrough'
(macvtap "passthru" mode) <span class="since">Since
1.3.5</span>. All other connection types, including standard
linux bridges and libvirt's own virtual networks, <b>do not</b>
support it. 802.1Qbh (vn-link) and 802.1Qbg (VEPA) switches
provide their own way (outside of libvirt) to tag guest traffic
onto a specific VLAN. Each tag is given in a
separate <code><tag></code> subelement
of <code><vlan></code> (for example: <code><tag
id='42'/></code>). For VLAN trunking of multiple tags (which
is supported only on Open vSwitch connections),
multiple <code><tag></code> subelements can be specified,
which implies that the user wants to do VLAN trunking on the
interface for all the specified tags. In the case that VLAN
trunking of a single tag is desired, the optional
attribute <code>trunk='yes'</code> can be added to the toplevel
<code><vlan></code> element to differentiate trunking of a
single tag from normal tagging.
</p>
<p>
For network connections using Open vSwitch it is also possible
to configure 'native-tagged' and 'native-untagged' VLAN modes
<span class="since">Since 1.1.0.</span> This is done with the
optional <code>nativeMode</code> attribute on
the <code><tag></code> subelement: <code>nativeMode</code>
may be set to 'tagged' or 'untagged'. The <code>id</code>
attribute of the <code><tag></code> subelement
containing <code>nativeMode</code> sets which VLAN is considered
to be the "native" VLAN for this interface, and
the <code>nativeMode</code> attribute determines whether or not
traffic for that VLAN will be tagged.
</p>
<h5>
<a id="elementLink">Modifying virtual link state</a>
<a class="headerlink" href="#elementLink" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet0'/>
<b><link state='down'/></b>
</interface>
</devices>
...</pre>
<p>
This element provides means of setting state of the virtual network link.
Possible values for attribute <code>state</code> are <code>up</code> and
<code>down</code>. If <code>down</code> is specified as the value, the interface
behaves as if it had the network cable disconnected. Default behavior if this
element is unspecified is to have the link state <code>up</code>.
<span class="since">Since 0.9.5</span>
</p>
<h5>
<a id="mtu">MTU configuration</a>
<a class="headerlink" href="#mtu" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet0'/>
<b><mtu size='1500'/></b>
</interface>
</devices>
...</pre>
<p>
This element provides means of setting MTU of the virtual network link.
Currently there is just one attribute <code>size</code> which accepts a
non-negative integer which specifies the MTU size for the interface.
<span class="since">Since 3.1.0</span>
</p>
<h5>
<a id="coalesce">Coalesce settings</a>
<a class="headerlink" href="#coalesce" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet0'/>
<b><coalesce>
<rx>
<frames max='7'/>
</rx>
</coalesce></b>
</interface>
</devices>
...</pre>
<p>
This element provides means of setting coalesce settings for
some interface devices (currently only type <code>network</code>
and <code>bridge</code>. Currently there is just one attribute,
<code>max</code>, to tweak, in element <code>frames</code> for
the <code>rx</code> group, which accepts a non-negative integer
that specifies the maximum number of packets that will be
received before an interrupt.
<span class="since">Since 3.3.0</span>
</p>
<h5>
<a id="ipconfig">IP configuration</a>
<a class="headerlink" href="#ipconfig" title="Permalink to this headline">¶</a>
</h5>
<pre>
...
<devices>
<interface type='network'>
<source network='default'/>
<target dev='vnet0'/>
<b><ip address='192.168.122.5' prefix='24'/></b>
<b><ip address='192.168.122.5' prefix='24' peer='10.0.0.10'/></b>
<b><route family='ipv4' address='192.168.122.0' prefix='24' gateway='192.168.122.1'/></b>
<b><route family='ipv4' address='192.168.122.8' gateway='192.168.122.1'/></b>
</interface>
...
<hostdev mode='capabilities' type='net'>
<source>
<interface>eth0</interface>
</source>
<b><ip address='192.168.122.6' prefix='24'/></b>
<b><route family='ipv4' address='192.168.122.0' prefix='24' gateway='192.168.122.1'/></b>
<b><route family='ipv4' address='192.168.122.8' gateway='192.168.122.1'/></b>
</hostdev>
...
</devices>
...
</pre>
<p><span class="since">Since 1.2.12</span> network devices and
hostdev devices with network capabilities can optionally be provided
one or more IP addresses to set on the network device in the
guest. Note that some hypervisors or network device types will
simply ignore them or only use the first one.
The <code>family</code> attribute can be set to
either <code>ipv4</code> or <code>ipv6</code>, and the
<code>address</code> attribute contains the IP address. The
optional <code>prefix</code> is the number of 1 bits in the
netmask, and will be automatically set if not specified - for
IPv4 the default prefix is determined according to the network
"class" (A, B, or C - see RFC870), and for IPv6 the default
prefix is 64. The optional <code>peer</code> attribute holds the
IP address of the other end of a point-to-point network
device <span class="since">(since 2.1.0)</span>.
</p>
<p><span class="since">Since 1.2.12</span> route elements can also be
added to define IP routes to add in the guest. The attributes of
this element are described in the documentation for
the <code>route</code> element
in <a href="formatnetwork.html#elementsStaticroute">network
definitions</a>. This is used by the LXC driver.
</p>
<pre>
...
<devices>
<interface type='ethernet'>
<b><source/></b>
<b><ip address='192.168.123.1' prefix='24'/></b>
<b><ip address='10.0.0.10' prefix='24' peer='192.168.122.5'/></b>
<b><route family='ipv4' address='192.168.42.0' prefix='24' gateway='192.168.123.4'/></b>
<b><source/></b>
...
</interface>
...
</devices>
...
</pre>
<p><span class="since">Since 2.1.0</span> network devices of type
"ethernet" can optionally be provided one or more IP addresses
and one or more routes to set on the <b>host</b> side of the
network device. These are configured as subelements of
the <code><source></code> element of the interface, and
have the same attributes as the similarly named elements used to
configure the guest side of the interface (described above).
</p>
<h5>
<a id="elementVhostuser">vhost-user interface</a>
<a class="headerlink" href="#elementVhostuser" title="Permalink to this headline">¶</a>
</h5>
<p><span class="since">Since 1.2.7</span> the vhost-user enables the
communication between a QEMU virtual machine and other userspace process
using the Virtio transport protocol. A char dev (e.g. Unix socket) is used
for the control plane, while the data plane is based on shared memory.
</p>
<pre>
...
<devices>
<interface type='vhostuser'>
<mac address='52:54:00:3b:83:1a'/>
<source type='unix' path='/tmp/vhost1.sock' mode='server'/>
<model type='virtio'/>
</interface>
<interface type='vhostuser'>
<mac address='52:54:00:3b:83:1b'/>
<source type='unix' path='/tmp/vhost2.sock' mode='client'>
<reconnect enabled='yes' timeout='10'/>
</source>
<model type='virtio'/>
<driver queues='5'/>
</interface>
</devices>
...</pre>
<p>
The <code><source></code> element has to be specified
along with the type of char device.
Currently, only type='unix' is supported, where the path (the
directory path of the socket) and mode attributes are required.
Both <code>mode='server'</code> and <code>mode='client'</code>
are supported.
vhost-user requires the virtio model type, thus the
<code><model></code> element is mandatory.
<span class="since">Since 4.1.0</span> the element has an
optional child element <code>reconnect</code> which
configures reconnect timeout if the connection is lost. It
has two attributes <code>enabled</code> (which accepts
<code>yes</code> and <code>no</code>) and
<code>timeout</code> which specifies the amount of seconds
after which hypervisor tries to reconnect.
</p>
<h5>
<a id="elementNwfilter">Traffic filtering with NWFilter</a>
<a class="headerlink" href="#elementNwfilter" title="Permalink to this headline">¶</a>
</h5>
<p><span class="since">Since 0.8.0</span> an <code>nwfilter</code> profile
can be assigned to a domain interface, which allows configuring
traffic filter rules for the virtual machine.
See the <a href="formatnwfilter.html">nwfilter</a> documentation for more
complete details.
</p>
<pre>
...
<devices>
<interface ...>
...
<filterref filter='clean-traffic'/>
</interface>
<interface ...>
...
<filterref filter='myfilter'>
<parameter name='IP' value='104.207.129.11'/>
<parameter name='IP6_ADDR' value='2001:19f0:300:2102::'/>
<parameter name='IP6_MASK' value='64'/>
...
</filterref>
</interface>
</devices>
...</pre>
<p>
The <code>filter</code> attribute specifies the name of the nwfilter
to use. Optional <code><parameter></code> elements may be
specified for passing additional info to the nwfilter via the
<code>name</code> and <code>value</code> attributes. See
the <a href="formatnwfilter.html#nwfconceptsvars">nwfilter</a>
docs for info on parameters.
</p>
<h4>
<a id="elementsInput">Input devices</a>
<a class="headerlink" href="#elementsInput" title="Permalink to this headline">¶</a>
</h4>
<p>
Input devices allow interaction with the graphical framebuffer
in the guest virtual machine. When enabling the framebuffer, an
input device is automatically provided. It may be possible to
add additional devices explicitly, for example,
to provide a graphics tablet for absolute cursor movement.
</p>
<pre>
...
<devices>
<input type='mouse' bus='usb'/>
<input type='keyboard' bus='usb'/>
<input type='mouse' bus='virtio'/>
<input type='keyboard' bus='virtio'/>
<input type='tablet' bus='virtio'/>
<input type='passthrough' bus='virtio'>
<source evdev='/dev/input/event1/>
</input>
</devices>
...</pre>
<dl>
<dt>
<code>input</code>
</dt>
<dd>The <code>input</code> element has one mandatory attribute,
the <code>type</code> whose value can be 'mouse', 'tablet',
(<span class="since">since 1.2.2</span>) 'keyboard' or
(<span class="since">since 1.3.0</span>) 'passthrough'.
The tablet provides absolute cursor movement,
while the mouse uses relative movement. The optional
<code>bus</code> attribute can be used to refine the exact device type.
It takes values "xen" (paravirtualized), "ps2" and "usb" or
(<span class="since">since 1.3.0</span>) "virtio".</dd>
</dl>
<p>
The <code>input</code> element has an optional
sub-element <code><address></code> which can tie the
device to a particular PCI
slot, <a href="#elementsAddress">documented above</a>.
On S390, <code>address</code> can be used to provide a CCW address for
an input device (<span class="since">since 4.2.0</span>).
For type <code>passthrough</code>, the mandatory sub-element <code>source</code>
must have an <code>evdev</code> attribute containing the absolute path to the
event device passed through to guests. (KVM only)
</p>
<p>
The subelement <code>driver</code> can be used to tune the virtio
options of the device:
<a href="#elementsVirtio">Virtio-specific options</a> can also be
set. (<span class="since">Since 3.5.0</span>)
</p>
<h4>
<a id="elementsHub">Hub devices</a>
<a class="headerlink" href="#elementsHub" title="Permalink to this headline">¶</a>
</h4>
<p>
A hub is a device that expands a single port into several so
that there are more ports available to connect devices to a host
system.
</p>
<pre>
...
<devices>
<hub type='usb'/>
</devices>
...</pre>
<dl>
<dt>
<code>hub</code>
</dt>
<dd>The <code>hub</code> element has one mandatory attribute,
the <code>type</code> whose value can only be 'usb'.</dd>
</dl>
<p>
The <code>hub</code> element has an optional
sub-element <code><address></code>
with <code>type='usb'</code>which can tie the device to a
particular controller, <a href="#elementsAddress">documented
above</a>.
</p>
<h4>
<a id="elementsGraphics">Graphical framebuffers</a>
<a class="headerlink" href="#elementsGraphics" title="Permalink to this headline">¶</a>
</h4>
<p>
A graphics device allows for graphical interaction with the
guest OS. A guest will typically have either a framebuffer
or a text console configured to allow interaction with the
admin.
</p>
<pre>
...
<devices>
<graphics type='sdl' display=':0.0'/>
<graphics type='vnc' port='5904' sharePolicy='allow-exclusive'>
<listen type='address' address='1.2.3.4'/>
</graphics>
<graphics type='rdp' autoport='yes' multiUser='yes' />
<graphics type='desktop' fullscreen='yes'/>
<graphics type='spice'>
<listen type='network' network='rednet'/>
</graphics>
</devices>
...</pre>
<dl>
<dt>
<code>graphics</code>
</dt>
<dd>
<p>
The <code>graphics</code> element has a mandatory <code>type</code>
attribute which takes the value <code>sdl</code>, <code>vnc</code>,
<code>spice</code>, <code>rdp</code>, <code>desktop</code> or
<code>egl-headless</code>:
</p>
<dl>
<dt>
<code>sdl</code>
</dt>
<dd>
<p>
This displays a window on the host desktop, it can take 3 optional
arguments: a <code>display</code> attribute for the display to use,
an <code>xauth</code> attribute for the authentication identifier,
and an optional <code>fullscreen</code> attribute accepting values
<code>yes</code> or <code>no</code>.
</p>
<p>
You can use a <code>gl</code> with the <code>enable="yes"</code>
property to enable OpenGL support in SDL. Likewise you can
explicitly disable OpenGL support with <code>enable="no"</code>.
</p>
</dd>
<dt>
<code>vnc</code>
</dt>
<dd>
<p>
Starts a VNC server. The <code>port</code> attribute specifies
the TCP port number (with -1 as legacy syntax indicating that it
should be auto-allocated). The <code>autoport</code> attribute is
the new preferred syntax for indicating auto-allocation of the TCP
port to use. The <code>passwd</code> attribute provides a VNC
password in clear text. If the <code>passwd</code> attribute is
set to an empty string, then VNC access is disabled. The
<code>keymap</code> attribute specifies the keymap to use. It is
possible to set a limit on the validity of the password by giving
a timestamp <code>passwdValidTo='2010-04-09T15:51:00'</code>
assumed to be in UTC. The <code>connected</code> attribute allows
control of connected client during password changes. VNC accepts
<code>keep</code> value only <span class="since">since 0.9.3</span>.
NB, this may not be supported by all hypervisors.
</p>
<p>
The optional <code>sharePolicy</code> attribute specifies vnc
server display sharing policy. <code>allow-exclusive</code> allows
clients to ask for exclusive access by dropping other connections.
Connecting multiple clients in parallel requires all clients asking
for a shared session (vncviewer: -Shared switch). This is
the default value. <code>force-shared</code> disables exclusive
client access, every connection has to specify -Shared switch for
vncviewer. <code>ignore</code> welcomes every connection
unconditionally <span class="since">since 1.0.6</span>.
</p>
<p>
Rather than using listen/port, QEMU supports a <code>socket</code>
attribute for listening on a unix domain socket path
<span class="since">Since 0.8.8</span>.
</p>
<p>
For VNC WebSocket functionality, <code>websocket</code> attribute
may be used to specify port to listen on (with -1 meaning
auto-allocation and <code>autoport</code> having no effect due to
security reasons) <span class="since">Since 1.0.6</span>.
</p>
<p>
Although VNC doesn't support OpenGL natively, it can be paired
with graphics type <code>egl-headless</code> (see below) which
will instruct QEMU to open and use drm nodes for OpenGL rendering.
</p>
</dd>
<dt>
<code>spice</code>
<span class="since">Since 0.8.6</span>
</dt>
<dd>
<p>
Starts a SPICE server. The <code>port</code> attribute specifies
the TCP port number (with -1 as legacy syntax indicating that it
should be auto-allocated), while <code>tlsPort</code> gives
an alternative secure port number. The <code>autoport</code>
attribute is the new preferred syntax for indicating
auto-allocation of needed port numbers. The <code>passwd</code>
attribute provides a SPICE password in clear text. If the
<code>passwd</code> attribute is set to an empty string, then
SPICE access is disabled. The <code>keymap</code> attribute
specifies the keymap to use. It is possible to set a limit on
the validity of the password by giving a timestamp
<code>passwdValidTo='2010-04-09T15:51:00'</code> assumed to be
in UTC.
</p>
<p>
The <code>connected</code> attribute allows control of connected
client during password changes. SPICE accepts <code>keep</code> to
keep client connected, <code>disconnect</code> to disconnect client
and <code>fail</code> to fail changing password . NB, this may not
be supported by all hypervisors.
<span class="since">Since 0.9.3</span>
</p>
<p>
The <code>defaultMode</code> attribute sets the default channel
security policy, valid values are <code>secure</code>,
<code>insecure</code> and the default <code>any</code> (which is
secure if possible, but falls back to insecure rather than erroring
out if no secure path is available).
<span class="since">Since 0.9.12</span>
</p>
<p>
When SPICE has both a normal and TLS secured TCP port configured,
it can be desirable to restrict what channels can be run on each
port. This is achieved by adding one or more <code><channel>
</code> elements inside the main <code><graphics></code>
element and setting the <code>mode</code> attribute to either
<code>secure</code> or <code>insecure</code>. Setting the mode
attribute overrides the default value as set by
the <code>defaultMode</code> attribute. (Note that specifying
<code>any</code> as mode discards the entry as the channel would
inherit the default mode anyways.) Valid channel names include
<code>main</code>, <code>display</code>, <code>inputs</code>,
<code>cursor</code>, <code>playback</code>, <code>record</code>
(all <span class="since"> since 0.8.6</span>);
<code>smartcard</code> (<span class="since">since 0.8.8</span>);
and <code>usbredir</code> (<span class="since">since 0.9.12</span>).
</p>
<pre>
<graphics type='spice' port='-1' tlsPort='-1' autoport='yes'>
<channel name='main' mode='secure'/>
<channel name='record' mode='insecure'/>
<image compression='auto_glz'/>
<streaming mode='filter'/>
<clipboard copypaste='no'/>
<mouse mode='client'/>
<filetransfer enable='no'/>
<gl enable='yes' rendernode='/dev/dri/by-path/pci-0000:00:02.0-render'/>
</graphics></pre>
<p>
Spice supports variable compression settings for audio, images and
streaming. These settings are accessible via the <code>compression
</code> attribute in all following elements: <code>image</code> to
set image compression (accepts <code>auto_glz</code>,
<code>auto_lz</code>, <code>quic</code>, <code>glz</code>,
<code>lz</code>, <code>off</code>), <code>jpeg</code> for JPEG
compression for images over wan (accepts <code>auto</code>,
<code>never</code>, <code>always</code>), <code>zlib</code> for
configuring wan image compression (accepts <code>auto</code>,
<code>never</code>, <code>always</code>) and <code>playback</code>
for enabling audio stream compression (accepts <code>on</code> or
<code>off</code>). <span class="since">Since 0.9.1</span>
</p>
<p>
Streaming mode is set by the <code>streaming</code> element,
settings its <code>mode</code> attribute to one of
<code>filter</code>, <code>all</code> or <code>off</code>.
<span class="since">Since 0.9.2</span>
</p>
<p>
Copy & Paste functionality (via Spice agent) is set by the
<code>clipboard</code> element. It is enabled by default, and can
be disabled by setting the <code>copypaste</code> property to
<code>no</code>. <span class="since">Since 0.9.3</span>
</p>
<p>
Mouse mode is set by the <code>mouse</code> element, setting its
<code>mode</code> attribute to one of <code>server</code> or
<code>client</code>. If no mode is specified, the qemu default will
be used (client mode). <span class="since">Since 0.9.11</span>
</p>
<p>
File transfer functionality (via Spice agent) is set using the
<code>filetransfer</code> element. It is enabled by default, and
can be disabled by setting the <code>enable</code> property to
<code>no</code>. <span class="since">Since 1.2.2</span>
</p>
<p>
Spice may provide accelerated server-side rendering with OpenGL.
You can enable or disable OpenGL support explicitly with
the <code>gl</code> element, by setting the <code>enable</code>
property. (QEMU only, <span class="since">since 1.3.3</span>).
Note that this only works locally, since this requires usage of
UNIX sockets, i.e. using <code>listen</code> types 'socket' or
'none'. For accelerated OpenGL with remote support, consider
pairing this element with type <code>egl-headless</code>
(see below). However, this will deliver weaker performance
compared to native Spice OpenGL support.
</p>
<p>
By default, QEMU will pick the first available GPU DRM render node.
You may specify a DRM render node path to use instead. (QEMU only,
<span class="since">since 3.1.0</span>).
</p>
</dd>
<dt>
<code>rdp</code>
</dt>
<dd>
<p>
Starts a RDP server. The <code>port</code> attribute specifies the
TCP port number (with -1 as legacy syntax indicating that it should
be auto-allocated). The <code>autoport</code> attribute is the new
preferred syntax for indicating auto-allocation of the TCP port to
use. In the VirtualBox driver, the <code>autoport</code> will make
the hypervisor pick available port from 3389-3689 range when the VM
is started. The chosen port will be reflected in the <code>port</code>
attribute. The <code>multiUser</code> attribute is a boolean deciding
whether multiple simultaneous connections to the VM are permitted.
The <code>replaceUser</code> attribute is a boolean deciding whether
the existing connection must be dropped and a new connection must
be established by the VRDP server, when a new client connects in
single connection mode.
</p>
</dd>
<dt>
<code>desktop</code>
</dt>
<dd>
<p>
This value is reserved for VirtualBox domains for the moment. It
displays a window on the host desktop, similarly to "sdl", but
using the VirtualBox viewer. Just like "sdl", it accepts
the optional attributes <code>display</code> and
<code>fullscreen</code>.
</p>
</dd>
<dt>
<code>egl-headless</code>
<span class="since">Since 4.6.0</span>
</dt>
<dd>
<p>
This display type provides support for an OpenGL accelerated
display accessible both locally and remotely (for comparison,
Spice's native OpenGL support only works locally using UNIX
sockets at the moment, but has better performance). Since this
display type doesn't provide any window or graphical console like
the other types, for practical reasons it should be paired with
either <code>vnc</code> or <code>spice</code> graphics types.
This display type is only supported by QEMU domains
(needs QEMU <span class="since">2.10</span> or newer).
<span class="Since">5.0.0</span> this element accepts a
<code><gl/></code> sub-element with an optional attribute
<code>rendernode</code> which can be used to specify an absolute
path to a host's DRI device to be used for OpenGL rendering.
</p>
<pre>
<graphics type='spice' autoport='yes'/>
<graphics type='egl-headless'>
<gl rendernode='/dev/dri/renderD128'/>
</graphics>
</pre>
</dd>
</dl>
</dd>
</dl>
<p>
Graphics device uses a <code><listen></code> to set up where
the device should listen for clients. It has a mandatory attribute
<code>type</code> which specifies the listen type. Only <code>vnc</code>,
<code>spice</code> and <code>rdp</code> supports <code><listen>
</code> element. <span class="since">Since 0.9.4</span>.
Available types are:
</p>
<dl>
<dt>
<code>address</code>
</dt>
<dd>
<p>
Tells a graphics device to use an address specified in the
<code>address</code> attribute, which will contain either an IP address
or hostname (which will be resolved to an IP address via a DNS query)
to listen on.
</p>
<p>
It is possible to omit the <code>address</code> attribute in order to
use an address from config files <span class="since">Since 1.3.5</span>.
</p>
<p>
The <code>address</code> attribute is duplicated as <code>listen</code>
attribute in <code>graphics</code> element for backward compatibility.
If both are provided they must be equal.
</p>
</dd>
<dt>
<code>network</code>
</dt>
<dd>
<p>
This is used to specify an existing network in the <code>network</code>
attribute from libvirt's list of configured networks. The named network
configuration will be examined to determine an appropriate listen
address and the address will be stored in live XML in <code>address
</code> attribute. For example, if the network has an IPv4 address in
its configuration (e.g. if it has a forward type of <code>route</code>,
<code>nat</code>, or no forward type (isolated)), the first IPv4
address listed in the network's configuration will be used.
If the network is describing a host bridge, the first IPv4 address
associated with that bridge device will be used, and if the network is
describing one of the 'direct' (macvtap) modes, the first IPv4 address
of the first forward dev will be used.
</p>
</dd>
<dt>
<code>socket</code>
<span class="since">since 2.0.0 (QEMU only)</span>
</dt>
<dd>
<p>
This listen type tells a graphics server to listen on unix socket.
Attribute <code>socket</code> contains a path to unix socket. If this
attribute is omitted libvirt will generate this path for you.
Supported by graphics type <code>vnc</code> and <code>spice</code>.
</p>
<p>
For <code>vnc</code> graphics be backward compatible
the <code>socket</code> attribute of first <code>listen</code> element
is duplicated as <code>socket</code> attribute in <code>graphics</code>
element. If <code>graphics</code> element contains a <code>socket</code>
attribute all <code>listen</code> elements are ignored.
</p>
</dd>
<dt>
<code>none</code>
<span class="since">since 2.0.0 (QEMU only)</span>
</dt>
<dd>
<p>
This listen type doesn't have any other attribute. Libvirt supports
passing a file descriptor through our APIs virDomainOpenGraphics() and
virDomainOpenGraphicsFD(). No other listen types are allowed if this
one is used and the graphics device doesn't listen anywhere. You need
to use one of the two APIs to pass a FD to QEMU in order to connect to
this graphics device. Supported by graphics type <code>vnc</code> and
<code>spice</code>.
</p>
</dd>
</dl>
<h4>
<a id="elementsVideo">Video devices</a>
<a class="headerlink" href="#elementsVideo" title="Permalink to this headline">¶</a>
</h4>
<p>
A video device.
</p>
<pre>
...
<devices>
<video>
<model type='vga' vram='16384' heads='1'>
<acceleration accel3d='yes' accel2d='yes'/>
</model>
</video>
</devices>
...</pre>
<dl>
<dt>
<code>video</code>
</dt>
<dd>
<p>
The <code>video</code> element is the container for describing
video devices. For backwards compatibility, if no <code>video</code>
is set but there is a <code>graphics</code> in domain xml, then
libvirt will add a default <code>video</code> according to the guest
type.
</p>
<p>
For a guest of type "kvm", the default <code>video</code> is:
<code>type</code> with value "cirrus", <code>vram</code> with value
"16384" and <code>heads</code> with value "1". By default, the first
video device in domain xml is the primary one, but the optional
attribute <code>primary</code> (<span class="since">since 1.0.2</span>)
with value 'yes' can be used to mark the primary in cases of multiple
video device. The non-primary must be type of "qxl" or
(<span class="since">since 2.4.0</span>) "virtio".
</p>
</dd>
<dt>
<code>model</code>
</dt>
<dd>
<p>
The <code>model</code> element has a mandatory <code>type</code>
attribute which takes the value "vga", "cirrus", "vmvga", "xen",
"vbox", "qxl" (<span class="since">since 0.8.6</span>),
"virtio" (<span class="since">since 1.3.0</span>),
"gop" (<span class="since">since 3.2.0</span>), or
"none" (<span class="since">since 4.6.0</span>)
depending on the hypervisor features available.
The purpose of the type <code>none</code> is to instruct libvirt not
to add a default video device in the guest (see the paragraph above).
This legacy behaviour can be inconvenient in cases where GPU mediated
devices are meant to be the only rendering device within a guest and
so specifying another <code>video</code> device along with type
<code>none</code>.
Refer to <a id="elementsHostDev">Host device assignment</a> to see
how to add a mediated device into a guest.
</p>
<p>
You can provide the amount of video memory in kibibytes (blocks of
1024 bytes) using <code>vram</code>. This is supported only for guest
type of "libxl", "vz", "qemu", "vbox", "vmx" and "xen". If no
value is provided the default is used. If the size is not a power of
two it will be rounded to closest one.
</p>
<p>
The number of screen can be set using <code>heads</code>. This is
supported only for guests type of "vz", "kvm", "vbox" and "vmx".
</p>
<p>
For guest type of "kvm" or "qemu" and model type "qxl" there are
optional attributes. Attribute <code>ram</code> (<span class="since">
since 1.0.2</span>) specifies the size of the primary bar, while the
attribute <code>vram</code> specifies the secondary bar size.
If <code>ram</code> or <code>vram</code> are not supplied a default
value is used. The <code>ram</code> should also be rounded to power of
two as <code>vram</code>. There is also optional attribute
<code>vgamem</code> (<span class="since">since 1.2.11</span>) to set
the size of VGA framebuffer for fallback mode of QXL device.
Attribute <code>vram64</code> (<span class="since">since 1.3.3</span>)
extends secondary bar and makes it addressable as 64bit memory.
</p>
</dd>
<dt>
<code>acceleration</code>
</dt>
<dd>
Configure if video acceleration should be enabled.
<dl><dt><code>accel2d</code></dt><dd>Enable 2D acceleration (for vbox driver only,
<span class="since">since 0.7.1</span>)</dd><dt><code>accel3d</code></dt><dd>Enable 3D acceleration (for vbox driver
<span class="since">since 0.7.1</span>, qemu driver
<span class="since">since 1.3.0</span>)</dd></dl>
</dd>
<dt>
<code>address</code>
</dt>
<dd>
The optional <code>address</code> sub-element can be used to
tie the video device to a particular PCI slot.
On S390, <code>address</code> can be used to provide the
CCW address for the video device (<span class="since">
since 4.2.0</span>).
</dd>
<dt>
<code>driver</code>
</dt>
<dd>
The subelement <code>driver</code> can be used to tune the device:
<dl><dt>virtio options</dt><dd><a href="#elementsVirtio">Virtio-specific options</a> can also be
set (<span class="since">Since 3.5.0</span>)
</dd><dt>VGA configuration</dt><dd>
Control how the video devices exposed to the guest using the
<code>vgaconf</code> attribute which takes the value "io", "on" or "off".
At present, it's only applicable to the bhyve's "gop" video model type
(<span class="since">Since 3.5.0</span>)
</dd></dl>
</dd>
</dl>
<h4>
<a id="elementsConsole">Consoles, serial, parallel & channel devices</a>
<a class="headerlink" href="#elementsConsole" title="Permalink to this headline">¶</a>
</h4>
<p>
A character device provides a way to interact with the virtual machine.
Paravirtualized consoles, serial ports, parallel ports and channels are
all classed as character devices and so represented using the same syntax.
</p>
<pre>
...
<devices>
<parallel type='pty'>
<source path='/dev/pts/2'/>
<target port='0'/>
</parallel>
<serial type='pty'>
<source path='/dev/pts/3'/>
<target port='0'/>
</serial>
<serial type='file'>
<source path='/tmp/file' append='on'>
<seclabel model='dac' relabel='no'/>
</source>
<target port='0'/>
</serial>
<console type='pty'>
<source path='/dev/pts/4'/>
<target port='0'/>
</console>
<channel type='unix'>
<source mode='bind' path='/tmp/guestfwd'/>
<target type='guestfwd' address='10.0.2.1' port='4600'/>
</channel>
</devices>
...</pre>
<p>
In each of these directives, the top-level element name (parallel, serial,
console, channel) describes how the device is presented to the guest. The
guest interface is configured by the <code>target</code> element.
</p>
<p>
The interface presented to the host is given in the <code>type</code>
attribute of the top-level element. The host interface is
configured by the <code>source</code> element.
</p>
<p>
The <code>source</code> element may contain an optional
<code>seclabel</code> to override the way that labelling
is done on the socket path. If this element is not present,
the <a href="#seclabel">security label is inherited from
the per-domain setting</a>.
</p>
<p>
If the interface <code>type</code> presented to the host is "file",
then the <code>source</code> element may contain an optional attribute
<code>append</code> that specifies whether or not the information in
the file should be preserved on domain restart. Allowed values are
"on" and "off" (default). <span class="since">Since 1.3.1</span>.
</p>
<p>
Regardless of the <code>type</code>, character devices can
have an optional log file associated with them. This is
expressed via a <code>log</code> sub-element, with a
<code>file</code> attribute. There can also be an <code>append</code>
attribute which takes the same values described above.
<span class="since">Since 1.3.3</span>.
</p>
<pre>
...
<log file="/var/log/libvirt/qemu/guestname-serial0.log" append="off"/>
...</pre>
<p>
Each character device element has an optional
sub-element <code><address></code> which can tie the
device to a
particular <a href="#elementsControllers">controller</a> or PCI
slot.
</p>
<p>
For character device with type <code>unix</code> or <code>tcp</code>
the <code>source</code> has an optional element <code>reconnect</code>
which configures reconnect timeout if the connection is lost.
There are two attributes, <code>enabled</code> where possible
values are "yes" and "no" and <code>timeout</code> which is in
seconds. The <code>reconnect</code> attribute is valid only
for <code>connect</code> mode.
<span class="since">Since 3.7.0 (QEMU driver only)</span>.
</p>
<h5>
<a id="elementsCharGuestInterface">Guest interface</a>
<a class="headerlink" href="#elementsCharGuestInterface" title="Permalink to this headline">¶</a>
</h5>
<p>
A character device presents itself to the guest as one of the following
types.
</p>
<h6>
<a id="elementCharParallel">Parallel port</a>
<a class="headerlink" href="#elementCharParallel" title="Permalink to this headline">¶</a>
</h6>
<pre>
...
<devices>
<parallel type='pty'>
<source path='/dev/pts/2'/>
<target port='0'/>
</parallel>
</devices>
...</pre>
<p><code>target</code> can have a <code>port</code> attribute, which
specifies the port number. Ports are numbered starting from 0. There are
usually 0, 1 or 2 parallel ports.
</p>
<h6>
<a id="elementCharSerial">Serial port</a>
<a class="headerlink" href="#elementCharSerial" title="Permalink to this headline">¶</a>
</h6>
<pre>
...
<devices>
<!-- Serial port -->
<serial type='pty'>
<source path='/dev/pts/3'/>
<target port='0'/>
</serial>
</devices>
...</pre>
<pre>
...
<devices>
<!-- USB serial port -->
<serial type='pty'>
<target type='usb-serial' port='0'>
<model name='usb-serial'/>
</target>
<address type='usb' bus='0' port='1'/>
</serial>
</devices>
...</pre>
<p>
The <code>target</code> element can have an optional <code>port</code>
attribute, which specifies the port number (starting from 0), and an
optional <code>type</code> attribute: valid values are,
<span class="since">since 1.0.2</span>, <code>isa-serial</code> (usable
with x86 guests), <code>usb-serial</code> (usable whenever USB support
is available) and <code>pci-serial</code> (usable whenever PCI support
is available); <span class="since">since 3.10.0</span>,
<code>spapr-vio-serial</code> (usable with ppc64/pseries guests),
<code>system-serial</code> (usable with aarch64/virt and,
<span class="since">since 4.7.0</span>, riscv/virt guests) and
<code>sclp-serial</code> (usable with s390 and s390x guests) are
available as well.
</p>
<p><span class="since">Since 3.10.0</span>, the <code>target</code>
element can have an optional <code>model</code> subelement;
valid values for its <code>name</code> attribute are:
<code>isa-serial</code> (usable with the <code>isa-serial</code> target
type); <code>usb-serial</code> (usable with the <code>usb-serial</code>
target type); <code>pci-serial</code>
(usable with the <code>pci-serial</code> target type);
<code>spapr-vty</code> (usable with the <code>spapr-vio-serial</code>
target type); <code>pl011</code> and,
<span class="since">since 4.7.0</span>, <code>16550a</code> (usable
with the <code>system-serial</code> target type);
<code>sclpconsole</code> and <code>sclplmconsole</code> (usable with
the <code>sclp-serial</code> target type).
</p>
<p>
If any of the attributes is not specified by the user, libvirt will
choose a value suitable for most users.
</p>
<p>
Most target types support configuring the guest-visible device
address as <a href="#elementsAddress">documented above</a>; more
specifically, acceptable address types are <code>isa</code> (for
<code>isa-serial</code>), <code>usb</code> (for <code>usb-serial</code>),
<code>pci</code> (for <code>pci-serial</code>) and <code>spapr-vio</code>
(for <code>spapr-vio-serial</code>). The <code>system-serial</code>
and <code>sclp-serial</code> target types don't support specifying an
address.
</p>
<p>
For the relationship between serial ports and consoles,
<a href="#elementCharSerialAndConsole">see below</a>.
</p>
<h6>
<a id="elementCharConsole">Console</a>
<a class="headerlink" href="#elementCharConsole" title="Permalink to this headline">¶</a>
</h6>
<pre>
...
<devices>
<!-- Serial console -->
<console type='pty'>
<source path='/dev/pts/2'/>
<target type='serial' port='0'/>
</console>
</devices>
...</pre>
<pre>
...
<devices>
<!-- KVM virtio console -->
<console type='pty'>
<source path='/dev/pts/5'/>
<target type='virtio' port='0'/>
</console>
</devices>
...</pre>
<p>
The <code>console</code> element is used to represent interactive
serial consoles. Depending on the type of guest in use and the specifics
of the configuration, the <code>console</code> element might represent
the same device as an existing <code>serial</code> element or a separate
device.
</p>
<p>
A <code>target</code> subelement is supported and works the same
way as with the <code>serial</code> element
(<a href="#elementCharSerial">see above</a> for details).
Valid values for the <code>type</code> attribute are:
<code>serial</code> (described below);
<code>virtio</code> (usable whenever VirtIO support is available);
<code>xen</code>, <code>lxc</code> and <code>openvz</code>
(available when the corresponding hypervisor is in use).
<code>sclp</code> and <code>sclplm</code> (usable for s390 and
s390x QEMU guests) are supported for compatibility reasons but should
not be used for new guests: use the <code>sclpconsole</code> and
<code>sclplmconsole</code> target models, respectively, with the
<code>serial</code> element instead.
</p>
<p>
Of the target types listed above, <code>serial</code> is special in
that it doesn't represents a separate device, but rather the same
device as the first <code>serial</code> element. Due to this, there can
only be a single <code>console</code> element with target type
<code>serial</code> per guest.
</p>
<p>
Virtio consoles are usually accessible as <code>/dev/hvc[0-7]</code>
from inside the guest; for more information, see
<a href="http://fedoraproject.org/wiki/Features/VirtioSerial">http://fedoraproject.org/wiki/Features/VirtioSerial</a>.
<span class="since">Since 0.8.3</span>
</p>
<p>
For the relationship between serial ports and consoles,
<a href="#elementCharSerialAndConsole">see below</a>.
</p>
<h6>
<a id="elementCharSerialAndConsole">Relationship between serial ports and consoles</a>
<a class="headerlink" href="#elementCharSerialAndConsole" title="Permalink to this headline">¶</a>
</h6>
<p>
Due to hystorical reasons, the <code>serial</code> and
<code>console</code> elements have partially overlapping scopes.
</p>
<p>
In general, both elements are used to configure one or more serial
consoles to be used for interacting with the guest. The main difference
between the two is that <code>serial</code> is used for emulated,
usually native, serial consoles, whereas <code>console</code> is used
for paravirtualized ones.
</p>
<p>
Both emulated and paravirtualized serial consoles have advantages and
disadvantages:
</p>
<ul>
<li>
emulated serial consoles are usually initialized much earlier than
paravirtualized ones, so they can be used to control the bootloader
and display both firmware and early boot messages;
</li>
<li>
on several platforms, there can only be a single emulated serial
console per guest but paravirtualized consoles don't suffer from the
same limitation.
</li>
</ul>
<p>
A configuration such as:
</p>
<pre>
...
<devices>
<console type='pty'>
<target type='serial'/>
</console>
<console type='pty'>
<target type='virtio'/>
</console>
</devices>
...</pre>
<p>
will work on any platform and will result in one emulated serial console
for early boot logging / interactive / recovery use, and one
paravirtualized serial console to be used eg. as a side channel. Most
people will be fine with having just the first <code>console</code>
element in their configuration.
</p>
<p>
Note that, due to the compatibility concerns mentioned earlier, all the
following configurations:
</p>
<pre>
...
<devices>
<serial type='pty'/>
</devices>
...</pre>
<pre>
...
<devices>
<console type='pty'/>
</devices>
...</pre>
<pre>
...
<devices>
<serial type='pty'/>
<console type='pty'/>
</devices>
...</pre>
<p>
will be treated the same and will result in a single emulated serial
console being available to the guest.
</p>
<h6>
<a id="elementCharChannel">Channel</a>
<a class="headerlink" href="#elementCharChannel" title="Permalink to this headline">¶</a>
</h6>
<p>
This represents a private communication channel between the host and the
guest.
</p>
<pre>
...
<devices>
<channel type='unix'>
<source mode='bind' path='/tmp/guestfwd'/>
<target type='guestfwd' address='10.0.2.1' port='4600'/>
</channel>
<!-- KVM virtio channel -->
<channel type='pty'>
<target type='virtio' name='arbitrary.virtio.serial.port.name'/>
</channel>
<channel type='unix'>
<source mode='bind' path='/var/lib/libvirt/qemu/f16x86_64.agent'/>
<target type='virtio' name='org.qemu.guest_agent.0' state='connected'/>
</channel>
<channel type='spicevmc'>
<target type='virtio' name='com.redhat.spice.0'/>
</channel>
</devices>
...</pre>
<p>
This can be implemented in a variety of ways. The specific type of
channel is given in the <code>type</code> attribute of the
<code>target</code> element. Different channel types have different
<code>target</code> attributes.
</p>
<dl>
<dt>
<code>guestfwd</code>
</dt>
<dd>TCP traffic sent by the guest to a given IP address and port is
forwarded to the channel device on the host. The <code>target</code>
element must have <code>address</code> and <code>port</code> attributes.
<span class="since">Since 0.7.3</span></dd>
<dt>
<code>virtio</code>
</dt>
<dd>Paravirtualized virtio channel. Channel is exposed in the guest under
/dev/vport*, and if the optional element <code>name</code> is specified,
/dev/virtio-ports/$name (for more info, please see
<a href="http://fedoraproject.org/wiki/Features/VirtioSerial">http://fedoraproject.org/wiki/Features/VirtioSerial</a>). The
optional element <code>address</code> can tie the channel to a
particular <code>type='virtio-serial'</code>
controller, <a href="#elementsAddress">documented above</a>.
With qemu, if <code>name</code> is "org.qemu.guest_agent.0",
then libvirt can interact with a guest agent installed in the
guest, for actions such as guest shutdown or file system quiescing.
<span class="since">Since 0.7.7, guest agent interaction
since 0.9.10</span> Moreover, <span class="since">since 1.0.6</span>
it is possible to have source path auto generated for virtio unix channels.
This is very useful in case of a qemu guest agent, where users don't
usually care about the source path since it's libvirt who talks to
the guest agent. In case users want to utilize this feature, they should
leave <code><source></code> element out. <span class="since">Since
1.2.11</span> the active XML for a virtio channel may contain an optional
<code>state</code> attribute that reflects whether a process in the
guest is active on the channel. This is an output-only attribute.
Possible values for the <code>state</code> attribute are
<code>connected</code> and <code>disconnected</code>.
</dd>
<dt>
<code>xen</code>
</dt>
<dd> Paravirtualized Xen channel. Channel is exposed in the guest as a
Xen console but identified with a name. Setup and consumption of a Xen
channel depends on software and configuration in the guest
(for more info, please see <a href="http://xenbits.xen.org/docs/unstable/misc/channel.txt">http://xenbits.xen.org/docs/unstable/misc/channel.txt</a>).
Channel source path semantics are the same as the virtio target type.
The <code>state</code> attribute is not supported since Xen channels
lack the necessary probing mechanism.
<span class="since">Since 2.3.0</span>
</dd>
<dt>
<code>spicevmc</code>
</dt>
<dd>Paravirtualized SPICE channel. The domain must also have a
SPICE server as a <a href="#elementsGraphics">graphics
device</a>, at which point the host piggy-backs messages
across the <code>main</code> channel. The <code>target</code>
element must be present, with
attribute <code>type='virtio'</code>; an optional
attribute <code>name</code> controls how the guest will have
access to the channel, and defaults
to <code>name='com.redhat.spice.0'</code>. The
optional <code>address</code> element can tie the channel to a
particular <code>type='virtio-serial'</code> controller.
<span class="since">Since 0.8.8</span></dd>
</dl>
<h5>
<a id="elementsCharHostInterface">Host interface</a>
<a class="headerlink" href="#elementsCharHostInterface" title="Permalink to this headline">¶</a>
</h5>
<p>
A character device presents itself to the host as one of the following
types.
</p>
<h6>
<a id="elementsCharSTDIO">Domain logfile</a>
<a class="headerlink" href="#elementsCharSTDIO" title="Permalink to this headline">¶</a>
</h6>
<p>
This disables all input on the character device, and sends output
into the virtual machine's logfile
</p>
<pre>
...
<devices>
<console type='stdio'>
<target port='1'/>
</console>
</devices>
...</pre>
<h6>
<a id="elementsCharFle">Device logfile</a>
<a class="headerlink" href="#elementsCharFle" title="Permalink to this headline">¶</a>
</h6>
<p>
A file is opened and all data sent to the character
device is written to the file.
</p>
<pre>
...
<devices>
<serial type="file">
<source path="/var/log/vm/vm-serial.log"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a id="elementsCharVC">Virtual console</a>
<a class="headerlink" href="#elementsCharVC" title="Permalink to this headline">¶</a>
</h6>
<p>
Connects the character device to the graphical framebuffer in
a virtual console. This is typically accessed via a special
hotkey sequence such as "ctrl+alt+3"
</p>
<pre>
...
<devices>
<serial type='vc'>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a id="elementsCharNull">Null device</a>
<a class="headerlink" href="#elementsCharNull" title="Permalink to this headline">¶</a>
</h6>
<p>
Connects the character device to the void. No data is ever
provided to the input. All data written is discarded.
</p>
<pre>
...
<devices>
<serial type='null'>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a id="elementsCharPTY">Pseudo TTY</a>
<a class="headerlink" href="#elementsCharPTY" title="Permalink to this headline">¶</a>
</h6>
<p>
A Pseudo TTY is allocated using /dev/ptmx. A suitable client
such as 'virsh console' can connect to interact with the
serial port locally.
</p>
<pre>
...
<devices>
<serial type="pty">
<source path="/dev/pts/3"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<p>
NB special case if <console type='pty'>, then the TTY
path is also duplicated as an attribute tty='/dev/pts/3'
on the top level <console> tag. This provides compat
with existing syntax for <console> tags.
</p>
<h6>
<a id="elementsCharHost">Host device proxy</a>
<a class="headerlink" href="#elementsCharHost" title="Permalink to this headline">¶</a>
</h6>
<p>
The character device is passed through to the underlying
physical character device. The device types must match,
eg the emulated serial port should only be connected to
a host serial port - don't connect a serial port to a parallel
port.
</p>
<pre>
...
<devices>
<serial type="dev">
<source path="/dev/ttyS0"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a id="elementsCharPipe">Named pipe</a>
<a class="headerlink" href="#elementsCharPipe" title="Permalink to this headline">¶</a>
</h6>
<p>
The character device writes output to a named pipe. See pipe(7) for
more info.
</p>
<pre>
...
<devices>
<serial type="pipe">
<source path="/tmp/mypipe"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a id="elementsCharTCP">TCP client/server</a>
<a class="headerlink" href="#elementsCharTCP" title="Permalink to this headline">¶</a>
</h6>
<p>
The character device acts as a TCP client connecting to a
remote server.
</p>
<pre>
...
<devices>
<serial type="tcp">
<source mode="connect" host="0.0.0.0" service="2445"/>
<protocol type="raw"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<p>
Or as a TCP server waiting for a client connection.
</p>
<pre>
...
<devices>
<serial type="tcp">
<source mode="bind" host="127.0.0.1" service="2445"/>
<protocol type="raw"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<p>
Alternatively you can use <code>telnet</code> instead
of <code>raw</code> TCP in order to utilize the telnet protocol
for the connection.
</p>
<p><span class="since">Since 0.8.5,</span> some hypervisors support
use of either <code>telnets</code> (secure telnet) or <code>tls</code>
(via secure sockets layer) as the transport protocol for connections.
</p>
<pre>
...
<devices>
<serial type="tcp">
<source mode="connect" host="0.0.0.0" service="2445"/>
<protocol type="telnet"/>
<target port="1"/>
</serial>
...
<serial type="tcp">
<source mode="bind" host="127.0.0.1" service="2445"/>
<protocol type="telnet"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<p><span class="since">Since 2.4.0,</span> the optional attribute
<code>tls</code> can be used to control whether a chardev
TCP communication channel would utilize a hypervisor configured
TLS X.509 certificate environment in order to encrypt the data
channel. For the QEMU hypervisor, usage of a TLS environment can
be controlled on the host by the <code>chardev_tls</code> and
<code>chardev_tls_x509_cert_dir</code> or
<code>default_tls_x509_cert_dir</code> settings in the file
/etc/libvirt/qemu.conf. If <code>chardev_tls</code> is enabled,
then unless the <code>tls</code> attribute is set to "no", libvirt
will use the host configured TLS environment.
If <code>chardev_tls</code> is disabled, but the <code>tls</code>
attribute is set to "yes", then libvirt will attempt to use the
host TLS environment if either the <code>chardev_tls_x509_cert_dir</code>
or <code>default_tls_x509_cert_dir</code> TLS directory structure exists.
</p>
<pre>
...
<devices>
<serial type="tcp">
<source mode='connect' host="127.0.0.1" service="5555" tls="yes"/>
<protocol type="raw"/>
<target port="0"/>
</serial>
</devices>
...</pre>
<h6>
<a id="elementsCharUDP">UDP network console</a>
<a class="headerlink" href="#elementsCharUDP" title="Permalink to this headline">¶</a>
</h6>
<p>
The character device acts as a UDP netconsole service,
sending and receiving packets. This is a lossy service.
</p>
<pre>
...
<devices>
<serial type="udp">
<source mode="bind" host="0.0.0.0" service="2445"/>
<source mode="connect" host="0.0.0.0" service="2445"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a id="elementsCharUNIX">UNIX domain socket client/server</a>
<a class="headerlink" href="#elementsCharUNIX" title="Permalink to this headline">¶</a>
</h6>
<p>
The character device acts as a UNIX domain socket server,
accepting connections from local clients.
</p>
<pre>
...
<devices>
<serial type="unix">
<source mode="bind" path="/tmp/foo"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a id="elementsCharSpiceport">Spice channel</a>
<a class="headerlink" href="#elementsCharSpiceport" title="Permalink to this headline">¶</a>
</h6>
<p>
The character device is accessible through spice connection
under a channel name specified in the <code>channel</code>
attribute. <span class="since">Since 1.2.2</span>
</p>
<p>
Note: depending on the hypervisor, spiceports might (or might not)
be enabled on domains with or without <a href="#elementsGraphics">spice
graphics</a>.
</p>
<pre>
...
<devices>
<serial type="spiceport">
<source channel="org.qemu.console.serial.0"/>
<target port="1"/>
</serial>
</devices>
...</pre>
<h6>
<a id="elementsNmdm">Nmdm device</a>
<a class="headerlink" href="#elementsNmdm" title="Permalink to this headline">¶</a>
</h6>
<p>
The nmdm device driver, available on FreeBSD, provides two
tty devices connected together by a virtual null modem cable.
<span class="since">Since 1.2.4</span>
</p>
<pre>
...
<devices>
<serial type="nmdm">
<source master="/dev/nmdm0A" slave="/dev/nmdm0B"/>
</serial>
</devices>
...</pre>
<p>
The <code>source</code> element has these attributes:
</p>
<dl>
<dt>
<code>master</code>
</dt>
<dd>Master device of the pair, that is passed to the hypervisor.
Device is specified by a fully qualified path.</dd>
<dt>
<code>slave</code>
</dt>
<dd>Slave device of the pair, that is passed to the clients for connection
to the guest console. Device is specified by a fully qualified path.</dd>
</dl>
<h4>
<a id="elementsSound">Sound devices</a>
<a class="headerlink" href="#elementsSound" title="Permalink to this headline">¶</a>
</h4>
<p>
A virtual sound card can be attached to the host via the
<code>sound</code> element. <span class="since">Since 0.4.3</span>
</p>
<pre>
...
<devices>
<sound model='es1370'/>
</devices>
...</pre>
<dl>
<dt>
<code>sound</code>
</dt>
<dd>
The <code>sound</code> element has one mandatory attribute,
<code>model</code>, which specifies what real sound device is emulated.
Valid values are specific to the underlying hypervisor, though typical
choices are 'es1370', 'sb16', 'ac97', 'ich6' and 'usb'.
(<span class="since">
'ac97' only since 0.6.0, 'ich6' only since 0.8.8,
'usb' only since 1.2.7</span>)
</dd>
</dl>
<p><span class="since">Since 0.9.13</span>, a sound element
with <code>ich6</code> model can have optional
sub-elements <code><codec></code> to attach various audio
codecs to the audio device. If not specified, a default codec
will be attached to allow playback and recording.
</p>
<p>
Valid values are:
</p>
<p>
<ul>
<li>'duplex' - advertise a line-in and a line-out </li>
<li>'micro' - advertise a speaker and a microphone </li>
<li>'output' - advertise a line-out
<span class="since">Since 4.4.0</span></li>
</ul>
</p>
<pre>
...
<devices>
<sound model='ich6'>
<codec type='micro'/>
</sound>
</devices>
...</pre>
<p>
Each <code>sound</code> element has an optional
sub-element <code><address></code> which can tie the
device to a particular PCI
slot, <a href="#elementsAddress">documented above</a>.
</p>
<h4>
<a id="elementsWatchdog">Watchdog device</a>
<a class="headerlink" href="#elementsWatchdog" title="Permalink to this headline">¶</a>
</h4>
<p>
A virtual hardware watchdog device can be added to the guest via
the <code>watchdog</code> element.
<span class="since">Since 0.7.3, QEMU and KVM only</span>
</p>
<p>
The watchdog device requires an additional driver and management
daemon in the guest. Just enabling the watchdog in the libvirt
configuration does not do anything useful on its own.
</p>
<p>
Currently libvirt does not support notification when the
watchdog fires. This feature is planned for a future version of
libvirt.
</p>
<pre>
...
<devices>
<watchdog model='i6300esb'/>
</devices>
...</pre>
<pre>
...
<devices>
<watchdog model='i6300esb' action='poweroff'/>
</devices>
</domain></pre>
<dl>
<dt>
<code>model</code>
</dt>
<dd>
<p>
The required <code>model</code> attribute specifies what real
watchdog device is emulated. Valid values are specific to the
underlying hypervisor.
</p>
<p>
QEMU and KVM support:
</p>
<ul>
<li>'i6300esb' - the recommended device,
emulating a PCI Intel 6300ESB </li>
<li>'ib700' - emulating an ISA iBase IB700 </li>
<li>'diag288' - emulating an S390 DIAG288 device
<span class="since">Since 1.2.17</span></li>
</ul>
</dd>
<dt>
<code>action</code>
</dt>
<dd>
<p>
The optional <code>action</code> attribute describes what
action to take when the watchdog expires. Valid values are
specific to the underlying hypervisor.
</p>
<p>
QEMU and KVM support:
</p>
<ul>
<li>'reset' - default, forcefully reset the guest</li>
<li>'shutdown' - gracefully shutdown the guest
(not recommended) </li>
<li>'poweroff' - forcefully power off the guest</li>
<li>'pause' - pause the guest</li>
<li>'none' - do nothing</li>
<li>'dump' - automatically dump the guest
<span class="since">Since 0.8.7</span></li>
<li>'inject-nmi' - inject a non-maskable interrupt
into the guest
<span class="since">Since 1.2.17</span></li>
</ul>
<p>
Note 1: the 'shutdown' action requires that the guest
is responsive to ACPI signals. In the sort of situations
where the watchdog has expired, guests are usually unable
to respond to ACPI signals. Therefore using 'shutdown'
is not recommended.
</p>
<p>
Note 2: the directory to save dump files can be configured
by <code>auto_dump_path</code> in file /etc/libvirt/qemu.conf.
</p>
</dd>
</dl>
<h4>
<a id="elementsMemBalloon">Memory balloon device</a>
<a class="headerlink" href="#elementsMemBalloon" title="Permalink to this headline">¶</a>
</h4>
<p>
A virtual memory balloon device is added to all Xen and KVM/QEMU
guests. It will be seen as <code>memballoon</code> element.
It will be automatically added when appropriate, so there is no
need to explicitly add this element in the guest XML unless a
specific PCI slot needs to be assigned.
<span class="since">Since 0.8.3, Xen, QEMU and KVM only</span>
Additionally, <span class="since">since 0.8.4</span>, if the
memballoon device needs to be explicitly disabled,
<code>model='none'</code> may be used.
</p>
<p>
Example: automatically added device with KVM
</p>
<pre>
...
<devices>
<memballoon model='virtio'/>
</devices>
...</pre>
<p>
Example: manually added device with static PCI slot 2 requested
</p>
<pre>
...
<devices>
<memballoon model='virtio'>
<address type='pci' domain='0x0000' bus='0x00' slot='0x02' function='0x0'/>
<stats period='10'/>
<driver iommu='on' ats='on'/>
</memballoon>
</devices>
</domain></pre>
<dl>
<dt>
<code>model</code>
</dt>
<dd>
<p>
The required <code>model</code> attribute specifies what type
of balloon device is provided. Valid values are specific to
the virtualization platform
</p>
<ul>
<li>'virtio' - default with QEMU/KVM</li>
<li>'xen' - default with Xen</li>
</ul>
</dd>
<dt>
<code>autodeflate</code>
</dt>
<dd>
<p>
The optional <code>autodeflate</code> attribute allows to
enable/disable (values "on"/"off", respectively) the ability of the
QEMU virtio memory balloon to release some memory at the last moment
before a guest's process get killed by Out of Memory killer.
<span class="since">Since 1.3.1, QEMU and KVM only</span>
</p>
</dd>
<dt>
<code>period</code>
</dt>
<dd>
<p>
The optional <code>period</code> allows the QEMU virtio memory balloon
driver to provide statistics through the <code>virsh dommemstat
[domain]</code> command. By default, collection is not enabled. In
order to enable, use the <code>virsh dommemstat [domain] --period
[number]</code> command or <code>virsh edit</code> command to add the
option to the XML definition. The <code>virsh dommemstat</code> will
accept the options <code>--live</code>, <code>--current</code>,
or <code>--config</code>. If an option is not provided, the change
for a running domain will only be made to the active guest. If the
QEMU driver is not at the right revision, the attempt to set the
period will fail. Large values (e.g. many years) might be ignored.
<span class="since">Since 1.1.1, requires QEMU 1.5</span>
</p>
</dd>
<dt>
<code>driver</code>
</dt>
<dd>
For model <code>virtio</code> memballoon,
<a href="#elementsVirtio">Virtio-specific options</a> can also be
set. (<span class="since">Since 3.5.0</span>)
</dd>
</dl>
<h4>
<a id="elementsRng">Random number generator device</a>
<a class="headerlink" href="#elementsRng" title="Permalink to this headline">¶</a>
</h4>
<p>
The virtual random number generator device allows the host to pass
through entropy to guest operating systems.
<span class="since">Since 1.0.3</span>
</p>
<p>
Example: usage of the RNG device:
</p>
<pre>
...
<devices>
<rng model='virtio'>
<rate period="2000" bytes="1234"/>
<backend model='random'>/dev/random</backend>
<!-- OR -->
<backend model='egd' type='udp'>
<source mode='bind' service='1234'/>
<source mode='connect' host='1.2.3.4' service='1234'/>
</backend>
</rng>
</devices>
...
</pre>
<dl>
<dt>
<code>model</code>
</dt>
<dd>
<p>
The required <code>model</code> attribute specifies what type
of RNG device is provided. Valid values are specific to
the virtualization platform:
</p>
<ul>
<li>'virtio' - supported by qemu and virtio-rng kernel module</li>
</ul>
</dd>
<dt>
<code>rate</code>
</dt>
<dd>
<p>
The optional <code>rate</code> element allows limiting the rate at
which entropy can be consumed from the source. The mandatory
attribute <code>bytes</code> specifies how many bytes are permitted
to be consumed per period. An optional <code>period</code> attribute
specifies the duration of a period in milliseconds; if omitted, the
period is taken as 1000 milliseconds (1 second).
<span class="since">Since 1.0.4</span>
</p>
</dd>
<dt>
<code>backend</code>
</dt>
<dd>
<p>
The <code>backend</code> element specifies the source of entropy
to be used for the domain. The source model is configured using the
<code>model</code> attribute. Supported source models are:
</p>
<dl>
<dt>
<code>random</code>
</dt>
<dd>
<p>
This backend type expects a non-blocking character device
as input. The file name is specified as contents of the
<code>backend</code> element. <span class="since">Since
1.3.4</span> any path is accepted. Before that
<code>/dev/random</code> and <code>/dev/hwrng</code> were
the only accepted paths. When no file name is specified,
the hypervisor default is used. For QEMU, the default is
<code>/dev/random</code>. However, the recommended source
of entropy is <code>/dev/urandom</code> (as it doesn't
have the limitations of <code>/dev/random</code>).
</p>
</dd>
<dt>
<code>egd</code>
</dt>
<dd>
<p>
This backend connects to a source using the EGD protocol.
The source is specified as a character device. Refer to
<a href="#elementsCharHostInterface">character device host interface</a>
for more information.
</p>
</dd>
</dl>
</dd>
<dt>
<code>driver</code>
</dt>
<dd>
The subelement <code>driver</code> can be used to tune the device:
<dl><dt>virtio options</dt><dd><a href="#elementsVirtio">Virtio-specific options</a> can also be
set. (<span class="since">Since 3.5.0</span>)
</dd></dl>
</dd>
</dl>
<h4>
<a id="elementsTpm">TPM device</a>
<a class="headerlink" href="#elementsTpm" title="Permalink to this headline">¶</a>
</h4>
<p>
The TPM device enables a QEMU guest to have access to TPM
functionality. The TPM device may either be a TPM 1.2 or
a TPM 2.0.
</p>
<p>
The TPM passthrough device type provides access to the host's TPM
for one QEMU guest. No other software may be using the TPM device,
typically /dev/tpm0, at the time the QEMU guest is started.
<span class="since">'passthrough' since 1.0.5</span>
</p>
<p>
Example: usage of the TPM passthrough device
</p>
<pre>
...
<devices>
<tpm model='tpm-tis'>
<backend type='passthrough'>
<device path='/dev/tpm0'/>
</backend>
</tpm>
</devices>
...
</pre>
<p>
The emulator device type gives access to a TPM emulator providing
TPM functionality for each VM. QEMU talks to it over a Unix socket. With
the emulator device type each guest gets its own private TPM.
<span class="since">'emulator' since 4.5.0</span>
</p>
<p>
Example: usage of the TPM Emulator
</p>
<pre>
...
<devices>
<tpm model='tpm-tis'>
<backend type='emulator' version='2.0'>
</backend>
</tpm>
</devices>
...
</pre>
<dl>
<dt>
<code>model</code>
</dt>
<dd>
<p>
The <code>model</code> attribute specifies what device
model QEMU provides to the guest. If no model name is provided,
<code>tpm-tis</code> will automatically be chosen.
<span class="since">Since 4.4.0</span>, another available choice
is the <code>tpm-crb</code>, which should only be used when the
backend device is a TPM 2.0.
</p>
</dd>
<dt>
<code>backend</code>
</dt>
<dd>
<p>
The <code>backend</code> element specifies the type of
TPM device. The following types are supported:
</p>
<dl>
<dt>
<code>passthrough</code>
</dt>
<dd>
<p>
Use the host's TPM device.
</p>
<p>
This backend type requires exclusive access to a TPM device on
the host. An example for such a device is /dev/tpm0. The fully
qualified file name is specified by path attribute of the
<code>source</code> element. If no file name is specified then
/dev/tpm0 is automatically used.
</p>
</dd>
</dl>
<dl>
<dt>
<code>emulator</code>
</dt>
<dd>
<p>
For this backend type the 'swtpm' TPM Emulator must be installed on the
host. Libvirt will automatically start an independent TPM emulator
for each QEMU guest requesting access to it.
</p>
</dd>
</dl>
</dd>
<dt>
<code>version</code>
</dt>
<dd>
<p>
The <code>version</code> attribute indicates the version
of the TPM. By default a TPM 1.2 is created. This attribute
only works with the <code>emulator</code> backend. The following
versions are supported:
</p>
<ul>
<li>'1.2' : creates a TPM 1.2</li>
<li>'2.0' : creates a TPM 2.0</li>
</ul>
</dd>
</dl>
<h4>
<a id="elementsNVRAM">NVRAM device</a>
<a class="headerlink" href="#elementsNVRAM" title="Permalink to this headline">¶</a>
</h4>
<p>
nvram device is always added to pSeries guest on PPC64, and its address
is allowed to be changed. Element <code>nvram</code> (only valid for
pSeries guest, <span class="since">since 1.0.5</span>) is provided to
enable the address setting.
</p>
<p>
Example: usage of NVRAM configuration
</p>
<pre>
...
<devices>
<nvram>
<address type='spapr-vio' reg='0x3000'/>
</nvram>
</devices>
...
</pre>
<dl>
<dt>
<code>spapr-vio</code>
</dt>
<dd>
<p>
VIO device address type, only valid for PPC64.
</p>
</dd>
<dt>
<code>reg</code>
</dt>
<dd>
<p>
Device address
</p>
</dd>
</dl>
<h4>
<a id="elementsPanic">panic device</a>
<a class="headerlink" href="#elementsPanic" title="Permalink to this headline">¶</a>
</h4>
<p>
panic device enables libvirt to receive panic notification from a QEMU
guest.
<span class="since">Since 1.2.1, QEMU and KVM only</span>
</p>
<p>
This feature is always enabled for:
</p>
<ul>
<li>pSeries guests, since it's implemented by the guest firmware</li>
<li>S390 guests, since it's an integral part of the S390 architecture</li>
</ul>
<p>
For the guest types listed above, libvirt automatically adds a
<code>panic</code> element to the domain XML.
</p>
<p>
Example: usage of panic configuration
</p>
<pre>
...
<devices>
<panic model='hyperv'/>
<panic model='isa'>
<address type='isa' iobase='0x505'/>
</panic>
</devices>
...
</pre>
<dl>
<dt>
<code>model</code>
</dt>
<dd>
<p>
The optional <code>model</code> attribute specifies what type
of panic device is provided. The panic model used when this attribute
is missing depends on the hypervisor and guest arch.
</p>
<ul>
<li>'isa' - for ISA pvpanic device</li>
<li>'pseries' - default and valid only for pSeries guests.</li>
<li>'hyperv' - for Hyper-V crash CPU feature.
<span class="since">Since 1.3.0, QEMU and KVM only</span></li>
<li>'s390' - default for S390 guests.
<span class="since">Since 1.3.5</span></li>
</ul>
</dd>
<dt>
<code>address</code>
</dt>
<dd>
<p>
address of panic. The default ioport is 0x505. Most users
don't need to specify an address, and doing so is forbidden
altogether for s390, pseries and hyperv models.
</p>
</dd>
</dl>
<h4>
<a id="elementsShmem">Shared memory device</a>
<a class="headerlink" href="#elementsShmem" title="Permalink to this headline">¶</a>
</h4>
<p>
A shared memory device allows to share a memory region between
different virtual machines and the host.
<span class="since">Since 1.2.10, QEMU and KVM only</span>
</p>
<pre>
...
<devices>
<shmem name='my_shmem0'>
<model type='ivshmem-plain'/>
<size unit='M'>4</size>
</shmem>
<shmem name='shmem_server'>
<model type='ivshmem-doorbell'/>
<size unit='M'>2</size>
<server path='/tmp/socket-shmem'/>
<msi vectors='32' ioeventfd='on'/>
</shmem>
</devices>
...
</pre>
<dl>
<dt>
<code>shmem</code>
</dt>
<dd>
The <code>shmem</code> element has one mandatory attribute,
<code>name</code> to identify the shared memory. This attribute cannot
be directory specific to <code>.</code> or <code>..</code> as well as
it cannot involve path separator <code>/</code>.
</dd>
<dt>
<code>model</code>
</dt>
<dd>
Attribute <code>type</code> of the optional element <code>model</code>
specifies the model of the underlying device providing the
<code>shmem</code> device. The models currently supported are
<code>ivshmem</code> (supports both server and server-less shmem, but is
deprecated by newer QEMU in favour of the -plain and -doorbell variants),
<code>ivshmem-plain</code> (only for server-less shmem) and
<code>ivshmem-doorbell</code> (only for shmem with the server).
</dd>
<dt>
<code>size</code>
</dt>
<dd>
The optional <code>size</code> element specifies the size of the shared
memory. This must be power of 2 and greater than or equal to 1 MiB.
</dd>
<dt>
<code>server</code>
</dt>
<dd>
The optional <code>server</code> element can be used to configure a server
socket the device is supposed to connect to. The optional
<code>path</code> attribute specifies the absolute path to the unix socket
and defaults to <code>/var/lib/libvirt/shmem/$shmem-$name-sock</code>.
</dd>
<dt>
<code>msi</code>
</dt>
<dd>
The optional <code>msi</code> element enables/disables (values "on"/"off",
respectively) MSI interrupts. This option can currently be used only
together with the <code>server</code> element. The <code>vectors</code>
attribute can be used to specify the number of interrupt
vectors. The <code>ioeventd</code> attribute enables/disables (values
"on"/"off", respectively) ioeventfd.
</dd>
</dl>
<h4>
<a id="elementsMemory">Memory devices</a>
<a class="headerlink" href="#elementsMemory" title="Permalink to this headline">¶</a>
</h4>
<p>
In addition to the initial memory assigned to the guest, memory devices
allow additional memory to be assigned to the guest in the form of
memory modules.
A memory device can be hot-plugged or hot-unplugged depending on the
guests' memory resource needs.
Some hypervisors may require NUMA configured for the guest.
</p>
<p>
Example: usage of the memory devices
</p>
<pre>
...
<devices>
<memory model='dimm' access='private' discard='yes'>
<target>
<size unit='KiB'>524287</size>
<node>0</node>
</target>
</memory>
<memory model='dimm'>
<source>
<pagesize unit='KiB'>4096</pagesize>
<nodemask>1-3</nodemask>
</source>
<target>
<size unit='KiB'>524287</size>
<node>1</node>
</target>
</memory>
<memory model='nvdimm'>
<source>
<path>/tmp/nvdimm</path>
<alignsize unit='KiB'>2048</alignsize>
</source>
<target>
<size unit='KiB'>524288</size>
<node>1</node>
<label>
<size unit='KiB'>128</size>
</label>
<readonly/>
</target>
</memory>
<memory model='nvdimm'>
<source>
<path>/dev/dax0.0</path>
<pmem/>
</source>
<target>
<size unit='KiB'>524288</size>
<node>1</node>
<label>
<size unit='KiB'>128</size>
</label>
</target>
</memory>
</devices>
...
</pre>
<dl>
<dt>
<code>model</code>
</dt>
<dd>
<p>
Provide <code>dimm</code> to add a virtual DIMM module to the guest.
<span class="since">Since 1.2.14</span>
Provide <code>nvdimm</code> model adds a Non-Volatile DIMM
module. <span class="since">Since 3.2.0</span>
</p>
</dd>
<dt>
<code>access</code>
</dt>
<dd>
<p>
An optional attribute <code>access</code>
(<span class="since">since 3.2.0</span>) that provides
capability to fine tune mapping of the memory on per
module basis. Values are the same as
<a href="#elementsMemoryBacking">Memory Backing</a>:
<code>shared</code> and <code>private</code>.
</p>
</dd>
<dt>
<code>discard</code>
</dt>
<dd>
<p>
An optional attribute <code>discard</code>
(<span class="since">since 4.4.0</span>) that provides
capability to fine tune discard of data on per module
basis. Accepted values are <code>yes</code> and
<code>no</code>. The feature is described here:
<a href="#elementsMemoryBacking">Memory Backing</a>.
This attribute is allowed only for
<code>model='dimm'</code>.
</p>
</dd>
<dt>
<code>source</code>
</dt>
<dd>
<p>
For model <code>dimm</code> this element is optional and allows to
fine tune the source of the memory used for the given memory device.
If the element is not provided defaults configured via
<code>numatune</code> are used. If <code>dimm</code> is provided,
then the following optional elements can be provided as well:
</p>
<dl>
<dt>
<code>pagesize</code>
</dt>
<dd>
<p>
This element can be used to override the default
host page size used for backing the memory device.
The configured value must correspond to a page size
supported by the host.
</p>
</dd>
<dt>
<code>nodemask</code>
</dt>
<dd>
<p>
This element can be used to override the default
set of NUMA nodes where the memory would be
allocated.
</p>
</dd>
</dl>
<p>
For model <code>nvdimm</code> this element is mandatory. The
mandatory child element <code>path</code> represents a path in
the host that backs the nvdimm module in the guest. The following
optional elements may be used:
</p>
<dl>
<dt>
<code>alignsize</code>
</dt>
<dd>
<p>
The <code>alignsize</code> element defines the page size
alignment used to mmap the address range for the backend
<code>path</code>. If not supplied the host page size is used.
For example, to mmap a real NVDIMM device a 2M-aligned page may
be required.
<span class="since">Since 5.0.0</span>
</p>
</dd>
<dt>
<code>pmem</code>
</dt>
<dd>
<p>
If persistent memory is supported and enabled by the hypervisor
in order to guarantee the persistence of writes to the vNVDIMM
backend, then use the <code>pmem</code> element in order to
utilize the feature.
<span class="since">Since 5.0.0</span>
</p>
</dd>
</dl>
</dd>
<dt>
<code>target</code>
</dt>
<dd>
<p>
The mandatory <code>target</code> element configures the placement and
sizing of the added memory from the perspective of the guest.
</p>
<p>
The mandatory <code>size</code> subelement configures the size of the
added memory as a scaled integer.
</p>
<p>
The <code>node</code> subelement configures the guest NUMA node to
attach the memory to. The element shall be used only if the guest has
NUMA nodes configured.
</p>
<p>
The following optional elements may be used:
</p>
<dl>
<dt>
<code>label</code>
</dt>
<dd>
<p>
For NVDIMM type devices one can optionally use
<code>label</code> and its subelement <code>size</code>
to configure the size of namespaces label storage
within the NVDIMM module. The <code>size</code> element
has usual meaning described
<a href="#elementsMemoryAllocation">here</a>.
For QEMU domains the following restrictions apply:
</p>
<ol>
<li>the minimum label size is 128KiB,</li>
<li>the remaining size (total-size - label-size) will be aligned
to 4KiB as default.</li>
</ol>
</dd>
<dt>
<code>readonly</code>
</dt>
<dd>
<p>
The <code>readonly</code> element is used to mark the vNVDIMM
as read-only. Only the real NVDIMM device backend can guarantee
the guest write persistence, so other backend types should use
the <code>readonly</code> element.
<span class="since">Since 5.0.0</span>
</p>
</dd>
</dl>
</dd>
</dl>
<h4>
<a id="elementsIommu">IOMMU devices</a>
<a class="headerlink" href="#elementsIommu" title="Permalink to this headline">¶</a>
</h4>
<p>
The <code>iommu</code> element can be used to add an IOMMU device.
<span class="since">Since 2.1.0</span>
</p>
<p>
Example:
</p>
<pre>
...
<devices>
<iommu model='intel'>
<driver intremap='on'/>
</iommu>
</devices>
...
</pre>
<dl>
<dt>
<code>model</code>
</dt>
<dd>
<p>
Currently only the <code>intel</code> model is supported.
</p>
</dd>
<dt>
<code>driver</code>
</dt>
<dd>
<p>
The <code>driver</code> subelement can be used to configure
additional options:
</p>
<dl>
<dt>
<code>intremap</code>
</dt>
<dd>
<p>
The <code>intremap</code> attribute with possible values
<code>on</code> and <code>off</code> can be used to
turn on interrupt remapping, a part of the VT-d functionality.
Currently this requires split I/O APIC
(<code><ioapic driver='qemu'/></code>).
<span class="since">Since 3.4.0</span> (QEMU/KVM only)
</p>
</dd>
<dt>
<code>caching_mode</code>
</dt>
<dd>
<p>
The <code>caching_mode</code> attribute with possible values
<code>on</code> and <code>off</code> can be used to
turn on the VT-d caching mode (useful for assigned devices).
<span class="since">Since 3.4.0</span> (QEMU/KVM only)
</p>
</dd>
<dt>
<code>eim</code>
</dt>
<dd>
<p>
The <code>eim</code> attribute (with possible values
<code>on</code> and <code>off</code>) can be used to
configure Extended Interrupt Mode. A q35 domain with
split I/O APIC (as described in
<a href="#elementsFeatures">hypervisor features</a>),
and both interrupt remapping and EIM turned on for
the IOMMU, will be able to use more than 255 vCPUs.
<span class="since">Since 3.4.0</span> (QEMU/KVM only)
</p>
</dd>
<dt>
<code>iotlb</code>
</dt>
<dd>
<p>
The <code>iotlb</code> attribute with possible values
<code>on</code> and <code>off</code> can be used to
turn on the IOTLB used to cache address translation
requests from devices.
<span class="since">Since 3.5.0</span> (QEMU/KVM only)
</p>
</dd>
</dl>
</dd>
</dl>
<h3>
<a id="vsock">Vsock</a>
<a class="headerlink" href="#vsock" title="Permalink to this headline">¶</a>
</h3>
<p>A vsock host/guest interface. The <code>model</code> attribute
defaults to <code>virtio</code>.
The optional attribute <code>address</code> of the <code>cid</code>
element specifies the CID assigned to the guest. If the attribute
<code>auto</code> is set to <code>yes</code>, libvirt
will assign a free CID automatically on domain startup.
<span class="since">Since 4.4.0</span></p>
<pre>
...
<devices>
<vsock model='virtio'>
<cid auto='no' address='3'/>
</vsock>
</devices>
...</pre>
<h3>
<a id="seclabel">Security label</a>
<a class="headerlink" href="#seclabel" title="Permalink to this headline">¶</a>
</h3>
<p>
The <code>seclabel</code> element allows control over the
operation of the security drivers. There are three basic
modes of operation, 'dynamic' where libvirt automatically
generates a unique security label, 'static' where the
application/administrator chooses the labels, or 'none'
where confinement is disabled. With dynamic
label generation, libvirt will always automatically
relabel any resources associated with the virtual machine.
With static label assignment, by default, the administrator
or application must ensure labels are set correctly on any
resources, however, automatic relabeling can be enabled
if desired. <span class="since">'dynamic' since 0.6.1, 'static'
since 0.6.2, and 'none' since 0.9.10.</span>
</p>
<p>
If more than one security driver is used by libvirt, multiple
<code>seclabel</code> tags can be used, one for each driver and
the security driver referenced by each tag can be defined using
the attribute <code>model</code>
</p>
<p>
Valid input XML configurations for the top-level security label
are:
</p>
<pre>
<seclabel type='dynamic' model='selinux'/>
<seclabel type='dynamic' model='selinux'>
<baselabel>system_u:system_r:my_svirt_t:s0</baselabel>
</seclabel>
<seclabel type='static' model='selinux' relabel='no'>
<label>system_u:system_r:svirt_t:s0:c392,c662</label>
</seclabel>
<seclabel type='static' model='selinux' relabel='yes'>
<label>system_u:system_r:svirt_t:s0:c392,c662</label>
</seclabel>
<seclabel type='none'/>
</pre>
<p>
If no 'type' attribute is provided in the input XML, then
the security driver default setting will be used, which
may be either 'none' or 'dynamic'. If a 'baselabel' is set
but no 'type' is set, then the type is presumed to be 'dynamic'
</p>
<p>
When viewing the XML for a running guest with automatic
resource relabeling active, an additional XML element,
<code>imagelabel</code>, will be included. This is an
output-only element, so will be ignored in user supplied
XML documents
</p>
<dl>
<dt>
<code>type</code>
</dt>
<dd>Either <code>static</code>, <code>dynamic</code> or <code>none</code>
to determine whether libvirt automatically generates a unique security
label or not.
</dd>
<dt>
<code>model</code>
</dt>
<dd>A valid security model name, matching the currently
activated security model
</dd>
<dt>
<code>relabel</code>
</dt>
<dd>Either <code>yes</code> or <code>no</code>. This must always
be <code>yes</code> if dynamic label assignment is used. With
static label assignment it will default to <code>no</code>.
</dd>
<dt>
<code>label</code>
</dt>
<dd>If static labelling is used, this must specify the full
security label to assign to the virtual domain. The format
of the content depends on the security driver in use:
<ul><li>SELinux: a SELinux context.</li><li>AppArmor: an AppArmor profile.</li><li>
DAC: owner and group separated by colon. They can be
defined both as user/group names or uid/gid. The driver will first
try to parse these values as names, but a leading plus sign can
used to force the driver to parse them as uid or gid.
</li></ul>
</dd>
<dt>
<code>baselabel</code>
</dt>
<dd>If dynamic labelling is used, this can optionally be
used to specify the base security label that will be used to generate
the actual label. The format of the content depends on the security
driver in use.
The SELinux driver uses only the <code>type</code> field of the
baselabel in the generated label. Other fields are inherited from
the parent process when using SELinux baselabels.
(The example above demonstrates the use of <code>my_svirt_t</code>
as the value for the <code>type</code> field.)
</dd>
<dt>
<code>imagelabel</code>
</dt>
<dd>This is an output only element, which shows the
security label used on resources associated with the virtual domain.
The format of the content depends on the security driver in use
</dd>
</dl>
<p>When relabeling is in effect, it is also possible to fine-tune
the labeling done for specific source file names, by either
disabling the labeling (useful if the file lives on NFS or other
file system that lacks security labeling) or requesting an
alternate label (useful when a management application creates a
special label to allow sharing of some, but not all, resources
between domains), <span class="since">since 0.9.9</span>. When
a <code>seclabel</code> element is attached to a specific path
rather than the top-level domain assignment, only the
attribute <code>relabel</code> or the
sub-element <code>label</code> are supported. Additionally,
<span class="since">since 1.1.2</span>, an output-only
element <code>labelskip</code> will be present for active
domains on disks where labeling was skipped due to the image
being on a file system that lacks security labeling.
</p>
<h3>
<a id="keywrap">Key Wrap</a>
<a class="headerlink" href="#keywrap" title="Permalink to this headline">¶</a>
</h3>
<p>The content of the optional <code>keywrap</code> element specifies
whether the guest will be allowed to perform the S390 cryptographic key
management operations. A clear key can be protected by encrypting it
under a unique wrapping key that is generated for each guest VM running
on the host. Two variations of wrapping keys are generated: one version
for encrypting protected keys using the DEA/TDEA algorithm, and another
version for keys encrypted using the AES algorithm. If a
<code>keywrap</code> element is not included, the guest will be granted
access to both AES and DEA/TDEA key wrapping by default.</p>
<pre>
<domain>
...
<keywrap>
<cipher name='aes' state='off'/>
</keywrap>
...
</domain>
</pre>
<p>
At least one <code>cipher</code> element must be nested within the
<code>keywrap</code> element.
</p>
<dl>
<dt>
<code>cipher</code>
</dt>
<dd>The <code>name</code> attribute identifies the algorithm
for encrypting a protected key. The values supported for this attribute
are <code>aes</code> for encryption under the AES wrapping key, or
<code>dea</code> for encryption under the DEA/TDEA wrapping key. The
<code>state</code> attribute indicates whether the cryptographic key
management operations should be turned on for the specified encryption
algorithm. The value can be set to <code>on</code> or <code>off</code>.
</dd>
</dl>
<p>Note: DEA/TDEA is synonymous with DES/TDES.</p>
<h3>
<a id="sev">Launch Security</a>
<a class="headerlink" href="#sev" title="Permalink to this headline">¶</a>
</h3>
<p>
The contents of the <code><launchSecurity type='sev'></code> element
is used to provide the guest owners input used for creating an encrypted
VM using the AMD SEV feature (Secure Encrypted Virtualization).
SEV is an extension to the AMD-V architecture which supports running
encrypted virtual machine (VMs) under the control of KVM. Encrypted
VMs have their pages (code and data) secured such that only the guest
itself has access to the unencrypted version. Each encrypted VM is
associated with a unique encryption key; if its data is accessed to a
different entity using a different key the encrypted guests data will
be incorrectly decrypted, leading to unintelligible data.
For more information see various input parameters and its format see the SEV API spec
<a href="https://support.amd.com/TechDocs/55766_SEV-KM%20API_Specification.pdf"> https://support.amd.com/TechDocs/55766_SEV-KM%20API_Specification.pdf </a>
<span class="since">Since 4.4.0</span>
</p>
<pre>
<domain>
...
<launchSecurity type='sev'>
<policy>0x0001</policy>
<cbitpos>47</cbitpos>
<reducedPhysBits>1</reducedPhysBits>
<dhCert>RBBBSDDD=FDDCCCDDDG</dhCert>
<session>AAACCCDD=FFFCCCDSDS</session>
</launchSecurity>
...
</domain>
</pre>
<dl>
<dt>
<code>cbitpos</code>
</dt>
<dd>The required <code>cbitpos</code> element provides the C-bit (aka encryption bit)
location in guest page table entry. The value of <code>cbitpos</code> is
hypervisor dependent and can be obtained through the <code>sev</code> element
from the domain capabilities.
</dd>
<dt>
<code>reducedPhysBits</code>
</dt>
<dd>The required <code>reducedPhysBits</code> element provides the physical
address bit reducation. Similar to <code>cbitpos</code> the value of <code>
reduced-phys-bit</code> is hypervisor dependent and can be obtained
through the <code>sev</code> element from the domain capabilities.
</dd>
<dt>
<code>policy</code>
</dt>
<dd>The required <code>policy</code> element provides the guest policy
which must be maintained by the SEV firmware. This policy is enforced by
the firmware and restricts what configuration and operational commands
can be performed on this guest by the hypervisor. The guest policy
provided during guest launch is bound to the guest and cannot be changed
throughout the lifetime of the guest. The policy is also transmitted
during snapshot and migration flows and enforced on the destination platform.
The guest policy is a 4 unsigned byte with the fields shown in Table:
<table class="top_table"><tr><th> Bit(s) </th><th> Description </th></tr><tr><td> 0 </td><td> Debugging of the guest is disallowed when set </td></tr><tr><td> 1 </td><td> Sharing keys with other guests is disallowed when set </td></tr><tr><td> 2 </td><td> SEV-ES is required when set</td></tr><tr><td> 3 </td><td> Sending the guest to another platform is disallowed when set</td></tr><tr><td> 4 </td><td> The guest must not be transmitted to another platform that is
not in the domain when set. </td></tr><tr><td> 5 </td><td> The guest must not be transmitted to another platform that is
not SEV capable when set. </td></tr><tr><td> 6:15 </td><td> reserved </td></tr><tr><td> 16:32 </td><td> The guest must not be transmitted to another platform with a
lower firmware version. </td></tr></table>
</dd>
<dt>
<code>dhCert</code>
</dt>
<dd>The optional <code>dhCert</code> element provides the guest owners
base64 encoded Diffie-Hellman (DH) key. The key is used to negotiate a
master secret key between the SEV firmware and guest owner. This master
secret key is then used to establish a trusted channel between SEV
firmware and guest owner.
</dd>
<dt>
<code>session</code>
</dt>
<dd>The optional <code>session</code> element provides the guest owners
base64 encoded session blob defined in the SEV API spec.
See SEV spec LAUNCH_START section for the session blob format.
</dd>
</dl>
<h2>
<a id="examples">Example configs</a>
<a class="headerlink" href="#examples" title="Permalink to this headline">¶</a>
</h2>
<p>
Example configurations for each driver are provide on the
driver specific pages listed below
</p>
<ul>
<li>
<a href="drvxen.html#xmlconfig">Xen examples</a>
</li>
<li>
<a href="drvqemu.html#xmlconfig">QEMU/KVM examples</a>
</li>
</ul>
</div>
</div>
<div id="nav">
<div id="home">
<a href="index.html">Home</a>
</div>
<div id="jumplinks">
<ul>
<li>
<a href="downloads.html">Download</a>
</li>
<li>
<a href="contribute.html">Contribute</a>
</li>
<li>
<a href="docs.html">Docs</a>
</li>
</ul>
</div>
<div id="search">
<form action="search.php" enctype="application/x-www-form-urlencoded" method="get">
<div>
<input name="query" type="text" size="12" value=""/>
<input name="submit" type="submit" value="Go"/>
</div>
</form>
</div>
</div>
<div id="footer">
<div id="contact">
<h3>Contact</h3>
<ul>
<li>
<a href="contact.html#email">email</a>
</li>
<li>
<a href="contact.html#irc">irc</a>
</li>
</ul>
</div>
<div id="community">
<h3>Community</h3>
<ul>
<li>
<a href="https://twitter.com/hashtag/libvirt">twitter</a>
</li>
<li>
<a href="https://plus.google.com/communities/109522598353007505282">google+</a>
</li>
<li>
<a href="http://stackoverflow.com/questions/tagged/libvirt">stackoverflow</a>
</li>
<li>
<a href="http://serverfault.com/questions/tagged/libvirt">serverfault</a>
</li>
</ul>
</div>
<div id="conduct">
Participants in the libvirt project agree to abide by <a href="governance.html#codeofconduct">the project code of conduct</a></div>
<br class="clear"/>
</div>
</body>
</html>
|