1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272
|
.. SPDX-License-Identifier: GPL-2.0
===============================================================
Intel(R) Dynamic Platform and Thermal Framework Sysfs Interface
===============================================================
:Copyright: © 2022 Intel Corporation
:Author: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Introduction
------------
Intel(R) Dynamic Platform and Thermal Framework (DPTF) is a platform
level hardware/software solution for power and thermal management.
As a container for multiple power/thermal technologies, DPTF provides
a coordinated approach for different policies to effect the hardware
state of a system.
Since it is a platform level framework, this has several components.
Some parts of the technology is implemented in the firmware and uses
ACPI and PCI devices to expose various features for monitoring and
control. Linux has a set of kernel drivers exposing hardware interface
to user space. This allows user space thermal solutions like
"Linux Thermal Daemon" to read platform specific thermal and power
tables to deliver adequate performance while keeping the system under
thermal limits.
DPTF ACPI Drivers interface
----------------------------
:file:`/sys/bus/platform/devices/<N>/uuids`, where <N>
=INT3400|INTC1040|INTC1041|INTC10A0
``available_uuids`` (RO)
A set of UUIDs strings presenting available policies
which should be notified to the firmware when the
user space can support those policies.
UUID strings:
"42A441D6-AE6A-462b-A84B-4A8CE79027D3" : Passive 1
"3A95C389-E4B8-4629-A526-C52C88626BAE" : Active
"97C68AE7-15FA-499c-B8C9-5DA81D606E0A" : Critical
"63BE270F-1C11-48FD-A6F7-3AF253FF3E2D" : Adaptive performance
"5349962F-71E6-431D-9AE8-0A635B710AEE" : Emergency call
"9E04115A-AE87-4D1C-9500-0F3E340BFE75" : Passive 2
"F5A35014-C209-46A4-993A-EB56DE7530A1" : Power Boss
"6ED722A7-9240-48A5-B479-31EEF723D7CF" : Virtual Sensor
"16CAF1B7-DD38-40ED-B1C1-1B8A1913D531" : Cooling mode
"BE84BABF-C4D4-403D-B495-3128FD44dAC1" : HDC
``current_uuid`` (RW)
User space can write strings from available UUIDs, one at a
time.
:file:`/sys/bus/platform/devices/<N>/`, where <N>
=INT3400|INTC1040|INTC1041|INTC10A0
``imok`` (WO)
User space daemon write 1 to respond to firmware event
for sending keep alive notification. User space receives
THERMAL_EVENT_KEEP_ALIVE kobject uevent notification when
firmware calls for user space to respond with imok ACPI
method.
``odvp*`` (RO)
Firmware thermal status variable values. Thermal tables
calls for different processing based on these variable
values.
``data_vault`` (RO)
Binary thermal table. Refer to
https:/github.com/intel/thermal_daemon for decoding
thermal table.
ACPI Thermal Relationship table interface
------------------------------------------
:file:`/dev/acpi_thermal_rel`
This device provides IOCTL interface to read standard ACPI
thermal relationship tables via ACPI methods _TRT and _ART.
These IOCTLs are defined in
drivers/thermal/intel/int340x_thermal/acpi_thermal_rel.h
IOCTLs:
ACPI_THERMAL_GET_TRT_LEN: Get length of TRT table
ACPI_THERMAL_GET_ART_LEN: Get length of ART table
ACPI_THERMAL_GET_TRT_COUNT: Number of records in TRT table
ACPI_THERMAL_GET_ART_COUNT: Number of records in ART table
ACPI_THERMAL_GET_TRT: Read binary TRT table, length to read is
provided via argument to ioctl().
ACPI_THERMAL_GET_ART: Read binary ART table, length to read is
provided via argument to ioctl().
DPTF ACPI Sensor drivers
-------------------------
DPTF Sensor drivers are presented as standard thermal sysfs thermal_zone.
DPTF ACPI Cooling drivers
--------------------------
DPTF cooling drivers are presented as standard thermal sysfs cooling_device.
DPTF Processor thermal PCI Driver interface
--------------------------------------------
:file:`/sys/bus/pci/devices/0000\:00\:04.0/power_limits/`
Refer to Documentation/power/powercap/powercap.rst for powercap
ABI.
``power_limit_0_max_uw`` (RO)
Maximum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
``power_limit_0_step_uw`` (RO)
Power limit increment/decrements for Intel RAPL constraint 0 power limit
``power_limit_0_min_uw`` (RO)
Minimum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
``power_limit_0_tmin_us`` (RO)
Minimum powercap sysfs constraint_0_time_window_us for Intel RAPL
``power_limit_0_tmax_us`` (RO)
Maximum powercap sysfs constraint_0_time_window_us for Intel RAPL
``power_limit_1_max_uw`` (RO)
Maximum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
``power_limit_1_step_uw`` (RO)
Power limit increment/decrements for Intel RAPL constraint 1 power limit
``power_limit_1_min_uw`` (RO)
Minimum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
``power_limit_1_tmin_us`` (RO)
Minimum powercap sysfs constraint_1_time_window_us for Intel RAPL
``power_limit_1_tmax_us`` (RO)
Maximum powercap sysfs constraint_1_time_window_us for Intel RAPL
:file:`/sys/bus/pci/devices/0000\:00\:04.0/`
``tcc_offset_degree_celsius`` (RW)
TCC offset from the critical temperature where hardware will throttle
CPU.
:file:`/sys/bus/pci/devices/0000\:00\:04.0/workload_request`
``workload_available_types`` (RO)
Available workload types. User space can specify one of the workload type
it is currently executing via workload_type. For example: idle, bursty,
sustained etc.
``workload_type`` (RW)
User space can specify any one of the available workload type using
this interface.
DPTF Processor thermal RFIM interface
--------------------------------------------
RFIM interface allows adjustment of FIVR (Fully Integrated Voltage Regulator)
and DDR (Double Data Rate)frequencies to avoid RF interference with WiFi and 5G.
Switching voltage regulators (VR) generate radiated EMI or RFI at the
fundamental frequency and its harmonics. Some harmonics may interfere
with very sensitive wireless receivers such as Wi-Fi and cellular that
are integrated into host systems like notebook PCs. One of mitigation
methods is requesting SOC integrated VR (IVR) switching frequency to a
small % and shift away the switching noise harmonic interference from
radio channels. OEM or ODMs can use the driver to control SOC IVR
operation within the range where it does not impact IVR performance.
DRAM devices of DDR IO interface and their power plane can generate EMI
at the data rates. Similar to IVR control mechanism, Intel offers a
mechanism by which DDR data rates can be changed if several conditions
are met: there is strong RFI interference because of DDR; CPU power
management has no other restriction in changing DDR data rates;
PC ODMs enable this feature (real time DDR RFI Mitigation referred to as
DDR-RFIM) for Wi-Fi from BIOS.
FIVR attributes
:file:`/sys/bus/pci/devices/0000\:00\:04.0/fivr/`
``vco_ref_code_lo`` (RW)
The VCO reference code is an 11-bit field and controls the FIVR
switching frequency. This is the 3-bit LSB field.
``vco_ref_code_hi`` (RW)
The VCO reference code is an 11-bit field and controls the FIVR
switching frequency. This is the 8-bit MSB field.
``spread_spectrum_pct`` (RW)
Set the FIVR spread spectrum clocking percentage
``spread_spectrum_clk_enable`` (RW)
Enable/disable of the FIVR spread spectrum clocking feature
``rfi_vco_ref_code`` (RW)
This field is a read only status register which reflects the
current FIVR switching frequency
``fivr_fffc_rev`` (RW)
This field indicated the revision of the FIVR HW.
DVFS attributes
:file:`/sys/bus/pci/devices/0000\:00\:04.0/dvfs/`
``rfi_restriction_run_busy`` (RW)
Request the restriction of specific DDR data rate and set this
value 1. Self reset to 0 after operation.
``rfi_restriction_err_code`` (RW)
0 :Request is accepted, 1:Feature disabled,
2: the request restricts more points than it is allowed
``rfi_restriction_data_rate_Delta`` (RW)
Restricted DDR data rate for RFI protection: Lower Limit
``rfi_restriction_data_rate_Base`` (RW)
Restricted DDR data rate for RFI protection: Upper Limit
``ddr_data_rate_point_0`` (RO)
DDR data rate selection 1st point
``ddr_data_rate_point_1`` (RO)
DDR data rate selection 2nd point
``ddr_data_rate_point_2`` (RO)
DDR data rate selection 3rd point
``ddr_data_rate_point_3`` (RO)
DDR data rate selection 4th point
``rfi_disable (RW)``
Disable DDR rate change feature
DPTF Power supply and Battery Interface
----------------------------------------
Refer to Documentation/ABI/testing/sysfs-platform-dptf
DPTF Fan Control
----------------------------------------
Refer to Documentation/admin-guide/acpi/fan_performance_states.rst
|