File: sysfs-bus-iio-adc-ad-sigma-delta

package info (click to toggle)
linux 6.16.9-1
  • links: PTS, VCS
  • area: main
  • in suites: forky, sid
  • size: 1,724,628 kB
  • sloc: ansic: 26,562,645; asm: 271,329; sh: 144,039; python: 72,469; makefile: 57,135; perl: 36,821; xml: 19,553; cpp: 5,820; yacc: 4,915; lex: 2,955; awk: 1,667; sed: 28; ruby: 25
file content (23 lines) | stat: -rw-r--r-- 981 bytes parent folder | download | duplicates (11)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
What:		/sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration
KernelVersion: 5.5
Contact:	linux-iio@vger.kernel.org
Description:
		This attribute, if available, initiates the system calibration procedure. This is done on a
		single channel at a time. Write '1' to start the calibration.

What:		/sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration_mode_available
KernelVersion: 5.5
Contact:	linux-iio@vger.kernel.org
Description:
		This attribute, if available, returns a list with the possible calibration modes.
		There are two available options:
		"zero_scale" - calibrate to zero scale
		"full_scale" - calibrate to full scale

What:		/sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration_mode
KernelVersion: 5.5
Contact:	linux-iio@vger.kernel.org
Description:
		This attribute, if available, sets up the calibration mode used in the system calibration
		procedure. Reading returns the current calibration mode.
		Writing sets the system calibration mode.