1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279
|
.TH TS2PHC 8 "February 2023" "linuxptp"
.SH NAME
ts2phc - Synchronizes one or more PTP Hardware Clocks using external time stamps.
.SH SYNOPSIS
.B ts2phc
[
.B \-hmqv
] [
.BI \-c " device|name"
] [
.BI \-f " config"
] [
.BI \-l " print-level"
] [
.BI \-s " device|name"
] [
.I long-options
]
.I .\|.\|.
.SH DESCRIPTION
.B ts2phc
synchronizes PTP Hardware Clocks (PHC) to external time stamp signals.
A single source may be used to distribute time to one or more PHC devices.
.SH OPTIONS
.TP
.BI \-a
Adjust the direction of synchronization automatically. The program determines
which PHC should the reference clock for time distribution and which should
be the destinations by querying the port states from the running instance of
.B ptp4l.
Note that using this option, the PPS signal distribution hierarchy still
remains fixed as per the configuration file. This implies that using this
option, a PPS source of the PHC kind may become a target clock, and a PPS sink
may become a reference clock. Other, non-PHC types of PPS sources (generic,
NMEA) cannot become target clocks. Clocks which are not part of
.B ptp4l's
list of ports are not synchronized. This option is useful when the
.B boundary_clock_jbod
option of ptp4l is also enabled.
.TP
.BI \-c " device|name"
Specifies a PHC to be synchronized.
The clock may be identified by its character device (like /dev/ptp0)
or its associated network interface (like eth0).
This option may be given multiple times.
.TP
.BI \-f " config"
Read configuration from the specified file.
No configuration file is read by default.
.TP
.BI \-h
Displays the command line help summary.
.TP
.BI \-l " print-level"
Sets the maximum syslog level of messages which should be printed or
sent to the system logger. The default is 6 (LOG_INFO).
.TP
.B \-m
Prints log messages to the standard output.
.TP
.B \-q
Prevents sending log messages to the system logger.
.TP
.BI \-s " device|name"
Specifies the source of the Time of Day (ToD) data.
Use the key word "generic" for an external 1-PPS without ToD information.
When using a PHC as the time source, the clock may be identified by its character
device (like /dev/ptp0) or its associated network interface (like
eth0).
Use the key word "nmea" for an external 1-PPS from a GPS providing ToD
information via the RMC NMEA sentence.
.TP
.B \-v
Prints the software version and exits.
.SH LONG OPTIONS
Each and every configuration file option (see below) may also appear
as a "long" style command line argument. For example, the use_syslog
option may be set using either of these two forms.
.RS
\f(CW\-\-use_syslog 1 \-\-use_syslog=1\fP
.RE
Option values given on the command line override values in the global
section of the configuration file.
.SH CONFIGURATION FILE
The configuration file is divided into sections. Each section starts with a
line containing its name enclosed in brackets and it follows with settings.
Each setting is placed on a separate line, it contains the name of the
option and the value separated by whitespace characters. Empty lines and lines
starting with # are ignored.
There are two different section types.
.TP
.B 1.
The global section (indicated as
.BR [global] )
sets the program options and the default time sink options. Other
sections are clock specific sections, and they override the default
options.
.TP
.B 2.
Time sink sections give the name of the configured PHC (e.g.
.BR [eth0] ).
Time sinks specified in the configuration file need not be specified
with the
.B \-c
command line option.
.SH GLOBAL OPTIONS
.TP
.B first_step_threshold
The maximum offset, specified in seconds, that the servo will correct by
changing the clock frequency (phase when using nullf servo) instead of stepping
the clock. This is only applied on the first update. When set to 0.0, the servo
will not step the clock on start.
The default is 0.00002 (20 microseconds).
.TP
.B free_running
When set to 1, no PHC will be adjusted.
This option can be useful in test scenarios, for example to determine
how well synchronized a group of local clocks are to each other.
The default is 0 (adjust the clocks).
.TP
.B leapfile
The path to the current leap seconds definition file. In a Debian
system this file is provided by the tzdata package and can be found at
/usr/share/zoneinfo/leap-seconds.list. If a leapfile is configured it
will be reloaded if modified. The default is an empty string, which
causes the program to use a hard coded table that reflects the known
leap seconds on the date of the software's release.
.TP
.B logging_level
The maximum logging level of messages which should be printed.
The default is 6 (LOG_INFO).
.TP
.B max_frequency
The maximum allowed frequency adjustment of the clock in parts per
billion. This is an additional limit to the maximum allowed by the
hardware. When set to 0, the hardware limit will be used.
The default is 900000000 (90%).
.TP
.B message_tag
The tag which is added to all messages printed to the standard output
or system log. If the tag contains the string "{level}", it will be replaced
with the log level of the message as a number. The default is an empty string
(which cannot be set in the configuration file as the option requires an
argument).
.TP
.B step_threshold
The maximum offset, specified in seconds, that the servo will correct
by changing the clock frequency instead of stepping the clock. When
set to 0.0, the servo will never step the clock except on start.
The default is 0.0.
.TP
.B ts2phc.nmea_remote_host, ts2phc.nmea_remote_port
Specifies the remote host providing ToD information when using the
"nmea" PPS signal source. Note that if these two options are both
specified, then the given remote connection will be used in preference
to the configured serial port.
These options default to the empty string, that is, not specified.
.TP
.B ts2phc.nmea_serialport, ts2phc.nmea_baudrate
Specifies the serial port and baudrate in bps for character device
providing ToD information when using the "nmea" PPS signal source. Note
that if the options, ts2phc.nmea_remote_host and
ts2phc.nmea_remote_port, are both specified, then the given remote
connection will be used in preference to the configured serial port.
The default serial port is "/dev/ttyS0".
The default baudrate is 9600 bps.
.TP
.B ts2phc.perout_phase
Configures the offset between the beginning of the second and the PPS
source's rising edge. Available only for the PHC kind of PPS source. The supported
range is 0 to 999999999 nanoseconds. The default is 0 nanoseconds, but
leaving this option unspecified will not transmit the phase to the kernel,
instead PPS will be requested to start at an absolute time equal to the
nearest 2nd full second since the start of the program. This should yield
the same effect, but may not work with drivers that do not support
starting periodic output at an absolute time.
.TP
.B ts2phc.pulsewidth
The pulse width of the external PPS signal in nanoseconds.
When 'ts2phc.extts_polarity' is "both", the given pulse width is used
to detect and discard the time stamp of the unwanted edge. In case the PPS
source is of the PHC kind, an attempt is made to request the kernel to actually
emit using this pulse width. If this fails, it is assumed that the specified
pulse width is correct, and the value is used in the edge rejection algorithm.
The supported range is 1000000 to 990000000 nanoseconds.
The default is 500000000 nanoseconds.
.TP
.B ts2phc.tod_source
Specifies the source of Time of Day (ToD) data.
Use the key word "generic" for an external 1-PPS without ToD information.
When using a PHC as the time source, the clock may be identified by its character
device (like /dev/ptp0) or its associated network interface (like
eth0).
Use the key word "nmea" for an external 1-PPS from a GPS providing ToD
information via the RMC NMEA sentence.
The default is "generic"
.TP
.B use_syslog
Print messages to the system log if enabled. The default is 1 (enabled).
.TP
.B verbose
Print messages to the standard output if enabled. The default is 0 (disabled).
.SH TIME SINK OPTIONS
.TP
.B ts2phc.channel
The external time stamping or periodic output channel to be used.
Some PHC devices feature programmable pins and one or more time
stamping channels. This option allows selecting a particular channel
to be used. When using a PHC device as the PPS source, this option
selects the periodic output channel.
The default is channel 0.
.TP
.B ts2phc.extts_correction
The value, in nanoseconds, to be added to each PPS time stamp.
The default is 0 (no correction).
.TP
.B ts2phc.extts_polarity
The polarity of the external PPS signal, either "rising" or "falling".
Some PHC devices always time stamp both edges. Setting this option to
"both" will allow the ts2phc program to work with such devices by
detecting and ignoring the unwanted edge. In this case be sure to
set 'ts2phc.pulsewidth' to the correct value.
The default is "rising".
.TP
.B ts2phc.master
Setting this option to 1 configures the given PHC device as the source
of the PPS signal.
The default is 0 for the time sink role.
.TP
.B ts2phc.pin_index
The pin index to be used.
Some PHC devices feature programmable pins, and this option allows
configuration of a particular pin for the external time stamping or
periodic output function.
The default is pin index 0.
.SH WARNING
Be cautious when sharing the same configuration file between ptp4l,
phc2sys, and ts2phc. Keep in mind that values specified in the
configuration file take precedence over the default values. If an
option which is common to the other programs is set in the
configuration file, then the value will be applied to all the programs
using the file, and this might not be what is expected.
It is recommended to use separate configuration files for ptp4l,
phc2sys, and ts2phc in order to avoid any unexpected behavior.
.SH SEE ALSO
.BR phc2sys (8)
.BR ptp4l (8)
|