1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213
|
<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
<head>
<meta name="generator" content="HTML Tidy, see www.w3.org">
<title>Normal Termination</title>
<meta name="GENERATOR" content=
"Modular DocBook HTML Stylesheet Version 1.71 ">
<link rel="HOME" title=" LPRng-HOWTO" href="index.htm">
<link rel="UP" title="Job Processing" href="jobsteps.htm">
<link rel="PREVIOUS" title="Printing Banner At End of Job "
href="x7309.htm">
<link rel="NEXT" title="Abnormal Termination " href=
"abnormalterm.htm">
</head>
<body class="SECT1" bgcolor="#FFFFFF" text="#000000" link=
"#0000FF" vlink="#840084" alink="#0000FF">
<div class="NAVHEADER">
<table summary="Header navigation table" width="100%" border=
"0" cellpadding="0" cellspacing="0">
<tr>
<th colspan="3" align="center">LPRng-HOWTO: 1 Apr 2002
(For LPRng-3.8.10)</th>
</tr>
<tr>
<td width="10%" align="left" valign="bottom"><a href=
"x7309.htm" accesskey="P">Prev</a></td>
<td width="80%" align="center" valign="bottom">Chapter
15. Job Processing</td>
<td width="10%" align="right" valign="bottom"><a href=
"abnormalterm.htm" accesskey="N">Next</a></td>
</tr>
</table>
<hr align="LEFT" width="100%">
</div>
<div class="SECT1">
<h1 class="SECT1"><a name="NORMALTERM">15.8. Normal
Termination</a></h1>
<p>Options used:</p>
<ul>
<li>
<p><tt class="LITERAL">fq</tt> FLAG <i class=
"EMPHASIS">Form Feed on Close</i></p>
</li>
<li>
<p><tt class="LITERAL">la</tt> FLAG <i class=
"EMPHASIS">Local Printer Accounting</i></p>
</li>
<li>
<p><tt class="LITERAL">tr=</tt><i class=
"EMPHASIS">Trailer on Close</i></p>
</li>
<li>
<p><tt class="LITERAL">ae=</tt><i class=
"EMPHASIS">Accounting at end</i></p>
</li>
<li>
<p><tt class="LITERAL">save_when_done</tt> FLAG <i class=
"EMPHASIS">Save when done</i></p>
</li>
<li>
<p><tt class="LITERAL">save_on_error</tt> FLAG <i class=
"EMPHASIS">Do not delete on error</i></p>
</li>
<li>
<p><tt class="LITERAL">done_jobs=N</tt><i class=
"EMPHASIS">Save status of last N jobs</i></p>
</li>
<li>
<p><tt class="LITERAL">wait_for_eof</tt> FLAG <i class=
"EMPHASIS">Wait for EOF before closing device</i></p>
</li>
<li>
<p><tt class="LITERAL">socket_linger</tt><i class=
"EMPHASIS">socket linger timeout</i></p>
</li>
<li>
<p><tt class="LITERAL">half_close</tt> FLAG <i class=
"EMPHASIS">use shutdown() and not close()</i></p>
</li>
</ul>
<br>
<br>
<p>Sequence of Operations:</p>
<ol type="1">
<li>
<p>If we are printing and the <tt class="LITERAL">fq</tt>
flag is set and the <tt class="LITERAL">sf</tt> (suppress
interfile FF) flag is set, then the <tt class=
"LITERAL">ff</tt> (form feed) string will be interpreted
and sent to the of_fd.</p>
</li>
<li>
<p>If we are printing, the <tt class="LITERAL">tr</tt>
(trailer) string will be interpreted and sent to the
of_fd.</p>
</li>
<li>
<p>If printing and the <tt class="LITERAL">la</tt> (local
printer accounting) flag is set or transferring a job and
the <tt class="LITERAL">ar</tt> (remote accounting) flag
is set, the <tt class="LITERAL">ae</tt> is examined and
accounting is done as described for the <i class=
"EMPHASIS"><a href="opendevice.htm#ACCOUNTSTART">as</a>
field.</i></p>
</li>
<li>
<p>If the <tt class="LITERAL">:of</tt> filter is present,
its <span class="ACRONYM">STDIN</span> is closed, and the
<b class="APPLICATION">lpd</b> server waits for it to
exit. The exit status is used as described above.</p>
</li>
<li>
<p>If the device is a socket or network connection, the
socket linger time is set to <tt class=
"LITERAL">socket_linger</tt> value if nonzero.</p>
</li>
<li>
<p>If the <tt class="LITERAL">half_shut</tt> flag is set,
then a <tt class="LITERAL">shutdown(fd,WR_DONE)</tt> will
be done on the connection. This tells the TCP/IP stack
that all data transmission has been completed. Errors or
other information can still be read from the connection.
If the <tt class="LITERAL">half_shut</tt> flag is clear,
then a <tt class="LITERAL">close(fd)</tt> will be done
and no errors or other information will be read.</p>
</li>
<li>
<p>If the <tt class="LITERAL">wait_for_eof</tt> option is
true (default) then a read is done on the connection
until an EOF is found. The device (io_fd) is then
closed.</p>
</li>
<li>
<p>The job is marked as completed in the spool queue.</p>
</li>
<li>
<p>If the <tt class="LITERAL">save_when_done</tt> flag is
clear and the <tt class="LITERAL">done_jobs</tt> and <tt
class="LITERAL">done_jobs_max_age</tt> values are zero
(0), the job is removed.</p>
</li>
<li>
<p>If the <tt class="LITERAL">done_jobs</tt> or <tt
class="LITERAL">done_jobs_max_age</tt> values are
nonzero, the spool queue is periodically checked and for
an excess number of jobs or jobs with old status. This
action is suppressed if either the <tt class=
"LITERAL">save_when_done</tt> or <tt class=
"LITERAL">save_on_error</tt> flag is set.</p>
</li>
</ol>
<br>
<br>
</div>
<div class="NAVFOOTER">
<hr align="LEFT" width="100%">
<table summary="Footer navigation table" width="100%" border=
"0" cellpadding="0" cellspacing="0">
<tr>
<td width="33%" align="left" valign="top"><a href=
"x7309.htm" accesskey="P">Prev</a></td>
<td width="34%" align="center" valign="top"><a href=
"index.htm" accesskey="H">Home</a></td>
<td width="33%" align="right" valign="top"><a href=
"abnormalterm.htm" accesskey="N">Next</a></td>
</tr>
<tr>
<td width="33%" align="left" valign="top">Printing Banner
At End of Job</td>
<td width="34%" align="center" valign="top"><a href=
"jobsteps.htm" accesskey="U">Up</a></td>
<td width="33%" align="right" valign="top">Abnormal
Termination</td>
</tr>
</table>
</div>
</body>
</html>
|