1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628
|
/* Copyright (C) 2010-2011 Monty Program Ab & Vladislav Vaintroub
This program is free software; you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation; version 2 of the License.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program; if not, write to the Free Software
Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1335 USA */
/*
mysql_upgrade_service upgrades mysql service on Windows.
It changes service definition to point to the new mysqld.exe, restarts the
server and runs mysql_upgrade
*/
#define DONT_DEFINE_VOID
#include "mariadb.h"
#include <process.h>
#include <my_getopt.h>
#include <my_sys.h>
#include <m_string.h>
#include <mysql_version.h>
#include <winservice.h>
#include <windows.h>
#include <string>
extern int upgrade_config_file(const char *myini_path);
/* We're using version APIs */
#pragma comment(lib, "version")
#define USAGETEXT \
"mysql_upgrade_service.exe Ver 1.00 for Windows\n" \
"Copyright (C) 2010-2011 Monty Program Ab & Vladislav Vaintroub" \
"This software comes with ABSOLUTELY NO WARRANTY. This is free software,\n" \
"and you are welcome to modify and redistribute it under the GPL v2 license\n" \
"Usage: mysql_upgrade_service.exe [OPTIONS]\n" \
"OPTIONS:"
static char mysqld_path[MAX_PATH];
static char mysqlupgrade_path[MAX_PATH];
static char defaults_file_param[MAX_PATH + 16]; /*--defaults-file=<path> */
static char logfile_path[MAX_PATH];
char my_ini_bck[MAX_PATH];
mysqld_service_properties service_properties;
static char *opt_service;
static SC_HANDLE service;
static SC_HANDLE scm;
HANDLE mysqld_process; // mysqld.exe started for upgrade
DWORD initial_service_state= UINT_MAX; // initial state of the service
HANDLE logfile_handle;
/*
Startup and shutdown timeouts, in seconds.
Maybe,they can be made parameters
*/
static unsigned int startup_timeout= 60;
static unsigned int shutdown_timeout= 60*60;
static struct my_option my_long_options[]=
{
{"help", '?', "Display this help message and exit.", 0, 0, 0, GET_NO_ARG,
NO_ARG, 0, 0, 0, 0, 0, 0},
{"service", 'S', "Name of the existing Windows service",
&opt_service, &opt_service, 0, GET_STR, REQUIRED_ARG, 0, 0, 0, 0, 0, 0},
{0, 0, 0, 0, 0, 0, GET_NO_ARG, NO_ARG, 0, 0, 0, 0, 0, 0}
};
static my_bool
get_one_option(const struct my_option *opt, const char *, const char *)
{
DBUG_ENTER("get_one_option");
switch (opt->id) {
case '?':
printf("%s\n", USAGETEXT);
my_print_help(my_long_options);
exit(0);
break;
}
DBUG_RETURN(0);
}
static void log(const char *fmt, ...)
{
va_list args;
/* Print the error message */
va_start(args, fmt);
vfprintf(stdout,fmt, args);
va_end(args);
fputc('\n', stdout);
fflush(stdout);
}
static void die(const char *fmt, ...)
{
va_list args;
DBUG_ENTER("die");
/* Print the error message */
va_start(args, fmt);
fprintf(stderr, "FATAL ERROR: ");
vfprintf(stderr, fmt, args);
fputc('\n', stderr);
if (logfile_path[0])
{
fprintf(stderr, "Additional information can be found in the log file %s",
logfile_path);
}
va_end(args);
fputc('\n', stderr);
fflush(stdout);
/* Cleanup */
if (my_ini_bck[0])
{
MoveFileEx(my_ini_bck, service_properties.inifile,MOVEFILE_REPLACE_EXISTING);
}
/*
Stop service that we started, if it was not initially running at
program start.
*/
if (initial_service_state != UINT_MAX && initial_service_state != SERVICE_RUNNING)
{
SERVICE_STATUS service_status;
ControlService(service, SERVICE_CONTROL_STOP, &service_status);
}
if (scm)
CloseServiceHandle(scm);
if (service)
CloseServiceHandle(service);
/* Stop mysqld.exe, if it was started for upgrade */
if (mysqld_process)
TerminateProcess(mysqld_process, 3);
if (logfile_handle)
CloseHandle(logfile_handle);
my_end(0);
exit(1);
}
#define WRITE_LOG(fmt,...) {\
char log_buf[1024]; \
DWORD nbytes; \
snprintf(log_buf,sizeof(log_buf), fmt, __VA_ARGS__);\
WriteFile(logfile_handle,log_buf, (DWORD)strlen(log_buf), &nbytes , 0);\
}
/*
spawn-like function to run subprocesses.
We also redirect the full output to the log file.
Typical usage could be something like
run_tool(P_NOWAIT, "cmd.exe", "/c" , "echo", "foo", NULL)
@param wait_flag (P_WAIT or P_NOWAIT)
@program program to run
Rest of the parameters is NULL terminated strings building command line.
@return intptr containing either process handle, if P_NOWAIT is used
or return code of the process (if P_WAIT is used)
*/
static intptr_t run_tool(int wait_flag, const char *program,...)
{
static char cmdline[32*1024];
char *end;
va_list args;
va_start(args, program);
if (!program)
die("Invalid call to run_tool");
end= strxmov(cmdline, "\"", program, "\"", NullS);
for(;;)
{
char *param= va_arg(args,char *);
if(!param)
break;
end= strxmov(end, " \"", param, "\"", NullS);
}
va_end(args);
/* Create output file if not alredy done */
if (!logfile_handle)
{
char tmpdir[FN_REFLEN];
GetTempPath(FN_REFLEN, tmpdir);
sprintf_s(logfile_path, "%smysql_upgrade_service.%s.log", tmpdir,
opt_service);
SECURITY_ATTRIBUTES attr= {0};
attr.nLength= sizeof(SECURITY_ATTRIBUTES);
attr.bInheritHandle= TRUE;
logfile_handle= CreateFile(logfile_path, FILE_APPEND_DATA,
FILE_SHARE_READ|FILE_SHARE_WRITE, &attr, CREATE_ALWAYS, 0, NULL);
if (logfile_handle == INVALID_HANDLE_VALUE)
{
die("Cannot open log file %s, windows error %u",
logfile_path, GetLastError());
}
}
WRITE_LOG("Executing %s\r\n", cmdline);
/* Start child process */
STARTUPINFO si= {0};
si.cb= sizeof(si);
si.hStdInput= GetStdHandle(STD_INPUT_HANDLE);
si.hStdError= logfile_handle;
si.hStdOutput= logfile_handle;
si.dwFlags= STARTF_USESTDHANDLES;
PROCESS_INFORMATION pi;
if (!CreateProcess(NULL, cmdline, NULL,
NULL, TRUE, NULL, NULL, NULL, &si, &pi))
{
die("CreateProcess failed (commandline %s)", cmdline);
}
CloseHandle(pi.hThread);
if (wait_flag == P_NOWAIT)
{
/* Do not wait for process to complete, return handle. */
return (intptr_t)pi.hProcess;
}
/* Wait for process to complete. */
if (WaitForSingleObject(pi.hProcess, INFINITE) != WAIT_OBJECT_0)
{
die("WaitForSingleObject() failed");
}
DWORD exit_code;
if (!GetExitCodeProcess(pi.hProcess, &exit_code))
{
die("GetExitCodeProcess() failed");
}
return (intptr_t)exit_code;
}
void stop_mysqld_service()
{
DWORD needed;
SERVICE_STATUS_PROCESS ssp;
int timeout= shutdown_timeout*1000;
for(;;)
{
if (!QueryServiceStatusEx(service, SC_STATUS_PROCESS_INFO,
(LPBYTE)&ssp,
sizeof(SERVICE_STATUS_PROCESS),
&needed))
{
die("QueryServiceStatusEx failed (%u)\n", GetLastError());
}
/*
Remember initial state of the service, we will restore it on
exit.
*/
if(initial_service_state == UINT_MAX)
initial_service_state= ssp.dwCurrentState;
switch(ssp.dwCurrentState)
{
case SERVICE_STOPPED:
return;
case SERVICE_RUNNING:
if(!ControlService(service, SERVICE_CONTROL_STOP,
(SERVICE_STATUS *)&ssp))
die("ControlService failed, error %u\n", GetLastError());
case SERVICE_START_PENDING:
case SERVICE_STOP_PENDING:
if(timeout < 0)
die("Service does not stop after %d seconds timeout",shutdown_timeout);
Sleep(100);
timeout -= 100;
break;
default:
die("Unexpected service state %d",ssp.dwCurrentState);
}
}
}
/*
Shutdown mysql server. Not using mysqladmin, since
our --skip-grant-tables do not work anymore after mysql_upgrade
that does "flush privileges". Instead, the shutdown event is set.
*/
#define OPEN_EVENT_RETRY_SLEEP_MS 100
#define OPEN_EVENT_MAX_RETRIES 50
void initiate_mysqld_shutdown()
{
char event_name[32];
DWORD pid= GetProcessId(mysqld_process);
sprintf_s(event_name, "MySQLShutdown%d", pid);
HANDLE shutdown_handle;
for (int i= 0;; i++)
{
shutdown_handle= OpenEvent(EVENT_MODIFY_STATE, FALSE, event_name);
if(shutdown_handle != nullptr || i == OPEN_EVENT_MAX_RETRIES)
break;
if (WaitForSingleObject(mysqld_process, OPEN_EVENT_RETRY_SLEEP_MS) !=
WAIT_TIMEOUT)
{
die("server process exited before shutdown event was created");
break;
}
}
if (!shutdown_handle)
{
die("OpenEvent() failed for shutdown event");
}
if(!SetEvent(shutdown_handle))
{
die("SetEvent() failed");
}
}
static void get_service_config()
{
scm = OpenSCManager(NULL, NULL, SC_MANAGER_ALL_ACCESS);
if (!scm)
die("OpenSCManager failed with %u", GetLastError());
service = OpenService(scm, opt_service, SERVICE_ALL_ACCESS);
if (!service)
die("OpenService failed with %u", GetLastError());
alignas(QUERY_SERVICE_CONFIGW) BYTE config_buffer[8 * 1024];
LPQUERY_SERVICE_CONFIGW config = (LPQUERY_SERVICE_CONFIGW)config_buffer;
DWORD size = sizeof(config_buffer);
DWORD needed;
if (!QueryServiceConfigW(service, config, size, &needed))
die("QueryServiceConfig failed with %u", GetLastError());
if (get_mysql_service_properties(config->lpBinaryPathName, &service_properties))
{
die("Not a valid MySQL service");
}
int my_major = MYSQL_VERSION_ID / 10000;
int my_minor = (MYSQL_VERSION_ID % 10000) / 100;
int my_patch = MYSQL_VERSION_ID % 100;
if (my_major < service_properties.version_major ||
(my_major == service_properties.version_major && my_minor < service_properties.version_minor))
{
die("Can not downgrade, the service is currently running as version %d.%d.%d"
", my version is %d.%d.%d", service_properties.version_major, service_properties.version_minor,
service_properties.version_patch, my_major, my_minor, my_patch);
}
if (service_properties.inifile[0] == 0)
{
/*
Weird case, no --defaults-file in service definition, need to create one.
*/
sprintf_s(service_properties.inifile, MAX_PATH, "%s\\my.ini", service_properties.datadir);
}
sprintf(defaults_file_param, "--defaults-file=%s", service_properties.inifile);
}
/*
Change service configuration (binPath) to point to mysqld from
this installation.
*/
static void change_service_config()
{
char buf[MAX_PATH];
char commandline[3 * MAX_PATH + 19];
int i;
/*
Write datadir to my.ini, after converting backslashes to
unix style slashes.
*/
if (service_properties.datadir[0])
{
strcpy_s(buf, MAX_PATH, service_properties.datadir);
for (i= 0; buf[i]; i++)
{
if (buf[i] == '\\')
buf[i]= '/';
}
WritePrivateProfileString("mysqld", "datadir", buf,
service_properties.inifile);
}
/*
Remove basedir from defaults file, otherwise the service wont come up in
the new version, and will complain about mismatched message file.
*/
WritePrivateProfileString("mysqld", "basedir",NULL, service_properties.inifile);
sprintf(defaults_file_param,"--defaults-file=%s", service_properties.inifile);
sprintf_s(commandline, "\"%s\" \"%s\" \"%s\"", mysqld_path,
defaults_file_param, opt_service);
if (!ChangeServiceConfig(service, SERVICE_NO_CHANGE, SERVICE_NO_CHANGE,
SERVICE_NO_CHANGE, commandline, NULL, NULL, NULL, NULL, NULL, NULL))
{
die("ChangeServiceConfig failed with %u", GetLastError());
}
}
/**
Waits until starting server can be connected to, via given named pipe, with timeout
Dies if either server process exited meanwhile, or when timeout was exceeded.
*/
static void wait_for_server_startup(HANDLE process, const char *named_pipe, DWORD timeout_sec)
{
unsigned long long end_time= GetTickCount64() + 1000ULL*timeout_sec;
for (;;)
{
if (WaitNamedPipe(named_pipe, 0))
return;
if (GetTickCount64() >= end_time)
die("Server did not startup after %lu seconds", timeout_sec);
if (WaitForSingleObject(process, 100) != WAIT_TIMEOUT)
die("Server did not start");
}
}
int main(int argc, char **argv)
{
int error;
MY_INIT(argv[0]);
char bindir[FN_REFLEN];
char *p;
/* Parse options */
if ((error= handle_options(&argc, &argv, my_long_options, get_one_option)))
die("");
if (!opt_service)
die("--service=# parameter is mandatory");
/*
Get full path to mysqld, we need it when changing service configuration.
Assume mysqld.exe in the same directory as this program.
mysql_upgrade.exe is either in the same directory, or pointed to by
MARIADB_UPGRADE_EXE environment variable (in case of MTR running it)
*/
GetModuleFileName(NULL, bindir, FN_REFLEN);
p= strrchr(bindir, FN_LIBCHAR);
if(p)
{
*p= 0;
}
sprintf_s(mysqld_path, "%s\\mysqld.exe", bindir);
sprintf_s(mysqlupgrade_path, "%s\\mysql_upgrade.exe", bindir);
if (access(mysqld_path, 0))
die("File %s does not exist", mysqld_path);
if (access(mysqlupgrade_path, 0))
{
/* Try to get path from environment variable, set by MTR */
char *alt_mysqlupgrade_path= getenv("MARIADB_UPGRADE_EXE");
if (alt_mysqlupgrade_path)
sprintf_s(mysqlupgrade_path, "%s", alt_mysqlupgrade_path);
}
if (access(mysqlupgrade_path, 0))
die("File %s does not exist", mysqld_path);
/*
Messages written on stdout should not be buffered, GUI upgrade program
reads them from pipe and uses as progress indicator.
*/
setvbuf(stdout, NULL, _IONBF, 0);
int phase = 0;
int max_phases=10;
get_service_config();
bool my_ini_exists;
bool old_mysqld_exe_exists;
log("Phase %d/%d: Stopping service", ++phase,max_phases);
stop_mysqld_service();
my_ini_exists = (GetFileAttributes(service_properties.inifile) != INVALID_FILE_ATTRIBUTES);
if (!my_ini_exists)
{
HANDLE h = CreateFile(service_properties.inifile, GENERIC_WRITE, FILE_SHARE_READ|FILE_SHARE_WRITE,
0, CREATE_NEW, 0 ,0);
if (h != INVALID_HANDLE_VALUE)
{
CloseHandle(h);
}
else if (GetLastError() != ERROR_FILE_EXISTS)
{
die("Can't create ini file %s, last error %u", service_properties.inifile, GetLastError());
}
}
old_mysqld_exe_exists= (GetFileAttributes(service_properties.mysqld_exe) !=
INVALID_FILE_ATTRIBUTES);
bool do_start_stop_server = old_mysqld_exe_exists && initial_service_state != SERVICE_RUNNING;
log("Phase %d/%d: Start and stop server in the old version, to avoid crash recovery %s", ++phase, max_phases,
do_start_stop_server?",this can take some time":"(skipped)");
char socket_param[FN_REFLEN];
sprintf_s(socket_param, "--socket=mysql_upgrade_service_%u",
GetCurrentProcessId());
DWORD start_duration_ms = 0;
char pipe_name[64];
snprintf(pipe_name, sizeof(pipe_name),
"\\\\.\\pipe\\mysql_upgrade_service_%lu", GetCurrentProcessId());
if (do_start_stop_server)
{
/* Start/stop server with --loose-innodb-fast-shutdown=1 */
mysqld_process = (HANDLE)run_tool(P_NOWAIT, service_properties.mysqld_exe,
defaults_file_param, "--loose-innodb-fast-shutdown=1", "--skip-networking",
"--enable-named-pipe", socket_param, "--skip-slave-start", NULL);
if (mysqld_process == INVALID_HANDLE_VALUE)
{
die("Cannot start mysqld.exe process, last error =%u", GetLastError());
}
wait_for_server_startup(mysqld_process, pipe_name, startup_timeout);
// Server started, shut it down.
initiate_mysqld_shutdown();
if (WaitForSingleObject((HANDLE)mysqld_process, shutdown_timeout * 1000) != WAIT_OBJECT_0)
{
die("Could not shutdown server");
}
DWORD exit_code;
if (!GetExitCodeProcess((HANDLE)mysqld_process, &exit_code))
{
die("Could not get server's exit code");
}
if (exit_code)
{
die("Could not get successfully shutdown server (exit code %u)",exit_code);
}
CloseHandle(mysqld_process);
}
log("Phase %d/%d: Fixing server config file%s", ++phase, max_phases,
my_ini_exists ? "" : "(skipped)");
snprintf(my_ini_bck, sizeof(my_ini_bck), "%s.BCK",
service_properties.inifile);
CopyFile(service_properties.inifile, my_ini_bck, FALSE);
upgrade_config_file(service_properties.inifile);
/*
Start mysqld.exe as non-service skipping privileges (so we do not
care about the password). But disable networking and enable pipe
for communication, for security reasons.
*/
log("Phase %d/%d: Starting mysqld for upgrade",++phase,max_phases);
mysqld_process= (HANDLE)run_tool(P_NOWAIT, mysqld_path,
defaults_file_param, "--skip-networking", "--skip-grant-tables",
"--enable-named-pipe", socket_param,"--skip-slave-start", NULL);
if (mysqld_process == INVALID_HANDLE_VALUE)
{
die("Cannot start mysqld.exe process, errno=%d", errno);
}
log("Phase %d/%d: Waiting for startup to complete",++phase,max_phases);
wait_for_server_startup(mysqld_process, pipe_name, startup_timeout);
log("Phase %d/%d: Running mysql_upgrade",++phase,max_phases);
int upgrade_err= (int) run_tool(P_WAIT, mysqlupgrade_path,
"--protocol=pipe", "--force", socket_param,
NULL);
if (upgrade_err)
die("mysql_upgrade failed with error code %d\n", upgrade_err);
log("Phase %d/%d: Changing service configuration", ++phase, max_phases);
change_service_config();
log("Phase %d/%d: Initiating server shutdown",++phase, max_phases);
initiate_mysqld_shutdown();
log("Phase %d/%d: Waiting for shutdown to complete",++phase, max_phases);
if (WaitForSingleObject(mysqld_process, shutdown_timeout*1000)
!= WAIT_OBJECT_0)
{
/* Shutdown takes too long */
die("mysqld does not shutdown.");
}
CloseHandle(mysqld_process);
mysqld_process= NULL;
log("Phase %d/%d: Starting service%s",++phase,max_phases,
(initial_service_state == SERVICE_RUNNING)?"":" (skipped)");
if (initial_service_state == SERVICE_RUNNING)
{
StartService(service, NULL, NULL);
}
log("Service '%s' successfully upgraded.\nLog file is written to %s",
opt_service, logfile_path);
CloseServiceHandle(service);
CloseServiceHandle(scm);
if (logfile_handle)
CloseHandle(logfile_handle);
if(my_ini_bck[0])
{
DeleteFile(my_ini_bck);
}
my_end(0);
exit(0);
}
|