1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296
|
Spare N/A N/A N/A N/A N/A See Note (3) 1
Loop Back Test Status Integer*2 N/A 0 to 3 1 0=Pass, 1=Fail, 2=Timeout, 3=Not Tested (1) 2
T1 Output Frames The number of octets received on interface, including frame octets Integer*4 octet 0 to 232-1 1 N/A 3 - 4
T1 Input Frames The number of octets sent on interface, including frame octets Integer*4 octet 0 to 232-1 1 N/A 5 - 6
Router Memory Used Bytes currently in use by applications on managed device Integer*4 byte 0 to 232-1 1 N/A 7 - 8
Router Memory Free Bytes currently free on managed device Integer*4 byte 0 to 232-1 1 N/A 9 - 10
Router Memory Utilization Integer*2 % 0 to 100 1 N/A 11
Spare N/A N/A N/A N/A N/A See Note (3) 12
CSU Loss of Signal Number of times Loss of Signal event detected Integer*4 N/A 0 to 232-1 1 N/A 13 - 14
CSU Loss of Frames Number of times Loss of Frames event detected Integer*4 N/A 0 to 232-1 1 N/A 15 - 16
CSU Yellow Alarms Number of times Resource Availability Indication (RAI) (yellow) alarm received. Integer*4 N/A 0 to 232-1 1 N/A 17 - 18
CSU Blue Alarms Number of times Alarm Indication Signal (AIS) (blue) alarm received. Integer*4 N/A 0 to 232-1 1 N/A 19 - 20
CSU 24hr Errored Seconds Number of errored seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 21 - 22
CSU 24hr Severely Errored Seconds Number of severely errored seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 23 - 24
CSU 24hr Severely Errored Framing Seconds Number of severely errored framing seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 25 - 26
CSU 24hr Unavailable Seconds Number of unavailable seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 27 - 28
CSU 24hr Controlled Slip Seconds Number of controlled slip seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 29 - 30
CSU 24hr Path Coding Violations Number of path coding violations in previous 24 hours. Integer*4 N/A 0 to 232-1 1 N/A 31 - 32
CSU 24hr Line Errored Seconds Number of line errored seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 33 - 34
CSU 24hr Bursty Errored Seconds Number of bursty errored seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 35 - 36
CSU 24hr Degraded Minutes Number of degraded minutes in previous 24 hours. Integer*4 min 0 to 232-1 1 N/A 37 - 38
LAN Switch Memory Used Bytes currently in use by applications on this device Integer*4 byte 0 to 232-1 1 N/A 39 - 40
LAN Switch Memory Free Bytes currently free on this device Integer*4 byte 0 to 232-1 1 N/A 41 - 42
LAN Switch Memory Utilization Integer*2 % 0 to 100 1 N/A 43
Spare N/A N/A N/A N/A N/A See Note (3) 44
NTP Rejected Packets Number of packets rejected by NTP application layer Integer*4 N/A 0 to 232-1 1 N/A 45 - 46
NTP Estimated Time Error Current estimated time error of the time server SInteger*4 usec -(231) to +(231-1) 1 N/A 47 - 48
GPS Satellites Current number of GPS satellites used in position and time fix calculation SInteger*4 N/A -(231) to +(231-1) 1 N/A 49 - 50
GPS Max Signal Strength Strongest signal strength of all tracking satellites as seen by receiver SInteger*4 dB -(231) to +(231-1) 1 N/A 51 - 52
IPC Status Status of the communications between channels on a redundant system. N/A on a Single channel system. Integer*2 N/A 0 to 2 1 0=OK, 1=Fail, 2=N/A 53
Commanded Channel Control Indicates which channel the RDA has commanded to be the controlling channel. This is not necessarily the channel which is in control. Integer*2 N/A 0 to 2 1 0=N/A, 1=Channel 1, 2=Channel 2 54
DAU Test 0 Tests the performance of the DAU A/D Mutiplexer with a known low voltage input. Integer*2 N/A 0 to 255 1 10 = Normal, 7-11 = Acceptable, All other values= Fault 55
DAU Test 1 Tests the performance of the DAU A/D Mutiplexer with a known medium voltage input. Integer*2 N/A 0 to 255 1 127 = Normal, 118-136 = Acceptable, All other values=Fault 56
DAU Test 2 Tests the performance of the DAU A/D Mutiplexer with a known high voltage input. Integer*2 N/A 0 to 255 1 245 = Normal, 221-252 = Acceptable, All other values=Fault 57
AME Polarization Integer*2 N/A 0 to 2 1 0 = H Only 1 = H + V 2 = V Only 58
AME Internal Temperature Real*4 deg C -40.0 to +125.0 0.1 N/A 59-60
AME Receiver Module Temperature Real*4 deg C -40.0 to +125.0 0.1 N/A 61-62
AME BITE/CAL Module Temperature Real*4 deg C -40.0 to +125.0 0.1 N/A 63-64
AME Peltier Pulse Width Modulation Integer*2 % 0 to 100 1 N/A 65
AME Peltier Status Integer*2 N/A 0 to 1 1 0 = OFF 1 = ON 66
AME A/D Converter Status Integer*2 N/A 0 to 1 1 0 = OK 1 = FAIL 67
AME State Integer*2 N/A 0 to 3 1 0 = START 1 = RUNNING 2 = FLASH 3 = ERROR 68
AME +3.3V PS Voltage Real*4 V 0.00 to 4.09 0.01 N/A 69-70
AME +5V PS Voltage Real*4 V 0.00 to 6.10 0.01 N/A 71-72
AME +6.5V PS Voltage Real*4 V 0.00 to 7.50 0.01 N/A 73-74
AME +15V PS Voltage Real*4 V 0.00 to 19.00 0.01 N/A 75-76
AME +48V PS Voltage Real*4 V 0.00 to 60.00 0.01 N/A 77-78
AME STALO Power Real*4 V 0.00 to 4.09 0.01 N/A 79-80
Peltier Current Real*4 A 0.00 to 16.00 0.01 N/A 81-82
ADC Calibration Reference Voltage Real*4 V 0.000 to 2.048 0.001 N/A 83-84
AME Mode Integer*2 N/A 0 to 1 1 0 = READY 1 = MAINTENANCE 85
AME Peltier Mode Integer*2 N/A 0 to 1 1 0 = COOL 1 = HEAT 86
AME Peltier Inside Fan Current Real*4 A 0.00 to 4.00 0.01 N/A 87-88
AME Peltier Outside Fan Current Real*4 A 0.00 to 4.00 0.01 N/A 89-90
Horizontal TR Limiter Voltage Real*4 V 0.00 to 5.00 0.01 N/A 91-92
Vertical TR Limiter Voltage Real*4 V 0.00 to 5.00 0.01 N/A 93-94
ADC Calibration Offset Voltage Real*4 mV -50.000 to +50.000 0.01 N/A 95-96
ADC Calibration Gain Correction Real*4 N/A 0.990 to 1.010 0.001 N/A 97-98
Power UPS Battery Status Integer*4 N/A 1 to 3 1 1=Unknown, 2=OK, 3=Low 99 - 100
UPS Time on Battery Integer*4 s 0 to 232-1 1 N/A 101 - 102
UPS Battery Temperature Real*4 deg C N/A 0.01 N/A 103 - 104
UPS Output Voltage Real*4 V 114.00 to 126.00 0.01 N/A 105 - 106
UPS Output Frequency Real*4 Hz 57.00 to 63.00 0.01 N/A 107 - 108
UPS Output Current Real*4 A 0.00 to 12.00 0.01 N/A 109 - 110
Power Administrator Load Real*4 A 0.00 to 12.00 0.01 N/A 111 - 112
Spare N/A N/A N/A N/A N/A See Note (3) 113 - 136
+5 VDC PS Integer*2 N/A 0 to 1 1 0=OK,1=Fail 137
+15 VDC PS Integer*2 N/A 0 to 1 1 0=OK,1=Fail 138
+28 VDC PS Integer*2 N/A 0 to 1 1 0=OK,1=Fail 139
-15 VDC PS Integer*2 N/A 0 to 1 1 0=OK,1=Fail 140
+45 VDC PS Integer*2 N/A 0 to 1 1 0=OK,1=Fail 141
Filament PS Voltage Integer*2 N/A 0 to 1 1 0=OK,1=Fail 142
Vacuum Pump PS Voltage Integer*2 N/A 0 to 1 1 0=OK,1=Fail 143
Focus Coil PS Voltage Integer*2 N/A 0 to 1 1 0=OK,1=Fail 144
Filament PS Integer*2 N/A 0 to 1 1 0=On, 1=Off 145
Klystron Warmup Integer*2 N/A 0 to 1 1 0=Normal, 1=Preheat 146
Transmitter Available Integer*2 N/A 0 to 1 1 0=Yes, 1=No 147
WG Switch Position Integer*2 N/A 0 to 1 1 0=Antenna, 1=Dummy Load 148
WG/PFN Transfer Interlock Integer*2 N/A 0 to 1 1 0=OK, 1=Open 149
Maintenance Mode Integer*2 N/A 0 to 1 1 0= No, 1=Yes 150
Maintenance Required Integer*2 N/A 0 to 1 1 0=No, 1=Required 151
PFN Switch Position Integer*2 N/A 0 to 1 1 0=Short Pulse, 1=Long Pulse 152
Modulator Overload Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 153
Modulator Inv Current Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 154
Modulator Switch Fail Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 155
Main Power Voltage Integer*2 N/A 0 to 1 1 0=OK, 1=Over 156
Charging System Fail Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 157
Inverse Diode Current Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 158
Trigger Amplifier Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 159
Circulator Temperature Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 160
Spectrum Filter Pressure Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 161
WG ARC/VSWR Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 162
Cabinet Interlock Integer*2 N/A 0 to 1 1 0=OK, 1=Open 163
Cabinet Air Temperature Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 164
Cabinet Airflow Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 165
Klystron Current Integer*2 N/A 0 to 1 1 N/A 166
Klystron Filament Current Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 167
Klystron Vacion Current Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 168
Klystron Air Temperature Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 169
Klystron Airflow Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 170
Modulator Switch Maintenance Integer*2 N/A 0 to 1 1 0=OK, 1=Required 171
Post Charge Regulator Maintenance Integer*2 N/A 0 to 1 1 0=OK, 1=Maintenance 172
WG Pressure/Humidity Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 173
Transmitter Overvoltage Integer*2 N/A 0 to 1 1 0=OK, 1=Over 174
Transmitter Overcurrent Integer*2 N/A 0 to 1 1 0=OK, 1=Over 175
Focus Coil Current Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 176
Focus Coil Airflow Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 177
Oil Temperature Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 178
PRF Limit Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 179
Transmitter Oil Level Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 180
Transmitter Battery Charging Integer*2 N/A 0 to 1 1 0=Yes, 1=No 181
High Voltage (HV) Status Integer*2 N/A 0 to 1 1 0=On, 1=Off 182
Transmitter Recycling Summary Integer*2 N/A 0 to 1 1 0=Normal, 1=Recycling 183
Transmitter Inoperable Integer*2 N/A 0 to 1 1 0=OK, 1=INOP 184
Transmitter Air Filter Integer*2 N/A 0 to 1 1 0=Dirty, 1=OK 185
Zero Test Bit 0 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 186
Zero Test Bit 1 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 187
Zero Test Bit 2 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 188
Zero Test Bit 3 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 189
Zero Test Bit 4 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 190
Zero Test Bit 5 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 191
Zero Test Bit 6 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 192
Zero Test Bit 7 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 193
One Test Bit 0 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 194
One Test Bit 1 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 195
One Test Bit 2 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 196
One Test Bit 3 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 197
One Test Bit 4 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 198
One Test Bit 5 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 199
One Test Bit 6 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 200
One Test Bit 7 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 201
XMTR/DAU Interface Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 202
Transmitter Summary Status Integer*2 N/A 0 to 4 1 0=Ready, 1=Alarm, 2=Maintenance, 3=Recycle, 4=Preheat 203
Spare N/A N/A N/A N/A N/A See Note (3) 204
Transmitter RF Power (Sensor) Real*4 mW 0.0000 to 10.0000 .0001 N/A 205 - 206
Horizontal XMTR Peak Power Real*4 kW 0 to 999.9 0.1 N/A 207 - 208
XMTR Peak Power Real*4 kW 0 to 999.9 0.1 N/A 209 - 210
Vertical XMTR Peak Power Real*4 kW 0 to 999.9 0.1 N/A 211 - 212
XMTR RF Avg Power Real*4 W 0 to 9999.9 0.1 N/A 213 - 214
XMTR Power Meter Zero Integer*2 N/A 0 to 255 1 N/A 215
Spare N/A N/A N/A N/A See Note (3) 216
XMTR Recycle Count Integer*4 N/A 0 to 999,999 1 N/A 217 - 218
Receiver Bias Real*4 dB 0 to 999.9999 0.0001 N/A 219 - 220
Transmit Imbalance Real*4 dB 0 to 999.99 0.01 N/A 221 - 222
Spare N/A N/A N/A N/A N/A See Note (3) 223 - 228
AC Unit #1 Compressor Shut off Integer*2 N/A 0 to 1 1 0=OK, 1=Shutoff 229
AC Unit #2 Compressor Shut off Integer*2 N/A 0 to 1 1 0=OK, 1=Shutoff 230
Generator Maintenance Required Integer*2 N/A 0 to 1 1 0=Yes, 1=No 231
Generator Battery Voltage Integer*2 N/A 0 to 1 1 0=Low, 1= OK 232
Generator Engine Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 233
Generator Volt/Frequency Integer*2 N/A 0 to 1 1 0=Not available, 1=Available 234
Power Source Integer*2 N/A 0 to 1 1 0=Utility Power, 1=Generator Power 235
Transitional Power Source (TPS) Integer*2 N/A 0 to 1 1 0=OK, 1=Off 236
Generator Auto/Run/Off Switch Integer*2 N/A 0 to 1 1 0=Manual, 1=Auto 237
Aircraft Hazard Lighting Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 238
DAU UART Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 239
Spare N/A N/A N/A N/A 1 See Note (3) 240 - 249
Equipment Shelter Fire Detection System Integer*2 N/A 0 to 1 1 0 = OK, 1 = Fail 250
Equipment Shelter Fire/Smoke Integer*2 N/A 0 to 1 1 0=OK, 1=Fire 251
Generator Shelter Fire/Smoke Integer*2 N/A 0 to 1 1 0=Fire, 1=OK 252
Utility Voltage/Frequency Integer*2 N/A 0 to 1 1 0=Not available, 1=Available 253
Site Security Alarm Integer*2 N/A 0 to 1 1 0=Alarm, 1=OK 254
Security Equipment Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 255
Security System Integer*2 N/A 0 to 1 1 0=Disabled, 1=OK 256
Receiver Connected to Antenna Integer*2 N/A 0 to 2 1 N/A on a single channel system. 0=Connected, 1=Not Connected, 2=N/A 257
Radome Hatch Integer*2 N/A 0 to 1 1 0=Open, 1=Closed 258
AC Unit #1 Filter Dirty Integer*2 N/A 0 to 1 1 0=Dirty, 1=OK 259
AC Unit #2 Filter Dirty Integer*2 N/A 0 to 1 N/A 0=Dirty, 1=OK 260
Equipment Shelter Temperature Real*4 deg C 0.00 to +50.00 0.01 N/A 261 - 262
Outside Ambient Temperature Real*4 deg C -50.00 to +50.00 0.01 N/A 263 - 264
Transmitter Leaving Air Temp Real*4 deg C -10.00 to +60.00 0.01 N/A 265 - 266
AC Unit #1 Discharge Air Temp Real*4 deg C 0.00 to +50.00 0.01 N/A 267 - 268
Generator Shelter Temperature Real*4 deg C 0.00 to +50.00 0.01 N/A 269 - 270
Radome Air Temperature Real*4 deg C -50.00 to +50.00 0.01 N/A 271 - 272
AC Unit #2 Discharge Air Temp Real*4 deg C 0.00 to +50.00 0.01 N/A 273 - 274
DAU +15v PS Real*4 V 0.00 to 20.00 0.01 N/A 275 - 276
DAU -15v PS Real*4 V -20.00 to 0.00 0.01 N/A 277 - 278
DAU +28v PS Real*4 V 0.00 to 37.40 0.01 N/A 279 - 280
DAU +5v PS Real*4 V 0.00 to 6.64 0.01 N/A 281 - 282
Converted Generator Fuel Level Integer*2 % 0 to 100 1 N/A 283
Spare N/A N/A N/A N/A N/A See Note (3) 284 - 290
+28v PS Real*4 V 0.00 to 40.80 0.01 N/A 291 - 292
Pedestal +15v PS Real*4 V 0.00 to 20.00 0.01 N/A 293 - 294
Encoder +5v PS Real*4 V 0.00 to 18.36 0.01 N/A 295 - 296
Pedestal +5v PS Real*4 V 0.00 to 6.64 0.01 N/A 297 - 298
Pedestal -15v PS Real*4 V -20.00 to 0.00 0.01 N/A 299 - 300
+150V Overvoltage Integer*2 N/A 0 to 1 1 0=OK, 1=Overvoltage 301
+150V Undervoltage Integer*2 N/A 0 to 1 1 0=OK, 1=Overvoltage 302
Elevation Servo Amp Inhibit Integer*2 N/A 0 to 1 1 0=Normal, 1=Inhibit 303
Elevation Servo Amp Short Circuit Integer*2 N/A 0 to 1 1 0=Normal, 1=Short Circuit 304
Elevation Servo Amp Overtemp Integer*2 N/A 0 to 1 1 0=Normal, 1=Overtemp 305
Elevation Motor Overtemp Integer*2 N/A 0 to 1 1 0=OK, 1=Overtemp 306
Elevation Stow Pin Integer*2 N/A 0 to 1 1 0=Operational, 1=Engaged 307
Elevation PCU Parity Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 308
Elevation Dead Limit Integer*2 N/A 0 to 1 1 0=OK, 1=In Limit 309
Elevation +Normal Limit Integer*2 N/A 0 to 1 1 0=OK, 1=In Limit 310
Elevation -Normal Limit Integer*2 N/A 0 to 1 1 0=OK, 1=In Limit 311
Elevation Encoder Light Integer*2 N/A 0 to 1 1 1=Fail, 0=OK 312
Elevation Gearbox Oil Integer*2 N/A 0 to 1 1 0=OK, 1=Oil Level Low 313
Elevation Handwheel Integer*2 N/A 0 to 1 1 0=Operational, 1=Engaged 314
Elevation Amp PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 315
Azimuth Servo Amp Inhibit Integer*2 N/A 0 to 1 1 0=OK, 1=Inhibit 316
Azimuth Servo Amp Short Circuit Integer*2 N/A 0 to 1 1 1=Short Circuit, 0=OK 317
Azimuth Servo Amp Overtemp Integer*2 N/A 0 to 1 1 0=OK, 1=Overtemp 318
Azimuth Motor Overtemp Integer*2 N/A 0 to 1 1 0=OK, 1=Overtemp 319
Azimuth Stow Pin Integer*2 N/A 0 to 1 1 0=Operational, 1=Engaged 320
Azimuth PCU Parity Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 321
Azimuth Encoder Light Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 322
Azimuth Gearbox Oil Integer*2 N/A 0 to 1 1 0=OK, 1=Oil Level Low 323
Azimuth Bull Gear Oil Integer*2 N/A 0 to 1 1 0=OK, 1=Oil Level Low 324
Azimuth Handwheel Integer*2 N/A 0 to 1 1 0=Operational, 1=Engaged 325
Azimuth Servo Amp PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 326
Servo Integer*2 N/A 0 to 1 1 0=On, 1=Off 327
Pedestal Interlock Switch Integer*2 N/A 0 to 1 1 0=Operational, 1=Safe 328
Spare N/A N/A N/A N/A N/A See Note (3). 329
Spare N/A N/A N/A N/A N/A See Note (3). 330
Self Test 1 Status Integer*2 N/A 1 to 3 1 1=No, 2=OK, 3=Fail See Note(1) 331
Self Test 2 Status Integer*2 N/A 1 to 3 1 1=No, 2=OK, 3=Fail See Note(1) 332
Self Test 2 Data Integer*2 N/A N/A 1 Hex See Note (2) 333
Spare N/A N/A N/A N/A N/A See Note (3) 334 - 340
COHO/Clock Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 341
Rf Generator Frequency Select Oscillator Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 342
Rf Generator RF/STALO Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 343
Rf Generator Phase Shifted COHO Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 344
+9v Receiver PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 345
+5v Receiver PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 346
O/18v Receiver PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 347
-9v Receiver PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 348
+5v Single Channel RDAIU PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 349
Spare N/A N/A N/A N/A N/A See Note (3) 350
Horizontal Short Pulse Noise Real*4 dBm -100.00 to -50.00 0.01 N/A 351 - 352
Horizontal Long Pulse Noise Real*4 dBm -100.00 to -50.00 0.01 N/A 353 - 354
Horizontal Noise Temperature Real*4 K 0 to 9999.99 0.01 N/A 355 - 356
Vertical Noise Short Pulse N/A N/A N/A N/A N/A See Note (3) 357 - 358
Vertical Noise Long Pulse Real*4 dBm -100.00 to -50.00 0.01 N/A 359-360
Vertical Noise Temperature Real*4 K 0 to 9999.99 0.01 N/A 361-362
Horizontal Linearity Real*4 N/A 0.5000 to 1.5000 0.0001 N/A 363 - 364
Horizontal Dynamic Range Real*4 dB 0.000 to 120.000 0.001 N/A 365 - 366
Horizontal Delta dBZ0 Real*4 dB -198.00 to +198.00 0.01 N/A 367 - 368
Vertical Delta dBZ0 Real*4 dB -198.00 to +198.00 0.01 N/A 369 - 370
KD Peak Measured Real*4 dBm -99.90 to +99.90 0.01 N/A 371 - 372
Spare N/A N/A N/A N/A N/A See Note (3) 373 - 374
Short Pulse, Horizontal dBZ0 Real*4 dBZ -99.900 to +99.900 0.0001 N/A 375 - 376
Long Pulse, Horizontal dBZ0 Real*4 dBZ -99.9000 to +99.9000 0.0001 N/A 377 - 378
Velocity (Processed) Integer*2 N/A 0 to 1 1 0=Good, 1=Fail 379
Width (Processed) Integer*2 N/A 0 to 1 1 0=Good, 1=Fail 380
Velocity (RF Gen) Integer*2 N/A 0 to 1 1 0=Good, 1=Fail 381
Width (RF Gen) Integer*2 N/A 0 to 1 1 0=Good, 1=Fail 382
Horizontal I0 Real*4 dBm -999.9000 to +999.9000 0.0001 N/A 383 - 384
Vertical I0 Real*4 dBm -999.9000 to +999.9000 0.0001 N/A 385 - 386
Vertical Dynamic Range Real*4 dB 0.000 to 120.000 0.001 N/A 387 - 388
Short Pulse, Vertical dBZ0 Real*4 dBZ -99.9000 to +99.9000 0.0001 N/A 389 - 390
Long Pulse, Vertical dBZ0 Real*4 dBZ -99.9000 to +99.9000 0.0001 N/A 391 - 392
Spare N/A N/A N/A N/A N/A See Note (3) 393 - 394
Spare N/A N/A N/A N/A N/A See Note (3) 395 - 396
Horizontal Power Sense Real*4 dBm -999.9000 to +999.9000 0.0001 N/A 397 - 398
Vertical Power Sense Real*4 dBm -999.9000 to +999.9000 0.0001 N/A 399 - 400
ZDR Bias Real*4 dB -999.9000 to +999.9000 0.0001 N/A 401 - 402
Spare N/A N/A N/A N/A N/A See Note (3) 403 - 408
Clutter Suppression Delta Real*4 dB -99.90 to +99.90 0.01 N/A 409-410
Clutter Suppression Unfiltered Power Real*4 dBZ -99.90 to +99.90 0.01 N/A 411 - 412
Clutter Suppression Filtered Power Real*4 dBZ -99.90 to +99.90 0.01 N/A 413 - 414
Transmit Burst Power Real*4 dBm -99.90 to +99.90 0.01 N/A 415 - 416
Transmit Burst Phase Real*4 deg -99.00 to +99.90 0.01 N/A 417 - 418
Spare N/A N/A N/A N/A N/A See Note (3) 419 - 422
Spare N/A N/A N/A N/A N/A See Note (3) 423 - 424
Vertical Linearity Real*4 N/A 0.5000 to 1.5000 0.0001 N/A 425 - 426
Spare N/A N/A N/A N/A N/A See Note (3) 427 - 430
State File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 431
State File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 432
Bypass Map File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 433
Bypass Map File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 434
Spare N/A N/A N/A N/A N/A See Note (3) 435
Spare N/A N/A N/A N/A N/A See Note (3) 436
Current Adaptation File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 437
Current Adaptation File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 438
Censor Zone File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 439
Censor Zone File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 440
Remote VCP File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 441
Remote VCP File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 442
Baseline Adaptation File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 443
Spare N/A N/A N/A N/A N/A See Note (3) 444
Clutter Filter Map File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 445
Clutter Filter Map File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 446
General Disk I/O Error Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 447
Spare N/A N/A N/A N/A N/A See Note (3) 448 - 460
DAU Comm Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 461
HCI Comm Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 462
Pedestal Comm Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 463
Signal Processor Comm Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 464
AME Communication Status Integer*2 N/A 0 to 1 1 0 = OK 1 = FAIL 465
RMS Link Status Integer*2 N/A 0 to 1 1 0 = Connected, 1 = Not Connected 466
RPG Link Status Integer*2 N/A 0 to 1 1 0 = Connected, 1 = Not Connected 467
Spare N/A N/A N/A N/A N/A See Note (3) 468
Performance Check Time Integer*4 N/A N/A 1 469 - 470
Spare N/A N/A N/A N/A N/A See Note (3) 471 - 480
|