1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356
|
.. currentmodule:: pyb
.. _pyb.CAN:
class CAN -- controller area network communication bus
======================================================
CAN implements support for classic CAN (available on F4, F7 MCUs) and CAN FD (H7 series) controllers.
At the physical level CAN bus consists of 2 lines: RX and TX. Note that to connect the pyboard to a
CAN bus you must use a CAN transceiver to convert the CAN logic signals from the pyboard to the correct
voltage levels on the bus.
Example usage for classic CAN controller in Loopback (transceiver-less) mode::
from pyb import CAN
can = CAN(1, CAN.LOOPBACK)
can.setfilter(0, CAN.LIST16, 0, (123, 124, 125, 126)) # set a filter to receive messages with id=123, 124, 125 and 126
can.send('message!', 123) # send a message with id 123
can.recv(0) # receive message on FIFO 0
Example usage for CAN FD controller with all of the possible options enabled::
# FD frame + BRS mode + Extended frame ID. 500 Kbit/s for arbitration phase, 1Mbit/s for data phase.
can = CAN(1, CAN.NORMAL, baudrate=500_000, brs_baudrate=1_000_000, sample_point=80)
can.setfilter(0, CAN.RANGE, 0, (0xFFF0, 0xFFFF))
can.send('a'*64, 0xFFFF, fdf=True, brs=True, extframe=True)
can.recv(0)
The following CAN module functions and their arguments are available
for both classic and FD CAN controllers, unless otherwise stated.
Constructors
------------
.. class:: CAN(bus, ...)
Construct a CAN object on the given bus. *bus* can be 1-2, or ``'YA'`` or ``'YB'``.
With no additional parameters, the CAN object is created but not
initialised (it has the settings from the last initialisation of
the bus, if any). If extra arguments are given, the bus is initialised.
See :meth:`CAN.init` for parameters of initialisation.
The physical pins of the CAN buses are:
- ``CAN(1)`` is on ``YA``: ``(RX, TX) = (Y3, Y4) = (PB8, PB9)``
- ``CAN(2)`` is on ``YB``: ``(RX, TX) = (Y5, Y6) = (PB12, PB13)``
Methods
-------
.. method:: CAN.init(mode, prescaler=100, *, sjw=1, bs1=6, bs2=8, auto_restart=False, baudrate=0, sample_point=75,
num_filter_banks=14, brs_sjw=1, brs_bs1=8, brs_bs2=3, brs_baudrate=0, brs_sample_point=75)
Initialise the CAN bus with the given parameters:
- *mode* is one of: NORMAL, LOOPBACK, SILENT, SILENT_LOOPBACK
- *prescaler* is the value by which the CAN input clock is divided to generate the
nominal bit time quanta. The prescaler can be a value between 1 and 1024 inclusive
for classic CAN, and between 1 and 512 inclusive for CAN FD.
- *sjw* is the resynchronisation jump width in units of time quanta for nominal bits;
it can be a value between 1 and 4 inclusive for classic CAN, and between 1 and 128 inclusive for CAN FD.
- *bs1* defines the location of the sample point in units of the time quanta for nominal bits;
it can be a value between 1 and 16 inclusive for classic CAN, and between 2 and 256 inclusive for CAN FD.
- *bs2* defines the location of the transmit point in units of the time quanta for nominal bits;
it can be a value between 1 and 8 inclusive for classic CAN, and between 2 and 128 inclusive for CAN FD.
- *auto_restart* sets whether the controller will automatically try and restart
communications after entering the bus-off state; if this is disabled then
:meth:`~CAN.restart()` can be used to leave the bus-off state
- *baudrate* if a baudrate other than 0 is provided, this function will try to automatically
calculate the CAN nominal bit time (overriding *prescaler*, *bs1* and *bs2*) that satisfies
both the *baudrate* (within .1%) and the desired *sample_point* (to the nearest 1%). For more precise
control over the CAN timing, set the *prescaler*, *bs1* and *bs2* parameters directly.
- *sample_point* specifies the position of the bit sample with respect to the whole nominal bit time,
expressed as an integer percentage of the nominal bit time. The default *sample_point* is 75%.
This parameter is ignored unless *baudrate* is set.
- *num_filter_banks* for classic CAN, this is the number of banks that will be assigned to CAN(1),
the rest of the 28 are assigned to CAN(2).
The remaining parameters are only present on boards with CAN FD support, and configure the optional CAN FD
Bit Rate Switch (BRS) feature:
- *brs_prescaler* is the value by which the CAN FD input clock is divided to generate the
data bit time quanta. The prescaler can be a value between 1 and 32 inclusive.
- *brs_sjw* is the resynchronisation jump width in units of time quanta for data bits;
it can be a value between 1 and 16 inclusive
- *brs_bs1* defines the location of the sample point in units of the time quanta for data bits;
it can be a value between 1 and 32 inclusive
- *brs_bs2* defines the location of the transmit point in units of the time quanta for data bits;
it can be a value between 1 and 16 inclusive
- *brs_baudrate* if a baudrate other than 0 is provided, this function will try to automatically
calculate the CAN data bit time (overriding *brs_prescaler*, *brs_bs1* and *brs_bs2*) that satisfies
both the *brs_baudrate* (within .1%) and the desired *brs_sample_point* (to the nearest 1%). For more
precise control over the BRS timing, set the *brs_prescaler*, *brs_bs1* and *brs_bs2* parameters directly.
- *brs_sample_point* specifies the position of the bit sample with respect to the whole nominal bit time,
expressed as an integer percentage of the nominal bit time. The default *brs_sample_point* is 75%.
This parameter is ignored unless *brs_baudrate* is set.
The time quanta tq is the basic unit of time for the CAN bus. tq is the CAN
prescaler value divided by PCLK1 (the frequency of internal peripheral bus 1);
see :meth:`pyb.freq()` to determine PCLK1.
A single bit is made up of the synchronisation segment, which is always 1 tq.
Then follows bit segment 1, then bit segment 2. The sample point is after bit
segment 1 finishes. The transmit point is after bit segment 2 finishes.
The baud rate will be 1/bittime, where the bittime is 1 + BS1 + BS2 multiplied
by the time quanta tq.
For example, with PCLK1=42MHz, prescaler=100, sjw=1, bs1=6, bs2=8, the value of
tq is 2.38 microseconds. The bittime is 35.7 microseconds, and the baudrate
is 28kHz.
See page 680 of the STM32F405 datasheet for more details.
.. method:: CAN.deinit()
Turn off the CAN bus.
.. method:: CAN.restart()
Force a software restart of the CAN controller without resetting its
configuration.
If the controller enters the bus-off state then it will no longer participate
in bus activity. If the controller is not configured to automatically restart
(see :meth:`~CAN.init()`) then this method can be used to trigger a restart,
and the controller will follow the CAN protocol to leave the bus-off state and
go into the error active state.
.. method:: CAN.state()
Return the state of the controller. The return value can be one of:
- ``CAN.STOPPED`` -- the controller is completely off and reset;
- ``CAN.ERROR_ACTIVE`` -- the controller is on and in the Error Active state
(both TEC and REC are less than 96);
- ``CAN.ERROR_WARNING`` -- the controller is on and in the Error Warning state
(at least one of TEC or REC is 96 or greater);
- ``CAN.ERROR_PASSIVE`` -- the controller is on and in the Error Passive state
(at least one of TEC or REC is 128 or greater);
- ``CAN.BUS_OFF`` -- the controller is on but not participating in bus activity
(TEC overflowed beyond 255).
.. method:: CAN.info([list])
Get information about the controller's error states and TX and RX buffers.
If *list* is provided then it should be a list object with at least 8 entries,
which will be filled in with the information. Otherwise a new list will be
created and filled in. In both cases the return value of the method is the
populated list.
The values in the list are:
- TEC value
- REC value
- number of times the controller enterted the Error Warning state (wrapped
around to 0 after 65535)
- number of times the controller enterted the Error Passive state (wrapped
around to 0 after 65535)
- number of times the controller enterted the Bus Off state (wrapped
around to 0 after 65535)
- number of pending TX messages
- number of pending RX messages on fifo 0
- number of pending RX messages on fifo 1
.. method:: CAN.setfilter(bank, mode, fifo, params, *, rtr, extframe=False)
Configure a filter bank:
- *bank* is the classic CAN controller filter bank, or CAN FD filter index, to configure.
- *mode* is the mode the filter should operate in, see the tables below.
- *fifo* is which fifo (0 or 1) a message should be stored in, if it is accepted by this filter.
- *params* is an array of values the defines the filter. The contents of the array depends on the *mode* argument.
+-----------+---------------------------------------------------------+
|*mode* |Contents of *params* array for classic CAN controller |
+===========+=========================================================+
|CAN.LIST16 |Four 16 bit ids that will be accepted |
+-----------+---------------------------------------------------------+
|CAN.LIST32 |Two 32 bit ids that will be accepted |
+-----------+---------------------------------------------------------+
|CAN.MASK16 |Two 16 bit id/mask pairs. E.g. (1, 3, 4, 4) |
| | | The first pair, 1 and 3 will accept all ids |
| | | that have bit 0 = 1 and bit 1 = 0. |
| | | The second pair, 4 and 4, will accept all ids |
| | | that have bit 2 = 1. |
+-----------+---------------------------------------------------------+
|CAN.MASK32 |As with CAN.MASK16 but with only one 32 bit id/mask pair.|
+-----------+---------------------------------------------------------+
+-----------+---------------------------------------------------------+
|*mode* |Contents of *params* array for CAN FD controller |
+===========+=========================================================+
|CAN.RANGE |Two ids that represent a range of accepted ids. |
+-----------+---------------------------------------------------------+
|CAN.DUAL |Two ids that will be accepted. For example (1, 2) |
+-----------+---------------------------------------------------------+
|CAN.MASK |One filter ID and a mask. For example (0x111, 0x7FF) |
+-----------+---------------------------------------------------------+
- *rtr* For classic CAN controllers, this is an array of booleans that states if
a filter should accept a remote transmission request message. If this argument
is not given then it defaults to ``False`` for all entries. The length of the
array depends on the *mode* argument. For CAN FD, this argument is ignored.
+-----------+----------------------+
|*mode* |length of *rtr* array |
+===========+======================+
|CAN.LIST16 |4 |
+-----------+----------------------+
|CAN.LIST32 |2 |
+-----------+----------------------+
|CAN.MASK16 |2 |
+-----------+----------------------+
|CAN.MASK32 |1 |
+-----------+----------------------+
- *extframe* If True the frame will have an extended identifier (29 bits),
otherwise a standard identifier (11 bits) is used.
.. method:: CAN.clearfilter(bank, extframe=False)
Clear and disables a filter bank:
- *bank* is the classic CAN controller filter bank, or CAN FD filter index, to clear.
- *extframe* For CAN FD controllers, if True, clear an extended filter (configured with extframe=True),
otherwise the clear a standard identifier (configured with extframe=False).
.. method:: CAN.any(fifo)
Return ``True`` if any message waiting on the FIFO, else ``False``.
.. method:: CAN.recv(fifo, list=None, *, timeout=5000)
Receive data on the bus:
- *fifo* is an integer, which is the FIFO to receive on
- *list* is an optional list object to be used as the return value
- *timeout* is the timeout in milliseconds to wait for the receive.
Return value: A tuple containing five values.
- The id of the message.
- A boolean that indicates if the message ID is standard or extended.
- A boolean that indicates if the message is an RTR message.
- The FMI (Filter Match Index) value.
- An array containing the data.
If *list* is ``None`` then a new tuple will be allocated, as well as a new
bytes object to contain the data (as the fifth element in the tuple).
If *list* is not ``None`` then it should be a list object with a least five
elements. The fifth element should be a memoryview object which is created
from either a bytearray or an array of type 'B' or 'b', and this array must
have enough room for at least 8 bytes. The list object will then be
populated with the first four return values above, and the memoryview object
will be resized inplace to the size of the data and filled in with that data.
The same list and memoryview objects can be reused in subsequent calls to
this method, providing a way of receiving data without using the heap.
For example::
buf = bytearray(8)
lst = [0, 0, 0, 0, memoryview(buf)]
# No heap memory is allocated in the following call
can.recv(0, lst)
.. method:: CAN.send(data, id, *, timeout=0, rtr=False, extframe=False, fdf=False, brs=False)
Send a message on the bus:
- *data* is the data to send (an integer to send, or a buffer object).
- *id* is the id of the message to be sent.
- *timeout* is the timeout in milliseconds to wait for the send.
- *rtr* is a boolean that specifies if the message shall be sent as
a remote transmission request. If *rtr* is True then only the length
of *data* is used to fill in the DLC slot of the frame; the actual
bytes in *data* are unused.
- *extframe* if True the frame will have an extended identifier (29 bits),
otherwise a standard identifier (11 bits) is used.
- *fdf* for CAN FD controllers, if set to True, the frame will have an FD
frame format, which supports data payloads up to 64 bytes.
- *brs* for CAN FD controllers, if set to True, the bitrate switching mode
is enabled, in which the data phase is transmitted at a different bitrate.
See :meth:`CAN.init` for the data bit timing configuration parameters.
If timeout is 0 the message is placed in a buffer in one of three hardware
buffers and the method returns immediately. If all three buffers are in use
an exception is thrown. If timeout is not 0, the method waits until the
message is transmitted. If the message can't be transmitted within the
specified time an exception is thrown.
Return value: ``None``.
.. method:: CAN.rxcallback(fifo, fun)
Register a function to be called when a message is accepted into a empty fifo:
- *fifo* is the receiving fifo.
- *fun* is the function to be called when the fifo becomes non empty.
The callback function takes two arguments the first is the can object it self the second is
a integer that indicates the reason for the callback.
+--------+------------------------------------------------+
| Reason | |
+========+================================================+
| 0 | A message has been accepted into a empty FIFO. |
+--------+------------------------------------------------+
| 1 | The FIFO is full |
+--------+------------------------------------------------+
| 2 | A message has been lost due to a full FIFO |
+--------+------------------------------------------------+
Example use of rxcallback::
def cb0(bus, reason):
print('cb0')
if reason == 0:
print('pending')
if reason == 1:
print('full')
if reason == 2:
print('overflow')
can = CAN(1, CAN.LOOPBACK)
can.rxcallback(0, cb0)
Constants
---------
.. data:: CAN.NORMAL
CAN.LOOPBACK
CAN.SILENT
CAN.SILENT_LOOPBACK
The mode of the CAN bus used in :meth:`~CAN.init()`.
.. data:: CAN.STOPPED
CAN.ERROR_ACTIVE
CAN.ERROR_WARNING
CAN.ERROR_PASSIVE
CAN.BUS_OFF
Possible states of the CAN controller returned from :meth:`~CAN.state()`.
.. data:: CAN.LIST16
CAN.MASK16
CAN.LIST32
CAN.MASK32
The operation mode of a filter used in :meth:`~CAN.setfilter()` for classic CAN.
.. data:: CAN.DUAL
CAN.RANGE
CAN.MASK