File: ld.html

package info (click to toggle)
nec 2-9
  • links: PTS
  • area: main
  • in suites: sarge
  • size: 1,444 kB
  • ctags: 3,102
  • sloc: fortran: 16,377; makefile: 126; sh: 10
file content (132 lines) | stat: -rw-r--r-- 6,621 bytes parent folder | download | duplicates (3)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
<!-- X-URL: http://www.members.home.net/nec2/part_3/cards/ld.html -->
<BASE HREF="http://www.members.home.net/nec2/part_3/cards/ld.html">

<!DOCTYPE HTML SYSTEM "html.dtd">
<html><head><title>Loading (LD)</title></head>
<body>

<H2><center>Loading (LD)</center></h2>
<u><b>
Purpose:</b></u> To specify the impedance loading on one segment or a number of
         segments.  Series and parallel RLC circuits can be generated.  In
         addition, a finite conductivity can be specified for segments.
<p>
<u><b>Card:</b></u>
<pre> 
     _________________________________________________________________
    /2|  5|   10|   15|   20|    30|    40|    50|    60|    70|    80|
   /  |   |     |     |     |      |      |      |      |      |      |
  |   |   |     |     |     |      |      |      |      |      |      |
  |LD |I1 | I2  | I3  | I4  |  F1  |  F2  |  F3  |  F4  |  F5  |  F6  |
  |   |   |     |     |     |      |      |      |      |      |      |
  |   | L |  L  |  L  | L   | ZLR  | ZLI  | ZLI  |  B   |  B   |  B   |
  |   | D |  D  |  D  | D   |      |      |      |  L   |  L   |  L   |
  |   | T |  T  |  T  | T   |      |      |      |  A   |  A   |  A   |
  |   | Y |  A  |  A  | A   |      |      |      |  N   |  N   |  N   |
  |   | P |  G  |  G  | G   |      |      |      |  K   |  K   |  K   |
  |   |   |     |  F  | T   |      |      |      |      |      |      |
  |  The numbers along the top refer to the last column in each field |
  |   |   |     |     |     |      |      |      |      |      |      |

</PRE>
<dl>
<dt><u><b>Parameters:</b></u>
<dl><dt><b>Integers</b>
<dl><dt><u>LDTYP (I1)</u> -  Determines the type of loading which is used.  The
                   options are:
<dd> -1 - short all loads (used to nullify previous loads).  The remainder of the card is left
blank.
<dd>0 - series RLC, input ohms, henries, farads.
<dd>1 - parallel RLC, input ohms, henries, farads.
<dd>2 - series RLC, input ohms/meter, henries/meter, farads/meter.
<dd>3 - parallel RLC, input ohms/meter, henries/meter, farads/meter.
<dd>4 - impedance, input resistance and reactance in ohms.
<dd>5 - wire conductivity, mhos/meter.
<p>
<dt><u>LDTAG (I2)</u>    Tag number; identifies the wire section(s) to be
                   loaded by its (their) tag numbers.  The next two
                   parameters can be used to further specify certain
                   segment(s) on the wire section(s).  Blank or zero
                   here implies that absolute segment numbers are being
                   used in the next two parameters to identify segments.
                   If the next two paramters ara blank or zero, all
                   segments with tag LDTAG are loaded.
<p>
<dt><u>LDTAGF (13)</u> - Equal to m specifies the mth segment of the set of
                   segments whose tag numbers equal the tag number
                   specified in the previous parameter.  If the previous
                   parameter (LDTAG) is zero, LDTAGF then specifies an
                   absolute segment number.  If both LDTAG and LDTAGF
                   are zero, all segments will be loaded.
<p>
<dt><u>LDTAGT (14)</u> - Equal to n specifies the nth segment of the set of
                   segments whose tag numbers equal the tag number
                   specified in the parameter LDTAG.  This parameter
                   must be greater than or equal to the previous param-
                   eter.  The loading specified is applied to each of
                   the mth through nth segments of the set of segments
                   having tags equal to LDTAG.  Again if LDTAG is zero,
                   these parameters refer to absolute segment numbers.
                   If LDTAGT is left blank, it is set equal to the
                   previous parameter (LDTAGF).
</dl>
</dl>
<dl><dt><b>Floating Point</b> Input for the Various Load Types
<dd><dl><dt>a. Series <a href="../gifs/rlc1.gif">RLC </a> (LDTYP = 0)
<dd>ZLR (Fl) - Resistance in ohms, if none, leave blank.
<dd>ZLI (F2) - Inductance in henries, if none, leave blank.
<dd>ZLC (F3) - Capacitance in farads, if none, leave blank.
</dl>
<dd>b. Parallel <a href="../gifs/rlc2.gif">RLC</a> (LDTYP = 1), floating point input same as a.

<dd><dl><dt>c. Series <a href="../gifs/rlc1.gif"> RLC</a> (LDTYP = 2) input, parameters per unit length.
<dd>                 ZLR - Resistance in ohms/meter, if none, leave blank.
<dd>                 ZLI - Inductance in henries/meter, if none, leave blank.
<dd>                 ZLC - Capacitance in farads/meter, if none, leave blank.
</dl>
<dd>d. Parallel <a href="../gifs/rlc2.gif">RLC</a>RLC (LDTYP = 3), input parameters per unit length,
                 floating point input same as c.
<p>
<dd><dl><dt> e. Impedance (LDTYP = 4)
<dd>                 ZLR - Resistance in ohms.
<dd>                 ZLI - Reactance in ohms.
</dl>

<dd><dl><dt>f. Wire conductivity (LDTYP = 5)
<dd>ZLR - Conductivity in mhos/meter.
</dl>
</dl>
</dl>
<ul>
<lh><b>Notes:</b></lh>
<li>Loading cards can be input in groups to achieve a desired structure
loading.  The maximum number of loading cards in a group is determined
by dimensions in the program.  The limit is presently 30.
<li>If a segment is loaded more than once by a group of loading cards,
the loads are assumed to be in series (impedances added), and a
comment is printed in the output alerting the user to this fact.
<li>When resistance and reactance are input (LDTYP = 4), the impedance
does not automatically scale with frequency.
<li>Loading cards used after any form of execute, require the regeneration
of the structure matrix.
<li>Since loading modifies the interaction matrix, it will affect the
conditions of plane or cylindrical symmetry of a structure.  If a
structure is geometrically symmetric and each symmetric section is to
receive identical loading, then symmetry may be used in the solution.
The program is set to utilize symmetry during geometry input by
inputting the data for one symmetric section and completing the
structure with a GR or GX card.  If symmetry is used, the loading on
only the first symmetric section is input on LD cards. The same
loading will be assumed on the other sections. Loading should not
be specified for segments beyond the first section when symmetry is
used. If the sections are not identically loaded, then during
geometry input the program must be set to a no-symmetry condition to
permit independent loading of corresponding segments in different
sections.