1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392
|
.. _hoc_oldgrph:
Obsolete Plotting
-----------------
.. hoc:function:: graphmode
obsolete. see :hoc:func:`graph`. Use :hoc:class:`Graph`.
----
.. hoc:function:: graph
Name:
graph --- multiple line plots
Syntax:
``graph()``
``graph(expression, setup)``
``graph(t)``
``graphmode(mode)``
Description:
``Graph()`` solves the problem of obtaining multiple line plots during
a single run. During calls to ``graph(t)``, specified variables are stored
and plotted using scales determined by calls to ``axis()``.
Options:
``graph()``
erases the old list and starts a new (empty)
list of plot expressions and setup statements.
``graph(s1, s2)``
Adds a new plot specification
to the graph list. s1 must be
string which contains an expression, usually a variable. e.g "y". s2 is a
string which contains any number of statements used to initialize axes. etc.
E.G "``axis(0,5,1,-1,1,2) axis()``".
``graph(t)``
The current value of each
expression in the graph list is saved along with the abscissa value, t.
The line plots are flushed every 50 points.
``graphmode(1)``
Executes the list of setup statements.
This is also done on the
first call to ``graph(t)`` after
a new setup statement is added to the list.
``graphmode(-1)``
Flushes the stored plots. Subsequent calls to
``graph(t)`` will start new lines.
Should be executed just before a ``plt(-1)`` to ensure the entire lines
are plotted.
``graphmode(2)``
Flushes the stored plots. Subsequent calls to
``graph(t)`` will continue the lines.
Graphs are normally flushed every 50 points.
Example:
.. code-block::
none
proc p() { /* plot ramp */
axis(100,300,450,200)
axis(0,15,3,-1,1,2)
axis()
plot(1)
for (x=0; x<15; x=x+.1) {
plot(x, x/15) /* ramp */
graph(x) /* plots graph list if any */
}
graph(-1) /* flush remaining part of graphs, if any */
plt(-1)
}
p() /*plots the ramp alone*/
graph()
graph("sin(x)","axis(100,300,100,300) axis()")
graph("cos(x)","") /* same axes as previous call to graph */
p() /* plots the sin and cos along with the ramp */
Diagnostics:
The strings are parsed when ``graph(s1, s2)`` is executed. The strings are
executed on calls to ``graph(t)``.
The best method for complicated plots is to make the setup string a
simple call to a user defined procedure. This procedure can setup the
axes, write the labels, etc. Newlines and strings within strings are
possible by quoting with the '\verb+\+' character but generally are
too confusing to be practical.
Local variables in graph strings make no sense.
.. seealso::
:hoc:func:`plot`
----
.. hoc:function:: axis
See :hoc:func:`plot`
----
.. hoc:function:: plotx
----
.. hoc:function:: ploty
----
.. hoc:function:: regraph
See :hoc:func:`graph`
----
.. hoc:function:: plot
Name:
plot, axis - plot relative to scale given by axes
Syntax:
``axis(args)``
``plot(mode)``
``inrange = plot(x,y)``
Description:
``Plot()`` plots relative to the origin and scale defined by
calls to axis. The default x and y axes have relative units of 0 to 1 with the plot
located in a 5x3.5 inch area.
Options:
``plot()``
print parameter usage help lines.
``plot(0)``
subsequent calls will plot points.
``plot(1)``
next call will be a move, subsequent call will draw lines.
``plot(x, y)``
plots a point (or vector) relative to the axis scale.
Return value is 0 if the point is clipped (out of range).
``plot(mode, x, y)``
Like ``plt()`` but with scale and origin given by axis().
``axis()``
draw axes with label values. Closes plot device.
``axis(clip)``
points are not plotted if they are a factor clip off the axis scale.
Default is no clipping. Set clip to 1 to not plot out of axis region.
A value of 1.1 allows plotting slightly outside the axis boundaries.
``axis(xorg, xsize, yorg, ysize)``
Size and location of the plot region.
(Use the plt() absolute coordinates.)
``axis(xstart, xstop, nticx, ystart, ystop, nticy)``
Determines relative scale and origin.
Specification of the precision of axis tic labels is available by
recompiling :file:`hoc/SRC/plot.c` with ``#define Jaslove 1+``. With this definition,
the number of tics specified in the 3rd and 6th arguments of ``axis()`` should
be of the form m.n. m is the number of tic marks, and n is the number of
digits after the decimal point which are printed. This contribution was
made by Stewart Jaslove.
Example:
.. code-block::
none
proc plotsin() { /* plot the sin function from 0 to 10 radians */
axis(0, 10, 5, -1, 1, 2) /* setup scale */
plot(1)
for (x=0; x<=10; x=x+.1) {
plot(x, sin(x)) /* plot the function */
}
axis() /* draw the axes */
}
.. seealso::
:hoc:func:`plt`, :hoc:func:`setcolor`, :hoc:func:`axis`
----
.. hoc:function:: setcolor
obsolete. See :hoc:func:`plt`.
----
.. hoc:function:: settext
obsolete. See :hoc:func:`plt`.
----
.. hoc:function:: plt
Name:
plt, setcolor- low level plot functions
Syntax:
``plt(mode)``
``plt(mode, x, y)``
``setcolor(colorval)``
Description:
\ ``Plt()`` plots points, lines, and text using
the Tektronix 4010 standard. Absolute
coordinates of the lower left corner and upper right corner of the plot
region are (0,0) and (1000, 780) respectively.
\ ``Setcolor()`` sets the color (or pen number for HP plotter)
TURBO-C graphics drivers for VGA, EGA, CGA, and Hercules are automatically
selected when the first plotting command is executed. An HP7475 compatible
plotter may be connected to COM1:.
Options:
\ ``plt(-1)``
Place cursor in home position.
\ ``plt(-2)``
Subsequent text printed starting at current coordinate position.
\ ``plt(-3)``
Erase screen, cursor in home position.
\ ``plt(-5)``
Open HP plotter on PC.
\ ``setcolor()``
The plotter will stay open till another \ ``plt(-5)`` is executed.
\ ``plt(0, x, y)``
Plot point.
\ ``plt(1, x, y)``
Move to point without plotting.
\ ``plt(2, x, y)``
Draw vector from former position to new position given by (x,y).
(*mode* can be any number >= 2)
Several extra options are available for X11 graphics.
\ ``plt(-4, x, y)``
Erases area defined by previous plot position and
the point, (x, y).
\ ``plt(-5)``
Fast mode. By default, the X11 server is flushed on every
plot command so one can see the plot as it develops. Fast mode caches plot
commands and only flushes on \ ``plt(-1)`` and \ ``setcolor()``. Fast mode is
three times faster than the default mode. It is most useful when
plotting is the rate limiting step of the simulation.
\ ``plt(-6)``
X11 server flushed on every plot call.
When the graphic window is resized, hoc is notified after
the next erase command.
Argument to \ ``setcolor()`` produces the following screen
colors with an EGA adapter, X11 graphics:
.. code-block::
none
0 black (pen 1 on HP plotter) black
1 blue white
2 green yellow
3 cyan red
4 red green
5 magenta blue
6 brown violet
7 light gray (pen 1 on HP plotter) cyan
...
15 white green
Example:
.. code-block::
none
proc plotsin() { /* This procedure plots the sin function in red.*/
setcolor(4)
plt(1, 100, 500) plt(2, 100, 100) /* y-axis*/
plt(1, 100, 300) plt(2, 600, 300) /* x-axis*/
plt(1, 200, 550)
plt(-2) print "SIN(x) from 0 to 2*PI" /* label*/
for(i=0; i<=100;i=i+1){
plt(i+1, i*500/100, 300 + 200*sin(2*PI*i/100))
}
plt(-1) /* close plot */
}
.. seealso::
:hoc:func:`plot`, :hoc:func:`axis`, :hoc:func:`lw`
.. warning::
EGA adaptor used extensively but CGA and Hercules used hardly at all.
When the X11 graphic window is killed, hoc exits without asking about