File: sec.h

package info (click to toggle)
nut 0.45.5-rel-1
  • links: PTS
  • area: main
  • in suites: woody
  • size: 1,984 kB
  • ctags: 2,146
  • sloc: ansic: 22,216; sh: 1,138; makefile: 405
file content (265 lines) | stat: -rw-r--r-- 15,783 bytes parent folder | download
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
/*                               -*- Mode: C -*- 
 * sec.h -- header for sec protocol module
 * 
 * Copyright (C) 2000 John Marley
 * The author can be contacted at: John.Marley@alcatel.com.au
 * 
 * Author          : John Marley
 * Created On      : Thu Mar 29 11:07:01 2001
 * Last Modified By: John Marley
 * Last Modified On: Fri May  4 16:26:00 2001
 * Update Count    : 53
 * Status          : Unknown, Use with caution!
 * $Locker:  $
 * $Log: sec.h,v $
 * Revision 1.2  2001/05/08 03:21:09  marleyj
 * Added supported() macro.
 *
 * Revision 1.1  2001/05/02 04:54:33  marleyj
 * Initial revision
 *
 */

#define SEC_MSG_STARTCHAR	'^'
#define SEC_POLLCMD		'P'
#define SEC_SETCMD		'S'
#define SEC_DATAMSG		'D'
#define SEC_UPSMSG		'*'
#define SEC_ACK			'1'
#define SEC_NAK			'0'

/* commands */
#define SEC_AVAILP1	"AP1"		/* Part1 of available variables */
#define SEC_AVAILP2	"AP2"		/* Part1 of available variables */
#define SEC_AUTORESTART	"ATR"		/* Enable/disable auto restart */
#define SEC_MFR		"MAN"		/* UPS Manufacturer */
#define SEC_MOD		"MOD"		/* UPS Model */
#define SEC_NOMINAL	"NOM"		/* Nominal Values */
#define SEC_SHUTDOWN	"PSD"		/* Shutdown after delay/cancel */
#define SEC_REBOOT	"RWD"		/* Reboot with duration/cancel */
#define SEC_SHUTTYPE	"SDA"		/* Shutdown Type */
#define SEC_BATTSTAT	"ST1"		/* Battery Status */
#define SEC_INPUTSTAT	"ST2"		/* Input Status */
#define SEC_OUTPUTSTAT	"ST3"		/* Output Status */
#define SEC_BYPASSSTAT	"ST4"		/* Bypass Status */
#define SEC_ALARMSTAT	"ST5"		/* UPS Alarms */
#define SEC_STARTDELAY	"STD"		/* Startup after delay */
#define SEC_TESTRESULT	"STR"		/* Test Results */
#define SEC_TEST	"TST"		/* UPS Test/abort */
#define SEC_BAUDRATE	"UBR"		/* UPS Baud Rate */
#define SEC_UPSID	"UID"		/* UPS Identifier */
#define SEC_VERSION	"VER"		/* UPS Software Version */

/* Some baud rates for setup_serial() */
struct baud_rate_t {
    int rate;
    int name;
} baud_rates[] = {
    { B1200,  1200 },
    { B2400,  2400 },
    { B4800,  4800 },
    { B9600,  9600 },
    { B19200, 19200 },
};

/*
 * Exhaustive information for each possible variable
 */
#define SEC_NUMVARS 89
#define SEC_MAX_VARSIZE 65

/* macro for checking whether a variable is supported */
#define supported(v)	(getdata(v) != NULL)

struct sec_varlist_t {
    int  infotag;	/* INFO_x define from shared.h */
    char *name;		/* Human readable text (also in shared-tables.h) */
    int  unit;		/* Variable should be divided by this */
    char *cmd;		/* Command to send to pool/set variable */
    int  field;		/* Which returned field variable corresponsd to */
    int  size;		/* string length/integer max/enum count */
    int  edi;		/* 'E'numerated 'D'ata 'I'ndex */
    int  flags;		/* Flags for addinfo() */
    char value[SEC_MAX_VARSIZE];
} sec_varlist[] = {
    { INFO_UNUSED,          "",                          0, "",              0,       0,  0, 0 },
    /*infotag               name                      unit  cmd          field     size edi  flags */
    { INFO_ALRM_PWRWAIT,    "Alarm Awaiting Power",      1, SEC_ALARMSTAT,  13,       2,  0, FLAG_ENUM },
    { INFO_ALRM_BADBYPASS,  "Alarm Bypass Bad",          1, SEC_ALARMSTAT,   5,       2,  2, FLAG_ENUM },
    { INFO_ALRM_CHARGFAIL,  "Alarm Charger Failure",     1, SEC_ALARMSTAT,   8,       2,  4, FLAG_ENUM },
    { INFO_ALRM_FANFAIL,    "Alarm Fan Failure",         1, SEC_ALARMSTAT,  10,       2,  6, FLAG_ENUM },
    { INFO_ALRM_FUSEFAIL,   "Alarm Fuse Failure",        1, SEC_ALARMSTAT,  11,       2,  8, FLAG_ENUM },
    { INFO_ALRM_GENERAL,    "Alarm General Fault",       1, SEC_ALARMSTAT,  12,       2, 10, FLAG_ENUM },
    { INFO_ALRM_BADINPUT,   "Alarm Input Bad",           1, SEC_ALARMSTAT,   2,       2, 12, FLAG_ENUM },
    { INFO_ALRM_BADOUTPUT,  "Alarm Output Bad",          1, SEC_ALARMSTAT,   3,       2, 14, FLAG_ENUM },
    { INFO_ALRM_OUTPUTOFF,  "Alarm Output Off",          1, SEC_ALARMSTAT,   6,       2, 16, FLAG_ENUM },
    { INFO_ALRM_OVERLOAD,   "Alarm Overload",            1, SEC_ALARMSTAT,   4,       2, 18, FLAG_ENUM },
    { INFO_ALRM_IMMSHUT,    "Alarm Shutdown Imminent",   1, SEC_ALARMSTAT,  15,       2, 20, FLAG_ENUM },
    { INFO_ALRM_PENDSHUT,   "Alarm Shutdown Pending",    1, SEC_ALARMSTAT,  14,       2, 22, FLAG_ENUM },
    { INFO_ALRM_SYSOFF,     "Alarm System Off",          1, SEC_ALARMSTAT,   9,       2, 24, FLAG_ENUM },
    { INFO_ALRM_TEMP,       "Alarm Temperature",         1, SEC_ALARMSTAT,   1,       2, 26, FLAG_ENUM },
    { INFO_ALRM_UPSSHUT,    "Alarm UPS Shutdown",        1, SEC_ALARMSTAT,   7,       2, 28, FLAG_ENUM },
    { INFO_AUDIBLEALRM,     "Audible Alarm",             1, SEC_NOMINAL,     8,       4, 29, FLAG_ENUM | FLAG_RW },
    { INFO_AUTORESTART,     "Auto Restart",              1, SEC_AUTORESTART, 1,       2, 33, FLAG_ENUM | FLAG_RW },
    { INFO_BATT_CHARGE,     "Battery Charge",            1, SEC_BATTSTAT,    3,       4, 36, FLAG_ENUM },
    { INFO_BATT_COND,       "Battery Condition",         1, SEC_BATTSTAT,    1,       3, 40, FLAG_ENUM },
    { INFO_BATT_CURRENT,    "Battery Current",          10, SEC_BATTSTAT,    8,    9999,  0, 0 },
    { INFO_BATT_DATE,       "Battery Installed",         1, SEC_NOMINAL,    11,       8,  0, FLAG_STRING | FLAG_RW },
    { INFO_BATT_STATUS,     "Battery Status",            1, SEC_BATTSTAT,    2,       3, 43, FLAG_ENUM },
    { INFO_BATT_TEMP,       "Battery Temperature",       1, SEC_BATTSTAT,    9,      99,  0, 0 },
    { INFO_BATT_VOLT,	    "Battery Voltage",          10, SEC_BATTSTAT,    7,    9999,  0, 0 },
    { INFO_BYPASS_CURRENT1, "Bypass Current 1",         10, SEC_BYPASSSTAT,  4,    9999,  0, 0 },
    { INFO_BYPASS_CURRENT2, "Bypass Current 2",         10, SEC_BYPASSSTAT,  7,    9999,  0, 0 },
    { INFO_BYPASS_CURRENT3, "Bypass Current 3",         10, SEC_BYPASSSTAT, 10,    9999,  0, 0 },
    { INFO_BYPASS_FREQ,     "Bypass Frequency",         10, SEC_BYPASSSTAT,  1,     999,  0, 0 },
    { INFO_BYPASS_NLINES,   "Bypass Num Lines",          1, SEC_BYPASSSTAT,  2,       9,  0, 0 },
    { INFO_BYPASS_PWR1,     "Bypass Power 1",            1, SEC_BYPASSSTAT,  5,   99999,  0, 0 },
    { INFO_BYPASS_PWR2,     "Bypass Power 2",            1, SEC_BYPASSSTAT,  8,   99999,  0, 0 },
    { INFO_BYPASS_PWR3,     "Bypass Power 3",            1, SEC_BYPASSSTAT, 11,   99999,  0, 0 },
    { INFO_BYPASS_VOLT1,    "Bypass Voltage 1",         10, SEC_BYPASSSTAT,  3,    9999,  0, 0 },
    { INFO_BYPASS_VOLT2,    "Bypass Voltage 2",         10, SEC_BYPASSSTAT,  6,    9999,  0, 0 },
    { INFO_BYPASS_VOLT3,    "Bypass Voltage 3",         10, SEC_BYPASSSTAT,  9,    9999,  0, 0 },
    { INFO_BATT_PCT,        "Estimated Charge",          1, SEC_BATTSTAT,    6,     999,  0, 0 },
    { INFO_RUNTIME,         "Estimated Minutes",         1, SEC_BATTSTAT,    5,     999,  0, 0 },
    { INFO_HIGHXFER,        "High Volt Xfer Pt",         1, SEC_NOMINAL,    10,     999,  0, FLAG_STRING | FLAG_RW },
    { INFO_UPSIDENT,        "Identification",            1, SEC_UPSID,       1,      64,  0, FLAG_STRING | FLAG_RW },
    { INFO_IN_CURRENT1,     "Input Current 1",          10, SEC_INPUTSTAT,   5,    9999,  0, 0 },
    { INFO_IN_CURRENT2,     "Input Current 2",          10, SEC_INPUTSTAT,   9,    9999,  0, 0 },
    { INFO_IN_CURRENT3,     "Input Current 3",          10, SEC_INPUTSTAT,  13,    9999,  0, 0 },
    { INFO_IN_ACFREQ1,      "Input Frequency 1",        10, SEC_INPUTSTAT,   3,     999,  0, 0 },
    { INFO_IN_ACFREQ2,      "Input Frequency 2",        10, SEC_INPUTSTAT,   7,     999,  0, 0 },
    { INFO_IN_ACFREQ3,      "Input Frequency 3",        10, SEC_INPUTSTAT,  11,     999,  0, 0 },
    { INFO_IN_LINEBADS,     "Input Line Bads",           1, SEC_INPUTSTAT,   1,     999,  0, 0 },
    { INFO_IN_NLINES,       "Input Num Lines",           1, SEC_INPUTSTAT,   2,       9,  0, 0 },
    { INFO_IN_PWR1,         "Input Power 1",             1, SEC_INPUTSTAT,   6,   99999,  0, 0 },
    { INFO_IN_PWR2,         "Input Power 2",             1, SEC_INPUTSTAT,  10,   99999,  0, 0 },
    { INFO_IN_PWR3,         "Input Power 3",             1, SEC_INPUTSTAT,  14,   99999,  0, 0 },
    { INFO_IN_VOLT1,        "Input Voltage 1",          10, SEC_INPUTSTAT,   4,    9999,  0, 0 },
    { INFO_IN_VOLT2,        "Input Voltage 2",          10, SEC_INPUTSTAT,   8,    9999,  0, 0 },
    { INFO_IN_VOLT3,        "Input Voltage 3",          10, SEC_INPUTSTAT,  12,    9999,  0, 0 },
    { INFO_LOWXFER,         "Low Volt Xfer Pt",          1, SEC_NOMINAL,     9,     999,  0, FLAG_STRING | FLAG_RW },
    { INFO_MFR,             "Manufacturer",              1, SEC_MFR,         1,      32,  0, FLAG_STRING },
    { INFO_MODEL,           "Model",                     1, SEC_MOD,         1,      64,  0, FLAG_STRING },
    { INFO_NOM_BATTLIFE,    "Nominal Battery Life",      1, SEC_NOMINAL,    12,   99999,  0, FLAG_STRING | FLAG_RW },
    { INFO_NOM_IN_FREQ,     "Nominal Input Frequency",  10, SEC_NOMINAL,     2,     999,  0, FLAG_RW },
    { INFO_NOM_IN_VOLT,     "Nominal Input Voltage",     1, SEC_NOMINAL,     1,     999,  0, FLAG_STRING | FLAG_RW },
    { INFO_NOM_LOBATTIME,   "Nominal Low Battery Time",  1, SEC_NOMINAL,     7,      99,  0, FLAG_STRING | FLAG_RW },
    { INFO_NOM_OUT_FREQ,    "Nominal Output Frequency", 10, SEC_NOMINAL,     4,     999,  0, FLAG_RW },
    { INFO_NOM_OUT_PWR,     "Nominal Output Power",      1, SEC_NOMINAL,     6,   99999,  0, FLAG_STRING | FLAG_RW },
    { INFO_NOM_OUT_VOLT,    "Nominal Output Voltage",    1, SEC_NOMINAL,     3,     999,  0, FLAG_STRING | FLAG_RW },
    { INFO_NOM_VA_RATE,     "Nominal VA Rating",         1, SEC_NOMINAL,     5,   99999,  0, FLAG_STRING | FLAG_RW },
    { INFO_OUT_CURRENT1,    "Output Current 1",         10, SEC_OUTPUTSTAT,  5,    9999,  0, 0 },
    { INFO_OUT_CURRENT2,    "Output Current 2",         10, SEC_OUTPUTSTAT,  9,    9999,  0, 0 },
    { INFO_OUT_CURRENT3,    "Output Current 3",         10, SEC_OUTPUTSTAT, 13,    9999,  0, 0 },
    { INFO_OUT_FREQ,        "Output Frequency",         10, SEC_OUTPUTSTAT,  2,     999,  0, 0 },
    { INFO_OUT_LOADPCT1,    "Output Load 1",             1, SEC_OUTPUTSTAT,  7,     999,  0, 0 },
    { INFO_OUT_LOADPCT2,    "Output Load 2",             1, SEC_OUTPUTSTAT, 11,     999,  0, 0 },
    { INFO_OUT_LOADPCT3,    "Output Load 3",             1, SEC_OUTPUTSTAT, 15,     999,  0, 0 },
    { INFO_OUT_NLINES,      "Output Num Lines",          1, SEC_OUTPUTSTAT,  3,       9,  0, 0 },
    { INFO_OUT_LOADPWR1,    "Output Power 1",            1, SEC_OUTPUTSTAT,  6,   99999,  0, 0 },
    { INFO_OUT_LOADPWR2,    "Output Power 2",            1, SEC_OUTPUTSTAT, 10,   99999,  0, 0 },
    { INFO_OUT_LOADPWR3,    "Output Power 3",            1, SEC_OUTPUTSTAT, 14,   99999,  0, 0 },
    { INFO_OUT_SOURCE,      "Output Source",             1, SEC_OUTPUTSTAT,  1,       6, 46, FLAG_ENUM },
    { INFO_OUT_VOLT1,       "Output Voltage 1",         10, SEC_OUTPUTSTAT,  4,    9999,  0, 0 },
    { INFO_OUT_VOLT2,       "Output Voltage 2",         10, SEC_OUTPUTSTAT,  8,    9999,  0, 0 },
    { INFO_OUT_VOLT3,       "Output Voltage 3",         10, SEC_OUTPUTSTAT, 12,    9999,  0, 0 },
    { INFO_RBTWDUR,         "Reboot With Duration",      1, SEC_REBOOT,      1, 9999999,  0, FLAG_WONLY },
    { INFO_SECSONBATT,      "Seconds on Battery",        1, SEC_BATTSTAT,    4,   99999,  0, 0 },
    { INFO_SHUTTYPE,        "Shutdown Type",             1, SEC_SHUTTYPE,    1,       2, 51, FLAG_ENUM | FLAG_RW },
    { INFO_DELAYSHUT,       "Shutdown After Delay",      1, SEC_STARTDELAY,  1, 9999999,  0, FLAG_WONLY },
    { INFO_FIRMREV,         "Software Version",          1, SEC_VERSION,     1,      32,  0, FLAG_STRING },
    { INFO_WAKEDELAY,       "Startup After Delay",       1, SEC_STARTDELAY,  1, 9999999,  0, FLAG_WONLY },
    { INFO_SLFTSTDETAIL,    "Test Results Detail",       1, SEC_TESTRESULT,  2,      64,  0, FLAG_STRING },
    { INFO_SLFTSTSUM,       "Test Results Summary",      1, SEC_TESTRESULT,  1,       6, 54, FLAG_ENUM },
    { INFO_SLFTSTTYPE,      "Test Type",                 1, SEC_TEST,        1,       5, 61, FLAG_ENUM | FLAG_WONLY },
    { INFO_BAUDRATE,        "Baud Rate",                 1, SEC_BAUDRATE,    1,   19200,  0, FLAG_RW },
};


/*
 * List of possible enumerations
 */

struct sec_enumdata_t {
    int type;		/* INFO_x type */
    int index;		/* ups value */
    const char *value;	/* enumerated value */
} sec_enumdata[] = {
    { INFO_ALRM_PWRWAIT,	0, "Not Awaiting Power" },
    { INFO_ALRM_PWRWAIT,	1, "Awaiting Power" },
    { INFO_ALRM_BADBYPASS,	0, "Bypass OK" },
    { INFO_ALRM_BADBYPASS,	1, "Bypass Fault" },
    { INFO_ALRM_CHARGFAIL,	0, "Charger OK" },
    { INFO_ALRM_CHARGFAIL,	1, "Charger Fault" },
    { INFO_ALRM_FANFAIL,	0, "Fan OK" },
    { INFO_ALRM_FANFAIL,	1, "Fan Fault" },
    { INFO_ALRM_FUSEFAIL,	0, "Fuse OK" },
    { INFO_ALRM_FUSEFAIL,	1, "Fuse Fault" },
    { INFO_ALRM_GENERAL,	0, "General system OK" },
    { INFO_ALRM_GENERAL,	1, "General system Fault" },
    { INFO_ALRM_BADINPUT,	0, "Input OK" },
    { INFO_ALRM_BADINPUT,	1, "Input Fault" },
    { INFO_ALRM_BADOUTPUT,	0, "Output OK" },
    { INFO_ALRM_BADOUTPUT,	1, "Output Fault" },
    { INFO_ALRM_OUTPUTOFF,	0, "Output On" },
    { INFO_ALRM_OUTPUTOFF,	1, "Output off" },
    { INFO_ALRM_OVERLOAD,	0, "UPS not overloaded" },
    { INFO_ALRM_OVERLOAD,	1, "UPS Overloaded" },
    { INFO_ALRM_IMMSHUT,	0, "No Shutdown Imminent" },
    { INFO_ALRM_IMMSHUT,	1, "Shutdown Imminent" },
    { INFO_ALRM_PENDSHUT,	0, "No Shutdown Pending" },
    { INFO_ALRM_PENDSHUT,	1, "Shutdown Pending" },
    { INFO_ALRM_SYSOFF,		0, "System On" },
    { INFO_ALRM_SYSOFF,		1, "System off" },
    { INFO_ALRM_TEMP,		0, "Temperature OK" },
    { INFO_ALRM_TEMP,		1, "Over Temperature" },
    { INFO_ALRM_UPSSHUT,	0, "UPS not Shutdown" },
    { INFO_ALRM_UPSSHUT,	1, "UPS Shutdown" },
    { INFO_AUDIBLEALRM,		1, "Disabled" },
    { INFO_AUDIBLEALRM,		2, "Enabled" },
    { INFO_AUDIBLEALRM,		3, "Muted" },
    { INFO_AUDIBLEALRM,		4, "Disabled Until Low Battery warning" },
    { INFO_AUTORESTART,		1, "Automatic Restart" },
    { INFO_AUTORESTART,		2, "Manual Restart" },
    { INFO_BATT_CHARGE,		0, "Floating" },
    { INFO_BATT_CHARGE,		1, "Charging" },
    { INFO_BATT_CHARGE,		2, "Resting" },
    { INFO_BATT_CHARGE,		3, "Discharging" },
    { INFO_BATT_COND,		0, "Good" },
    { INFO_BATT_COND,		1, "Weak" },
    { INFO_BATT_COND,		2, "Replace" },
    { INFO_BATT_STATUS,		0, "Battery OK" },
    { INFO_BATT_STATUS,		1, "Battery Low" },
    { INFO_BATT_STATUS,		2, "Battery Depleted" },
    { INFO_OUT_SOURCE,		0, "Normal" },
    { INFO_OUT_SOURCE,		1, "On Battery" },
    { INFO_OUT_SOURCE,		2, "On Bypass" },
    { INFO_OUT_SOURCE,		3, "Reducing" },
    { INFO_OUT_SOURCE,		4, "Boosting" },
    { INFO_OUT_SOURCE,		5, "Other" },
    { INFO_SHUTTYPE,		1, "UPS output only" },
    { INFO_SHUTTYPE,		2, "Entire UPS" },
    { INFO_SLFTSTSUM,		0, "No test performed" },
    { INFO_SLFTSTSUM,		1, "Test Passed" },
    { INFO_SLFTSTSUM,		2, "Test in progress" },
    { INFO_SLFTSTSUM,		3, "General Test failed" },
    { INFO_SLFTSTSUM,		4, "Battery Test failed" },
    { INFO_SLFTSTSUM,		5, "Deep Battery Test failed" },
    { INFO_SLFTSTTYPE,		-1, "Abort test in progress" },
    { INFO_SLFTSTTYPE,		0, "No test" },
    { INFO_SLFTSTTYPE,		1, "General Systems Test" },
    { INFO_SLFTSTTYPE,		2, "Quick Battery Test" },
    { INFO_SLFTSTTYPE,		3, "Deep Battery Calibration" },
};


/* a type for the supported variables */
#define SEC_QUERYLIST_LEN	17
#define SEC_MAXFIELDS		16

struct sec_querylist_t {
    char *command;	/* sec command */
    int  varnum[SEC_MAXFIELDS];	/* sec variable number for each field */
} sec_querylist[SEC_QUERYLIST_LEN];

#define sqv(a,b) sec_querylist[a].varnum[b]