1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161
|
/* apcsmart_tabs.c - common tables for APC smart protocol units
*
* Copyright (C) 1999 Russell Kroll <rkroll@exploits.org>
* (C) 2000 Nigel Metheringham <Nigel.Metheringham@Intechnology.co.uk>
* (C) 2011+ Michal Soltys <soltys@ziu.info>
*
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; either version 2 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, write to the Free Software
* Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
*/
#include "apcsmart_tabs.h"
/* APC_MULTI variables *must* be listed in order of preference */
apc_vartab_t apc_vartab[] = {
{ "ups.temperature", 'C', APC_POLL|APC_F_CELSIUS },
{ "ups.load", 'P', APC_POLL|APC_F_PERCENT },
{ "ups.test.interval", 'E', APC_F_HOURS },
{ "ups.test.result", 'X', APC_POLL },
{ "ups.delay.start", 'r', APC_F_SECONDS },
{ "ups.delay.shutdown", 'p', APC_F_SECONDS },
{ "ups.id", 'c', APC_STRING },
{ "ups.contacts", 'i', APC_POLL|APC_F_HEX },
{ "ups.display.language", '\014' },
{ "input.voltage", 'L', APC_POLL|APC_F_VOLT },
{ "input.frequency", 'F', APC_POLL|APC_F_DEC },
{ "input.sensitivity", 's', },
{ "input.quality", '9', APC_POLL|APC_F_HEX },
{ "input.transfer.low", 'l', APC_F_VOLT },
{ "input.transfer.high", 'u', APC_F_VOLT },
{ "input.transfer.reason", 'G', APC_POLL|APC_F_REASON },
{ "input.voltage.maximum", 'M', APC_POLL|APC_F_VOLT },
{ "input.voltage.minimum", 'N', APC_POLL|APC_F_VOLT },
{ "output.current", '/', APC_POLL|APC_F_AMP },
{ "output.voltage", 'O', APC_POLL|APC_F_VOLT },
{ "output.voltage.nominal", 'o', APC_F_VOLT },
{ "ambient.humidity", 'h', APC_POLL|APC_F_PERCENT },
{ "ambient.0.humidity", 'H', APC_POLL|APC_PACK|APC_F_PERCENT },
{ "ambient.0.humidity.high", '{', APC_POLL|APC_PACK|APC_F_PERCENT },
{ "ambient.0.humidity.low", '}', APC_POLL|APC_PACK|APC_F_PERCENT },
{ "ambient.temperature", 't', APC_POLL|APC_F_CELSIUS },
{ "ambient.0.temperature", 'T', APC_MULTI|APC_POLL|APC_PACK|APC_F_CELSIUS, "^[0-9]{2}\\.[0-9]{2}$" },
{ "ambient.0.temperature.high", '[', APC_POLL|APC_PACK|APC_F_CELSIUS },
{ "ambient.0.temperature.low", ']', APC_POLL|APC_PACK|APC_F_CELSIUS },
{ "battery.date", 'x', APC_STRING },
{ "battery.charge", 'f', APC_POLL|APC_F_PERCENT },
{ "battery.charge.restart", 'e', APC_F_PERCENT },
{ "battery.voltage", 'B', APC_POLL|APC_F_VOLT },
{ "battery.voltage.nominal", 'g', },
{ "battery.runtime", 'j', APC_POLL|APC_F_MINUTES },
{ "battery.runtime.low", 'q', APC_F_MINUTES },
{ "battery.packs", '>', APC_F_DEC },
{ "battery.packs.bad", '<', APC_F_DEC },
{ "battery.alarm.threshold", 'k', },
{ "device.uptime", 'T', APC_MULTI|APC_POLL|APC_F_HOURS, "^[0-9]{3}\\.[0-9]{1}$" },
{ "ups.serial", 'n', },
{ "ups.mfr.date", 'm', },
{ "ups.model", '\001' },
{ "ups.firmware.aux", 'v', },
{ "ups.firmware", 'b', APC_MULTI, "^[[:alnum:]]+\\.[[:alnum:]]+\\.[[:alnum:]]+$" },
{ "ups.firmware", 'V', APC_MULTI },
{ NULL }
/* todo:
I = alarm enable (hex field) - split into alarm.n.enable
J = alarm status (hex field) - split into alarm.n.status
0x15 = output voltage selection (APC_F_VOLT)
0x5C = load power (APC_POLL|APC_F_PERCENT)
*/
};
/*
* APC commands mapped to NUT's instant commands
* the format of extra values is matched by extended posix regex
* APC_CMD_CUSTOM means that the instant command is handled by separate
* function, thus the actual APC cmd in the table is ignored
*/
apc_cmdtab_t apc_cmdtab[] = {
{ "shutdown.return", "^[Aa][Tt]:[0-9]{1,3}$",
APC_CMD_GRACEDOWN, APC_NASTY },
{ "shutdown.return", "^([Cc][Ss]|)$",
APC_CMD_SOFTDOWN, APC_NASTY },
{ "shutdown.stayoff", 0, APC_CMD_SHUTDOWN, APC_NASTY|APC_REPEAT },
{ "load.off", 0, APC_CMD_OFF, APC_NASTY|APC_REPEAT },
{ "load.on", 0, APC_CMD_ON, APC_REPEAT },
{ "calibrate.start", 0, APC_CMD_CALTOGGLE, 0 },
{ "calibrate.stop", 0, APC_CMD_CALTOGGLE, 0 },
{ "test.panel.start", 0, APC_CMD_FPTEST, 0 },
{ "test.failure.start", 0, APC_CMD_SIMPWF, 0 },
{ "test.battery.start", 0, APC_CMD_BTESTTOGGLE, 0 },
{ "test.battery.stop", 0, APC_CMD_BTESTTOGGLE, 0 },
{ "bypass.start", 0, APC_CMD_BYPTOGGLE, 0 },
{ "bypass.stop", 0, APC_CMD_BYPTOGGLE, 0 },
{ NULL }
};
/* compatibility with hardware that doesn't do APC_CMDSET ('a') */
apc_compattab_t apc_compattab[] = {
/* APC Matrix */
{ "0XI", "@789ABCDEFGKLMNOPQRSTUVWXYZcefgjklmnopqrsuwxz/<>\\^\014\026", 0 },
{ "0XM", "@789ABCDEFGKLMNOPQRSTUVWXYZcefgjklmnopqrsuwxz/<>\\^\014\026", 0 },
{ "0ZI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz/<>", 0 },
{ "5UI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz/<>", 0 },
{ "5ZM", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz/<>", 0 },
/* APC600 */
{ "6QD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
{ "6QI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
{ "6TD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
{ "6TI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
/* SmartUPS 900 */
{ "7QD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
{ "7QI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
{ "7TD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
{ "7TI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
/* SmartUPS 600I */
{ "6JI", "@789ABCFGKLMNOPQSTUVWXYZfg", 0 },
/* SmartUPS 900I */
{ "7II", "@79ABCEFGKLMNOPQRSUVWXYZcfg", 0 },
/* SmartUPS 2000I */
{ "9II", "@79ABCEFGKLMNOPQRSUVWXYZcfg", 0 },
{ "9GI", "@79ABCEFGKLMNOPQRSUVWXYZcfg", 0 },
/* SmartUPS 1250I */
{ "8II", "@79ABCEFGKLMNOPQRSUVWXYZcfg", 0 },
{ "8GI", "@79ABCEFGKLMNOPQRSUVWXYZfg", 0 },
/* SmartUPS 1250 */
{ "8QD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
{ "8QI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
{ "8TD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
{ "8TI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
/* CS 350 */
{ "5.4.D", "@\1ABPQRSUYbdfgjmnx9", 0 },
/*
* certain set of UPSes returning voltage > 255V through 'b'; "set\1"
* is matched explicitly (fake key); among the UPS models - some old
* APC 600 ones
*/
{ "set\1", "@789ABCFGKLMNOPQRSUVWXYZ", 0 },
{ NULL }
};
upsdrv_info_t apc_tab_info = {
"APC command table",
APC_TABLE_VERSION
};
|