File: upscli_disconnect.3

package info (click to toggle)
nut 2.8.1-5
  • links: PTS, VCS
  • area: main
  • in suites: trixie
  • size: 18,284 kB
  • sloc: ansic: 108,785; sh: 9,370; cpp: 3,370; makefile: 2,842; python: 1,029; perl: 763; xml: 47
file content (53 lines) | stat: -rw-r--r-- 2,069 bytes parent folder | download
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
'\" t
.\"     Title: upscli_disconnect
.\"    Author: [FIXME: author] [see http://www.docbook.org/tdg5/en/html/author]
.\" Generator: DocBook XSL Stylesheets vsnapshot <http://docbook.sf.net/>
.\"      Date: 10/31/2023
.\"    Manual: NUT Manual
.\"    Source: Network UPS Tools 2.8.1
.\"  Language: English
.\"
.TH "UPSCLI_DISCONNECT" "3" "10/31/2023" "Network UPS Tools 2\&.8\&.1" "NUT Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.\" http://bugs.debian.org/507673
.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.ie \n(.g .ds Aq \(aq
.el       .ds Aq '
.\" -----------------------------------------------------------------
.\" * set default formatting
.\" -----------------------------------------------------------------
.\" disable hyphenation
.nh
.\" disable justification (adjust text to left margin only)
.ad l
.\" -----------------------------------------------------------------
.\" * MAIN CONTENT STARTS HERE *
.\" -----------------------------------------------------------------
.SH "NAME"
upscli_disconnect \- disconnect from a UPS server
.SH "SYNOPSIS"
.sp
.nf
#include <upsclient\&.h>
.fi
.sp
.nf
int upscli_disconnect(UPSCONN_t *ups);
.fi
.SH "DESCRIPTION"
.sp
The \fBupscli_disconnect()\fR function takes the pointer \fIups\fR to a UPSCONN_t state structure, shuts down the connection to the server, and frees dynamic memory used by the state structure\&.
.sp
The UPSCONN_t structure is no longer valid after this function is called\&.
.sp
This function must be called, or your program will leak memory and file descriptors\&.
.SH "RETURN VALUE"
.sp
The \fBupscli_disconnect()\fR function returns 0 on success, or \-1 if an error occurs\&.
.SH "SEE ALSO"
.sp
\fBupscli_connect\fR(3), \fBupscli_fd\fR(3), \fBupscli_strerror\fR(3), \fBupscli_upserror\fR(3)