1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260
|
Desc: APC UPS cables
File: apc.txt
Date: 12 February 2010
Auth: Arjen de Korte <adkorte-guest@alioth.debian.org
http://lists.alioth.debian.org/pipermail/nut-upsuser/2005-August/000118.html
Note that APC UPS serial cable part numbers follow a numbering scheme
where the "940-" prefix identifies them as cables.
940-1000 straight through cable
940-0103 null modem cable
940-0020 Basic Signaling Cable (OB and kill power)
940-0023 Simple Signaling Cable (OB only)
940-LL24 Smart Signaling Cable
940-0095 PnP Cable (see Apcupsd manual for diagram)
940-0119 Simple Signaling Cable (OB and kill power)
940-0127 RJ45-10P10C to USB Cable
940-0128 Simple Signaling Cable for Back-UPS CS
"LL" represents the length:
00 six feet
NN NN feet
The suffix letter represents a minor revision in physical design, or a
change of OEM, _not_ a change of wiring or pin-out, and all cables
differing only in this suffix letter are electrically interchangeable.
Note though the following quote from the APC Discussion Forums: "At one
point there were a small number of revision D cables [940-0024D] that
had some shielding issues from the manufacturer that could maybe cause
[...] [spontaneous] self-tests)."
+-----------------------------------------------------------------+
| |
| Black APC 940-0024C Smart Signalling UPS Cable Wiring Diagram |
| This information is verified and tested to be 100% correct. |
| |
+-----------------------------------------------------------------+
| |
| DB9M(UPS) 2m Cable DB9F(Computer) |
| --------- -------- -------------- |
| |
| (SHELL)<---------+----//----+----------------<(SHELL) |
| | | |
| - - |
| | | | | |
| CHASSIS 9<--------------//---------------------<5 SG |
| | | | | |
| TXD 2<--------------//---------------------<2 RXD |
| | | | | |
| RXD 1<--------------//---------------------<3 TXD |
| | | | | |
| - - +--<1 DCD |
| | |
| +--<4 DTR |
| NOTES: |
| Cable type is shielded 28AWG. +--<7 RTS |
| The DB shells are connected | |
| to each other via the shield. +--<8 CTS |
| |
+-----------------------------------------------------------------+
| |
| Operation: The UPS communicates with the Computer via |
| ordinary RS-232 serial protocol at 2400-8N1 with software |
| flow control. Jumpered pins in the DB9F connector are for |
| automatic or PNP cable identification by UPS software. |
| |
+-----------------------------------------------------------------+
| |
| Male (pins) Female (holes) |
| DB9 RS-232 PC |
| type connector 1 5 5 1 |
| ---------------- _______________ _______________ |
| Pinout numbering \ . . . . . / \ o o o o o / |
| looking into the \ . . . . / \ o o o o / |
| end of the cable ----------- ----------- |
| 6 9 9 6 |
| |
| NOTE: Solder a wire to the metal shell for use as a FRAME-GND |
| |
+-----------------------------------------------------------------+
+-----------------------------------------------------------------+
| |
| Gray APC 940-0020B Simple Signalling UPS Cable Wiring Diagram |
| This information is verified and tested to be 100% correct. |
| |
+-----------------------------------------------------------------+
| |
| DB9M(UPS) 2m Cable DB9F(Computer) |
| --------- -------- -------------- |
| |
| (SHELL)<-------+----//----+-------------------<(SHELL) |
| | | |
| CHASSIS 9<--+ - - |
| | | | | | |
| COMMON 4<--+---------//------------------------<5 SG |
| | | | | |
| POWER-FAIL 2<------------//------------------------<8 CTS |
| | | | | |
| SHUTDOWN 1<------------//------------------------<4 DTR |
| | | | | |
| BATTERY-LOW 5<------------//--------47K--+--47K--+--<7 RTS |
| | | | | | | |
| - - | E | |
| NOTES: |B |<--+ |
| RTS must be held at +V SPACE. +---| |
| TXD must be held at -V MARK. 2N3906 |---+--<1 DCD |
| All resistors are 5% 1/8W CF. C | |
| Cable type is shielded 28AWG. 4K7 |
| The DB shells are connected | |
| to each other via the shield. +--<3 TXD |
| |
+-----------------------------------------------------------------+
| |
| Operation: The UPS communicates with the Computer via |
| the RS-232 handshaking lines only, and does not use any |
| serial protocol. Upon power fail, the UPS forces CTS to |
| -V MARK. When the battery is low, the UPS forces DCD to |
| +V SPACE via the transistor. When the Computer forces a |
| +V SPACE on DTR, the UPS will shut down and turn off. |
| Presence of the cable can be sensed by signaling on TXD |
| while monitoring DCD. |
| |
+-----------------------------------------------------------------+
| |
| Male (pins) Female (holes) |
| DB9 RS-232 PC |
| type connector 1 5 5 1 |
| ---------------- _______________ _______________ |
| Pinout numbering \ . . . . . / \ o o o o o / |
| looking into the \ . . . . / \ o o o o / |
| end of the cable ----------- ----------- |
| 6 9 9 6 |
| |
| NOTE: Solder a wire to the metal shell for use as a FRAME-GND |
| |
+-----------------------------------------------------------------+
+-----------------------------------------------------------------+
| |
| Gray APC 940-0095A Smart Signalling UPS Cable Wiring Diagram |
| This information is verified and tested to be 100% correct. |
| |
+-----------------------------------------------------------------+
| |
| DB9M(UPS) 2m Cable DB9F(Computer) |
| --------- -------- -------------- |
| |
| (SHELL)<-------+----//----+--------------------<(SHELL) |
| | | |
| CHASSIS 9<--+ - - |
| | | | | | |
| COMMON 4<--+---------//-------------------------<5 SG |
| | | | | |
| BATTERY-LOW 5<------------//--------47K--+--47K--+---<4 DTR |
| | | | | | | |
| | +---<6 DSR |
| | | | | | E | |
| NOTES: |B |<--+---<8 CTS |
| DTR must be held at +V SPACE. | | +---| |
| TXD must be held at -V MARK. 2N3906 |---+---<1 DCD |
| All resistors are 5% 1/8W CF. | | C | |
| Cable type is shielded 28AWG. 4K7 |
| The DB shells are connected | | | |
| to each other via the shield. +----4K7---+---<3 TXD |
| | | | | | |
| | |
| | | | | | 1N4148 |
| SHUTDOWN 1<------------//----------+----|<|-------<7 RTS |
| | | | | K A |
| POWER-FAIL 2<------------//---------------------+---<2 RXD |
| | | | | | |
| - - +---<9 RI |
| |
+-----------------------------------------------------------------+
| |
| Operation: The UPS can communicate with the Computer |
| solely via the RS-232 handshaking lines, or via RS-232 |
| serial protocol at 2400-8N1 with software flow control. |
| Upon power fail, the UPS forces RI to -V MARK. When the |
| battery is low, the UPS forces DCD to +V SPACE via the |
| transistor. When the Computer forces a +V SPACE on RTS, |
| the UPS will shut down and turn off. Jumpered pins in |
| the DB9F connector allow for automatic automatic or PNP |
| cable identification by UPS software. |
| |
+-----------------------------------------------------------------+
| |
| Male (pins) Female (holes) |
| DB9 RS-232 PC |
| type connector 1 5 5 1 |
| ---------------- _______________ _______________ |
| Pinout numbering \ . . . . . / \ o o o o o / |
| looking into the \ . . . . / \ o o o o / |
| end of the cable ----------- ----------- |
| 6 9 9 6 |
| |
| NOTE: Solder a wire to the metal shell for use as a FRAME-GND |
| |
+-----------------------------------------------------------------+
+-----------------------------------------------------------------+
| |
| APC 940-1000 Straight Through cable |
| Universal APC serial extension cable for use in conjunction |
| with an APC UPS cable. This cable is verified to work. |
| |
+-----------------------------------------------------------------+
| |
| DB9M to UPS cable Shielded Cable DB9F to Computer |
| ----------------- --- 28AWG ---- ---------------- |
| |
| (SHELL)<----+-------------//-------------+----<(SHELL) |
| | | |
| - - |
| | | | | |
| 1<------------------//------------------<1 DCD |
| | | | | |
| 2<------------------//------------------<2 RXD |
| | | | | |
| 3<------------------//------------------<3 TXD |
| | | | | |
| 4<------------------//------------------<4 DTR |
| | | | | |
| 5<------------------//------------------<5 SG |
| | | | | |
| 6<------------------//------------------<6 DSR |
| | | | | |
| 7<------------------//------------------<7 RTS |
| | | | | |
| 8<------------------//------------------<8 CTS |
| | | | | |
| 9<------------------//------------------<9 RI |
| | | | | |
| - - |
| NOTE: The DB shells are connected to each other via the shield. |
| |
+-----------------------------------------------------------------+
| |
| Male (pins) Female (holes) |
| DB9 RS-232 PC |
| type connector 1 5 5 1 |
| ---------------- _______________ _______________ |
| Pinout numbering \ . . . . . / \ o o o o o / |
| looking into the \ . . . . / \ o o o o / |
| end of the cable ----------- ----------- |
| 6 9 9 6 |
| |
| NOTE: Solder a wire to the metal shell for use as a FRAME-GND |
| |
+-----------------------------------------------------------------+
|