1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218
|
'\" t
.\" Title: upscode2
.\" Author: [see the "AUTHORS" section]
.\" Generator: DocBook XSL Stylesheets vsnapshot <http://docbook.sf.net/>
.\" Date: 08/08/2025
.\" Manual: NUT Manual
.\" Source: Network UPS Tools 2.8.4
.\" Language: English
.\"
.TH "UPSCODE2" "8" "08/08/2025" "Network UPS Tools 2\&.8\&.4" "NUT Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.\" http://bugs.debian.org/507673
.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.ie \n(.g .ds Aq \(aq
.el .ds Aq '
.\" -----------------------------------------------------------------
.\" * set default formatting
.\" -----------------------------------------------------------------
.\" disable hyphenation
.nh
.\" disable justification (adjust text to left margin only)
.ad l
.\" -----------------------------------------------------------------
.\" * MAIN CONTENT STARTS HERE *
.\" -----------------------------------------------------------------
.SH "NAME"
upscode2 \- Driver for UPScode II compatible UPS equipment
.SH "SYNOPSIS"
.sp
\fBupscode2\fR \-h
.sp
\fBupscode2\fR \-a \fIUPS_NAME\fR [\fIOPTIONS\fR]
.if n \{\
.sp
.\}
.RS 4
.it 1 an-trap
.nr an-no-space-flag 1
.nr an-break-flag 1
.br
.ps +1
\fBNote\fR
.ps -1
.br
.sp
This man page only documents the hardware\-specific features of the upscode2 driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&.
.sp .5v
.RE
.SH "SUPPORTED HARDWARE"
.sp
This driver supports UPS equipment which can be controlled via the UPScode II protocol\&. This is mainly Fiskars, Powerware equipment, but also some (probably OEM\(cqed) products from Compaq\&.
.SH "EXTRA ARGUMENTS"
.sp
This driver supports the following optional settings in the \fBups.conf\fR(5):
.PP
\fBmanufacturer\fR=\fIvalue\fR
.RS 4
Autodetection of this parameter is not possible yet (and it probably never will be)\&. Therefore, this user\-defined string accepts any name\&. The default is
\fIunknown\fR\&.
.RE
.PP
\fBinput_timeout\fR=\fIvalue\fR
.RS 4
The timeout waiting for a response from the UPS\&. Some UPS models have shown to be rather slow, resulting in frequent messages about empty responses from the UPS\&. If you see this, try increasing this value\&.
.RE
.PP
\fBoutput_pace\fR=\fIvalue\fR
.RS 4
Delay between characters sent to the UPS\&. This was added for completeness with the above parameter\&. It has not shown to be needed yet\&.
.RE
.PP
\fBbaudrate\fR=\fIvalue\fR
.RS 4
The default baudrate is 1200, which is the standard for the UPScode II protocol\&.
.RE
.PP
\fBfull_update_timer\fR=\fIvalue\fR
.RS 4
Number of seconds between collection of normative values\&.
.RE
.PP
\fBuse_crlf\fR
.RS 4
Flag to set if commands towards to UPS need to be terminated with CR\-LF, and not just CR\&.
.RE
.PP
\fBuse_pre_lf\fR
.RS 4
Flag to set if commands towards to UPS need to be introduced with an LF\&. A Compaq T1500h is known to need this\&.
.RE
.SH "COMMANDS"
.sp
The driver supports the following commands for those UPSes that support them\&. The available commands are autodetected during initialization, so you should check availability with \fIupscmd \-l\fR\&.
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
test\&.panel\&.start \- Start UPS self test
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
test\&.battery\&.start \- Start battery self test
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
beeper\&.enable \- Enable UPS beeper
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
beeper\&.disable \- Disable UPS beeper
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
shutdown\&.return \- Shut down in 1 second and wait for power to return
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
shutdown\&.stayoff \- Shut down in 1 seconds
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
shutdown\&.reboot \- Shut down in 1 seconds and reboot after 1 minute
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
shutdown\&.reboot\&.graceful \- Shut down in 20 seconds and reboot after 1 minute
.RE
.SH "NOTES"
.sp
The Powerware UPS models that this driver has been tested against until now have not returned a value for \fIbattery\&.charge\fR\&. Therefore, the driver will guesstimate a value based on the nominal battery min/max and the current battery voltage\&.
.SH "AUTHORS"
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
HÃ¥vard Lygre <hklygre@online\&.no>
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Niels Baggesen <niels@baggesen\&.net>
.RE
.SH "SEE ALSO"
.SS "The core driver:"
.sp
\fBnutupsdrv\fR(8)
.SS "Internet resources:"
.sp
The NUT (Network UPS Tools) home page: https://www\&.networkupstools\&.org/historic/v2\&.8\&.4/
|