1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331
|
/* This work is licensed under a Creative Commons CCZero 1.0 Universal License.
* See http://creativecommons.org/publicdomain/zero/1.0/ for more information. */
#include <open62541/plugin/log_stdout.h>
#include <open62541/server.h>
/**
* Working with Objects and Object Types
* -------------------------------------
*
* Using objects to structure information models
* ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
* Assume a situation where we want to model a set of pumps and their runtime
* state in an OPC UA information model. Of course, all pump representations
* should follow the same basic structure, For example, we might have graphical
* representation of pumps in a SCADA visualisation that shall be resuable for
* all pumps.
*
* Following the object-oriented programming paradigm, every pump is represented
* by an object with the following layout:
*
* .. graphviz::
*
* digraph tree {
*
* fixedsize=true;
* node [width=2, height=0, shape=box, fillcolor="#E5E5E5", concentrate=true]
*
* node_root [label=< <I>ObjectNode</I><BR/>Pump >]
*
* { rank=same
* point_1 [shape=point]
* node_1 [label=< <I>VariableNode</I><BR/>ManufacturerName >] }
* node_root -> point_1 [arrowhead=none]
* point_1 -> node_1 [label="hasComponent"]
*
* { rank=same
* point_2 [shape=point]
* node_2 [label=< <I>VariableNode</I><BR/>ModelName >] }
* point_1 -> point_2 [arrowhead=none]
* point_2 -> node_2 [label="hasComponent"]
*
* { rank=same
* point_4 [shape=point]
* node_4 [label=< <I>VariableNode</I><BR/>Status >] }
* point_2 -> point_4 [arrowhead=none]
* point_4 -> node_4 [label="hasComponent"]
*
* { rank=same
* point_5 [shape=point]
* node_5 [label=< <I>VariableNode</I><BR/>MotorRPM >] }
* point_4 -> point_5 [arrowhead=none]
* point_5 -> node_5 [label="hasComponent"]
*
* }
*
* The following code manually defines a pump and its member variables. We omit
* setting constraints on the variable values as this is not the focus of this
* tutorial and was already covered. */
static void
manuallyDefinePump(UA_Server *server) {
UA_NodeId pumpId; /* get the nodeid assigned by the server */
UA_ObjectAttributes oAttr = UA_ObjectAttributes_default;
oAttr.displayName = UA_LOCALIZEDTEXT("en-US", "Pump (Manual)");
UA_Server_addObjectNode(server, UA_NODEID_NULL,
UA_NODEID_NUMERIC(0, UA_NS0ID_OBJECTSFOLDER),
UA_NODEID_NUMERIC(0, UA_NS0ID_ORGANIZES),
UA_QUALIFIEDNAME(1, "Pump (Manual)"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEOBJECTTYPE),
oAttr, NULL, &pumpId);
UA_VariableAttributes mnAttr = UA_VariableAttributes_default;
UA_String manufacturerName = UA_STRING("Pump King Ltd.");
UA_Variant_setScalar(&mnAttr.value, &manufacturerName, &UA_TYPES[UA_TYPES_STRING]);
mnAttr.displayName = UA_LOCALIZEDTEXT("en-US", "ManufacturerName");
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "ManufacturerName"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
mnAttr, NULL, NULL);
UA_VariableAttributes modelAttr = UA_VariableAttributes_default;
UA_String modelName = UA_STRING("Mega Pump 3000");
UA_Variant_setScalar(&modelAttr.value, &modelName, &UA_TYPES[UA_TYPES_STRING]);
modelAttr.displayName = UA_LOCALIZEDTEXT("en-US", "ModelName");
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "ModelName"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
modelAttr, NULL, NULL);
UA_VariableAttributes statusAttr = UA_VariableAttributes_default;
UA_Boolean status = true;
UA_Variant_setScalar(&statusAttr.value, &status, &UA_TYPES[UA_TYPES_BOOLEAN]);
statusAttr.displayName = UA_LOCALIZEDTEXT("en-US", "Status");
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "Status"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
statusAttr, NULL, NULL);
UA_VariableAttributes rpmAttr = UA_VariableAttributes_default;
UA_Double rpm = 50.0;
UA_Variant_setScalar(&rpmAttr.value, &rpm, &UA_TYPES[UA_TYPES_DOUBLE]);
rpmAttr.displayName = UA_LOCALIZEDTEXT("en-US", "MotorRPM");
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "MotorRPMs"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
rpmAttr, NULL, NULL);
}
/**
* Object types, type hierarchies and instantiation
* ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
* Building up each object manually requires us to write a lot of code.
* Furthermore, there is no way for clients to detect that an object represents
* a pump. (We might use naming conventions or similar to detect pumps. But
* that's not exactly a clean solution.) Furthermore, we might have more devices
* than just pumps. And we require all devices to share some common structure.
* The solution is to define ObjectTypes in a hierarchy with inheritance
* relations.
*
* .. graphviz::
*
* digraph tree {
*
* fixedsize=true;
* node [width=2, height=0, shape=box, fillcolor="#E5E5E5", concentrate=true]
*
* node_root [label=< <I>ObjectTypeNode</I><BR/>Device >]
*
* { rank=same
* point_1 [shape=point]
* node_1 [label=< <I>VariableNode</I><BR/>ManufacturerName<BR/>(mandatory) >] }
* node_root -> point_1 [arrowhead=none]
* point_1 -> node_1 [label="hasComponent"]
*
* { rank=same
* point_2 [shape=point]
* node_2 [label=< <I>VariableNode</I><BR/>ModelName >] }
* point_1 -> point_2 [arrowhead=none]
* point_2 -> node_2 [label="hasComponent"]
*
* { rank=same
* point_3 [shape=point]
* node_3 [label=< <I>ObjectTypeNode</I><BR/>Pump >] }
* point_2 -> point_3 [arrowhead=none]
* point_3 -> node_3 [label="hasSubtype"]
*
* { rank=same
* point_4 [shape=point]
* node_4 [label=< <I>VariableNode</I><BR/>Status<BR/>(mandatory) >] }
* node_3 -> point_4 [arrowhead=none]
* point_4 -> node_4 [label="hasComponent"]
*
* { rank=same
* point_5 [shape=point]
* node_5 [label=< <I>VariableNode</I><BR/>MotorRPM >] }
* point_4 -> point_5 [arrowhead=none]
* point_5 -> node_5 [label="hasComponent"]
*
* }
*
* Children that are marked mandatory are automatically instantiated together
* with the parent object. This is indicated by a `hasModellingRule` reference
* to an object that representes the `mandatory` modelling rule. */
/* predefined identifier for later use */
UA_NodeId pumpTypeId = {1, UA_NODEIDTYPE_NUMERIC, {1001}};
static void
defineObjectTypes(UA_Server *server) {
/* Define the object type for "Device" */
UA_NodeId deviceTypeId; /* get the nodeid assigned by the server */
UA_ObjectTypeAttributes dtAttr = UA_ObjectTypeAttributes_default;
dtAttr.displayName = UA_LOCALIZEDTEXT("en-US", "DeviceType");
UA_Server_addObjectTypeNode(server, UA_NODEID_NULL,
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEOBJECTTYPE),
UA_NODEID_NUMERIC(0, UA_NS0ID_HASSUBTYPE),
UA_QUALIFIEDNAME(1, "DeviceType"), dtAttr,
NULL, &deviceTypeId);
UA_VariableAttributes mnAttr = UA_VariableAttributes_default;
mnAttr.displayName = UA_LOCALIZEDTEXT("en-US", "ManufacturerName");
UA_NodeId manufacturerNameId;
UA_Server_addVariableNode(server, UA_NODEID_NULL, deviceTypeId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "ManufacturerName"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
mnAttr, NULL, &manufacturerNameId);
/* Make the manufacturer name mandatory */
UA_Server_addReference(server, manufacturerNameId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASMODELLINGRULE),
UA_EXPANDEDNODEID_NUMERIC(0, UA_NS0ID_MODELLINGRULE_MANDATORY), true);
UA_VariableAttributes modelAttr = UA_VariableAttributes_default;
modelAttr.displayName = UA_LOCALIZEDTEXT("en-US", "ModelName");
UA_Server_addVariableNode(server, UA_NODEID_NULL, deviceTypeId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "ModelName"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
modelAttr, NULL, NULL);
/* Define the object type for "Pump" */
UA_ObjectTypeAttributes ptAttr = UA_ObjectTypeAttributes_default;
ptAttr.displayName = UA_LOCALIZEDTEXT("en-US", "PumpType");
UA_Server_addObjectTypeNode(server, pumpTypeId,
deviceTypeId, UA_NODEID_NUMERIC(0, UA_NS0ID_HASSUBTYPE),
UA_QUALIFIEDNAME(1, "PumpType"), ptAttr,
NULL, NULL);
UA_VariableAttributes statusAttr = UA_VariableAttributes_default;
statusAttr.displayName = UA_LOCALIZEDTEXT("en-US", "Status");
statusAttr.valueRank = UA_VALUERANK_SCALAR;
UA_NodeId statusId;
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpTypeId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "Status"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
statusAttr, NULL, &statusId);
/* Make the status variable mandatory */
UA_Server_addReference(server, statusId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASMODELLINGRULE),
UA_EXPANDEDNODEID_NUMERIC(0, UA_NS0ID_MODELLINGRULE_MANDATORY), true);
UA_VariableAttributes rpmAttr = UA_VariableAttributes_default;
rpmAttr.displayName = UA_LOCALIZEDTEXT("en-US", "MotorRPM");
rpmAttr.valueRank = UA_VALUERANK_SCALAR;
UA_Server_addVariableNode(server, UA_NODEID_NULL, pumpTypeId,
UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT),
UA_QUALIFIEDNAME(1, "MotorRPMs"),
UA_NODEID_NUMERIC(0, UA_NS0ID_BASEDATAVARIABLETYPE),
rpmAttr, NULL, NULL);
}
/**
* Now we add the derived ObjectType for the pump that inherits from the device
* object type. The resulting object contains all mandatory child variables.
* These are simply copied over from the object type. The object has a reference
* of type ``hasTypeDefinition`` to the object type, so that clients can detect
* the type-instance relation at runtime.
*/
static void
addPumpObjectInstance(UA_Server *server, char *name) {
UA_ObjectAttributes oAttr = UA_ObjectAttributes_default;
oAttr.displayName = UA_LOCALIZEDTEXT("en-US", name);
UA_Server_addObjectNode(server, UA_NODEID_NULL,
UA_NODEID_NUMERIC(0, UA_NS0ID_OBJECTSFOLDER),
UA_NODEID_NUMERIC(0, UA_NS0ID_ORGANIZES),
UA_QUALIFIEDNAME(1, name),
pumpTypeId, /* this refers to the object type
identifier */
oAttr, NULL, NULL);
}
/**
* Often we want to run a constructor function on a new object. This is
* especially useful when an object is instantiated at runtime (with the
* AddNodes service) and the integration with an underlying process cannot be
* manually defined. In the following constructor example, we simply set the
* pump status to on.
*/
static UA_StatusCode
pumpTypeConstructor(UA_Server *server,
const UA_NodeId *sessionId, void *sessionContext,
const UA_NodeId *typeId, void *typeContext,
const UA_NodeId *nodeId, void **nodeContext) {
UA_LOG_INFO(UA_Log_Stdout, UA_LOGCATEGORY_USERLAND, "New pump created");
/* Find the NodeId of the status child variable */
UA_RelativePathElement rpe;
UA_RelativePathElement_init(&rpe);
rpe.referenceTypeId = UA_NODEID_NUMERIC(0, UA_NS0ID_HASCOMPONENT);
rpe.isInverse = false;
rpe.includeSubtypes = false;
rpe.targetName = UA_QUALIFIEDNAME(1, "Status");
UA_BrowsePath bp;
UA_BrowsePath_init(&bp);
bp.startingNode = *nodeId;
bp.relativePath.elementsSize = 1;
bp.relativePath.elements = &rpe;
UA_BrowsePathResult bpr =
UA_Server_translateBrowsePathToNodeIds(server, &bp);
if(bpr.statusCode != UA_STATUSCODE_GOOD ||
bpr.targetsSize < 1)
return bpr.statusCode;
/* Set the status value */
UA_Boolean status = true;
UA_Variant value;
UA_Variant_setScalar(&value, &status, &UA_TYPES[UA_TYPES_BOOLEAN]);
UA_Server_writeValue(server, bpr.targets[0].targetId.nodeId, value);
UA_BrowsePathResult_clear(&bpr);
/* At this point we could replace the node context .. */
return UA_STATUSCODE_GOOD;
}
static void
addPumpTypeConstructor(UA_Server *server) {
UA_NodeTypeLifecycle lifecycle;
lifecycle.constructor = pumpTypeConstructor;
lifecycle.destructor = NULL;
UA_Server_setNodeTypeLifecycle(server, pumpTypeId, lifecycle);
}
/** It follows the main server code, making use of the above definitions. */
int main(void) {
UA_Server *server = UA_Server_new();
manuallyDefinePump(server);
defineObjectTypes(server);
addPumpObjectInstance(server, "pump2");
addPumpObjectInstance(server, "pump3");
addPumpTypeConstructor(server);
addPumpObjectInstance(server, "pump4");
addPumpObjectInstance(server, "pump5");
UA_Server_runUntilInterrupt(server);
UA_Server_delete(server);
return 0;
}
|