File: FeatureXMLFile_3_old.featureXML

package info (click to toggle)
openms 1.11.1-5
  • links: PTS, VCS
  • area: main
  • in suites: jessie, jessie-kfreebsd
  • size: 436,688 kB
  • ctags: 150,907
  • sloc: cpp: 387,126; xml: 71,547; python: 7,764; ansic: 2,626; php: 2,499; sql: 737; ruby: 342; sh: 325; makefile: 128
file content (128 lines) | stat: -rw-r--r-- 7,000 bytes parent folder | download
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
<?xml version="1.0" encoding="ISO-8859-1"?>
<featureMap version="1.3" id="lsid" xsi:noNamespaceSchemaLocation="http://open-ms.sourceforge.net/schemas/FeatureXML_1_3.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
	<description>
		<admin>
			<sampleName>MS-Sample</sampleName>
			<sampleDescription>
				<cvParam cvLabel="psi" accession="PSI:1000001" name="SampleNumber" value="0-815"/>
				<cvParam cvLabel="psi" accession="PSI:1000003" name="SampleState" value="Gas"/>
				<cvParam cvLabel="psi" accession="PSI:1000004" name="SampleMass" value="1.01"/>
				<cvParam cvLabel="psi" accession="PSI:1000005" name="SampleVolume" value="2.02"/>
				<cvParam cvLabel="psi" accession="PSI:1000006" name="SampleConcentration" value="3.03"/>
				<userParam name="URL" value="www.open-ms.de"/>
				<userParam name="SampleComment" value="Sample"/>
			</sampleDescription>
			<sourceFile>
				<nameOfFile>MzDataFile_test_1.raw</nameOfFile>
				<pathToFile>/share/data/</pathToFile>
				<fileType>MS</fileType>
			</sourceFile>
			<contact>
				<name>John Doe</name>
				<institution>department 1</institution>
				<contactInfo>www.john.doe</contactInfo>
			</contact>
			<contact>
				<name>Jane Doe</name>
				<institution>department 2</institution>
				<contactInfo>www.jane.doe</contactInfo>
			</contact>
		</admin>
		<instrument>
			<instrumentName>MS-Instrument</instrumentName>
			<source>
				<cvParam cvLabel="psi" accession="PSI:1000007" name="InletType" value="Direct"/>
				<cvParam cvLabel="psi" accession="PSI:1000008" name="IonizationType" value="ESI"/>
				<cvParam cvLabel="psi" accession="PSI:1000009" name="IonizationMode" value="NegativeIonMode"/>
				<userParam name="URL" value="www.open-ms.de"/>
				<userParam name="SourceComment" value="Source"/>
			</source>
			<analyzerList count="2">
				<analyzer>
					<cvParam cvLabel="psi" accession="PSI:1000010" name="AnalyzerType" value="PaulIonTrap"/>
					<cvParam cvLabel="psi" accession="PSI:1000011" name="Resolution" value="22.33"/>
					<cvParam cvLabel="psi" accession="PSI:1000012" name="ResolutionMethod" value="FWHM"/>
					<cvParam cvLabel="psi" accession="PSI:1000013" name="ResolutionType" value="Constant"/>
					<cvParam cvLabel="psi" accession="PSI:1000014" name="Accuracy" value="33.44"/>
					<cvParam cvLabel="psi" accession="PSI:1000015" name="ScanRate" value="44.55"/>
					<cvParam cvLabel="psi" accession="PSI:1000016" name="ScanTime" value="55.66"/>
					<cvParam cvLabel="psi" accession="PSI:1000017" name="ScanFunction" value="MassScan"/>
					<cvParam cvLabel="psi" accession="PSI:1000018" name="ScanDirection" value="Up"/>
					<cvParam cvLabel="psi" accession="PSI:1000019" name="ScanLaw" value="Linear"/>
					<cvParam cvLabel="psi" accession="PSI:1000020" name="TandemScanningMethod" value="PrecursorIonScan"/>
					<cvParam cvLabel="psi" accession="PSI:1000021" name="ReflectronState" value="Off"/>
					<cvParam cvLabel="psi" accession="PSI:1000022" name="TOFTotalPathLength" value="66.77"/>
					<cvParam cvLabel="psi" accession="PSI:1000023" name="IsolationWidth" value="77.88"/>
					<cvParam cvLabel="psi" accession="PSI:1000024" name="FinalMSExponent" value="2"/>
					<cvParam cvLabel="psi" accession="PSI:1000025" name="MagneticFieldStrength" value="88.99"/>
					<userParam name="URL" value="www.open-ms.de"/>
					<userParam name="AnalyzerComment" value="Analyzer 1"/>
				</analyzer>
				<analyzer>
					<cvParam cvLabel="psi" accession="PSI:1000010" name="AnalyzerType" value="Quadrupole"/>
					<cvParam cvLabel="psi" accession="PSI:1000011" name="Resolution" value="12.3"/>
					<cvParam cvLabel="psi" accession="PSI:1000012" name="ResolutionMethod" value="Baseline"/>
					<cvParam cvLabel="psi" accession="PSI:1000013" name="ResolutionType" value="Proportional"/>
					<cvParam cvLabel="psi" accession="PSI:1000014" name="Accuracy" value="13.4"/>
					<cvParam cvLabel="psi" accession="PSI:1000015" name="ScanRate" value="14.5"/>
					<cvParam cvLabel="psi" accession="PSI:1000016" name="ScanTime" value="15.6"/>
					<cvParam cvLabel="psi" accession="PSI:1000017" name="ScanFunction" value="SelectedIonDetection"/>
					<cvParam cvLabel="psi" accession="PSI:1000018" name="ScanDirection" value="Down"/>
					<cvParam cvLabel="psi" accession="PSI:1000019" name="ScanLaw" value="Exponential"/>
					<cvParam cvLabel="psi" accession="PSI:1000020" name="TandemScanningMethod" value="ProductIonScan"/>
					<cvParam cvLabel="psi" accession="PSI:1000021" name="ReflectronState" value="On"/>
					<cvParam cvLabel="psi" accession="PSI:1000022" name="TOFTotalPathLength" value="16.7"/>
					<cvParam cvLabel="psi" accession="PSI:1000023" name="IsolationWidth" value="17.8"/>
					<cvParam cvLabel="psi" accession="PSI:1000024" name="FinalMSExponent" value="-2"/>
					<cvParam cvLabel="psi" accession="PSI:1000025" name="MagneticFieldStrength" value="18.9"/>
					<userParam name="URL" value="www.open-ms.de"/>
					<userParam name="AnalyzerComment" value="Analyzer 2"/>
				</analyzer>
			</analyzerList>
			<detector>
				<cvParam cvLabel="psi" accession="PSI:1000026" name="DetectorType" value="FaradayCup"/>
				<cvParam cvLabel="psi" accession="PSI:1000027" name="DetectorAcquisitionMode" value="TDC"/>
				<cvParam cvLabel="psi" accession="PSI:1000028" name="DetectorResolution" value="0.815"/>
				<cvParam cvLabel="psi" accession="PSI:1000029" name="ADCSamplingFrequency" value="11.22"/>
				<userParam name="URL" value="www.open-ms.de"/>
				<userParam name="DetectorComment" value="Detector"/>
			</detector>
			<additional>
				<cvParam cvLabel="psi" accession="PSI:1000030" name="Vendor" value="MS-Vendor"/>
				<cvParam cvLabel="psi" accession="PSI:1000031" name="Model" value="MS 1"/>
				<cvParam cvLabel="psi" accession="PSI:1000032" name="Customization" value="tuned"/>
				<userParam name="URL" value="www.open-ms.de"/>
				<userParam name="AdditionalComment" value="Additional"/>
			</additional>
		</instrument>
		<dataProcessing>
			<software completionTime="2001-02-03T04:05:06">
				<name>MS-X</name>
				<version>1.0</version>
				<comments>none</comments>
			</software>
			<processingMethod>
				<cvParam cvLabel="psi" name="Deisotoping" accession="PSI:1000033" value="false"/>
				<cvParam cvLabel="psi" name="ChargeDeconvolution" accession="PSI:1000034" value="false"/>
				<cvParam cvLabel="psi" accession="PSI:1000035" name="PeakProcessing" value="CentroidMassSpectrum"/>
				<userParam name="URL" value="www.open-ms.de"/>
				<userParam name="ProcessingComment" value="Processed"/>
			</processingMethod>
		</dataProcessing>
	</description>
	<featureList count="1">
		<feature id="f_0">
			<position dim="0">25</position>
			<position dim="1">0</position>
			<intensity>300</intensity>
			<quality dim="0">0</quality>
			<quality dim="1">0</quality>
			<overallquality>0</overallquality>
			<charge>0</charge>
			<model name="OlesModel">
				<param name="a" value="5"/>
				<param name="b" value="10"/>
			</model>
		</feature>
	</featureList>
</featureMap>